RESUMO
OBJECTIVE: The elevated risk of adverse events following percutaneous coronary intervention in diabetic patients persists with newer-generation DES. The polymer-free amphilimus-eluting stent (PF-AES) possesses characteristics with a potentially enhanced performance in patients with diabetes. Data from the 1-year follow-up period has been previously published. The aim of this subanalysis was to assess long-term performance of two contemporary drug-eluting stents (DES) in a diabetic population. METHODS: In the ReCre8 trial, patients were stratified for diabetes and troponin status, and randomized to implantation of a permanent polymer zotarolimus-eluting stent (PP-ZES) or PF-AES. The primary endpoint was target-lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. Clinical outcomes between discharge and 3 years follow-up were assessed. RESULTS: A total of 302 patients with diabetes were included in this analysis. After 3 years, TLF occurred in 12.5% of PP-ZES patients versus 10.0% in PF-AES patients (p = 0.46). Similarly, the separate components of TLF were comparable between the two study arms. The secondary composite endpoint of NACE was higher in the PP-ZES arm with 45 cases (29.6%) versus 30 cases (20.0%) in the PF-AES arm (p = 0.036). In the insulin-dependent diabetic population, TLF occurred in 19.1% of PP-ZES patients versus 10.4% of PF-AES patients (p = 0.21). NACE occurred in 40.4% of PP-ZES patients versus 27.1% of PF-AES patients (p = 0.10). CONCLUSIONS: This subanalysis shows that the use of PF-AES results in similar clinical outcomes as compared to PP-ZES, yet some benefits of use of PF-AES in diabetic patients may prevail. Future dedicated trials should confirm these findings.
Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/induzido quimicamente , Seguimentos , Fatores de Risco , Resultado do Tratamento , Diabetes Mellitus/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversosRESUMO
OBJECTIVE: The importance of revascularisation of significant coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. Despite the lack of randomised controlled trials comparing different revascularisation strategies, guidelines currently recommend percutaneous coronary intervention (PCI) in patients with significant proximal CAD undergoing TAVI. METHODS: In this systematic review and meta-analysis, a systematic search was conducted to identify studies comparing TAVI with and without PCI in patients with significant CAD on pre-TAVI coronary angiography. Endpoints were all-cause mortality, cardiac death, stroke, myocardial infarction and major bleeding. RESULTS: In total, 14 studies were included, involving 3838 patients, of whom 1806 (47%) underwent PCI before TAVI. All-cause mortality did not differ significantly between TAVI with and without preceding PCI at 30 days, 1 year and >â¯1 year. There were no significant differences in risk of cardiac death, stroke or myocardial infarction between the groups. However, TAVI performed with PCI resulted in a higher risk of major bleeding within 30 days after TAVI (odds ratio: 0.66; 95% confidence interval: 0.46-0.94). CONCLUSION: This systematic review and meta-analysis showed no significant differences in clinical outcomes between patients with concomitant significant CAD who were treated with TAVI with and without preceding PCI at both short- and long-term follow-up. However, there was a higher risk of major bleeding at 30 days in patients undergoing TAVI with preceding PCI. In the context of serious risk of bias in the included studies, results of randomised controlled trials are warranted.
RESUMO
OBJECTIVES: The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics. BACKGROUND: The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics. METHODS: In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. RESULTS: In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022). CONCLUSIONS: Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.
Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/induzido quimicamente , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Stents , Resultado do TratamentoRESUMO
Objectives: In an all-comers cohort undergoing percutaneous coronary intervention (PCI), we aimed to assess prevalence of high bleeding risk (HBR) patients and impact of HBR and dual antiplatelet therapy (DAPT) on clinical events. Background: HBR represents a complex subgroup of patients undergoing PCI. Methods: In the ReCre8 trial, patients undergoing PCI were stratified for troponin status and diabetes and randomized to a permanent polymer zotarolimus-eluting- or polymer-free amphilimus-eluting stent. Patients were treated with 12 months (troponin-positive) or one month (troponin-negative) of DAPT. We evaluated clinical outcomes in patients with and without HBR according to the Academic Research Consortium for High Bleeding Risk criteria. Results: From a total of 1488 patients included in this subanalysis, 406 patients (27.3 %) were identified as being at HBR. Among HBR patients, target-lesion failure (TLF) was similar after one year yet was higher after three years (13.3 % vs. 9.1 %; p = 0.013), compared to non-HBR patients. There was no difference in Bleeding Academic Research Consortium (BARC) 3 to 5 bleeding, however BARC 2 to 5 bleeding was higher after three years with 4.9 % vs. 3.0 % (p = 0.037). There were no differences between troponin-positive (12-months DAPT) and -negative (1-month DAPT) HBR patients with respect to ischemic and bleeding outcomes. Conclusions: In this all-comers population of PCI patients, a higher TLF rate among HBR patients at long-term follow-up was found, underlining the complexities involving treatment of HBR patients. We did not observe statistically significant differences in BARC 3 to 5 bleeding between HBR and non-HBR patients regardless of DAPT duration. Clinical trial registration: URL: http://www.clinicaltrials.gov, unique identifier: NCT02328898.
RESUMO
OBJECTIVES: The aim of this analysis was to assess long-term clinical outcomes of the polymer-free Amphilimus-eluting stent (PF-AES) compared with a latest generation permanent-polymer drug-eluting stent (DES) in an all-comers population. BACKGROUND: PF-AES possess multiple properties improving targeted drug elution without the presence of polymers. Evaluation of long-term clinical performance of PF-AES versus latest generation permanent-polymer DES has not yet been performed in a large randomized trial introducing shortened dual-antiplatelet therapy. METHODS: In this physician-initiated, multicenter, randomized, all-comers trial, patients undergoing percutaneous coronary intervention with implantation of DES were enrolled. Patients were stratified for diabetes and troponin status and randomized to implantation of a permanent-polymer zotarolimus-eluting stent (PP-ZES) or a PF-AES. Dual-antiplatelet therapy duration was 12 months in troponin-positive patients and 1 month in troponin-negative patients. A noninferiority analysis was conducted to compare the 2 arms regarding target lesion failure (TLF) between 1 and 3 years. RESULTS: A total of 1,491 patients were randomized and treated. In this landmark analysis, between 1- and 3-year follow-up, TLF occurred in 35 patients (4.9%) in the PP-ZES arm and 37 PF-AES patients (5.1%). Clinical noninferiority of the PF-AES was confirmed, with a risk difference of 0.2% (upper limit 1-sided 95% CI: 2.2%; Pnoninferiority = 0.0031). CONCLUSIONS: ReCre8 (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent) is the first randomized, multicenter trial with a head-to-head comparison of PP-ZES compared with PF-AES to investigate clinical outcomes of these new-generation DES in an all-comers population with long-term follow-up. On the basis of the present results, PF-AES are clinically noninferior to PP-ZES regarding TLF between 1 and 3 years. (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent; NCT02328898).