Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Clin Ultrasound ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39235299

RESUMO

PURPOSE: This study aims to assess the diagnostic efficacy of Korean Thyroid imaging reporting and data system (K-TIRADS), S-Detect software and contrast-enhanced ultrasound (CEUS) when employed individually, as well as their combined application, for the evaluation of thyroid nodules, with the objective of identifying the optimal method for diagnosing thyroid nodules. METHODS: Two hundred and sixty eight cases pathologically proven of thyroid nodules were retrospectively enrolled. Each nodule was classified according to K-TIRADS. S-Detect software was utilized for intelligent analysis. CEUS was employed to acquire contrast-enhanced features. RESULTS: The area under curve (AUC) values for diagnosing benign and malignant thyroid nodules using K-TIRADS alone, S-Detect software alone, CEUS alone, the combined application of K-TIRADS and CEUS, the combined application of S-Detect software and CEUS were 0.668, 0.668, 0.719, 0.741, and 0.759, respectively (p < 0.001). The sensitivity rate of S-Detect software was 89.9% (p < 0.001). It was the highest of the five diagnostic methods above. CONCLUSION: The utilization of S-Detect software can be served as a powerful tool for early screening. Notably, the combined utilization of S-Detect software with CEUS demonstrates superior diagnostic performance compared to employing K-TIRADS, S-Detect software, CEUS used individually, as well as the combined application of K-TIRADS with CEUS.

2.
Acta Pharmacol Sin ; 39(7): 1208-1216, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29795360

RESUMO

Due to the lack of typical clinical symptoms, the average delay time for diagnosis of pulmonary hypertension (PH) is longer than 2 years. It is urgent to find biomarkers for PH diagnosis. In this study we investigated whether plasma microRNAs (miRNAs) can be used as biomarkers for PH diagnosis. We used microarray to identify dynamic miRNAs between PH and non-PH patients. The candidate miRNAs were verified using qRT-PCR in a mouse model of PH, which was induced by monocrotaline (MCT) injection. We observed that miR-21, miR-126, miR-145, miR-191 and miR-150 had no differences between control mice and MCT-treated mice; but plasma miR-451 was significantly decreased in the 2wk-MCT group, with no further decrease in the 4wk-MCT group. Plasma miR-451 was also markedly decreased in PH patients, whereas miR-21, miR-126, miR-150 and miR-320 did not show differences between 53 PH patients and 54 non-PH patients. Receiver operating characteristic curves (ROCs) were constructed from the patient data to assess the clinical diagnostic values of circulating miR-451 and Doppler echocardiography (D-ECHO). The areas under the curve (AUCs) of ROCs for miR-451 and D-ECHO were 0.710 and 0.766, respectively. Combination of miR-451 and D-ECHO with AUC of 0.825 was superior to the use of either miR-451 or D-ECHO alone for PH diagnosis. In conclusion, plasma miR-451 has a moderate diagnostic value in PH comparable to that of D-ECHO, and the combination of miR-451 with D-ECHO has better diagnostic value than either method alone, which may have implications for PH diagnosis.


Assuntos
Ecocardiografia , Hipertensão Pulmonar/sangue , Hipertensão Pulmonar/diagnóstico , MicroRNAs/sangue , Animais , Biomarcadores/sangue , Masculino , Camundongos , Camundongos Endogâmicos C57BL
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA