Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38814599

RESUMO

Objective: To assess the usefulness of combining positron emission tomography/computed tomography (PET/CT) with lung cancer autoantibody detection in identifying and managing lung nodules. Methods: The researchers identified 160 patients with pulmonary nodules admitted to their hospital between January 2018 and January 2021. These patients were designated as the experimental group. Additionally, 60 healthy individuals without pulmonary nodules were admitted to the hospital during the same period. The individuals constituted the control group. All study participants underwent digital PET/CT detection and had their lung cancer autoantibody levels determined through enzyme-linked immunosorbent assay. Further testing, such as puncture or surgical pathology, was performed for patients with lung nodules. The aim was to evaluate the significance of combining PET/CT with autoantibody detection in diagnosing and treating lung nodules. Results: The study found that testing multiple autoantibodies together increased sensitivity and accuracy compared to testing individual autoantibodies. Combining PET/CT screening with autoantibody detection improved the diagnostic rate for identifying lung nodules, including benign and suspected malignant ones. Several autoantibodies were significantly higher in the experimental group compared to the control group. Testing for multiple autoantibodies showed higher sensitivity and accuracy than testing for one. Pathological examination confirmed 129 benign nodules and 31 malignant nodules. The median SUVmax values were measured at 0.7 for benign nodules and 4.8 for malignant nodules. The diagnostic efficacy of PET/CT combined with autoantibodies was determined through comparison with pathology testing and was as follows: PET/CT combined with autoantibody detection > PET/CT > autoantibody detection. Conclusion: Combining PET/CT with the detection of autoantibodies enhances the positive diagnostic rate and accuracy of lung nodules in the case of lung cancer. The SUVmax also shows excellent potential as a supplement in diagnosing both benign and malignant lung nodules, providing valuable guidance in determining the pathological types.

2.
Phys Chem Chem Phys ; 25(47): 32317-32322, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-37991811

RESUMO

We report the first use of carbon-doped boron nitride (BCN) for H2S-selective catalytic oxidation. The obtained carbon-doped BN with an ultrathin layer structure exhibits outstanding H2S elimination and high S yield. In particular, BN doped carbon nanosheets display better catalytic performance than traditional catalysts, such as iron- and carbon-based catalysts. The findings of the present work shed a new light on metal-free catalysts for efficient catalytic removal of toxic H2S.

3.
BMC Pulm Med ; 23(1): 511, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38102594

RESUMO

BACKGROUND: Immunogenic cell death (ICD) stimulates adaptive immunity and holds significant promise in cancer therapy. Nevertheless, the influence of ICD-associated long non-coding RNAs (lncRNAs) on the prognosis of patients with lung squamous cell carcinoma (LUSC) remains unexplored. METHODS: We employed data from the The Cancer Genome Atlas (TCGA)database to identify ICD-related lncRNAs associated with the prognosis of LUSC using univariate Cox regression analysis. Subsequently, we utilized the LOSS regression model to construct a predictive risk model for assessing the prognosis of LUSC patients based on ICD-related lncRNAs. Our study randomly allocated187 TCGA patients into a training group and 184 patients for testing the predictive model. Furthermore, we conducted quantitative polymerase chain reaction (qPCR) analysis on 43 tumor tissues from LUSC patients to evaluate lncRNA expression levelsPearson correlation analysis was utilized to analyze the correlation of risk scores with positron emission tomography/computed tomography (PET/CT) parameters among LUSC patients. RESULTS: The findings from the univariate Cox regression revealed 16 ICD-associated lncRNAs linked to LUSC prognosis, with 12 of these lncRNAs integrated into our risk model utilizing the LOSS regression. Survival analysis indicated a markedly higher overall survival time among patients in the low-risk group compared to those in the high-risk group. The area under the Receiver operating characteristic (ROC) curve to differentiate high-risk and low-risk patients was 0.688. Additionally, the overall survival rate was superior in the low-risk group compared to the high-risk group. Correlation analysis demonstrated a positive association between the risk score calculated based on the ICD-lncRNA risk model and the maximum standard uptake value (SUVmax) (r = 0.427, P = 0.0043) as well as metabolic volume (MTV)of PET-CT (r = 0.360, P = 0.0177) in 43 LUSC patients. CONCLUSION: We have successfully developed a risk model founded on ICD-related lncRNAs that proves effective in predicting the overall survival of LUSC patients.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Carcinoma de Células Escamosas , Neoplasias Pulmonares , RNA Longo não Codificante , Humanos , RNA Longo não Codificante/genética , RNA Longo não Codificante/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/genética , Morte Celular Imunogênica , Regulação Neoplásica da Expressão Gênica , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma de Células Escamosas/patologia , Prognóstico , Pulmão/patologia
4.
J Digit Imaging ; 36(5): 2025-2034, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37268841

RESUMO

Ankylosing spondylitis (AS) is a chronic inflammatory disease that causes inflammatory low back pain and may even limit activity. The grading diagnosis of sacroiliitis on imaging plays a central role in diagnosing AS. However, the grading diagnosis of sacroiliitis on computed tomography (CT) images is viewer-dependent and may vary between radiologists and medical institutions. In this study, we aimed to develop a fully automatic method to segment sacroiliac joint (SIJ) and further grading diagnose sacroiliitis associated with AS on CT. We studied 435 CT examinations from patients with AS and control at two hospitals. No-new-UNet (nnU-Net) was used to segment the SIJ, and a 3D convolutional neural network (CNN) was used to grade sacroiliitis with a three-class method, using the grading results of three veteran musculoskeletal radiologists as the ground truth. We defined grades 0-I as class 0, grade II as class 1, and grades III-IV as class 2 according to modified New York criteria. nnU-Net segmentation of SIJ achieved Dice, Jaccard, and relative volume difference (RVD) coefficients of 0.915, 0.851, and 0.040 with the validation set, respectively, and 0.889, 0.812, and 0.098 with the test set, respectively. The areas under the curves (AUCs) of classes 0, 1, and 2 using the 3D CNN were 0.91, 0.80, and 0.96 with the validation set, respectively, and 0.94, 0.82, and 0.93 with the test set, respectively. 3D CNN was superior to the junior and senior radiologists in the grading of class 1 for the validation set and inferior to expert for the test set (P < 0.05). The fully automatic method constructed in this study based on a convolutional neural network could be used for SIJ segmentation and then accurately grading and diagnosis of sacroiliitis associated with AS on CT images, especially for class 0 and class 2. The method for class 1 was less effective but still more accurate than that of the senior radiologist.


Assuntos
Sacroileíte , Espondilite Anquilosante , Humanos , Espondilite Anquilosante/diagnóstico , Sacroileíte/diagnóstico por imagem , Articulação Sacroilíaca/diagnóstico por imagem , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos
5.
Cell Biol Int ; 44(6): 1363-1372, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32125042

RESUMO

Previous studies have demonstrated that interleukins (ILs) are closely associated with doxorubicin (DOX)-induced cardiac injury. IL-5 is an important member of the IL family, and this study was performed to investigate whether IL-5 affects DOX-induced cardiac injury and its underlying mechanisms. The cardiac IL-5 expression was first detected and the results showed that cardiac IL-5 levels were significantly lower in DOX-treated mice, and IL-5 was mainly derived from cardiac macrophage (Mø). In addition, some DOX-treated mice received an injection of anti-IL-5-neutralizing antibody (nAb), and we found that treatment with a mouse anti-IL-5 nAb significantly upregulated the levels of myocardial injury markers, aggravated cardiac dysfunction, increased M1 macrophage (Mø1) and decreased M2 macrophage (Mø2) differentiation, and promoted apoptotic marker expression. Furthermore, the effect of mouse IL-5 nAb on DOX-induced Mø differentiation and its role on mouse cardiomyocyte (MCM) cells apoptosis were detected in vitro, and the results exhibited that mouse IL-5 nAb promoted Mø1 differentiation but inhibited Mø2 differentiation in vitro and alleviated apoptosis in MCM cells. Our results found a mouse anti-IL-5 nAb-aggravated DOX-induced cardiac injury and dysfunction by alleviating the inflammatory response and myocardial cell apoptosis.


Assuntos
Anticorpos Neutralizantes/farmacologia , Cardiopatias/tratamento farmacológico , Inflamação/tratamento farmacológico , Interleucina-5/sangue , Animais , Apoptose/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Doxorrubicina , Cardiopatias/induzido quimicamente , Inflamação/patologia , Macrófagos/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Miócitos Cardíacos/patologia
6.
Chemphyschem ; 19(12): 1448-1455, 2018 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-29539184

RESUMO

CuO/CeO2 is a kind of promising catalysts for the water-gas shift (WGS) reaction. Efforts were put in to improve its performance through modification of CeO2 support. In this study, portions of CeO2 prepared by a co-precipitation method were separately annealed at 300 °C in air, under vacuum and with H2 , and were used as supports for the fabrication of CuO/CeO2 catalysts. The physicochemical properties of the catalysts were characterized by X-ray diffraction, N2 -physisorption, inductively coupled plasma, Raman spectroscopy, CO2 temperature-programmed desorption, and H2 temperature-programmed reduction techniques. The relation between catalytic performances and physicochemical properties of the CuO/CeO2 catalysts were discussed. Among the three catalysts, the one with CuO supported on H2 -reduced CeO2 shows the highest catalytic activity, mainly due to strong CuO-CeO2 synergetic interaction and high concentration of Frenkel-type oxygen vacancies. The superior catalytic activities can also be attributed to the Cu0 crystals of small size and the oxygen vacancies in non-stoichiometric CeO2-x .

7.
Org Biomol Chem ; 16(21): 3881-3884, 2018 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-29745962

RESUMO

An efficient Fe(NO3)3·9H2O promoted ortho-nitration reaction of aniline derivatives has been developed. This reaction may go through a nitrogen dioxide radical (NO2˙) intermediate, which is generated by the thermal decomposition of iron(iii) nitrate. The practicality of the present method using nontoxic and inexpensive iron reagents has been shown by the broad substrate scope and applications.

8.
Chemistry ; 20(10): 2872-8, 2014 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-24497094

RESUMO

Small and homogeneously dispersed Au and Pt nanoparticles (NPs) were prepared on polymeric carbon nitride (CNx )/mesoporous silica (SBA-15) composites, which were synthesized by thermal polycondensation of dicyandiamide-impregnated preformed SBA-15. By changing the condensation temperature, the degree of condensation and the loading of CNx can be controlled to give adjustable particle sizes of the Pt and Au NPs subsequently formed on the composites. In contrast to the pure SBA-15 support, coating of SBA-15 with polymeric CNx resulted in much smaller and better-dispersed metal NPs. Furthermore, under catalytic conditions the CNx coating helps to stabilize the metal NPs. However, metal NPs on CNx /SBA-15 can show very different catalytic behaviors in, for example, the CO oxidation reaction. Whereas the Pt NPs already show full CO conversion at 160 °C, the catalytic activity of Au NPs seems to be inhibited by the CNx support.


Assuntos
Ouro/química , Nanopartículas Metálicas/química , Nanopartículas/química , Nitrilas/química , Platina/química , Polímeros/química , Silicatos/química , Dióxido de Silício/química , Catálise , Oxirredução
9.
Metabolites ; 14(6)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38921468

RESUMO

Tongmai Sini decoction (TSD), the classical prescriptions of traditional Chinese medicine, consisting of three commonly used herbal medicines, has been widely applied for the treatment of myocardial infarction and heart failure. However, the absorbed components and their metabolism in vivo of TSD still remain unknown. In this study, a reliable and effective method using ultra-performance liquid chromatography coupled with hybrid quadrupole-Orbitrap mass spectrometry (UHPLC-Q-Exactive-MS/MS) was employed to identify prototype components and metabolites in vivo (rat plasma and urine). Combined with mass defect filtering (MDF), dynamic background subtraction (DBS), and neutral loss filtering (NLF) data-mining tools, a total of thirty-two major compounds were selected and investigated for their metabolism in vivo. As a result, a total of 82 prototype compounds were identified or tentatively characterized in vivo, including 41 alkaloids, 35 phenolic compounds, 6 saponins. Meanwhile, A total of 65 metabolites (40 alkaloids and 25 phenolic compounds) were tentatively identified. The metabolic reactions were mainly hydrogenation, demethylation, hydroxylation, hydration, methylation, deoxylation, and sulfation. These findings will be beneficial for an in-depth understanding of the pharmacological mechanism and pharmacodynamic substance basis of TSD.

10.
Eur J Radiol ; 172: 111347, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38325189

RESUMO

OBJECTIVES: This study aimed to evaluate the performance of a deep learning radiomics (DLR) model, which integrates multimodal MRI features and clinical information, in diagnosing sacroiliitis related to axial spondyloarthritis (axSpA). MATERIAL & METHODS: A total of 485 patients diagnosed with sacroiliitis related to axSpA (n = 288) or non-sacroiliitis (n = 197) by sacroiliac joint (SIJ) MRI between May 2018 and October 2022 were retrospectively included in this study. The patients were randomly divided into training (n = 388) and testing (n = 97) cohorts. Data were collected using three MRI scanners. We applied a convolutional neural network (CNN) called 3D U-Net for automated SIJ segmentation. Additionally, three CNNs (ResNet50, ResNet101, and DenseNet121) were used to diagnose axSpA-related sacroiliitis using a single modality. The prediction results of all the CNN models across different modalities were integrated using a stacking method based on different algorithms to construct ensemble models, and the optimal ensemble model was used as DLR signature. A combined model incorporating DLR signature with clinical factors was developed using multivariable logistic regression. The performance of the models was evaluated using receiver operating characteristic (ROC) curves, calibration curves, and decision curve analysis (DCA). RESULTS: Automated deep learning-based segmentation and manual delineation showed good correlation. ResNet50, as the optimal basic model, achieved an area under the curve (AUC) and accuracy of 0.839 and 0.804, respectively. The combined model yielded the highest performance in diagnosing axSpA-related sacroiliitis (AUC: 0.910; accuracy: 0.856) and outperformed the best ensemble model (AUC: 0.868; accuracy: 0.825) (all P < 0.05). Moreover, the DCA showed good clinical utility in the combined model. CONCLUSION: We developed a diagnostic model for axSpA-related sacroiliitis by combining the DLR signature with clinical factors, which resulted in excellent diagnostic performance.


Assuntos
Espondiloartrite Axial , Aprendizado Profundo , Sacroileíte , Humanos , Imageamento por Ressonância Magnética/métodos , Radiômica , Estudos Retrospectivos , Articulação Sacroilíaca/diagnóstico por imagem , Sacroileíte/diagnóstico por imagem
11.
Curr Med Imaging ; 19(10): 1178-1185, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36420878

RESUMO

BACKGROUND: Early and accurate diagnosis is vital for avoiding the development of nondisplaced fractures to displaced fractures. Dual-energy CT (Computed Tomography) can detect bone marrow edema (BME), which may help to detect non-displaced fractures. AIM: To evaluate the value of DECT (Dual-Energy Computed Tomography) VNCa (Virtual noncalcium) images for improving diagnostic performance and confidence in acute non-displaced knee fractures. METHODS: 125 patients with clinical suspicion of knee fractures underwent both DECT and MR. Conventional linear-blended CT and VNCa images were obtained from DECT. First, five readers with varying levels of experience evaluated the presence of fractures on conventional linear-blended CT and graded their diagnostic confidence on a scale of 1 to 10. Then BME with VNCa images was evaluated and compared with MR. Finally, the VNCa images combined with conventional linear-blended CT images were used to reassess the presence of fractures and diagnostic confidence. Diagnostic performance and matched pair analyses were performed. RESULTS: 20 non-displaced knee fractures were detected. The consistency test of VNCa images and MR by five radiologists showed Kappa values are 0.76, 0.79, 0.81,0.85,and 0.90,respectively. The diagnostic performance of all readers was improved when using VNCa images combined with conventional linear-blended CT compared with that with conventional linear-blended CT alone. Diagnostic confidence was improved with combined conventional linear-blended CT and VNCa images (median score:8,8,9,9, and 10, respectively) compared with conventional linear-blended CT alone (median score:7,7,8,9, and 9). CONCLUSION: DECT VNCa images could improve the radiologists' diagnostic performance and confidence with varying levels of experience in the detection of non-displaced knee fractures.


Assuntos
Doenças da Medula Óssea , Fraturas Ósseas , Fraturas do Joelho , Humanos , Medula Óssea , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Edema
12.
J Oncol ; 2022: 9942918, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35368889

RESUMO

Objective: To evaluate the efficacy of the PD-1 inhibitor camrelizumab plus chemotherapy in the first-line treatment of advanced non-small-cell lung cancer (NSCLC) and the prognostic differences of patients with different PET/CT features. Methods: Between December 2018 and October 2020, 100 patients with NSCLC assessed for eligibility treated in our institution were recruited and randomly assigned (1 : 1) to receive either the TC regimen chemotherapy (control group) or the TC regimen chemotherapy plus camrelizumab (study group). The primary endpoints were clinical efficacy, progression-free survival (PFS), and overall survival (OS). A decrease of max standard uptake value (SUVmax) of >30% in primary lung cancer was considered as metabolic remission. The prognostic differences of the eligible patients with different PET/CT features were assessed. Survival data were analyzed using the Kaplan-Meier method to obtain the survival rate and calculate the median survival time. Results: The metabolic remission rate and objective remission rate were significantly higher with chemotherapy plus camrelizumab versus chemotherapy alone. The study group had significantly higher CD3+ and CD4+ T-cell ratios and CD4+/CD8+ ratio and significantly lower CD8+ T-cell ratio than the control group after treatment. PFS (10 months versus 4 months) and OS (HR = 37.094, P ≤ 0.001) were better with camrelizumab plus chemotherapy versus stand-alone chemotherapy. The incidence of adverse events (AE) was similar between the two groups. The patients in the study group were stratified into metabolic remission and metabolic nonremission based on PET/CT results. Intersubgroup analysis showed significantly better PFS and OS in the metabolic remission group than in the nonmetabolic remission group. Conclusion: The camrelizumab plus chemotherapy as a first-line treatment option for NSCLC significantly increases the survival benefit. Metabolic status shown by PET/CT correlates with long-term prognosis and demonstrates a great potential for early assessment of efficacy to support the choice of treatment regimens.

13.
Nanoscale ; 13(9): 5026-5032, 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33645618

RESUMO

Catalytic combustion is a promising way to remove trace amounts of CH4 to alleviate serious environmental concerns. However, the reactivity of a catalyst at low temperature is usually limited because of the difficulty to activate the C-H bond of methane. Herein, we design a Pd(PdO)/Co3O4@SiO2 bimetallic oxide core-shell catalyst which shows much higher activity in the methane combustion reaction compared with Pd(PdO)/SiO2 and Co3O4@SiO2 catalysts without a core-shell structure. The T50% and T90% of Pd(PdO)/Co3O4@SiO2 are 357 °C and 445 °C, respectively, which decrease by 67 °C and 55 °C in comparison with those of Pd(PdO)/SiO2. Extensive characterization demonstrates that the bimetallic oxide core-shell structure can effectively enhance the metal interaction between Pd and Co, which can weaken the strength of the Co-O bond in Pd(PdO)/Co3O4@SiO2. The weakening of the Co-O bond could promote the release of more lattice oxygen species to participate in the C-H breaking, resulting in superior catalytic performance in methane combustion at low temperature.

14.
Eur J Radiol ; 133: 109385, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33157370

RESUMO

PURPOSE: The purpose of this study was to evaluate the diagnostic accuracy of different related contrast material (Rel.CM) values in dual-energy computed tomography (DECT) virtual non-calcium (VNCa) images for the detection of bone marrow edema (BME) in knee. METHOD: This prospective study was approved by the institutional research ethics board, and written informed consent was obtained from all participants. Twenty-three patients (24 knees) who underwent dual-energy CT and MRI within three weeks from July 2018 to June 2019 with a definite history of trauma were enrolled. Each knee was divided into 12 regions. First, MR images served as the reference standard, Receiver operating characteristic (ROC) curve was used and diagnostic accuracy of VNCa images corresponding to different Rel.CM values (1.25, 1.35, 1.45, 1.55, 1.65, 1.75) were analyzed, aimed to select an optimal Rel.CM value of VNCa images for detecting BME. Then, CT values of the normal areas and BME areas were measured on the VNCa images corresponding to the optimal Rel.CM value for preliminary quantitative analysis. The rank-sum test was used to compare the differences of CT values between BME areas and normal bone marrow areas on the VNCa images. RESULTS: The 24 knees were divided into 288 areas. MR Imaging showed BME in 121 areas. The areas under the ROC curve with different Rel.CM values (1.25, 1.35, 1.45, 1.55, 1.65, and 1.75) were 0.633, 0.674, 0.882, 0.684, 0.651, and 0.649, respectively. On the VNCa images of Rel.CM = 1.45, the diagnostic accuracy was the highest (up to 89.2 %), the CT values of the BME area and the normal area were -67.9 (1.7∼-100.1) HU and -94.5 (-69.7∼-144.9) HU, respectively, with statistical significance (Z=-9.804, P < 0.05). CONCLUSIONS: The VNCa images with a Rel.CM value of 1.45 is optimal for the detection of BME in knee.


Assuntos
Medula Óssea , Meios de Contraste , Medula Óssea/diagnóstico por imagem , Cálcio , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
15.
Nan Fang Yi Ke Da Xue Xue Bao ; 40(4): 483-490, 2020 Apr 30.
Artigo em Zh | MEDLINE | ID: mdl-32895139

RESUMO

OBJECTIVE: To develop and validate radiomics models based on non-enhanced magnetic resonance (MR) imaging for differentiating chondrosarcoma from enchondroma. METHODS: We retrospectively evaluated a total of 68 patients (including 27 with chondrosarcoma and 41 with enchondroma), who were randomly divided into training group (n=46) and validation group (n=22). Radiomics features were extracted from T1WI and T2WI-FS sequences of the whole tumor by two radiologists independently and selected by Low Variance, Univariate feature selection, and least absolute shrinkage and selection operator (LASSO). Radiomics models were constructed by multivariate logistic regression analysis based on the features from T1WI and T2WI-FS sequences. The receiver-operating characteristics (ROC) curve and intraclass correlation coefficient (ICC) analyses of the radiomics models and conventional MR imaging were performed to determine their diagnostic accuracy. RESULTS: The ICC value for interreader agreement of the radiomics features ranged from 0.779 to 0.923, which indicated good agreement. Ten and 11 features were selected from the T1WI and T2WI-FS sequences to construct radiomics models, respectively. The areas under the curve (AUCs) of T1WI and T2WI-FS models were 0.990 and 0.925 in training group and 0.915 and 0.855 in the validation group, respectively, showing no significant differences between the two sequence-based models (P>0.05). In all the cases, the AUCs of the two radiomics models based on T1WI and T2WI-FS sequences and conventional MR imaging were 0.955, 0.901 and 0.569, respectively, demonstrating a significantly higher diagnostic accuracy of the two sequence-based radiomics models than conventional MR imaging (P<0.01). CONCLUSIONS: The radiomics models based on T1WI and T2WI-FS non-enhanced MR imaging can be used for the differentiation of chondrosarcoma from enchondroma.


Assuntos
Condroma , Condrossarcoma , Humanos , Imageamento por Ressonância Magnética , Curva ROC , Estudos Retrospectivos
16.
J Hazard Mater ; 398: 123233, 2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-32768850

RESUMO

In the present study, catalytically inactive or low-active Ti4+ (d0) or Zn2+ (d10) ions were doped to α-Fe2O3 to tune the geometric and electronic engineering for Fe active center. X-ray absorption near edge structure (XANES) and Powder X-ray diffraction (XRD) analyses coupled with density functional theory (DFT) calculation show that the added of Ti4+ could occupy the interstitial octahedral or tetrahedral sites, resulting in surface Fe2+ species are oxidized to octahedrally coordinated Fe3+. As a result, more oxygen vacancies are generated, which improve the catalytic performance for toluene combustion. On the other hand, Fe2+ was substituted by Zn2+ ion could result in the partial destruction of hematite crystal structure, forming an additional phase of ZnFe2O4, and meanwhile part of Zn2+ ions replace the octahedrally coordinated Fe3+ sites, and therefore significantly decreasing the toluene catalytic performance. Moreover, our studies demonstrate that the combustions of toluene over Fe-based catalysts involve both the MvK and L-H mechanisms.

17.
ACS Appl Mater Interfaces ; 12(26): 29528-29539, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32508095

RESUMO

Multifunctional luminescent materials with aggregation-induced delayed fluorescence (AIDF) are capable of suppressing concentration-caused emission quenching and exciton annihilation when used as organic light-emitting diode (OLED) emitters. In this contribution, three stimuli-responsive AIDF luminogens, pipd-BZ-PXZ, pipd-BZ-PTZ, and pipd-BZ-DMAC, featuring a D-A asymmetric framework based on a fused N-heterocycle diarylketone acceptor (imid-azo[1,2-a]pyridin-2-yl(phenyl)methanone pipd) are designed and synthesized. Interestingly, pipd-BZ-PTZ forms two different kinds of crystals (G-crystal and O-crystal) with distinct intermolecular interactions between pipd moieties. The G-crystal with a looser packing mode presents significant morphology-dependent stimuli-responsive behavior with a shifted emission wavelength of 56 nm. Generated by a strong intramolecular charge transfer effect, pipd-BZ-PXZ and pipd-BZ-PTZ exhibit orange to red emission in solution and neat films. Both nondoped and doped devices are fabricated for comparison. Nondoped devices present moderate performance with external quantum efficiencies and current efficiency that reach 7.04% and 19.86 cd A-1, respectively, and the corresponding efficiency roll off at 1000 cd m-2 is as small as 2.3%, which is among the best records of AIDF-OLEDs with an emission wavelength over 570 nm. Doped devices show better performance with corresponding efficiencies of up to 55.41 cd A-1 and 15.77%.

18.
Inorg Chem ; 48(5): 1819-25, 2009 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-19235945

RESUMO

A network-structured SnO(2)/ZnO heterojunction nanocatalyst with high photocatalytic activity was successfully synthesized through a simple two-step solvothermal method. The as-synthesized samples are characterized by X-ray diffraction, X-ray photoelectron spectroscopy, transmission electron microscopy, scanning electron microscopy, N(2) physical adsorption, and UV-vis spectroscopy. The results show that the SnO(2)/ZnO sample with a molar ratio of Sn/Zn = 1 is a mesoporous composite material composed of SnO(2) and ZnO. The photocatalytic activity of SnO(2)/ZnO heterojunction nanocatalysts for the degradation of methyl orange is much higher than those of solvothermally synthesized SnO(2) and ZnO samples, which can be attributed to the SnO(2)-ZnO heterojunction, the pore structure, and higher Brunauer-Emmett-Teller (BET) surface area of the sample: (1) The SnO(2)-ZnO heterojunction improves the separation of photogenerated electron-hole pairs due to the potential energy differences between SnO(2) and ZnO, thus enhancing the photocatalytic activity. (2) The SnO(2)/ZnO sample might possess more surface reaction sites and adsorb and transport more dye molecules due to the higher BET surface area and many pore channels, also leading to higher photocatalytic activity.


Assuntos
Nanoestruturas/química , Processos Fotoquímicos , Compostos de Estanho/química , Óxido de Zinco/química , Catálise , Espectrofotometria Ultravioleta , Propriedades de Superfície , Difração de Raios X
19.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(12): 3409-11, 2009 Dec.
Artigo em Zh | MEDLINE | ID: mdl-20210182

RESUMO

Palladium in automotive exhaust catalyst was determined by flame atomic absorption spectrometry (FAAS). The analytical conditions and the coexisting elements interference were studied. The catalyst was dissolved by the mixture of H2O2 and HCl. Pd in the solution was directly determined by FAAS method. The linearity of working curve ranges from 0.1 to 15 microg x mL(-1); the detection limit is 0.029 microg x mL(-1); the relative standard deviation (RSD) range is from 0.8% to 2.5%; and the recovery rate range is from 99.6% to 101.2%. It is a simple and convenient method for accurate analysis of Pd in the exhaust catalysts.

20.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(8): 2166-70, 2009 Aug.
Artigo em Zh | MEDLINE | ID: mdl-19839331

RESUMO

In the present paper, ordered mesoporous silica (KIT-6) as support, nanosized TiO2 into KIT-6 was synthesized by titanium tetraisopropoxide hydrolysis. Then silver was loaded by deposition-precipitation method. Ag-TiO2/KIT-6 composite nanosized photocatalyst was firstly synthesized and a series of correlated catalysts were synthesized by the same preparation method. Methyl orange is presently adopted as a representative organic pollutant to evaluate the photocatalytic performance of the as-synthesized catalysts. The order of photocatalytic activity of the as-synthesized samples was found as Ag-TiO2/KIT-6 > Ag/TiO2 > TiO2/KIT-6 > TiO2 > Ag/KIT-6. Detailed characterizations were conducted by techniques including XRD, N2 physical adsorption, XPS, UV-Vis DRS and TEM. It was found that the Ag-TiO2 /KIT-6 sample shows the highest photocatalytic activity, which should be attributed to the Ag-TiO2 heterojunction structure and higher BET surface area of the Ag-TiO2/KIT-6 sample. Ag-TiO2 heterojunction improves the separation of photogenerated electron-hole pairs, thus enhancing the photocatalytic activity; Ag-TiO2/KIT-6 sample possesses high BET surface area, which facilitates adsorption and transportation of dye molecules, also leading to higher photocatalytic activity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA