Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Proc Natl Acad Sci U S A ; 118(30)2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-34301871

RESUMO

Cadherin cell-cell adhesion proteins play key roles in tissue morphogenesis and wound healing. Cadherin ectodomains bind in two conformations, X-dimers and strand-swap dimers, with different adhesive properties. However, the mechanisms by which cells regulate ectodomain conformation are unknown. Cadherin intracellular regions associate with several actin-binding proteins including vinculin, which are believed to tune cell-cell adhesion by remodeling the actin cytoskeleton. Here, we show at the single-molecule level, that vinculin association with the cadherin cytoplasmic region allosterically converts weak X-dimers into strong strand-swap dimers and that this process is mediated by myosin II-dependent changes in cytoskeletal tension. We also show that in epithelial cells, ∼70% of apical cadherins exist as strand-swap dimers while the remaining form X-dimers, providing two cadherin pools with different adhesive properties. Our results demonstrate the inside-out regulation of cadherin conformation and establish a mechanistic role for vinculin in this process.


Assuntos
Caderinas/química , Caderinas/metabolismo , Actinas/metabolismo , Animais , Adesão Celular , Citoesqueleto , Cães , Células Madin Darby de Rim Canino , Miosina Tipo II/metabolismo , Ligação Proteica , Vinculina/metabolismo
2.
J Chem Phys ; 148(12): 123301, 2018 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-29604850

RESUMO

Dynamic Force Spectroscopy (DFS) is a widely used technique to characterize the dissociation kinetics and interaction energy landscape of receptor-ligand complexes with single-molecule resolution. In an Atomic Force Microscope (AFM)-based DFS experiment, receptor-ligand complexes, sandwiched between an AFM tip and substrate, are ruptured at different stress rates by varying the speed at which the AFM-tip and substrate are pulled away from each other. The rupture events are grouped according to their pulling speeds, and the mean force and loading rate of each group are calculated. These data are subsequently fit to established models, and energy landscape parameters such as the intrinsic off-rate (koff) and the width of the potential energy barrier (xß) are extracted. However, due to large uncertainties in determining mean forces and loading rates of the groups, errors in the estimated koff and xß can be substantial. Here, we demonstrate that the accuracy of fitted parameters in a DFS experiment can be dramatically improved by sorting rupture events into groups using cluster analysis instead of sorting them according to their pulling speeds. We test different clustering algorithms including Gaussian mixture, logistic regression, and K-means clustering, under conditions that closely mimic DFS experiments. Using Monte Carlo simulations, we benchmark the performance of these clustering algorithms over a wide range of koff and xß, under different levels of thermal noise, and as a function of both the number of unbinding events and the number of pulling speeds. Our results demonstrate that cluster analysis, particularly K-means clustering, is very effective in improving the accuracy of parameter estimation, particularly when the number of unbinding events are limited and not well separated into distinct groups. Cluster analysis is easy to implement, and our performance benchmarks serve as a guide in choosing an appropriate method for DFS data analysis.

3.
Nano Lett ; 12(7): 3731-5, 2012 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-22703235

RESUMO

We describe a new technique, standing wave axial nanometry (SWAN), to image the axial location of a single nanoscale fluorescent object with sub-nanometer accuracy and 3.7 nm precision. A standing wave, generated by positioning an atomic force microscope tip over a focused laser beam, is used to excite fluorescence; axial position is determined from the phase of the emission intensity. We use SWAN to measure the orientation of single DNA molecules of different lengths, grafted on surfaces with different functionalities.


Assuntos
DNA/química , Fluorescência , Nanotecnologia/métodos , Microscopia de Força Atômica , Nanotecnologia/instrumentação , Conformação de Ácido Nucleico , Propriedades de Superfície
4.
Proc Natl Acad Sci U S A ; 106(1): 127-32, 2009 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-19109435

RESUMO

A simple genetic tag-based labeling method that permits specific attachment of a fluorescence probe near the C terminus of virtually any subunit of a protein complex is implemented. Its immediate application to yeast RNA polymerase II (pol II) enables us to test various hypotheses of RNA exit channel by using fluorescence resonance energy transfer (FRET) analysis. The donor dye is labeled on a site near subunit Rpb3 or Rpb4, and the acceptor dye is attached to the 5' end of RNA transcript in the pol II elongation complex. Both in-gel and single-molecule FRET analysis show that the growing RNA is leading toward Rpb4, not Rpb3, supporting the notion that RNA exits through the proposed channel 1. Distance constraints derived from our FRET results, in conjunction with triangulation, reveal the exit track of RNA transcript on core pol II by identifying amino acids in the vicinity of the 5' end of RNA and show that the extending RNA forms contacts with the Rpb7 subunit. The significance of RNA exit route in promoter escape and that in cotranscriptional mRNA processing is discussed.


Assuntos
Transferência Ressonante de Energia de Fluorescência , RNA Polimerase II/genética , Proteínas de Saccharomyces cerevisiae/genética , Transcrição Gênica , Corantes Fluorescentes , Técnicas de Sonda Molecular , Saccharomyces cerevisiae/química , Saccharomyces cerevisiae/genética
5.
Artigo em Inglês | MEDLINE | ID: mdl-29075581

RESUMO

Atomic force microscopes (AFMs) are widely used to study molecular interactions with piconewton force sensitivity. In an AFM, interaction forces are measured by reflecting a laser beam off a cantilever onto a position sensitive detector and monitoring cantilever deflection. Precise measurements of interaction forces rely on accurately determining the optical lever sensitivity, i.e., the relationship between cantilever deflection and changes in detector voltage. The optical lever sensitivity is measured by pressing the cantilever against a hard substrate using a piezoactuator and recording the resulting change in detector voltage. However, nonlinearities in the motion of commonly used open-loop piezo actuators introduce significant errors in measured optical lever sensitivities. Here, the authors systematically characterize the effect of piezo actuator hysteresis and creep on errors in optical lever sensitivity and identify measurement conditions that minimize these errors.

6.
Sci Adv ; 2(7): e1600014, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27419232

RESUMO

Prion protein (PrP) misfolding and oligomerization are key pathogenic events in prion disease. Copper exposure has been linked to prion pathogenesis; however, its mechanistic basis is unknown. We resolve, with single-molecule precision, the molecular mechanism of Cu(2+)-induced misfolding of PrP under physiological conditions. We also demonstrate that misfolded PrPs serve as seeds for templated formation of aggregates, which mediate inflammation and degeneration of neuronal tissue. Using a single-molecule fluorescence assay, we demonstrate that Cu(2+) induces PrP monomers to misfold before oligomer assembly; the disordered amino-terminal region mediates this structural change. Single-molecule force spectroscopy measurements show that the misfolded monomers have a 900-fold higher binding affinity compared to the native isoform, which promotes their oligomerization. Real-time quaking-induced conversion demonstrates that misfolded PrPs serve as seeds that template amyloid formation. Finally, organotypic slice cultures show that misfolded PrPs mediate inflammation and degeneration of neuronal tissue. Our study establishes a direct link, at the molecular level, between copper exposure and PrP neurotoxicity.


Assuntos
Cobre/química , Proteínas Priônicas/metabolismo , Animais , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Humanos , Técnicas In Vitro , Camundongos , Camundongos Endogâmicos C57BL , Microscopia de Força Atômica , Proteínas Priônicas/química , Proteínas Priônicas/genética , Proteínas Priônicas/toxicidade , Agregados Proteicos/fisiologia , Ligação Proteica , Domínios Proteicos , Dobramento de Proteína , Proteína Quinase C-delta/metabolismo , Proteínas Recombinantes/sangue , Proteínas Recombinantes/química , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/toxicidade
7.
Structure ; 18(1): 17-27, 2010 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-20152149

RESUMO

Single particle reconstruction from cryoelectron microscopy images, though emerging as a powerful means in structural biology, is faced with challenges as applied to asymmetric proteins smaller than megadaltons due to low contrast. Zernike phase plate can improve the contrast by restoring the microscope contrast transfer function. Here, by exploiting simulated Zernike and conventional defocused cryoelectron microscope images with noise characteristics comparable to those of experimental data, we quantified the efficiencies of the steps in single particle analysis of ice-embedded RNA polymerase II (500 kDa), transferrin receptor complex (290 kDa), and T7 RNA polymerase lysozyme (100 kDa). Our results show Zernike phase plate imaging is more effective as to particle identification and also sorting of orientations, conformations, and compositions. Moreover, our analysis on image alignment indicates that Zernike phase plate can, in principle, reduce the number of particles required to attain near atomic resolution by 10-100 fold for proteins between 100 kDa and 500 kDa.


Assuntos
Microscopia Crioeletrônica/métodos , Muramidase/análise , RNA Polimerase II/análise , Receptores da Transferrina/análise , Bacteriófago T7 , Muramidase/ultraestrutura , RNA Polimerase II/ultraestrutura , Receptores da Transferrina/ultraestrutura , Saccharomyces cerevisiae
8.
IEEE Trans Nanobioscience ; 8(2): 113-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19336290

RESUMO

PURPOSE: A modified laser capture microdissection (LCM) system is developed to improve resolution to 400 nm, using a laser light (808 nm) transmitted by a near-field tip probe. MATERIALS AND METHODS: Using a 150-nm aperture to heat an ethylene vinyl acetate (EVA) film, melted spots on the average of 400 nm in diameter are generated on the underlying target composed of a 20-nm gold-particle monolayer. The near-field tip probe composed of fiber is set on a 2-D nanometer piezoactuator (PZT) for precise capturing of the monolayer of gold particles. The monolayer of gold particles under the target is bound to the EVA film using a laser, while the remaining EVA film stays on the monolayer. RESULTS: The diameter of the melted spots as small as 400 nm are produced and details are provided that demonstrate the feasibility of the nanooperation of this new LCM system. CONCLUSION: The new LCM system successfully captures nanoparticles and improves resolution of microdissection to 400 nm. With this LCM system, the isolation of a single organelle or bacterium is possible.


Assuntos
Microdissecção/instrumentação , Micromanipulação/instrumentação , Nanopartículas/química , Nanotecnologia/instrumentação , Pinças Ópticas , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA