Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Environ Sci Technol ; 52(15): 8488-8500, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29979581

RESUMO

Traces of particulate radioactive iodine (131I) were detected in the European atmosphere in January/February 2017. Concentrations of this nuclear fission product were very low, ranging 0.1 to 10 µBq m-3 except at one location in western Russia where they reached up to several mBq m-3. Detections have been reported continuously over an 8-week period by about 30 monitoring stations. We examine possible emission source apportionments and rank them considering their expected contribution in terms of orders of magnitude from typical routine releases: radiopharmaceutical production units > sewage sludge incinerators > nuclear power plants > spontaneous fission of uranium in soil. Inverse modeling simulations indicate that the widespread detections of 131I resulted from the combination of multiple source releases. Among them, those from radiopharmaceutical production units remain the most likely. One of them is located in Western Russia and its estimated source term complies with authorized limits. Other existing sources related to 131I use (medical purposes or sewage sludge incineration) can explain detections on a rather local scale. As an enhancing factor, the prevailing wintertime meteorological situations marked by strong temperature inversions led to poor dispersion conditions that resulted in higher concentrations exceeding usual detection limits in use within the informal Ring of Five (Ro5) monitoring network.


Assuntos
Poluentes Radioativos do Ar , Neoplasias da Glândula Tireoide , Europa (Continente) , Humanos , Radioisótopos do Iodo , Federação Russa
2.
Appl Radiat Isot ; 205: 111182, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38232489

RESUMO

A metrologically consistent procedure for assessing the detection limits of activity measurements for gamma-ray emitters with high-resolution spectrometers using the LSQ method is described and tested. As the input to the assessment, besides the measured contents of the spectral channels, the results of the peak analysis, i.e., the indication and its uncertainty, are used. The unfolding of the spectral region of interest into its components corresponding to the peak representing the indication and its background allows us to take into account the uncertainty budget, describing the uncertainty of the indication and the shape of the corresponding peak, making possible to include these sources of uncertainty in the calculation of the decision threshold. To assess the detection limit, the variance of the indication is calculated as a function of the indication itself, while considering the relative uncertainty of the conversion factor. The variance of the indication observed is approximated by a polynomial of the second order of the indication, thus making it possible to calculate the detection limit analytically. The method was tested on measured spectra using the empirically determined spectral shape of the peak representing the indication. It was shown how the empirically determined shape of an isolated and expressive peak close to the peak representing the indication can be used in the calculation of the decision threshold and how the presence of a peak overlapping with the peak representing the indication affects the decision threshold and the detection limit. It is explained that besides the counting statistics, the sources of uncertainty due to the shape of the peak representing indication also contribute to the decision threshold. However, to the increase of the detection limit over the decision threshold, besides the counting statistic, only the uncertainty of the conversion factor contributes. It is shown that in the presence of the indication, the decision threshold and the detection limit can be used to quantify the comparison between the observed value and the true value of the measurand with a predetermined quantity value in terms of the probabilities of making errors of the first and second kind. The application of the decision thresholds and detection limits to a conformity assessment is proposed.

3.
Appl Radiat Isot ; 194: 110683, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36709608

RESUMO

The count rate in the peak of a gamma-ray spectrum at 2223 keV was measured over a period of 25 years. The peak is produced by neutron capture on hydrogen, a constituent of the spectrometer's shield. Since the neutrons are produced by cosmic rays, the count rate in the peak is correlated with the solar activity via the interaction between the solar wind and the cosmic rays. The correlation between the total daily number of sunspots, as a measure of the solar activity, and the count rate in the peak was investigated as a function of the time shift between the time dependence of the count rate in the peak and the time dependence of the total daily number of sunspots. Variations of the correlation coefficient as a function of the shift are discussed in terms of phenomena occurring on the surface of the Sun. The variations indicate a long-term correlation, corresponding to the 11-year solar cycle, and a short-term correlation, corresponding to the sunspots.

4.
Appl Radiat Isot ; 193: 110682, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36682310

RESUMO

The method of calculation of the decision threshold with the Least Squares Method, described in the standard ISO 11929, is presented for the case when the sources of peaked background contribute to the peak holding the indication. The decision threshold is calculated from spectral data corresponding to the indication zero; therefore, the observed indication must be removed from the spectrum. When the peaked background is present, the indication completely overlaps with the peaked background, so it can't be unfolded directly. Therefore, two steps are needed in the calculation: the unfolding of the peak, housing the indication, from the continuous background and the possible overlapping peaks, and separating of the indication from the peaked background using the background data obtained from separate calculations and measurements. In this article it is shown that the method of least squares is flexible enough to accommodate all sources of uncertainty into the uncertainty matrix of input quantities. Its derivation is presented in detail and the calculation of the indication corresponding to the decision threshold is described. As a proof of the concept an example of calculating the number of counts corresponding to the decision threshold as a function of the indication is presented. The method of calculation and the results of the calculation are briefly discussed.

5.
J Environ Radioact ; 242: 106770, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34864504

RESUMO

This paper compares the Morris, Spearman and Sobol' methods of sensitivity analysis in radiological risk assessment. The determination of the most influential parameters on model with regards to the propagation of their uncertainties to output variables, is of greatest interest. This study aims to determine the relative importance of parameters uncertainties on the dose calculation uncertainty in the framework of a scenario of routine discharges discussed in the context of an IAEA working group. The scenario considers atmospheric and liquid discharges of three different types of radionuclides (14C, tritium as HTO and 110mAg) from a nuclear power plant located by the side of a river. It is concluded that the most reliable and practical method according to the ability of ranking influential parameters and the easiness of its application is the Spearman method. As key result, the three first influential variables for annual total dose for all pathways and all radionuclides were the water dissolved inorganic carbon concentration, the volatilisation rate constant and the soil layer solid liquid distribution in 14C.


Assuntos
Centrais Nucleares , Monitoramento de Radiação
6.
Appl Radiat Isot ; 158: 109063, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32174377

RESUMO

An account is given on the value of the correlation coefficient between the number of counts in a peak in a gamma-ray spectrum and the number of counts in the background, where the peak resides. It is supposed that the decomposition of the spectrum in the peak and in the background is performed by using the Least Squares method. The values of the correlation coefficient were determined empirically from measurements of gamma-ray spectra under repeatable conditions and from analyses of these spectra using four different kinds of peak-analysis software. These values were compared to the a-priori values, obtained from the Least Squares method.

7.
Appl Radiat Isot ; 155: 108920, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31622844

RESUMO

The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%. Locating peaks at these relatively high peak-area uncertainties with a probability greater than 0.95 is only possible in the library-driven mode, where the peak positions are supposed a-priori. The deficiencies of the library-driven mode and the possibilities to improve the probabilities of locating peaks are briefly discussed.

8.
Appl Radiat Isot ; 133: 22-30, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29274523

RESUMO

A new method for calculating the detection limits of gamma-ray spectrometry measurements is presented. The method is applicable for gamma-ray emitters, irrespective of the influences of the peaked background, the origin of the background and the overlap with other peaks. It offers the opportunity for multi-gamma-ray emitters to calculate the common detection limit, corresponding to more peaks. The detection limit is calculated by approximating the dependence of the uncertainty in the indication on its value with a second-order polynomial. In this approach the relation between the input quantities and the detection limit are described by an explicit expression and can be easy investigated. The detection limit is calculated from the data usually provided by the reports of peak-analyzing programs: the peak areas and their uncertainties. As a result, the need to use individual channel contents for calculating the detection limit is bypassed.

9.
Appl Radiat Isot ; 134: 56-58, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28843734

RESUMO

Two effects were identified that induce the dependence of the decision threshold on the uncertainty of the conversion factor. With the first effect, the conversion factor influences the decision threshold directly, through its variability. With the second effect, the variability of the conversion factor influences the decision threshold only when it is not evaluated for the null measurement. Then, the variability of the conversion factor influences the value of the measurand, where the decision threshold is evaluated. Both effects are explained and evaluated.

10.
Appl Radiat Isot ; 134: 51-55, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28673731

RESUMO

A method is presented for calculating the expected number of counts in peaks that have a large relative peak-area uncertainty and appear in measured gamma-ray spectra. The method was applied to calculations of the correction factors for peaks occurring in the spectra of radon daughters. It was shown that the factors used for correcting the calculated peak areas to their expected values decrease with an increasing relative peak-area uncertainty. The accuracy of taking the systematic influence inducing the correction factors into account is given by the dispersion of the correction factors corresponding to specific peaks. It was shown that the highest accuracy is obtained in the peak analyses with the GammaVision and Gamma-W software.

11.
Radiat Prot Dosimetry ; 125(1-4): 117-20, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17606480

RESUMO

A programme of harmonization of individual dosimetry quality control organized in the framework of a distributed metrology system is presented as seen from the experiences gained in Slovenia. As a part of the programme intercomparison of dosimetry services was organized and basic characteristics of dosimetry systems compared. Results are discussed with suggestions for further improvements of quality assurance.


Assuntos
Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Medição de Risco/normas , Dosimetria Termoluminescente/normas , Carga Corporal (Radioterapia) , Humanos , Internacionalidade , Exposição Ocupacional/prevenção & controle , Controle de Qualidade , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Eslovênia
12.
Appl Radiat Isot ; 121: 126-130, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28063382

RESUMO

In gamma-ray spectrometry the measurement threshold describes the lover boundary of the interval of peak areas originating in the response of the spectrometer to gamma-rays from the sample measured. In this sense it presents a generalization of the net indication corresponding to the decision threshold, which is the measurement threshold at the quantity value zero for a predetermined probability for making errors of the first kind. Measurement thresholds were determined for peaks appearing in the spectra of radon daughters 214Pb and 214Bi by measuring the spectrum 35 times under repeatable conditions. For the calculation of the measurement threshold the probability for detection of the peaks and the mean relative uncertainty of the peak area were used. The relative measurement thresholds, the ratios between the measurement threshold and the mean peak area uncertainty, were determined for 54 peaks where the probability for detection varied between some percent and about 95% and the relative peak area uncertainty between 30% and 80%. The relative measurement thresholds vary considerably from peak to peak, although the nominal value of the sensitivity parameter defining the sensitivity for locating peaks was equal for all peaks. At the value of the sensitivity parameter used, the peak analysis does not locate peaks corresponding to the decision threshold with the probability in excess of 50%. This implies that peaks in the spectrum may not be located, although the true value of the measurand exceeds the decision threshold.

13.
Appl Radiat Isot ; 126: 267-269, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28237290

RESUMO

A method for calculating the approximate value of the detection limit for measurements of ionizing radiation is presented. The method can be applied when the indication corresponding to the detection limit and its uncertainty are given as explicit functions. Then also the detection limit can be calculated explicitly, which means that the iteration procedure for its calculation can be avoided. The advantage of the method becomes apparent when the iteration process for calculating the detection limit is difficult to apply.

14.
Radiat Prot Dosimetry ; 121(2): 191-4, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16410289

RESUMO

Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Müller counters and a network of measuring sites with high-sensitive thermoluminiscence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation.


Assuntos
Raios gama , Garantia da Qualidade dos Cuidados de Saúde/métodos , Monitoramento de Radiação , Contaminação Radioativa do Ar , Humanos , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Radiometria , Eslovênia , Dosimetria Termoluminescente
15.
Radiat Prot Dosimetry ; 119(1-4): 300-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16735564

RESUMO

The responses of readings by the TL dosimetry system MR200 TL developed in-house and used at JSI and the TOLEDO TL system used at RBI are compared. Ten measurements at different doses ranging from 0.01 mSv to 5 Sv were carried out. A set of 36 dosemeters with three pellets of CaF2:Mn were irradiated in radiation fields of 137Cs and 60Co. Analysis of the measured results shows that at doses below 0.1 Sv, readers' outputs do not differ >5% from each other. At doses >1 Sv, the results obtained by the MR200 reader must be corrected with a known factor. Finally, the reproducibility of the results from the MR200 was tested.


Assuntos
Fluoreto de Cálcio/química , Fluoreto de Cálcio/efeitos da radiação , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Manganês/química , Manganês/efeitos da radiação , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
16.
Appl Radiat Isot ; 118: 1-6, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27571962

RESUMO

Two simple methods for calculating the correlations between peaks appearing in gamma-ray spectra are described. We show how the areas are correlated when the peaks do not overlap, but the spectral regions used for the calculation of the background below the peaks do. When the peaks overlap, the correlation can be stronger than in the case of the non-overlapping peaks. The methods presented are simplified to the extent of allowing their implementation with manual calculations. They are intended for practitioners as additional tools to be used when the correlations between the areas of the peaks in the gamma-ray spectra are to be calculated. Also, the correlation coefficient between the number of counts in the peak and the number of counts in the continuous background below the peak is derived.

17.
Appl Radiat Isot ; 109: 522-525, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26625726

RESUMO

In the presence of radon daughters, gamma rays from (88)Y with energies at 898.0keV or 1836.1keV appear on a high, continuous background or overlap with other peaks. Therefore a calculation of the decision threshold from the sum peak at 2734.1keV represents a useful alternative, because here the continuous background is low. The decision threshold calculated from this peak can attain a value being comparable to the decision threshold calculated from the gamma-ray peak at 898.0keV.

18.
Appl Radiat Isot ; 109: 518-521, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26671790

RESUMO

In gamma-ray spectrometric measurements the background is usually taken into account by conducting measurements on a blank sample. However, this method is not appropriate if many different kinds of samples are measured and several types of detectors are used. In such cases it is easier to measure accurately the activities of the blank materials separately and then to subtract the activities of the blank sample from the total sample activities. In order to do this, the measurement function for the activity calculation must be modified.

19.
Appl Radiat Isot ; 105: 60-65, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26248084

RESUMO

When measurement results with values near the decision threshold are being considered, a relative uncertainty of 60% is expected. Since such measurement results can be reported, the performance of the peak-analysing software for gamma-ray spectra needs to be examined for peaks that have a large relative uncertainty. The investigation was performed on a series of spectra measured with a HPGe detector under identical counting conditions. It was found that under a limit value of the relative peak area uncertainty the peak-analysis results are reliable with respect to both the peak location and the peak area evaluation. At relative uncertainties exceeding this uncertainty, the probability of type-II errors increases and a systematic influence on the peak area occurs, which originates in fluctuations of the continuous background in the vicinity of the peak. For the counting conditions used in this investigation, the limit relative uncertainty is about 35%, and whereas a systematic influence can be taken into account by a correction factor, the frequency of the type-II errors can only be reduced at the expense of increasing the frequency of the type-I errors.

20.
Pflugers Arch ; 439(Suppl 1): r184-r186, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28176117

RESUMO

The effect of biphasic electric fields on nerve regeneration that follows injury to the left radial nerve of a dog was examined using electromyography (EMG). The left and right radial nerves were crushed with a serrated hemostat and the stimulating electrodes were positioned proximally and distally relative to the site of the injury. The left nerves received rectangular, biphasic current pulses (30µA, 0.5Hz) through the lesion for two months. The right radial nerves were treated as controls and regenerated without electrical stimulation. EMG activity was recorded intramuscularly from left and right musculus extensor digitorum (from Medical dictionary) communis (MEDC). Results obtained at the end of the two-month stimulation period showed a significant difference between the EMG activity of the stimulated and the unstimulated MEDC suggesting that the electrical treatment enhanced the nerve regeneration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA