Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 219
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(20): 1804-1815, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38583086

RESUMO

BACKGROUND AND AIMS: In patients with three-vessel disease and/or left main disease, selecting revascularization strategy based on coronary computed tomography angiography (CCTA) has a high level of virtual agreement with treatment decisions based on invasive coronary angiography (ICA). METHODS: In this study, coronary artery bypass grafting (CABG) procedures were planned based on CCTA without knowledge of ICA. The CABG strategy was recommended by a central core laboratory assessing the anatomy and functionality of the coronary circulation. The primary feasibility endpoint was the percentage of operations performed without access to the ICA. The primary safety endpoint was graft patency on 30-day follow-up CCTA. Secondary endpoints included topographical adequacy of grafting, major adverse cardiac and cerebrovascular (MACCE), and major bleeding events at 30 days. The study was considered positive if the lower boundary of confidence intervals (CI) for feasibility was ≥75% (NCT04142021). RESULTS: The study enrolled 114 patients with a mean (standard deviation) anatomical SYNTAX score and Society of Thoracic Surgery score of 43.6 (15.3) and 0.81 (0.63), respectively. Unblinding ICA was required in one case yielding a feasibility of 99.1% (95% CI 95.2%-100%). The concordance and agreement in revascularization planning between the ICA- and CCTA-Heart Teams was 82.9% with a moderate kappa of 0.58 (95% CI 0.50-0.66) and between the CCTA-Heart Team and actual treatment was 83.7% with a substantial kappa of 0.61 (95% CI 0.53-0.68). The 30-day follow-up CCTA in 102 patients (91.9%) showed an anastomosis patency rate of 92.6%, whilst MACCE was 7.2% and major bleeding 2.7%. CONCLUSIONS: CABG guided by CCTA is feasible and has an acceptable safety profile in a selected population of complex coronary artery disease.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária , Doença da Artéria Coronariana , Estudos de Viabilidade , Humanos , Ponte de Artéria Coronária/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estudos Prospectivos , Grau de Desobstrução Vascular/fisiologia
2.
Eur Radiol ; 34(3): 1836-1845, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658136

RESUMO

OBJECTIVES: Computed tomography (CT)-derived fractional flow reserve (FFRCT) decreases continuously from proximal to distal segments of the vessel due to the influence of various factors even in non-obstructive coronary artery disease (NOCAD). It is known that FFRCT is dependent on vessel-length, but the relationship with other vessel morphologies remains to be explained. PURPOSE: To investigate morphological aspects of the vessels that influence FFRCT in NOCAD in the right coronary artery (RCA). METHODS: A total of 443 patients who underwent both FFRCT and invasive coronary angiography, with < 50% RCA stenosis, were evaluated. Enrolled RCA vessels were classified into two groups according to distal FFRCT: FFRCT ≤ 0.80 (n = 60) and FFRCT > 0.80 (n = 383). Vessel morphology (vessel length, lumen diameter, lumen volume, and plaque volume) and left-ventricular mass were assessed. The ratio of lumen volume and vessel length was defined as V/L ratio. RESULTS: Whereas vessel-length was almost the same between FFRCT ≤ 0.80 and > 0.80, lumen volume and V/L ratio were significantly lower in FFRCT ≤ 0.80. Distal FFRCT correlated with plaque-related parameters (low-attenuation plaque, intermediate-attenuation plaque, and calcified plaque) and vessel-related parameters (proximal and distal vessel diameter, vessel length, lumen volume, and V/L ratio). Among all vessel-related parameters, V/L ratio showed the highest correlation with distal FFRCT (r = 0.61, p < 0.0001). Multivariable analysis showed that calcified plaque volume was the strongest predictor of distal FFRCT, followed by V/L ratio (ß-coefficient = 0.48, p = 0.03). V/L ratio was the strongest predictor of a distal FFRCT ≤ 0.80 (cut-off 8.1 mm3/mm, AUC 0.88, sensitivity 90.0%, specificity 76.7%, 95% CI 0.84-0.93, p < 0.0001). CONCLUSIONS: Our study suggests that V/L ratio can be a measure to predict subclinical coronary perfusion disturbance. CLINICAL RELEVANCE STATEMENT: A novel marker of the ratio of lumen volume to vessel length (V/L ratio) is the strongest predictor of a distal CT-derived fractional flow reserve (FFRCT) and may have the potential to improve the diagnostic accuracy of FFRCT. KEY POINTS: • Physiological FFRCT decline depends not only on vessel length but also on the lumen volume in non-obstructive coronary artery disease in the right coronary artery. • FFRCT correlates with plaque-related parameters (low-attenuation plaque, intermediate-attenuation plaque, and calcified plaque) and vessel-related parameters (proximal and distal vessel diameter, vessel length, lumen volume, and V/L ratio). • Of vessel-related parameters, V/L ratio is the strongest predictor of a distal FFRCT and an optimal cut-off value of 8.1 mm3/mm.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Índice de Gravidade de Doença
3.
Neuroradiology ; 66(4): 487-506, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38240767

RESUMO

PURPOSE: To assess the performance of the inferior lateral ventricle (ILV) to hippocampal (Hip) volume ratio on brain MRI, for Alzheimer's disease (AD) diagnostics, comparing it to individual automated ILV and hippocampal volumes, and visual medial temporal lobe atrophy (MTA) consensus ratings. METHODS: One-hundred-twelve subjects (mean age ± SD, 66.85 ± 13.64 years) with varying degrees of cognitive decline underwent MRI using a Philips Ingenia 3T. The MTA scale by Scheltens, rated on coronal 3D T1-weighted images, was determined by three experienced radiologists, blinded to diagnosis and sex. Automated volumetry was computed by icobrain dm (v. 5.10) for total, left, right hippocampal, and ILV volumes. The ILV/Hip ratio, defined as the percentage ratio between ILV and hippocampal volumes, was calculated and compared against a normative reference population (n = 1903). Inter-rater agreement, association, classification accuracy, and clinical interpretability on patient level were reported. RESULTS: Visual MTA scores showed excellent inter-rater agreement. Ordinal logistic regression and correlation analyses demonstrated robust associations between automated brain segmentations and visual MTA ratings, with the ILV/Hip ratio consistently outperforming individual hippocampal and ILV volumes. Pairwise classification accuracy showed good performance without statistically significant differences between the ILV/Hip ratio and visual MTA across disease stages, indicating potential interchangeability. Comparison to the normative population and clinical interpretability assessments showed commensurability in classifying MTA "severity" between visual MTA and ILV/Hip ratio measurements. CONCLUSION: The ILV/Hip ratio shows the highest correlation to visual MTA, in comparison to automated individual ILV and hippocampal volumes, offering standardized measures for diagnostic support in different stages of cognitive decline.


Assuntos
Doença de Alzheimer , Lobo Temporal , Humanos , Lobo Temporal/patologia , Doença de Alzheimer/patologia , Ventrículos Laterais , Atrofia/patologia , Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos
4.
Eur Radiol ; 33(2): 1277-1285, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36114847

RESUMO

OBJECTIVES: Computed tomography (CT) derived fractional flow reserve (FFRCT) decreases from the proximal to the distal part due to a variety of factors. The energy loss due to the bifurcation angle may potentially contribute to a progressive decline in FFRCT. However, the association of the bifurcation angle with FFRCT is still not entirely understood. This study aimed to investigate the impact of various bifurcation angles on FFRCT decline below the clinically crucial relevance of 0.80 in vessels with no apparent coronary artery disease (CAD). METHODS: A total of 83 patients who underwent both CT angiography including FFRCT and invasive coronary angiography, exhibiting no apparent CAD were evaluated. ΔFFRCT was defined as the change in FFRCT from the proximal to the distal in the left anterior descending artery (LAD) and left circumflex artery (LCX). The bifurcation angle was calculated from three-dimensional volume rendered images. Vessel morphology and plaque characteristics were also assessed. RESULTS: ΔFFRCT significantly correlated with the bifurcation angle (LAD angle, r = 0.35, p = 0.001; LCX angle, r = 0.26, p = 0.02) and vessel length (LAD angle, r = 0.30, p = 0.005; LCX angle, r = 0.49, p < 0.0001). In LAD, vessel length was the strongest predictor for distal FFRCT of ≤ 0.80 (ß-coefficient = 0.55, p = 0.0003), immediately followed by the bifurcation angle (ß-coefficient = 0.24, p = 0.02). The bifurcation angle was a good predictor for a distal FFRCT ≤ 0.80 (LAD angle, cut-off 31.0°, AUC 0.70, sensitivity 74%, specificity 68%; LCX angle, cut-off 52.6°, AUC 0.86, sensitivity 88%, specificity 85%). CONCLUSIONS: In vessels with no apparent CAD, vessel length was the most influential factor on FFRCT, directly followed by the bifurcation angle. KEY POINTS: • Both LAD and LCX bifurcation angles are factors influencing FFR CT. • Bifurcation angle is one of the predictors of a distal FFRCT of ≤ 0.80 and an optimal cut-off value of 31.0° for the LAD and 52.6° for the LCX. • Bifurcation angle should be taken into consideration when interpreting numerical values of FFRCT.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/anatomia & histologia , Coração , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
5.
Heart Vessels ; 38(6): 757-763, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36607386

RESUMO

To evaluate coronary artery disease (CAD) with computed tomography coronary angiography (CTCA)-derived fractional flow reserve (FFR) in patients with atrial fibrillation (AF) requiring ablation. The study population consisted of 151 patients who underwent CTCA before AF ablation (AF group), and a control group of 151 patients from the outpatient clinic who underwent CTCA without any history of AF (non-AF group), matched for age, sex, BMI, and angina symptomatology. All study patients underwent CTCA with subdivision of coronary lesion type into severe (≥ 70% luminal narrowing), moderate (50% ≤ luminal narrowing < 70%), and mild stenosis (< 50% luminal narrowing). In patients with ≥ 1 moderate or severe stenosis, non-invasive FFR was calculated from CTCA (FFRCT). Baseline characteristics and CAD risk factors were similar between the 2 groups. During CTCA, 38% of the patients in the AF group were in ongoing atrial arrhythmia (either AF or regular atrial tachycardia). The number of patients with severe (10 (6.6%) vs 10 (6.6%), P = 1.00), moderate (14 (9.5%) vs 10 (6.7%), P = 0.4), and mild stenosis (43 (28.5%) vs 56 (37.1%), P = 0.11) was not significantly different between the 2 groups. Performance of FFRCT was feasible in 32/44 patients (73%), and failed in 27% of the patients (7 and 5 patients in the AF and non-AF group, respectively, P = 0.74). No difference was observed in the prevalence of hemodynamically significant stenosis (FFRCT ≤ 0.80) (15 (9.9%) vs 12 (7.9%), P = 0.85). Our study showed technical feasibility of CTCA in all patients of both groups, including the patients with AF as presenting rhythm. The FFRCT add-on analysis failed equally frequent in patients of the AF versus non-AF group. An equal rate of CAD was observed in the AF group and non-AF group, favoring the concept of shared associated risk factors for CAD and AF.


Assuntos
Fibrilação Atrial , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Constrição Patológica , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Valor Preditivo dos Testes , Vasos Coronários
6.
Echocardiography ; 40(2): 103-112, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36607158

RESUMO

BACKGROUND: The ramus artery contributes to the development of turbulence, which may influence computed tomography (CT) derived fractional flow reserve (FFRCT ) even without coronary artery disease (CAD). The relationship between ramus-induced turbulence and FFRCT is unclear. METHOD AND RESULTS: A total of 120 patients with <20% coronary stenosis assessed by both FFRCT and invasive coronary angiography were evaluated. The patients were divided into three groups: absent-ramus (n = 72), small-ramus that could not be analyzed by FFRCT (n = 18), and large-ramus that could be analyzed by FFRCT (n = 30). FFRCT measurements were performed at the proximal and distal segments of the left anterior descending (LAD), left circumflex (LCX), and ramus artery. With absent-ramus and small-absent ramus groups, FFRCT was measured at the distal end of the left main trunk at the same level for the proximal segments of the LAD and LCX. In absent-ramus group, proximal FFRCT showed no significant differences between three vessels (LAD = .96 ± .02; MID = .97 ± .02; LCX = .97 ± .02). However, in small and large-ramus groups, proximal FFRCT was significantly higher in the ramus artery than LAD and LCX (small-ramus, LAD = .95 ± .03, Ramus = .97 ± .02, LCX = .95 ± .03; large-ramus: LAD = .95 ± .03, Ramus = .98 ± .01; LCX = .96 ± .03; p < .05). A large ramus was associated with a higher prevalence of a distal FFRCT ≤.80 (odds ratio 7.0, 95% CI 1.2-40.1, p = .03). A proximal ramus diameter predicted distal FFRCT ≤.80 (cut-off 2.1 mm, AUC .76, sensitivity 100%, specificity 52%, 95% CI .61-.90). CONCLUSIONS: The presence of a large-ramus artery may cause an FFRCT decline in no apparent CAD.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Estenose Coronária/diagnóstico por imagem , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes
7.
Acta Radiol ; 64(8): 2387-2392, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37138465

RESUMO

BACKGROUND: Iodine contrast agent (CA) is widely used in cardiac computed tomography (CT). The CA can increase the organ radiation doses due to the photoelectric effect. PURPOSE: To investigate the impact of CA on radiation dose in cardiac CT by comparing the radiation dose between contrast coronary CT angiography (CCTA) and non-contrast calcium scoring CT (CSCT). MATERIAL AND METHODS: Radiation doses were computationally calculated for 30 individual patients who received CSCT and CCTA in the same exam session. The geometry and acquisition parameters were modeled in the simulations based on individual patient CT images and acquisitions. Doses in the presence and absence of CA were obtained in the aorta, left ventricle (LV), right ventricle (RV), and myocardial tissue (MT). The dose values were normalized by size-specific dose estimate (SSDE). The dose enhancement factors (DEFSSDE) were calculated as the ratio of doses in CCTA over doses in CSCT. RESULTS: Compared to the CSCT scans, doses increase in the CCTA scans in the aorta (DEFSSDE = 2.14 ± 0.20), LV (DEFSSDE = 1.78 ± 0.26), and RV (DEFSSDE = 1.31 ± 0.22). A linear relation is observed between the local CA concentrations and the dose increase in the heart; DEFSSDE = 0.07*I(mg/mL) + 0.80 (R2 = 0.8; p < 0.01). The DEFSSDE in the MT (DEFSSDE = 0.96 ± 0.08) showed no noticeable impact of CA on the dose in this tissue. In addition, patient variability in the dose distributions was observed. CONCLUSION: A linear causal relation exists between local CA concentration and increase in radiation dose in cardiac CT. For the same CT exposure, dose to the heart is on average 55% higher in contrast cardiac CT.


Assuntos
Cálcio , Meios de Contraste , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
8.
J Appl Clin Med Phys ; 24(1): e13867, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36537145

RESUMO

BACKGROUND: Unoptimized coronary CT angiography (CTA) exams typically result in a highly variable arterial enhancement (HUa ) across patients. This study aimed at harmonizing arterial enhancement by implementing a patient-, contrast- and kV-tailored injection protocol. METHODS: First, the optimal body size metric to predict HUa was identified by retrospectively analysing images of 76 patients, acquired with 70 ml contrast media (G1). Second, using phantom experiments, correction factors for the effect of kV and contrast concentration on HUa were determined. Third, a model was developed, prescribing the optimal contrast dose to be injected to obtain a diagnostically appropriate arterial target enhancement HUtarget . The model was then validated on 278 prospectively collected patients, in two groups with two different HUtarget : 525 HU (207 patients, G2A) and 425 HU (71 patients, G2B). The HUa histograms were compared among groups and to the target enhancement through their mean and standard deviation (SD) at 100 kVp reference level. Also, signal-to-noise ratio was obtained and compared among the groups. RESULTS: Fat free mass (FFM) showed the highest correlation with HUa (r = 0.69). KVp correction factors ranged from 0.65 at 70 kVp to 1.22 at 140 kVp. The obtained model reduced the group heterogeneity (SD) from 101HU for reference G1 to 75HU (p < 0.001) for G2A and 68HU (p < 0.001) for G2B. The mean HUa of 506HU in G2A was slightly below HUtarget  = 525HU (p = 0.01) whereas in G2B, the mean HUa of 414HU was not significantly different from HUtarget  = 425HU (p = 0.54). The total iodine dose was lowered from 19.5 g-I to 17.6 g-I and 14.2 g-I from G1 to G2A and G2B, on average. CONCLUSION: A contrast injection model, based on patient's fat free mass and accounting for the contrast agent concentration and the planned CT-scan tube voltage, harmonized arterial enhancement among patients towards a predefined target enhancement in coronary CTA scanning, without affecting the bolus timing.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Doses de Radiação
9.
Surg Radiol Anat ; 45(2): 193-199, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36646907

RESUMO

OBJECTIVES: To compare the amount of fluid in synovial sheaths of the ankle before and after running. Our hypothesis was that this amount would increase and that the threshold for what is normally acceptable should be adjusted after physical activity. METHODS: Twenty-one healthy volunteers (n = 42 ankles) ran for 40 min on a treadmill. They underwent 3 T MRI before and immediately after running using a dedicated ankle coil. The images were stored and subsequently measured in a standardized way and independently read by two readers for fluid in the tendon sheaths in the retro and inframalleolar area. Statistics were performed for each tendon (Wilcoxon signed rank test), and also for the pooled data. Intraclass correlation coefficients were calculated. RESULTS: For reader 1, for all tendons the values after running increased without reaching statistical significance. For reader 2 this was not the case for all tendons but for most. When all the data were pooled (n = 800 measurements), the statistical difference before and after running was significant (p < 0.001). CONCLUSION: Data pre and post-running show a trend of increasing synovial fluid, however, not significant for each individual tendon. The pooled data for all tendons, (n = 800) show a statistically significant increase after running (p < 0.001). The clinical implication is that the threshold for normally acceptable fluid should be adjusted if the patient undergoes an MR study after recent physical activity.


Assuntos
Tornozelo , Corrida , Humanos , Líquido Sinovial , Articulação do Tornozelo/diagnóstico por imagem , Tendões/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
10.
Eur J Neurol ; 29(10): 3039-3049, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35737867

RESUMO

BACKGROUND AND PURPOSE: Data from neuro-imaging techniques allow us to estimate a brain's age. Brain age is easily interpretable as 'how old the brain looks' and could therefore be an attractive communication tool for brain health in clinical practice. This study aimed to investigate its clinical utility by investigating the relationship between brain age and cognitive performance in multiple sclerosis (MS). METHODS: A linear regression model was trained to predict age from brain magnetic resonance imaging volumetric features and sex in a healthy control dataset (HC_train, n = 1673). This model was used to predict brain age in two test sets: HC_test (n = 50) and MS_test (n = 201). Brain-predicted age difference (BPAD) was calculated as BPAD = brain age minus chronological age. Cognitive performance was assessed by the Symbol Digit Modalities Test (SDMT). RESULTS: Brain age was significantly related to SDMT scores in the MS_test dataset (r = -0.46, p < 0.001) and contributed uniquely to variance in SDMT beyond chronological age, reflected by a significant correlation between BPAD and SDMT (r = -0.24, p < 0.001) and a significant weight (-0.25, p = 0.002) in a multivariate regression equation with age. CONCLUSIONS: Brain age is a candidate biomarker for cognitive dysfunction in MS and an easy to grasp metric for brain health.


Assuntos
Disfunção Cognitiva , Esclerose Múltipla , Biomarcadores , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Cognição , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/etiologia , Humanos , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Testes Neuropsicológicos
11.
Echocardiography ; 39(2): 398-403, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35066936

RESUMO

A total of 1335 outpatients with suspected coronary artery disease and who underwent computed tomography derived fractional flow reserve (FFRCT ) analysis were examined. Only four patients showed reverse increase of FFRCT from the proximal to the distal vessel and all of them had a large ramus artery (RAM). Of all parameters (vessel length, lumen volume, plaque volume, and left ventricular mass), only the bifurcation angle was significantly higher in reverse increase of FFRCT with RAM group (106.0 ± 15.8°) than normal FFRCT with RAM group (82.6 ± 21.7°) and normal FFRCT without RAM group (66.9 ± 21.1°).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
12.
Eur Radiol ; 31(10): 7540-7549, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33783569

RESUMO

OBJECTIVES: Routine dosimetry calculations do not account for the presence of iodine in organs and tissues during CT acquisition. This study aims to investigate the impact of contrast agent (CA) on radiation dose. METHODS: First, relation between absorbed radiation dose and iodine concentrations was investigated using a cylindrical water phantom with iodine-saline dilution insertions. Subsequently, a retrospective study on abdominal dual-energy CT (DECT) patient data was performed to assess the increase of the local absorbed radiation dose compared to a non-contrast scan. Absorbed doses were estimated with Monte Carlo simulations using the individual CT voxel data of phantom and patients. Further, organ segmentations were performed to obtain the dose in liver, liver parenchyma, left kidney, right kidney, aorta, and spleen. RESULTS: In the phantom study, a linear relation was observed between the radiation dose normalized by computed tomography dose index (CTDI) and CA concentrations Iconc (mg/ml) for three tube voltages; [Formula: see text] = 0.14 × Iconc + 1.02, [Formula: see text] = 0.16 × Iconc + 1.21, [Formula: see text] = 0.16 × Iconc + 1.24, and for DECT acquisition; [Formula: see text] = 0.15 × Iconc + 1.09. Similarly, a linear relation was observed between the dose increase and the organ iodine contents (R2 = 0.86 and pvalue < 0.01) in the patient study. The relative doses increased in the liver (21 ± 5%), liver parenchyma (20 ± 5%), right kidney (37 ± 7%), left kidney (39 ± 7%), aorta (34 ± 6%) and spleen (26 ± 4%). In addition, the local dose distributions changed based on patient's anatomy and physiology. CONCLUSIONS: Compared to a non-contrast scan, the organ doses increase by 30% in contrast-enhanced abdominal CT. This study suggests considering CA in dosimetry calculations, epidemiological studies, and organ dose estimations while developing new CT protocols. KEY POINTS: • The presence of contrast media increases radiation absorption in CT, and this increase is related to the iodine content in the organs. • The increased radiation absorption due to contrast media can lead to an average 30% increase in absorbed organ dose. • Iodine should be considered in CT radiation safety studies.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Estudos Retrospectivos
13.
Eur Radiol ; 31(7): 4514-4527, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409773

RESUMO

OBJECTIVES: Multicenter oncology trials increasingly include MRI examinations with apparent diffusion coefficient (ADC) quantification for lesion characterization and follow-up. However, the repeatability and reproducibility (R&R) limits above which a true change in ADC can be considered relevant are poorly defined. This study assessed these limits in a standardized whole-body (WB)-MRI protocol. METHODS: A prospective, multicenter study was performed at three centers equipped with the same 3.0-T scanners to test a WB-MRI protocol including diffusion-weighted imaging (DWI). Eight healthy volunteers per center were enrolled to undergo test and retest examinations in the same center and a third examination in another center. ADC variability was assessed in multiple organs by two readers using two-way mixed ANOVA, Bland-Altman plots, coefficient of variation (CoV), and the upper limit of the 95% CI on repeatability (RC) and reproducibility (RDC) coefficients. RESULTS: CoV of ADC was not influenced by other factors (center, reader) than the organ. Based on the upper limit of the 95% CI on RC and RDC (from both readers), a change in ADC in an individual patient must be superior to 12% (cerebrum white matter), 16% (paraspinal muscle), 22% (renal cortex), 26% (central and peripheral zones of the prostate), 29% (renal medulla), 35% (liver), 45% (spleen), 50% (posterior iliac crest), 66% (L5 vertebra), 68% (femur), and 94% (acetabulum) to be significant. CONCLUSIONS: This study proposes R&R limits above which ADC changes can be considered as a reliable quantitative endpoint to assess disease or treatment-related changes in the tissue microstructure in the setting of multicenter WB-MRI trials. KEY POINTS: • The present study showed the range of R&R of ADC in WB-MRI that may be achieved in a multicenter framework when a standardized protocol is deployed. • R&R was not influenced by the site of acquisition of DW images. • Clinically significant changes in ADC measured in a multicenter WB-MRI protocol performed with the same type of MRI scanner must be superior to 12% (cerebrum white matter), 16% (paraspinal muscle), 22% (renal cortex), 26% (central zone and peripheral zone of prostate), 29% (renal medulla), 35% (liver), 45% (spleen), 50% (posterior iliac crest), 66% (L5 vertebra), 68% (femur), and 94% (acetabulum) to be detected with a 95% confidence level.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Masculino , Estudos Prospectivos , Próstata , Reprodutibilidade dos Testes
14.
BMC Med Imaging ; 21(1): 64, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33827463

RESUMO

BACKGROUND: Four-dimensional computed tomography (4DCT) is a commonly performed examination in the management of primary hyperparathyroidism, combining three-dimensional imaging with enhancement over time as the fourth dimension. We propose a novel technique consisting of 16 different contrast phases instead of three or four different phases. The main aim of this study was to ascertain whether this protocol allows the detection of parathyroid adenomas within dose limits. Our secondary aim was to examine the enhancement of parathyroid lesions over time. METHODS: For this prospective study, we included 15 patients with primary hyperparathyroidism and a positive ultrasound prior to surgery. We performed 4DCT with 16 different phases: an unenhanced phase followed by 11 consecutive arterial phases and 4 venous phases. Continuous axial scanning centered on the thyroid was performed over a fixed 8 cm or 16 cm coverage volume after the start of contrast administration. RESULTS: In all patients, an enlarged parathyroid lesion was demonstrated, and the mean lesion size was 13.6 mm. The mean peak arterial enhancement for parathyroid lesions was 384 Hounsfield units (HU) compared to 333 HU for the normal thyroid. No significant difference could be found. The time to peak (TTP) was significantly earlier for parathyroid adenomas than for normal thyroid tissue: 30.8 s versus 32.3 s (p value 0.008). The mean slope of increase (MSI) of the enhancement curve was significantly steeper than that of normal thyroid tissue: 29.8% versus 22.2% (p value 0.012). The mean dose length product was 890.7 mGy cm with a calculated effective dose of 6.7 mSv. CONCLUSION: Our 4DCT protocol may allow better visualization of the pattern of enhancement of parathyroid lesions, as enhancement over time curves can be drawn. In this way, wash-in and wash-out of contrast in suspected lesions can be readily demonstrated. Motion artifacts are less problematic as multiple phases are available. Exposure to our proposed 4DCT technique is comparable to that for classic helical 4DCT. Careful selection of parameters (lowering kV and SNR) can help to further reduce the dose.


Assuntos
Adenoma/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias das Paratireoides/diagnóstico por imagem , Adenoma/irrigação sanguínea , Adenoma/patologia , Meios de Contraste/administração & dosagem , Feminino , Humanos , Hiperparatireoidismo Primário/sangue , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço , Glândulas Paratireoides/irrigação sanguínea , Glândulas Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/irrigação sanguínea , Neoplasias das Paratireoides/patologia , Estudos Prospectivos , Fatores de Tempo , Carga Tumoral
15.
Magn Reson Med ; 83(5): 1851-1862, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31643114

RESUMO

PURPOSE: To improve multi-atlas segmentation of the skeleton from whole-body MRI. In particular, we study the effect of employing the atlas segmentations to iteratively mask tissues outside of the region of interest to improve the atlas alignment and subsequent segmentation. METHODS: An improved atlas registration scheme is proposed. Starting from a suitable initial alignment, the alignment is refined by introducing additional stages of deformable registration during which the image sampling is limited to the dilated atlas segmentation label mask. The performance of the method was demonstrated using leave-one-out cross-validation using atlases of 10 whole-body 3D-T1 images of prostate cancer patients with bone metastases and healthy male volunteers, and compared to existing state of the art. Both registration accuracy and resulting segmentation quality, using four commonly used label fusion strategies, were evaluated. RESULTS: The proposed method showed significant improvement in registration and segmentation accuracy with respect to the state of the art for all validation criteria and label fusion strategies, resulting in a Dice coefficient of 0.887 (STEPS label fusion). The average Dice coefficient for the multi-atlas segmentation showed over 11% improvement with a decrease of false positive rate from 28.3% to 13.2%. For this application, repeated application of the background masking did not lead to significant improvement of the segmentation result. CONCLUSIONS: A registration strategy, relying on the use of atlas segmentations as mask during image registration was proposed and evaluated for multi-atlas segmentation of whole-body MRI. The approach significantly improved registration and final segmentation accuracy and may be applicable to other structures of interest.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Algoritmos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Esqueleto
16.
Pol J Radiol ; 85: e32-e38, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32180852

RESUMO

Intra-abdominal fat is abundantly present in both the peritoneum and retroperitoneum. Fat necrosis or inflammation are common findings in abdominal imaging. The most common pathologies that we encounter are epiploic appendagitis, omental infarction, mesenteric panniculitis, and encapsulated fat necrosis. Less common entities that can occur are pancreatic saponification, heterotopic mesenteric ossification, and pseudolipoma of the capsule of Glisson. These entities can mimic more urgent pathologies such as appendicitis, diverticulitis, or malignancies.

17.
AJR Am J Roentgenol ; 213(2): 404-409, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31012759

RESUMO

OBJECTIVE. The purpose of this study is to investigate the contributing effect of contrast media (CM) iodine dose on radiation-induced DNA damage in blood lymphocytes during a cardiac CT scan. MATERIALS AND METHODS. The minipigs were exposed 12 times in total to a fixed cardiac CT scan protocol. An unenhanced and two CM injection protocols were considered, the latter with 50% saline diluted (160 mg I/mL) and standard iodixanol. Blood samples were collected before and after CT, and radiation-induced DNA double-strand breaks were assessed using γ-H2AX (H2A histone family member X) immunofluorescent staining of the blood lymphocytes. Significant differences in foci numbers were investigated with an independent sample t test. In addition, a numeric dosimetry model was applied that simulates the cardiac CT scan, with the heart represented by a blood volume containing a mixture of six iodine concentrations (0, 10, 20, 30, 40, and 50 mg I/mL). RESULTS. Compared with the unenhanced (0 mg I/mL) protocol, the number of γ-H2AX foci per cell increased significantly (p < 0.038), by 56.1% for the reduced iodine dose (160 mg I/mL) and by 141.1% for the standard iodine dose (320 mg I/mL) protocols. These in vivo results are confirmed by the dosimetry simulation model, in which 78.8% and 133.7% increases in locally absorbed blood dose in the left ventricle were observed for the reduced and standard iodine dose protocols, respectively. CONCLUSION. Administration of CM during a cardiac CT examination significantly increases radiation-induced DNA damage in blood lymphocytes. Moreover, a lower CM iodine dose results in a reduced level of DNA damage, at constant radiation exposure.


Assuntos
Meios de Contraste/efeitos adversos , Dano ao DNA , Cardiopatias/diagnóstico por imagem , Lesões por Radiação/sangue , Lesões por Radiação/etiologia , Tomografia Computadorizada por Raios X/efeitos adversos , Ácidos Tri-Iodobenzoicos/efeitos adversos , Animais , Método de Monte Carlo , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Suínos , Porco Miniatura
18.
Artigo em Inglês | MEDLINE | ID: mdl-31384339

RESUMO

BACKGROUND: Von Hippel-Lindau (VHL) disease is an autosomal dominantly inherited tumor syndrome. Affected patients develop central nervous system hemangioblastomas and abdominal tumors, among other lesions. Patients undergo an annual clinical screening program including separate magnetic resonance imaging (MRI) of the brain, whole spine and abdomen. Consequently, patients are repeatedly subjected to time-consuming and expensive MRI scans, performed with cumulative Gadolinium injections. We report our experience with a 35-min whole body MRI screening protocol, specifically designed for detection of VHL-associated lesions. METHODS: We designed an MRI protocol dedicated to the typical characteristics of VHL-associated lesions in different imaging sequences, within the time frame of 35 min. Blank imaging of the abdomen is carried out first, followed by abdominal sequences with Gadolinium contrast. Next, the full spine is examined, followed by imaging of the brain. A single dose of contrast used for abdominal imaging is sufficient for further highlighting of spine- and brain lesions, thus limiting the Gadolinium dosage. We used 1.5 Tesla equipment, dealing with fewer artifacts compared to a 3 Tesla system for spine- and abdominal imaging, while preserving acceptable quality for central nervous system images. In addition, imaging on a 1.5 Tesla scanner is slightly faster. RESULTS: From January 2016 to November 2018, we performed 38 whole body screening MRIs in 18 VHL patients; looking for the most common types of VHL lesions in the abdomen, spine, and brain, both for new lesions and follow-up. The one-step approach MRI examinations lead to 6 surgical interventions for clinically significant or symptomatic hemangioblastomas in the brain and spine. One renal cell carcinoma was treated with radiofrequency ablation. In comparison with previous conventional MRI scans of the same patients, all lesions were visible with the focused protocol. CONCLUSIONS: Annual screening in VHL disease can be done in a rapid, safe and sensitive way by using a dedicated whole body MRI protocol; saving MRI examination time and limiting Gadolinium dose.

19.
Eur Heart J ; 39(41): 3689-3698, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30312411

RESUMO

Aims: Coronary computed tomography angiography (CTA) has emerged as a non-invasive diagnostic method for patients with suspected coronary artery disease, but its usefulness in patients with complex coronary artery disease remains to be investigated. The present study sought to determine the agreement between separate heart teams on treatment decision-making based on either coronary CTA or conventional angiography. Methods and results: Separate heart teams composed of an interventional cardiologist, a cardiac surgeon, and a radiologist were randomized to assess the coronary artery disease with either coronary CTA or conventional angiography in patients with de novo left main or three-vessel coronary artery disease. Each heart team, blinded for the other imaging modality, quantified the anatomical complexity using the SYNTAX score and integrated clinical information using the SYNTAX Score II to provide a treatment recommendations based on mortality prediction at 4 years: coronary artery bypass grafting (CABG), percutaneous coronary intervention (PCI), or equipoise between CABG and PCI. The primary endpoint was the agreement between heart teams on the revascularization strategy. The secondary endpoint was the impact of fractional flow reserve derived from coronary CTA (FFRCT) on treatment decision and procedural planning. Overall, 223 patients were included. A treatment recommendation of CABG was made in 28% of the cases with coronary CTA and in 26% with conventional angiography. The agreement concerning treatment decision between coronary CTA and conventional angiography was high (Cohen's kappa 0.82, 95% confidence interval 0.74-0.91). The heart teams agreed on the coronary segments to be revascularized in 80% of the cases. FFRCT was available for 869/1108 lesions (196/223 patients). Fractional flow reserve derived from coronary CTA changed the treatment decision in 7% of the patients. Conclusion: In patients with left main or three-vessel coronary artery disease, a heart team treatment decision-making based on coronary CTA showed high agreement with the decision derived from conventional coronary angiography suggesting the potential feasibility of a treatment decision-making and planning based solely on this non-invasive imaging modality and clinical information. Trial registration number: NCT02813473.


Assuntos
Tomada de Decisão Clínica/métodos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Idoso , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea
20.
Surg Radiol Anat ; 41(12): 1445-1449, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31630237

RESUMO

PURPOSE: To assess normal distribution of fluid in the tendon sheaths of the ankle. METHODS: 21 healthy volunteers were evaluated. Bilateral ankle MRI was performed on a 3T unit with PD-weighted images with fat saturation. The images were interpreted by two radiologists separately, and the short-axis dimension of fluid amount was measured. Bland-Altman plots and correlation plots were used to assess consistency between readers. RESULTS: There were 13 men and 8 women. The mean age was 24.7 years. Fluid in the retromalleolar part of the peroneus longus was seen in three ankles of three volunteers and in the inframalleolar part in three ankles of three volunteers. Fluid in the retromalleolar part of the peroneus brevis was seen in four ankles of three volunteers and in the inframalleolar part in three ankles of two volunteers. Fluid in the retromalleolar part of the tibialis posterior was seen in 37 ankles of 20 volunteers and in the inframalleolar part in 38 ankles of 21 volunteers Fluid in the retromalleolar part of the flexor digitorum was seen in 14 ankles of eight volunteers and in the inframalleolar part in 11 ankles of eight volunteers Fluid in the retromalleolar part of the flexor hallucis longus was seen in 23 ankles of 16 volunteers and in the inframalleolar part in 17 ankles of 11 volunteers. CONCLUSION: Fluid is common in the retro- and inframalleolar parts of the medial tendons. Fluid is virtually absent in the peroneal tendons and anterior tendon sheaths in normal volunteers.


Assuntos
Articulação do Tornozelo/anatomia & histologia , Líquido Sinovial/diagnóstico por imagem , Tendões/anatomia & histologia , Adulto , Articulação do Tornozelo/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Masculino , Tendões/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA