Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cerebrovasc Dis ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38310866

RESUMO

INTRODUCTION: While patients who experience improved cognition following carotid endarterectomy (CEA) typically demonstrate restored brain perfusion after the procedure, it is worth noting that less than 50% of patients in whom postoperative cerebral blood flow (CBF) restoration is achieved actually show improved cognition after postoperatively. This suggests that factors beyond the mere restoration of CBF may play a role in postoperative cognitive improvement. Increased iron deposition in the cerebral cortex may cause neural damage, and quantitative susceptibility mapping (QSM) obtained using magnetic resonance imaging (MRI) quantifies magnetic susceptibility in the cerebral cortex, allowing for the assessment of iron deposition in vivo. The purpose of the present study was to determine whether preoperative cortical magnetic susceptibility as well as postoperative changes in CBF are associated with cognitive improvement after CEA. METHODS: Brain MRI with a three-dimensional gradient echo sequence was preoperatively performed in 53 patients undergoing CEA for ipsilateral internal carotid artery stenosis (≥70%), and QSM with brain surface correction and vein removal was obtained. Cortical magnetic susceptibility was measured in the cerebral hemisphere ipsilateral to surgery on QSM. Preoperatively and at two months after the surgery, brain perfusion single-photon emission computed tomography (SPECT) and neuropsychological assessments were conducted. Using these collected data, we evaluated alterations in CBF within the affected hemisphere and assessed cognitive improvements following the operation. RESULTS: A logistic regression analysis showed that a postoperative greater increase in CBF (95% confidence interval [CI], 1.06-1.90; p = 0.0186) and preoperative lower cortical magnetic susceptibility (95% CI, 0.03-0.74; p = 0.0201) were significantly associated with postoperatively improved cognition. Although sensitivity, specificity, and positive- and negative-predictive values with the cutoff value lying closest to the upper left corner of a receiver operating characteristic curve for the prediction of postoperatively improved cognition did not differ between postoperative changes in CBF and preoperative cortical magnetic susceptibility, the specificity and the positive-predictive value were significantly greater for the combination of postoperative changes in CBF and preoperative cortical magnetic susceptibility (specificity, 95% CI, 93-100%; positive-predictive value 95% CI, 68-100%) than for the former parameter alone (specificity, 95% CI, 63-88%; positive-predictive value 95% CI, 20-64%). CONCLUSION: Preoperative cortical magnetic susceptibility as well as postoperative changes in CBF are associated with cognitive improvement after CEA.

2.
BMC Med Imaging ; 23(1): 171, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37904089

RESUMO

A super-resolution deep learning reconstruction (SR-DLR) algorithm trained using data acquired on the ultrahigh spatial resolution computed tomography (UHRCT) has the potential to provide better image quality of coronary arteries on the whole-heart, single-rotation cardiac coverage on a 320-detector row CT scanner. However, the advantages of SR-DLR at coronary computed tomography angiography (CCTA) have not been fully investigated. The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between SR-DLR and model-based iterative reconstruction (MBIR). We prospectively enrolled 70 patients (median age, 69 years; interquartile range [IQR], 59-75 years; 50 men) who underwent CCTA using a 320-detector row CT scanner between January and August 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the twenty stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.3-24.9 HU vs. 27.4 HU; IQR, 24.2-31.2 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 11.8-21.8 vs. 13.7; IQR, 9.9-18.4, p = 0.01) and CNR (median 24.4; IQR, 15.5-30.2 vs. 19.2; IQR, 14.1-23.2, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.68 mm; IQR, 0.61-0.78 mm vs. 0.81 mm; IQR, 0.72-0.96 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.84 mm; IQR, 1.65-2.26 mm vs. 1.52 mm; IQR, 1.28-2.25 mm, p < 0.01) on SR-DLR than on MBIR. Although further large-scale studies using invasive coronary angiography as the reference standard, comparative studies with UHRCT, and studies in more challenging population for CCTA are needed, this study's initial experience with SR-DLR would improve the utility of CCTA in daily clinical practice due to the better image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Masculino , Humanos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Stents , Átrios do Coração , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação
3.
Int Heart J ; 64(5): 839-846, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37704411

RESUMO

The best cardiac phases in retrospective ECG-gated CT for detecting an intimal tear (IT) in aortic dissection (AD) and an ulcer-like projection (ULP) in an intramural hematoma (IMH) have not been established. This study aimed to compare the detection accuracy of diastolic-phase and systolic-phase ECG-gated CT for IT in AD and ULP in IMH, with subsequent surgical or angiographical confirmation as the reference standard.In total, 81 patients (67.6 ± 11.8 years; 41 men) who underwent emergency ECG-gated CT and subsequent open surgery or thoracic endovascular aortic repair for AD (n = 52) or IMH (n = 29) were included. The accuracies of detecting IT and ULP were compared among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of retrospective ECG-gated CT; surgical or angiographical findings were used as the reference standard. The detection accuracy for IT and ULP using only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of ECG-gated CT was 93% [95% CI: 87-97], 94% [95% CI: 88-97], and 95% [95% CI: 90-97], respectively. There were no significant differences in detection accuracy among the 3 acquisition methods (P = 0.55). Similarly, there were no significant differences in the accuracy of detecting IT in AD (P = 0.55) and ULP in IMH (P > 0.99) among only diastolic-phase, only systolic-phase, and both diastolic- and systolic-phase ECG-gated CT.Retrospective ECG-gated CT for detecting IT in AD and ULP in IMH yields highly accurate findings. There were no significant differences seen among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase ECG-gated CT.


Assuntos
Síndrome Aórtica Aguda , Doenças da Aorta , Dissecção Aórtica , Masculino , Humanos , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Estudos Retrospectivos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Tomografia Computadorizada por Raios X/métodos , Eletrocardiografia , Hematoma/cirurgia
4.
Pol J Radiol ; 88: e251-e255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37346423

RESUMO

Purpose: To correlate peripheral enhancement on contrast-enhanced computed tomography (CE-CT) in patients with post-chemotherapy colorectal liver metastases (CRLM) with the corresponding pathological findings. Material and methods: Forty-four patients with CRLM who underwent hepatic resection after preoperative chemotherapy between 2008 and 2013 were included. Two radiologists blinded to the histopathology findings performed a consensus categorization of the marginal contrast effects of CRLM on CE-CT as follows: Group 1, smooth margin without enhancement; Group 2, smooth margin with an enhanced rim; and Group 3, fuzzy margin with/without an enhanced rim. The Kruskal-Wallis test was used to compare the imaging findings with the histological findings. Results: The percentage of infarct-like necrosis was significantly higher in those with CRLM with smooth margins than in those with CRLM with fuzzy margins (p < 0.001, r = 0.62). The percentage of viable cells was lowest in CRLM with smooth margins without enhancement (p < 0.001, r = 0.60). Conclusions: Our findings suggest that the type of necrosis is related to the nature of the margins, and the presence of residual cells is related to peripheral enhancement.

5.
Int Heart J ; 63(2): 319-326, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35185086

RESUMO

Bicuspid aortic valve (BAV) patients with aortic stenosis (AS) are known to develop dilatation of the ascending aorta at a younger age, but the morphology of the aorta in these patients is yet to be investigated. Thus, in this study, we aim to evaluate the aortic morphology of BAV patients with severe AS using thin-slice electrocardiogram (ECG) -gated computed tomography (CT) and identify the possible contributing effect of age.In this retrospective study, 122 BAV and 154 tricuspid aortic valve (TAV) patients who received aortic valve replacement for severe AS were assessed by thin-slice ECG-gated CT and three-dimensional reconstruction. The morphology of the ascending aorta was also evaluated among BAV patients aged < 70 (n = 72) and ≥ 70 (n = 50) years old. As per our findings, BAV patients with severe AS had significantly greater diameter (P < 0.01), elongation (P < 0.01), and tortuosity (P = 0.03) of the ascending aorta; minimum aortic arch angle (P < 0.01); and significantly lower calcified plaque (P < 0.01) compared with those of TAV patients even after adjusting for background. Multiple regression analysis showed that standardized partial regression coefficients (ß) of dilatation (0.5) and elongation (0.35) were higher among other measurements of aortic morphology for BAV patients. BAV patients with severe AS aged ≥ 70 years had significantly greater diameter (42.0 [37.2-46.1] mm versus 40.4 [35.2-44.2] mm, P = 0.049) and elongation (133.8 [123.5-147.3] mm versus 127.0 [111.0-140.0] mm, P = 0.01) of the ascending aorta than those aged < 70 years.BAV patients with severe AS were determined to have greater dilatation and elongation of the ascending aorta. Moreover, BAV patients older than 70 years had greater diameter and elongation of the ascending aorta.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Idoso , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem , Eletrocardiografia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
Radiology ; 294(1): 61-73, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31746688

RESUMO

Background CT allows evaluation of atherosclerosis, coronary stenosis, and myocardial ischemia. Data on the characterization of ischemia and no obstructive stenosis (INOCA) at CT remain limited. Purpose This was an observational study to describe the prevalence of INOCA defined at coronary CT angiography with CT perfusion imaging and associated clinical and atherosclerotic characteristics. The analysis was also performed for the combination of invasive coronary angiography (ICA) and SPECT as a secondary aim. Materials and Methods The prospective CORE320 study (ClinicalTrials.gov: NCT00934037) enrolled participants between November 2009 and July 2011 who were symptomatic and referred for clinically indicated ICA. Participants underwent CT angiography, rest-adenosine stress CT perfusion, and rest-stress SPECT prior to ICA. For this ancillary study, the following three phenotypes were considered, using either CT angiography/CT perfusion or ICA/SPECT data: (a) participants with obstructive (≥50%) stenosis, (b) participants with no obstructive stenosis but ischemia (ie, INOCA) on the basis of abnormal perfusion imaging results, and (c) participants with no obstructive stenosis and normal perfusion imaging results. Clinical characteristics and CT angiography atherosclerotic plaque measures were compared by using the Pearson χ2 or Wilcoxon rank-sum test. Results A total of 381 participants (mean age, 62 years [interquartile range, 56-68 years]; 129 [34%] women) were evaluated. A total of 31 (27%) of 115 participants without obstructive (≥50%) stenosis at CT angiography had abnormal CT perfusion findings. The corresponding value for ICA/SPECT was 45 (30%) of 151. The prevalence of INOCA was 31 (8%) of 381 (95% confidence interval [CI]: 5%, 11%) with CT angiography/CT perfusion and 45 (12%) of 381 (95% CI: 9%, 15%) with ICA/SPECT. Participants with CT-defined INOCA had greater total atheroma volume (118 vs 60 mm3, P = .008), more positive remodeling (13% vs 1%, P = .006), and greater low-attenuation atheroma volume (20 vs 10 mm3, P = .007) than participants with no obstructive stenosis and no ischemia. Comparisons for ICA/SPECT showed similar trends. Conclusion In CORE320, ischemia and no obstructive stenosis (INOCA) prevalence was 8% and 12% at CT angiography/CT perfusion and invasive coronary angiography/SPECT, respectively. Participants with INOCA had greater atherosclerotic burden and more adverse plaque features at CT compared with those with no obstructive stenosis and no ischemia. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by François in this issue.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Circ J ; 84(4): 601-608, 2020 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-32074543

RESUMO

BACKGROUND: Although coronary computed tomography angiography (CTA) is frequently used for identifying coronary artery disease, no studies have investigated the radiation dose in detail in Japan. The aim of this study was to estimate the radiation dose of coronary CTA in Japanese clinical practice and to identify the independent predictors associated with radiation dose.Methods and Results:A multicenter, retrospective, observational study (54 institutions) was conducted for estimating the radiation dose of coronary CTA in 2,469 patients between January and December 2013. Independent predictors associated with radiation dose were investigated on linear regression analysis. Median dose-length product (DLP) was 809.0 mGy·cm (IQR, 350.0-1,368.8 mGy·cm), corresponding to an estimated radiation dose of 11 mSv. The DLP per site significantly differed between institutions (median DLP per site, 92-2,131 mGy·cm; P<0.05). Independent predictors associated with radiation dose on multivariable linear regression were body weight, heart rate, non-stable sinus rhythm, scan length, tube voltage setting, electrocardiogram (ECG)-gated scanning protocol, and the image reconstruction technique (P<0.05 each). CONCLUSIONS: The coronary CTA radiation dose was relatively high in 2013, and it varied significantly between institutions. Effective strategies for radiation dose reduction were low tube voltage ≤100 kVp, retrospective ECG-gated scanning with dose modulation technique, prospective ECG-gated scanning, and the iterative reconstruction technique.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Doses de Radiação , Exposição à Radiação , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia Coronária/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/efeitos adversos , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Sistema de Registros , Estudos Retrospectivos
8.
J Stroke Cerebrovasc Dis ; 29(9): 105081, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32807478

RESUMO

BACKGROUND: Cerebrovascular reactivity (CVR) to acetazolamide (ACZ) on single-photon emission computed tomography (SPECT) can be used to assess the severity of chronic cerebral ischemia; however, this is an invasive method. We examined whether whole-brain magnetic resonance angiography (MRA) at 7T could non-invasively detect impaired CVR in patients with chronic cerebral ischemia by demonstrating the leptomeningeal collaterals (LMCs). METHODS: Fifty-seven patients with symptomatic unilateral cervical stenosis underwent whole-brain time-of-flight MRA at 7T and cerebral perfusion SPECT before/after the ACZ challenge. MRA images were visually assessed based on 6-point grading systems to evaluate the development of LMCs toward the middle cerebral artery (MCA) and antegrade flow of MCA. CVR of the affected side was calculated from the SPECT data. Subsequently, we compared the LMC grades on MRA with CVR on SPECT. RESULTS: CVR was significantly lower in grades ≥ 2 of LMCs than in grades 0-1 (P < 0.05) when applying LMCs from the anterior cerebral artery (ACA) and/or posterior cerebral artery (PCA). These differences were more evident than those in the grading of the antegrade MCA flow. The LMC grades from ACA/PCA readily detected reduced CVR (< 18.4%) with a sensitivity/specificity of 0.79/0.82. CONCLUSION: The development of LMCs on whole-brain MRA at 7T can non-invasively detect reduced CVR with a high sensitivity/specificity in patients with unilateral cervical stenosis.


Assuntos
Angiografia Cerebral/métodos , Circulação Cerebrovascular , Circulação Colateral , Angiografia por Ressonância Magnética , Meninges/irrigação sanguínea , Artéria Cerebral Média/diagnóstico por imagem , Insuficiência Vertebrobasilar/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/fisiopatologia , Imagem de Perfusão , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único , Insuficiência Vertebrobasilar/fisiopatologia
9.
Int Heart J ; 61(5): 961-969, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32921672

RESUMO

Left ventricular (LV) remodeling with aortic stenosis (AS) appears to differ according to sex, but reverse remodeling after transcatheter aortic valve implantation (TAVI) has not been elucidated in a Japanese population. This study aims to determine whether any sex-related differences in LV or reverse remodeling after TAVI exist in the context of severe AS.Of 208 patients who received TAVI for severe AS in our institution, 100 (men, 42; mean age, 83.0 ± 4.9 years) underwent transthoracic echocardiography before and 3 months after TAVI. Despite similar valvular gradients, women with severe AS had lower indexed LV mass (LVMi) than did men (152.3 ± 35.4 versus 173.2 ± 44.6 g/m2, P = 0.005), with smaller indexed LV end-diastolic (LVEDVi) (50.2 ± 13.3 versus 61.4 ± 20.7 mL/m2, P = 0.001) and end-systolic (LVESVi; 17.9 ± 8.7 versus 24.3 ± 13.8 mL/m2, P = 0.006) volumes. After TAVI, women (-6.0% ± 14.4%) had higher reduction in the rate of change of relative wall thickness (RWT) than did men (4.4% ± 19.0%, P = 0.003). Men (-8.9% ± 3.9%) had higher reduction in the rate of change of LVEDVi than did women (1.5% ± 3.3%, P = 0.045). Incidence of LV reverse remodeling defined as a reduction in LVESV of >15% was significantly higher in men (50%) than in women (26%, P = 0.013).In addition to sex differences in the pattern of LV remodeling with AS, reverse LV remodeling after TAVI also differed between sexes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Remodelação Ventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Japão , Masculino , Índice de Gravidade de Doença , Fatores Sexuais , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
11.
J Stroke Cerebrovasc Dis ; 28(11): 104339, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31451338

RESUMO

BACKGROUND: Infarcts in the lateral striate artery (LSA) territory can be caused by several pathological changes, including lipohyalinosis and microatheroma. However, fluid dynamic effects on these changes remain unknown. Thus, we investigated whether the fluid dynamic metrics of the LSAs were altered in patients with acute ischemic stroke using computational fluid dynamics (CFD) analysis. METHODS: Fifty-one patients with acute ischemic stroke confined in the basal ganglia and/or corona radiata underwent high-resolution magnetic resonance angiography (HR-MRA) at 7T. We performed CFD analyses to obtain indices including the wall shear stress (WSS), WSS gradient (WSSG), and flow velocity (FV) and compared these values between the ipsilesional and contralesional sides in the patients with infarcts in the LSA or non-LSA territories. RESULTS: In patients with LSA-territory infarcts, the WSS, WSSG, and FV values were significantly lower in the ipsilesional LSAs than in the contralesional LSAs (P = .01-.03), while these values in the proximal middle cerebral arteries showed no significant lateralities. In contrast, in patients with non-LSA-territory infarcts, there were no significant lateralities in the metrics between the ipsilesional and contralesional sides. CONCLUSIONS: The CFD analyses using HR-MRA revealed significantly low WSS and WSSG values of the ipsilesional LSAs compared with that of the contralesional side in patients with LSA-territory infarcts, suggesting that fluid dynamic factors of LSAs can be one of the risk factors for LSA-territory infarctions.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Angiografia Cerebral/métodos , Artérias Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular , Angiografia por Ressonância Magnética , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Acidente Vascular Cerebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Isquemia Encefálica/fisiopatologia , Artérias Cerebrais/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Estresse Mecânico , Acidente Vascular Cerebral/fisiopatologia
12.
J Magn Reson Imaging ; 47(5): 1373-1379, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28861934

RESUMO

BACKGROUND: Few studies have been reported for T2 -weighted indirect 17 O imaging. PURPOSE/HYPOTHESIS: To evaluate the feasibility of steady-state sequences for indirect 17 O brain imaging. STUDY TYPE: Signal simulation, phantom measurements, and prospective animal experiments were performed in accordance with the institutional guidelines for animal experiments. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: Signal simulations of balanced steady-state free precession (bSSFP) were performed for concentrations of 17 O ranging from 0.037-1.600%. Phantom measurements with concentrations of 17 O water ranging from 0.037-1.566% were also conducted. Six healthy beagle dogs were scanned with intravenous administration of 20% 17 O-labeled water (1 mL/kg). FIELD STRENGTH/SEQUENCE: Dynamic 3D-bSSFP scans were performed at 3T MRI. 17 O-labeled water was injected 60 seconds after the scan start, and the total scan duration was 5 minutes. ASSESSMENT: Based on the result of signal simulation and phantom measurement, signal changes in the beagle dogs were measured and converted into 17 O concentrations. STATISTICAL TESTS: The 17 O concentrations were averaged for every 15 seconds, and compared to the baseline (30-45 sec) with Dunnett's multiple comparison tests. RESULTS: Signal simulation revealed that the relationships between 17 O concentration and the natural logarithm of relative signals were linear. The intraclass correlation coefficient between relative signals in phantom measurement and signal simulations was 0.974. In the animal experiments, significant increases in 17 O concentration (P < 0.05) were observed 60 seconds after the injection of 17 O. At the end of scanning, mean respective 17 O concentrations of 0.084 ± 0.026%, 0.117 ± 0.038, 0.082 ± 0.037%, and 0.049 ± 0.004% were noted for the cerebral cortex, cerebellar cortex, cerebral white matter, and ventricle. DATA CONCLUSION: Dynamic steady-state sequences were feasible for indirect 17 O imaging, and absolute quantification was possible. This method can be applied for the measurement of permeability and blood flow in the brain, and for kinetic analysis of cerebrospinal fluid. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1373-1379.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Isótopos de Oxigênio , Animais , Mapeamento Encefálico , Simulação por Computador , Cães , Imageamento Tridimensional/métodos , Cinética , Masculino , Oxigênio , Imagens de Fantasmas , Prótons , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
13.
J Magn Reson Imaging ; 48(1): 94-101, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29205623

RESUMO

BACKGROUND: Respiration-induced phase shift affects B0 /B1+ mapping repeatability in parallel transmission (pTx) calibration for 7T brain MRI, but is improved by breath-holding (BH). However, BH cannot be applied during long scans. PURPOSE: To examine whether interleaved acquisition during calibration scanning could improve pTx repeatability and image homogeneity. STUDY TYPE: Prospective. SUBJECTS: Nine healthy subjects. FIELD STRENGTH/SEQUENCE: 7T MRI with a two-channel RF transmission system was used. ASSESSMENT: Calibration scanning for B0 /B1+ mapping was performed under sequential acquisition/free-breathing (Seq-FB), Seq-BH, and interleaved acquisition/FB (Int-FB) conditions. The B0 map was calculated with two echo times, and the B1+ map was obtained using the Bloch-Siegert method. Actual flip-angle imaging (AFI) and gradient echo (GRE) imaging were performed using pTx and quadrature-Tx (qTx). All scans were acquired in five sessions. Repeatability was evaluated using intersession standard deviation (SD) or coefficient of variance (CV), and in-plane homogeneity was evaluated using in-plane CV. STATISTICAL TESTS: A paired t-test with Bonferroni correction for multiple comparisons was used. RESULTS: The intersession CV/SDs for the B0 /B1+ maps were significantly smaller in Int-FB than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The intersession CVs for the AFI and GRE images were also significantly smaller in Int-FB, Seq-BH, and qTx than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The in-plane CVs for the AFI and GRE images in Seq-FB, Int-FB, and Seq-BH were significantly smaller than in qTx (Bonferroni-corrected P < 0.01 for all). DATA CONCLUSION: Using interleaved acquisition during calibration scans of pTx for 7T brain MRI improved the repeatability of B0 /B1+ mapping, AFI, and GRE images, without BH. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Mapeamento Encefálico/métodos , Calibragem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Campos Magnéticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
15.
Neuroradiology ; 60(1): 109-115, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29080918

RESUMO

PURPOSE: Preoperative identification of the artery of Adamkiewicz can help prevent postoperative spinal cord injury following thoracic and thoracoabdominal aortic repair. Several studies have demonstrated the feasibility of evaluating the artery of Adamkiewicz using multi-detector row computed tomography (CT), but precise visualization remains a challenge. The present study was conducted to evaluate the usefulness of ultra-high-resolution CT for visualizing the artery of Adamkiewicz with a slice thickness of 0.25 versus 0.5 mm in patients with aortic aneurysms. METHODS: Our institutional review board approved this study. Twenty-four patients with thoracic and thoracoabdominal aneurysms were scanned with beam collimation of 0.25 mm × 128. Images were reconstructed with slice thicknesses of 0.25 and 0.5 mm. The signal-to-noise ratio (SNR) of the aorta and contrast-to-noise ratio (CNR) between the anterior spinal artery and spinal cord were measured. Two independent observers evaluated visualization of the artery of Adamkiewicz and its continuity between the anterior spinal artery and the aorta using a four-point scale. RESULTS: No significant differences in the SNR of the aorta or CNR of the anterior spinal artery were observed between 0.25- and 0.5-mm slices. The average visualization score was significantly higher for 0.25-mm slices (3.58 ± 0.78) than for 0.5-mm slices (3.13 ± 0.99) (p = 0.01). The percentage of patients with nondiagnostic image quality was significantly lower for 0.25-mm slices (8.3%) than for 0.5-mm slices (33.3%) (p = 0.03). CONCLUSION: In patients with aortic aneurysms, ultra-high-resolution CT with 0.25-mm slices significantly improves visualization of the artery of Adamkiewicz compared to 0.5-mm slices.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Coluna Vertebral/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído
16.
Heart Vessels ; 33(7): 777-785, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29330651

RESUMO

Although paroxysmal atrial fibrillation (PAF) is an important cause of cardioembolic stroke, in contrast to chronic AF patients, the anatomical features of the left atrial appendage (LAA) in PAF patients remain unknown. Here, we investigated differences in LAA structures in patients with PAF and those with normal sinus rhythms (NSR) using 3D-computed tomography (3D-CT), which allows us to visualize complicated LAA structures at high spatial resolution. Study subjects were 30 consecutive PAF and 30 NSR patients with complete enhanced cardiac 3D-CT images available. After reconstruction of 3D LAA images, anatomical parameters of the LAA were measured and compared according to three proposed definitions of the LAA orifice plane determined by the following anatomical landmarks: DEF#1, center of warfarin ridge and centerline of proximal left circumflex artery; DEF#2, slope of warfarin ridge and mitral valve annulus; DEF#3, observers' discretion by progressive rotation using the observers' best estimate without the use of landmarks. The LAA volumes of the PAF groups were significantly greater than the NSR group according to all 3 definitions (DEF#1: 1.43 times, DEF#2: 1.44 times, and DEF#3: 1.36 times greater). The LAA orifice area was significantly larger in PAF than in NSR according to DEF#2, but was similar by DEF#1 and DEF#3. Intra-observer and inter-observer variations for any LAA measurements were very low. In conclusion, 3D-CT-based quantitative assessment of the LAA provides highly reproducible and detailed measurements, which can successfully discriminate differences of LAA volume between patients with NSR and those with PAF, suggesting significantly greater volumes in the latter.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Procedimentos Cirúrgicos Cardíacos/métodos , Frequência Cardíaca/fisiologia , Imageamento Tridimensional , Taquicardia Paroxística/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Apêndice Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Taquicardia Paroxística/fisiopatologia , Taquicardia Paroxística/cirurgia
17.
Int Heart J ; 59(4): 868-872, 2018 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-29794394

RESUMO

A 75-year-old woman with chest discomfort and a continuous murmur was admitted to our hospital. During noninvasive examination, computed tomography angiography showed a coronary artery-pulmonary artery fistula with double giant coronary aneurysms (one was 42 mm× 32 mm× 32 mm, and the other was 25 mm× 20 mm× 17 mm) arising from the proximal part of the left anterior descending (LAD) artery. Stress myocardial scintigraphy showed ischemia at the LAD area. Given her frailty, the heart team, including cardiac surgeons, judged that surgical treatment would be difficult. Thus, endovascular embolization for the abnormal vessels was selected. After coronary angiography, two coronary aneurysms were embolized by 53 coils, and the feeding artery was embolized by two coils and one Amplatzer Vascular Plug 4™. A small pulmonary artery fistula remained after the procedures; thus, additional embolization was performed 3 months after the index procedure. Thereafter, angiography showed no flow into the aneurysms, and her symptoms improved.Endovascular embolization might be an effective treatment to achieve aneurysm occlusion in patients at high risk for surgical treatment. Although the present case had double coronary aneurysms with a large feeder vessel, the combination procedure of coils and vascular plug was able to embolize this abnormal vessel.


Assuntos
Fístula Artério-Arterial , Aneurisma Coronário , Vasos Coronários/diagnóstico por imagem , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Artéria Pulmonar/diagnóstico por imagem , Idoso , Fístula Artério-Arterial/diagnóstico , Fístula Artério-Arterial/fisiopatologia , Fístula Artério-Arterial/terapia , Angiografia por Tomografia Computadorizada/métodos , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/fisiopatologia , Aneurisma Coronário/terapia , Angiografia Coronária/métodos , Feminino , Humanos , Risco Ajustado , Resultado do Tratamento
18.
Stroke ; 48(8): 2136-2141, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28663515

RESUMO

BACKGROUND AND PURPOSE: The oxygen extraction fraction (OEF) is an effective metric to evaluate metabolic reserve in chronic ischemia. However, OEF is considered to be accurately measured only when using positron emission tomography (PET). Thus, we investigated whether OEF maps generated by magnetic resonance quantitative susceptibility mapping (QSM) at 7 Tesla enabled detection of OEF changes when compared with those obtained with PET. METHODS: Forty-one patients with chronic stenosis/occlusion of the unilateral internal carotid artery or middle cerebral artery were examined using 7 Tesla-MRI and PET scanners. QSM images were obtained from 3-dimensional T2*-weighted images, using a multiple dipole-inversion algorithm. OEF maps were generated based on susceptibility differences between venous structures and brain tissues on QSM images. OEF ratios of the ipsilateral middle cerebral artery territory against the contralateral side were calculated on the QSM-OEF and PET-OEF images, using an anatomic template. RESULTS: The OEF ratio in the middle cerebral artery territory showed significant correlations between QSM-OEF and PET-OEF maps (r=0.69; P<0.001), especially in patients with a substantial increase in the PET-OEF ratio of 1.09 (r=0.79; P=0.004), although showing significant systematic biases for the agreements. An increased QSM-OEF ratio of >1.09, as determined by receiver operating characteristic analysis, showed a sensitivity and specificity of 0.82 and 0.86, respectively, for the substantial increase in the PET-OEF ratio. Absolute QSM-OEF values were significantly correlated with PET-OEF values in the patients with increased PET-OEF. CONCLUSIONS: OEF ratios on QSM-OEF images at 7 Tesla showed a good correlation with those on PET-OEF images in patients with unilateral steno-occlusive internal carotid artery/middle cerebral artery lesions, suggesting that noninvasive OEF measurement by MRI can be a substitute for PET.


Assuntos
Angiografia Digital/métodos , Isquemia Encefálica/diagnóstico por imagem , Mapeamento Encefálico/métodos , Angiografia por Ressonância Magnética/métodos , Consumo de Oxigênio/fisiologia , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/metabolismo , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio/metabolismo , Estudos Prospectivos
19.
Radiology ; 284(1): 55-65, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28290782

RESUMO

Purpose To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial perfusion imaging. Materials and Methods This study was approved by all institutional review boards, and written informed consent was obtained. Between November 2009 and July 2011, 381 participants clinically referred for ICA and aged 45-85 years were enrolled in the Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) prospective multicenter diagnostic study. All images were analyzed in blinded independent core laboratories, and a panel of physicians adjudicated all adverse events. MACE was defined as revascularization (>30 days after index ICA), myocardial infarction, or cardiac death; hospitalization for chest pain or congestive heart failure; or arrhythmia. Late MACE was defined similarly, except for patients who underwent revascularization within the first 182 days after ICA, who were excluded. Comparisons of 2-year survival (time to MACE) used standard Kaplan-Meier curves and restricted mean survival times bootstrapped with 2000 replicates. Results An MACE (49 revascularizations, five myocardial infarctions, one cardiac death, nine hospitalizations for chest pain or congestive heart failure, and one arrhythmia) occurred in 51 of 379 patients (13.5%). The 2-year MACE-free rates for combined CT angiography and CT perfusion findings were 94% negative for coronary artery disease (CAD) versus 82% positive for CAD and were similar to combined ICA and single photon emission CT findings (93% negative for CAD vs 77% positive for CAD, P < .001 for both). Event-free rates for CT angiography and CT perfusion versus ICA and single photon emission CT for either positive or negative results were not significantly different for MACE or late MACE (P > .05 for all). The area under the receiver operating characteristic curve (AUC) for combined CT angiography and CT perfusion (AUC = 68; 95% confidence interval [CI]: 62, 75) was similar (P = .36) to that for combined ICA and single photon emission CT (AUC = 71; 95% CI: 65, 79) in the identification of MACE at 2-year follow-up. Conclusion Combined CT angiography and CT perfusion enables similar prediction of 2-year MACE, late MACE, and event-free survival similar to that enabled by ICA and single photon emission CT. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Inquéritos e Questionários , Análise de Sobrevida
20.
Neuroradiology ; 59(8): 759-769, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28689259

RESUMO

PURPOSE: We investigated whether diffusion kurtosis imaging (DKI) and quantitative susceptibility mapping (QSM) could detect pathological changes that occur in Parkinson's disease (PD), multiple system atrophy with predominant parkinsonism (MSA-P) or predominant cerebellar ataxia (MSA-C), and progressive supranuclear palsy syndrome (PSPS) and thus be used for differential diagnosis that is often difficult. METHODS: Seventy patients (41 with PD, 6 with MSA-P, 7 with MSA-C, 16 with PSPS) and 20 healthy controls were examined using a 3.0 T MRI scanner. From DKI and QSM data, we automatically obtained mean kurtosis (MK), fractional anisotropy (FA), and mean diffusivity (MD) values of the midbrain tegmentum (MBT), pontine crossing tract (PCT), and superior/middle cerebellar peduncles (CPs), which were used to calculate diffusion MBT/PCT ratios (dMPRs) and diffusion superior/middle CP ratios (dCPRs), as well as MS (magnetic susceptibility) values of the anterior/posterior putamen (PUa and PUp) and globus pallidus (GP). RESULTS: dMPRs of MK were significantly decreased in PSPS and increased in MSA-C compared with the other groups, while dCPRs of MK showed significant differences only between MSA-C and PD, PSPS, or control. MS values were significantly increased in the PUp of MSA-P and in the PUa and GP of PSPS compared with those in PD. The combined use of MK-dMPR and MS-PUp showed sensitivities of 83-100% and specificities of 81-100% for discriminating among the disease groups, respectively. CONCLUSION: A quantitative assessment using DKI and QSM analyses, particularly MK-dMPR and MS-PUp values, can readily identify patients with parkinsonism.


Assuntos
Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Transtornos Parkinsonianos/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Anisotropia , Estudos de Casos e Controles , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Atrofia de Múltiplos Sistemas/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Paralisia Supranuclear Progressiva/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA