RESUMO
Video 1Demonstration of novel simulator of endoscopic hemostasis.
RESUMO
Purpose: Timely diagnosis of eye diseases is paramount to obtaining the best treatment outcomes. OCT and OCT angiography (OCTA) have several advantages that lend themselves to early detection of ocular pathology; furthermore, the techniques produce large, feature-rich data volumes. However, the full clinical potential of both OCT and OCTA is stymied when complex data acquired using the techniques must be manually processed. Here, we propose an automated diagnostic framework based on structural OCT and OCTA data volumes that could substantially support the clinical application of these technologies. Design: Cross sectional study. Participants: Five hundred twenty-six OCT and OCTA volumes were scanned from the eyes of 91 healthy participants, 161 patients with diabetic retinopathy (DR), 95 patients with age-related macular degeneration (AMD), and 108 patients with glaucoma. Methods: The diagnosis framework was constructed based on semisequential 3-dimensional (3D) convolutional neural networks. The trained framework classifies combined structural OCT and OCTA scans as normal, DR, AMD, or glaucoma. Fivefold cross-validation was performed, with 60% of the data reserved for training, 20% for validation, and 20% for testing. The training, validation, and test data sets were independent, with no shared patients. For scans diagnosed as DR, AMD, or glaucoma, 3D class activation maps were generated to highlight subregions that were considered important by the framework for automated diagnosis. Main Outcome Measures: The area under the curve (AUC) of the receiver operating characteristic curve and quadratic-weighted kappa were used to quantify the diagnostic performance of the framework. Results: For the diagnosis of DR, the framework achieved an AUC of 0.95 ± 0.01. For the diagnosis of AMD, the framework achieved an AUC of 0.98 ± 0.01. For the diagnosis of glaucoma, the framework achieved an AUC of 0.91 ± 0.02. Conclusions: Deep learning frameworks can provide reliable, sensitive, interpretable, and fully automated diagnosis of eye diseases. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.
RESUMO
Objectives: For more than a decade, 3-dimensional (3D) printing has been identified as an innovative tool for the surgical planning of double-outlet right ventricle (DORV). Nevertheless, lack of evidence concerning its benefits encourages us to identify valuable criteria for future prospective trials. Methods: We conducted a retrospective study involving 10 patients with DORV operated between 2015 and 2019 in our center. During a preoperative multidisciplinary heart team meeting, we harvested surgical decisions following a 3-increment step process: (1) multimodal imaging; (2) 3D virtual valvular reconstruction (3DVVR); and (3) 3D-printed heart model (3DPHM). The primary outcome was the proportion of predicted surgical strategy following each of the 3 steps, compared with the institutional retrospective surgical strategy. The secondary outcome was the change of surgical strategy through 3D modalities compared with multimodal imaging. The incremental benefit of the 3DVVR and 3DPHM over multimodal imaging was then assessed. Results: The operative strategy was predicted in 5 cases after multimodal imaging, in 9 cases after 3DVVR, and the 10 cases after 3DPHM. Compared with multimodal imaging, 3DVVR modified the strategy for 4 cases. One case was correctly predicted only after 3DPHM inspection. Conclusions: 3DVVR and 3DPHM improved multimodal imaging in the surgical planning of patients with DORV. 3DVVR allowed a better appreciation of the relationships between great vessels, valves, and ventricular septal defects. 3DPHM offers a realistic preoperative view at patient scale and enhances the evaluation of outflow tract obstruction. Our retrospective study demonstrates benefits of preoperative 3D modalities and supports future prospective trials to assess their impact on postoperative outcomes.
RESUMO
BACKGROUND: Micro-arteriovenous malformations (AVMs) can present challenges to neurosurgeons with respect to localization during resection. We sought to describe a novel method that merges super-selective 3-dimensional angiographic images with magnetic resonance imaging (MRI) sequences to facilitate frameless stereotaxic navigation during AVM surgery. METHODS: A retrospective analysis was performed comprising cases that employed merging of angiographic and MRI images for navigation purposes. Baseline clinical and imaging features were recorded. The technique and operative experiences were analyzed descriptively and presented alongside detailed illustrative cases. RESULTS: During the review period, 11 cases were identified where this technique was employed. Successful image acquisition and merging was possible in all cases. Complete obliteration of the target pathology was achieved in all cases. Precise localization of the micro-AVMs minimized dissection in eloquent cortex. CONCLUSIONS: Superselective 3-dimensional angiographic images merged to baseline MRI sequences facilitates planning and navigation during surgery for micro-AVMs.
RESUMO
In this clinical vignette, we describe a case of a patient with windsock-like posterior mitral annulus perforation at the site of annular calcification caused by infective endocarditis. Three-dimensional transesophageal images of the perforation resembling an "alien's mouth" are very striking for how 3-dimensional imaging can improve visualization of anatomy of the heart. (Level of Difficulty: Intermediate.).
RESUMO
A 24-year-old man presented with a nonischemic cardiomyopathy of unknown etiology, apical aneurysm, and a secondary mitral regurgitation. Computer tomography-derived 3-dimensional model of the patient's heart was an essential step in guiding the surgical management for an optimal outcome. (Level of Difficulty: Advanced.).
RESUMO
Ascending aorta pseudoaneurysm is a rare but potentially life-threatening complication of atherosclerosis, infections, chest trauma, transcatheter or surgical interventions. Due to high surgical risk, percutaneous closure is considered a valuable cost-effective therapeutic alternative. In this setting, 3D printing technology is emerging as a powerful tool to plan transcatheter repair. (Level of Difficulty: Advanced.).
RESUMO
A woman with recurrent presyncope caused by a functional atrioventricular (AV) block after meals, with limiting symptoms, underwent cardioneuroablation and AV node vagal denervation without pacemaker implantation. Normal AV conduction was recovered with complete abolishment of symptoms. (Level of Difficulty: Advanced.).
RESUMO
We present the case of a 17-year-old asymptomatic boy with a diagnosis of arrhythmogenic cardiomyopathy. Merging of cardiac magnetic resonance imaging and three-dimensional electroanatomic mapping provided striking visualization of the association between structural and electrical alterations and guided the decision to implant an implantable cardioverter defibrillator. (Level of Difficulty: Intermediate.).
RESUMO
Objectives: Localization of pulmonary nodules is challenging. However, traditional localization methods have high radiation doses and a high risk of complications. We developed a noninvasive 3-dimensional printing navigational template for intraoperative localization. It can reduce puncture-related complications and simplify the localization process. This study will verify the feasibility of this method. Methods: Patients with peripheral pulmonary nodules were included in this study. The computed tomography scan sequences were obtained to design a digital template model, which was then imported into a 3-dimensional printer to produce a physical navigational template. Finally, the navigational template is placed into the patient's pleural cavity for intraoperative localization. The precision of the nodule localization and associated complications were evaluated. Results: Twelve patients were finally included in this study. Intraoperative navigational template localization was used in all patients. The success rate of intraoperative nodule localization was 100%, and the median time of localization was 19.5 minutes (range, 16-23.5 minutes). The deviation median of the navigational template was 2.1 mm (range, 1.1-2.7 mm). Among the included patients, no significant complications occurred during intraoperative localization. Conclusions: The 3-dimensional printing template for intraoperative localization is feasible, will cause no trauma to the patient, and has acceptable accuracy for application in nodules localization. This navigational template greatly simplifies the localization process and may potentially break the dependence of percutaneous localization on computed tomography scanning.
RESUMO
Flexible bronchoscopy is becoming increasingly important for the removal of airway foreign bodies. However, in cases of risk of coughing during the procedure, rigid bronchoscopic intervention should be performed under general anesthesia. A 22-year-old man presented with history of several episodes of fever, for which he was administered antibiotics at a private clinic. In an annual chest X-ray and chest computed tomography examination, a foreign body, which appeared to be an orthodontic appliance, was discovered in the left main bronchus. It was deemed difficult to remove the foreign body using flexible bronchoscopy because of granulation tissue formation. Therefore, the patient was referred to our institution. We simulated the clinical situation using virtual reality, which indicated that the proximal and distal metallic parts of the appliance had grown into the bronchial mucosa. First, we inserted a rigid bronchoscope under general anesthesia and cut the granulation tissue using an insulation-tipped diathermic knife. Thereafter, we removed the appliance with grasping forceps under rigid bronchoscope guidance. In cases of risk of foreign body encroachment into the bronchial mucosa or granulation tissue development, rigid bronchoscopic intervention is effective. Furthermore, a VR-based intervention may be a useful option in such cases.
RESUMO
Objectives: To evaluate the safety and efficacy of a novel wireless localization technique that uses radiofrequency identification markers for small and deep lung lesions. Methods: Preliminary use of the device was retrospectively evaluated in 2 Japanese centers. Under general anesthesia, a marker was placed as close as possible to the tumor via computed tomography-guided bronchoscopy in a hybrid operation theater. Surgeons located the marker without lung palpation using a detection probe the tone of which changed to indicate the marker-probe distance. Efficacy was defined as functional marker placement (bronchoscopy time and marker position) and deep margin distance. Results: Twelve markers were placed for 11 lesions (mean size, 6.8 ± 2.7 mm) located at a mean depth from the pleura of 11.4 ± 8.4 mm (range = 0-26.0 mm). Of 12 markers, 7 markers (58.3%) were placed within 10 mm from the lesion in 25.5 ± 14.4 minutes. For the 11 wedge resections, markers were placed at a mean distance of 6.7 mm (range, 0-13.0 mm) from the lesion and a mean distance of 14.4 mm (range, 3.0-42.0 mm) from the pleura. All markers were recovered without complications, and all tumors were resected with negative margins. For 5 lesions >10 mm deep to the pleura (mean depth, 18.9 ± 5.5 mm; range, 11.0-26.0 mm), the median depth of the surgical margin was 11.6 ± 2.1 mm (range, 9.0-14.0 mm). Conclusions: Radiofrequency identification marking was safe and precisely localized small lung lesions, including their depth.
RESUMO
Intracardiac echocardiography (ICE) has historically had limited utility in complex structural interventions. Newer 3-dimensional ICE catheters have enhanced imaging and real-time functionality. We present a novel case of mitral valve transcatheter edge-to-edge repair where transesophageal imaging was limited by massive hiatal hernia and where complementary 3D ICE imaging enabled procedural success. (Level of Difficulty: Intermediate.).
RESUMO
We present a unique case of a paravalvular leak through a periannular channel around a bioprosthetic mitral valve. The role of multimodality imaging, in addition to novel technology, helped uncover the complex course of the jet, including its origin and direction, which translated into excellent procedural success. (Level of Difficulty: Advanced.).
RESUMO
Stents can be effectively implemented with no x-rays or contrast medium. Modified stents were successfully implanted in 9 of 11 attempted targets (82%) (7 carotid and 4 coronary arteries) using an impedance-sensitive navigation system and optical coherence tomography. Electroanatomical navigation systems can be used to assist interventionalists in performing arterial stenting while minimizing x-ray and contrast use, thereby potentially enhancing safety for both patients and catheterization laboratory staff members.
RESUMO
Left main coronary artery stenting requires rigorous planning and optimal execution. This case series presents a new approach to left main stenting guided by preprocedural patient-specific computational simulations. Three patients with significant left main artery disease underwent simulation-guided intervention using a novel stent scaffold purpose-built for large coronary arteries. (Level of Difficulty: Advanced.).
RESUMO
Translation of imaging into 3-dimensional (3D) printed patient-specific phantoms (3DPSPs) can help visualize complex cardiovascular anatomy and enable tailoring of therapy. The aim of this paper is to review the entire process of phantom production, including imaging, materials, 3D printing technologies, and the validation of 3DPSPs. A systematic review of published research was conducted using Embase and MEDLINE, including studies that investigated 3DPSPs in cardiovascular medicine. Among 2,534 screened papers, 212 fulfilled inclusion criteria and described 3DPSPs as a valuable adjunct for planning and guiding interventions (n = 108 [51%]), simulation of physiological or pathological conditions (n = 19 [9%]), teaching of health care professionals (n = 23 [11%]), patient education (n = 3 [1.4%]), outcome prediction (n = 6 [2.8%]), or other purposes (n = 53 [25%]). The most common imaging modalities to enable 3D printing were cardiac computed tomography (n = 131 [61.8%]) and cardiac magnetic resonance (n = 26 [12.3%]). The printing process was conducted mostly by material jetting (n = 54 [25.5%]) or stereolithography (n = 43 [20.3%]). The 10 largest studies that evaluated the geometric accuracy of 3DPSPs described a mean bias <±1 mm; however, the validation process was very heterogeneous among the studies. Three-dimensional printed patient-specific phantoms are highly accurate, used for teaching, and applied to guide cardiovascular therapy. Systematic comparison of imaging and printing modalities following a standardized validation process is warranted to allow conclusions on the optimal production process of 3DPSPs in the field of cardiovascular medicine.
RESUMO
Background & Aims: The low-phospholipid-associated cholelithiasis (LPAC) syndrome is a recently described peculiar form of cholelithiasis associated with the ATP-binding-cassette subfamily B, member 4 (ABCB4) gene deficiency. The purpose of our study was to analyse the relationship between magnetic resonance (MR) features and the genetic status of ABCB4 in people with LPAC syndrome. Methods: A total of 233 individuals with proven LPAC syndrome were enrolled between January 2003 and June 2018 in a retrospective single-centre study. Inclusion criteria included availability of clinical files, MR images, and genetic data. MR images were analysed by consensus among 3 senior radiologists blinded to the status of ABCB4 gene mutation. Results: A total of 125 individuals (mean age at first MR imaging 40.8 years; 66% females; 48% ABCB4 variant) were included. MR abnormalities were found in 61 (49%) of the 125 individuals. Forty (67%) of the 60 individuals with an ABCB4 gene variant had MR abnormalities as compared with 21 (33%) of the 65 individuals without an ABCB4 gene variant (odds ratio [OR] 4.1, 95% CI 1.9-9.5, p = 0.0001). Compared to individuals with no variant, individuals with an ABCB4 variant were more likely to show intrahepatic macrolithiasis (56 vs. 17%; OR 6.3, 95% CI 2.6-16.2, p <0.0001), bile duct dilatation (60 vs. 18%; OR 6.5, 95% CI 2.7-16.3, p <0.0001), and at least 1 MR feature of complication (35 vs. 15%; OR 2.9, 95% CI 1.1-7.8, p <0.05). Conclusions: ABCB4-related LPAC syndrome is associated with more frequent and severe hepatobiliary MR abnormalities. This finding strongly supports the major role of the ABCB4 gene in the pathogenesis of LPAC syndrome and highlights a genotype-phenotype association in this inherited disease with genetic heterogeneity. Lay summary: ABCB4-related LPAC syndrome associated with an ABCB4 gene variant demonstrates more frequent and severe hepatobiliary MR abnormalities. This finding supports the major role of the ABCB4 gene in the pathogenesis of LPAC syndrome.
RESUMO
Background & Aims: People with primary sclerosing cholangitis (PSC) have a variable and often progressive disease course that is associated with biliary and parenchymal changes. These changes are typically assessed by magnetic resonance imaging (MRI), including qualitative assessment of magnetic resonance cholangiopancreatography (MRCP). Our aim was to study the association of novel objective quantitative MRCP metrics with prognostic scores and patient outcomes. Methods: We performed a retrospective study including 77 individuals with large-duct PSC with baseline MRCP images, which were postprocessed to obtain quantitative measures of bile ducts using MRCP+™. The participants' ANALI scores, liver stiffness by vibration-controlled transient elastography, and biochemical indices were collected at baseline. Adverse outcome-free survival was measured as the absence of decompensated cirrhosis, liver transplantation (LT), or liver-related death over a 12-year period. The prognostic value of MRCP+-derived metrics was assessed by Cox regression modelling. Results: During a total of 386 patients-years, 16 cases of decompensation, 2 LTs, and 5 liver-related deaths were recorded. At baseline, around 50% of the patients were classified as being at risk of developing disease complications. MRCP+ metrics, particularly those describing the severity of bile duct dilatations, were correlated with all prognostic factors. Univariate analysis showed that MRCP+ metrics representing duct diameter, dilatations, and the percentage of ducts with strictures and/or dilatations were associated with survival. In a multivariable-adjusted analysis, the median duct diameter was significantly associated with survival (hazard ratio 10.9, 95% CI 1.3-90.3). Conclusions: MRCP+ metrics in people with PSC correlate with biochemical, elastographic, and radiological prognostic scores and are predictive of adverse outcome-free survival. Lay summary: In this study, we assessed in people with primary sclerosing cholangitis (PSC) the association of novel objective quantitative MRCP metrics automatically provided by a software tool (MRCP+) with prognostic scores and patient outcomes. We observed that MRCP+ metrics in people with PSC correlate with biochemical, elastographic, and radiological prognostic scores and are predictive of adverse outcome-free survival.
RESUMO
Objectives: Anomalous aortic origin of the right coronary artery (AAORCA) may cause ischemia and sudden death. However, the specific anatomic indications for surgery are unclear, so dobutamine-stress instantaneous wave-free ratio (iFR) is increasingly used. Meanwhile, advances in fluid-structure interaction (FSI) modeling can simulate the pulsatile hemodynamics and tissue deformation. We sought to evaluate the feasibility of simulating the resting and dobutamine-stress iFR in AAORCA using patient-specific FSI models and to visualize the mechanism of ischemia within the intramural geometry and associated lumen narrowing. Methods: We developed 6 patient-specific FSI models of AAORCA using SimVascular software. Three-dimensional geometries were segmented from coronary computed tomography angiography. Vascular outlets were coupled to lumped-parameter networks that included dynamic compression of the coronary microvasculature and were tuned to each patient's vitals and cardiac output. Results: All cases were interarterial, and 5 of 6 had an intramural course. Measured iFRs ranged from 0.95 to 0.98 at rest and 0.80 to 0.95 under dobutamine stress. After we tuned the distal coronary resistances to achieve a stress flow rate triple that at rest, the simulations adequately matched the measured iFRs (r = 0.85, root-mean-square error = 0.04). The intramural lumen remained narrowed with simulated stress and resulted in lower iFRs without needing external compression from the pulmonary root. Conclusions: Patient-specific FSI modeling of AAORCA is a promising, noninvasive method to assess the iFR reduction caused by intramural geometries and inform surgical intervention. However, the models' sensitivity to distal coronary resistance suggests that quantitative stress-perfusion imaging may augment virtual and invasive iFR studies.