Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Sensors (Basel) ; 24(17)2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39275655

RESUMO

In this study, nanoporous gold (NPG) was deposited on a screen-printed carbon electrode (SPCE) by the dynamic hydrogen bubble template (DHBT) method to prepare an electrochemical sensor for the simultaneous determination of Pb2+ and Cu2+ by square wave anodic stripping voltammetry (SWASV). The electrodeposition potential and electrodeposition time for NPG/SPCE preparation were investigated thoroughly. Scanning electron microscopy (SEM) and energy-dispersive X-ray diffraction (EDX) analysis confirmed successful fabrication of the NPG-modified electrode. Electrochemical characterization exhibits its superior electron transfer ability compared with bare and nanogold-modified electrodes. After a comprehensive optimization, Pb2+ and Cu2+ were simultaneously determined with linear range of 1-100 µg/L for Pb2+ and 10-100 µg/L for Cu2+, respectively. The limits of detection were determined to be 0.4 µg/L and 5.4 µg/L for Pb2+ and Cu2+, respectively. This method offers a broad linear detection range, a low detection limit, and good reliability for heavy metal determination in drinking water. These results suggest that NPG/SPCE holds great promise in environmental and food applications.

2.
Sci Rep ; 14(1): 18433, 2024 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-39117723

RESUMO

Electrochemical detection is favorable for the rapid and sensitive determination of heavy metal cadmium. However, the detection sensitivity needs to be further improved, and a portable, low-cost device is needed for on-site detection. Herein, an in-situ bismuth modified pre-anodized screen-printed carbon electrode (SPCE) was developed for Cd2+ determination by square wave anodic stripping voltammetry (SWASV). The in-situ bismuth modification enhances the enrichment of Cd2+, and together with pre-anodization improve the electron transfer rate of electrode, thus enhancing the detection sensitivity. The electrode modification method combines pre-anodization and in-situ bismuth deposition, which is very easy and effective. Furthermore, a self-made PSoC Stat potentiostat coupled with a stirring device was fabricated for portable and low-cost electrochemical detection. After comprehensive optimization, the developed method can reach a testing time of 3 min, a detection limit of 3.55 µg/L, a linear range of 5-100 µg/L, and a recovery rate of 91.7-107.1% in water and rice samples for Cd2+ determination. Therefore, our method holds great promise for the rapid, sensitive and on-site determination of Cd2+ in food samples.


Assuntos
Bismuto , Cádmio , Técnicas Eletroquímicas , Eletrodos , Oryza , Cádmio/análise , Oryza/química , Bismuto/química , Bismuto/análise , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Água/química , Água/análise , Poluentes Químicos da Água/análise , Limite de Detecção , Contaminação de Alimentos/análise
3.
Biosensors (Basel) ; 13(1)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36671965

RESUMO

In this study, a screen-printed carbon electrode (SPCE) based on in situ deposition modification was developed for the sensitive, rapid, easy and convenient determination of As(III) in water and tea by linear sweep anodic stripping voltammetry (LSASV). The screen-printed carbon electrodes were placed in a solution consisting of As(III) solution, chlorauric acid and L-cysteine. Under certain electrical potential, the chloroauric acid was reduced to gold nanoparticles (AuNPs) on the SPCE. L-cysteine was self-assembled onto AuNPs and promoted the enrichment of As(III), thus enhancing the determination specificity and sensitivity of As(III). The method achieved a limit of determination (LOD) of 0.91 ppb (µg L-1), a linear range of 1~200 µg L-1, an inter-assay coefficient of variation of 5.3% and good specificity. The developed method was successfully applied to the determination of As(III) in tap water and tea samples, with a recovery rate of 93.8%~105.4%, and further validated by inductively coupled plasma mass spectrometry (ICP-MS). The developed method is rapid, convenient and accurate, holding great promise in the on-site determination of As(III) in tap water and tea leaves, and it can be extended to the detection of other samples.


Assuntos
Ouro , Nanopartículas Metálicas , Ouro/química , Carbono/química , Cisteína , Água , Técnicas Eletroquímicas/métodos , Nanopartículas Metálicas/química , Eletrodos , Chá
4.
Sci Rep ; 12(1): 8796, 2022 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-35614117

RESUMO

Steel bridge deck pavement has always been a key and difficult point in the construction of long-span bridges. In practical engineering, common paving material is asphalt, and serious damage is caused on the pavement layer in the early stage. In this study, a high-performance high-content hybrid fibre polymer concrete was used as the paving material. A test was conducted on the small beam of the composite structure formed by the pavement layer and steel plate, and a positive/negative bending moment test was conducted to analyse the stiffness and bearing capacity of the composite structure. As revealed in the research results, the flexural and tensile stiffness of the structure and the bearing capacity of the composite structure showed superior performance, increased significantly with the pavement thickness, but increased slowly after the pavement thickness exceeded 80 mm and the increase in thickness contributed little to the bearing capacity. Under the simulated action of a positive/negative bending moment, the pavement layer still exhibited certain ductile failure features when the structure was bearing an ultimate load. This proves that high-content hybrid fibre polymer concrete exhibits suitable mechanical properties for steel bridge deck pavement.


Assuntos
Materiais de Construção , Aço , Engenharia , Polímeros , Resistência à Tração
5.
Materials (Basel) ; 14(23)2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34885455

RESUMO

Polymer-modified cement has found numerous applications due to its excellent tensile strength. When cement was modified with a single polymer, its tensile strength and performance marginally increased. However, when a small amount of the flexible polymer latex was added to cement, the mechanical performance of cement considerably improved. In this study, single-graded copolymer-modified pervious concrete was prepared by mixing styrene-butadiene rubber (SBR) with different acrylate polymers, and its mechanical performance and durability were systematically studied through mechanical tests and theoretical analyses. The main findings are as follows: (1) When a waterborne emulsion was added, the freeze resistance of cement concrete increased, and its mass loss rate decreased. Cement concrete with two latexes had higher sulphate corrosion resistance and substantially lower dry shrinkage strain than ordinary cement concrete. (2) Through scanning electron microscopy, the microstructural changes in the cement binder, ordinary polymer-modified concrete, and the copolymer-modified cement concrete used in this study were observed, and the findings were compared with those reported in the literature. (3) Single-graded copolymer-modified pervious concrete exhibited excellent shrinkage performance. This study showed that single-graded copolymer-modified pervious concrete satisfied the performance requirements for use as a paving material for special cases.

6.
Materials (Basel) ; 14(21)2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34771757

RESUMO

Polymer-modified concrete and fiber concrete are two excellent paving materials that improve the performance of some concrete, but the performance of single application material is still limited. In this paper, polymer-modified concrete with strong deformation and fiber concrete with obvious crack resistance and reinforcement effect were compounded by using the idea of composite material design so as to obtain a high-performance pavement material. The basic mechanical properties of high-content hybrid fiber-polymer-modified concrete, such as workability, compression, flexural resistance, and environmental durability (such as sulfate resistance) were studied by using the test regulations of cement concrete in China. The main results were as follows. (1) The hybrid fiber-polymer concrete displayed reliable working performance, high stiffness, and a modulus of elasticity as high as 35.93 GPa. (2) The hybrid fiber-polymer concrete had a compressive strength of 52.82 MPa, which was 31.2% higher than that of the plain C40 concrete (40.25 MPa); the strength of bending of the hybrid concrete was 11.51 MPa, 191.4% higher than that of the plain concrete (3.95 MPa). (3) The corrosion resistance value of the hybrid fiber-polymer concrete was 81.31%, indicating its adjustability to sulfate attack environments. (4) According to cross-sectional scanning electron microscope (SEM) images, the hybrid fiber-polymer concrete was seemingly more integrated with a dense layer of cementing substance on its surface along with fewer microholes and microcracks as when compared to the ordinary concrete. The research showed that hybrid fiber-polymer concrete had superior strength and environmental erosion resistance and was a pavement material with superior mechanical properties.

7.
Biosensors (Basel) ; 12(1)2021 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-35049639

RESUMO

Coronavirus disease 2019 (COVID-19) caused by the SARS-CoV-2 virus has led to a global pandemic with a high spread rate and pathogenicity. Thus, with limited testing solutions, it is imperative to develop early-stage diagnostics for rapid and accurate detection of SARS-CoV-2 to contain the rapid transmission of the ongoing COVID-19 pandemic. In this regard, there remains little knowledge about the integration of the CRISPR collateral cleavage mechanism in the lateral flow assay and fluorophotometer. In the current study, we demonstrate a CRISPR/Cas12a-based collateral cleavage method for COVID-19 diagnosis using the Cas12a/crRNA complex for target recognition, reverse transcription loop-mediated isothermal amplification (RT-LAMP) for sensitivity enhancement, and a novel DNA capture probe-based lateral flow strip (LFS) or real-time fluorescence detector as the parallel system readout facility, termed CRICOLAP. Our novel approach uses a customized reporter that hybridizes an optimized complementary capture probe fixed at the test line for naked-eye result readout. The CRICOLAP system achieved ultra-sensitivity of 1 copy/µL in ~32 min by portable real-time fluorescence detection and ~60 min by LFS. Furthermore, CRICOLAP validation using 60 clinical nasopharyngeal samples previously verified with a commercial RT-PCR kit showed 97.5% and 100% sensitivity for S and N genes, respectively, and 100% specificity for both genes of SARS-CoV-2. CRICOLAP advances the CRISPR/Cas12a collateral cleavage result readout in the lateral flow assay and fluorophotometer, and it can be an alternative method for the decentralized field-deployable diagnosis of COVID-19 in remote and limited-resource locations.


Assuntos
Teste para COVID-19 , COVID-19 , Sistemas CRISPR-Cas , COVID-19/diagnóstico , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , Sensibilidade e Especificidade
8.
Biosens Bioelectron ; 159: 112143, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32364943

RESUMO

CRISPR/Cas systems have displayed remarkable potential in developing novel biosensing applications for nucleic acid detection owing to the collateral cleavage activity of Cas effector proteins (Cas12, Cas13, etc.). Despite tremendous progress in recent years, the existing CRISPR/Cas based biosensing platforms have several limitations, including reliance on proper amplification methods, expensive fluorescence detection equipment, or lateral flow biosensor (LFB). Herein, we report a simple, inexpensive, and ultrasensitive DNA probe based LFB with CRISPR/Cas and loop-mediated Isothermal Amplification (namely CIA). The concept behind this approach is a non-detectable test line on the LFB when the Cas effector protein collaterally cleaves the cognate target and an ssDNA reporter sequence. The CIA based LFB can detect as low as a single copy cloned Pseudomonas aeruginosa acyltransferase gene, 1 cfu/ml plasmid containing E. coli DH5α pure cultures, as well as clinical samples without DNA extraction/purification or advanced apparatuses. No cross-reactivity with other non-target bacteria was observed. The naked eye result readout was obtained in 15 min of LAMP amplification, 30 min of Cas12 reaction, and 5 min of LFB readout. This platform is robust and of low cost for on-site testing.


Assuntos
Técnicas Biossensoriais , Sistemas CRISPR-Cas , Técnicas de Amplificação de Ácido Nucleico , Ácidos Nucleicos , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/normas , DNA Bacteriano , DNA de Cadeia Simples , Técnicas de Diagnóstico Molecular , Sensibilidade e Especificidade
9.
Innovation (Camb) ; 3(3): 100245, 2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35519512
10.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA