Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Epilepsia ; 65(2): 378-388, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38036450

RESUMO

OBJECTIVE: Home monitoring of 3-Hz spike-wave discharges (SWDs) in patients with refractory absence epilepsy could improve clinical care by replacing the inaccurate seizure diary with objective counts. We investigated the use and performance of the Sensor Dot (Byteflies) wearable in persons with absence epilepsy in their home environment. METHODS: Thirteen participants (median age = 22 years, 11 female) were enrolled at the university hospitals of Leuven and Freiburg. At home, participants had to attach the Sensor Dot and behind-the-ear electrodes to record two-channel electroencephalogram (EEG), accelerometry, and gyroscope data. Ground truth annotations were created during a visual review of the full Sensor Dot recording. Generalized SWDs were annotated if they were 3 Hz and at least 3 s on EEG. Potential 3-Hz SWDs were flagged by an automated seizure detection algorithm, (1) using only EEG and (2) with an additional postprocessing step using accelerometer and gyroscope to discard motion artifacts. Afterward, two readers (W.V.P. and L.S.) reviewed algorithm-labeled segments and annotated true positive detections. Sensitivity, precision, and F1 score were calculated. Patients had to keep a seizure diary and complete questionnaires about their experiences. RESULTS: Total recording time was 394 h 42 min. Overall, 234 SWDs were captured in 11 of 13 participants. Review of the unimodal algorithm-labeled recordings resulted in a mean sensitivity of .84, precision of .93, and F1 score of .89. Visual review of the multimodal algorithm-labeled segments resulted in a similar F1 score and shorter review time due to fewer false positive labels. Participants reported that the device was comfortable and that they would be willing to wear it on demand of their neurologist, for a maximum of 1 week or with intermediate breaks. SIGNIFICANCE: The Sensor Dot improved seizure documentation at home, relative to patient self-reporting. Additional benefits were the short review time and the patients' device acceptance due to user-friendliness and comfortability.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia Tipo Ausência , Dispositivos Eletrônicos Vestíveis , Adulto , Feminino , Humanos , Adulto Jovem , Eletrodos , Eletroencefalografia/métodos , Convulsões/diagnóstico , Masculino
2.
Brain Topogr ; 37(3): 461-474, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37823945

RESUMO

Preterm neonates are at risk of long-term neurodevelopmental impairments due to disruption of natural brain development. Electroencephalography (EEG) analysis can provide insights into brain development of preterm neonates. This study aims to explore the use of microstate (MS) analysis to evaluate global brain dynamics changes during maturation in preterm neonates with normal neurodevelopmental outcome.The dataset included 135 EEGs obtained from 48 neonates at varying postmenstrual ages (26.4 to 47.7 weeks), divided into four age groups. For each recording we extracted a 5-minute epoch during quiet sleep (QS) and during non-quiet sleep (NQS), resulting in eight groups (4 age group x 2 sleep states). We compared MS maps and corresponding (map-specific) MS metrics across groups using group-level maps. Additionally, we investigated individual map metrics.Four group-level MS maps accounted for approximately 70% of the global variance and showed non-random syntax. MS topographies and transitions changed significantly when neonates reached 37 weeks. For both sleep states and all MS maps, MS duration decreased and occurrence increased with age. The same relationships were found using individual maps, showing strong correlations (Pearson coefficients up to 0.74) between individual map metrics and post-menstrual age. Moreover, the Hurst exponent of the individual MS sequence decreased with age.The observed changes in MS metrics with age might reflect the development of the preterm brain, which is characterized by formation of neural networks. Therefore, MS analysis is a promising tool for monitoring preterm neonatal brain maturation, while our study can serve as a valuable reference for investigating EEGs of neonates with abnormal neurodevelopmental outcomes.


Assuntos
Encéfalo , Eletroencefalografia , Recém-Nascido , Humanos , Eletroencefalografia/métodos , Sono , Benchmarking , Idioma
3.
Epilepsy Behav ; 158: 109917, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38924968

RESUMO

PURPOSE: Seizures are characterized by periictal autonomic changes. Wearable devices could help improve our understanding of these phenomena through long-term monitoring. In this study, we used wearable electrocardiogram (ECG) data to evaluate differences between temporal and extratemporal focal impaired awareness (FIA) seizures monitored in the hospital and at home. We assessed periictal heart rate, respiratory rate, heart rate variability (HRV), and respiratory sinus arrhythmia (RSA). METHODS: We extracted ECG signals across three time points - five minutes baseline and preictal, ten minutes postictal - and the seizure duration. After automatic Rpeak selection, we calculated the heart rate and estimated the respiratory rate using the ECG-derived respiration methodology. HRV was calculated in both time and frequency domains. To evaluate the influence of other modulators on the HRV after removing the respiratory influences, we recalculated the residual power in the high-frequency (HF) and low-frequency (LF) bands using orthogonal subspace projections. Finally, 5-minute and 30-second (ultra-short) ECG segments were used to calculate RSA using three different methods. Seizures from temporal and extratemporal origins were compared using mixed-effects models and estimated marginal means. RESULTS: The mean preictal heart rate was 69.95 bpm (95 % CI 65.6 - 74.3), and it increased to 82 bpm, 95 % CI (77.51 - 86.47) and 84.11 bpm, 95 % CI (76.9 - 89.5) during the ictal and postictal periods. Preictal, ictal and postictal respiratory rates were 16.1 (95 % CI 15.2 - 17.1), 14.8 (95 % CI 13.4 - 16.2) and 15.1 (95 % CI 14 - 16.2), showing not statistically significant bradypnea. HRV analysis found a higher baseline power in the LF band, which was still significantly higher after removing the respiratory influences. Postictally, we found decreased power in the HF band and the respiratory influences in both frequency bands. The RSA analysis with the new methods confirmed the lower cardiorespiratory interaction during the postictal period. Additionally, using ultra-short ECG segments, we found that RSA decreases before the electroclinical seizure onset. No differences were observed in the studied parameters between temporal and extratemporal seizures. CONCLUSIONS: We found significant increases in the ictal and postictal heart rates and lower respiratory rates. Isolating the respiratory influences on the HRV showed a postictal reduction of respiratory modulations on both LF and HF bands, suggesting a central role of respiratory influences in the periictal HRV, unlike the baseline measurements. We found a reduced cardiorespiratory interaction during the periictal period using other RSA methods, suggesting a blockade in vagal efferences before the electroclinical onset. These findings highlight the importance of respiratory influences in cardiac dynamics during seizures and emphasize the need to longitudinally assess HRV and RSA to gain insights into long-term autonomic dysregulation.

4.
Thorax ; 78(10): 983-989, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37012070

RESUMO

RATIONALE: Estimating the causal effect of an intervention at individual level, also called individual treatment effect (ITE), may help in identifying response prior to the intervention. OBJECTIVES: We aimed to develop machine learning (ML) models which estimate ITE of an intervention using data from randomised controlled trials and illustrate this approach with prediction of ITE on annual chronic obstructive pulmonary disease (COPD) exacerbation rates. METHODS: We used data from 8151 patients with COPD of the Study to Understand Mortality and MorbidITy in COPD (SUMMIT) trial (NCT01313676) to address the ITE of fluticasone furoate/vilanterol (FF/VI) versus control (placebo) on exacerbation rate and developed a novel metric, Q-score, for assessing the power of causal inference models. We then validated the methodology on 5990 subjects from the InforMing the PAthway of COPD Treatment (IMPACT) trial (NCT02164513) to estimate the ITE of FF/umeclidinium/VI (FF/UMEC/VI) versus UMEC/VI on exacerbation rate. We used Causal Forest as causal inference model. RESULTS: In SUMMIT, Causal Forest was optimised on the training set (n=5705) and tested on 2446 subjects (Q-score 0.61). In IMPACT, Causal Forest was optimised on 4193 subjects in the training set and tested on 1797 individuals (Q-score 0.21). In both trials, the quantiles of patients with the strongest ITE consistently demonstrated the largest reductions in observed exacerbations rates (0.54 and 0.53, p<0.001). Poor lung function and blood eosinophils, respectively, were the strongest predictors of ITE. CONCLUSIONS: This study shows that ML models for causal inference can be used to identify individual response to different COPD treatments and highlight treatment traits. Such models could become clinically useful tools for individual treatment decisions in COPD.


Assuntos
Pulmão , Doença Pulmonar Obstrutiva Crônica , Humanos , Administração por Inalação , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Androstadienos/uso terapêutico , Androstadienos/farmacologia , Álcoois Benzílicos/uso terapêutico , Álcoois Benzílicos/farmacologia , Clorobenzenos/uso terapêutico , Clorobenzenos/farmacologia , Broncodilatadores/uso terapêutico , Combinação de Medicamentos , Método Duplo-Cego , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Respir Res ; 24(1): 20, 2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36658542

RESUMO

BACKGROUND: Parameters from maximal expiratory flow-volume curves (MEFVC) have been linked to CT-based parameters of COPD. However, the association between MEFVC shape and phenotypes like emphysema, small airways disease (SAD) and bronchial wall thickening (BWT) has not been investigated. RESEARCH QUESTION: We analyzed if the shape of MEFVC can be linked to CT-determined emphysema, SAD and BWT in a large cohort of COPDGene participants. STUDY DESIGN AND METHODS: In the COPDGene cohort, we used principal component analysis (PCA) to extract patterns from MEFVC shape and performed multiple linear regression to assess the association of these patterns with CT parameters over the COPD spectrum, in mild and moderate-severe COPD. RESULTS: Over the entire spectrum, in mild and moderate-severe COPD, principal components of MEFVC were important predictors for the continuous CT parameters. Their contribution to the prediction of emphysema diminished when classical pulmonary function test parameters were added. For SAD, the components remained very strong predictors. The adjusted R2 was higher in moderate-severe COPD, while in mild COPD, the adjusted R2 for all CT outcomes was low; 0.28 for emphysema, 0.21 for SAD and 0.19 for BWT. INTERPRETATION: The shape of the maximal expiratory flow-volume curve as analyzed with PCA is not an appropriate screening tool for early disease phenotypes identified by CT scan. However, it contributes to assessing emphysema and SAD in moderate-severe COPD.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Análise de Componente Principal , Fumar , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/genética , Espirometria , Fenótipo , Volume Expiratório Forçado
6.
Epilepsia ; 64(4): 937-950, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36681896

RESUMO

OBJECTIVE: The aim is to report the performance of an electroencephalogram (EEG) seizure-detector algorithm on data obtained with a wearable device (WD) in patients with focal refractory epilepsy and their experience. METHODS: Patients used a WD, the Sensor Dot (SD), to measure two channels of EEG using dry electrode patches during presurgical evaluation and at home for up to 8 months. An automated seizure detection algorithm flagged EEG regions with possible seizures, which we reviewed to evaluate the algorithm's diagnostic yield. In addition, we collected data on usability, side effects, and patient satisfaction with an electronic seizure diary application (Helpilepsy). RESULTS: Sixteen inpatients used the SD for up to 5 days and had 21 seizures. Sixteen outpatients used the device for up to 8 months and reported 101 focal impaired awareness seizures during the periods selected for analysis. Focal seizure detection sensitivity based on behind-the-ear EEG was 52% in inpatients and 23% in outpatients. False detections/h, positive predictive value (PPV), and F1 scores were 7.13%, .11%, and .002% for inpatients and 7.77%, .04%, and .001% for outpatients. Artifacts and low signal quality contributed to poor performance metrics. The seizure detector identified 19 nonreported seizures during sleep, when the signal quality was better. Regarding patients' experience, the likelihood of using the device at 6 months was 62%, and side effects were the main reason for dropping out. Finally, daily and monthly questionnaire completion rates were 33% and 65%, respectively. SIGNIFICANCE: Focal seizure detection sensitivity based on behind-the-ear EEG was 52% in inpatients and 23% in outpatients, with high false alarm rates and low PPV and F1 scores. This unobtrusive wearable seizure detection device was well received but had side effects. The current workflow and low performance limit its implementation in clinical practice. We suggest different steps to improve these performance metrics and patient experience.


Assuntos
Epilepsias Parciais , Dispositivos Eletrônicos Vestíveis , Humanos , Epilepsias Parciais/diagnóstico , Convulsões/diagnóstico , Algoritmos , Eletroencefalografia , Hospitais
7.
J Am Soc Nephrol ; 33(11): 2026-2039, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36316096

RESUMO

BACKGROUND: No validated system currently exists to realistically characterize the chronic pathology of kidney transplants that represents the dynamic disease process and spectrum of disease severity. We sought to develop and validate a tool to describe chronicity and severity of renal allograft disease and integrate it with the evaluation of disease activity. METHODS: The training cohort included 3549 kidney transplant biopsies from an observational cohort of 937 recipients. We reweighted the chronic histologic lesions according to their time-dependent association with graft failure, and performed consensus k-means clustering analysis. Total chronicity was calculated as the sum of the weighted chronic lesion scores, scaled to the unit interval. RESULTS: We identified four chronic clusters associated with graft outcome, based on the proportion of ambiguous clustering. The two clusters with the worst survival outcome were determined by interstitial fibrosis and tubular atrophy (IFTA) and by transplant glomerulopathy. The chronic clusters partially overlapped with the existing Banff IFTA classification (adjusted Rand index, 0.35) and were distributed independently of the acute lesions. Total chronicity strongly associated with graft failure (hazard ratio [HR], 8.33; 95% confidence interval [CI], 5.94 to 10.88; P<0.001), independent of the total activity scores (HR, 5.01; 95% CI, 2.83 to 7.00; P<0.001). These results were validated on an external cohort of 4031 biopsies from 2054 kidney transplant recipients. CONCLUSIONS: The evaluation of total chronicity provides information on kidney transplant pathology that complements the estimation of disease activity from acute lesion scores. Use of the data-driven algorithm used in this study, called RejectClass, may provide a holistic and quantitative assessment of kidney transplant injury phenotypes and severity.


Assuntos
Nefropatias , Transplante de Rim , Humanos , Transplante de Rim/métodos , Sobrevivência de Enxerto , Rejeição de Enxerto/patologia , Rim/patologia , Biópsia , Nefropatias/patologia , Proteínas do Sistema Complemento , Aloenxertos/patologia , Fenótipo
8.
Psychol Med ; 52(13): 2741-2750, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-33431090

RESUMO

BACKGROUND: Sleep disruption is a common precursor to deterioration and relapse in people living with psychotic disorders. Understanding the temporal relationship between sleep and psychopathology is important for identifying and developing interventions which target key variables that contribute to relapse. METHODS: We used a purpose-built digital platform to sample self-reported sleep and psychopathology variables over 1 year, in 36 individuals with schizophrenia. Once-daily measures of sleep duration and sleep quality, and fluctuations in psychopathology (positive and negative affect, cognition and psychotic symptoms) were captured. We examined the temporal relationship between these variables using the Differential Time-Varying Effect (DTVEM) hybrid exploratory-confirmatory model. RESULTS: Poorer sleep quality and shorter sleep duration maximally predicted deterioration in psychosis symptoms over the subsequent 1-8 and 1-12 days, respectively. These relationships were also mediated by negative affect and cognitive symptoms. Psychopathology variables also predicted sleep quality, but not sleep duration, and the effect sizes were smaller and of shorter lag duration. CONCLUSIONS: Reduced sleep duration and poorer sleep quality anticipate the exacerbation of psychotic symptoms by approximately 1-2 weeks, and negative affect and cognitive symptoms mediate this relationship. We also observed a reciprocal relationship that was of shorter duration and smaller magnitude. Sleep disturbance may play a causal role in symptom exacerbation and relapse, and represents an important and tractable target for intervention. It warrants greater attention as an early warning sign of deterioration, and low-burden, user-friendly digital tools may play a role in its early detection.


Assuntos
Transtornos Psicóticos , Esquizofrenia , Distúrbios do Início e da Manutenção do Sono , Transtornos do Sono-Vigília , Humanos , Estudos de Amostragem , Transtornos Psicóticos/psicologia , Esquizofrenia/diagnóstico , Psicopatologia , Doença Crônica , Recidiva
9.
Adv Exp Med Biol ; 1395: 183-187, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36527635

RESUMO

Brain monitoring is important in neonates with asphyxia in order to assess the severity of hypoxic ischaemic encephalopathy (HIE) and identify neonates at risk of adverse neurodevelopmental outcome. Previous studies suggest that neurovascular coupling (NVC), quantified as the interaction between electroencephalography (EEG) and near-infrared spectroscopy (NIRS)-derived regional cerebral oxygen saturation (rSO2) is a promising biomarker for HIE severity and outcome. In this study, we explore how wavelet coherence can be used to assess NVC. Wavelet coherence was computed in 18 neonates undergoing therapeutic hypothermia in the first 3 days of life, with varying HIE severities (mild, moderate, severe). We compared two pre-processing methods of the EEG prior to wavelet computation: amplitude integrated EEG (aEEG) and EEG bandpower. Furthermore, we proposed average real coherence as a biomarker for NVC. Our results indicate that NVC as assessed by wavelet coherence between EEG bandpower and rSO2 can be a valuable biomarker for HIE severity in neonates with peripartal asphyxia. More specifically, average real coherence in a very low frequency range (0.21-0.83 mHz) tends to be high (positive) in neonates with mild HIE, low (positive) in neonates with moderate HIE, and negative in neonates with severe HIE. Further investigation in a larger patient cohort is needed to validate our findings.


Assuntos
Hipotermia Induzida , Hipóxia-Isquemia Encefálica , Acoplamento Neurovascular , Recém-Nascido , Humanos , Asfixia/terapia , Hipóxia-Isquemia Encefálica/diagnóstico , Hipóxia-Isquemia Encefálica/terapia , Hipotermia Induzida/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Eletroencefalografia/métodos
10.
J Am Soc Nephrol ; 32(5): 1084-1096, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33687976

RESUMO

BACKGROUND: Over the past decades, an international group of experts iteratively developed a consensus classification of kidney transplant rejection phenotypes, known as the Banff classification. Data-driven clustering of kidney transplant histologic data could simplify the complex and discretionary rules of the Banff classification, while improving the association with graft failure. METHODS: The data consisted of a training set of 3510 kidney-transplant biopsies from an observational cohort of 936 recipients. Independent validation of the results was performed on an external set of 3835 biopsies from 1989 patients. On the basis of acute histologic lesion scores and the presence of donor-specific HLA antibodies, stable clustering was achieved on the basis of a consensus of 400 different clustering partitions. Additional information on kidney-transplant failure was introduced with a weighted Euclidean distance. RESULTS: Based on the proportion of ambiguous clustering, six clinically meaningful cluster phenotypes were identified. There was significant overlap with the existing Banff classification (adjusted rand index, 0.48). However, the data-driven approach eliminated intermediate and mixed phenotypes and created acute rejection clusters that are each significantly associated with graft failure. Finally, a novel visualization tool presents disease phenotypes and severity in a continuous manner, as a complement to the discrete clusters. CONCLUSIONS: A semisupervised clustering approach for the identification of clinically meaningful novel phenotypes of kidney transplant rejection has been developed and validated. The approach has the potential to offer a more quantitative evaluation of rejection subtypes and severity, especially in situations in which the current histologic categorization is ambiguous.


Assuntos
Rejeição de Enxerto/patologia , Nefropatias/patologia , Nefropatias/cirurgia , Transplante de Rim/estatística & dados numéricos , Doença Aguda , Adulto , Idoso , Análise por Conglomerados , Estudos de Coortes , Feminino , Rejeição de Enxerto/epidemiologia , Sobrevivência de Enxerto , Humanos , Nefropatias/mortalidade , Transplante de Rim/efeitos adversos , Transplante de Rim/mortalidade , Masculino , Pessoa de Meia-Idade , Fenótipo , Reprodutibilidade dos Testes
11.
Sensors (Basel) ; 22(19)2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36236241

RESUMO

Respiratory rate (RR) is a clinically important predictor of cardio-respiratory deteriorations. The mainstay of clinical measurement comprises the manual counting of chest movements, which is variable between clinicians and limited to sporadic readings. Emerging solutions are limited by poor adherence and acceptability or are not clinically validated. Albus HomeTM is a contactless and automated bedside system for nocturnal respiratory monitoring that overcomes these limitations. This study aimed to validate the accuracy of Albus Home compared to gold standards in real-world sleeping environments. Participants undertook overnight monitoring simultaneously using Albus Home and gold-standard polygraphy with thoraco-abdominal respiratory effort belts (SomnomedicsEU). Reference RR readings were obtained by clinician-count of polygraphy data. For both the Albus system and reference, RRs were measured in 30-s segments, reported as breaths/minute, and compared. Accuracy was defined as the percentage of RRs from the Albus system within ±2 breaths/minute of reference counts. Across a diverse validation set of 32 participants, the mean accuracy exceeded 98% and was maintained across different participant characteristics. In a Bland-Altman analysis, Albus RRs had strong agreement with reference mean differences and the limits of agreement of -0.4 and ±1.2 breaths/minute, respectively. Albus Home is a contactless yet accurate system for automated respiratory monitoring. Validated against gold -standard methods, it enables long-term, reliable nocturnal monitoring without patient burden.


Assuntos
Respiração , Taxa Respiratória , Humanos , Monitorização Fisiológica/métodos
12.
Neuroimage ; 226: 117508, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33157263

RESUMO

Along the pathway from behavioral symptoms to the development of psychotic disorders sits the multivariate mediating brain. The functional organization and structural topography of large-scale multivariate neural mediators among patients with brain disorders, however, are not well understood. Here, we design a high-dimensional brain-wide functional mediation framework to investigate brain regions that intermediate between baseline behavioral symptoms and future conversion to full psychosis among individuals at clinical high risk (CHR). Using resting-state functional magnetic resonance imaging (fMRI) data from 263 CHR subjects, we extract an α brain atlas and a ß brain atlas: the former underlines brain areas associated with prodromal symptoms and the latter highlights brain areas associated with disease onset. In parallel, we identify and separate mediators that potentially positively and negatively mediate symptoms and psychosis, respectively, and quantify the effect of each neural mediator on disease development. Taken together, these results paint a brain-wide picture of neural markers that are potentially mediating behavioral symptoms and the development of psychotic disorders; additionally, they underscore a statistical framework that is useful to uncover large-scale intermediating variables in a regulatory biological system.


Assuntos
Sintomas Comportamentais/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Sintomas Prodrômicos , Transtornos Psicóticos/diagnóstico por imagem , Sintomas Comportamentais/fisiopatologia , Mapeamento Encefálico/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Análise de Mediação , Transtornos Psicóticos/fisiopatologia , Adulto Jovem
13.
Epilepsia ; 62(10): 2333-2343, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34240748

RESUMO

OBJECTIVE: Wearable seizure detection devices could provide more reliable seizure documentation outside the hospital compared to seizure self-reporting by patients, which is the current standard. Previously, during the SeizeIT1 project, we studied seizure detection based on behind-the-ear electroencephalography (EEG). However, the obtained sensitivities were too low for practical use, because not all seizures are associated with typical ictal EEG patterns. Therefore, in this paper, we aim to develop a multimodal automated seizure detection algorithm integrating behind-the-ear EEG and electrocardiography (ECG) for detecting focal seizures. In this framework, we quantified the added value of ECG to behind-the-ear EEG. METHODS: This study analyzed three multicenter databases consisting of 135 patients having focal epilepsy and a total of 896 seizures. A patient-specific multimodal automated seizure detection algorithm was developed using behind-the-ear/temporal EEG and single-lead ECG. The EEG and ECG data were processed separately using machine learning methods. A late integration approach was applied for fusing those predictions. RESULTS: The multimodal algorithm outperformed the EEG-based algorithm in two of three databases, with an increase of 11% and 8% in sensitivity for the same false alarm rate. SIGNIFICANCE: ECG can be of added value to an EEG-based seizure detection algorithm using only behind-the-ear/temporal lobe electrodes for patients with focal epilepsy.


Assuntos
Epilepsias Parciais , Dispositivos Eletrônicos Vestíveis , Algoritmos , Eletrocardiografia , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Humanos , Convulsões/diagnóstico
14.
Epilepsia ; 62(11): 2741-2752, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34490891

RESUMO

OBJECTIVE: Patients with absence epilepsy sensitivity <10% of their absences. The clinical gold standard to assess absence epilepsy is a 24-h electroencephalographic (EEG) recording, which is expensive, obtrusive, and time-consuming to review. We aimed to (1) investigate the performance of an unobtrusive, two-channel behind-the-ear EEG-based wearable, the Sensor Dot (SD), to detect typical absences in adults and children; and (2) develop a sensitive patient-specific absence seizure detection algorithm to reduce the review time of the recordings. METHODS: We recruited 12 patients (median age = 21 years, range = 8-50; seven female) who were admitted to the epilepsy monitoring units of University Hospitals Leuven for a 24-h 25-channel video-EEG recording to assess their refractory typical absences. Four additional behind-the-ear electrodes were attached for concomitant recording with the SD. Typical absences were defined as 3-Hz spike-and-wave discharges on EEG, lasting 3 s or longer. Seizures on SD were blindly annotated on the full recording and on the algorithm-labeled file and consequently compared to 25-channel EEG annotations. Patients or caregivers were asked to keep a seizure diary. Performance of the SD and seizure diary were measured using the F1 score. RESULTS: We concomitantly recorded 284 absences on video-EEG and SD. Our absence detection algorithm had a sensitivity of .983 and false positives per hour rate of .9138. Blind reading of full SD data resulted in sensitivity of .81, precision of .89, and F1 score of .73, whereas review of the algorithm-labeled files resulted in scores of .83, .89, and .87, respectively. Patient self-reporting gave sensitivity of .08, precision of 1.00, and F1 score of .15. SIGNIFICANCE: Using the wearable SD, epileptologists were able to reliably detect typical absence seizures. Our automated absence detection algorithm reduced the review time of a 24-h recording from 1-2 h to around 5-10 min.


Assuntos
Epilepsia Tipo Ausência , Dispositivos Eletrônicos Vestíveis , Adolescente , Adulto , Algoritmos , Criança , Eletroencefalografia/métodos , Epilepsia Tipo Ausência/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Convulsões/diagnóstico , Adulto Jovem
15.
Sensors (Basel) ; 21(18)2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34577518

RESUMO

Ischemic heart disease is the highest cause of mortality globally each year. This puts a massive strain not only on the lives of those affected, but also on the public healthcare systems. To understand the dynamics of the healthy and unhealthy heart, doctors commonly use an electrocardiogram (ECG) and blood pressure (BP) readings. These methods are often quite invasive, particularly when continuous arterial blood pressure (ABP) readings are taken, and not to mention very costly. Using machine learning methods, we develop a framework capable of inferring ABP from a single optical photoplethysmogram (PPG) sensor alone. We train our framework across distributed models and data sources to mimic a large-scale distributed collaborative learning experiment that could be implemented across low-cost wearables. Our time-series-to-time-series generative adversarial network (T2TGAN) is capable of high-quality continuous ABP generation from a PPG signal with a mean error of 2.95 mmHg and a standard deviation of 19.33 mmHg when estimating mean arterial pressure on a previously unseen, noisy, independent dataset. To our knowledge, this framework is the first example of a GAN capable of continuous ABP generation from an input PPG signal that also uses a federated learning methodology.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Pressão Sanguínea , Eletrocardiografia , Humanos , Hipertensão/diagnóstico , Fotopletismografia
16.
Sensors (Basel) ; 21(4)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33557034

RESUMO

Wearable technology will become available and allow prolonged electroencephalography (EEG) monitoring in the home environment of patients with epilepsy. Neurologists analyse the EEG visually and annotate all seizures, which patients often under-report. Visual analysis of a 24-h EEG recording typically takes one to two hours. Reliable automated seizure detection algorithms will be crucial to reduce this analysis. We investigated such algorithms on a dataset of behind-the-ear EEG measurements. Our first aim was to develop a methodology where part of the data is deferred to a human expert, who performs perfectly, with the goal of obtaining an (almost) perfect detection sensitivity (DS). Prediction confidences are determined by temperature scaling of the classification model outputs and trust scores. A DS of approximately 90% (99%) can be achieved when deferring around 10% (40%) of the data. Perfect DS can be achieved when deferring 50% of the data. Our second contribution demonstrates that a common modelling strategy, where predictions from several short EEG segments are combined to obtain a final prediction, can be improved by filtering out untrustworthy segments with low trust scores. The false detection rate shows a relative decrease between 21% and 43%, and the DS shows a small increase or decrease.


Assuntos
Epilepsia , Confiança , Algoritmos , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Convulsões/diagnóstico , Sensibilidade e Especificidade
17.
J Sleep Res ; 28(1): e12753, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30198095

RESUMO

It is often stated that sleep deprivation is on the rise, with work suggested as a main cause. However, the evidence for increasing sleep deprivation comes from surveys using habitual sleep questions. An alternative source of information regarding sleep behaviour is time-use studies. This paper investigates changes in sleep time in the UK using the two British time-use studies that allow measuring "time in bed not asleep" separately from "actual sleep time". Based upon the studies presented here, people in the UK sleep today 43 min more than they did in the 1970s because they go to bed earlier (~30 min) and they wake up later (~15 min). The change in sleep duration is driven by night sleep and it is homogeneously distributed across the week. The former results apply to men and women alike, and to individuals of all ages and employment status, including employed individuals, the presumed major victims of the sleep deprivation epidemic and the 24/7 society. In fact, employed individuals have experienced a reduction in short sleeping of almost 4 percentage points, from 14.9% to 11.0%. There has also been a reduction of 15 percentage points in the amount of conflict between workers work time and their sleep time, as measured by the proportion of workers that do some work within their "ideal sleep window" (as defined by their own chronotype).


Assuntos
Distúrbios do Início e da Manutenção do Sono/epidemiologia , Sono/fisiologia , Feminino , História do Século XX , História do Século XXI , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Fatores de Tempo , Reino Unido
18.
J Sleep Res ; 28(2): e12786, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30421469

RESUMO

Quantification of sleep is important for the diagnosis of sleep disorders and sleep research. However, the only widely accepted method to obtain sleep staging is by visual analysis of polysomnography (PSG), which is expensive and time consuming. Here, we investigate automated sleep scoring based on a low-cost, mobile electroencephalogram (EEG) platform consisting of a lightweight EEG amplifier combined with flex-printed cEEGrid electrodes placed around the ear, which can be implemented as a fully self-applicable sleep system. However, cEEGrid signals have different amplitude characteristics to normal scalp PSG signals, which might be challenging for visual scoring. Therefore, this study evaluates the potential of automatic scoring of cEEGrid signals using a machine learning classifier ("random forests") and compares its performance with manual scoring of standard PSG. In addition, the automatic scoring of cEEGrid signals is compared with manual annotation of the cEEGrid recording and with simultaneous actigraphy. Acceptable recordings were obtained in 15 healthy volunteers (aged 35 ± 14.3 years) during an extended nocturnal sleep opportunity, which induced disrupted sleep with a large inter-individual variation in sleep parameters. The results demonstrate that machine-learning-based scoring of around-the-ear EEG outperforms actigraphy with respect to sleep onset and total sleep time assessments. The automated scoring outperforms human scoring of cEEGrid by standard criteria. The accuracy of machine-learning-based automated scoring of cEEGrid sleep recordings compared with manual scoring of standard PSG was satisfactory. The findings show that cEEGrid recordings combined with machine-learning-based scoring holds promise for large-scale sleep studies.


Assuntos
Actigrafia/métodos , Eletroencefalografia/métodos , Aprendizado de Máquina/normas , Fases do Sono/fisiologia , Transtornos do Sono-Vigília/diagnóstico , Adulto , Feminino , Humanos , Masculino
19.
Biomed Eng Online ; 18(1): 51, 2019 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-31053071

RESUMO

BACKGROUND: Avoidance to look others in the eye is a characteristic symptom of Autism Spectrum Disorders (ASD), and it has been hypothesised that quantitative monitoring of gaze patterns could be useful to objectively evaluate treatments. However, tools to measure gaze behaviour on a regular basis at a manageable cost are missing. In this paper, we investigated whether a smartphone-based tool could address this problem. Specifically, we assessed the accuracy with which the phone-based, state-of-the-art eye-tracking algorithm iTracker can distinguish between gaze towards the eyes and the mouth of a face displayed on the smartphone screen. This might allow mobile, longitudinal monitoring of gaze aversion behaviour in ASD patients in the future. RESULTS: We simulated a smartphone application in which subjects were shown an image on the screen and their gaze was analysed using iTracker. We evaluated the accuracy of our set-up across three tasks in a cohort of 17 healthy volunteers. In the first two tasks, subjects were shown different-sized images of a face and asked to alternate their gaze focus between the eyes and the mouth. In the last task, participants were asked to trace out a circle on the screen with their eyes. We confirm that iTracker can recapitulate the true gaze patterns, and capture relative position of gaze correctly, even on a different phone system to what it was trained on. Subject-specific bias can be corrected using an error model informed from the calibration data. We compare two calibration methods and observe that a linear model performs better than a previously proposed support vector regression-based method. CONCLUSIONS: Under controlled conditions it is possible to reliably distinguish between gaze towards the eyes and the mouth with a smartphone-based set-up. However, future research will be required to improve the robustness of the system to roll angle of the phone and distance between the user and the screen to allow deployment in a home setting. We conclude that a smartphone-based gaze-monitoring tool provides promising opportunities for more quantitative monitoring of ASD.


Assuntos
Transtorno do Espectro Autista/fisiopatologia , Movimentos Oculares , Smartphone , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA