Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Sensors (Basel) ; 24(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38339659

RESUMO

Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.

2.
Sensors (Basel) ; 21(4)2021 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-33672262

RESUMO

Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.69 × 109 Ω/cm, which is 47% higher compared to the previous batch from 2016. Moreover, its noise performance is 14% lower with a value of (101.65 ± 0.04) e- ENC and the resolution of a monochromatic 60 keV photo peak is significantly improved by 38% to a FWHM of 4.3%. Likely, this is due to improvements in charge collection, lower noise, and more homogeneous effective pixel size. In a previous work, a hole lifetime of 1.4 ns for GaAs:Cr sensors was determined for the sensors of the 2016 sensor batch, explaining the so-called "crater effect" which describes the occurrence of negative signals in the pixels around a pixel with a photon hit due to the missing hole contribution to the overall signal causing an incomplete signal induction. In this publication, the "crater effect" is further elaborated by measuring GaAs:Cr sensors using the sensors from 2017. The hole lifetime of these sensors was 2.5 ns. A focused photon beam was used to illuminate well defined positions along the pixels in order to corroborate the findings from the previous work and to further characterize the consequences of the "crater effect" on the detector operation.

3.
J Synchrotron Radiat ; 26(Pt 4): 1226-1237, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274448

RESUMO

Recent advances in segmented low-gain avalanche detectors (LGADs) make them promising for the position-sensitive detection of low-energy X-ray photons thanks to their internal gain. LGAD microstrip sensors fabricated by Fondazione Bruno Kessler have been investigated using X-rays with both charge-integrating and single-photon-counting readout chips developed at the Paul Scherrer Institut. In this work it is shown that the charge multiplication occurring in the sensor allows the detection of X-rays with improved signal-to-noise ratio in comparison with standard silicon sensors. The application in the tender X-ray energy range is demonstrated by the detection of the sulfur Kα and Kß lines (2.3 and 2.46 keV) in an energy-dispersive fluorescence spectrometer at the Swiss Light Source. Although further improvements in the segmentation and in the quantum efficiency at low energy are still necessary, this work paves the way for the development of single-photon-counting detectors in the soft X-ray energy range.

4.
J Synchrotron Radiat ; 26(Pt 1): 74-82, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30655470

RESUMO

The Adaptive Gain Integrating Pixel Detector (AGIPD) is an X-ray imager, custom designed for the European X-ray Free-Electron Laser (XFEL). It is a fast, low-noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 104 photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.

5.
J Synchrotron Radiat ; 23(Pt 6): 1462-1473, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27787252

RESUMO

MÖNCH is a 25 µm-pitch charge-integrating detector aimed at exploring the limits of current hybrid silicon detector technology. The small pixel size makes it ideal for high-resolution imaging. With an electronic noise of about 110 eV r.m.s., it opens new perspectives for many synchrotron applications where currently the detector is the limiting factor, e.g. inelastic X-ray scattering, Laue diffraction and soft X-ray or high-resolution color imaging. Due to the small pixel pitch, the charge cloud generated by absorbed X-rays is shared between neighboring pixels for most of the photons. Therefore, at low photon fluxes, interpolation algorithms can be applied to determine the absorption position of each photon with a resolution of the order of 1 µm. In this work, the characterization results of one of the MÖNCH prototypes are presented under low-flux conditions. A custom interpolation algorithm is described and applied to the data to obtain high-resolution images. Images obtained in grating interferometry experiments without the use of the absorption grating G2 are shown and discussed. Perspectives for the future developments of the MÖNCH detector are also presented.

6.
J Synchrotron Radiat ; 23(1): 111-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698052

RESUMO

With the increased brilliance of state-of-the-art synchrotron radiation sources and the advent of free-electron lasers (FELs) enabling revolutionary science with EUV to X-ray photons comes an urgent need for suitable photon imaging detectors. Requirements include high frame rates, very large dynamic range, single-photon sensitivity with low probability of false positives and (multi)-megapixels. At DESY, one ongoing development project - in collaboration with RAL/STFC, Elettra Sincrotrone Trieste, Diamond, and Pohang Accelerator Laboratory - is the CMOS-based soft X-ray imager PERCIVAL. PERCIVAL is a monolithic active-pixel sensor back-thinned to access its primary energy range of 250 eV to 1 keV with target efficiencies above 90%. According to preliminary specifications, the roughly 10 cm × 10 cm, 3.5k × 3.7k monolithic sensor will operate at frame rates up to 120 Hz (commensurate with most FELs) and use multiple gains within 27 µm pixels to measure 1 to ∼100000 (500 eV) simultaneously arriving photons. DESY is also leading the development of the AGIPD, a high-speed detector based on hybrid pixel technology intended for use at the European XFEL. This system is being developed in collaboration with PSI, University of Hamburg, and University of Bonn. The AGIPD allows single-pulse imaging at 4.5 MHz frame rate into a 352-frame buffer, with a dynamic range allowing single-photon detection and detection of more than 10000 photons at 12.4 keV in the same image. Modules of 65k pixels each are configured to make up (multi)megapixel cameras. This review describes the AGIPD and the PERCIVAL concepts and systems, including some recent results and a summary of their current status. It also gives a short overview over other FEL-relevant developments where the Photon Science Detector Group at DESY is involved.

7.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 33(3): 426-30, 2016 Jun.
Artigo em Zh | MEDLINE | ID: mdl-29708717

RESUMO

We carried out study on surface electromyogram(sEMG)signal generated from cluster muscles in trunk and lower limbs on condition of human body walking with heavily burdened shoulder to explore functional status and fatigue property of human muscles and to offer an important reference for finding better ways of loading,improving the performance and design of backpack as well as weight-bearing system more suitable for ergonomics.We measured and obtained surface electromyography signals from the primary muscles clusters in neck,shoulder,back and leg of20 test recipients loaded with different burdens on their shoulders.The eigenvalue of mean power frequency(MPF)were processed with SPSS 16.0.It could be concluded that with the increase of loading weights,male are more likely to be fatigued due to dramatic decrease of trapezius' MPF.While for the female test recipients,the cervical extensor muscles' MPF dropped significantly and were more easily fatigued.Moreover,there was a remarkable difference in terms of electromyography signal before and after the weight reaches certain limit(P<0.05).The maximum weight limit loaded on shoulders for man is 12% of the total bodyweight while such limit for woman is just 9%.


Assuntos
Fadiga Muscular , Músculo Esquelético/fisiologia , Ombro/fisiologia , Suporte de Carga , Dorso , Eletromiografia , Feminino , Humanos , Perna (Membro) , Masculino , Pescoço , Caminhada
8.
Adv Mater ; 36(23): e2311157, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38402421

RESUMO

Understanding the magnetic and ferroelectric ordering of magnetoelectric multiferroic materials at the nanoscale necessitates a versatile imaging method with high spatial resolution. Here, soft X-ray ptychography is employed to simultaneously image the ferroelectric and antiferromagnetic domains in an 80 nm thin freestanding film of the room-temperature multiferroic BiFeO3 (BFO). The antiferromagnetic spin cycloid of period 64 nm is resolved by reconstructing the corresponding resonant elastic X-ray scattering in real space and visualized together with mosaic-like ferroelectric domains in a linear dichroic contrast image at the Fe L3 edge. The measurements reveal a near perfect coupling between the antiferromagnetic and ferroelectric ordering by which the propagation direction of the spin cycloid is locked orthogonally to the ferroelectric polarization. In addition, the study evinces both a preference for in-plane propagation of the spin cycloid and changes of the ferroelectric polarization by 71° between multiferroic domains in the epitaxial strain-free, freestanding BFO film. The results provide a direct visualization of the strong magnetoelectric coupling in BFO and of its fine multiferroic domain structure, emphasizing the potential of ptychographic imaging for the study of multiferroics and non-collinear magnetic materials with soft X-rays.

9.
J Synchrotron Radiat ; 19(Pt 3): 340-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22514167

RESUMO

Imaging experiments at the European X-ray Free Electron Laser (XFEL) require silicon pixel sensors with extraordinary performance specifications: doses of up to 1 GGy of 12 keV photons, up to 10(5) 12 keV photons per 200 µm × 200 µm pixel arriving within less than 100 fs, and a time interval between XFEL pulses of 220 ns. To address these challenges, in particular the question of radiation damage, the properties of the SiO(2) layer and of the Si-SiO(2) interface, using MOS (metal-oxide-semiconductor) capacitors manufactured on high-resistivity n-type silicon irradiated to X-ray doses between 10 kGy and 1 GGy, have been studied. Measurements of capacitance/conductance-voltage (C/G-V) at different frequencies, as well as of thermal dielectric relaxation current (TDRC), have been performed. The data can be described by a dose-dependent oxide charge density and three dominant radiation-induced interface states with Gaussian-like energy distributions in the silicon band gap. It is found that the densities of the fixed oxide charges and of the three interface states increase up to dose values of approximately 10 MGy and then saturate or even decrease. The shapes and the frequency dependences of the C/G-V measurements can be quantitatively described by a simple model using the parameters extracted from the TDRC measurements.

10.
Appl Radiat Isot ; 66(10): 1427-30, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18387305

RESUMO

Cross-sections of the (10)B(n, alpha)(7)Li reaction were measured at En=4.0 and 5.0 MeV. A gridded ionization chamber (GIC) was used as charged particle detector. Neutrons were produced through the D(d, n)(3)He reaction with a deuterium gas target. Experiments were performed at the 4.5 MV Van de Graaff accelerator of Peking University. Cross-section data of the (238)U(n, f) reaction were employed as standard. The measured cross-sections of the (10)B(n, alpha)(7)Li reaction at 4.0 and 5.0 MeV are 211+/-17 and 169+/-14 mb, respectively, and they are compared with existing results of measurements and evaluations.


Assuntos
Boro/química , Boro/efeitos da radiação , Lítio/química , Lítio/efeitos da radiação , Radiometria/instrumentação , Doses de Radiação
11.
Appl Radiat Isot ; 68(1): 180-3, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19811925

RESUMO

Measurements of cross sections of the (95)Mo(n, alpha)(92)Zr reaction at E(n)=4.0, 5.0 and 6.0MeV were carried out at the 4.5MV Van de Graaff of Peking University, China. A twin gridded ionization chamber and two large-area (95)Mo samples were adopted. Fast neutrons were produced through the D(d, n)(3)He reaction by using a deuterium gas target. A small (238)U fission chamber was employed for absolute neutron flux determination. Present data are compared with existing evaluations and measurement.

12.
Appl Radiat Isot ; 67(1): 46-9, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18707895

RESUMO

Cross sections of the (147)Sm(n, alpha)(144)Nd reaction were measured at En=5.0 and 6.0MeV. A twin gridded ionization chamber was used as a charged particle detector and two large area (147)Sm(2)O(3) samples placed back to back were employed. Experiments were performed at the 4.5MV Van de Graaff accelerator of Peking University. Neutrons were produced through the D(d, n)(3)He reaction with a deuterium gas target. Absolute neutron flux was determined by a small (238)U fission chamber. Present cross-section data are compared with existing results of evaluations and measurements.


Assuntos
Neodímio/química , Radioisótopos/química , Radiometria/métodos , Samário/química , Deutério , Nêutrons , Óxidos , Urânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA