Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Hippocampus ; 34(6): 302-308, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38593279

RESUMO

Researchers who study the human hippocampus are naturally interested in how its subfields function. However, many researchers are precluded from examining subfields because their manual delineation from magnetic resonance imaging (MRI) scans (still the gold standard approach) is time consuming and requires significant expertise. To help ameliorate this issue, we present here two protocols, one for 3T MRI and the other for 7T MRI, that permit automated hippocampus segmentation into six subregions, namely dentate gyrus/cornu ammonis (CA)4, CA2/3, CA1, subiculum, pre/parasubiculum, and uncus along the entire length of the hippocampus. These protocols are particularly notable relative to existing resources in that they were trained and tested using large numbers of healthy young adults (n = 140 at 3T, n = 40 at 7T) whose hippocampi were manually segmented by experts from MRI scans. Using inter-rater reliability analyses, we showed that the quality of automated segmentations produced by these protocols was high and comparable to expert manual segmenters. We provide full open access to the automated protocols, and anticipate they will save hippocampus researchers a significant amount of time. They could also help to catalyze subfield research, which is essential for gaining a full understanding of how the hippocampus functions.


Assuntos
Hipocampo , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Hipocampo/diagnóstico por imagem , Masculino , Adulto , Feminino , Adulto Jovem , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Reprodutibilidade dos Testes
2.
Magn Reson Med ; 91(1): 39-50, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796151

RESUMO

PURPOSE: To explore the potential of 3T deuterium metabolic imaging (DMI) using a birdcage 2 H radiofrequency (RF) coil in both healthy volunteers and patients with central nervous system (CNS) lesions. METHODS: A modified gradient filter, home-built 2 H volume RF coil, and spherical k-space sampling were employed in a three-dimensional chemical shift imaging acquisition to obtain high-quality whole-brain metabolic images of 2 H-labeled water and glucose metabolic products. These images were acquired in a healthy volunteer and three subjects with CNS lesions of varying pathologies. Hardware and pulse sequence experiments were also conducted to improve the signal-to-noise ratio of DMI at 3T. RESULTS: The ability to quantify local glucose metabolism in correspondence to anatomical landmarks across patients with varying CNS lesions is demonstrated, and increased lactate is observed in one patient with the most active disease. CONCLUSION: DMI offers the potential to examine metabolic activity in human subjects with CNS lesions with DMI at 3T, promising for the potential of the future clinical translation of this metabolic imaging technique.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Deutério , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Razão Sinal-Ruído , Glucose
3.
Skeletal Radiol ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607418

RESUMO

OBJECTIVE: To compare image quality and diagnostic performance of 3T and 7T magnetic resonance imaging (MRI) for direct depiction of finger flexor pulleys A2, A3 and A4 before and after artificial pulley rupture in an ex-vivo model using anatomic preparation as reference. MATERIALS AND METHODS: 30 fingers from 10 human cadavers were examined at 3T and 7T before and after being subjected to iatrogenic pulley rupture. MRI protocols were comparable in duration, both lasting less than 22 min. Two experienced radiologists evaluated the MRIs. Image quality was graded according to a 4-point Likert scale. Anatomic preparation was used as gold standard. RESULTS: In comparison, 7T versus 3T had a sensitivity and specificity for the detection of A2, A3 and A4 pulley lesions with 100% vs. 95%, respectively 98% vs. 100%. In the assessment of A3 pulley lesions sensitivity of 7T was superior to 3T MRI (100% vs. 83%), whereas specificity was lower (95% vs. 100%). Image quality assessed before and after iatrogenic rupture was comparable with 2.74 for 7T and 2.61 for 3T. Visualization of the A3 finger flexor pulley before rupture creation was significantly better for 7 T (p < 0.001). Interobserver variability showed substantial agreement at 3T (κ = 0.80) and almost perfect agreement at 7T (κ = 0.90). CONCLUSION: MRI at 3T allows a comparable diagnostic performance to 7T for direct visualization and characterization of finger flexor pulleys before and after rupture, with superiority of 7T MRI in the visualization of the normal A3 pulley.

4.
Int J Mol Sci ; 25(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38673818

RESUMO

Traumatic brain injury (TBI) significantly contributes to death and disability worldwide. However, treatment options remain limited. Here, we focus on a specific pathology of TBI, diffuse axonal brain injury (DABI), which describes the process of the tearing of nerve fibers in the brain after blunt injury. Most protocols to study DABI do not incorporate a specific model for that type of pathology, limiting their ability to identify mechanisms and comorbidities of DABI. In this study, we developed a magnetic resonance imaging (MRI) protocol for DABI in a rat model using a 3-T clinical scanner. We compared the neuroimaging outcomes with histologic and neurologic assessments. In a sample size of 10 rats in the sham group and 10 rats in the DABI group, we established neurological severity scores before the intervention and at 48 h following DABI induction. After the neurological evaluation after DABI, all rats underwent MRI scans and were subsequently euthanized for histological evaluation. As expected, the neurological assessment showed a high sensitivity for DABI lesions indicated using the ß-APP marker. Surprisingly, however, we found that the MRI method had greater sensitivity in assessing DABI lesions compared to histological methods. Out of the five MRI parameters with pathological changes in the DABI model, we found significant changes compared to sham rats in three parameters, and, as shown using comparative tests with other models, MRI was the most sensitive parameter, being even more sensitive than histology. We anticipate that this DABI protocol will have a significant impact on future TBI and DABI studies, advancing research on treatments specifically targeted towards improving patient quality of life and long-term outcomes.


Assuntos
Lesão Axonal Difusa , Modelos Animais de Doenças , Imageamento por Ressonância Magnética , Animais , Imageamento por Ressonância Magnética/métodos , Ratos , Masculino , Lesão Axonal Difusa/diagnóstico por imagem , Lesão Axonal Difusa/patologia , Ratos Sprague-Dawley , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Lesões Encefálicas Traumáticas/patologia
5.
Neuroimage ; 271: 120011, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36914107

RESUMO

INTRODUCTION: Functional MRI with spatial resolution in the submillimeter domain enables measurements of activation across cortical layers in humans. This is valuable as different types of cortical computations, e.g., feedforward versus feedback related activity, take place in different cortical layers. Laminar fMRI studies have almost exclusively employed 7T scanners to overcome the reduced signal stability associated with small voxels. However, such systems are relatively rare and only a subset of those are clinically approved. In the present study, we examined if the feasibility of laminar fMRI at 3T could be improved by use of NORDIC denoising and phase regression. METHODS: 5 healthy subjects were scanned on a Siemens MAGNETOM Prisma 3T scanner. To assess across-session reliability, each subject was scanned in 3-8 sessions on 3-4 consecutive days. A 3D gradient echo EPI (GE-EPI) sequence was used for BOLD acquisitions (voxel size 0.82 mm isotopic, TR = 2.2 s) using a block design finger tapping paradigm. NORDIC denoising was applied to the magnitude and phase time series to overcome limitations in temporal signal-to-noise ratio (tSNR) and the denoised phase time series were subsequently used to correct for large vein contamination through phase regression. RESULTS AND CONCLUSION: NORDIC denoising resulted in tSNR values comparable to or higher than commonly observed at 7T. Layer-dependent activation profiles could thus be extracted robustly, within and across sessions, from regions of interest located in the hand knob of the primary motor cortex (M1). Phase regression led to substantially reduced superficial bias in obtained layer profiles, although residual macrovascular contribution remained. We believe the present results support an improved feasibility of laminar fMRI at 3T.


Assuntos
Mãos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Extremidade Superior , Mapeamento Encefálico/métodos , Encéfalo
6.
MAGMA ; 36(1): 15-23, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36166103

RESUMO

OBJECTIVE: Recent work showed the feasibility of measuring velocity pulsatility in the perforating arteries at the level of the BG using 3T MRI. However, test-retest measurements have not been performed, yet. This study assessed the test-retest reliability of 3T MRI blood flow velocity measurements in perforating arteries in the BG. MATERIALS AND METHODS: Two-dimensional phase-contrast cardiac gated (2D-PC) images were acquired for 35 healthy controls and repeated with and without repositioning. 2D-PC images were processed and analyzed, to assess the number of detected perforating arteries (Ndetected), mean blood flow velocity (Vmean), and velocity pulsatility index (vPI). Paired t-tests and Bland-Altman plots were used to compare variance in outcome parameters with and without repositioning, and limits of agreement (LoA) were calculated. RESULTS: The LoA was smallest for Vmean (35%) and highest for vPI (79%). Test-retest reliability was similar with and without repositioning of the subject. DISCUSSION: We found similar LoA with and without repositioning indicating that the measurement uncertainty is dominated by scanner and physiological noise, rather than by planning. This enables to study hemodynamic parameters in perforating arteries at clinically available scanners, provided sufficiently large sample sizes are used to mitigate the contribution of scanner- and physiological noise.


Assuntos
Hemodinâmica , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Gânglios da Base
7.
Pediatr Radiol ; 53(6): 1085-1091, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36823375

RESUMO

BACKGROUND: The utilization of 3-T magnetic field strength in obstetric imaging is increasingly common. It is important to ensure that magnetic resonance (MR) imaging with higher magnetic field strength is safe for the fetus. Comparison of neurodevelopmental outcome in neonates undergoing prenatal MR imaging with 1.5-T versus 3-T is of interest but has not yet been examined. OBJECTIVE: We hypothesized no clinically meaningful difference in neurodevelopmental outcome between fetuses undergoing 1.5-T versus 3-T fetal MR imaging. As imaging a normal fetus for research purposes is illegal in Pennsylvania, this study was conducted in a population of fetuses with left congenital diaphragmatic hernia (left-CDH). MATERIALS AND METHODS: A retrospective review of neurodevelopmental outcome of fetuses with left-CDH scanned at 1.5-T (n=75) versus 3-T (n=25) magnetic field strength between July of 2012 and December of 2019 was performed. Neurodevelopmental outcomes were assessed using the Bayley Scales of Infant Development, 3rd Edition (BSID-III). RESULTS: There were no statistical differences in median age of assessment (1.5-T: 18 [12, 25] versus 3-T: 21 [11, 26], P=0.79), in mean BSID-III cognitive (1.5-T: 91 ± 14 versus 3-T: 90 ± 16, P=0.82), language (1.5-T: 92 ± 20 versus 3-T: 91 ± 20, P=0.91), and motor composite (1.5-T: 89 ± 15 versus 3-T: 87 ± 18, P=0.59) scores, subscales scores (for all, P>0.50), or in risk of abnormal neuromuscular exam (P=0.29) between neonates with left-CDH undergoing a 1.5-T versus 3-T MR imaging during fetal life. Additionally, the distribution of patients with average, mildly delayed, and severely delayed BSID-III scores was similar between the two groups (for all, P>0.50). The overall distribution of the composite scores in this CDH population was similar to the general population independent of exposure to 1.5-T or 3-T fetal MR imaging. Two 3-T patients (8%) and five 1.5-T patients (7%) scored within the significant delayed range for all BSID-III domains. Subjects with lower observed-to-expected fetal lung volume (O/E FLV) and postnatal need for ECMO had lower cognitive, language, motor, and subscales scores (for all, P<0.03) regardless of being imaged at 1.5-T versus 3-T. CONCLUSION: This preliminary study suggests that, compared to 1.5-T MR imaging, fetal exposure to 3-T MR imaging does not increase the risk of neurodevelopmental impairment in fetuses with left-CDH. Additional MR imaging studies in larger CDH cohorts and other fetal populations are needed to replicate and extend the present findings.


Assuntos
Hérnias Diafragmáticas Congênitas , Recém-Nascido , Lactente , Feminino , Criança , Humanos , Gravidez , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Feto/patologia , Medidas de Volume Pulmonar/métodos , Diagnóstico Pré-Natal/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Pulmão
8.
BMC Vet Res ; 18(1): 236, 2022 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-35733155

RESUMO

BACKGROUND: Lameness in cattle is a major health problem and causes great economic losses. Carpal injury is a common cause of forelimb lameness in cattle. Radiography and/or ultrasonography of the carpus is a challenge due to complex anatomy of the joint. Additional imaging using computed tomography (CT) or magnetic resonance imaging (MRI) may be indispensable for reaching a decisive diagnosis. Precise evaluation of the clinical CT and MRI images necessitates an in-depth knowledge of the normal CT and MRI tissue variants. Therefore, our purpose was to provide a detailed description of the normal CT and MRI appearance of the osseous and soft tissue structures of twelve cadaveric bovine carpi using CT and 3 Tesla MRI. Carpi were frozen, transected in sagittal, dorsal and transverse planes then adjoined to their corresponding CT and MRI images. RESULTS: The clinically significant articular and peri-articular structures of the bovine carpus were identified and characterized on the CT and MRI images. CT images provided a remarkable delineation of the cortical, subchondral, and cancellous bone. The high-field 3 Tesla MRI offered high definition and distinction of the delicate soft tissues of the bovine carpus. CONCLUSIONS: 3 Tesla high-field MRI offers new opportunities in soft tissue tomography but cannot be compared with CT in terms of bone imaging. Clinicians have to determine whether CT, MRI or both imaging techniques are required in clinical situations.


Assuntos
Carpo Animal , Bovinos , Imageamento por Ressonância Magnética , Animais , Carpo Animal/diagnóstico por imagem , Doenças dos Bovinos/diagnóstico por imagem , Humanos , Coxeadura Animal/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Radiografia , Tomografia Computadorizada por Raios X/veterinária , Ultrassonografia
9.
BMC Vet Res ; 18(1): 67, 2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35144606

RESUMO

BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic resonance imaging (HR-MRI) with ultrasound (US) and ultrasound biomicroscopy (UBM) in the normal canine eye, to assess its potential to depict normal ocular anatomy. RESULTS: HR-MRI was compared with US and UBM in 10 eyes from 10 healthy beagle dogs. Ocular structures (cornea, anterior chamber, iridocorneal angle, iris, lens, ciliary body, choroid, vitreous body, posterior wall of the eye, optic nerve and optic nerve sheath, extraocular muscles) were assessed subjectively and central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), anteroposterior, mediolateral and dorsoventral lens diameter (APLD, MLLD, DVLD), anteroposterior diameter of the globe including and excluding the scleroretinal rim (APDSRR, APD), vitreous chamber depth (VCD) and optic nerve sheath diameter (ONSD) were measured in HR-MRI and in US. Optic nerve diameter (OND) was measured in HR-MRI. HR-MRI and UBM appearance of the anterior segment were subjectively compared. Detailed reference high-resolution MRI images of normal eyes of Beagle dogs are provided. CONCLUSIONS: HR-MRI allowed assessment of all structures identified with US and UBM. The MRI examinations were performed under general anesthesia with the addition of a neuromuscular blocking agent, while US and UBM examinations were performed in conscious animals. Visibility of the entire ocular wall, the lens, the structures caudal to the ciliary body and the optic nerve and its sheath was superior with HR-MRI. HR-MRI allowed the distinction of retina, choroid and sclera, and the delineation of structures not previously identified in canine eyes with MRI, including Tenon's capsule and the sub-Tenon's space.Plane selection was more accurate with HR-MRI compared to US. In general, the range of measurements was narrower for MRI than for US. CCT, AQD, APLD, MLLD, APD, APDSRR and ONSD differed significantly between HR-MRI and US, respectively (p = 0.005-0.027).Micro-MRI may be useful for the assessment of ocular pathologies in the future.


Assuntos
Segmento Anterior do Olho , Microscopia Acústica , Animais , Segmento Anterior do Olho/anatomia & histologia , Segmento Anterior do Olho/diagnóstico por imagem , Córnea/anatomia & histologia , Cães , Imageamento por Ressonância Magnética/veterinária , Microscopia Acústica/métodos , Microscopia Acústica/veterinária , Ultrassonografia/veterinária
10.
Childs Nerv Syst ; 38(2): 379-386, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34613451

RESUMO

OBJECTIVES: To the best of our knowledge, there is no study on 3-Tesla (3-T) phase-contrast MRI (PC-MRI) and three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE-VFAM) in the evaluation of idiopathic scoliosis. This study aimed to investigate CSF abnormalities in the scoliotic spine using 3-T PC-MRI and 3D-SPACE-VFAM techniques. METHODS: Thirty-four patients and 14 controls were examined with spinal PC-MRI and T2-weighted 3D-SPACE-VFAM techniques. Inter- and intra-reader agreements of flow-void phenomenon on 3D-SPACE-VFAM images, and velocity values on PC-MRI data were also evaluated. RESULTS: There are statistically significant differences between scoliosis and control groups based on the highest and mean peak velocity values on PC-MRI images (p = 0.005 and p = 0.023, respectively). The main thoracic (MT) group's highest peak CSF velocity values were higher than the control group (p = 0.022). There is a significant difference between the patient and control groups regarding flow-void phenomenon scores on 3D-SPACE-VFAM images (p = 0.036). Inter- and intra-reader agreement values related to PC-MRI velocity measurements were perfect for all PC-MRI readings. Inter- and intra-reader agreement values of the flow-void phenomenon scores were moderate. CONCLUSIONS: Our study has led us to conclude that idiopathic scoliosis is associated with CSF flow disturbances in parallel with the literature. MRI can demonstrate these abnormalities in a non-invasive and radiation-free way.


Assuntos
Escoliose , Meios de Contraste , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Escoliose/diagnóstico por imagem , Coluna Vertebral
11.
Pediatr Radiol ; 52(5): 959-970, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35147713

RESUMO

BACKGROUND: The Fetal Imaging Taskforce was established in 2018 by the European Society of Paediatric Radiology. The first survey on European practice of fetal imaging published in 2020 revealed that 30% of fetal magnetic resonance imaging (MRI) is performed at 3 tesla (T). The purpose of this second survey was to identify the impact of 3-T fetal MRI with an emphasis on image quality, diagnostic yield, and technical challenges and artifacts at higher field strengths. OBJECTIVE: To describe the prenatal imaging practice at 3-T MRI units in various centres in Europe and to prepare recommendations on behalf of the Fetal Imaging Taskforce. MATERIALS AND METHODS: A survey was sent to all members performing 3-T fetal MRI. Questions included practitioner experience, magnet brand, protocols, counselling, artifacts and benefits of imaging at higher field strengths. RESULTS: Twenty-seven centres replied and reported improved spatial resolution and improved signal-to-noise ratio when performing fetal MRI at 3 T. Shading and banding artifacts and susceptibility to motion artifacts were common problems identified by practitioners at the higher field strength. For all neurological indications, practitioners reported a benefit of imaging at 3 T, most marked for posterior fossa evaluation and parenchymal lesions. CONCLUSION: The use of 3-T magnets in fetal MRI has improved the availability and quality of advanced imaging sequences and allowed for better anatomical evaluation. There remain significant challenges to minimize the impact of artifacts on image quality. This paper includes guidelines for clinical practice and imaging at 3 T.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Criança , Feminino , Feto/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Gravidez , Razão Sinal-Ruído
12.
Radiol Med ; 127(6): 645-651, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35366709

RESUMO

Vessel Wall MRI (VW-MRI) is an emerging MR sequence used for diagnosis, characterization, and treatment planning of cerebrovascular diseases. Although VW-MRI is not yet routinely used, most papers have emphasized its role in several aspects of the management of cerebrovascular diseases. Nowadays, no VW-MRI sequence optimized for the intracranial imaging is commercially available, thus the Spin Echo sequences are the more effective sequences for this purpose. Moreover, as one of the principal technical requirements for intracranial VW-MR imaging is to achieve both the suppression of blood in vessel lumen and of the outer cerebrospinal fluid, different suppression techniques have been developed. This short report provides the technical parameters of our VW-MR sequence developed over 3-years' experience.


Assuntos
Transtornos Cerebrovasculares , Imageamento por Ressonância Magnética , Transtornos Cerebrovasculares/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos
13.
Turk J Med Sci ; 52(6): 1943-1949, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36945976

RESUMO

BACKGROUND: We investigated the diagnostic values and artifact severities of 3D-T1W sequences in the diagnosis of cerebrospinal fluid (CSF) leakage. METHODS: We retrospectively reviewed 3-tesla contrast-material enhanced MR cisternography exams of 22 patients with suspected CSF leakage in 4 years. The presence of the artifacts on 3D-T1W data was evaluated using a 4-point scale (0: none; 1: minimal; 2: moderate; 3: prominent). Agreements between CSF leakage results of the 3D-T1W sequences and consensus decisions were evaluated via kappa values. Artifact scores were analyzed by Fisher's exact test. RESULTS: The most compatible techniques with the consensus diagnoses were fat-saturated 3D-T1W-SPACE and 3D-T1W-VIBE sequences. The most artifact containing the 3D-T1W sequence was 3D-MPRAGE. DISCUSSION: 3D-SPACE and 3D-VIBE are more successful in evaluating CSF leakages compared to 3D-MPRAGE. 3D-SPACE has lower artifact scores compared to 3D-VIBE and 3D-MPRAGE sequences.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Angiografia , Imageamento Tridimensional/métodos
14.
Magn Reson Med ; 85(4): 2016-2026, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33169877

RESUMO

PURPOSE: To demonstrate the feasibility of 3D multi-shot magnetic resonance imaging acquisitions for stimulus-evoked blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) in the human spinal cord in vivo. METHODS: Two fMRI studies were performed at 3T. The first study was a hypercapnic gas challenge where data were acquired from healthy volunteers using a multi-shot 3D fast field echo (FFE) sequence as well as single-shot multi-slice echo-planar imaging (EPI). In the second study, another cohort of healthy volunteers performed an upper extremity motor task while fMRI data were acquired using a 3D multi-shot acquisition. RESULTS: Both 2D-EPI and 3D-FFE were shown to be sensitive to BOLD signal changes in the cervical spinal cord, and had comparable contrast-to-noise ratios in gray matter. FFE exhibited much less signal drop-out and weaker geometric distortions compared to EPI. In the motor paradigm study, the mean number of active voxels was highest in the ventral gray matter horns ipsilateral to the side of the task and at the spinal level associated with innervation of finger extensors. CONCLUSIONS: Highly multi-shot acquisition sequences such as 3D-FFE are well suited for stimulus-evoked spinal cord BOLD fMRI.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Animais , Córtex Cerebral , Substância Cinzenta/diagnóstico por imagem , Humanos , Medula Espinal/diagnóstico por imagem
15.
Acta Derm Venereol ; 100(18): adv00317, 2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-32945342

RESUMO

Hidradenitis suppurativa has a substantial negative effect on quality of life of affected persons. Diagnosis is based mainly on clinical examination. However, physi-cal examination alone might underestimate disease severity compared with imaging modalities. We report here the application of non-contrast-enhanced 3-Tesla magnetic resonance imaging using surface-coil and sonography for assessment of hidradenitis suppurativa lesions based on topographic assessment of skin lesions. In addition, we review the literature regarding the application of ultrasound and magnetic resonance imaging in hidradenitis suppurativa.


Assuntos
Hidradenite Supurativa , Hidradenite Supurativa/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Qualidade de Vida , Índice de Gravidade de Doença , Ultrassonografia
16.
Magn Reson Med ; 82(2): 743-748, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30924198

RESUMO

PURPOSE: To measure the transverse relaxation time T2* in healthy human cervical spinal cord gray matter (GM) and white matter (WM) at 3T. METHODS: Thirty healthy volunteers were recruited. Axial images were acquired using an averaged multi-echo gradient-echo (mFFE) T2*-weighted sequence with 5 echoes. We used the signal equation for an mFFE sequence with constant dephasing gradients after each echo to jointly estimate the spin density and T2* for each voxel. RESULTS: No global difference in T2* was observed between all GM (41.3 ± 5.6 ms) and all WM (39.8 ± 5.4 ms). No significant differences were observed between left (43.2 ± 6.8 ms) and right (43.4 ± 5.5 ms) ventral GM, left (38.3 ± 6.1 ms) and right (38.6 ± 6.5 ms) dorsal GM, and left (39.4 ± 5.8 ms) and right (40.3 ± 5.8 ms) lateral WM. However, significant regional differences were observed between ventral (43.4 ± 5.7 ms) and dorsal (38.4 ± 6.0 ms) GM (p < 0.05), as well as between ventral (42.9 ± 6.5 ms) and dorsal (37.9 ± 6.2 ms) WM (p < 0.05). In analyses across slices, inferior T2* was longer than superior T2* in GM (44.7 ms vs. 40.1 ms; p < 0.01) and in WM (41.8 ms vs. 35.9 ms; p < 0.01). CONCLUSIONS: Significant differences in T2* are observed between ventral and dorsal GM, ventral and dorsal WM, and superior and inferior GM and WM. There is no evidence for bilateral asymmetry in T2* in the healthy cord. These values of T2* in the spinal cord are notably lower than most reported values of T2* in the cortex.


Assuntos
Substância Cinzenta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Medula Espinal/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Adulto Jovem
17.
Magn Reson Med ; 82(2): 825-832, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30900352

RESUMO

PURPOSE: To demonstrate a 1 H/31 P whole human brain volume coil configuration for 3 Tesla with separate 31 P transmit and receive components that maintains 1 H MRS performance and delivers optimal 31 P MRSI with 1 H decoupling. METHODS: We developed an 8-channel 31 P receive array coil covering the head to be used as an insert for a commercial double-tuned 1 H/31 P birdcage transmit-receive coil. This retains the possibility of using low-power rectangular pulses for 1 H-decoupled 3D 31 P MRSI (nominal resolution 17.6 cm3 ; acquisition duration 13 min) but increases the SNR with the receive sensitivity of 31 P surface coils. The performance of the combined coil setup was evaluated by measuring 1 H and 31 P SNR with and without the 31 P receive array and by assessing the effect of the receive array on the transmit efficiencies of the birdcage coil. RESULTS: Compared to the birdcage coil alone, the 31 P insert in combination with the birdcage achieved an average 31 P SNR gain of 1.4 ± 0.4 in a center partition of the brain. The insert did not cause losses in 1 H MRS performance and transmit efficiency, whereas for 31 P approximately 20% more power was needed to achieve the same γB1. CONCLUSION: The new coil configuration allows 1 H MRSI and optimal 1 H-decoupled 3D 31 P MRSI, with increased SNR of the human brain without patient repositioning, for clinical and research purposes at 3 Tesla.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Masculino , Imagens de Fantasmas
18.
Magn Reson Med ; 81(5): 3234-3244, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30474151

RESUMO

PURPOSE: To develop and evaluate an accelerated 3D self-gated cardiac cine imaging technique at 3 Tesla without the use of external electrocardiogram triggering or respiratory gating. METHODS: A 3D stack-of-stars balanced steady-state free precession sequence with a tiny golden angle sampling scheme was developed to reduced eddy current effect-related artefacts at 3 Tesla. Respiratory and cardiac motion were derived from a central 5-point self-gating signal extraction approach. The data acquired around the end-expiration phases were then sorted into individual cardiac bins and used for reconstruction with compressed sensing. To evaluate the performance of the proposed method, image quality (1: the best; 4: the worst) was quantitatively compared using both the proposed method and the conventional 3D golden-angle self-gated method. Linear regression and Bland-Altman analysis were used to assess the functional measurements agreement between the proposed method and the routine 2D breath-hold multi-slice technique. RESULTS: Compared to the conventional 3D golden-angle self-gated method, the proposed method yielded images with much less streaking artifact and higher myocardium edge sharpness (0.50 ± 0.06 vs. 0.45 ± 0.05, P = 0.004). The proposed method provided an inferior image quality score to the routine 2D technique (2.13 ± 0.35 vs. 1.38 ± 0.52, P = 0.063) but a superior one to the conventional self-gated method (2.13 ± 0.35 vs. 3.13 ± 0.64, P = 0.031). Left ventricular functional measurements between the proposed method and routine 2D technique were all well in agreement. CONCLUSION: This study presents a novel self-gating approach to realize rapid 3D cardiac cine imaging at 3 Tesla.


Assuntos
Suspensão da Respiração , Técnicas de Imagem de Sincronização Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Algoritmos , Artefatos , Feminino , Humanos , Modelos Lineares , Masculino , Respiração , Adulto Jovem
19.
Pediatr Radiol ; 49(1): 37-45, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30298210

RESUMO

BACKGROUND: Fetal MRI at 3 T is associated with increased acoustic noise relative to 1.5 T. OBJECTIVE: The goal of this study is to determine if there is an increased prevalence of congenital hearing loss in neonates who had a 3-T prenatal MR vs. those who had it at 1.5 T. MATERIALS AND METHODS: We retrospectively identified all subjects who had 3-T fetal MRI between 2012 and 2016 and also underwent universal neonatal hearing screening within 60 days of birth. Fetuses with incomplete hearing screening, magnetic resonance imaging (MRI) studies at both field strengths or fetuses affected by conditions associated with hearing loss were excluded. A random group of controls scanned at 1.5 T was identified. Five subjects had repeat same-strength MRIs (one at 3 T and four at 1.5 T). The pass/fail rate of the transient otoacoustic emissions test and auditory brainstem response test were compared using the Fisher exact test. A logistic regression was performed to assess the effects of other known risk factors for congenital hearing loss. RESULTS: Three hundred forty fetal MRI examinations were performed at 3 T, of which 62 met inclusion criteria. A control population of 1.5-T fetal MRI patients was created using the same exclusion criteria, with 62 patients randomly selected from the eligible population. The fail rates of transient otoacoustic emissions test for the 1.5-T and 3-T groups were 9.7% and 6.5%, respectively, and for the auditory brainstem response test were 3.2% and 1.6%, respectively. There was no significant difference in the fail rate of either test between groups (P=0.74 for transient otoacoustic emissions test, and P=0.8 for auditory brainstem response test). The median gestational age of the 3-T group was 30 weeks, 1 day, significantly higher (P<0.001) than the 1.5-T group (median gestational age: 20 weeks, 2 days). CONCLUSION: Our findings suggest that the increase in noise associated with 3 T does not increase the rate of clinically detectable hearing abnormalities.


Assuntos
Feto , Perda Auditiva Provocada por Ruído/congênito , Perda Auditiva Provocada por Ruído/diagnóstico , Imageamento por Ressonância Magnética/efeitos adversos , Triagem Neonatal/métodos , Acústica , Feminino , Testes Auditivos , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez
20.
Arch Gynecol Obstet ; 299(5): 1391-1398, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30719553

RESUMO

PURPOSE: The aim of this study is to analyze the correct staging of primary endometrial cancer (EC) using clinical examination and 3 Tesla (T) magnetic resonance imaging (MRI) results compared to histopathology. METHODS: In this prospective, non-randomized, single-center study, 26 women with biopsy-proven EC were evaluated. All women underwent clinical examination including transvaginal ultrasound (CE/US) and 3T MRI (T2-weighted, diffusion-weighted and dynamic contrast-enhanced sequences) prior to surgery. Spearman's correlation coefficient was employed to analyze the correlation between both staging methods and histopathology and generalized estimation equation analysis to compare their staging results. Main outcome measures are determinations of local tumor extent for EC on CE/US and 3T MRI compared to histopathology (gold standard). RESULTS: Sixteen women had an early-stage pT1a tumor, 10 a locally advanced ≥ pT1b tumor. The early stage was correctly diagnosed at CE/US in 100%, by MRI in 81%. Spearman's correlation coefficient was r = 1.0 (p < 0.001) for correlation of CE/US and histopathology, r = 0.93 (p < 0.001) for correlation of MRI and pathology. A locally advanced tumor stage was exactly diagnosed by MRI in 70% and at CE/US in 50%. CONCLUSIONS: CE/US is sufficient for staging T1a endometrial cancer, while MRI provides higher sensitivity in detecting locally advanced tumors. Based on our results, combining CE/US and 3T MRI in patients with at least suspected deep myometrial invasion offers a more reliable workflow for individual treatment planning.


Assuntos
Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/diagnóstico , Imageamento por Ressonância Magnética/métodos , Idoso , Neoplasias do Endométrio/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA