Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466042

RESUMO

AIMS: Premature ventricular contractions (PVC) and non-sustained ventricular tachycardia (NSVT) are commonly observed in light chain cardiac amyloidosis (AL-CA), but their association with prognosis is still unclear. We aimed to evaluate the prognostic value of PVCs and NSVT in patients with moderate-to-advanced AL-CA. METHODS AND RESULTS: We retrospectively included patients with AL-CA at modified 2004 Mayo stages II-IIIb between February 2014 and December 2020. Twenty-four-hour Holter recordings were assessed on admission. The outcomes included (i) new onset of adverse ventricular arrhythmia (VA) or sudden cardiac death (SCD) and (ii) cardiac death during follow-up. Of the 143 patients studied (60.41 ± 11.06 years, male 64.34%), 132 (92.31%) had presence of PVC, and 50 (34.97%) had NSVT on Holter. Twelve (8.4%) patients died in hospital and 131 patients were followed up (median 24.4 months), among whom 71 patients had cardiac death, and 15 underwent adverse VA/SCD. NSVT [hazard ratio (HR): 13.57, 95% confidence interval (CI): 3.06-60.18, P < 0.001], log-transformed PVC counts (HR: 1.46, 95%CI: 1.15-1.86, P = 0.002) and PVC burden (HR: 1.43 95%CI:1.14-1.80, P = 0.002) were predictive of new onset of adverse VA/SCD. The highest tertile of PVC counts (HR: 2.33, 95%CI: 1.27-4.28, P = 0.006) and PVC burden (HR: 2.58, 95%CI: 1.42-4.69, P = 0.002), rather than NSVT (HR: 1.16, 95%CI: 0.67-1.98, P = 0.603), was associated with cardiac death. Higher PVC counts/burden provided incremental value on modified 2004 Mayo stage in predicting cardiac death, with C index increasing from 0.681 to 0.712 and 0.717, respectively (P values <0.05). CONCLUSION: PVC count, burden, and NSVT significantly correlated with adverse VA/SCD during follow-up in patients with AL-CA. Higher PVC counts/burdens added incremental value for predicting cardiac death.


Assuntos
Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Eletrocardiografia Ambulatorial , Morte Súbita Cardíaca
2.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37971899

RESUMO

AIMS: Traditional ablation strategies including targeting the earliest Purkinje potential (PP) during left posterior fascicular (LPF) ventricular tachycardia (VT) or linear ablation at the middle segment of LPF during sinus rhythm are commonly used for the treatment of LPF-VT. Catheter ablation for LPF-VT targeting fragmented antegrade Purkinje (FAP) potential during sinus rhythm is a novel approach. We aimed to compare safety and efficacy of different ablation strategies (FAP ablation vs. traditional ablation) for the treatment of LPF-VT. METHODS AND RESULTS: Consecutive patients with electrocardiographically documented LPF-VT referred for catheter ablation received either FAP ablation approach or traditional ablation approach. Electrophysiological characteristics, procedural complications, and long-term clinical outcome were assessed. A total of 189 consecutive patients who underwent catheter ablation for LPF-VT were included. Fragmented antegrade Purkinje ablation was attempted in 95 patients, and traditional ablation was attempted in 94 patients. Acute ablation success with elimination of LPF-VT was achieved in all patients. Left posterior fascicular block occurred in 11 of 95 (11.6%) patients in the FAP group compared with 75 of 94 (79.8%) patients in the traditional group (P < 0.001). Fragmented antegrade Purkinje ablation was associated with significant shorter procedure time (94 ± 26 vs. 117 ± 23 min, P = 0.03) and fewer radiofrequency energy applications (4.1 ± 2.4 vs. 6.3 ± 3.5, P = 0.003) compared with the traditional group. One complete atrioventricular block and one left bundle branch block were seen in the traditional group. Over mean follow-up of 65 months, 89 (93.7%) patients in the FAP group and 81 (86.2%) patients in the traditional group remained free of recurrent VT off antiarrhythmic drugs (P = 0.157). CONCLUSION: Left posterior fascicular-ventricular tachycardia ablation utilizing FAP and traditional ablation approaches resulted in similar acute and long-term procedural outcomes. Serious His-Purkinje injury did occur infrequently during traditional ablation. The use of FAP ablation approach was associated with shorter procedure time and fewer radiofrequency energy applications, especially for non-inducible patients.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Eletrocardiografia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Bloqueio de Ramo , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
J Cardiovasc Electrophysiol ; 31(6): 1307-1314, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32250512

RESUMO

BACKGROUND: The safety and efficacy of superior vena cava (SVC) isolation using second-generation cryoballoon (CB) ablation remain unknown. METHODS: A total of 26 (3.2%) patients with SVC-related paroxysmal atrial fibrillation (AF) from a consecutive series of 806 patients who underwent second-generation CB were included. Pulmonary vein isolation was initially achieved by CB ablation. If the SVC trigger was determined, the electrical isolation of SVC isolation was performed using the second-generation CB. RESULTS: Real-time SVC potential was observed in all patients. Isolation of the SVC was successfully accomplished in 21 (80.8%) patients. The mean number of freeze cycles in each patient was 2.1 ± 1.1. The mean time to isolation and ablation duration were 22.5 ± 14.2 seconds and 94.5 ± 22.3 seconds, respectively. A transient phrenic nerve (PN) injury was observed in five patients (19.2%). There were two patients (7.7%) experienced reversible sinus node injury during the first application. During a mean follow-up period of 13.2 ± 5.8 months, four patients (15.4%) had atrial arrhythmia recurrences. CONCLUSION: Isolation of SVC using the second-generation 28-mm CB is feasible when SVC driver during AF is identified. Vigilant monitoring of PN function during CB ablation of SVC is needed to avoid PN injury.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Criocirurgia/instrumentação , Veia Cava Superior/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Traumatismos Cardíacos/etiologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/etiologia , Nervo Frênico/lesões , Recidiva , Estudos Retrospectivos , Nó Sinoatrial/lesões , Fatores de Tempo , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiopatologia
4.
J Cardiovasc Electrophysiol ; 30(4): 557-564, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30661266

RESUMO

BACKGROUND: Dextrocardia with situs inversus is a rare cardiac positional anomaly. Catheter ablation procedures performed in this set of patients have not been sufficiently reported. METHODS: A total of 10 patients with dextrocardia and situs inversus who received catheter ablation for supraventricular tachycardia (SVT) were included from a cohort of over 20 000 cases of catheter ablation for SVT in three centers from 2005 to 2016. All patients underwent electrophysiologic study and catheter ablation of SVT. Ablation targets were selected based on different tachycardia mechanisms with the primary endpoint of noninduction of tachycardia. RESULTS: The average age was 32.4 ± 5.6 years. Congenitally corrected transposition of great arteries (TGA) with situs inversus and D-looping of the ventricles and aorta (congenitally corrected TGA {I,D,D}) was found in four patients, while the other six patients exhibited mirror-image dextrocardia {I,L,L}. The mechanisms of SVT were atrioventricular nodal reentrant tachycardia in four patients, atrioventricular reentrant tachycardia in three, typical atrial flutter in one, intra-atrial reentrant tachycardia in one, and focal atrial tachycardia in one. Immediate procedural success was achieved in 9 out of 10 patients with no procedural complications. During a follow-up period of 6.3 ± 3.5 years on average, all patients remained free from recurrent tachycardia. CONCLUSIONS: For patients with dextrocardia and situs inversus, catheter ablation of SVT is safe and feasible. Differences in catheter maneuver and fluroscopy projection, along with difficulties in distorted anatomy are major obstacles for successful ablation.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Dextrocardia/complicações , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Flutter Atrial/complicações , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Pequim , Ablação por Cateter/efeitos adversos , Criança , Dextrocardia/diagnóstico por imagem , Dextrocardia/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/complicações , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento , Adulto Jovem
5.
J Cardiovasc Electrophysiol ; 30(1): 32-38, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30288848

RESUMO

INTRODUCTION: The procedural findings and clinical outcome of second-generation cryoballoon (CB2) ablation in patients with variant pulmonary vein (PV) anatomy have not been fully investigated. METHODS: A total of 424 consecutive patients who underwent PV isolation with CB2 were included. Computed tomographic (CT) scan was performed in all patients before the procedure. The study population was divided into common PV, accessory PV, and nonvariant PV groups according to the CT scan. Procedural findings and clinical outcome between the three groups were compared. RESULTS: Variant PV anatomy was observed in 118 of 424 (27.8%) patients. PV isolation was successfully achieved in all patients in three groups with low rates of need for touch-up ablation (P = 0.974). Total procedure time was longer in the accessory PV group compared with nonvariant PV group (53.7 ± 12.9 vs 49.5 ± 8.8 minutes; P < 0.001). More number of applications per patient were required in accessory PV group compared with the nonvariant PV and common PV groups (7.5 ± 2.1 vs 6.5 ± 1.6, P < 0.001; 7.5 ± 2.1 vs 6.8 ± 1.4, P = 0.027, respectively). No significant difference in phrenic nerve (PN) injury was observed between the three groups (P = 0.693). During mean follow-up duration of 16.1 ± 3.3 months, there was no significant difference in rates of atrial fibrillation (AF) recurrences in the three groups (13 of 43 common PV group, 21 of 75 accessory PV group, and 80 of 306 nonvariant PV group, P = 0.178). CONCLUSION: Variant PV patterns are common in patients undergoing ablation for drug-resistant AF. CB2 ablation appears to be a reasonable strategy in the setting of the variant PV anatomy with a small increase in procedure time and the number of cryoapplications.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/anormalidades , Veias Pulmonares/cirurgia , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Angiografia por Tomografia Computadorizada , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 30(4): 541-549, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30661263

RESUMO

BACKGROUND: While the left sinus of Valsalva (LSV) is a frequent origin of ventricular arrhythmias (VAs). Uncommonly, VAs with right bundle branch block (RBBB) morphology may be successfully terminated from the LSV. OBJECTIVE: We aimed to investigate the electrocardiographic and electrophysiologic characteristics of VAs with RBBB which were successfully eliminated from the LSV. METHODS: We identified patients with VAs successfully ablated from the LSV from January 2014 to December 2017 and compared electrophysiologic characteristics and ablation sites of those VAs with RBBB versus a control group of patients with left bundle branch block morphology. RESULTS: We identified 18 patients with RBBB and predominant "R" waves in the precordial leads. In 12 (66.7%) patients, a small "s" wave in lead V2 and positive "R" in the remaining pericardial leads could be seen. Overall, a single "V" potential was seen in 72.2% of patients in the study group, while discrete potentials were recorded in 80% of the patients in the control group. The majority (88.9%) of the VAs could only be terminated at the nadir of the LSV in the study group. After mean follow-up of 33 ± 14 months, 93.8% and 92% were free of VAs after initial ablation in study and control group, respectively (P = 0.99). CONCLUSION: Some VAs with predominant monophasic "R" wave in precordial leads could be terminated from LSV, especially a small "s" wave in lead V2 was recorded. The nadir of LSV is highly successful for RBBB VAs and single electrogram was recorded at the target for most of the cases.


Assuntos
Bloqueio de Ramo/cirurgia , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Seio Aórtico/cirurgia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Potenciais de Ação , Adulto , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Seio Aórtico/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Adulto Jovem
7.
J Cardiovasc Electrophysiol ; 30(9): 1560-1568, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31111602

RESUMO

BACKGROUND: Ventricular tachycardia (VT) is frequently encountered in patients with repaired and unrepaired congenital heart disease (CHD), causing significant morbidity and sudden cardiac death. Data regarding underlying VT mechanisms and optimal ablation strategies in these patients remain limited. OBJECTIVE: To describe the electrophysiologic mechanisms, ablation strategies, and long-term outcomes in patients with CHD undergoing VT ablation. METHODS: Forty-eight patients (mean age 41.3 ± 13.3 years, 77.1% male) with CHD underwent a total of 57 VT ablation procedures at two centers from 2000 to 2017. Electrophysiologic and follow-up data were analyzed. RESULTS: Of the 77 different VTs induced at initial or repeat ablation, the underlying mechanism in 62 (81.0%) was due to scar-related re-entry; the remaining included four His-Purkinje system-related macrore-entry VTs and focal VTs mainly originating from the outflow tract region (8 of 11, 72.7%). VT-free survival after a single procedure was 72.9% (35 of 48) at a median follow-up of 53 months. VT-free survival after multiple procedures was 85.4% (41 of 48) at a median follow-up of 52 months. There were no major complications. Three patients died during the follow-up period from nonarrhythmic causes, including heart failure and cardiac surgery complication. CONCLUSION: While scar-related re-entry is the most common VT mechanism in patients with CHD, importantly, nonscar-related VT may also be present. In experienced tertiary care centers, ablation of both scar-related and nonscar-related VT in patients with CHD is safe, feasible, and effective over long-term follow-up.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas/complicações , Frequência Cardíaca , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Colorado , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Philadelphia , Intervalo Livre de Progressão , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
8.
J Cardiovasc Electrophysiol ; 30(3): 366-373, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30575168

RESUMO

BACKGROUND: Ripple mapping displays every deflection of a bipolar electrogram and enables the visualization of conduction channels (RMCC) within postinfarction ventricular scar to guide ventricular tachycardia (VT) ablation. The utility of RMCC identification for facilitation of VT ablation in the setting of arrhythmogenic right ventricular cardiomyopathy (ARVC) has not been described. OBJECTIVE: We sought to (a) identify the slow conduction channels in the endocardial/epicardial scar by ripple mapping and (b) retrospectively analyze whether the elimination of RMCC is associated with improved VT-free survival, in ARVC patients. METHODS: High-density right ventricular endocardial and epicardial electrograms were collected using the CARTO 3 system in sinus rhythm or ventricular pacing and reviewed for RMCC. Low-voltage zones and abnormal myocardium in the epicardium were identified by using standardized late-gadolinium-enhanced (LGE) magnetic resonance imaging (MRI) signal intensity (SI) z-scores. RESULTS: A cohort of 20 ARVC patients that had undergone simultaneous high-density right ventricular endocardial and epicardial electrogram mapping was identified (age 44 ± 13 years). Epicardial scar, defined as bipolar voltage less than 1.0 mV, occupied 47.6% (interquartile range [IQR], 30.9-63.7) of the total epicardial surface area and was larger than endocardial scar, defined as bipolar voltage less than 1.5 mV, which occupied 11.2% (IQR, 4.2 ± 17.8) of the endocardium (P < 0.01). A median 1.5 RMCC, defined as continuous corridors of sequential late activation within scar, were identified per patient (IQR, 1-3), most of which were epicardial. The median ratio of RMCC ablated was 1 (IQR, 0.6-1). During a median follow-up of 44 months (IQR, 11-49), the ratio of RMCC ablated was associated with freedom from recurrent VT (hazard ratio, 0.01; P = 0.049). Among nine patients with adequate MRI, 73% of RMCC were localized in LGE regions, 24% were adjacent to an area with LGE, and 3% were in regions without LGE. CONCLUSION: Slow conduction channels within endocardial or epicardial ARVC scar were delineated clearly by ripple mapping and corresponded to critical isthmus sites during entrainment. Complete elimination of RMCC was associated with freedom from VT.


Assuntos
Potenciais de Ação , Displasia Arritmogênica Ventricular Direita/complicações , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/cirurgia , Frequência Cardíaca , Pericárdio/cirurgia , Taquicardia Ventricular/cirurgia , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Ablação por Cateter/efeitos adversos , Endocárdio/patologia , Endocárdio/fisiopatologia , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Pericárdio/patologia , Pericárdio/fisiopatologia , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
9.
J Cardiovasc Electrophysiol ; 30(6): 865-876, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30834593

RESUMO

INTRODUCTION: Nonpulmonary vein (non-PV) triggers of atrial fibrillation (AF) are targets for ablation but their localization remains challenging. The aim of this study was to describe P-wave (PW) morphologic characteristics and intra-atrial activation patterns and timing from multipolar coronary sinus (CS) and crista terminalis (CT) catheters that localize non-PV triggers. METHODS AND RESULTS: Selective pacing from six right and nine left atrial common non-PV trigger sites was performed in 30 consecutive patients. We analyzed 12 lead ECG features based on PW duration, amplitude and morphology, and patterns and timing of multipolar activation for all 15 sites. Regionalization and then precise localization required criteria present in at least 70% of assessments at each pacing site. The algorithm was then prospectively evaluated by four blinded observers in a validation cohort of 18 consecutive patients undergoing the same pacing protocol and 60 consecutive patients who underwent successful non-PV trigger ablation. The algorithm for site regionalization included 1) negative PW in V1, ≥30 µV change in PW amplitude across the leads V1-V3, and PW duration ≤100 milliseconds in lead 2 and 2) unique intra-atrial activation patterns and timing noted in the multipolar catheters. Specific ECG and intra-atrial activation timing characteristics included in the algorithm allowed for more precise site localization after regionalization. In the prospective evaluation, the algorithm identified the site of origin for 72% of paced and 70% of spontaneous non-PV trigger sites. CONCLUSION: An algorithm based on PW morphology and intra-atrial multipolar activation pattern and timing can help identify non-PV trigger sites of origin.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
10.
Europace ; 21(7): 1106-1115, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30887036

RESUMO

AIMS: Inadvertent puncture of the aortic root (AR) is a well-known complication of transseptal puncture (TSP). Strategies for handling of this potentially lethal complication have not been identified yet. In this study, we present typical anatomical locations and clinical management of aortic root puncture (ARP) due to TSP. METHODS AND RESULTS: All patients with ARP were retrospectively collected from seven hospitals. Aortic root puncture was identified and classified regarding angiographical and intraoperative findings in cardiac surgery: (i) TSP from the right atrium (RA) to the non-coronary sinus (NCS), (ii) TSP from RA to the non-coronary sinutubular junction (STJ), and (iii) TSP from RA to the ascending aorta (AA). A total of 24 patients with inadvertent ARP were identified. In 19 patients, penetration of the aorta was accomplished by the inner dilator, in 5 patients by the complete sheath. Previous cardiac surgery had been performed in six patients. There were 13 RA-to-NCS punctures, 2 RA-to-STJ punctures, and 9 RA-to-AA punctures. No cardiac tamponade (CT) occurred in patients with RA-to-NCS and RA-to-STJ punctures. In 8 of 9 patients with RA-to-AA puncture, CT occurred immediately requiring urgent pericardiocentesis and surgical repair. Two patients died after surgical repair. In the 16 patients without surgical therapy, no shunt from the AR to the RA was observed 3 months after the procedure. CONCLUSION: Aortic root puncture due to mislead TSP via NCS or STJ is usually not associated with a severe clinical course while ARP into the AA via the epicardial space generally leads to CT requiring surgical repair.


Assuntos
Aorta Torácica/lesões , Septo Interatrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Punções/efeitos adversos , Angiografia , Feminino , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
J Cardiovasc Electrophysiol ; 29(7): 958-965, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29858877

RESUMO

INTRODUCTION: To assess the predictors of hemoptysis using second-generation cryoballoon (CB). METHODS: Thirty patients with hemoptysis after second-generation CB ablation and 60 age-, gender-, and body mass index-matched controls were recruited. Anatomic parameters were obtained from preprocedural cardiac computed tomography (CT). Pulmonary vein isolation was performed with 28-mm balloon using single 3-minute freeze technique. RESULTS: Clinical and procedural characteristics were similar between the groups. A shorter distance between left superior PV (LSPV) and left main bronchus (LMB) was associated with hemoptysis (7.8 ± 4.3 mm vs. 12.5 ± 3.5 mm, P < 0.001), whereas no significant difference in the distance between right superior PV (RSPV) and right main bronchus (RMB) was found between groups (11.9 ± 3.5 mm vs. 12.9 ± 4.6 mm, P = 0.089). Additionally, the mean thickness of the connective tissue interposed between RSPV and RMB was significantly thicker than that between LSPV and LMB in both groups (both P < 0.001). A stepwise logistic multivariate analysis identified only the LMB-LSPV distance as an independent predictor of hemoptysis (odd ratio [OR] 2.676; 95% CI 1.121-4.843, P < 0.001). A cutoff value ≤ 9.5 mm predicted hemoptysis after CB ablation with 93.8% sensitivity and 75.0% specificity. CONCLUSION: Hemoptysis is a relatively rare event following second-generation CB ablation. The bronchi location obtained from CT aids in identifying high-risk population for the complication.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Criocirurgia/efeitos adversos , Hemoptise/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Idoso , Feminino , Seguimentos , Hemoptise/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
12.
Europace ; 20(4): 673-681, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28160481

RESUMO

Aims: We sought to investigate the clinical, electrocardiographic, and electrophysiological characteristics of left upper septal fascicular ventricular tachycardia (LUS-VT). Methods and results: Eleven consecutive patients with LUS-VT were identified among 196 patients with left fascicular ventricular tachycardia (VT). Clinical VTs presented as paroxysmal in 8 patients and incessant in 3 patients. Six patients had previous left posterior fascicular VT ablation history. All VTs had narrow QRS complexes with QRS duration of 101.1 ± 9.2 ms. The frontal QRS axis was normal or right deviation. Precordial morphology was either right bundle branch block type or similar to that of sinus rhythm. A retrograde His with H-V interval of 21.9 ± 7.2 ms was recorded during VT. The earliest Purkinje potential (PP) to QRS interval during VT averaged 35.7 ± 4.5 ms. Clear diastolic potentials (DPs) with high frequency and low amplitude were found in only one patient. Ten patients were managed successfully by 11 ablation sessions, and 1 patient declined ablation. Successful targets at the left upper septum were sites with the earliest PP (9 cases) or with DP (1 case) during VT. After ablation, 2 cases (10%) developed new left anterior hemiblock or incomplete left bundle branch block. No VT recurred during a median follow-up period of 3.2 (range 1.0-12.7) years. Conclusion: LUS-VT presented as narrow QRS complex tachycardia. Some LUS-VTs occurred after ablation targeting left posterior fascicular VT. The VTs can be managed successfully by focal ablation at the left upper septum with a mild risk of fascicular injury.


Assuntos
Potenciais de Ação , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ramos Subendocárdicos/fisiopatologia , Taquicardia Ventricular/diagnóstico , Adolescente , Adulto , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Ramos Subendocárdicos/cirurgia , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
13.
Europace ; 20(10): 1666-1674, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29244066

RESUMO

Aims: We aimed to examine the electrocardiographic and electrophysiologic characteristics of anterograde-conducting decremental accessory pathways (DAP) and to identify surrogate criteria to distinguish short atrioventricular (SAV) DAP from atriofascicular (AF) AP and long atrioventricular (LAV) DAP. Methods and results: We identified all patients with DAPs and analysed electrocardiographic and electrophysiologic characteristics. Distal insertion sites were examined using existing criteria, including V-H interval, ventricular activation at the right ventricular apex, and around tricuspid annulus during antidromic atrioventricular re-entrant tachycardia (A-AVRT) or complete pre-excitation and evaluated the AV node-like properties according to the response to adenosine and radiofrequency ablation. Out of 45 patients with DAPs, 28 (62.2%) had SAV-DAP (13 with definite AF-AP, 2 with definite LAV-DAP, 2 indeterminate). In all, 50% of SAV-DAPs and 53.3% of AF-AP/LAV-DAPs had 'rS' pattern in lead III. Longer QRS duration (159.9 ± 17.4 ms vs. 139.2 ± 14.3 ms, P < 0.0001) during full pre-excitation or A-AVRT differentiated SAV-DAP from AF-AP. The QRS-V(His) interval was longer for those with SAV-DAP compared vs. AF-AP/LAV-DAP (45.3 ± 2.4 ms vs. 22.9 ± 2.5 ms, P < 0.0001) and a cut-off value of 33.0 ms differentiated the two (sensitivity 81.3%, specificity 87.5%). Conclusion: The majority of the SAV-DAPs are located at the TA free wall. An 'rS' pattern in lead III is frequently seen in SAV-DAP as well as AF-AP/LAV-DAPs. Measuring the QRS-V(His) interval would be helpful to distinguish SAV-DAP from AF-AP/LAV-DAP.


Assuntos
Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação/fisiologia , Feixe Acessório Atrioventricular/classificação , Adolescente , Adulto , Idoso , Criança , Anomalia de Ebstein/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
14.
Pacing Clin Electrophysiol ; 41(1): 14-21, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29087000

RESUMO

OBJECTIVE: The study sought to evaluate the procedural and biophysical factors related to acute pulmonary vein isolation (PVI) guided by real-time pulmonary vein (PV) potential recordings. METHODS: A total of 180 consecutive patients with drug-resistant atrial fibrillation (AF) undergoing CB2 (second-generation version of cryoballoon) ablation were enrolled. Real-time monitoring of PV potentials was obtained using an inner lumen spiral mapping catheter. RESULTS: Acute isolation was achieved in all PVs without touch-up ablation. Real-time assessment of PV disconnection was possible in 611 of 711 (85.9%) PVs. A total of 617 (86.8%) PVs were isolated during the initial freeze. Longer time cycle integration (TCI) (TTI * freeze cycle, TCI) (254.6 ± 112.8 seconds vs 74.1 ± 59.7 seconds, P < 0.001), time to isolation (TTI) (94.3 ± 34.0 seconds vs 46.3 ± 26.2 seconds, P < 0.001), higher nadir temperature (-45.5 ± 5.3°C vs -50.4 ± 5.5°C, P < 0.001), longer time to -40°C (77.3 ± 22.7 seconds vs 55.7 ± 23.2 seconds, P < 0.001), faster interval rewarming time at 0°C (9.4 ± 4.3 seconds vs 12.4 ± 4.9 seconds, P = 0.008), and total balloon rewarming time (38.1 ± 11.6 seconds vs 47.7 ± 14.0 seconds, P = 0.003) were observed in PVs with acute reconduction. TTI ≤ 65 seconds predicted absence of acute reconnection with 84.2% sensitivity and 75.7% specificity, whereas TCI ≤ 119 seconds presented 94.7% sensitivity and 80.2% specificity. At a mean follow-up of 4.7 ± 1.4 months, 82.2% of patients were free of AF. None of those with PV reconnections suffered from AF recurrences. CONCLUSIONS: The ablation using CB2 is effective in achieving acute PVI. Real-time assessment of PVI could be achieved during CB application in 86% of PVs. The incidence of spontaneous PV reconnection is very low, observed in just 3% of isolated PVs. TTI ≤ 65 seconds and TCI ≤ 119 seconds predicted absence of acute PV reconnection. Although they may identify effective cryoapplications in the acute phase, their performance still needs to be verified in the long term.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 41(6): 635-642, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29603258

RESUMO

INTRODUCTION: The "Crosstalk" technique: if pulmonary vein isolation (PVI) of the superior one is not achieved due to a gap in the inferior part, it could be done during inferior vein cryoablation. This maneuver minimizes the total energy delivery time and number of lesions. We aimed to correlate the likelihood of crosstalk phenomenon with certain anatomic characteristics. METHODS: A total of 676 patients undergoing a first ablation procedure for paroxysmal or persistent atrial fibrillation (470 first-generation cryoballoon [CB] and 206 second-generation CB) between June 2014 and December 2016 were included. RESULTS: "Crosstalk" phenomenon occurred in 32 patients (18 first-generation CB, 14 second-generation CB). Compared to 54 control patients without crosstalk, the angle between left superior pulmonary vein (LSPV) and left atrial (LA) roof-plane, left pulmonary common ostia were significant parameters associated with crosstalk (odds ratio [OR] = 1.20, ±95% confidence interval [CI]: 1.11-1.31, P < 0.001; OR = 5.67, ±95% CI: 1.08-28.69, P = 0.04). As for angle between LSPV and LA roof-plane, the cut-off value was 28.68° with a sensitivity of 72.22%, a specificity of 81.25%, and an area under the receiver operating characteristic curve of 0.87 to predict the possibility of crosstalk technique application to get isolated in LSPV. Among the crosstalk group, there was no statistical difference between first-generation CB and second-generation CB in pulmonary anatomic characteristics. CONCLUSION: Crosstalk technique can be effective in patients with AF undergoing CB ablation using with both first and second-generation CBs. Anatomic characteristics predictive of crosstalk include a left common ostia and smaller angle between the LSPV and LA roof-plane.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Eletrocardiografia , Desenho de Equipamento , Humanos , Imageamento Tridimensional , Iohexol/análogos & derivados , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
Europace ; 19(12): 2015-2022, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27965318

RESUMO

AIMS: We sought to investigate focal atrial tachycardias (ATs) in patients with congenitally corrected transposition of the great arteries (ccTGA). METHODS AND RESULTS: We identified three cases of focal ATs with ccTGA from 2007 to 2015. The clinical findings, electrocardiography, electrophysiological features, and ablation were reported. All three cases had {S,L,L}-type ccTGA. The AT P waves shared the following features: narrow in width, positive in leads I and aVL, and negative/positive in lead V1. All ATs had focal activation pattern with early activation at the anteroseptal area, and further mapping demonstrated earliest atrial activation (EAA) inside the pulmonary sinus cusps (PSCs), especially the right PSC. In Cases 1 and 2, double potentials were recorded at the EAA sites. Conduction delay between the two potentials during atrial extrastimulus was observed. After successful ablation, the second potential during sinus rhythm was further delayed in Case 1 and was eliminated in Case 2. However, only one potential was recorded in Case 3. All three cases were successfully managed by ablating the sites with EAA, which preceded the P-wave onset by 60, 80, and 42 ms, respectively. During ablation, no junctional rhythm was observed. Incomplete left bundle branch block was induced during mapping in Case 1, but no other complications occurred. All patients were free from tachycardia during follow-up periods of 36, 7, and 5 months, respectively. CONCLUSION: Anteroseptal AT in patients with ccTGA could be eliminated by ablation inside the PSC.


Assuntos
Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Artéria Pulmonar/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Transposição dos Grandes Vasos/complicações , Potenciais de Ação , Adolescente , Adulto , Ablação por Cateter/efeitos adversos , Transposição das Grandes Artérias Corrigida Congenitamente , Feminino , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Artéria Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/complicações , Taquicardia Supraventricular/fisiopatologia , Tomografia Computadorizada por Raios X , Transposição dos Grandes Vasos/diagnóstico , Transposição dos Grandes Vasos/fisiopatologia , Resultado do Tratamento , Adulto Jovem
17.
J Cardiovasc Electrophysiol ; 26(8): 845-852, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25917416

RESUMO

BACKGROUND: The accessory pathway (AP) connecting the right atrial appendage (RAA) and the right ventricle (RV) is rare. OBJECTIVE: We sought to investigate the feature of the AP connecting the RAA and the RV and the efficacy of radiofrequency catheter ablation via the endocardial access. METHODS: We retrospectively analyzed 14 consecutive patients with 14 APs connecting the RAA and the RV managed by 15 procedures between January 2003 and December 2014. RESULTS: Ten patients presented as preexcitation during sinus rhythm. All APs had retrograde conduction. None had either antegrade or retrograde decremental conduction property. Ablation targeting the sites at the tricuspid annulus failed in all patients. They were successfully managed by ablating the atrial insertion sites with a median of 10.5 (range 5-28) radiofrequency applications. Electrograms at the successful target showed high amplitude atrial electrogram and low amplitude or no ventricular electrogram. The atrial insertion sites were at the floor of the RAA in 10 patients and inside the lower lobe of the RAA in the remaining 4 patients. The shortest distance between the successful target and the tricuspid annulus in the right anterior oblique projection was 19.7 ± 4.0 mm. There were no complications or recurrences during a median follow-up period of 4.3 (range 0.2-11.8) years. CONCLUSION: The APs connecting the RAA and the RV had typical conduction properties. The atrial insertion site favored the floor and the lower lobe of the RAA. Ablation targeting the atrial insertion sites was effective and safe, albeit multiple radiofrequency applications were needed.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Arritmias Cardíacas/cirurgia , Apêndice Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/cirurgia , Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Apêndice Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Pacing Clin Electrophysiol ; 38(9): 1073-81, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26096255

RESUMO

BACKGROUND: Cryoballoon ablation is an alternative for the treatment of atrial fibrillation (AF). We assess the relationship among pulmonary vein (PV) electrophysiology, balloon temperature, and persistent PV isolation (PVI), and report procedural properties, safety, and efficacy of this technique in a Chinese center for the first time. METHODS: A total of 70 patients with paroxysmal (n = 57) and persistent (n = 13) AF were consecutively enrolled. PVI was performed with cryoballoon catheter. Real-time recording of dissociation of PV potentials was attempted using a circumferential mapping catheter. RESULTS: Successful PVI was achieved in 274 of 282 (97.2%) PVs. Procedural duration was 115.2 ± 24.8 minutes and fluoroscopy time was 29.6 ± 8.9 minutes. Real-time PV potential recording was achieved in 232 (84.3%) PVs. Regarding time to isolation, a cut-off value of less than 60 seconds was predictive of persistent PVI with a sensitivity of 0.76 and specificity of 0.82 (area under curve = 0.835; P < 0.0001). The nadir balloon temperature was significantly lower in PVs without early reconduction (-46.3 ± 0.5°C vs -40.2 ± 1.3°C, P < 0.0001). However, there was an insignificant trend that the balloon temperature at isolation was higher in PVs without reconduction (-33.9 ± 0.7°C vs -36.4 ± 2.0°C, P = 0.14). The overall complication rate was 5.7%. After a median follow-up of 6.5 (range 3.2-14.9) months, 76% of patients were free of AF recurrence with a blanking period of 3 months. CONCLUSIONS: Real-time PV potentials can be recorded in most PVs. The time to isolation is predictive of the persistency of PVI. The nadir balloon temperature, not the balloon temperature at isolation, is significantly lower in PVs without reconduction.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Cateterismo Cardíaco/instrumentação , China , Criocirurgia/instrumentação , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia
19.
Clin Cardiol ; 47(1): e24180, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37889106

RESUMO

BACKGROUND: Radiofrequency (RF) catheter ablation of para-Hisian accessory pathways (APs) can be challenging due to proximity to the conduction system. METHODS: A total of 30 consecutive patients with para-Hisian AP were enrolled for ablation in three centers, 12 (40%) of whom had previously failed attempted ablation from the inferior vena cava (IVC) approach. Ablation was preferentially performed using a superior approach from the superior vena cava (SVC) in all patients. RESULTS: The para-Hisian AP was eliminated from the SVC approach in 28 of 30 (93.3%) patients. In the remaining two patients, additional ablation from IVC was required to successfully eliminate the AP. There were two patients experienced reversible complete atrial-ventricular block and PR prolongation during the first RF application. Long-term freedom from recurrent arrhythmia was achieved in 29 (96.7%) patients over a mean follow-up duration of 15.6 ± 4.6 months. CONCLUSION: Catheter ablation of para-Hisian AP from above using a direct SVC approach is both safe and effective, and should be considered especially in patients who have failed conventional ablation attempts from IVC approach.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Humanos , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia , Resultado do Tratamento , Fascículo Atrioventricular , Sistema de Condução Cardíaco/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/efeitos adversos
20.
Heart Rhythm ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38588992

RESUMO

BACKGROUND: The aorta-mitral annulus conjunction (AMC) is an uncommon site of origin of focal atrial tachycardias (ATs). Hence, the electrophysiological and ablation target characteristics are poorly described. OBJECTIVE: The purpose of this study was to describe the characteristics of AMC AT in detail. METHODS: The study enrolled 650 patients with AT, 21 (3.2%) of whom had AT originating from the AMC. A comprehensive evaluation, including electrocardiography, electrophysiology study, computed tomography scan, and intracardiac echocardiography, was performed. RESULTS: The majority (90.5%) of ATs occurred spontaneously. The mean age of this group was 48.9 ± 21.6 years, with 12 being female (57.1%). Seventeen patients had a typical biphasic P wave with a prominent positive component. The earliest activation site in the right atrium was near the His bundle, with average activation -10.3 ± 6.0 ms preceding the P wave. The successful ablation targets were distributed as follows: 1 case at 9 o'clock, 6 cases at 10 o'clock, 7 cases at 11 o'clock, 6 cases at 12 o'clock, and 1 case in the left coronary cusp. The local AMC potential differed from the commonly perceived annular potential and was characterized by a large A and a small V (atrial-to-ventricular ratio > 1). The angle of encroachment on the left atrial anterior wall, compressed by the left coronary cusp, was significantly smaller in the AMC AT group than in the control group, which may have contributed to the arrhythmia substrate (141.7° ± 11.5° vs 155.2° ± 13.9°; P = .026). CONCLUSION: A new strategy for mapping AMC ATs has been introduced. The ablation target should have an atrial-to-ventricular ratio of >1.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA