Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Magn Reson Med ; 86(6): 3224-3235, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34337778

RESUMO

PURPOSE: Lung impairment from functional MRI is frequently assessed as defect percentage. The defect distribution, however, is currently not quantified. The purpose of this work was to develop a novel measure that quantifies how clustered or scattered defects in functional lung MRI appear, and to evaluate it in pediatric cystic fibrosis. THEORY: The defect distribution index (DDI) calculates a score for each lung voxel categorized as defected. The index increases according to how densely and how far an expanding circle around a defect voxel contains more than 50% defect voxels. METHODS: Fractional ventilation and perfusion maps of 53 children with cystic fibrosis were previously acquired with matrix pencil decomposition MRI. In this work, the DDI is compared to a visual score of 3 raters who evaluated how clustered the lung defects appear. Further, spearman correlations between DDI and lung function parameters were determined. RESULTS: The DDI strongly correlates with the visual scoring (r = 0.90 for ventilation; r = 0.88 for perfusion; P < .0001). Although correlations between DDI and defect percentage are moderate to strong (r = 0.61 for ventilation; r = 0.75 for perfusion; P < .0001), the DDI distinguishes between patients with comparable defect percentage. CONCLUSION: The DDI is a novel measure for functional lung MRI. It provides complementary information to the defect percentage because the DDI assesses defect distribution rather than defect size. The DDI is applicable to matrix pencil MRI data of cystic fibrosis patients and shows very good agreement with human perception of defect distributions.


Assuntos
Fibrose Cística , Criança , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão , Respiração
2.
J Appl Physiol (1985) ; 136(3): 460-471, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38269412

RESUMO

Multiple-breath washout (MBW) is an established technique to assess functional residual capacity (FRC) and ventilation inhomogeneity in the lung. Indirect calculation of nitrogen concentration requires accurate measurement of gas concentrations. To investigate the accuracy of the CO2 concentration and molar mass (MM) values used for the indirect calculation of nitrogen concentration in a commercial MBW device [EasyOne Pro LAB (EOPL), ndd Medizintechnik AG, Switzerland] and its impact on outcomes. We used high-precision gas mixtures to evaluate CO2 and MM sensor output in vivo and in vitro. We developed updated algorithms to correct observed errors and assessed the impact on MBW outcomes and FRC measurement accuracy compared with body plethysmography. The respiratory exchange ratio (RER)-based adjustment of the measured CO2 signal used in the EOPL led to an overestimated CO2 signal (range -0.1% to 1.0%). In addition, an uncorrected dependence on humidity was identified. These combined effects resulted in an overestimation of expired nitrogen concentrations (range -0.7% to 2.6%), and consequently MBW outcomes. Corrected algorithms reduced the mean (SD) cumulative expired volume by 15.8% (9.7%), FRC by 6.6% (3.0%), and lung clearance index by 9.9% (7.6%). Differences in FRC between the EOPL and body plethysmography further increased. Inadequate signal correction causes RER- and humidity-dependent expired nitrogen concentration errors and overestimation of test outcomes. Updated algorithms reduce average signal error, however, RER values far from the population average still cause measurement errors. Despite improved signal accuracy, the updated algorithm increased the difference in FRC between the EOPL and body plethysmography.NEW & NOTEWORTHY We investigated the accuracy of the molar mass (MM) and CO2 sensors of a commercial multiple-breath washout device (ndd Medizintechnik AG, Switzerland). We identified humidity and respiratory exchange ratio-dependent errors that in most measurements resulted in an overestimation of expired nitrogen concentrations, and consequently, MBW results. Functional residual capacity and lung clearance index decreased by 6.6% and 9.9%, respectively. Despite improved signal accuracy, the difference in FRC between the EOPL and body plethysmography increased.


Assuntos
Testes Respiratórios , Dióxido de Carbono , Adulto , Criança , Humanos , Testes Respiratórios/métodos , Reprodutibilidade dos Testes , Pulmão , Nitrogênio
3.
Front Pediatr ; 12: 1393291, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38910962

RESUMO

Background: Multiple-breath washout (MBW) is a sensitive method for assessing lung volumes and ventilation inhomogeneity in infants, but remains prone to artefacts (e.g., sighs). There is a lack of tools for systematic retrospective analysis of existing datasets, and unlike N2-MBW in older children, there are few specific quality control (QC) criteria for artefacts in infant SF6-MBW. Aim: We aimed to develop a computer-based tool for systematic evaluation of visual QC criteria of SF6-MBW measurements and to investigate interrater agreement and effects on MBW outcomes among three independent examiners. Methods: We developed a software package for visualization of raw Spiroware (Eco Medics AG, Switzerland) and signal processed WBreath (ndd Medizintechnik AG, Switzerland) SF6-MBW signal traces. Interrater agreement among three independent examiners (two experienced, one novice) who systematically reviewed 400 MBW trials for visual artefacts and the decision to accept/reject the washin and washout were assessed. Results: Our tool visualizes MBW signals and provides the user with (i) display options (e.g., zoom), (ii) options for a systematic QC assessment [e.g., decision to accept or reject, identification of artefacts (leak, sigh, irregular breathing pattern, breath hold), and comments], and (iii) additional information (e.g., automatic identification of sighs). Reviewer agreement was good using pre-defined QC criteria (κ 0.637-0.725). Differences in the decision to accept/reject had no substantial effect on MBW outcomes. Conclusion: Our visual quality control tool supports a systematic retrospective analysis of existing data sets. Based on predefined QC criteria, even inexperienced users can achieve comparable MBW results.

4.
Respir Med Res ; 83: 100993, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37058881

RESUMO

Lung function testing and lung imaging are commonly used techniques to monitor respiratory diseases, such as cystic fibrosis (CF). The nitrogen (N2) multiple-breath washout technique (MBW) has been shown to detect ventilation inhomogeneity in CF, but the underlying pathophysiological processes that are altered are often unclear. Dynamic oxygen-enhanced magnetic resonance imaging (OE-MRI) could potentially be performed simultaneously with MBW because both techniques require breathing of 100% oxygen (O2) and may allow for visualisation of alterations underlying impaired MBW outcomes. However, simultaneous MBW and OE-MRI has never been assessed, potentially as it requires a magnetic resonance (MR) compatible MBW equipment. In this pilot study, we assessed whether MBW and OE-MRI can be performed simultaneously using a commercial MBW device that has been modified to be MR-compatible. We performed simultaneous measurements in five healthy volunteers aged 25-35 years. We obtained O2 and N2 concentrations from both techniques, and generated O2 wash-in time constant and N2 washout maps from OE-MRI data. We obtained good quality simultaneous measurements in two healthy volunteers due to technical challenges related to the MBW equipment and poor tolerance. Oxygen and N2 concentrations from both techniques, as well as O2 wash-in time constant maps and N2 washout maps could be obtained, suggesting that simultaneous measurements may have the potential to allow for comparison and visualization of regional differences in ventilation underlying impaired MBW outcomes. Simultaneous MBW and OE-MRI measurements can be performed with a modified MBW device and may help to understand MBW outcomes, but the measurements are challenging and have poor feasibility.


Assuntos
Fibrose Cística , Oxigênio , Humanos , Adulto , Projetos Piloto , Testes Respiratórios/métodos , Pulmão/diagnóstico por imagem , Fibrose Cística/diagnóstico por imagem , Imageamento por Ressonância Magnética
5.
Pediatr Pulmonol ; 57(5): 1180-1187, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35182057

RESUMO

BACKGROUND: The recently described sensor-crosstalk error in the multiple-breath washout (MBW) device Exhalyzer D (Eco Medics AG) could highly influence clinimetric properties and the current interpretation of MBW results. This study reanalyzes MBW data from clinical routine in the corrected software version Spiroware® 3.3.1 and evaluates the effect on outcomes. METHODS: We included nitrogen-MBW data from healthy children and children with cystic fibrosis (CF) from previously published trials and ongoing cohort studies. We specifically compared lung clearance index (LCI) analyzed in Spiroware 3.2.1 and 3.3.1 with regard to (i) feasibility, (ii) repeatability, and (iii) validity as outcome parameters in children with CF. RESULTS: (i) All previously collected measurements could be reanalyzed and resulted in unchanged feasibility in Spiroware 3.3.1. (ii) Short- and midterm repeatability of LCI was similar in both software versions. (iii) Clinical validity of LCI remained similar in Spiroware 3.3.1; however, this resulted in lower values. Discrimination between health and disease was comparable between both software versions. The increase in LCI over time was less pronounced with 0.16 LCI units/year (95% confidence interval [CI] 0.08; 0.24) versus 0.30 LCI units/year (95% CI 0.21; 0.38) in 3.2.1. Response to intervention in children receiving CF transmembrane conductance-modulator therapy resulted in a comparable improvement in LCI, in both Spiroware versions. CONCLUSION: Our study confirms that clinimetric properties of LCI remain unaffected after correction for the cross-sensitivity error in Spiroware software.


Assuntos
Testes Respiratórios , Fibrose Cística , Testes Respiratórios/métodos , Criança , Humanos , Pulmão , Nitrogênio , Testes de Função Respiratória/métodos
6.
PLoS One ; 17(10): e0275866, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36240198

RESUMO

BACKGROUND: Accurate breath detection is essential for the computation of outcomes in the multiple-breath washout (MBW) technique. This is particularly important in young children, where irregular breathing is common, and the designation of inspirations and expirations can be challenging. AIM: To investigate differences between a commercial and a novel breath-detection algorithm and to characterize effects on MBW outcomes in children. METHODS: We replicated the signal processing and algorithms used in Spiroware software (v3.3.1, Eco Medics AG). We developed a novel breath detection algorithm (custom) and compared it to Spiroware using 2,455 nitrogen (N2) and 325 sulfur hexafluoride (SF6) trials collected in infants, children, and adolescents. RESULTS: In 83% of N2 and 32% of SF6 trials, the Spiroware breath detection algorithm rejected breaths and did not use them for the calculation of MBW outcomes. Our custom breath detection algorithm determines inspirations and expirations based on flow reversal and corresponding CO2 elevations, and uses all breaths for data analysis. In trials with regular tidal breathing, there were no differences in outcomes between algorithms. However, in 10% of pre-school children tests the number of breaths detected differed by more than 10% and the commercial algorithm underestimated the lung clearance index by up to 21%. CONCLUSION: Accurate breath detection is challenging in young children. As the MBW technique relies on the cumulative analysis of all washout breaths, the rejection of breaths should be limited. We provide an improved algorithm that accurately detects breaths based on both flow reversal and CO2 concentration.


Assuntos
Testes Respiratórios , Hexafluoreto de Enxofre , Adolescente , Algoritmos , Testes Respiratórios/métodos , Dióxido de Carbono , Criança , Pré-Escolar , Humanos , Lactente , Pulmão , Nitrogênio
7.
ERJ Open Res ; 8(1)2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35295235

RESUMO

Background: Volumetric capnography (VCap) is a simpler alternative to multiple-breath washout (MBW) to detect ventilation inhomogeneity in patients with cystic fibrosis (CF). However, its diagnostic performance is influenced by breathing dynamics. We introduce two novel VCap indices, the capnographic inhomogeneity indices (CIIs), that may overcome this limitation and explore their diagnostic characteristics in a cohort of CF patients. Methods: We analysed 320 N2-MBW trials from 50 CF patients and 65 controls (age 4-18 years) and calculated classical VCap indices, such as slope III (SIII) and the capnographic index (KPIv). We introduced novel CIIs based on a theoretical lung model and assessed their diagnostic performance compared to classical VCap indices and the lung clearance index (LCI). Results: Both CIIs were significantly higher in CF patients compared with controls (mean±sd CII1 5.9±1.4% versus 5.1±1.0%, p=0.002; CII2 7.7±1.8% versus 6.8±1.4%, p=0.002) and presented strong correlation with LCI (CII1 r2=0.47 and CII2 r2=0.44 in CF patients). Classical VCap indices showed inferior discriminative ability (SIII 2.3±1.0%/L versus 1.9±0.7%/L, p=0.013; KPIv 3.9±1.3% versus 3.5±1.2%, p=0.071), while the correlation with LCI was weak (SIII r2=0.03; KPIv r2=0.08 in CF patients). CIIs showed lower intra-subject inter-trial variability, calculated as coefficient of variation for three and relative difference for two trials, than classical VCap indices, but higher than LCI (CII1 11.1±8.2% and CII2 11.0±8.0% versus SIII 16.3±13.5%; KPIv 15.9±12.8%; LCI 5.9%±4.2%). Conclusion: CIIs detect ventilation inhomogeneity better than classical VCap indices and correlate well with LCI. However, further studies on their diagnostic performance and clinical utility are required.

8.
Pediatr Pulmonol ; 56(8): 2642-2653, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33991038

RESUMO

BACKGROUND: Multiple-breath inert gas washout (MBW) is a sensitive technique to assess lung volumes and ventilation inhomogeneity in infancy. Poor agreement amongst commercially available setups and a lack of transparency in the underlying algorithms for the computation of infant MBW outcomes currently limit the widespread application of MBW as a surveillance tool in early lung disease. METHODS: We determined all computational steps in signal processing and the calculation of MBW outcomes in the current infant WBreath/Exhalyzer D setup (Exhalyzer D device, Eco Medics AG; WBreath software version 3.28.0, ndd Medizintechnik AG; Switzerland). We developed a revised WBreath version based on current consensus guidelines and compared outcomes between the current (3.28.0) and revised (3.52.3) WBreath version. We analyzed 60 visits from 40 infants with cystic fibrosis (CF) and 20 healthy controls at 6 weeks and 1 year of age. RESULTS: Investigation into the algorithms in WBreath 3.28.0 revealed discrepancies from current consensus guidelines, which resulted in a potential overestimation of functional residual capacity (FRC) and underestimation of lung clearance index (LCI). We developed a revised WBreath version (3.52.3), which overall resulted in 6.7% lower FRC (mean (SD) -1.78 (0.99) mL/kg) and 14.1% higher LCI (1.11 (0.57) TO) than WBreath version 3.28.0. CONCLUSION: Comprehensive investigation into the signal processing and algorithms used for analysis of MBW measurements improves the transparency and robustness of infant MBW data. The revised software version calculates outcomes according to consensus guidelines. Future work is needed to validate and compare outcomes between infant MBW setups.


Assuntos
Testes Respiratórios , Fibrose Cística , Fibrose Cística/diagnóstico , Capacidade Residual Funcional , Humanos , Lactente , Pulmão , Testes de Função Respiratória
9.
J Appl Physiol (1985) ; 131(3): 1148-1156, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34351818

RESUMO

Nitrogen multiple-breath washout is an established technique to assess functional residual capacity and ventilation inhomogeneity in the lung. Accurate measurement of gas concentrations is essential for the appropriate calculation of clinical outcomes. We investigated the accuracy of oxygen and carbon dioxide gas sensor measurements used for the indirect calculation of nitrogen concentration in a commercial multiple-breath washout device (Exhalyzer D, Eco Medics AG, Duernten, Switzerland) and its impact on functional residual capacity and lung clearance index. High-precision calibration gas mixtures and mass spectrometry were used to evaluate sensor output. We assessed the impact of corrected signal processing on multiple-breath washout outcomes in a data set of healthy children and children with cystic fibrosis using custom analysis software. We found inadequate correction for the cross sensitivity of the oxygen and carbon dioxide sensors in the Exhalyzer D device. This results in an overestimation of expired nitrogen concentration and consequently, multiple-breath washout outcomes. Breath-by-breath correction of this error reduced the mean (SD) cumulative expired volume by 19.6% (5.0%), functional residual capacity by 8.9% (2.2%), and lung clearance index by 11.9% (4.0%). It also substantially reduced the level of the tissue nitrogen signal at the end of measurements. Inadequate correction for cross sensitivity in the oxygen and carbon dioxide gas sensors of the Exhalyzer D device leads to an overestimation of functional residual capacity and lung clearance index. Correction of this error is possible and could be applied by reanalyzing the measurements in an updated software version.NEW & NOTEWORTHY We investigated the sensor accuracy of a prominent nitrogen multiple-breath washout (N2MBW) device (Eco Medics AG, Duernten, Switzerland) as a possible cause of lack of comparability between outcomes of different MBW devices and methods. We identified an error in the nitrogen concentration calculation of this device, which results in a 10%-15% overestimation of primary outcomes, functional residual capacity, and lung clearance index. It also leads to a significant overestimation of nitrogen back-diffusion into the lungs.


Assuntos
Fibrose Cística , Testes Respiratórios , Criança , Capacidade Residual Funcional , Humanos , Pulmão , Respiração , Testes de Função Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA