Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Neurobiol Dis ; 158: 105455, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34358614

RESUMO

Fatal familial insomnia (FFI) is a dominantly inherited prion disease linked to the D178N mutation in the gene encoding the prion protein (PrP). Symptoms, including insomnia, memory loss and motor abnormalities, appear around 50 years of age, leading to death within two years. No treatment is available. A ten-year clinical trial of doxycycline (doxy) is under way in healthy individuals at risk of FFI to test whether presymptomatic doxy prevents or delays the onset of disease. To assess the drug's effect in a tractable disease model, we used Tg(FFI-26) mice, which accumulate aggregated and protease-resistant PrP in their brains and develop a fatal neurological illness highly reminiscent of FFI. Mice were treated daily with 10 mg/kg doxy starting from a presymptomatic stage for twenty weeks. Doxy rescued memory deficits and restored circadian motor rhythmicity in Tg(FFI-26) mice. However, it did not prevent the onset and progression of motor dysfunction, clinical signs and progression to terminal disease. Doxy did not change the amount of aggregated and protease-resistant PrP, but reduced microglial activation in the hippocampus. Presymptomatic doxy treatment rescues cognitive impairment and the motor correlates of sleep dysfunction in Tg(FFI-26) mice but does not prevent fatal disease.


Assuntos
Ritmo Circadiano/efeitos dos fármacos , Doxiciclina/farmacologia , Doxiciclina/uso terapêutico , Insônia Familiar Fatal/tratamento farmacológico , Memória/efeitos dos fármacos , Reconhecimento Psicológico/efeitos dos fármacos , Animais , Encéfalo/patologia , Progressão da Doença , Insônia Familiar Fatal/genética , Insônia Familiar Fatal/patologia , Camundongos , Camundongos Endogâmicos C57BL , Atividade Motora/efeitos dos fármacos , Desempenho Psicomotor/efeitos dos fármacos
2.
Front Neurosci ; 13: 1023, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31611765

RESUMO

Mechanical forces are increasingly recognized as major regulators of several physiological processes at both the molecular and cellular level; therefore, a deep understanding of the sensing of these forces and their conversion into electrical signals are essential for studying the mechanosensitive properties of soft biological tissues. To contribute to this field, we present a dual-purpose device able to mechanically stimulate retinal tissue and to record the spiking activity of retinal ganglion cells (RGCs). This new instrument relies on combining ferrule-top micro-indentation, which provides local measurements of viscoelasticity, with high-density multi-electrode array (HD-MEAs) to simultaneously record the spontaneous activity of the retina. In this paper, we introduce this instrument, describe its technical characteristics, and present a proof-of-concept experiment that shows how RGC spiking activity of explanted mice retinas respond to mechanical micro-stimulations of their photoreceptor layer. The data suggest that, under specific conditions of indentation, the retina perceive the mechanical stimulation as modulation of the visual input, besides the longer time-scale of activation, and the increase in spiking activity is not only localized under the indentation probe, but it propagates across the retinal tissue.

3.
Adv Neurobiol ; 22: 253-273, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31073940

RESUMO

Active high-density electrode arrays realized with complementary metal-oxide-semiconductor (CMOS) technology provide electrophysiological recordings from several thousands of closely spaced microelectrodes. This has drastically advanced the spatiotemporal recording resolution of conventional multielectrode arrays (MEAs). Thus, today's electrophysiology in neuronal cultures can exploit label-free electrical readouts from a large number of single neurons within the same network. This provides advanced capabilities to investigate the properties of self-assembling neuronal networks, to advance studies on neurotoxicity and neurodevelopmental alterations associated with human brain diseases, and to develop cell culture models for testing drug- or cell-based strategies for therapies.Here, after introducing the reader to this neurotechnology, we summarize the results of different recent studies demonstrating the potential of active high-density electrode arrays for experimental applications. We also discuss ongoing and possible future research directions that might allow for moving these platforms forward for screening applications.


Assuntos
Técnicas de Cultura de Células , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Microeletrodos , Neurônios/citologia , Neurônios/fisiologia , Potenciais de Ação , Humanos , Neurônios/patologia
4.
Front Neurosci ; 10: 121, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27065786

RESUMO

The recent availability of human induced pluripotent stem cells (hiPSCs) holds great promise as a novel source of human-derived neurons for cell and tissue therapies as well as for in vitro drug screenings that might replace the use of animal models. However, there is still a considerable lack of knowledge on the functional properties of hiPSC-derived neuronal networks, thus limiting their application. Here, upon optimization of cell culture protocols, we demonstrate that both spontaneous and evoked electrical spiking activities of these networks can be characterized on-chip by taking advantage of the resolution provided by CMOS multielectrode arrays (CMOS-MEAs). These devices feature a large and closely-spaced array of 4096 simultaneously recording electrodes and multi-site on-chip electrical stimulation. Our results show that networks of human-derived neurons can respond to electrical stimulation with a physiological repertoire of spike waveforms after 3 months of cell culture, a period of time during which the network undergoes the expression of developing patterns of spontaneous spiking activity. To achieve this, we have investigated the impact on the network formation and on the emerging network-wide functional properties induced by different biochemical substrates, i.e., poly-dl-ornithine (PDLO), poly-l-ornithine (PLO), and polyethylenimine (PEI), that were used as adhesion promoters for the cell culture. Interestingly, we found that neuronal networks grown on PDLO coated substrates show significantly higher spontaneous firing activity, reliable responses to low-frequency electrical stimuli, and an appropriate level of PSD-95 that may denote a physiological neuronal maturation profile and synapse stabilization. However, our results also suggest that even 3-month culture might not be sufficient for human-derived neuronal network maturation. Taken together, our results highlight the tight relationship existing between substrate coatings and emerging network properties, i.e., spontaneous activity, responsiveness, synapse formation and maturation. Additionally, our results provide a baseline on the functional properties expressed over 3 months of network development for a commercially available line of hiPSC-derived neurons. This is a first step toward the development of functional pre-clinical assays to test pharmaceutical compounds on human-derived neuronal networks with CMOS-MEAs.

5.
Brain Res Bull ; 119(Pt B): 118-26, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26232511

RESUMO

Deciphering neural network function in health and disease requires recording from many active neurons simultaneously. Developing approaches to increase their numbers is a major neurotechnological challenge. Parallel to recent advances in optical Ca(2+) imaging, an emerging approach consists in adopting complementary-metal-oxide-semiconductor (CMOS) technology to realize MultiElectrode Array (MEA) devices. By implementing signal conditioning and multiplexing circuits, these devices allow nowadays to record from several thousands of single neurons at sub-millisecond temporal resolution. At the same time, these recordings generate very large data streams which become challenging to analyze. Here, at first we shortly review the major approaches developed for data management and analysis for conventional, low-resolution MEAs. We highlight how conventional computational tools cannot be easily up-scaled to very large electrode array recordings, and custom bioinformatics tools are an emerging need in this field. We then introduce a novel approach adapted for the acquisition, compression and analysis of extracellular signals acquired simultaneously from 4096 electrodes with CMOS MEAs. Finally, as a case study, we describe how this novel large scale recording platform was used to record and analyze extracellular spikes from the ganglion cell layer in the wholemount retina at pan-retinal scale following patterned light stimulation.


Assuntos
Potenciais de Ação/fisiologia , Encéfalo/fisiologia , Biologia Computacional/métodos , Neuroimagem/métodos , Neurônios/fisiologia , Animais , Biologia Computacional/instrumentação , Biologia Computacional/tendências , Estimulação Elétrica/métodos , Microeletrodos/tendências , Neuroimagem/instrumentação , Neuroimagem/tendências , Semicondutores
6.
Sci Rep ; 4: 5963, 2014 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-25096831

RESUMO

A portable 16-channels microcontroller-based wireless system for a bi-directional interaction with the central nervous system is presented in this work. The device is designed to be used with freely behaving small laboratory animals and allows recording of spontaneous and evoked neural activity wirelessly transmitted and stored on a personal computer. Biphasic current stimuli with programmable duration, frequency and amplitude may be triggered in real-time on the basis of the recorded neural activity as well as by the animal behavior within a specifically designed experimental setup. An intuitive graphical user interface was developed to configure and to monitor the whole system. The system was successfully tested through bench tests and in vivo measurements on behaving rats chronically implanted with multi-channels microwire arrays.


Assuntos
Comportamento Animal/fisiologia , Interfaces Cérebro-Computador , Tecnologia de Sensoriamento Remoto/instrumentação , Tecnologia sem Fio/instrumentação , Potenciais de Ação/fisiologia , Animais , Estimulação Elétrica , Eletrodos Implantados , Desenho de Equipamento , Masculino , Ratos , Ratos Long-Evans , Processamento de Sinais Assistido por Computador/instrumentação , Córtex Somatossensorial/fisiologia , Córtex Somatossensorial/cirurgia , Técnicas Estereotáxicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA