Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 110(1-4): 129-34, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353635

RESUMO

The neutron energy spectrum of the JRC 241Am-Li(alpha,n) radionuclide source has been measured at the PTB in Germany using various spectrometry systems, such as Bonner spheres, proton recoil counters and NE213 liquid scintillators. The source photon spectrum has been measured and the neutron contamination due to traces of beryllium through the 9Be(alpha,n)12C reaction has been determined. The effects associated with source encapsulation and the materials it contains have been investigated previously, using Monte Carlo simulations, the various structures seen in the spectra have been explained and the anisotropy of fluence distributions in 4pi have been calculated and compared to measurements. These extensive high resolution spectrometry measurements have been coupled to Monte Carlo calculations to provide a realistic spectrum and new spectrum-averaged fluence-to-dose equivalent conversion coefficients for the actual 241Am-Li source.


Assuntos
Amerício/análise , Lítio/análise , Nêutrons , Proteção Radiológica/métodos , Proteção Radiológica/normas , Radiometria/métodos , Radiometria/normas , Carga Corporal (Radioterapia) , Calibragem/normas , Simulação por Computador , Desenho Assistido por Computador , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas , Alemanha , Internacionalidade , Modelos Estatísticos , Método de Monte Carlo , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Doses de Radiação , Proteção Radiológica/instrumentação , Radioisótopos/análise , Radiometria/instrumentação , Padrões de Referência , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
2.
Radiat Prot Dosimetry ; 110(1-4): 523-7, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353702

RESUMO

The new CANEL/T400 facility has been set-up at the Institute for Radiological Protection and Nuclear Safety (IRSN) to produce a realistic neutron field. The accurate characterisation of this neutron field is mandatory since this facility will be used as a reference neutron source. For this reason an international measuring campaign, involving four laboratories with extensive expertise in neutron metrology and spectrometry, was organised through a concerted EUROMET project. Measurements were performed with Bonner sphere (BS) systems to determine the energy distribution of the emitted neutrons over the whole energy range (from thermal energy up to a few MeV). Additional measurements were performed with proton recoil detectors to provide detailed information in the energy region above 90 keV. The results obtained by the four laboratories are in agreement with each other and are compared with a calculation performed with the MCNP4C Monte-Carlo code. As a conclusion of this exercise, a reliable characterisation of the CANEL/T400 neutron field is obtained.


Assuntos
Calibragem/normas , Análise de Falha de Equipamento/normas , Nêutrons , Proteção Radiológica/instrumentação , Proteção Radiológica/normas , Radiometria/instrumentação , Radiometria/normas , Algoritmos , Carga Corporal (Radioterapia) , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Europa (Continente) , Estudos de Viabilidade , Humanos , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Padrões de Referência , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Medição de Risco/métodos , Medição de Risco/normas , Fatores de Risco , Sensibilidade e Especificidade