Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 2024 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-39472104

RESUMO

Here we report the application of chemometric analysis for modeling absorbance spectroscopy and fluorescence emission data from a resazurin-based assay targeting low-level bacterial detection in biofluids. Bacteria spiked samples were incubated with resazurin and absorbance and fluorescence data were collected at 30 min intervals. The absorbance data was subjected to Principal Component Analysis (PCA) and Partial Least Squares Regression (PLSR) and compared with the univariate fluorescence spectroscopy approach. The analysis demonstrated the multidimensional nature of the absorbance data, highlighting the appearance of the resorufin peak at the 2 h time point with a low bacterial inoculum of 0.01 CFU mL-1 across all the samples tested-water, urine and serum. The PLSR models supported the PCA data and exhibited strong predictive capabilities for water (RC2 = 0.937, RCV2 = 0.934), urine (RC2 = 0.899, RCV2 = 0.880) and serum (RC2 = 0.985, RCV2 = 0.967). Conversely, fluorescence is contingent upon resorufin existence, necessitating a prolonged waiting period postincubation with resazurin to verify the presence of bacteria, especially when contamination levels are low. Given the substantial global impact of bacteria-related infections, this method detects bacteria at low concentrations precisely and rapidly, improving efficiency and adaptability for point-of-care settings, promising swift diagnosis of bacterial infections, environmental monitoring, or food-quality control.

2.
Anal Chem ; 2024 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-39496348

RESUMO

The rapid and accurate identification of pathogenic bacteria is crucial for combating the growing threat of antibiotic resistance, nosocomial infections, and food safety concerns. This study presents a novel and comprehensive comparison of two vibrational spectroscopic techniques - attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and a low-cost miniature near-infrared (NIR) spectrometer - for distinguishing Gram-positive and Gram-negative bacterial samples grown using the same stock media solution. This is the first report of NIR spectroscopy being applied to differentiate Gram-positive and Gram-negative bacteria, as well as the first direct comparison of ATR-FTIR and NIR for the combined multimodal analysis of clinical bacterial isolates. Using a data set of five Gram-positive and seven Gram-negative species and recording spectra in triplicate, the study employed advanced data fusion and multivariate analysis techniques to classify the spectra and facilitate NIR band assignment. 2D correlation analysis revealed strong positive correlations between key spectral markers identified in both modalities. Partial least-squares- and support vector machine discriminant analysis models were validated using a methodology based on 100 repeated random sampling of calibration and test sets. Models demonstrated that both the standalone ATR-FTIR and the combined ATR-FTIR/NIR approach achieved exceptional classification accuracy (>98%) in differentiating the two bacterial groups. Differences observed in the spectra were attributed to the distinct cell wall compositions of Gram-Positive and Gram-negative bacteria. Notably, the low-cost NIR technique also showed promising performance, with classification accuracy values above 90%. The findings highlight the potential of these rapid, noninvasive, and cost-effective vibrational spectroscopic techniques, particularly the NIR method, for point-of-care applications in clinical microbiology and food safety monitoring. The combination of ATR-FTIR and NIR data further enhances the robustness and reliability of bacterial identification, paving the way for broader adoption of these advanced analytical tools in various healthcare and food safety settings.

3.
Anal Chem ; 95(8): 3986-3995, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36787387

RESUMO

The prevalence of neglected tropical diseases (NTDs) is advancing at an alarming rate. The NTD leishmaniasis is now endemic in over 90 tropical and sub-tropical low socioeconomic countries. Current diagnosis for this disease involves serological assessment of infected tissue by either light microscopy, antibody tests, or culturing with in vitro or in vivo animal inoculation. Furthermore, co-infection by other pathogens can make it difficult to accurately determine Leishmania infection with light microscopy. Herein, for the first time, we demonstrate the potential of combining synchrotron Fourier-transform infrared (FTIR) microspectroscopy with powerful discrimination tools, such as partial least squares-discriminant analysis (PLS-DA), support vector machine-discriminant analysis (SVM-DA), and k-nearest neighbors (KNN), to characterize the parasitic forms of Leishmania major both isolated and within infected macrophages. For measurements performed on functional infected and uninfected macrophages in physiological solutions, the sensitivities from PLS-DA, SVM-DA, and KNN classification methods were found to be 0.923, 0.981, and 0.989, while the specificities were 0.897, 1.00, and 0.975, respectively. Cross-validated PLS-DA models on live amastigotes and promastigotes showed a sensitivity and specificity of 0.98 in the lipid region, while a specificity and sensitivity of 1.00 was achieved in the fingerprint region. The study demonstrates the potential of the FTIR technique to identify unique diagnostic bands and utilize them to generate machine learning models to predict Leishmania infection. For the first time, we examine the potential of infrared spectroscopy to study the molecular structure of parasitic forms in their native aqueous functional state, laying the groundwork for future clinical studies using more portable devices.


Assuntos
Leishmania major , Leishmaniose , Animais , Síncrotrons , Espectrofotometria Infravermelho , Leishmaniose/diagnóstico , Macrófagos/parasitologia
4.
Analyst ; 148(7): 1595-1602, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36897283

RESUMO

Oxidative treatment of human red blood cells (RBCs) prior to freeze-drying appears to stabilize the RBCs to withstand dried storage at room temperature. To better understand the effects of oxidation and freeze-drying/rehydration on RBC lipids and proteins, single-cell measurements were performed by synchrotron-based Fourier transform infrared (FTIR) microspectroscopy 'live-cell' (unfixed) analysis. Lipid and protein spectral data of tert-butyl hydroperoxide (TBHP)-oxidized RBCs (oxRBCs), FDoxRBCs and control (untreated) RBCs were compared using principal component analysis (PCA) and band integration ratios. The oxRBCs and FDoxRBCs samples had similar spectral profiles that were clearly different to control RBCs. Spectral changes in the CH stretching region of oxRBCs and FDoxRBCs indicated the presence of increased saturated and shorter-chain lipids, consistent with lipid peroxidation and stiffening of the RBC membrane compared to control RBCs. The PCA loadings plot for the fingerprint region of control RBCs corresponding to the α-helical structure of hemoglobin, shows that oxRBCs and FDoxRBCs have conformational changes in the protein secondary structure to ß-pleated sheets and ß-turns. Finally, the freeze-drying process did not appear to compound or induce additional changes. In this context, FDoxRBCs could become a stable source of reagent RBCs for pre-transfusion blood serology testing. The synchrotron FTIR microspectroscopic live-cell protocol provides a powerful analytical tool to characterize and contrast the effects of different treatments on RBC chemical composition at the single cell level.


Assuntos
Eritrócitos , Síncrotrons , Humanos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise de Fourier , Lipídeos/química
5.
Analyst ; 147(12): 2662-2670, 2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35611958

RESUMO

Malaria was regarded as the most devastating infectious disease of the 21st century until the COVID-19 pandemic. Asexual blood staged parasites (ABS) play a unique role in ensuring the parasite's survival and pathogenesis. Hitherto, there have been no spectroscopic reports discriminating the life cycle stages of the ABS parasite under physiological conditions. The identification and quantification of the stages in the erythrocytic life cycle is important in monitoring the progression and recovery from the disease. In this study, we explored visible microspectrophotometry coupled to machine learning to discriminate functional ABS parasites at the single cell level. Principal Component Analysis (PCA) showed an excellent discrimination between the different stages of the ABS parasites. Support Vector Machine Analysis provided a 100% prediction for both schizonts and trophozoites, while a 92% and 98% accuracy was achieved for predicting control and ring staged infected RBCs, respectively. This work shows proof of principle for discriminating the life cycle stages of parasites in functional erythrocytes using visible microscopy and thus eliminating the drying and fixative steps that are associated with other optical-based spectroscopic techniques.


Assuntos
COVID-19 , Malária Falciparum , Malária , Parasitos , Animais , Eritrócitos/parasitologia , Humanos , Estágios do Ciclo de Vida , Aprendizado de Máquina , Microespectrofotometria , Pandemias , Plasmodium falciparum/fisiologia
6.
Sensors (Basel) ; 22(12)2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35746311

RESUMO

Serum is an important candidate in proteomics analysis as it potentially carries key markers on health status and disease progression. However, several important diagnostic markers found in the circulatory proteome and the low-molecular-weight (LMW) peptidome have become analytically challenging due to the high dynamic concentration range of the constituent protein/peptide species in serum. Herein, we propose a novel approach to improve the limit of detection (LoD) of LMW amino acids by combining mid-IR (MIR) and near-IR spectroscopic data using glycine as a model LMW analyte. This is the first example of near-IR spectroscopy applied to elucidate the detection limit of LMW components in serum; moreover, it is the first study of its kind to combine mid-infrared (25-2.5 µm) and near-infrared (2500-800 nm) to detect an analyte in serum. First, we evaluated the prediction model performance individually with MIR (ATR-FTIR) and NIR spectroscopic methods using partial least squares regression (PLS-R) analysis. The LoD was found to be 0.26 mg/mL with ATR spectroscopy and 0.22 mg/mL with NIR spectroscopy. Secondly, we examined the ability of combined spectral regions to enhance the detection limit of serum-based LMW amino acids. Supervised extended wavelength PLS-R resulted in a root mean square error of prediction (RMSEP) value of 0.303 mg/mL and R2 value of 0.999 over a concentration range of 0-50 mg/mL for glycine spiked in whole serum. The LoD improved to 0.17 mg/mL from 0.26 mg/mL. Thus, the combination of NIR and mid-IR spectroscopy can improve the limit of detection for an LMW compound in a complex serum matrix.


Assuntos
Glicina , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Análise dos Mínimos Quadrados , Espectrofotometria Infravermelho , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos
7.
Anal Chem ; 93(13): 5451-5458, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33759513

RESUMO

New point-of-care diagnostic approaches for malaria that are sensitive to low parasitemia, easy to use in a field setting, and affordable are urgently required to meet the World Health Organization's objective of reducing malaria cases and related life losses by 90% globally on or before 2030. In this study, an inexpensive "matchbox size" near-infrared (NIR) spectrophotometer was used for the first time to detect and quantify malaria infection in vitro from isolated dried red blood cells using a fingerpick volume of blood. This the first study to apply a miniaturized NIR device to diagnose a parasitic infection and identify marker bands indicative of malaria infection in the NIR region. An NIR device has many advantages including wavelength accuracy and repeatability, speed, resolution, and a greatly improved signal-to-noise ratio compared to existing spectroscopic options. Using multivariate data analysis, we discriminated control red blood cells from infected cells and established the limit of detection of the technique. Principal component analysis displayed a good separation between the infected and uninfected RBCs, while partial least-squares regression analysis yielded a robust parasitemia prediction with root-mean-square error of prediction values of 0.446 and 0.001% for the higher and lower parasitemia models, respectively. The R2 values of the higher and lower parasitemia models were 0.947 and 0.931, respectively. Finally, an estimated parasitemia detection limit of 0.00001% and a qunatification limit of 0.001% was achieved; to ascertain the true efficacy of the technique for point-of-care screening, clinical studies using large patient numbers are required, which is the subject of future studies.


Assuntos
Malária , Parasitemia , Eritrócitos , Humanos , Análise dos Mínimos Quadrados , Malária/diagnóstico , Parasitemia/diagnóstico , Análise de Componente Principal
8.
Anal Chem ; 93(39): 13302-13310, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34558904

RESUMO

The scourge of malaria infection continues to strike hardest against pregnant women and children in Africa and South East Asia. For global elimination, testing methods that are ultrasensitive to low-level ring-staged parasitemia are urgently required. In this study, we used a novel approach for diagnosis of malaria infection by combining both electronic ultraviolet-visible (UV/vis) spectroscopy and near infrared (NIR) spectroscopy to detect and quantify low-level (1-0.000001%) ring-staged malaria-infected whole blood under physiological conditions uisng Multiclass classification using logistic regression, which showed that the best results were achieved using the extended wavelength range, providing an accuracy of 100% for most parasitemia classes. Likewise, partial least-squares regression (PLS-R) analysis showed a higher quantification sensitivity (R2 = 0.898) for the extended spectral region compared to UV/vis and NIR (R2 = 0.806 and 0.556, respectively). For quantifying different-stage blood parasites, the extended wavelength range was able to detect and quantify all thePlasmodium falciparum accurately compared to testing each spectral component separately. These results demonstrate the potential of a combined UV/vis-NIR spectroscopy to accurately diagnose malaria-infected patients without the need for elaborate sample preparation associated with the existing mid-IR approaches.


Assuntos
Malária , Parasitemia , Feminino , Humanos , Malária/diagnóstico , Parasitemia/diagnóstico , Gravidez , Espectroscopia de Luz Próxima ao Infravermelho
9.
Anal Chem ; 93(36): 12187-12194, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34459578

RESUMO

Spectral histopathology has shown promise for the classification and diagnosis of tumors with defined morphology, but application in tumors with variable or diffuse morphologies is yet to be investigated. To address this gap, we evaluated the application of Fourier transform infrared (FTIR) imaging as an accessory diagnostic tool for canine hemangiosarcoma (HSA), a vascular endothelial cell cancer that is difficult to diagnose. To preserve the delicate vascular tumor tissue structure, and potential classification of single endothelial cells, paraffin removal was not performed, and a partial least square discrimination analysis (PLSDA) and Random Forest (RF) models to classify different tissue types at individual pixel level were established using a calibration set (24 FTIR images from 13 spleen specimens). Next, the prediction capability of the PLSDA model was tested with an independent test set (n = 11), resulting in 74% correct classification of different tissue types at an individual pixel level. Finally, the performance of the FTIR spectropathology and chemometric algorithm for diagnosis of HSA was established in a blinded set of tissue samples (n = 24), with sensitivity and specificity of 80 and 81%, respectively. Taken together, these results show that FTIR imaging without paraffin removal can be applied to tumors with diffuse morphology, and this technique is a promising tool to assist in canine splenic HSA differential diagnosis.


Assuntos
Hemangiossarcoma , Animais , Cães , Células Endoteliais , Hemangiossarcoma/diagnóstico por imagem , Hemangiossarcoma/veterinária , Análise dos Mínimos Quadrados , Espectroscopia de Infravermelho com Transformada de Fourier , Baço
10.
Analyst ; 146(14): 4709, 2021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34136888

RESUMO

Correction for 'Synchrotron macro ATR-FTIR microspectroscopy for high-resolution chemical mapping of single cells' by Jitraporn Vongsvivut et al., Analyst, 2019, 144, 3226-3238, DOI: 10.1039/C8AN01543K.

11.
Nucleic Acids Res ; 47(18): e108, 2019 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-31562528

RESUMO

The integrity of the chromatin structure is essential to every process occurring within eukaryotic nuclei. However, there are no reliable tools to decipher the molecular composition of metaphase chromosomes. Here, we have applied infrared nanospectroscopy (AFM-IR) to demonstrate molecular difference between eu- and heterochromatin and generate infrared maps of single metaphase chromosomes revealing detailed information on their molecular composition, with nanometric lateral spatial resolution. AFM-IR coupled with principal component analysis has confirmed that chromosome areas containing euchromatin and heterochromatin are distinguishable based on differences in the degree of methylation. AFM-IR distribution of eu- and heterochromatin was compared to standard fluorescent staining. We demonstrate the ability of our methodology to locate spatially the presence of anticancer drug sites in metaphase chromosomes and cellular nuclei. We show that the anticancer 'rule breaker' platinum compound [Pt[N(p-HC6F4)CH2]2py2] preferentially binds to heterochromatin, forming localized discrete foci due to condensation of DNA interacting with the drug. Given the importance of DNA methylation in the development of nearly all types of cancer, there is potential for infrared nanospectroscopy to be used to detect gene expression/suppression sites in the whole genome and to become an early screening tool for malignancy.


Assuntos
Cromossomos/ultraestrutura , DNA/ultraestrutura , Metáfase/genética , Espectrofotometria Infravermelho/métodos , Animais , Núcleo Celular/ultraestrutura , Eucromatina/ultraestrutura , Heterocromatina/ultraestrutura , Humanos , Interfase/genética
12.
Angew Chem Int Ed Engl ; 60(31): 17102-17107, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34043272

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in an unprecedented need for diagnostic testing that is critical in controlling the spread of COVID-19. We propose a portable infrared spectrometer with purpose-built transflection accessory for rapid point-of-care detection of COVID-19 markers in saliva. Initially, purified virion particles were characterized with Raman spectroscopy, synchrotron infrared (IR) and AFM-IR. A data set comprising 171 transflection infrared spectra from 29 subjects testing positive for SARS-CoV-2 by RT-qPCR and 28 testing negative, was modeled using Monte Carlo Double Cross Validation with 50 randomized test and model sets. The testing sensitivity was 93 % (27/29) with a specificity of 82 % (23/28) that included positive samples on the limit of detection for RT-qPCR. Herein, we demonstrate a proof-of-concept high throughput infrared COVID-19 test that is rapid, inexpensive, portable and utilizes sample self-collection thus minimizing the risk to healthcare workers and ideally suited to mass screening.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Saliva/química , Animais , Chlorocebus aethiops , Estudos de Coortes , Análise Discriminante , Humanos , Análise dos Mínimos Quadrados , Método de Monte Carlo , Testes Imediatos , Estudo de Prova de Conceito , SARS-CoV-2 , Sensibilidade e Especificidade , Manejo de Espécimes , Espectrofotometria Infravermelho , Células Vero
13.
Anal Chem ; 92(23): 15361-15369, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33170647

RESUMO

Cholangiocarcinoma (CCA) is a bile duct cancer that originates in the bile duct epithelium. Northeastern Thailand has the highest incidence of CCA, and there is a direct correlation with liver fluke (Opisthorchis viverrini) infection. The high mortality rate of CCA is a consequence of delayed diagnosis. Fourier transform infrared (FTIR) spectroscopy is a powerful technique that detects the absorbance of molecular vibrations and is perfectly suited for the interrogation of biological samples. In this study, we applied synchrotron radiation-FTIR (SR-FTIR) microspectroscopy and focal plane array (FPA-FTIR) microspectroscopy to characterize periductal fibrosis and bile duct cells progressing to CCA induced by inoculating O. viverrini metacercariae into hamsters. SR-FTIR and FPA-FTIR measurements were performed in liver sections harvested from 1-, 2-, 3-, and 6-month post-infected hamsters compared to uninfected liver tissues. Principal component analysis (PCA) of the tissue samples showed a clear discrimination among uninfected and early-stage (1 and 2 months) and cancerous-stage (3 and 6 months) tissues. The discrimination is based on intensity changes in the phosphodiester band (1081 cm-1), amino acid residue (∼1396 cm-1), and C═O stretching carboxylic esters (1745 cm-1). Infected tissues also show definitive bands at ∼1280, 1234, and 1201 cm-1 characteristic of the collagen triplet and indicative of fibrosis. Hierarchical cluster analysis (HCA) was performed on the FPA data and showed a classification into specific cell types. Hepatocyte, fibrotic lesion, and bile duct (cancer) were classified and HCA mapping showed similar cellular distribution pattern compared to Sirius red staining. This study was also extended to less invasive sample analysis using attenuated total reflectance-FTIR (ATR-FTIR) spectroscopy. Sera from O. viverrini-infected and uninfected hamsters were analyzed using multivariate analysis, including principal component analysis (PCA), and partial least squares-discriminant analysis (PLS-DA). PCA was able to classify spectra of normal, early-stage CCA, and CCA, while the PLS-DA gave 100% accuracy for the validation. The model was established from 17 samples (11 normal, 6 cancer) in the calibration set and 9 samples in the validation set (4 normal, 2 cancer, 3 precancerous). These results indicate that FTIR-based technology is a potential tool to detect the progression of CCA, especially in the early stages of the disease.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico por imagem , Colangiocarcinoma/diagnóstico por imagem , Progressão da Doença , Fasciola hepatica/fisiologia , Imagem Óptica/instrumentação , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Síncrotrons , Animais , Neoplasias dos Ductos Biliares/etiologia , Neoplasias dos Ductos Biliares/patologia , Colangiocarcinoma/etiologia , Colangiocarcinoma/patologia , Cricetinae , Modelos Animais de Doenças
14.
Anal Chem ; 92(13): 8784-8792, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32478508

RESUMO

Babesia bovis parasites present a serious and significant health concern for the beef and dairy industries in many parts of the world. Difficulties associated with the current diagnostic techniques include the following: they are prone to human error (microscopy) or expensive and time-consuming (polymerase chain reaction) to perform. Little is known about the biochemical changes in blood that are associated with Babesia infections. The discovery of new biomarkers will lead to improved diagnostic outcomes for the cattle industry. Vibrational spectroscopic technologies can record a chemical snapshot of the entire organism and the surrounding cell thereby providing a phenotype of the organism and the host infected cell. Here, we demonstrate the applicability of vibrational spectroscopic imaging techniques including Atomic Force Microscopy Infrared (AFM-IR) and confocal Raman microscopy to discover new biomarkers for B. bovis infections. Furthermore, we applied Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) to detect B. bovis in red blood cells (RBCs). Based on changes in the IR spectral bands, with ATR-FTIR in combination with Partial Least Squares-Discriminant Analysis we were able to discriminate infected samples from controls with a sensitivity and specificity of 92.0% and 91.7%, respectively, in less than 2 min, excluding sample extraction and preparation. The proposed method utilized a lysis approach to remove hemoglobin from the suspension of infected and uninfected cells, which significantly increased the sensitivity and specificity compared to measurements performed on intact infected red blood cells (intact infected RBC, 77.3% and 79.2%). This work represents a holistic spectroscopic study from the level of the single infected RBC using AFM-IR and confocal Raman to the detection of the parasite in a cell population using ATR-FTIR for a babesiosis diagnostic.


Assuntos
Babesia bovis/química , Babesiose/diagnóstico , Doenças dos Bovinos/diagnóstico , Espectrofotometria Infravermelho/métodos , Análise Espectral Raman/métodos , Animais , Babesia bovis/isolamento & purificação , Babesiose/parasitologia , Biomarcadores/química , Bovinos , Doenças dos Bovinos/parasitologia , Análise Discriminante , Eritrócitos/parasitologia , Análise dos Mínimos Quadrados , Microscopia de Força Atômica , Microscopia Confocal
15.
Anal Chem ; 92(12): 8235-8243, 2020 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32407103

RESUMO

Here, we applied vibrational spectroscopy to investigate the drug response following incubation of S. aureus with oxacillin. The main focus of this work was to identify the chemical changes caused by oxacillin over time and to determine the feasibility of the spectroscopic approach to detect antimicrobial resistance. The oxacillin-induced changes in the chemical composition of susceptible bacteria, preceding (and leading to) the inhibition of growth, included an increase in the relative content of nucleic acids, alteration in the α-helical/ß-sheet protein ratio, structural changes in carbohydrates (observed via changes in the band at 1035 cm-1), and significant thickening of the cell wall. These observations enabled a dose-dependent discrimination between susceptible bacteria incubated with and without oxacillin after 120 min. In methicillin resistant strains, no spectral differences were observed between cells, regardless of drug exposure. These results pave the way for a new, rapid spectroscopic approach to detect drug resistance in pathogens, based on their early positive/negative drug response.


Assuntos
Antibacterianos/análise , Antibacterianos/farmacologia , Resistência Microbiana a Medicamentos/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Staphylococcus aureus/efeitos dos fármacos
16.
Analyst ; 145(5): 1749-1758, 2020 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-31913373

RESUMO

A new type of aggregate, formed in human red blood cells (RBCs) in response to glutaraldehyde treatment, was discovered and analyzed with the classical and advanced biomolecular imaging techniques. Advanced Heinz body-like aggregates (AHBA) formed in a single human RBC are characterized by a higher level of hemoglobin (Hb) degradation compared to typical Heinz bodies, which consist of hemichromes. The complete destruction of the porphyrin structure of Hb and the aggregation of the degraded proteins in the presence of Fe3+ ions are observed. The presence of such aggregated, highly degraded proteins inside RBCs, without cell membrane destruction, has been never reported before. For the first time the spatial differentiation of two kinds of protein mixtures inside a single RBC, with different phenylalanine (Phe) conformations, is visualized. The non-resonant Raman spectra of altered RBCs with AHBA are characterized by the presence of a strong band located at 1037 cm-1, which confirms that glutaraldehyde interacts strongly with Phe. The shape-shifting of RBCs from a biconcave disk to a spherical structure and sinking of AHBA to the bottom of the cell are observed. Results reveal that the presence of AHBA should be considered when fixing RBCs and indicate the analytical potential of Raman spectroscopy, atomic force microscopy and scanning near-field optical microscopy in AHBA detection and analysis.


Assuntos
Citoesqueleto/metabolismo , Corpos de Heinz/patologia , Glutaral/toxicidade , Corpos de Heinz/ultraestrutura , Heme/metabolismo , Hemoglobinas/metabolismo , Humanos , Masculino , Agregados Proteicos/fisiologia
17.
Chem Rev ; 118(11): 5330-5358, 2018 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-29676564

RESUMO

New technologies to diagnose malaria at high sensitivity and specificity are urgently needed in the developing world where the disease continues to pose a huge burden on society. Infrared and Raman spectroscopy-based diagnostic methods have a number of advantages compared with other diagnostic tests currently on the market. These include high sensitivity and specificity for detecting low levels of parasitemia along with ease of use and portability. Here, we review the application of vibrational spectroscopic techniques for monitoring and detecting malaria infection. We discuss the role of vibrational (infrared and Raman) spectroscopy in understanding the processes of parasite biology and its application to the study of interactions with antimalarial drugs. The distinct molecular phenotype that characterizes malaria infection and the high sensitivity enabling detection of low parasite densities provides a genuine opportunity for vibrational spectroscopy to become a front-line tool in the elimination of this deadly disease and provide molecular insights into the chemistry of this unique organism.


Assuntos
Malária/diagnóstico , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Espectral Raman/métodos , Animais , Eritrócitos/microbiologia , Eritrócitos/patologia , Heme/análise , Hemeproteínas/análise , Humanos , Plasmodium/crescimento & desenvolvimento , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Análise Espectral Raman/instrumentação , Vibração
18.
Sensors (Basel) ; 20(12)2020 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-32570941

RESUMO

Bacterial growth in batch cultures occurs in four phases (lag, exponential/log, stationary and death phase) that differ distinctly in number of different bacteria, biochemistry and physiology. Knowledge regarding the growth phase and its kinetics is essential for bacterial research, especially in taxonomic identification and monitoring drug interactions. However, the conventional methods by which to assess microbial growth are based only on cell counting or optical density, without any insight into the biochemistry of cells or processes. Both Raman and Fourier transform infrared (FTIR) spectroscopy have shown potential to determine the chemical changes occurring between different bacterial growth phases. Here, we extend the application of spectroscopy and for the first time combine both Raman and FTIR microscopy in a multimodal approach to detect changes in the chemical compositions of bacteria within the same phase (intra-phase). We found a number of spectral markers associated with nucleic acids (IR: 964, 1082, 1215 cm-1; RS: 785, 1483 cm-1), carbohydrates (IR: 1035 cm-1; RS: 1047 cm-1) and proteins (1394 cm-1, amide II) reflecting not only inter-, but also intra-phase changes in bacterial chemistry. Principal component analysis performed simultaneously on FTIR and Raman spectra enabled a clear-cut, time-dependent discrimination between intra-lag phase bacteria probed every 30 min. This demonstrates the unique capability of multimodal vibrational spectroscopy to probe the chemistry of bacterial growth even at the intra-phase level, which is particularly important for the lag phase, where low bacterial numbers limit conventional analytical approaches.


Assuntos
Bactérias , Carboidratos , Proteínas , Bactérias/crescimento & desenvolvimento , Análise de Componente Principal , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Vibração
19.
Molecules ; 25(7)2020 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-32231044

RESUMO

Several studies have investigated the capacity of ATR-FTIR spectroscopy for fungal species discrimination. However, preparation methods vary among studies. This study aims to ascertain the effect of sample preparation on the discriminatory capacity of ATR-FTIR spectroscopy. Candida species were streaked to obtain colonies and spectra were collected from each preparation type, which included: (a) untreated colonies being directly transferred to the ATR crystal, (b) following washing and (c) following 24-h fixation in formalin. Spectra were pre-processed and principal component analysis (PCA) and K-means cluster analysis (KMC) were performed. Results showed that there was a clear discrimination between preparation types. Groups of spectra from untreated and washed isolates clustered separately due to intense protein, DNA and polysaccharide bands, whilst fixed spectra clustered separately due to intense polysaccharide bands. This signified that sample preparation had influenced the chemical composition of samples. Nevertheless, across preparation types, significant species discrimination was observed, and the polysaccharide (1200-900 cm-1) region was a common critical marker for species discrimination. However, different discriminatory marker bands were observed across preparation methods. Thus, sample preparation appears to influence the chemical composition of Candida samples; however, does not seem to significantly impact the species discrimination potential for ATR-FTIR spectroscopy.


Assuntos
Candida/química , Candida/classificação , Espectroscopia de Infravermelho com Transformada de Fourier , Análise por Conglomerados , Análise de Componente Principal
20.
Anal Chem ; 91(24): 15397-15403, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31755705

RESUMO

The development of antimicrobial resistance (AMR) resulting from widespread antibiotic usage is occurring at an alarming pace, much faster than our understanding of the mechanisms behind resistance. Knowledge about resistance-related phenotypic and genotypic changes is critical for the development of new drugs. Here, we identify changes in the chemical composition of Staphylococcus aureus associated with the development of resistance to last resort drugs, vancomycin and daptomycin, using a novel, single cell, nanoscale technique, atomic force microscopy-infrared spectroscopy (AFM-IR), combined with chemometric analysis. We utilized paired clinical isolates, with the parent (susceptible) strain isolated prior to treatment and the daughter (resistant) strain obtained from the same patient after drug admission and clinical failure. We observed an increase in the amount of nonintracellular carbohydrates, indicating thickening or changes in the packing of the cell wall, as well as changes in the phospholipid content in relation to vancomycin resistance and daptomycin nonsusceptibility, respectively.


Assuntos
Antibacterianos/farmacologia , Farmacorresistência Bacteriana/fisiologia , Raios Infravermelhos , Microscopia de Força Atômica/métodos , Staphylococcus aureus/efeitos dos fármacos , Daptomicina/farmacologia , Staphylococcus aureus/química , Staphylococcus aureus/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA