Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Dig Endosc ; 34(3): 596-603, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34245614

RESUMO

BACKGROUND: The effects of the Franseen needle size in endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of solid pancreatic masses remain unclear. This study aimed to compare 25G and 22G Franseen needles in terms of adequate tissue acquisition from solid pancreatic masses. METHODS: In this single-center, crossover, randomized noninferiority trial, eligible patients underwent EUS-FNB with both 25G and 22G Franseen needles in a randomized order between November 2018 and August 2020. Tissue specimens from each pass were separately evaluated based on the cellularity scoring system. The primary outcome was the proportion of acquired specimens allowing adequate histological assessment (cellularity score ≥3). A -15% noninferiority margin was assumed. RESULTS: Data from 88 patients were analyzed, which showed malignant and benign lesions in 84 (95.5%) and four (4.5%) patients, respectively. Of the 88 specimens, 62 (70.5%) and 69 (78.4%) acquired using 25G and 22G needles, respectively, allowed adequate histological assessment. The adjusted proportion difference was -6.6% (95% confidence interval -8.8% to -4.5%), indicating noninferiority of the 25G Franseen needle (P < 0.001). The diagnostic accuracies of the 25G and 22G needles were 86.4% and 89.8%, respectively, with no significant difference (P = 0.180). Adverse events occurred in one patient. CONCLUSIONS: The 25G Franseen needle showed a noninferior adequate tissue acquisition and similar diagnostic performance compared to that of the 22G Franseen needle. However, a 15% noninferiority margin was high for clinical use; thus, further consideration is needed (Clinical Trial Registry no. UMIN000034596).


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas , Estudos Cross-Over , Endossonografia , Humanos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia
2.
Cancers (Basel) ; 16(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38927971

RESUMO

With the 12th highest incidence and a common late diagnostic at advanced stages, neoadjuvant therapies for pancreatic cancer are important, but they require a confirmed diagnosis. Being a diagnostic standard, the clarification of the clinical relevance of needle gauges is needed, as larger ones may retrieve more tissue for diagnostics, but may also increase the risk of complications. We performed a meta-analysis to compare the efficiency of the most commonly used 22-G and 25-G needles for EUS guided biopsy in solid pancreatic lesions. The MEDLINE (via PubMed), Embase, Cochrane (CENTRAL), and Scopus databases were searched with "EUS", "needle", "FNA", "pancreas", "prospective", "22G", and "25G" keywords. Mixed effects were assessed in the model, with a mean of 86% and a 95% confidence interval. Fourteen prospective studies that compared the efficiency of 22-G and 25-G biopsy needles in 508 and 524 lesions, respectively, were analyzed, along with 332 specimens biopsied using both needle sizes. The groups did not significantly differ in the outcomes. A low degree of heterogeneity was observed overall, except for specimen adequacy. Moreover, 22-G and 25-G needles have comparable safety and efficacy for focal pancreatic lesion biopsies without a high risk of complications.

3.
Int J Methods Psychiatr Res ; 33(2): e2027, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899465

RESUMO

OBJECTIVES: The 25-item Hikikomori Questionnaire (HQ-25) is an instrument developed to measure a condition characterized by extreme social withdrawal that was first described in Japan. This study aimed to translate the HQ-25 into German and validate the German version (HQ-25-G). METHODS: Translation was conducted according to established guidelines. Validation was based on data from a quota sample of individuals living in Germany, ranging from 18 to 74 years old (representing the distribution of age, sex and federal state, n = 5000). Data collection occurred during August and September 2023. We tested reliability, construct validity and concurrent validity. Moreover, HQ-25 scores for key sociodemographic group were reported. RESULTS: Internal reliability for the HQ-25-G was excellent (Cronbach's alpha = 0.93). We confirmed the original three-factor model. Moreover, higher hikikomori levels were significantly associated with more depressive symptoms (r = 0.50), more anxiety symptoms (r = 0.45), higher loneliness levels (r = 0.56), higher levels of objective social isolation (r = -0.47), higher levels of perceived social isolation (r = 0.59) and a higher preference for solitude (r = 0.45). CONCLUSIONS: In a large population-based sample (including younger adults, middle-aged adults and older adults), the HQ-25-G version proves to be a psychometrically robust instrument, which is useful for further exploring the phenomenon of hikikomori within the German-speaking population.


Assuntos
Psicometria , Isolamento Social , Humanos , Pessoa de Meia-Idade , Adulto , Masculino , Feminino , Idoso , Adulto Jovem , Adolescente , Alemanha , Reprodutibilidade dos Testes , Psicometria/normas , Depressão/diagnóstico , Ansiedade/diagnóstico , Escalas de Graduação Psiquiátrica/normas , Solidão , Inquéritos e Questionários/normas , Traduções
4.
Technol Health Care ; 32(2): 1099-1110, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37840508

RESUMO

BACKGROUND: The correlation between the change in foveal thickness measured using optical coherence tomography (OCT) following surgery for infectious endophthalmitis and preoperative and postoperative visual acuity is uncertain, and there are few pertinent studies on this topic. OBJECTIVE: We explored the variations in macular thickness using OCT after emergency vitrectomy for post-cataract infectious endophthalmitis and the relationship between macular thickness with changes in visual function. METHODS: We included 10 cases of post-cataract infectious endophthalmitis. Each patient underwent 25-G vitrectomy. RESULTS: The infection in all 10 patients was under control and visual function improved. Postoperative vitreous humor culture was positive in 8 patients, including 7 cases of coagulase-negative Staphylococcus epidermidis and 1 case of Lactobacillus acidophilus. The average age of these 10 patients was 71.60 ± 8.71 years (P< 0.05, two-tailed). There was no significant correlation between time 2 (the time of onset after cataract surgery) and visual prognosis. The average time 1 (the time of the vitrification surgery caused by the onset of the disease) was 1.45 ± 0.76 days (P< 0.05, two-tailed). The postoperative 3dVA ranged from 0.20 to 3.00, with an average visual acuity of 1.87 ± 1.12, which was superior to the preoperative value (P< 0.01, two-tailed). The correlation between the post3dVA and post 1mVA was significant. The post 1mVA ranged from 0.05 to 2.20, with an average visual acuity of 0.94 ± 0.74 (P< 0.05, two-tailed). The correlation between post 1mVA and post3mVA was significant. Also, paired t-tests comparing preoperative and postoperative visual acuity revealed a significant correlation (P< 0.05, two-tailed). The post3mVA was 0-1.00 with an average visual acuity of 0.44 ± 0.41. The postoperative foveal thickness ranged from 176.00 to 514.00 µm, with an average thickness of 281.10 ± 113.12 µm. CONCLUSION: Emergency 25-G minimally invasive vitrectomy can improve visual acuity and decrease the reoperation rate for patients who have acquired post-cataract infectious endophthalmitis. There were significant correlations between age, disease onset to operation time, preoperative and postoperative visual acuity, and postoperative macular thickness.


Assuntos
Catarata , Endoftalmite , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Vitrectomia/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias , Endoftalmite/cirurgia , Endoftalmite/etiologia , Catarata/complicações
5.
Sci Technol Adv Mater ; 14(1): 014206, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27877554

RESUMO

After a short review of electron tomography techniques for materials science, this overview will cover some recent results on different shape memory and nanostructured metallic systems obtained by various three-dimensional (3D) electron imaging techniques. In binary Ni-Ti, the 3D morphology and distribution of Ni4Ti3 precipitates are investigated by using FIB/SEM slice-and-view yielding 3D data stacks. Different quantification techniques will be presented including the principal ellipsoid for a given precipitate, shape classification following a Zingg scheme, particle distribution function, distance transform and water penetration. The latter is a novel approach to quantifying the expected matrix transformation in between the precipitates. The different samples investigated include a single crystal annealed with and without compression yielding layered and autocatalytic precipitation, respectively, and a polycrystal revealing different densities and sizes of the precipitates resulting in a multistage transformation process. Electron tomography was used to understand the interaction between focused ion beam-induced Frank loops and long dislocation structures in nanobeams of Al exhibiting special mechanical behaviour measured by on-chip deposition. Atomic resolution electron tomography is demonstrated on Ag nanoparticles in an Al matrix.

6.
Materials (Basel) ; 16(12)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37374645

RESUMO

The microstructure and room temperature tensile properties of heat-treated TC25G alloy after thermal exposure were investigated. The results show that the α2 phase dispersed in the α phase, and silicide precipitated firstly at the α/ß phase boundary and then at the dislocation of the αp phase and on the ß phase. When thermal exposure was 0-10 h at 550 °C and 600 °C, the decrease of alloy strength was mainly due to the dominant effect of dislocations recovery. With the rise and extension of thermal exposure temperature and time, the increasing quantity and size of precipitates played an important role in the improvement of alloy strength. When thermal exposure temperature rose to 650 °C, the strength was always lower than that of heat-treated alloy. However, since the decreasing rate of solid solution strengthening was smaller than the increasing rate of dispersion strengthening, alloy still showed an increasing trend in the range of 5-100 h. When thermal exposure time was 100-500 h, the size of the α2 phase increased from the critical value of 3 nm to 6 nm, and the interaction between the moving dislocations and the α2 phase changed from the cutting mechanism to the by-pass mechanism (Orowan mechanism), and thus alloy strength decreased rapidly.

7.
Case Rep Ophthalmol ; 13(1): 220-226, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35611013

RESUMO

We reported a case of simultaneous vitrectomy and sclerokeratoplasty (SKP) performed for keratoglobus with extensive corneal rupture and intraocular hemorrhage caused by trauma. A 73-year-old woman was treated for keratoglobus and glaucoma. She was punched in both eyes, her right eye showed corneal rupture and the left eye showed prolapse of the ocular contents due to eyeball rupture. She immediately underwent corneal sutures in the right eye and resection of the prolapsed ocular contents in the left eye at a nearby ophthalmological clinic. Three days after the injury, the patient was referred to our clinic for vision recovery. The best corrected visual acuity of the right eye was measured by counting fingers. Her right eye presented severe corneal edema with a sutured corneal wound in the upper periphery, which was positive in the Seidel test. B-mode ultrasound revealed choroidal detachment and subchoroidal hemorrhage. Fourteen days after injury, simultaneous corneal suture and posterior sclerotomy were performed in the right eye, but corneal fragility and corneal opacity were prominent, and B-mode examination revealed prolonged vitreous hemorrhage and retinal detachment. Twenty-one days after injury, we performed simultaneous SKP and 25-G pars plana vitrectomy (PPV). In this procedure, we initially performed SKP followed by 25-G PPV without a keratoprosthesis or endoscope. The visibility of the fundus through the corneoscleral graft was good during vitrectomy. Three months after surgery, her corrected visual acuity improved to 10/1,000. Although there was mild corneal stromal edema and khodadoust line, there were no obvious fundus complications. Simultaneous SKP and PPV for keratoglobus with extensive corneal rupture and vitreous diseases may be a good option.

8.
Ophthalmologe ; 119(2): 176-180, 2022 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-34297191

RESUMO

BACKGROUND: With the surgical methods continuously developed in recent years, macular surgery has become an increasingly less traumatic procedure for the eye. For patients with additional lens opacification, a 1-stage procedure with combined cataract surgery is recommended. OBJECTIVE: The aim of this retrospective study was to record the functional results and complications after elective macular surgery with and without combined phacoemulsification and artificial lens implantation. MATERIAL AND METHODS: The retrospective study included all patients who were operated on with a pars plana vitrectomy (ppV; 25 gauge) for epiretinal membrane, macular hole or vitreoretinal traction between 2010 and 2016 and who had a follow-up period of at least 3 months. The functional results and possible risk factors as well as complications that occurred were then recorded. RESULTS: A total of 781 eyes were identified of which 517 (66%) had a phacoemulsification and artificial lens implantation with a 25-gauge vitrectomy, membranectomy, ILM peeling and SF6 gas or air tamponade. The mean follow-up time was 17 months. The mean logMAR visual acuity was 0.59 preoperatively and 0.4 postoperatively. From 64 phacic eyes which did not receive a combined phacoemulsification and artificial lens implantation 40 (62.5%) required phacoemulsification and artificial lens implantation within 13.6 months due to complicated cataract, 18 even within 6 months. In terms of complications, there were comparable results between ppV alone and the combined operation, particularly with respect to an IOL dislocation or iris capture. CONCLUSION: Overall elective macular surgery is a procedure with few complications both without and above all with combined phacoemulsification and artificial lens implantation. Therefore, a combined operation makes sense in terms of surgical management and postoperative rehabilitation, especially in times of a pandemic with limited surgical resources.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Catarata/complicações , Humanos , Implante de Lente Intraocular , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Vitrectomia
9.
Sci Total Environ ; 842: 156828, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-35760181

RESUMO

The BiOCl0.75I0.25/g-C3N4 nanosheet (BCI-CN) was successfully immobilized on polyolefin polyester fiber (PPF) through the hydrothermal method. The novel immobilized BiOCl0.75I0.25/g-C3N4 nanocomposites (BCI-CN-PPF) were characterized by scanning electron microscope (SEM), energy dispersive spectroscopy EDS, X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and UV-vis diffuse reflectance spectroscopy (UV-vis DRS) to confirm that BCI-CN was successfully immobilized on PPF with abundant oxygen vacancies reserved. Under simulated solar light irradiation, 100 % of bisphenol A (BPA) with an initial concentration of 10 mg·L-1 was degraded by BCI-CN-PPF (0.2 g·L-1 of BCI-CN immobilized) after 60 min. A similar photocatalytic efficiency of BPA was obtained in the presence of effluent organic matter (EfOM). The photocatalytic degradation of BPA was not affected by EfOM <5 mg-C/L. In comparison, the photocatalytic performance was considerably inhibited by EfOM with a concentration of 10 mg-C/L. Furthermore, photogenerated holes and superoxide radicals predominated in the photocatalytic degradation processes of BPA. The total organic carbon (TOC) removal efficiencies of BPA and EfOM were 75.2 % and 50 % in the BCI-CN-PPF catalytic system. The BPA removal efficiency of 94.9 % was still achieved in the eighth cycle of repeated use. This study provides a promising immobilized nanocomposite with high photocatalytic activity and excellent recyclability and reusability for practical application in wastewater treatment.


Assuntos
Luz , Nanocompostos , Compostos Benzidrílicos/química , Catálise , Nanocompostos/química , Fenóis/química
10.
Endosc Ultrasound ; 10(1): 57-61, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33402551

RESUMO

BACKGROUND AND OBJECTIVES: The aim of the study was to perform the first randomized trial comparing the diagnostic yield, bloodiness, and cellularity of the 25G standard needle (25S) and the 25G ProCore™ needle (25P). MATERIALS AND METHODS: All patients referred to the tertiary care referral center for EUS guided fine-needle aspiration (EUS-FNA) of suspicious solid pancreatic lesions were eligible. EUS-FNA was performed in each lesion with both 25S and 25P needles (the choice of the first needle was randomized), using a multipass sampling pattern, without stylet or suction. Rapid on-site evaluation was used when possible. Pap-stained slides were read by a single experienced cytopathologist, blinded to the needle type. RESULTS: One hundred and forty-three patients were recruited. Samples were positive for cancer in 122/143 (85.3%) with the 25S needle versus 126/143 (88.1%) with the 25P needle, negative in 17/143 (11.9%) with the 25S needle versus 13/143 (9.1%) with the 25P needle, and suspicious in 4/143 (2.8%) with each needle. There was no difference in any outcome based on the type of the first needle. No carryover effect was detected (P = 0.214; NS). Cumulative logistic regression analyses showed no associations between the type of needle and diagnostic yield for cancer, cellularity, or bloodiness. The difference in the yield for cancer was 2.9% (-4.2; 10.1%); with the confidence interval upper within the predetermined noninferiority margin of 15%. CONCLUSION: The 25S needle is noninferior to the 25P needle for diagnosing cancer in suspicious pancreatic lesions.

11.
Int J Food Microbiol ; 352: 109267, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34102464

RESUMO

The use of bacteriocins is a promising alternative to improve food security through the biocontrol of food pathogens and spoilage microorganisms. Gram-negative produced microcin J25(G12Y), known as (MccJ25(G12Y)) is a variant of the well-studied and characterized antimicrobial peptide, microcin J25 (MccJ25). In the present work, we explored the activity of this microcin against Gram-negative bacteria linked to foodborne diseases. We evaluated the in vitro antimicrobial activity of MccJ25(G12Y) in solid medium against a collection of pathogenic and food-altering strains and studied its activity and stability in meat and dairy food systems. We show that MccJ25(G12Y) exhibited the same in vitro antimicrobial spectrum as its parental microcin (MccJ25) against different Gram-negative foodborne pathogens and spoilage strains. We highlight that low concentrations of MccJ25(G12Y) between 0.45 and 29.4 µM were able to inhibit a substantial number of pathogens, including Salmonella, Escherichia, Shigella and Enterobacter genus. We also demonstrate the antimicrobial effectiveness of the peptide against Escherichia coli O157:H7 NCTC 12900, Enterobacter cloacae CECT 194, and Salmonella enterica CECT 4396 in fish and beef burgers and yogurt. MccJ25(G12Y) was added or not to food matrices inoculated with the foodborne pathogens at 105 CFU/g or mL. Afterward, food products were stored at 4 °C and selective media for the specific enumeration were used to determine the antimicrobial susceptibility of each pathogen to MccJ25(G12Y). The viability of the three pathogens was significantly reduced in the different food biological environments. In yogurt, the peptide decreased E. coli numbers on day 5 by about 4 log 10 CFU/mL as compared to non-treated samples. For S. enterica and E. cloacae no viable cells were detected at the end of the treatment. Adding MccJ25(G12Y) to fish burgers decreased E. cloacae numbers during storage 2 log10 CFU/g on the first day, reaching a difference of about 5 log 10 CFU/g after 10 days compared to non-treated control. Finally, the peptide decreased E. coli O157:H7 numbers on the beef burgers samples during storage on day 10 by about 3 log 10 CFU/g as compared to non-treated samples. The stability analysis demonstrated that MccJ25(G12Y) is capable of remaining active in these food matrices for a considerable time during the storage at refrigeration temperatures. These results reinforce the studies on the potential applicability of this microcin as a biopreservative in the food industry.


Assuntos
Bacteriocinas/farmacologia , Manipulação de Alimentos/métodos , Microbiologia de Alimentos , Bactérias Gram-Negativas/efeitos dos fármacos , Animais , Antibacterianos/farmacologia , Contagem de Colônia Microbiana , Escherichia coli O157/efeitos dos fármacos , Doenças Transmitidas por Alimentos/microbiologia , Doenças Transmitidas por Alimentos/prevenção & controle , Salmonella/efeitos dos fármacos
12.
Case Rep Ophthalmol ; 11(1): 127-136, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32308614

RESUMO

We evaluated the visual outcome of combined penetrating keratoplasty (PKP) and 25G pars plana vitrectomy (PPV) performed without a temporary keratoprosthesis or endoscopy in a patient with vitreoretinal disease complicated by severe corneal opacity. The patient was a 68-year-old woman who had severe corneal opacity and silicone oil in her left eye after several previous intraocular surgeries for rhegmatogenous retinal detachment and proliferative vitreoretinopathy. We successfully performed a combined surgery of conventional PKP followed by 25G PPV without the use of a keratoprosthesis. At 6 months after surgery, visual acuity had not improved, and the density of corneal endothelial cells of the donor cornea had declined from 3,205 to 1,969 cells/mm2. However, corneal transparency remained good, and additional surgery for vitreoretinal disease was not necessary. The combined surgical procedure designed to minimize the number of open-sky steps and to limit vitreoretinal complications thus proved to be safe and achieved stable corneal clarity in a patient with vitreoretinal disease and severe corneal opacity.

13.
J Nutr Sci ; 9: e29, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32742646

RESUMO

Resistant maltodextrin (RMD) from various sources of starch has been extensively studied. However, studies which reported the effects of tapioca RMD (TRM) on glucose and insulin response are lacking. This study investigated the effect of TRM on postprandial plasma glucose and serum insulin in healthy subjects. Additionally, satiety and gastrointestinal tolerability were also evaluated. Sixteen healthy participants received five different treatments on five separate days. Participants received 50 g of either: glucose (GL), tapioca maltodextrin (TM), TRM, MIX15% (7⋅5 g TRM + 42⋅5 g TM) or MIX50% (25 g TRM + 25 g TM). Plasma glucose, serum insulin and subjective appetite responses were measured postprandially over 180 min. Gastrointestinal symptoms were evaluated by questionnaire before and after each test day. Results showed that at 30 min after treatment drinks, plasma glucose after TRM was significantly lowest (104⋅60 (sem 2⋅63 mg/dl) than after GL (135⋅87 (sem 4⋅88) mg/dl; P <0⋅001), TM (127⋅93 (sem 4⋅05) mg/dl; P = 0⋅001), MIX15% (124⋅67 (sem 5⋅73) mg/dl; P = 0⋅039) and MIX50% (129⋅33 (sem 5⋅23) mg/dl; P = 0⋅003) (1 mg/dl = 0⋅0555 mmol/l). In addition, TRM also significantly reduced serum insulin (13⋅01 (sem 2⋅12) µIU/ml) compared with GL (47⋅90 (sem 11⋅93) µIU/ml; P = 0⋅013), TM (52⋅96 (sem 17⋅68) µIU/ml; P = 0⋅002) and MIX50% (33⋅16 (sem 4⋅99) µIU/ml; P = 0⋅008). However, there were no significant differences in subjective appetite between treatments (P > 0⋅05). A single high dose of TRM (50 g) caused flatulence (P < 0⋅05). Tapioca resistant maltodextrin has low digestibility in the small intestine and, therefore, reduced incremental plasma glucose and serum insulin, without affecting satiety in healthy subjects over 180 min. Gastrointestinal tolerability of TRM should be considered when consumed in high doses.


Assuntos
Glicemia/efeitos dos fármacos , Dieta , Insulina/sangue , Manihot , Polissacarídeos/farmacologia , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Polissacarídeos/administração & dosagem , Período Pós-Prandial , Inquéritos e Questionários , Resultado do Tratamento , Adulto Jovem
14.
Clin Ophthalmol ; 12: 313-317, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29491704

RESUMO

PURPOSE: To introduce a hybrid wide-angle viewing-endoscopic vitrectomy, which we have reported, using a 3D visualization system developed recently. SUBJECTS AND METHODS: We report a single center, retrospective, consecutive surgical case series of 113 eyes that underwent 25 G vitrectomy (rhegmatogenous retinal detachment or proliferative vitreoretinopathy, 49 eyes; epiretinal membrane, 18 eyes; proliferative diabetic retinopathy, 17 eyes; vitreous opacity or vitreous hemorrhage, 11 eyes; macular hole, 11 eyes; vitreomacular traction syndrome, 4 eyes; and luxation of intraocular lens, 3 eyes). RESULTS: This system was successfully used to perform hybrid vitrectomy in the difficult cases, such as proliferative vitreoretinopathy and proliferative diabetic retinopathy. CONCLUSION: Hybrid wide-angle viewing-endoscopic vitrectomy using a 3D visualization system appears to be a valuable and promising method for managing various types of vitreo-retinal disease.

15.
Oman J Ophthalmol ; 10(3): 213-219, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29118498

RESUMO

PURPOSE: To compare the clinical outcomes and complications between 23-G and 25-G vitrectomy in patients with diabetic vitreous hemorrhage (VH). MATERIALS AND METHODS: A retrospective comparative study comprising 69 eyes (36 eyes in 23-G group and 33 eyes in 25-G group) of 65 patients who underwent vitrectomy with air tamponade for diabetic vitreous hemorrhage (VH) with at least 6 months of follow-up was conducted. RESULTS: There were no significant differences between the two groups in age, gender, bilaterality, type of diabetes, presence of hypertension, lens status, and previous argon laser photocoagulation state (P > 0.05). Best-corrected visual acuity (BCVA) of both groups at postoperative 1 month logarithm of the minimum angle of resolution (logMAR) (1.06 ± 0.99, 0.90 ± 0.96), 3 months logMAR (1.07 ± 0.93, 0.83 ± 0.85), and 6 months logMAR (1.03 ± 0.89, 0.83 ± 0.85) significantly improved from the preoperative BCVA logMAR (2.03 ± 0.83, 2.15 ± 0.99) for 23-G group, 25-G group, respectively (P < 0.0001). There was no significant difference in BCVA between the two groups preoperatively and at 1, 3, and 6 months postoperatively (P = 0.566, 0.506, 0.333, and 0.445, respectively), incidence of intraoperative wound suturing (21.4%, 15.2%), postoperative hypotony (0.0%, 0.0%), early postoperative VH (POVH) (11.1%, 15.2%), late POVH (5.6%, 0.0%), retinal detachment (2.8%, 6.1%), neovascular glaucoma (92.8%, 9.1%), and endophthalmitis (0.0%, 0.0%) for 23-G group, 25-G group, respectively (P > 0.05). CONCLUSION: 25-G vitrectomy is as effective for PDR as 23-G vitrectomy.

16.
Exp Ther Med ; 14(2): 1193-1197, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28810578

RESUMO

The aim of the present study was to compare the effectiveness of 25G vitrectomy to standard 20G vitrectomy for treatment of Terson syndrome under Resight non-contact wide-angle lenses. This was a case-control study of 20 patients with Terson syndrome (study group) that underwent 25G vitrectomy under Resight non-contact wide-angle lenses, with those of 20 matched patients that underwent 20G vitrectomy (control group). Medical records were reviewed from between July 2011 and October 2013. Data included results of the Early Treatment Diabetic Retinopathy Study examination, ophthalmology B-scan ultrasonography and fundus photography. The mean age, follow-up time, the preoperative visual acuity of LogMAR and the preoperative intraocular pressure (IOP) were all comparable in the two groups (all P>0.05). There were statistically significant differences in postoperative visual acuity of LogMAR compared with preoperative visual acuity (P<0.001) in both groups, but no difference between the groups (P=0.845). However, the operative times (13.5 min in study group vs. 42 min in control group) and post-operative IOP at day 1 (13.5 vs. 20 mmHg) were significantly reduced in the study group compared to the control group (P<0.001). Therefore, the present findings suggest that 25G Vitrectomy for Terson syndrome under Resight non-contact wide-angle lenses can achieve a significantly shorter operative time and lower post-operative IOP compared with 20G Vitrectomy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA