Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 101(3): 318-23, 2000 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-10645929

RESUMO

BACKGROUND: Measurements of Doppler derived coronary flow reserve (CFR) and pressure derived fractional flow reserve (FFR) for coronary stenosis assessment depend on the induction of maximal hyperemia. Adenosine is the most widely used pharmacological agent but is expensive and poorly tolerated by some patients. METHODS AND RESULTS: The objective of this study was to test the equivalency of adenosine 5'-triphosphate (ATP) to adenosine in their ability to cause maximal hyperemia as compared with the hyperemic response of complete coronary occlusion in 6 canines. Intracoronary administration of either ATP or adenosine resulted in a significant increase in CFR (2.79+/-0.64 and 2.22+/-0.7 for 10 microgram versus 4. 65+/-1.22 and 4.25+/-0.78 for 100 microgram for ATP and adenosine, respectively, P for trend <0.001) but not reaching the level of coronary occlusion (6.35+/-2.26). Additionally, FFR and CFR were measured in 35 different stenoses using ATP, adenosine, and coronary occlusion. There was an excellent linear correlation between ATP and adenosine for both CFR (R=0.934, P<0.001) and FFR (R=0.985, P<0.001). However, hyperemia with either ATP or adenosine was less than postocclusion hyperemia, resulting in significantly different reserve measurements (CFR: 1.93+/-0.66 and 2.08+/-0.81 versus 2.35+/-0.97, P<0.001; FFR: 0.62+/-0.24 and 0.63+/-0.23 versus 0.58+/-0.2, P<0.001). CONCLUSIONS: 1) Step up in dosage of ATP and adenosine beyond currently recommended clinical doses resulted in a significant increase in coronary hyperemia; 2) ATP was equivalent to adenosine for both CFR and FFR; and 3) complete coronary occlusion yielded a better hyperemic response than either drug, indicating that maximal hyperemia was not achieved by either pharmacological stimulus.


Assuntos
Trifosfato de Adenosina/farmacologia , Adenosina/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Circulação Coronária/efeitos dos fármacos , Adenosina/administração & dosagem , Trifosfato de Adenosina/administração & dosagem , Animais , Doença das Coronárias/fisiopatologia , Cães , Relação Dose-Resposta a Droga , Hiperemia/induzido quimicamente
2.
Circulation ; 102(14): 1657-63, 2000 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-11015344

RESUMO

BACKGROUND: Ultra-high-frequency (40- to 50-MHz) intravascular ultrasound (IVUS) improves image quality compared with conventional 20- to 30-MHz IVUS. However, as the frequency of IVUS increases, high-intensity backscatter from blood components may cause visual difficulties in discrimination between the lumen and arterial wall structure. The purpose of this study was to evaluate the effect of a novel blood noise reduction algorithm (BNR) on quantitative coronary ultrasound measurements. METHODS AND RESULTS: IVUS studies using a 40-MHz transducer were performed in 35 patients with coronary artery disease. A total of 620 gray-scale images (310 pairs) were processed with and without the BNR, and lumen cross-sectional area (CSA) was determined by 2 independent observers. With the BNR, the intraobserver and interobserver correlation coefficients for lumen CSA were significantly improved (0.85 to 0.99 and 0.80 to 0.98, respectively). In the 270 images (135 pairs) in which vessel wall measurements were possible, the BNR significantly improved the intraobserver and interobserver correlation coefficients for plaque plus media CSA (0.83 to 0.99 and 0.76 to 0.97, respectively), whereas no influence was observed for external elastic membrane CSA (1.00 to 1.00 and 0.99 to 0.99, respectively). CONCLUSIONS: This study demonstrates the feasibility of this novel algorithm to reduce blood noise, thereby enabling accurate lumen border delineation and providing reproducible measurements of both the lumen and plaque plus media CSAs. Incorporating a digital BNR may serve as an important adjunct to ultra-high-frequency IVUS imaging for improving accurate quantitative evaluation of vessel dimensions.


Assuntos
Algoritmos , Doença das Coronárias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Estudos de Viabilidade , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes
3.
Circulation ; 103(14): 1828-31, 2001 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-11294798

RESUMO

BACKGROUND: Intimal hyperplasia and subsequent in-stent restenosis remain a major limitation after stent implantation. In vitro cell culture studies show that low-frequency, noncavitational ultrasound energy may impact smooth muscle cell proliferation. Accordingly, we assessed the efficacy of intravascular sonotherapy treatment on intimal hyperplasia in a swine stent model. METHODS AND RESULTS: After balloon injury, biliary stents (Johnson & Johnson) were implanted in the femoral arteries of 14 swine. A total of 48 stented sites were randomized to sonotherapy or sham treatment using a custom-built, 8-French catheter intravascular sonotherapy system (URX, PharmaSonics Inc). After stent deployment, ultrasound energy (700 KHz) was applied to the treatment group for up to 5 minutes. Smooth muscle cell proliferation was assessed using bromodeoxyuridine histology preparation (BrdU) at 7 days in 28 stented sites. At 28 days, the neointimal thickness and the ratio of neointimal/stent area (percent stenosis) was calculated by histomorphometric quantification in 20 stented sites. At 7 days, percent of BrdU staining was significantly reduced in the sonotherapy group compared with the sham group (24.1+/-7.0% versus 31.2+/-3.0%, P<0.05). At 28 days, percent stenosis was significantly less in the sonotherapy group than in the sham group (36+/-24% versus 44+/-27%, P<0.05), and the mean neointimal thickness in the sonotherapy group was less than in the sham group (417+/-461 micrometer versus 643+/-869 micrometer, P=0.06). CONCLUSIONS: In this swine peripheral model, intravascular sonotherapy seemed to decelerate cellular proliferation and decrease in-stent hyperplasia. Therefore, intravascular sonotherapy may be an effective form of nonionizing energy to reduce in-stent restenosis.


Assuntos
Stents , Túnica Íntima/patologia , Terapia por Ultrassom , Animais , Divisão Celular , Artéria Femoral/patologia , Hiperplasia/terapia , Suínos , Doenças Vasculares/patologia , Doenças Vasculares/terapia
4.
Circulation ; 103(17): 2130-2, 2001 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-11331251

RESUMO

BACKGROUND: Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. METHODS AND RESULTS: Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard stent deployment techniques. The vessel volume (VV), lumen volume (LV), and volume bordered by the stent (SV) were measured using Simpson's method. The volume of plaque and neointima outside the stent (peri-stent volume, PSV) and volume of neointima within the stent (intrastent volume) were also measured. The change of each parameter during the follow-up period (follow-up minus poststent) was calculated and then divided by SV to normalize these values (designated as percent change [%]). As expected, %PSV directly correlated with %VV (P<0.0001, r=0.935), with no significant SV. A highly significant inverse correlation was seen between %PSV and the percent change of intrastent volume (P<0.0001, r=0.517). Consequently, %LV significantly correlated with peri-stent remodeling, as measured by %VV (P<0.0001, r=0.602). CONCLUSION: Positive remodeling of the vessel exterior to a coronary stent occurs to a variable degree after stent implantation. There is a distinct trade-off between positive remodeling and in-stent hyperplasia: in segments in which the degree of peri-stent remodeling is less, intrastent neointimal proliferation is greater and accompanied by more significant late lumen loss.


Assuntos
Estenose Coronária/patologia , Vasos Coronários/patologia , Stents , Idoso , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/etiologia , Estenose Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Túnica Íntima/patologia , Ultrassonografia
5.
Circulation ; 104(4): 380-3, 2001 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-11468196

RESUMO

BACKGROUND: The aim of this study was to use serial intravascular ultrasound (IVUS) to evaluate the long-term effect of stent-based 7-hexanoyltaxol (QP2, a taxane analogue) delivery on neointimal tissue growth within the stent and on vessel dimensions at the adjacent reference segments. METHODS AND RESULTS: Serial IVUS analyses (immediately after intervention and at follow-up at 8.3 months) were performed in 15 native coronary lesions treated with the QuaDS-QP2 stent. IVUS measurements were performed at 8 cross-sections in each target segment (4 cross-sections within the stent and 2 cross-sections in each reference segment). At baseline, no significant plaque protrusion or thrombus was detected in the target segment. Mild incomplete stent apposition and edge dissection were observed in one and two cases, respectively. Percent expansion of the stent (minimum stent area/average reference lumen area) was 96.0+/-21.7%. At follow-up, mean neointimal area within the stent was 1.2+/-1.3 mm(2), and mean cross-sectional narrowing (neointimal area/stent area) was 13.6+/-14.9%. At the vessel segments immediately adjacent to the stent, a significant increase in plaque area (1.9+/-2.6 mm(2), P=0.001) was observed, but vessel area remained unchanged. However, no patients showed clinically significant in-stent or edge restenosis (diameter stenosis >/=50%) during the follow-up period. CONCLUSIONS: The first human experience with the new drug-delivery stent showed a minimal amount of neointimal proliferation in the stented segment. Late lumen loss at the reference sites adjacent to the stent was acceptable and predominantly due to plaque proliferation.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Stents , Adulto , Idoso , Hidrocarbonetos Aromáticos com Pontes/farmacologia , Doença das Coronárias/tratamento farmacológico , Doença das Coronárias/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Sistemas de Liberação de Medicamentos/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Polímeros , Túnica Íntima/efeitos dos fármacos , Túnica Íntima/patologia , Ultrassonografia de Intervenção
6.
Circulation ; 100(21): 2127-30, 1999 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-10571969

RESUMO

BACKGROUND: Unprocessed ultrasound radiofrequency (RF) signal analysis has been shown to distinguish different tissue structures more reliably than gray-scale interpretation of conventional ultrasound images. METHODS AND RESULTS: The objective of this study was to test the feasibility of in vivo intravascular ultrasound (IVUS) RF signal analysis in an animal model of allograft rejection. Six cynomolgus monkeys underwent transplantation of 3-cm aortic allograft segments distal to the renal arteries from immunologically mismatched donors. IVUS imaging with a 30-MHz system was performed 84 to 105 days after the operation. RF signals were acquired from cross sections of the recipient and the allograft aortas in real time with a digitizer at 500 MHz with 8-bit resolution. Sixty-five cross sections and 68 regions of interest (31 in host aorta and 37 in allograft) were analyzed in the adventitial layer with a total number of 8568 vectors processed. For each region of interest, a weighted-average attenuation was calculated on the basis of the attenuation and length for each individual vector. Histological examination was performed at every cross section imaged by IVUS. When the gray-scale images of conventional IVUS scored by an independent observer were compared, no distinction between adventitia of the native aorta and allograft was possible. Analysis of the average RF backscatter power also showed no significant difference (70.32+/-3.55 versus 70.72+/-3.38 dB). However, the average attenuation of allografts was significantly lower than that of the host aortas (2.64+/-1.38 versus 4.02+/-1.16 dB/mm, P<0.001). Histology demonstrated a marked adventitial inflammatory response in all allografts, with no inflammation observed in the host aortas. CONCLUSIONS: In vivo IVUS tissue characterization can be performed during routine imaging. In this model of transplant vasculopathy, RF attenuation measurements were more sensitive than visual or quantitative gray-scale analysis.


Assuntos
Aorta/transplante , Rejeição de Enxerto/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Colágeno/análise , Macaca fascicularis , Ondas de Rádio , Transplante Homólogo , Ultrassonografia
7.
Circulation ; 104(16): 1917-22, 2001 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-11602494

RESUMO

BACKGROUND: Determination of fractional flow reserve (FFR) has been proposed as a means to assess stent deployment. In this prospective, multicenter trial, we evaluate the use of FFR to optimize stenting by comparing it with standard intravascular ultrasound (IVUS) criteria. METHODS AND RESULTS: Eighty-four stable patients with isolated coronary lesions underwent coronary stent deployment starting at 10 atm and increased serially by 2 atm until the FFR was >/=0.94 or 16 atm was achieved. IVUS was then performed. FFR was measured with a coronary pressure wire with intracoronary adenosine to induce hyperemia. The diagnostic characteristics of an FFR <0.94 to predict suboptimal stent expansion by IVUS, defined in both absolute and relative terms, were calculated. Over a range of IVUS criteria, the highest sensitivity, specificity, and predictive accuracy of FFR were 80%, 30%, and 42%, respectively. Receiver operator characteristic analysis defined an optimal FFR cut point at >/=0.96; at this threshold, the sensitivity, specificity, and predictive accuracy of FFR were 75%, 58%, and 62%, respectively (P=0.03 for comparison of predictive accuracy, P=0.01 for concordance between FFR and IVUS). The negative predictive value was 88%. Significantly better diagnostic performance was achieved in a subgroup that received higher doses (>30 microgram) of intracoronary adenosine during pressure measurements, suggesting that FFR might be overestimated in the other group. CONCLUSIONS: A fractional flow reserve <0.96, measured after stent deployment, predicts a suboptimal result based on validated intravascular ultrasound criteria; however, an FFR >/=0.96 does not reliably predict an optimal stent result. Higher doses of intracoronary adenosine than previously used to measure FFR improve these results.


Assuntos
Angioplastia Coronária com Balão/métodos , Implante de Prótese Vascular/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Ultrassonografia de Intervenção , Adenosina , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Feminino , Humanos , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Stents , Resultado do Tratamento
8.
Circulation ; 102(5): 523-30, 2000 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-10920064

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone. METHODS AND RESULTS: The CRUISE (Can Routine Ultrasound Influence Stent Expansion) study, a multicenter study IVUS substudy of the Stent Anti-thrombotic Regimen Study, was designed to assess the impact of IVUS on stent deployment in the high-pressure era. Nine centers were prospectively assigned to stent deployment with the use of ultrasound guidance and 7 centers to angiographic guidance alone with documentary (blinded) IVUS at the conclusion of the procedure. A total of 525 patients were enrolled with completed quantitative coronary angiography, quantitative coronary ultrasound, and clinical events adjudicated at 9 months for 499 patients. The IVUS-guided group had a larger minimal lumen diameter (2.9+/-0.4 versus 2.7+/-0. 5 mm, P<0.001) by quantitative coronary angiography and a larger minimal stent area (7.78+/-1.72 versus 7.06+/-2.13 mm(2), P<0.001) by quantitative coronary ultrasound. Target vessel revascularization, defined as clinically driven repeat interventional or surgical therapy of the index vessel at 9 month-follow-up, occurred significantly less frequently in the IVUS-guided group (8.5% versus 15.3%, P<0.05; relative reduction of 44%). CONCLUSIONS: These data suggest that ultrasound guidance of stent implantation may result in more effective stent expansion compared with angiographic guidance alone.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Stents , Ultrassonografia de Intervenção , Aspirina , Angiografia Coronária , Doença das Coronárias/mortalidade , Cumarínicos/uso terapêutico , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Ticlopidina/uso terapêutico , Resultado do Tratamento
9.
J Am Coll Cardiol ; 8(5): 1047-58, 1986 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2876020

RESUMO

This study describes the velocity characteristics of left ventricular and aortic outflow in 25 patients with hypertrophic "obstructive" cardiomyopathy. Systematic pulsed and continuous wave Doppler analysis combined with phonocardiography and M-mode echocardiography was used to establish the pattern and timing of outflow in the basal and provoked states. This analysis suggests that 1) the high velocity left ventricular outflow jet can be reliably discriminated from both aortic flow and the jet of mitral regurgitation using Doppler ultrasound; 2) the Doppler velocity contour responds in a characteristic fashion to provocative influences including extrasystole and Valsalva maneuver; 3) the onset of mitral regurgitation occurs well before detectable systolic anterior motion of the mitral valve; 4) left ventricular flow velocities are elevated at the onset of systolic anterior motion of the mitral valve, suggesting a significant contribution of the Venturi effect in displacing the leaflets and chordae; 5) the high velocities of the outflow jets are largely dissipated by the time flow reaches the aortic valve; and 6) late systolic flow in the ascending aorta is nonuniform, with formation of distinct eddies that may contribute to "preclosure" of the aortic valve.


Assuntos
Cardiomiopatia Hipertrófica/fisiopatologia , Nitrito de Amila , Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Ecocardiografia , Humanos , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Contração Miocárdica , Volume Sistólico , Manobra de Valsalva
10.
J Am Coll Cardiol ; 17(6 Suppl B): 39B-45B, 1991 May.
Artigo em Inglês | MEDLINE | ID: mdl-2016481

RESUMO

Intravascular ultrasound is a new method for visualizing the details of vascular pathology, providing high resolution images of plaque and thrombus. This review summarizes the potential applications of ultrasound imaging in the guidance of balloon angioplasty, atherectomy, laser ablation and stenting. Ultrasound differs from angiography and angioscopy in its ability to penetrate below the surface of the vessel lumen, demonstrating specific aspects about the distribution and composition of plaque. Because the different layers of the arterial wall have different acoustic properties, ultrasound catheters are able to define the layers of normal wall in comparison with plaque. Particularly in combination with therapeutic techniques designed to remove or ablate plaque, ultrasound may prove useful in maximizing the amount of plaque treated and minimizing trauma to normal vessel wall components. Combined imaging/therapeutic devices are in the pilot phase of development and show promise for enhancing the safety and efficacy of the catheter devices.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Angioplastia Coronária com Balão , Angioplastia a Laser , Doença da Artéria Coronariana/terapia , Humanos , Stents , Ultrassonografia
11.
J Am Coll Cardiol ; 7(3): 595-602, 1986 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3950239

RESUMO

M-mode echocardiography and Doppler ultrasonography were used to study patterns of atrioventricular (AV) valve motion and flow in five patients with complete heart block, normal ventricular function and an implanted dual chamber pacemaker with programmable PQ intervals. Changes in AV valve motion and flow patterns resulting from steady state changes in PQ interval over the range studied (75 to 250 ms) were similar in all patients. Events reflecting AV valve opening and rapid ventricular filling bore a constant temporal relation to the Q wave and were unaffected by changes in PQ interval. Events reflecting atrial contraction occurred progressively earlier in diastole with lengthening of the PQ interval, until superimposition of atrial contraction on rapid ventricular filling at a PQ interval of 250 ms. The duration of mid-diastolic slow ventricular filling and overall diastole, defined with respect to an open valve, decreased with lengthening of the PQ interval. The onset of AV valve closure (A point) bore a constant temporal relation to the P wave, indicating that atrial systole initiated valve closure. However, completion of AV valve closure occurred progressively earlier with respect to the P wave as the PQ interval was decreased. This suggests an increasing contribution of ventricular systole to completion of AV valve closure with decreasing PQ interval. End-diastolic and end-systolic ventricular and atrial dimensions were independent of the PQ interval.


Assuntos
Eletrocardiografia , Bloqueio Cardíaco/fisiopatologia , Contração Miocárdica , Valva Tricúspide/fisiopatologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Diástole , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Fatores de Tempo
12.
J Am Coll Cardiol ; 8(5): 1059-65, 1986 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3760380

RESUMO

Thirty adult patients with aortic stenosis had Doppler echocardiography within 1 day of cardiac catheterization. Noninvasive measurement of the mean transaortic pressure gradient was calculated by applying the simplified Bernoulli equation to the continuous wave Doppler transaortic velocity recording. Stroke volume was measured noninvasively by multiplying the systolic velocity integral of flow in the left ventricular outflow tract (obtained by pulsed Doppler ultrasonography) by the cross-sectional area of the left ventricular outflow tract (measured by two-dimensional echocardiography). Non-invasive measurement of aortic valve area was calculated by two methods. In method 1, the Gorlin equation was applied using Doppler-derived mean pressure gradient, cardiac output and systolic ejection period. Method 2 used the continuity equation. These noninvasive measurements were compared with invasive measurements using linear regression analysis, and mean pressure gradients correlated well (r = 0.92). Aortic valve area by either noninvasive method also correlated well with cardiac catheterization values (method 1, r = 0.87; method 2, r = 0.88). The sensitivity of Doppler detection of critical aortic stenosis was 0.86, with a specificity of 0.88 and a positive predictive value of 0.86. Cardiac output measured nonsimultaneously showed poor correlation (r = 0.51). Doppler echocardiography can distinguish critical from noncritical aortic stenosis with a high degree of accuracy. Measurement of aortic valve area aids interpretation of Doppler-derived mean pressure gradient data when the gradients are in an intermediate range (30 to 50 mm Hg).


Assuntos
Estenose da Valva Aórtica/patologia , Ecocardiografia , Estenose da Valva Aórtica/fisiopatologia , Pressão Sanguínea , Cateterismo Cardíaco , Débito Cardíaco , Humanos , Modelos Cardiovasculares
13.
J Am Coll Cardiol ; 11(4): 752-6, 1988 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3351141

RESUMO

The continuous wave Doppler ultrasound signal across the left ventricular outflow tract in hypertrophic cardiomyopathy has a characteristic pattern that is in keeping with the dynamic nature of the pressure gradient in this condition. To determine the accuracy and reliability of the peak Doppler flow velocity signal for measuring the peak pressure gradient in this condition, 340 beats were analyzed from five consecutive patients studied with simultaneous continuous wave Doppler ultrasound and dual catheter pressure recordings across the left ventricular outflow tract. Each patient was studied at steady state and during physiologic and pharmacologic manipulations of the pressure gradient. Peak velocity and calculated peak gradient were determined by two independent observers who did not know the catheter measurements. In addition, 18 beats with well defined flow velocity envelopes were digitized for analysis of the magnitude, timing and contour of the instantaneous Doppler ultrasound and catheter gradients throughout systole. Peak catheter gradient in the 340 beats ranged from 12 to 245 mm Hg. The correlations between the Doppler-derived and catheter peak gradients were close (r = 0.96, SEE = 4 mm Hg for Observer 1 and r = 0.97, SEE = 11 mm Hg for Observer 2). Interobserver variability for measurement of peak flow velocity was small (mean +/- SD 0.16 +/- 0.15 m/s). An interobserver difference greater than 0.3 m/s occurred in 25 of the 340 beats analyzed. By retrospective analysis, this was due to contamination of the outflow tract signal by mitral regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Pressão Sanguínea , Cardiomiopatia Hipertrófica/fisiopatologia , Ecocardiografia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução do Fluxo Ventricular Externo/fisiopatologia
14.
J Am Coll Cardiol ; 26(3): 807-14, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7642876

RESUMO

OBJECTIVES: We sought to examine the immediate vasodilator effect of intracoronary estrogen on epicardial and resistance coronary arteries in 19 dogs. BACKGROUND: Although estrogen reportedly dilates coronary arteries in vitro, the site and mechanisms of its action have not been fully defined in vivo. METHODS: Epicardial coronary artery dimensions and coronary flow velocity were assessed using simultaneous intracoronary two-dimensional and Doppler ultrasound. RESULTS: Estrogen (0.1 and 1 mumol/liter) induced a significant increase in coronary cross-sectional area, flow velocity and volumetric blood flow. Estrogen-induced vasodilation was not influenced either by pretreatment with N omega-nitro-L-arginine methyl ester (L-NAME) (100 mumol/liter intracoronary), indomethacin (5 mg/kg body weight intravenously), propranolol (0.75 mg/kg intravenously) or the classic estrogen receptor antagonist ICI 182,780 (10 mumol/liter). Balloon denudation of the endothelium did not attenuate estrogen-induced epicardial vasodilation. Pretreatment with glibenclamide (10 mumol/liter) attenuated estrogen-induced vasodilation only in epicardial arteries, as did verapamil (0.1 mumol/liter). Estrogen had no effect on a phenylephrine dose-response curve in either epicardial coronary arteries or the microcirculation. CONCLUSIONS: Acute estrogen-induced dilation in canine coronary arteries is endothelium independent and is not mediated by the classic intracellular estrogen receptor but through non-genomic mechanisms, presumably at the membrane level, which in epicardial arteries may include effects on adenosine triphosphate-sensitive potassium or calcium channels, or both.


Assuntos
Vasos Coronários/efeitos dos fármacos , Estrogênios/farmacologia , Resistência Vascular/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Vasodilatadores/farmacologia , Análise de Variância , Animais , Cateterismo Periférico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Cães , Relação Dose-Resposta a Droga , Interações Medicamentosas , Feminino , Masculino , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/estatística & dados numéricos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
15.
J Am Coll Cardiol ; 29(2): 283-92, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9014979

RESUMO

OBJECTIVES: We sought to determine the effect of inhomogeneous distribution of beam power produced by Doppler catheters on measurements of mean and peak velocity of coronary blood flow. BACKGROUND: Measurements of mean velocity of coronary blood flow by Doppler catheters have significant systematic errors that have not been completely characterized. We hypothesized that one error is the inhomogeneous distribution of the ultrasonic beam power and that this inhomogeneity makes measurements of mean, but not peak, velocity inaccurate. METHODS: We constructed a scaled-up model of a Doppler catheter to allow for accurate measurement of the distribution of beam power by miniature hydrophones. This catheter was placed in a model of coronary blood flow in which the fluid velocity was accurately measured by an external laser Doppler velocimeter. The laser Doppler measurements of mean velocity were compared with the measurements of mean velocity made by the catheter, using fast Fourier transform analysis, both without and with correction for inhomogeneous beam power distribution. Peak velocity measurements were also compared, as predicted from theory, without the need of correction for inhomogeneous beam power distribution. To investigate the clinical relevance of our results, we conducted studies using a clinical Doppler catheter both in a scaled model of coronary flow and in a series of eight patients. In the model and in each patient, we rotated the catheter without changing the axial position to systematically alter the relation of the beam power distribution to the local fluid dynamics. RESULTS: The measurement of beam power distribution revealed significant inhomogeneity. Comparison of the measured mean frequency shifts without correction for inhomogeneities in the distribution yielded a statistically significant difference. After correction for inhomogeneities, there was no statistically significant difference. Also, there was no significant difference for the peak frequency shifts. Rotation of the clinical catheter in the scaled model and in the patients changed the measured mean velocity (average change 18.8% and 20.6%, respectively), but not the measured peak velocity (average change 5.0% and 4.3%, respectively). CONCLUSIONS: For signal analysis using a fast Fourier transform, the inhomogeneous distribution of power of the ultrasonic beam produced by Doppler catheters makes measurements of mean, but not peak, velocity inaccurate. Measurements of peak velocity may therefore prove superior to measurements of mean velocity in estimating the response to pharmacologic intervention and in estimating stenosis severity.


Assuntos
Cateterismo Cardíaco , Circulação Coronária , Fluxometria por Laser-Doppler , Ultrassom , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Transdutores
16.
J Am Coll Cardiol ; 38(7): 2001-5, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11738307

RESUMO

OBJECTIVES: The purpose of this study was to assess the impact of pre-intervention arterial remodeling on subsequent vessel behavior following balloon angioplasty. BACKGROUND: Positive arterial remodeling before intervention has been shown to have a negative impact on the clinical outcome after nonstented coronary interventional procedures. However, the mechanism of interventions in coronary vessel geometry over time is less well characterized. METHODS: Serial (pre-, post- and follow-up) intravascular ultrasound analysis was performed in 46 native coronary lesions. Positive remodeling (PR) was defined as vessel area (VA) at the target lesion greater than that of average reference segments. Intermediate or negative remodeling (IR/NR) was defined as VA at the target lesion less than or equal to that of average reference segment. Remodeling index was defined as VA at the target lesion site divided by that of average references. RESULTS: Pre-interventional PR and IR/NR were present in 21 (46%) and 25 (54%) of 46 patients, respectively. At follow-up, the change in plaque area was similar between the two groups (1.3 +/- 2.1 vs. 1.2 +/- 2.1 mm(2), p = 0.840). Lesions with PR showed a significantly smaller change in VA than those with IR/NR (-0.2 +/- 2.5 vs. 1.4 +/- 2.3 mm(2), p = 0.03). As a result, late lumen loss was significantly larger in lesions whose pre-intervention configuration exhibited PR (-1.5 +/- 1.8 vs. 0.2 +/- 1.6 mm(2), p = 0.002). CONCLUSIONS: Lesions with PR appear to have less capacity to compensate for further plaque growth after balloon angioplasty and thus show a proportional increase in late lumen loss. This may in part explain the less favorable clinical outcomes of positively remodeled lesions.


Assuntos
Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular/fisiologia , Idoso , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
17.
J Am Coll Cardiol ; 21(5): 1261-8, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8459086

RESUMO

OBJECTIVES: The aim of this study was to determine the differential effects of nitroglycerin, ergonovine and adenosine on the resistance vessels in vivo by using a Doppler-tipped guide wire in combination with an ultrasound imaging catheter. BACKGROUND: Catheter-based two-dimensional intravascular ultrasound yields images of the coronary arteries from which cross-sectional areas can be measured. Intravascular Doppler ultrasound techniques allow measurement of coronary blood flow velocity. The simultaneous use of the two techniques can yield anatomic and physiologic information on conductance and resistance vessels but has not been tried in the coronary arteries. METHODS: In 15 dogs, we studied coronary flow and vascular reactivity in response to pharmacologic agents using two approaches: 1) a 30-MHz, 4.3F imaging catheter placed alongside a 0.018-in. (0.046 cm) Doppler wire in the circumflex or left anterior descending coronary artery (n = 5); 2) the ultrasound imaging catheter introduced directly over a 0.014-in. (0.036 cm) Doppler wire (n = 10). Vasodilator and vasoconstrictor responses were studied by using intracoronary nitroglycerin (50, 100 and 200 micrograms), ergonovine (200 micrograms) and adenosine (6 mg). RESULTS: Nitroglycerin caused a dose-dependent increase in epicardial coronary artery cross-sectional area and, to a lesser extent, in average peak flow velocity, resulting in an increase in volumetric coronary blood flow of 39% and 50% at the doses of 100 and 200 micrograms, respectively. With these doses of nitroglycerin, the decrease in diastolic to systolic velocity ratio and the increased change in cross-sectional area from end-diastole to end-systole suggested an enhanced epicardial coronary artery compliance. With ergonovine, a 12% reduction in epicardial coronary artery cross-sectional area was seen, without a significant change in average peak velocity, resulting in a 15% decrease in volumetric coronary blood flow. Adenosine caused a 270% increase in average peak velocity but no change in epicardial coronary artery cross-sectional area, resulting in a 270% increase in volumetric blood flow. CONCLUSIONS: This study demonstrates that nitroglycerin and ergonovine predominantly influence coronary conductance arteries whereas adenosine mainly dilates coronary resistance vessels. These findings also demonstrate that the combined use of a two-dimensional and a Doppler ultrasound transducer within one catheter assembly can provide information on the differential effects of vasoactive agents on the epicardial and microvascular coronary circulation.


Assuntos
Adenosina/farmacologia , Circulação Coronária/efeitos dos fármacos , Vasos Coronários/efeitos dos fármacos , Ergonovina/farmacologia , Nitroglicerina/farmacologia , Animais , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Complacência (Medida de Distensibilidade)/efeitos dos fármacos , Vasos Coronários/diagnóstico por imagem , Cães , Ecocardiografia , Ecocardiografia Doppler , Microcirculação/efeitos dos fármacos , Resistência Vascular/efeitos dos fármacos
18.
J Am Coll Cardiol ; 23(4): 981-7, 1994 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-8106706

RESUMO

OBJECTIVES: We evaluated a new technique for delineation of the vessel wall surface during intravascular ultrasound imaging using echogenic contrast agents. BACKGROUND: Intravascular ultrasound is used for detection of complex vessel wall structures after catheter-based interventions; however, differentiation between the lumen and these wall structures can be difficult. METHODS: In 12 anesthetized dogs, intracoronary ultrasound was performed during intracoronary bolus injection (3 and 6 ml) of different contrast agents (hand-agitated saline solution, standard iohexol, sonicated iohexol, hand-agitated iohexol, SHU 454, SHU 508). Contrast intensity was quantified by videodensitometry, and contrast homogeneity was assessed qualitatively (grade 0 to 3). RESULTS: Peak contrast intensities for SHU 454 and SHU 508 (mean [+/- SD] 48 +/- 9 and 36 +/- 6 U, respectively) were higher compared with standard, sonicated or agitated iohexol (16 +/- 3, 28 +/- 7 and 20 +/- 3 U, respectively) or with agitated saline solution (17 +/- 4 U); intensities were higher for 6 ml compared with that for 3 ml. Contrast homogeneity was higher for SHU 508 (mean [+/- SD] 3.0 +/- 0) and SHU 454 (2.7 +/- 0.5) compared with the other agents (standard iohexol 1.2 +/- 0.4, sonicated iohexol 2.0 +/- 0.5, agitated iohexol 1.8 +/- 0.6, agitated saline solution 1.0 +/- 0.4). Exact delineation of the vessel wall surface was possible in 100% of SHU 508 and in 88% of SHU 454 injections compared with 13% of agitated iohexol and 8% of sonicated iohexol injections. Accurate surface delineation was never achieved with standard iohexol or agitated saline solution. Shadowing of parts of the vessel wall by contrast material occurred at peak intensity of 75% of SHU 508 and 46% of SHU 454 injections but not with the other agents. No adverse physiologic reactions were noted, except for transient negative inotropic effects after 6 ml of SHU 508. CONCLUSIONS: This preliminary study shows that delineation of the vessel wall boundary using echogenic contrast agents during intravascular ultrasound is safe and feasible. Because of higher contrast intensity and homogeneity, SHU 454 and SHU 508 are superior to other agents.


Assuntos
Meios de Contraste , Vasos Coronários/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Animais , Meios de Contraste/farmacologia , Cães , Hemodinâmica/efeitos dos fármacos , Iohexol/farmacologia , Polissacarídeos/farmacologia , Cloreto de Sódio/farmacologia
19.
J Am Coll Cardiol ; 24(5): 1351-7, 1994 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-7930260

RESUMO

OBJECTIVES: The purpose of this study was to describe our preliminary experience using catheter-based intracardiac echocardiography as an adjunct to biplane fluoroscopy for guiding radiofrequency catheter ablation of atrial arrhythmias in the right side of the heart. BACKGROUND: Catheter ablation requires precise positioning and stable ablation electrode-endocardial contact. This procedure is currently guided by an analysis of intracardiac electrograms and fluoroscopy. However, the use of fluoroscopy does not allow the endocardium and certain anatomic landmarks to be identified and is associated with the hazards of radiation exposure. METHODS: Seventeen symptomatic patients were studied. A 10F 10-MHz intracardiac imaging catheter was used to visualize specific anatomic landmarks in the right atrium for directing the ablation electrode in 15 patients undergoing radiofrequency ablation of 19 arrhythmias and to assist with interatrial septal puncture in 3 patients. RESULTS: Continuous intracardiac imaging was performed for a mean +/- SD of 63.6 +/- 39.2 min and demonstrated distal electrode-endocardial tissue contact in 81 (60%) of 134 radiofrequency applications. Movement of the catheter was demonstrated during 36 (44%), microcavitations during 39 (48%) and thrombus during 15 (19%) of the 81 imaged applications. In 7 of 10 procedures for atrial flutter, successful ablation was directed at anatomic corridors in the right atrium visualized with intracardiac echocardiography. During ablation of atrial tachycardia, imaging identified abnormal atrial anatomy related to previous surgery and guided successful ablation of a reentrant tachycardia circulating around these anatomic obstacles. In two procedures for slow pathway modification of atrioventricular node reentrant tachycardia, intracardiac echocardiography confirmed catheter stability at the tricuspid annulus anterior to the coronary sinus. CONCLUSIONS: During catheter ablation, intracardiac echocardiography augments fluoroscopy by visualizing anatomic landmarks, ensuring stable endocardial contact and assisting in transseptal puncture. Ablation of typical atrial flutter can be successfully directed at anatomic corridors identified using intracardiac imaging.


Assuntos
Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter , Ecocardiografia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia/diagnóstico por imagem , Taquicardia/cirurgia , Ecocardiografia/instrumentação , Feminino , Fluoroscopia , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia de Intervenção/instrumentação
20.
J Am Coll Cardiol ; 16(1): 145-54, 1990 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2193046

RESUMO

Intravascular ultrasound imaging is a new method in which high resolution images of the arterial wall are obtained with use of a catheter placed within an artery. An in vitro Plexiglas well model was used to validate measurements of the luminal area, and an excellent correlation was obtained. One hundred thirty segments of fresh peripheral arteries underwent ultrasound imaging and the findings were compared with the corresponding histopathologic sections. Luminal areas determined with ultrasound imaging correlated well with those calculated from microscopic slides (r = 0.98). Three patterns were identified on the ultrasound images: 1) distinct interface between media and adventitia, 2) indistinct interface between media and adventitia but different echo density layers, and 3) diffuse homogeneous appearance. The types of patterns depended on the relative composition of the media and adventitia. Calcification of intimal plaque obscured underlying structures. Atherosclerotic plaque was readily visualized but could not always be differentiated from the underlying media.


Assuntos
Artérias/patologia , Arteriosclerose/patologia , Ultrassonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcinose/patologia , Colágeno/análise , Elasticidade , Elastina/análise , Humanos , Pessoa de Meia-Idade , Modelos Estruturais , Músculo Liso Vascular/patologia , Necrose , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA