Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.373
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Cell ; 184(24): 5916-5931.e17, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34767757

RESUMO

There is increasing interest in the potential contribution of the gut microbiome to autism spectrum disorder (ASD). However, previous studies have been underpowered and have not been designed to address potential confounding factors in a comprehensive way. We performed a large autism stool metagenomics study (n = 247) based on participants from the Australian Autism Biobank and the Queensland Twin Adolescent Brain project. We found negligible direct associations between ASD diagnosis and the gut microbiome. Instead, our data support a model whereby ASD-related restricted interests are associated with less-diverse diet, and in turn reduced microbial taxonomic diversity and looser stool consistency. In contrast to ASD diagnosis, our dataset was well powered to detect microbiome associations with traits such as age, dietary intake, and stool consistency. Overall, microbiome differences in ASD may reflect dietary preferences that relate to diagnostic features, and we caution against claims that the microbiome has a driving role in ASD.


Assuntos
Transtorno Autístico/microbiologia , Comportamento Alimentar , Microbioma Gastrointestinal , Adolescente , Fatores Etários , Transtorno Autístico/diagnóstico , Comportamento , Criança , Pré-Escolar , Fezes/microbiologia , Feminino , Humanos , Masculino , Fenótipo , Filogenia , Especificidade da Espécie
3.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
4.
Proc Natl Acad Sci U S A ; 120(48): e2313755120, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-37983504

RESUMO

The complex, systemic pathology of sickle cell disease is driven by multiple mechanisms including red blood cells (RBCs) stiffened by polymerized fibers of deoxygenated sickle hemoglobin. A critical step toward understanding the pathologic role of polymer-containing RBCs is quantifying the biophysical changes in these cells in physiologically relevant oxygen environments. We have developed a microfluidic platform capable of simultaneously measuring single RBC deformability and oxygen saturation under controlled oxygen and shear stress. We found that RBCs with detectable amounts of polymer have decreased oxygen affinity and decreased deformability. Surprisingly, the deformability of the polymer-containing cells is oxygen-independent, while the fraction of these cells increases as oxygen decreases. We also find that some fraction of these cells is present at most physiologic oxygen tensions, suggesting a role for these cells in the systemic pathologies. Additionally, the ability to measure these pathological cells should provide clearer targets for evaluating therapies.


Assuntos
Anemia Falciforme , Saturação de Oxigênio , Humanos , Eritrócitos , Deformação Eritrocítica , Polímeros , Oxigênio
5.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Assuntos
Estenose da Valva Aórtica , Benchmarking , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Idoso , Procedimentos Clínicos , Europa (Continente)/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Segurança do Paciente
6.
Gut ; 73(5): 751-769, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38331563

RESUMO

OBJECTIVE: Chronic obstructive pulmonary disease (COPD) is a major cause of global illness and death, most commonly caused by cigarette smoke. The mechanisms of pathogenesis remain poorly understood, limiting the development of effective therapies. The gastrointestinal microbiome has been implicated in chronic lung diseases via the gut-lung axis, but its role is unclear. DESIGN: Using an in vivo mouse model of cigarette smoke (CS)-induced COPD and faecal microbial transfer (FMT), we characterised the faecal microbiota using metagenomics, proteomics and metabolomics. Findings were correlated with airway and systemic inflammation, lung and gut histopathology and lung function. Complex carbohydrates were assessed in mice using a high resistant starch diet, and in 16 patients with COPD using a randomised, double-blind, placebo-controlled pilot study of inulin supplementation. RESULTS: FMT alleviated hallmark features of COPD (inflammation, alveolar destruction, impaired lung function), gastrointestinal pathology and systemic immune changes. Protective effects were additive to smoking cessation, and transfer of CS-associated microbiota after antibiotic-induced microbiome depletion was sufficient to increase lung inflammation while suppressing colonic immunity in the absence of CS exposure. Disease features correlated with the relative abundance of Muribaculaceae, Desulfovibrionaceae and Lachnospiraceae family members. Proteomics and metabolomics identified downregulation of glucose and starch metabolism in CS-associated microbiota, and supplementation of mice or human patients with complex carbohydrates improved disease outcomes. CONCLUSION: The gut microbiome contributes to COPD pathogenesis and can be targeted therapeutically.


Assuntos
Pneumonia , Doença Pulmonar Obstrutiva Crônica , Humanos , Camundongos , Animais , Doença Pulmonar Obstrutiva Crônica/etiologia , Pulmão/metabolismo , Pulmão/patologia , Pneumonia/etiologia , Inflamação/metabolismo , Carboidratos/farmacologia
7.
Hum Brain Mapp ; 45(4): e26625, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38433665

RESUMO

Estimated age from brain MRI data has emerged as a promising biomarker of neurological health. However, the absence of large, diverse, and clinically representative training datasets, along with the complexity of managing heterogeneous MRI data, presents significant barriers to the development of accurate and generalisable models appropriate for clinical use. Here, we present a deep learning framework trained on routine clinical data (N up to 18,890, age range 18-96 years). We trained five separate models for accurate brain age prediction (all with mean absolute error ≤4.0 years, R2 ≥ .86) across five different MRI sequences (T2 -weighted, T2 -FLAIR, T1 -weighted, diffusion-weighted, and gradient-recalled echo T2 *-weighted). Our trained models offer dual functionality. First, they have the potential to be directly employed on clinical data. Second, they can be used as foundation models for further refinement to accommodate a range of other MRI sequences (and therefore a range of clinical scenarios which employ such sequences). This adaptation process, enabled by transfer learning, proved effective in our study across a range of MRI sequences and scan orientations, including those which differed considerably from the original training datasets. Crucially, our findings suggest that this approach remains viable even with limited data availability (as low as N = 25 for fine-tuning), thus broadening the application of brain age estimation to more diverse clinical contexts and patient populations. By making these models publicly available, we aim to provide the scientific community with a versatile toolkit, promoting further research in brain age prediction and related areas.


Assuntos
Encéfalo , Rememoração Mental , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Pré-Escolar , Encéfalo/diagnóstico por imagem , Difusão , Neuroimagem , Aprendizado de Máquina
8.
Am Heart J ; 267: 70-80, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37871781

RESUMO

BACKGROUND: In ST-segment elevation myocardial infarction (STEMI), complete revascularization with percutaneous coronary intervention (PCI) reduces major cardiovascular events compared with culprit-lesion-only PCI. Whether age influences these results remains unknown. METHODS: COMPLETE was a multinational, randomized trial evaluating a strategy of staged complete revascularization, consisting of angiography-guided PCI of all suitable nonculprit lesions, versus a strategy of culprit-lesion-only PCI. In this prespecified subgroup analysis, treatment effect according to age (≥65 years vs <65 years) was determined for the first coprimary outcome of cardiovascular (CV) death or new myocardial infarction (MI) and the second coprimary outcome of CV death, new MI, or ischemia-driven revascularization (IDR). Median follow-up was 35.8 months (interquartile range [IQR]: 27.6-44.3 months). RESULTS: Of 4,041 patients randomized in COMPLETE, 1,613 were aged ≥ 65 years (39.9%). Higher event rates were observed for both coprimary outcomes in patients aged ≥ 65 years comparted with those aged < 65 years (11.2% vs 7.9%, HR 1.49, 95% CI 1.22-1.83; 14.4% vs 11.8%, HR 1.28, 95% CI 1.07-1.52, respectively). Complete revascularization reduced the first coprimary outcome in patients ≥ 65 years (9.7% vs 12.5%, HR 0.77; 95% CI, 0.58-1.04) and < 65 years (6.7% vs 9.1%, HR 0.72; 95% CI, 0.54-0.96)(interaction P = .74). The second coprimary outcome was reduced in those ≥ 65 years (HR 0.56, 95% CI, 0.43-0.74) and < 65 years (HR 0.48, 95% CI, 0.37-0.61 (interaction P = .37). A sensitivity analysis was performed with consistent results demonstrated using a 75-year threshold (albeit attenuated). CONCLUSIONS: In patients with STEMI and multivessel CAD, complete revascularization compared with culprit-lesion-only PCI reduced major cardiovascular events regardless of patient age and could be considered as a revascularization strategy in older adults.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Humanos , Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/etiologia , Revascularização Miocárdica/métodos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento , Pessoa de Meia-Idade
9.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38819623

RESUMO

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/cirurgia , Valvuloplastia com Balão/efeitos adversos , Fatores de Risco , Estados Unidos , Stents
10.
Protein Expr Purif ; 217: 106442, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38336119

RESUMO

A novel tandem affinity tag is presented that enables the use of cation exchange resins for initial affinity purification, followed by an additional column step for enhanced purity and affinity tag self-removal. In this method, the highly charged heparin-binding tag binds strongly and selectively to either a strong or weak cation exchange resin based on electrostatic interactions, effectively acting as an initial affinity tag. Combining the heparin-binding tag (HB-tag) with the self-removing iCapTag™ provides a means for removing both tags in a subsequent self-cleaving step. The result is a convenient platform for the purification of diverse tagless proteins with a range of isoelectric points and molecular weights. In this work, we demonstrate a dual column process in which the tagged protein of interest is first captured from an E. coli cell lysate using a cation exchange column via a fused heparin-binding affinity tag. The partially purified protein is then diluted and loaded onto an iCapTag™ split-intein column, washed, and then incubated overnight to release the tagless target protein from the bound tag. Case studies are provided for enhanced green fluorescent protein (eGFP), beta galactosidase (ßgal), maltose binding protein (MBP) and beta lactamase (ßlac), where overall purity and host cell DNA clearance is provided. Overall, the proposed dual column process is shown to be a scalable platform technology capable of accessing both the high dynamic binding capacity of ion exchange resins and the high selectivity of affinity tags for the purification of recombinant proteins.


Assuntos
Escherichia coli , Heparina , Proteínas Recombinantes de Fusão/genética , Escherichia coli/metabolismo , Proteínas Recombinantes/química , Cromatografia de Afinidade/métodos , Heparina/metabolismo
11.
Br J Clin Pharmacol ; 90(3): 620-628, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37658550

RESUMO

This paper aims to explore the possibility of employing large language models (LLMs) - a type of artificial intelligence (AI) - in clinical pharmacology, with a focus on its possible misuse in bioweapon development. Additionally, ethical considerations, legislation and potential risk reduction measures are analysed. The existing literature is reviewed to investigate the potential misuse of AI and LLMs in bioweapon creation. The search includes articles from PubMed, Scopus and Web of Science Core Collection that were identified using a specific protocol. To explore the regulatory landscape, the OECD.ai platform was used. The review highlights the dual-use vulnerability of AI and LLMs, with a focus on bioweapon development. Subsequently, a case study is used to illustrate the potential of AI manipulation resulting in harmful substance synthesis. Existing regulations inadequately address the ethical concerns tied to AI and LLMs. Mitigation measures are proposed, including technical solutions (explainable AI), establishing ethical guidelines through collaborative efforts, and implementing policy changes to create a comprehensive regulatory framework. The integration of AI and LLMs into clinical pharmacology presents invaluable opportunities, while also introducing significant ethical and safety considerations. Addressing the dual-use nature of AI requires robust regulations, as well as adopting a strategic approach grounded in technical solutions and ethical values following the principles of transparency, accountability and safety. Additionally, AI's potential role in developing countermeasures against novel hazardous substances is underscored. By adopting a proactive approach, the potential benefits of AI and LLMs can be fully harnessed while minimizing the associated risks.


Assuntos
Farmacologia Clínica , Humanos , Inteligência Artificial , Idioma
12.
Emerg Med J ; 41(7): 440-445, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38763520

RESUMO

The Royal College of Emergency Medicine Toxicology Special Interest Group in collaboration with the UK National Poisons Information Service and the Clinical Toxicology Department at Guy's and St Thomas' NHS Foundation Trust has produced guidance to support clinicians working in the ED with the assessment and management of adults with acute opioid toxicity.Considerations regarding identification of acute opioid toxicity are discussed and recommendations regarding treatment options and secondary prevention are made. There is a focus on making recommendations on the best available evidence.


Assuntos
Analgésicos Opioides , Serviço Hospitalar de Emergência , Humanos , Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/uso terapêutico , Adulto , Reino Unido , Guias de Prática Clínica como Assunto , Overdose de Opiáceos/terapia
13.
J Environ Manage ; 356: 120561, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38479290

RESUMO

Recorded particulate matter (PM2.5) hourly trends are compared for fifteen urban recording sites distributed across central England for the period 2018 to 2022. They include 10 urban-background and five urban-traffic (roadside) sites with some located within the same urban area. The sites all show consistent background and peak distributions with mean annual values and standard deviations higher for 2018 and 2019 than for 2020 to 2022. The objective of this study is to demonstrate that trend attributes extracted from hourly recorded univariate PM2.5 trends at these sites can be used to provide reliable short-term hourly predictions and provide valuable insight into the regional variations in the recorded trends. Fifteen trend attributes extracted from the prior 12 h (t-1 to t-12) of recorded PM2.5 data were compiled and used as input to four supervised machine learning models (SML) to forecast PM2.5 concentrations up to 13 h ahead (t0 to t+12). All recording sites delivered forecasts with similar ranges of error levels for specific hours ahead which are consistent with their PM2.5 recorded ranges. Forecasting results for four representative sites are presented in detail using models trained and cross-validated with 2020 and 2021 hourly data to forecast 2021 and 2022 hourly data, respectively. A novel optimized feature selection procedure using a suite of five optimizers is used to improve the efficiency of the forecasting models. The LASSO and support vector regression models generate the best and most generalizable hourly PM2.5 forecasts from trained and validated SML models with mean average error (MAE) of between ∼1 and ∼3 µg/m3 for t0 to t+3 h ahead. A novel overfitting indicator, exploiting the cross-validation mean values, demonstrates that these two models are not affected by overfitting. Forecasts for t+6 to t+12 h forward generate higher MAE values between ∼3 and ∼4 µg/m3 due to their tendency to underestimate some of the extreme PM2.5 peaks. These findings indicate that further model refinements are required to generate more reliable short-term predictions for the t+6 to t+24 h ahead.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Poluentes Atmosféricos/análise , Cidades , Monitoramento Ambiental/métodos , Material Particulado/análise , Inglaterra , Previsões , Aprendizado de Máquina , Poluição do Ar/análise
14.
J Cell Physiol ; 238(7): 1478-1491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37269472

RESUMO

Osteohematology is an emerging research field that studies the crosstalk between hematopoietic and bone stromal cells, to elucidate the mechanisms of hematological and skeletal malignancies and diseases. The Notch is an evolutionary conserved developmental signaling pathway, with critical roles in embryonic development by controlling cell proliferation and differentiation. However, the Notch pathway is also critically involved in cancer initiation and progression, such as osteosarcoma, leukemia, and multiple myeloma. The Notch-mediated malignant cells dysregulate bone and bone marrow cells in the tumour microenvironment, resulting in disorders ranging from osteoporosis to bone marrow dysfunction. To date, the complex interplay of Notch signaling molecules in hematopoietic and bone stromal cells is still poorly understood. In this mini-review, we summarize the crosstalk between cells in bone and bone marrow and their influence under the Notch signaling pathway in physiological conditions and in tumour microenvironment.


Assuntos
Receptores Notch , Transdução de Sinais , Humanos , Medula Óssea/metabolismo , Leucemia/patologia , Mieloma Múltiplo/patologia , Receptores Notch/genética , Receptores Notch/metabolismo , Microambiente Tumoral
15.
Am Heart J ; 256: 139-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36410441

RESUMO

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos
16.
Crit Care ; 27(1): 56, 2023 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-36765419

RESUMO

Ethylene glycol (EG) is metabolized into glycolate and oxalate and may cause metabolic acidemia, neurotoxicity, acute kidney injury (AKI), and death. Historically, treatment of EG toxicity included supportive care, correction of acid-base disturbances and antidotes (ethanol or fomepizole), and extracorporeal treatments (ECTRs), such as hemodialysis. With the wider availability of fomepizole, the indications for ECTRs in EG poisoning are debated. We conducted systematic reviews of the literature following published EXTRIP methods to determine the utility of ECTRs in the management of EG toxicity. The quality of the evidence and the strength of recommendations, either strong ("we recommend") or weak/conditional ("we suggest"), were graded according to the GRADE approach. A total of 226 articles met inclusion criteria. EG was assessed as dialyzable by intermittent hemodialysis (level of evidence = B) as was glycolate (Level of evidence = C). Clinical data were available for analysis on 446 patients, in whom overall mortality was 18.7%. In the subgroup of patients with a glycolate concentration ≤ 12 mmol/L (or anion gap ≤ 28 mmol/L), mortality was 3.6%; in this subgroup, outcomes in patients receiving ECTR were not better than in those who did not receive ECTR. The EXTRIP workgroup made the following recommendations for the use of ECTR in addition to supportive care over supportive care alone in the management of EG poisoning (very low quality of evidence for all recommendations): i) Suggest ECTR if fomepizole is used and EG concentration > 50 mmol/L OR osmol gap > 50; or ii) Recommend ECTR if ethanol is used and EG concentration > 50 mmol/L OR osmol gap > 50; or iii) Recommend ECTR if glycolate concentration is > 12 mmol/L or anion gap > 27 mmol/L; or iv) Suggest ECTR if glycolate concentration 8-12 mmol/L or anion gap 23-27 mmol/L; or v) Recommend ECTR if there are severe clinical features (coma, seizures, or AKI). In most settings, the workgroup recommends using intermittent hemodialysis over other ECTRs. If intermittent hemodialysis is not available, CKRT is recommended over other types of ECTR. Cessation of ECTR is recommended once the anion gap is < 18 mmol/L or suggested if EG concentration is < 4 mmol/L. The dosage of antidotes (fomepizole or ethanol) needs to be adjusted during ECTR.


Assuntos
Antídotos , Intoxicação , Humanos , Antídotos/uso terapêutico , Fomepizol , Etanol , Diálise Renal/métodos , Glicolatos , Etilenoglicol , Intoxicação/terapia
17.
BMC Cardiovasc Disord ; 23(1): 295, 2023 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-37301870

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) can either be conducted as an elective (scheduled in advance) or a non-elective procedure performed during an unplanned hospital admission. The objective of this study was to compare the outcomes of elective and non-elective TAVI patients. METHODS: This single-centre study included 512 patients undergoing transfemoral TAVI between October 2018 and December 2020; 378 (73.8%) were admitted for elective TAVI, 134 (26.2%) underwent a non-elective procedure. Our TAVI programme entails an optimized fast-track concept aimed at minimizing the total length of stay to ≤ 5 days for elective patients which in the German healthcare system is currently defined as the minimal time period to safely perform TAVI. Clinical characteristics and survival rates at 30 days and 1 year were analysed. RESULTS: Patients who underwent non-elective TAVI had a significantly higher comorbidity burden. Median duration from admission to discharge was 6 days (elective group 6 days versus non-elective group 15 days; p < 0.001), including a median postprocedural stay of 5 days (elective 4 days versus non-elective 7 days; p < 0.001). All-cause mortality at 30 days was 1.1% for the elective group and 3.7% for non-elective patients (p = 0.030). At 1 year, all-cause mortality among elective TAVI patients was disproportionately lower than in non-elective patients (5.0% versus 18.7%, p < 0.001). In the elective group, 54.5% of patients could not be discharged early due to comorbidities or procedural complications. Factors associated with a failure of achieving a total length of stay of ≤ 5 days comprised frailty syndrome, renal impairment as well as new permanent pacemaker implantation, new bundle branch block or atrial fibrillation, life-threatening bleeding, and the use of self-expanding valves. After multivariate adjustment, new permanent pacemaker implantation (odds ratio 6.44; 95% CI 2.59-16.00), life-threatening bleeding (odds ratio 4.19; 95% confidence interval 1.82-9.66) and frailty syndrome (odds ratio 5.15; 95% confidence interval 2.40-11.09; all p < 0.001, respectively) were confirmed as significant factors. CONCLUSIONS: While non-elective patients had acceptable periprocedural outcomes, mortality rates at 1 year were significantly higher compared to elective patients. Approximately only half of elective patients could be discharged early. Improvements in periprocedural care, follow-up strategies and optimized treatment of both elective and non-elective TAVI patients are needed.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Fragilidade , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Idoso Fragilizado , Universidades , Bloqueio de Ramo/etiologia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco , Próteses Valvulares Cardíacas/efeitos adversos
18.
Curr Cardiol Rep ; 25(11): 1425-1431, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37815660

RESUMO

PURPOSE OF REVIEW: As TAVR is increasingly performed on younger patients with a longer life expectancy, the number of redo-TAVR procedures is likely to increase in the coming years. Limited data is currently available on this sometimes challenging procedure. We provide a summary of currently published literature on management of patients with a failed transcatheter aortic valve. RECENT FINDINGS: Recent registry data have increased the clinical knowledge on redo-TAVR. Additionally, numerous bench studies have provided valuable insights into the technical aspects of redo-TAVR with various combinations of valve types. Redo-TAVR can be performed safely in selected cases with a high procedural success and good short-term outcomes. However, at present, the procedure remains relatively infrequent and many patients are not eligible. Bench testing can be useful to understand important concepts such as valve expansion, neoskirt, leaflet overhang, and leaflet deflection as well as their potential clinical implications.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco , Desenho de Prótese
19.
Curr Cardiol Rep ; 25(10): 1361-1371, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37698820

RESUMO

PURPOSE OF REVIEW: Mitral and tricuspid regurgitation represents a clinical challenge. They are associated with a poor prognosis, and many patients are not eligible for conventional surgery. Transcatheter therapies have been the focus of numerous studies and devices over the past decade. Here, we provide a summary of current options for transcatheter treatment of these 2 entities. RECENT FINDINGS: Recent studies have demonstrated the benefits of edge-to-edge repair for increasing numbers of patients. Encouraging early results with transcatheter valve replacement are also becoming available. To date, transcatheter edge-to-edge repair is currently the first-line transcatheter treatment for both mitral and tricuspid regurgitation for many patients who are not candidates for surgery. A number of transcatheter replacement devices are under development and clinical investigation but, for the most part, their current use is limited to compassionate cases or clinical trials.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia
20.
Br J Sports Med ; 57(5): 278-291, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36650032

RESUMO

Hamstring injuries (HSIs) are the most common athletic injury in running and pivoting sports, but despite large amounts of research, injury rates have not declined in the last 2 decades. HSI often recur and many areas are lacking evidence and guidance for optimal rehabilitation. This study aimed to develop an international expert consensus for the management of HSI. A modified Delphi methodology and consensus process was used with an international expert panel, involving two rounds of online questionnaires and an intermediate round involving a consensus meeting. The initial information gathering round questionnaire was sent to 46 international experts, which comprised open-ended questions covering decision-making domains in HSI. Thematic analysis of responses outlined key domains, which were evaluated by a smaller international subgroup (n=15), comprising clinical academic sports medicine physicians, physiotherapists and orthopaedic surgeons in a consensus meeting. After group discussion around each domain, a series of consensus statements were prepared, debated and refined. A round 2 questionnaire was sent to 112 international hamstring experts to vote on these statements and determine level of agreement. Consensus threshold was set a priori at 70%. Expert response rates were 35/46 (76%) (first round), 15/35 (attendees/invitees to meeting day) and 99/112 (88.2%) for final survey round. Statements on rehabilitation reaching consensus centred around: exercise selection and dosage (78.8%-96.3% agreement), impact of the kinetic chain (95%), criteria to progress exercise (73%-92.7%), running and sprinting (83%-100%) in rehabilitation and criteria for return to sport (RTS) (78.3%-98.3%). Benchmarks for flexibility (40%) and strength (66.1%) and adjuncts to rehabilitation (68.9%) did not reach agreement. This consensus panel recommends individualised rehabilitation based on the athlete, sporting demands, involved muscle(s) and injury type and severity (89.8%). Early-stage rehab should avoid high strain loads and rates. Loading is important but with less consensus on optimum progression and dosage. This panel recommends rehabilitation progress based on capacity and symptoms, with pain thresholds dependent on activity, except pain-free criteria supported for sprinting (85.5%). Experts focus on the demands and capacity required for match play when deciding the rehabilitation end goal and timing of RTS (89.8%). The expert panellists in this study followed evidence on aspects of rehabilitation after HSI, suggesting rehabilitation prescription should be individualised, but clarified areas where evidence was lacking. Additional research is required to determine the optimal load dose, timing and criteria for HSI rehabilitation and the monitoring and testing metrics to determine safe rapid progression in rehabilitation and safe RTS. Further research would benefit optimising: prescription of running and sprinting, the application of adjuncts in rehabilitation and treatment of kinetic chain HSI factors.


Assuntos
Traumatismos em Atletas , Músculos Isquiossurais , Corrida , Humanos , Volta ao Esporte , Londres , Técnica Delphi , Traumatismos em Atletas/cirurgia , Músculos Isquiossurais/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA