Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 40(25): 2070-2085, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29992264

RESUMO

Non-adherence has been well recognized for years to be a common issue that significantly impacts clinical outcomes and health care costs. Medication adherence is remarkably low even in the controlled environment of clinical trials where it has potentially complex major implications. Collection of non-adherence data diverge markedly among cardiovascular randomized trials and, even where collected, is rarely incorporated in the statistical analysis to test the consistency of the primary endpoint(s). The imprecision introduced by the inconsistent assessment of non-adherence in clinical trials might confound the estimate of the calculated efficacy of the study drug. Hence, clinical trials may not accurately answer the scientific question posed by regulators, who seek an accurate estimate of the true efficacy and safety of treatment, or the question posed by payers, who want a reliable estimate of the effectiveness of treatment in the marketplace after approval. The Non-adherence Academic Research Consortium is a collaboration among leading academic research organizations, representatives from the U.S. Food and Drug Administration and physician-scientists from the USA and Europe. One in-person meeting was held in Madrid, Spain, culminating in a document describing consensus recommendations for reporting, collecting, and analysing adherence endpoints across clinical trials. The adoption of these recommendations will afford robustness and consistency in the comparative safety and effectiveness evaluation of investigational drugs from early development to post-marketing approval studies. These principles may be useful for regulatory assessment, as well as for monitoring local and regional outcomes to guide quality improvement initiatives.


Assuntos
Fármacos Cardiovasculares/uso terapêutico , Doenças Cardiovasculares/tratamento farmacológico , Sistema Cardiovascular/efeitos dos fármacos , Custos de Cuidados de Saúde/estatística & dados numéricos , Adesão à Medicação/estatística & dados numéricos , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/economia , Estudos de Casos e Controles , Consenso , Tomada de Decisões , Humanos , Análise de Intenção de Tratamento/estatística & dados numéricos , Adesão à Medicação/psicologia , Médicos/organização & administração , Placebos/administração & dosagem , Medição de Risco , Segurança , Sociedades Científicas/organização & administração , Espanha/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , United States Food and Drug Administration/organização & administração
2.
Circulation ; 137(24): 2635-2650, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29891620

RESUMO

The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.


Assuntos
Bioprótese/normas , Implante de Prótese Vascular/normas , Prótese Vascular/normas , Vasos Coronários/cirurgia , Desenho de Prótese/normas , Stents/normas , Estenose da Valva Aórtica , Ensaios Clínicos como Assunto , Consenso , Humanos
3.
Lancet ; 392(10151): 940-949, 2018 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-30166073

RESUMO

BACKGROUND: We hypothesised that ticagrelor, in combination with aspirin for 1 month, followed by ticagrelor alone, improves outcomes after percutaneous coronary intervention compared with standard antiplatelet regimens. METHODS: GLOBAL LEADERS was a randomised, open-label superiority trial at 130 sites in 18 countries. Patients undergoing percutaneous coronary intervention with a biolimus A9-eluting stent for stable coronary artery disease or acute coronary syndromes were randomly assigned (1:1) to 75-100 mg aspirin daily plus 90 mg ticagrelor twice daily for 1 month, followed by 23 months of ticagrelor monotherapy, or standard dual antiplatelet therapy with 75-100 mg aspirin daily plus either 75 mg clopidogrel daily (for patients with stable coronary artery disease) or 90 mg ticagrelor twice daily (for patients with acute coronary syndromes) for 12 months, followed by aspirin monotherapy for 12 months. Randomisation was concealed, stratified by centre and clinical presentation (stable coronary artery disease vs acute coronary syndrome), and blocked, with randomly varied block sizes of two and four. The primary endpoint at 2 years was a composite of all-cause mortality or non-fatal centrally adjudicated new Q-wave myocardial infarction as assessed by a core lab in a blinded manner. The key secondary safety endpoint was site-reported bleeding assessed according to the Bleeding Academic Research Consortium criteria (grade 3 or 5). Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01813435, and is closed to new participants, with follow-up completed. FINDINGS: Between July 1, 2013, and Nov 9, 2015, 15 968 participants were randomly assigned, 7980 to the experimental group and 7988 to the control group. At 2 years, 304 (3·81%) participants in the experimental group had died or had a non-fatal centrally adjudicated new Q-wave myocardial infarction, compared with 349 (4·37%) participants in the control group (rate ratio 0·87 [95% CI 0·75-1·01]; p=0·073]). There was no evidence for a difference in treatment effects for the primary endpoint across prespecified subgroups of acute coronary syndromes and stable coronary artery disease (p=0·93). Grade 3 or 5 bleeding occurred in 163 participants in the experimental group and 169 in the control group (2·04% vs 2·12%; rate ratio 0·97 [95% CI 0·78-1·20]; p=0·77). INTERPRETATION: Ticagrelor in combination with aspirin for 1 month followed by ticagrelor alone for 23 months was not superior to 12 months of standard dual antiplatelet therapy followed by 12 months of aspirin alone in the prevention of all-cause mortality or new Q-wave myocardial infarction 2 years after percutaneous coronary intervention. FUNDING: AstraZeneca, Biosensors, and The Medicines Company.


Assuntos
Adenosina/análogos & derivados , Aspirina/administração & dosagem , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio/mortalidade , Inibidores da Agregação Plaquetária/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Adenosina/administração & dosagem , Idoso , Clopidogrel , Angiografia Coronária , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/mortalidade , Quimioterapia Combinada , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea , Ticagrelor , Ticlopidina/administração & dosagem , Ticlopidina/análogos & derivados
4.
Eur Heart J ; 39(23): 2192-2207, 2018 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-29897428

RESUMO

The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.


Assuntos
Ensaios Clínicos como Assunto , Doença da Artéria Coronariana/terapia , Equipamentos e Provisões , Medidas de Resultados Relatados pelo Paciente , Implantes Absorvíveis , Ásia , Europa (Continente) , Humanos , Avaliação de Resultados em Cuidados de Saúde , Stents , Alicerces Teciduais , Estados Unidos
5.
Eur Heart J ; 39(19): 1687-1697, 2018 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-28171522

RESUMO

Surgical and catheter-based cardiovascular procedures and adjunctive pharmacology have an inherent risk of neurological complications. The current diversity of neurological endpoint definitions and ascertainment methods in clinical trials has led to uncertainties in the neurological risk attributable to cardiovascular procedures and inconsistent evaluation of therapies intended to prevent or mitigate neurological injury. Benefit-risk assessment of such procedures should be on the basis of an evaluation of well-defined neurological outcomes that are ascertained with consistent methods and capture the full spectrum of neurovascular injury and its clinical effect. The Neurologic Academic Research Consortium is an international collaboration intended to establish consensus on the definition, classification, and assessment of neurological endpoints applicable to clinical trials of a broad range of cardiovascular interventions. Systematic application of the proposed definitions and assessments will improve our ability to evaluate the risks of cardiovascular procedures and the safety and effectiveness of preventive therapies.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Ensaios Clínicos como Assunto , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/etiologia , Cateterismo/efeitos adversos , Determinação de Ponto Final , Humanos , Doenças do Sistema Nervoso/classificação , Exame Neurológico , Complicações Pós-Operatórias , Medição de Risco
6.
Eur Heart J ; 38(42): 3124-3134, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-29020367

RESUMO

Aims: To investigate if recent technical and procedural developments in percutaneous coronary intervention (PCI) significantly influence outcomes in appropriately selected patients with three-vessel (3VD) coronary artery disease. Methods and results: The SYNTAX II study is a multicenter, all-comers, open-label, single arm study that investigated the impact of a contemporary PCI strategy on clinical outcomes in patients with 3VD in 22 centres from four European countries. The SYNTAX-II strategy includes: heart team decision-making utilizing the SYNTAX Score II (a clinical tool combining anatomical and clinical factors), coronary physiology guided revascularisation, implantation of thin strut bioresorbable-polymer drug-eluting stents, intravascular ultrasound (IVUS) guided stent implantation, contemporary chronic total occlusion revascularisation techniques and guideline-directed medical therapy. The rate of major adverse cardiac and cerebrovascular events (MACCE [composite of all-cause death, cerebrovascular event, any myocardial infarction and any revascularisation]) at one year was compared to a predefined PCI cohort from the original SYNTAX-I trial selected on the basis of equipoise 4-year mortality between CABG and PCI. As an exploratory endpoint, comparisons were made with the historical CABG cohort of the original SYNTAX-I trial. Overall 708 patients were screened and discussed within the heart team; 454 patients were deemed appropriate to undergo PCI. At one year, the SYNTAX-II strategy was superior to the equipoise-derived SYNTAX-I PCI cohort (MACCE SYNTAX-II 10.6% vs. SYNTAX-I 17.4%; HR 0.58, 95% CI 0.39-0.85, P = 0.006). This difference was driven by a significant reduction in the incidence of MI (HR 0.27, 95% CI 0.11-0.70, P = 0.007) and revascularisation (HR 0.57, 95% CI 0.37-0.9, P = 0.015). Rates of all-cause death (HR 0.69, 95% CI 0.27-1.73, P = 0.43) and stroke (HR 0.69, 95% CI 0.10-4.89, P = 0.71) were similar. The rate of definite stent thrombosis was significantly lower in SYNTAX-II (HR 0.26, 95% CI 0.07-0.97, P = 0.045). Conclusion: At one year, clinical outcomes with the SYNTAX-II strategy were associated with improved clinical results compared to the PCI performed in comparable patients from the original SYNTAX-I trial. Longer term follow-up is awaited and a randomized clinical trial with contemporary CABG is warranted. ClinicalTrials.gov Identifier: NCT02015832.


Assuntos
Doença da Artéria Coronariana/cirurgia , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Implantes Absorvíveis , Idoso , Angioplastia Coronária com Balão/métodos , Atorvastatina/uso terapêutico , Ponte de Artéria Coronária/métodos , Quimioterapia Combinada , Stents Farmacológicos , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Infarto do Miocárdio/cirurgia , Inibidores da Agregação Plaquetária/uso terapêutico , Rosuvastatina Cálcica/uso terapêutico , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
7.
Lancet ; 387(10016): 357-366, 2016 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-26520230

RESUMO

BACKGROUND: Data for the safety and efficacy of new-generation drug-eluting stents at long-term follow-up, and specifically in patients with ST-segment elevation myocardial infarction, are scarce. In the EXAMINATION trial, we compared everolimus-eluting stents (EES) with bare-metal stents (BMS) in an all-comer population with ST-segment elevation myocardial infarction. In this study, we assessed the 5-year outcomes of the population in the EXAMINATION trial. METHODS: In the multicentre EXAMINATION trial, done in Italy, Spain, and the Netherlands, patients with ST-segment elevation myocardial infarction were randomly assigned in a 1:1 ratio to receive EES or BMS. The random allocation schedule was computer-generated and central randomisation (by telephone) was used to allocate patients in blocks of four or six, stratified by centre. Patients were masked to treatment assignment. At 5 years, we assessed the combined patient-oriented outcome of all-cause death, any myocardial infarction, or any revascularisation. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00828087. FINDINGS: 1498 patients were randomly assigned to receive either EES (n=751) or BMS (n=747). At 5 years, complete clinical follow-up data were obtained for 731 patients treated with EES and 727 treated with BMS (97% of both groups). The patient-oriented endpoint occurred in 159 (21%) patients in the EES group versus 192 (26%) in the BMS group (hazard ratio 0·80, 95% CI 0·65-0·98; p=0·033). This difference was mainly driven by a reduced rate of all-cause mortality (65 [9%] vs 88 [12%]; 0·72, 0·52-0·10; p=0·047). INTERPRETATION: Our findings should be taken as a point of reference for the assessment of new bioresorbable polymer-based metallic stents or bioresorbable scaffolds in patients with ST-segment elevation myocardial infarction. FUNDING: Spanish Heart Foundation.


Assuntos
Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Infarto do Miocárdio/terapia , Avaliação de Resultados da Assistência ao Paciente , Stents , Idoso , Causas de Morte , Determinação de Ponto Final , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Estudos Prospectivos , Método Simples-Cego , Trombose/epidemiologia
8.
Am Heart J ; 184: 81-87, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27892890

RESUMO

BACKGROUND: Optimal antithrombotic treatment after transcatheter aortic valve replacement (TAVR) is unknown and determined empirically. The direct factor Xa inhibitor rivaroxaban may potentially reduce TAVR-related thrombotic complications and premature valve failure. DESIGN: GALILEO is an international, randomized, open-label, event-driven, phase III trial in more than 1,520 patients without an indication for oral anticoagulation who underwent a successful TAVR (ClinicalTrials.govNCT02556203). Patients are randomized (1:1 ratio), 1 to 7days after a successful TAVR, to either a rivaroxaban-based strategy or an antiplatelet-based strategy. In the experimental arm, subjects receive rivaroxaban (10mg once daily [OD]) plus acetylsalicylic acid (ASA, 75-100mg OD) for 90days followed by rivaroxaban alone. In the control arm, subjects receive clopidogrel (75mg OD) plus ASA (as above) for 90days followed by ASA alone. In case new-onset atrial fibrillation occurs after randomization, full oral anticoagulation will be implemented with maintenance of the original treatment assignment. The primary efficacy end point is the composite of all-cause death, stroke, myocardial infarction, symptomatic valve thrombosis, pulmonary embolism, deep venous thrombosis, and systemic embolism. The primary safety end point is the composite of life-threatening, disabling, and major bleeding, according to the Valve Academic Research Consortium definitions. CONCLUSIONS: GALILEO will test the hypothesis that a rivaroxaban-based antithrombotic strategy reduces the risk of thromboembolic complications post-TAVR with an acceptable risk of bleeding compared with the currently recommended antiplatelet therapy-based strategy in subjects without need of chronic oral anticoagulation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Aspirina/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/uso terapêutico , Substituição da Valva Aórtica Transcateter , Doenças Cardiovasculares/epidemiologia , Causas de Morte , Clopidogrel , Quimioterapia Combinada , Embolia/epidemiologia , Embolia/prevenção & controle , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/prevenção & controle , Humanos , Mortalidade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Cuidados Pós-Operatórios/métodos , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/epidemiologia , Trombose/prevenção & controle , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Trombose Venosa/epidemiologia , Trombose Venosa/prevenção & controle
9.
Am Heart J ; 182: 80-88, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27914503

RESUMO

BACKGROUND: Coexistence of moderate aortic stenosis (AS) in patients with heart failure (HF) with reduced ejection fraction is not uncommon. Moderate AS increases afterload, whereas pharmacologic reduction of afterload is a pillar of contemporary HF management. HYPOTHESIS: Unloading the left ventricle by reducing the transaortic gradient with transfemoral transcatheter aortic valve replacement (TAVR) may improve clinical outcomes in patients with moderate AS and HF with reduced ejection fraction. STUDY DESIGN: The TAVR UNLOAD (NCT02661451) is an international, multicenter, randomized, open-label, clinical trial comparing the efficacy and safety of TAVR with the Edwards SAPIEN 3 Transcatheter Heart Valve in addition to optimal heart failure therapy (OHFT) vs OHFT alone in patients with moderate AS (defined by a mean transaortic gradient ≥20 mm Hg and <40 mm Hg, and an aortic valve area >1.0 cm2 and ≤1.5 cm2 at rest or after dobutamine stress echocardiography) and reduced ejection fraction. A total of 600 patients will be randomized in a 1:1 fashion. Clinical follow-up is scheduled at 1, 6, and 12 months, and 2 years after randomization. The primary end point is the hierarchical occurrence of all-cause death, disabling stroke, hospitalizations related to HF, symptomatic aortic valve disease or nondisabling stroke, and the change in the Kansas City Cardiomyopathy Questionnaire at 1 year. Secondary end points capture effects on clinical outcome, biomarkers, echocardiographic parameters, and quality of life. SUMMARY: The TAVR UNLOAD trial aims to test the hypothesis that TAVR on top of OHFT improves clinical outcomes in patients with moderate AS and HF with reduced ejection fraction.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia sob Estresse/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
10.
Catheter Cardiovasc Interv ; 86(2): 229-35, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25620044

RESUMO

OBJECTIVES: To compare the variability in the assessment of coronary stents among interventional cardiologists (readers) using optical coherence tomography (OCT) and intravascular ultrasound (IVUS). BACKGROUND: IVUS is established and validated in the evaluation of coronary stent. For cardiologists without core lab expertise, the utility of IVUS is limited by image quality. OCT yields higher image resolution; however, the consistency with which these readers interpret OCT images has not been fully evaluated or compared with IVUS. METHODS: OCT and IVUS image sets (five pairs) obtained after stent placement were reviewed by readers with clinical experience in both modalities. Parameters assessed included stent expansion and symmetry, reference vessel and in-stent cross-sectional area (CSA) and diameter, and stent strut apposition as well as Multicenter Ultrasound Stenting in Coronaries criteria. These interpretations were compared with core lab readings and examined for interobserver variability. RESULTS: The interobserver variability for measurement of in-stent CSA was 1.34 mm(2) using IVUS compared with 0.85 mm(2) using OCT (P = 0.024). Variation in the deviation from core lab measurement of in-stent CSA for IVUS was 1.48 mm(2) compared with 0.87 mm(2) for OCT (P = 0.042). The interobserver agreement for obtaining the Multicenter Ultrasound Stenting in Coronaries criteria using IVUS was 80.4% compared with 81.1% using OCT (P = 0.78). Compared with the corelab measurement, the readers obtained an agreement of 72.7% using IVUS vs. 67.3% using OCT (P = 0.43). CONCLUSION: In the assessment of deployed coronary stents by practicing cardiologists, OCT images are interpreted more consistently compared with IVUS and can be used to assess stent deployment using IVUS-validated metrics.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Intervenção Coronária Percutânea/instrumentação , Stents , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Competência Clínica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do Tratamento
11.
Lancet ; 381(9867): 639-50, 2013 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-23439103

RESUMO

BACKGROUND: The anatomical SYNTAX score is advocated in European and US guidelines as an instrument to help clinicians decide the optimum revascularisation method in patients with complex coronary artery disease. The absence of an individualised approach and of clinical variables to guide decision making between coronary artery bypass graft surgery (CABG) and percutaneous coronary intervention (PCI) are limitations of the SYNTAX score. SYNTAX score II aimed to overcome these limitations. METHODS: SYNTAX score II was developed by applying a Cox proportional hazards model to results of the randomised all comers SYNTAX trial (n=1800). Baseline features with strong associations to 4-year mortality in either the CABG or the PCI settings (interactions), or in both (predictive accuracy), were added to the anatomical SYNTAX score. Comparisons of 4-year mortality predictions between CABG and PCI were made for each patient. Discriminatory performance was quantified by concordance statistics and internally validated with bootstrap resampling. External validation was done in the multinational all comers DELTA registry (n=2891), a heterogeneous population that included patients with three-vessel disease (26%) or complex coronary artery disease (anatomical SYNTAX score ≥33, 30%) who underwent CABG or PCI. The SYNTAX trial is registered with ClinicalTrials.gov, number NCT00114972. FINDINGS: SYNTAX score II contained eight predictors: anatomical SYNTAX score, age, creatinine clearance, left ventricular ejection fraction (LVEF), presence of unprotected left main coronary artery (ULMCA) disease, peripheral vascular disease, female sex, and chronic obstructive pulmonary disease (COPD). SYNTAX score II significantly predicted a difference in 4-year mortality between patients undergoing CABG and those undergoing PCI (p(interaction) 0·0037). To achieve similar 4-year mortality after CABG or PCI, younger patients, women, and patients with reduced LVEF required lower anatomical SYNTAX scores, whereas older patients, patients with ULMCA disease, and those with COPD, required higher anatomical SYNTAX scores. Presence of diabetes was not important for decision making between CABG and PCI (p(interaction) 0·67). SYNTAX score II discriminated well in all patients who underwent CABG or PCI, with concordance indices for internal (SYNTAX trial) validation of 0·725 and for external (DELTA registry) validation of 0·716, which were substantially higher than for the anatomical SYNTAX score alone (concordance indices of 0·567 and 0·612, respectively). A nomogram was constructed that allowed for an accurate individualised prediction of 4-year mortality in patients proposing to undergo CABG or PCI. INTERPRETATION: Long-term (4-year) mortality in patients with complex coronary artery disease can be well predicted by a combination of anatomical and clinical factors in SYNTAX score II. SYNTAX score II can better guide decision making between CABG and PCI than the original anatomical SYNTAX score. FUNDING: Boston Scientific Corporation.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Tomada de Decisões , Medição de Risco , Fatores Etários , Creatinina/análise , Feminino , Humanos , Masculino , Seleção de Pacientes , Doenças Vasculares Periféricas/epidemiologia , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Sistólico
12.
Circ J ; 78(8): 1873-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24942012

RESUMO

BACKGROUND: Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS: In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS: Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Monitorização Fisiológica/métodos , Tomografia de Coerência Óptica , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino
13.
Eur Heart J ; 34(14): 1050-60, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23396493

RESUMO

AIMS: Primary percutaneous coronary intervention (PPCI) with thrombectomy (TB) seems to reduce the thrombus burden, resulting in a larger flow area as measured with optical frequency domain imaging (OFDI). METHODS AND RESULTS: In a multi-centre study, 141 patients with ST elevation myocardial infarction <12 h from onset were randomized to either PPCI with TB using an Eliminate catheter (TB: n = 71) or without TB (non-TB: n = 70), having operators blinded for the OFDI results. The primary endpoint was minimum flow area (MinFA) post-procedure assessed by OFDI, defined as: [stent area + incomplete stent apposition (ISA) area] - (intraluminal defect + tissue prolapse area). Sample size was based on the expected difference of 0.72 mm(2) in MinFA. Baseline demographics, pre-procedural quantitative coronary angiography (QCA), and procedural characteristics were well matched between the two groups. On OFDI, the stent area (TB: 7.62 ± 2.23 mm(2), non-TB: 7.05 ± 2.12 mm(2), P = 0.14) and MinFA (TB: 7.08 ± 2.14 mm(2) vs. non-TB: 6.51 ± 1.99 mm(2), Δ0.57 mm(2), P = 0.12) were not different. In addition, the amount of protrusion, intraluminal defect, and ISA area were similar in the both groups. CONCLUSION: PPCI with TB was associated with a similar flow area as well as stent area to PPCI without TB.


Assuntos
Trombose Coronária/terapia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Trombectomia/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Imagem Cardíaca/métodos , Circulação Coronária/fisiologia , Trombose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento
14.
Lancet ; 380(9852): 1482-90, 2012 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-22951305

RESUMO

BACKGROUND: Everolimus-eluting stent (EES) reduces the risk of restenosis in elective percutaneous coronary intervention. However, the use of drug-eluting stent in patients with ST-segment elevation myocardial infarction (STEMI) is still controversial. Data regarding the performance of second-generation EES in this setting are scarce. We report the 1-year result of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) trial, comparing EES with bare-metal stents (BMS) in patients with STEMI. METHODS: This multicentre, prospective, randomised, all-comer controlled trial was done in 12 medical centres in three countries. Between Dec 31, 2008, and May 15, 2010, we recruited patients with STEMI up to 48 h after the onset of symptoms requiring emergent percutaneous coronary intervention. Patients were randomly assigned (ratio 1:1) to receive EES or BMS. Randomisation was in blocks of four or six patients, stratified by centre and centralised by telephone. Patients were masked to treatment. The primary endpoint was the patient-oriented combined endpoint of all-cause death, any recurrent myocardial infarction, and any revascularisation at 1 year and was analysed by intention to treat. The secondary endpoints of the study included the device-oriented combined endpoint of cardiac death, target vessel myocardial infarction or target lesion revascularisation, and rates of all cause or cardiac death, recurrent myocardial infarction, target lesion or target vessel revascularisation, stent thrombosis, device and procedure success, and major and minor bleeding. This trial is registered with ClinicalTrials.gov, number NCT00828087. FINDINGS: Of the 1504 patients randomised, 1498 patients were randomly assigned to receive EES (n=751) or BMS (n=747). The primary endpoint was similar in both groups (89 [11·9%] of 751 patients in the EES group vs 106 [14·2%] of 747 patients in the BMS group; difference -2·34 [95% CI -5·75 to 1·07]; p=0·19). Device-oriented endpoint (44 [5·9%] in the EES group vs 63 [8·4%] in the BMS group; difference -2·57 [95% CI -5·18 to 0·03]; p=0·05) did not differ between groups, although rates of target lesion and vessel revascularisation were significantly lower in the EES group (16 [2·1%] vs 37 [5·0%], p=0·003, and 28 [3·7%] vs 51 [6·8%], p=0·0077, respectively). Rates of all cause (26 [3·5%] for EES vs 26 [3·5%] for BMS, p=1·00) or cardiac death (24 [3·2%] for EES vs 21 [2·8%] for BMS, p=0·76) or myocardial infarction (10 [1·3%] vs 15 [2·0%], p=0·32) did not differ between groups. Stent thrombosis rates were significantly lower in the EES group (4 [0·5%] patients with definite stent thrombosis in the EES group vs 14 [1·9%] in the BMS group and seven [0·9%] patients with definite or probable stent thrombosis in the EES group vs 19 [2·5%] in the BMS group, both p=0·019). Although device success rate was similar between groups, procedure success rate was significantly higher in the EES group (731 [97·5%] vs 705 [94·6%]; p=0·0050). Finally, Bleeding rates at 1 year were comparable between groups (29 [3·9%] patients in the EES group vs 39 [5·2%] in the BMS group; p=0·19). INTERPRETATION: The use of EES compared with BMS in the setting of STEMI did not lower the patient-oriented endpoint. However, at the stent level both rates of target lesion revascularisation and stent thrombosis were reduced in recipients of EES. FUNDING: Spanish Heart Foundation.


Assuntos
Ligas de Cromo , Stents Farmacológicos , Imunossupressores/administração & dosagem , Infarto do Miocárdio/terapia , Sirolimo/análogos & derivados , Stents , Eletrocardiografia , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Método Simples-Cego , Sirolimo/administração & dosagem
15.
Am Heart J ; 166(1): 83-94, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23816026

RESUMO

BACKGROUND: Histologic experimental studies have reported incomplete neointimal healing in overlapping with respect to nonoverlapping segments in drug-eluting stents (DESs), but these observations have not been confirmed in human coronary arteries hitherto. On the contrary, angiographic and optical coherence tomography studies suggest that DES overlap elicits rather an exaggerated than an incomplete neointimal reaction. METHODS: Optical coherence tomography studies from 2 randomized trials including sirolimus-eluting, biolimus-eluting, everolimus-eluting, and zotarolimus-eluting stents were analyzed at 9- to 13-month follow-up. Coverage in overlapping segments was compared versus the corresponding nonoverlapping segments of the same stents, using statistical pooled analysis. RESULTS: Forty-two overlaps were found in 31 patients: 11 in sirolimus-eluting stents, 3 in biolimus-eluting stents, 17 in everolimus-eluting stents, and 11 in zotarolimus-eluting stents. The risk ratio of incomplete coverage was 2.35 (95% CI 1.86-2.98) in overlapping versus nonoverlapping segments. Thickness of coverage in overlaps was only 85% (95% CI 81%-90%) of the thickness in nonoverlaps. Significant heterogeneity of the effect was observed, especially pronounced in the comparison of thickness of coverage (I(2) = 90.31). CONCLUSIONS: The effect of overlapping DES on neointimal inhibition is markedly heterogeneous: on average, DES overlap is associated with more incomplete and thinner coverage, but in some cases, the overlap elicits an exaggerated neointimal reaction, thicker than in the corresponding nonoverlapping segments. These results might help to understand why overlapping DES is associated with worse clinical outcomes, both in terms of thrombotic phenomena and in terms of restenosis and revascularization.


Assuntos
Estenose Coronária/cirurgia , Vasos Coronários/patologia , Stents Farmacológicos , Tomografia de Coerência Óptica/métodos , Reestenose Coronária/diagnóstico , Reestenose Coronária/prevenção & controle , Estenose Coronária/patologia , Everolimo , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Hiperplasia , Imunossupressores , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Desenho de Prótese , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Fatores de Tempo , Resultado do Tratamento
16.
Eur Heart J ; 33(19): 2403-18, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23026477

RESUMO

OBJECTIVES: The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI)clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection. BACKGROUND: A recent study confirmed that VARC definitions have already been incorporated into clinical and research practice and represent a new standard for consistency in reporting clinical outcomes of patients with symptomatic severe aortic stenosis (AS) undergoing TAVI. However, as the clinical experience with this technology has matured and expanded, certain definitions have become unsuitable or ambiguous. METHODS AND RESULTS: Two in-person meetings (held in September 2011 in Washington, DC, USA, and in February 2012 in Rotterdam, the Netherlands) involving VARC study group members, independent experts (including surgeons, interventional and non-interventional cardiologists, imaging specialists, neurologists, geriatric specialists, and clinical trialists), the US Food and Drug Administration (FDA), and industry representatives, provided much of the substantive discussion from which this VARC-2 consensus manuscript was derived. This document provides an overview of risk assessment and patient stratification that need to be considered for accurate patient inclusion in studies. Working groups were assigned to define the following clinical endpoints: mortality, stroke, myocardial infarction, bleeding complications, acute kidney injury, vascular complications, conduction disturbances and arrhythmias, and a miscellaneous category including relevant complications not previously categorized. Furthermore, comprehensive echocardiographic recommendations are provided for the evaluation of prosthetic valve (dys)function. Definitions for the quality of life assessments are also reported. These endpoints formed the basis for several recommended composite endpoints. CONCLUSIONS: This VARC-2 document has provided further standardization of endpoint definitions for studies evaluating the use of TAVI, which will lead to improved comparability and interpretability of the study results, supplying an increasingly growing body of evidence with respect to TAVI and/or surgical aortic valve replacement. This initiative and document can furthermore be used as a model during current endeavours of applying definitions to other transcatheter valve therapies (for example, mitral valve repair).


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/normas , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Injúria Renal Aguda/etiologia , Estenose da Valva Aórtica/mortalidade , Arritmias Cardíacas/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , District of Columbia , Determinação de Ponto Final , Traumatismos Cardíacos/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemorragia/etiologia , Humanos , Infarto do Miocárdio/etiologia , Países Baixos , Seleção de Pacientes , Falha de Prótese , Qualidade de Vida , Padrões de Referência , Medição de Risco , Acidente Vascular Cerebral/etiologia , Calcificação Vascular/mortalidade , Calcificação Vascular/cirurgia , Doenças Vasculares/etiologia
17.
Eur Heart J ; 33(24): 3105-13, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23103663

RESUMO

AIMS: The aim of this investigation was to determine the incidence and multivariable correlates of long-term (4-year) mortality in patients treated with surgical or percutaneous revascularization in the synergy between percutaneous coronary intervention (PCI) with TAXUS Express and Cardiac Surgery (SYNTAX) trial. METHODS AND RESULTS: A total of 1800 patients were randomized to undergo coronary artery bypass graft (CABG) surgery (n = 897) or PCI (n = 903). Prospectively collected baseline and peri- and post-procedural data were used to determine independent correlates of 4-year all-cause death in the CABG and the PCI arms (Cox proportional hazards model). Four-year mortality rates in the CABG and the PCI arms were 9.0% [74 deaths (12 in-hospital)] and 11.8% [104 deaths (16 in-hospital)], respectively (log-rank P-value = 0.063). Censored data comprised 78 patients (8.7%) in the CABG arm, and 24 patients (2.7%) in the PCI arm (log-rank P-value < 0.001). Within the CABG arm, the strongest independent correlates of 4-year mortality were lack of discharge aspirin [hazard ratio (HR) 3.56; 95% CI: 2.04, 6.21; P < 0.001], peripheral vascular disease (PVD) (HR: 2.65; 95% CI: 1.49, 4.72; P = 0.001), chronic obstructive pulmonary disease, age, and serum creatinine. Within the PCI arm, the strongest independent correlate of 4-year mortality was lack of post-procedural anti-platelet therapy (HR: 152.16; 95% CI: 53.57, 432.22; P < 0.001), with 10 reported early (within 45 days) in-hospital deaths secondary to multifactorial causes precluding administration of anti-platelet therapy. Other independent correlates of mortality in the PCI arm included amiodarone therapy on discharge, pre-procedural poor left ventricular ejection fraction, a 'history of gastrointestinal bleeding or peptic ulcer disease', PVD (HR: 2.13; 95% CI: 1.26, 3.60; P = 0.005), age, female gender (HR: 1.60; 95% CI: 1.01, 2.56; P = 0.048), and the SYNTAX score (Per increase in 10 points: HR: 1.25; 95% CI: 1.06, 1.47; P = 0.007). CONCLUSION: Independent correlates of 4-year mortality in the SYNTAX trial were multifactorial. Lack of discharge aspirin and lack of post-procedural anti-platelet therapy were the strongest independent correlates of mortality in the CABG and the PCI arms, respectively. Peripheral vascular disease is a common independent correlate of 4-year mortality and may be a marker of the severity of baseline coronary disease and risk of future native coronary disease (and extra-cardiac disease) progression.


Assuntos
Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/mortalidade , Idoso , Amiodarona/uso terapêutico , Doença da Artéria Coronariana/mortalidade , Feminino , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/mortalidade , Humanos , Masculino , Doenças Vasculares Periféricas/complicações , Doenças Vasculares Periféricas/mortalidade , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Fatores Sexuais , Vasodilatadores/uso terapêutico
18.
Circulation ; 124(5): 612-23, 2011 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-21768536

RESUMO

BACKGROUND: Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. METHODS AND RESULTS: Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I(2)=38.40) but not in the other comparisons. CONCLUSIONS: Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography. Clinical Trial Registration- http://www.clinicaltrials.gov. Unique identifier: NCT00389220, NCT00617084.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Reestenose Coronária/diagnóstico , Reestenose Coronária/epidemiologia , Stents Farmacológicos/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Tomografia de Coerência Óptica , Idoso , Angioplastia Coronária com Balão/métodos , Vasos Coronários , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Fatores de Risco
19.
Lancet ; 378(9807): 1940-8, 2011 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-22075451

RESUMO

BACKGROUND: The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. METHODS: We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049). INTERPRETATION: Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. FUNDING: Biosensors Europe SA, Switzerland.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Polímeros , Sirolimo/análogos & derivados , Seguimentos , Humanos , Trombose/etiologia
20.
Catheter Cardiovasc Interv ; 79(6): 890-902, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21523891

RESUMO

OBJECTIVE: To report the agreement between gray-scale intravascular ultrasound (GS-IVUS) and optical coherence tomography (OCT) in assessing the bioresorbable vascular scaffolds (BVS) structures and their respective reproducibility. BACKGROUND: BVS are composed of an erodible polymer. Ultrasound and light signals backscattered from polymeric material differs from metallic stents using GS-IVUS and OCT. METHODS: Forty-five patients included in the ABSORB trial were treated with a 3.0 × 18 mm BVS and imaged with GS-IVUS 20 MHz and OCT post-implantation. Qualitative (ISA, side-branch struts, protrusion, and dissections) and quantitative (number of struts, lumen, and scaffold area) measurements were assessed by two investigators. The agreement and the inter- and intraobserver reproducibility were investigated using the kappa (κ) and the interclass correlation coefficient (ICC). RESULTS: GS-IVUS and OCT agreement was predominantly poor at a lesion, frame, and strut level analysis (κ and ICC <0.4) for qualitative measurements. GS-IVUS demonstrated a reduced ability to detect cross-sections with ISA (4.5% vs. 20.6%), side-branch (SB) struts (6.3% vs. 7.8%), protrusions (3.2% vs. 9.6%), and dissections (0.2% vs. 9.0%) compared with OCT. GS-IVUS reproducibility was poor-moderate (κ and ICC <0.6) except for ISA and SB-struts (κ and ICC between 0.2 and 0.75). OCT showed an excellent reproducibility (κ and ICC > 0.75) except for the assessment of tissue protrusion (κ and ICC between 0.47 and 0.94). GS-IVUS reproducibility was poor-moderate (ICC ≤ 0.5) in assessing the number of struts but excellent with OCT (ICC > 0.85). The reproducibility to assess lumen and scaffold areas was excellent using both techniques (ICC > 0.85). CONCLUSIONS: GS-IVUS has a poor capacity to detect qualitative findings post-BVS implantation and its reproducibility is low compared with OCT. The use of GS-IVUS should be limited when assessing lumen and scaffold areas.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Isquemia Miocárdica/terapia , Sirolimo/análogos & derivados , Alicerces Teciduais , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Portadores de Fármacos , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA