1.
Eur Spine J ; 33(7): 2621-2629, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38733400

RESUMO

PURPOSE: To analyze the effect of endplate weakness prior to PLIF or TLIF cage implantation and compare it to the opposite intact endplate of the same vertebral body. In addition, the influence of bone quality on endplate resistance was investigated. METHODS: Twenty-two human lumbar vertebrae were tested in a ramp-to-failure test. One endplate of each vertebral body was tested intact and the other after weakening with a rasp (over an area of 200 mm2). Either a TLIF or PLIF cage was then placed and the compression load was applied across the cage until failure of the endplate. Failure was defined as the first local maximum of the force measurement. Bone quality was assessed by determining the Hounsfield units (HU) on CT images. RESULTS: With an intact endplate and a TLIF cage, the median force to failure was 1276.3N (693.1-1980.6N). Endplate weakening reduced axial endplate resistance to failure by 15% (0-23%). With an intact endplate and a PLIF cage, the median force to failure was 1057.2N (701.2-1735.5N). Endplate weakening reduced axial endplate resistance to failure by 36.6% (7-47.9%). Bone quality correlated linearly with the force at which endplate failure occurred. Intact and weakened endplates showed a strong positive correlation: intact-TLIF: r = 0.964, slope of the regression line (slope) = 11.8, p < 0.001; intact-PLIF: r = 0.909, slope = 11.2, p = 5.5E-05; weakened-TLIF: r = 0.973, slope = 12.5, p < 0.001; weakened-PLIF: r = 0.836, slope = 6, p = 0.003. CONCLUSION: Weakening of the endplate during cage bed preparation significantly reduces the resistance of the endplate to subsidence to failure: endplate load capacity is reduced by 15% with TLIF and 37% with PLIF. Bone quality correlates with the force at which endplate failure occurs.


Assuntos
Vértebras Lombares , Fusão Vertebral , Suporte de Carga , Humanos , Fusão Vertebral/métodos , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Pessoa de Meia-Idade , Masculino , Idoso , Feminino , Suporte de Carga/fisiologia , Fenômenos Biomecânicos/fisiologia , Adulto , Idoso de 80 Anos ou mais
2.
BMC Musculoskelet Disord ; 25(1): 533, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992608

RESUMO

BACKGROUND: The purpose of this study was to perform a biomechanical analysis to compare different medial column fixation patterns for valgus pilon fractures in a case-based model. METHODS: Based on the fracture mapping, 48 valgus pilon fracture models were produced and assigned into four groups with different medial column fixation patterns: no fixation (NF), K-wires (KW), intramedullary screws (IS), and locking compression plate (LCP). Each group contained wedge-in and wedge-out subgroups. After fixing each specimen on the machine, gradually increased axial compressive loads were applied with a load speed of one millimeter per minute. The maximum peak force was set at 1500 N. Load-displacement curves were generated and the axial stiffness was calculated. Five different loads of 200 N, 400 N, 600 N, 800 N, 1000 N were selected for analysis. The specimen failure was defined as resultant loading displacement over 3 mm. RESULTS: For the wedge-out models, Group-IS showed less displacement (p < 0.001), higher axial stiffness (p < 0.01), and higher load to failure (p < 0.001) than Group-NF. Group-KW showed comparable displacement under loads of 200 N, 400 N and 600 N with both Group-IS and Group-LCP. For the wedge-in models, no statistical differences in displacement, axial stiffness, or load to failure were observed among the four groups. Overall, wedge-out models exhibited less axial stiffness than wedge-in models (all p < 0.01). CONCLUSIONS: Functional reduction with stable fixation of the medial column is essential for the biomechanical stability of valgus pilon fractures and medial column fixation provides the enough biomechanical stability for this kind of fracture in the combination of anterolateral fixation. In detail, the K-wires can provide a provisional stability at an early stage. Intramedullary screws are strong enough to provide the medial column stability as a definitive fixation. In future, this technique can be recommended for medial column fixation as a complement for holistic stability in high-energy valgus pilon fractures.


Assuntos
Placas Ósseas , Fraturas da Tíbia , Humanos , Fenômenos Biomecânicos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/fisiopatologia , Fios Ortopédicos , Masculino , Suporte de Carga , Feminino , Adulto , Pessoa de Meia-Idade
3.
Artigo em Inglês | MEDLINE | ID: mdl-38809423

RESUMO

PURPOSE: Despite extensive literature available on the mechanical properties of knee ligaments and menisci, research on the mechanical properties of the meniscus-capsular junction (MCJ) is lacking. This study aims to investigate the biomechanical behavior of the MCJ of the medial meniscus using a tensile failure test. MATERIALS AND METHODS: Seven dissected cadaveric knees were used for biomechanical analysis. Tensile failure tests were performed using an INSTRON ElectroPuls E1000 stress system to measure stress/strain curves, maximum load at failure, elastic limit load, elongation at break, elongation at the elastic limit, and linear stiffness, were collected and analyzed. RESULTS: All ruptures occurred at the MCJ. The MCJ displayed similar mechanical properties to knee ligaments. Average values were: maximum load at failure (63.9 ± 3.2 N), yield load (52.9 N ± 2.6 N), elongation at break (2.5 mm ± 0.3 mm), elongation at the elastic limit (1.25 mm ± 0.15 mm), strain at break (47.0% ± 3.5%), strain at yield (23.2% ± 2.3%), and stiffness (56.6 ± 9. N/mm-1). CONCLUSION: The meniscus-capsular junction's mechanical properties are similar to other knee ligaments and may play a role in knee stability. The findings provide insights into the the behavior of the meniscus-capsular junction could have clinical implications for diagnosing and surgical treatment of meniscocapsular lesions.

4.
Biomed Eng Online ; 22(1): 13, 2023 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-36774524

RESUMO

The response of soft tissue to loading can be obtained by strain assessment. Typically, strain can be measured using electrical resistance with strain gauges (SG), or optical sensors based on the digital image correlation (DIC), among others. These sensor systems are already established in other areas of technology. However, sensors have a limited range of applications in medical technology due to various challenges in handling human soft materials. The aim of this study was to compare directly attached foil-type SG and 3D-DIC to determine the strain of axially loaded human ligament structures. Therefore, the medial (MCL) and lateral (LCL) collateral ligaments of 18 human knee joints underwent cyclic displacement-controlled loading at a rate of 20 mm/min in two test trials. In the first trial, strain was recorded with the 3D-DIC system and the reference strain of the testing machine. In the second trial, strain was additionally measured with a directly attached SG. The results of the strain measurement with the 3D-DIC system did not differ significantly from the reference strain in the first trial. The strains assessed in the second trial between reference and SG, as well as between reference and 3D-DIC showed significant differences. This suggests that using an optical system based on the DIC with a given unrestricted view is an effective method to measure the superficial strain of human ligaments. In contrast, directly attached SGs provide only qualitative comparable results. Therefore, their scope on human ligaments is limited to the evaluation of changes under different conditions.


Assuntos
Ligamentos Colaterais , Humanos , Fenômenos Biomecânicos , Ligamentos Colaterais/fisiologia , Articulação do Joelho/fisiologia , Imageamento Tridimensional , Estresse Mecânico
5.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 6080-6087, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37955675

RESUMO

PURPOSE: The aim of this study was to assess the biomechanical effects of subtalar ligament injury and reconstruction on stability of the subtalar joint in all three spatial planes. METHODS: Fifteen fresh frozen cadaveric legs were used, with transfixed tibiotalar joints to isolate motion to the subtalar joint. An arthrometer fixed to the lateral aspect of the calcaneus measured angular displacement in all three spatial planes on the inversion and eversion stress tests. Stress manoeuvres were tested with the intact joint, and then repeated after sequentially sectioning the inferior extensor retinaculum (IER), cervical ligament (CL), interosseous talocalcaneal ligament (ITCL), arthroscopic graft reconstruction of the ITCL, and sectioning of the calcaneo-fibular ligament (CFL). RESULTS: Sectioning the ITCL significantly increased angular displacement upon inversion and eversion in the coronal and sagittal planes. Reconstruction of the ITCL significantly improved angular stability against eversion in the axial and sagittal planes, and against inversion in the axial and coronal planes, at the zero time point after reconstruction. After sectioning the CFL, resistance to eversion decreased significantly in all three planes. CONCLUSION: Progressive injury of ligamentous stabilisers, particularly the ITCL, led to increasing angular displacement of the subtalar joint measured with the inversion and eversion stress tests, used in clinical practice. Reconstruction of the ITCL using tendon graft significantly stabilised the subtalar joint in the axial and sagittal planes against eversion and in the axial and coronal planes against inversion, immediately after surgery.


Assuntos
Instabilidade Articular , Articulação Talocalcânea , Humanos , Articulação Talocalcânea/cirurgia , Fenômenos Biomecânicos , Cadáver , Articulação do Tornozelo/cirurgia , Ligamentos Articulares/cirurgia , Ligamentos Articulares/lesões , Instabilidade Articular/cirurgia , Aloenxertos
6.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 4068-4075, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37318561

RESUMO

PURPOSE: To compare the biomechanical strength of different fixation configurations using a suspensory button in a soft-tissue quadriceps tendon graft for Anterior Cruciate Ligament (ACL) reconstruction. METHODS: Thirty fresh-frozen bovine Achilles tendons (10 mm wide, 50 mm long, and 4 mm thick) were used in this study. Tendons were assigned to three groups (n = 10 per group) with different suture configurations using adjustable loops with a suspensory button: group A, with the threads of an adjustable loop fixed by crossing at the tip of the loop and the entire loop; group B, continuous loops with hanging buttons were directly sutured to the tendon with eight simple sutures; group C, fixation was performed using the speed whip ripstop technique. Tensile tests with five cycles of preloading were performed at 50 N, held at 50 N for 1 min, and load-to-failure testing was conducted until rupture at 5 mm/min. The difference in the elongation and the maximum load-to-failure force were measured. RESULTS: The average elongation was significantly larger in group B (16.6 ± 2.2 mm) than in groups A (10.3 ± 2.4 mm) and C (10.0 ± 1.0 mm), (p < 0.001). The average load-to-failure force varied significantly between the three groups, 157.5 ± 33.4 N in group A, 253.4 ± 45.5 N in group B, and 337.7 ± 21.0 N in group C, (p < 0.001). CONCLUSION: Fixation using the speed whip ripstop technique to fix the suspensory button and soft-tissue transplant tendon resulted in minimal elongation and higher fixation strength. Simple devices that use this method have already been developed. Since it can be fixed using a relatively simple method, speed whip ripstop technique was shown to be advantageous for femoral fixation in ACL reconstruction using soft-tissue quadriceps tendon. The findings of this study could help surgeons reduce graft re-tear rates in ACL reconstruction using quadriceps tendons. LEVEL OF EVIDENCE: N/A, laboratory control study.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Humanos , Animais , Bovinos , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Tendões/transplante , Fêmur/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos
7.
J Shoulder Elbow Surg ; 32(3): 512-518, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36283564

RESUMO

BACKGROUND: The use of electrocautery to facilitate passage of a suture needle through bone without the aid of a drill or burr is a novel technique that has potential utility in orthopedic procedures, but there is a scarcity of research to support its utility. The specific aims of this cadaveric biomechanical study were to evaluate (1) the axial force reduction during suture passage using electrocautery when applied to rotator cuff repair, (2) the temperature change caused while using electrocautery, and (3) the failure loads and failure modes of this technique. METHODS: Five matched pairs of fresh frozen humeri were used, classified into 2 groups: with electrocautery on needle (study group) and without electrocautery on needle (control group). Four individual osseous tunnels were made on the greater tuberosity around the insertion of the supraspinatus tendon. Each specimen was sequentially tested in 2 parts: a needle penetration test (part I) to measure the peak axial force and temperature change and a single load-to-failure test (part II) to measure the maximum load to failure as well as the mechanism of failure. A No. 2 FiberWire suture with a straight needle was used. RESULTS: In part I, the mean peak axial force was lower in the study group compared with the control group for all osseous tunnels but was not statistically significant for individual tunnels. However, there was a significant decrease in peak axial force in the study group of 36% compared with the control group overall (P = .033). There was no significant change in temperature of the tunnel site with the use of electrocautery (mean: 0.2 ± 0.3°C, P = .435). In part II, 100% of the samples from each study group experienced bone tunnel failure. Forty percent of the trials in the study group found lower ultimate failure loads compared with the control group (reduction range: 7%-38%). There was no statistically significant difference in the ultimate failure load between either the loop tested or between the 2 study groups (loop 1: P = .352; loop 2: P = .270). CONCLUSION: Suture passage using electrocautery does significantly decrease the peak force needed to pass a needle directly through the greater tuberosity. This technique does not appear to burn the bone or weaken the bone tunnels. This technique may be useful during open rotator cuff repair or shoulder arthroplasty, although clinicians should be cautious when using this technique as its utility depends on bone quality and cortical thickness, and in vivo results may differ.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Fenômenos Biomecânicos , Cadáver , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Eletrocoagulação , Suturas , Técnicas de Sutura , Âncoras de Sutura
8.
J Orthop Sci ; 2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37393110

RESUMO

BACKGROUND: Fixing the posterolateral fragments of tibial plateau fractures has been challenging owing to potential neurovascular injuries and fibular head blocks. Several surgical approaches and fixation techniques have been reported, with distinct limitations. We propose a novel lateral tibia plateau hook plate system and compare its biomechanical stability with other fixation methods. METHODS: Twenty-four synthetic tibia models were simulated to present posterolateral tibial plateau fractures. These models were randomly assigned to three groups. Group A models were fixed with the lateral tibia plateau hook plate system, Group B with variable-angle anterolateral locking compression plates, and Group C with direct posterior buttress plates. The models' biomechanical stability was evaluated using static (gradually increased axial compressive loads) and fatigue (cyclically loaded from 100 to 600 N for 2000 cycles each) tests. RESULTS: Groups A and C models exhibited comparable axial stiffness, subsidence load, failure load, and displacement in the static test. Group A model exhibited higher subsidence and failure loads than Group B model. Groups A and C models exhibited comparable displacement at 100 N cyclic loading in the fatigue test. Group C model was more stable at higher loads. Group C model endured the highest subsidence cycle numbers, followed by Groups A and B models. CONCLUSIONS: The lateral tibia plateau hook plate system provided similar static biomechanical stability as the direct posterior buttress plates and comparable dynamic stability under limited axial loading. This system is a potential posterolateral treatment choice owing to its convenience and safety, in treating tibia plateau fractures.

9.
Arch Orthop Trauma Surg ; 143(6): 3163-3172, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35907003

RESUMO

INTRODUCTION: To date, there is no consensus on the optimal surgical strategy for the treatment of posterolateral tibial plateau fracture (PLF). This study introduced a novel, simple technique for treating PLF with a lateral locking plate plus antero-posterior lag screws (LPpLS). METHODS: We conducted a retrospective case series of 42 patients (Female/Male 19/23) with PLF treated with LPpLS between 1 July 2016 and 30 June 2019. Several pre- and postoperative outcomes were recorded, including operative time, intraoperative blood loss, CT findings, HSS, and ROM. For biomechanical studies, seventy synthetic tibiae with a simulated posterolateral split fracture were divided into seven groups. The biomechanical evaluation included displacement measurement at axial compression and fatigue testing. RESULTS: Forty-two eligible patients were followed up for an average of 18 months (range 14-21 months). Postoperative radiographs and CT showed good positioning of plates and screws, no fracture fragment loss, and normal articular surfaces in all 42 cases. The biomechanical study showed that the axial stiffness of LPpLS was in the same fashion as the posterior buttress plate and better than the other fixation methods (P < 0.05). Additionally, the LPpLS group had a smaller displacement of fracture fragments along the X-axis (medial to lateral direction) than the BP group (P < 0.01). CONCLUSIONS: The LPpLS technique could implement good reconstruction of the PLF, showing satisfactory therapeutic effect. The biomechanical evaluation demonstrated that the LPpLS had better stability in three-dimensional directions for PLF than other fixation strategies.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Masculino , Feminino , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Tíbia/cirurgia , Placas Ósseas , Fenômenos Biomecânicos
10.
Arch Orthop Trauma Surg ; 143(3): 1353-1359, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34905066

RESUMO

INTRODUCTION: Implant loosening is the most common indication for revision after total hip arthroplasty and is associated with progressive bone destruction. Contained defects can be treated with impaction bone grafting (IBG). Segmental defects are successfully restored with metal augmentation. Considering the increasing number of hip arthroplasty cases in young patients, it would appear sensible to reconstruct the bone stock for future revisions by biological bone defect reduction. The data on the treatment of segmental defects with IBG without additional stabilization are lacking. MATERIALS AND METHODS: Paprosky type IIB defects were milled into 15 porcine hemipelves with segmental defect angles of 40°, 80° and 120°. Contained defects without segmental defects (Paprosky type I) and acetabula without defects served as controls. After IBG, a cemented polyethylene cup (PE) was implanted in each case. Cup migration, rotational stiffness and maximum rupture torque were determined under physiological loading conditions after 2500 cycles. RESULTS: Compared with the control without defects, IBG cups showed an asymptotic migration of 0.26 mm ± 0.11 mm on average. This seating was not dependent on the size of the defect. The maximum rupture moment was also not dependent on the defect size for cups after IBG. In contrast, the torsional stiffness of cups with an 120° segmental defect angle was significantly lower than in the control group without defects. All other defects did not differ in torsional stiffness from the control without defects. CONCLUSIONS: IBG did not show inferior biomechanical properties in segmental type IIB defect angles up to 80°, compared to cups without defects.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Animais , Suínos , Acetábulo/cirurgia , Transplante Ósseo , Reoperação , Falha de Prótese , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos
11.
J Hand Ther ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37852910

RESUMO

BACKGROUND: This study focuses on the relationship between forearm muscles, carpal ligaments, and their impact on scapholunate joint stability across varying forearm rotations. This is crucial for optimizing pre and postoperative rehabilitation strategies for scapholunate joint dysfunction. PURPOSE: Our study aims to understand the kinetic influence of forearm muscles on scapholunate joint instability. We emphasize the significance of forearm rotation to enhance treatment efficacy. STUDY DESIGN: We conducted an experimental study to understand how forearm muscles contribute to the stability of the scapholunate joint during different degrees of forearm rotation and we focused on the joint effect of muscle groups rather than individual muscles for treatment protocols. RESULTS: Our findings shed light on the conservative treatment of dynamic scapholunate instability and the postoperative rehabilitation of scapholunate ligament repair. We found that the effect of forearm muscles significantly contributes to preserve stability in the scapholunate joint across various forearm rotational positions. These insights have practical implications for hand therapists, offering innovative strategies to enhance clinical practice. CONCLUSIONS: This research underscores the importance of considering forearm rotation when developing rehabilitation protocols for scapholunate joint instability and provides a valuable perspective in line with current rehabilitation principles.

12.
J Foot Ankle Surg ; 62(1): 61-67, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35477848

RESUMO

The jigless knotless internal brace surgery (JKIB), an alternative method for minimal invasive surgery (MIS) repair of acute Achilles tendon rupture, has advantages of preventing sural-nerve injury in MIS and superficial wound infection in open surgery, as previous clinical research demonstrates. However, no comparative study on the biomechanical performance between JKIB and other MIS techniques has been reported until now. In this study, 50 fresh porcine Achilles tendons were used to compare the JKIB with open surgery (two-stranded Krachow suture) with other MIS techniques, including Percutaneus Achilles Repair System (PARS), Speedbridge (SB), and Achillon Achilles Tendon Suture System (ACH), using a biomechanical testing with cyclic loading at 1 Hz. This test was used to simulate a progressive rehabilitation protocol where 20 to 100 N was applied in the first 250 cycles, followed by 20 to 190 N in the second 250 cycles, and then 20 to 369 N in the third 250 cycles. The cyclic displacement after 10, 100 and 250 cycles were recorded. The survived cycles were defined as a sudden drop in measured load. In survived cycles, the JKIB group (552.3 ± 72.8) had significantly higher cycles than the open, PARS, and ACH groups (204.3 ± 33.3, 395.9 ± 96.0, and 397.1 ± 80.9, respectively, p < .01) as analyzed by post hoc analysis, but no significant difference as compared with the SB group (641.6 ± 48.7). In cyclic displacement after 250 cyclic loadings, the JKIB group (11.29 ± 1.29) showed no significant difference as compared with PARS, SB, and ACH groups (12.21 ± 1.18, 9.80 ± 0.80, and 11.57 ± 1.10 mm, respectively) and significant less displacement than the open group (14.50 ± 1.85, p < .01). These findings suggest that JKIB could be an option for acute Achilles tendon repair in the MIS fashion due to no larger cyclic elongation compared with other MIS techniques.


Assuntos
Tendão do Calcâneo , Procedimentos de Cirurgia Plástica , Traumatismos dos Tendões , Animais , Suínos , Tendão do Calcâneo/cirurgia , Tendão do Calcâneo/lesões , Técnicas de Sutura , Traumatismos dos Tendões/cirurgia , Ruptura/cirurgia , Fenômenos Biomecânicos
13.
J Foot Ankle Surg ; 62(1): 7-13, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35370055

RESUMO

Midfoot and subtalar arthrodesis surgeries are performed to correct foot deformities and relieve arthritic pain. These procedures often employ intramedullary (IM) devices. The aim of the present study was to evaluate the biomechanical performance of a sustained dynamic compression (SDC) IM device compared to mechanically static devices in withstanding the effects of simulated bone resorption. Mechanically static and SDC IM devices were implanted in simulated bone blocks (n = 5/device). Compressive loads were measured with a custom-made mechanism to simulate bone resorption. The construct bending stiffness was determined from a 4-point bend test. Resorption was simulated by cutting a 1 mm or 2 mm gap in the midpoint of each construct and repeating the loading (n = 6/device). Initial compressive loads after device insertion were greater in the SDC IM devices when compared to the static devices (p < .01). The SDC device was able to sustain compression from 2 mm to 5.5 mm of simulated resorption depending upon device length, while the static devices lost compression within 1 mm of simulated resorption regardless of implant length (p < .001). In the 4-point bend test, the SDC device maintained its bending stiffness during simulated resorption whereas the static device displayed a significant loss in bending stiffness after 1 mm of simulated resorption (p < .001). The SDC device exhibited a significantly higher bending stiffness than the static device (p < .001). The SDC IM device demonstrated superior biomechanical performance during simulated resorption compared to static devices (p < .001). In conclusion, the ability of SDC IM devices to maintain construct stability and sustain compression across the fusion site while adapting to bone resorption may lead to greater fusion rates and overall quicker times to fusion than static IM devices. Surgeons who perform midfoot and subtalar arthrodesis procedures should be aware of a device's ability to sustain compression, especially in cases where bone resorption and joint settling are prevalent postoperatively.


Assuntos
Tornozelo , Reabsorção Óssea , Humanos , Artrodese/métodos , Articulação do Tornozelo/cirurgia , Reabsorção Óssea/cirurgia , Fenômenos Biomecânicos
14.
Eur Spine J ; 31(1): 28-36, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34773149

RESUMO

PURPOSE: Surgical treatment of thoracolumbar A3-fractures usually comprises posterior fixation-in neutral position or distraction-potentially followed by subsequent anterior support. We hypothesized that additional posterior compression in circumferential stabilization may increase stability by locking the facets, and better restore the sagittal profile. METHODS: Burst fractures Type A3 were created in six fresh frozen cadaver spine segments (T12-L2). Testing was performed in a custom-made spinal loading simulator. Loads were applied as pure bending moments of ± 3.75 Nm in all six movement axes. We checked range of motion, neutral zone and Cobb's angle over the injured/treated segment within the following conditions: Intact, fractured, instrumented in neutral alignment, instrumented in distraction, with cage left in posterior distraction, with cage with posterior compression. RESULTS: We found that both types of instrumentation with cage stabilized the segment compared to the fractured state in all motion planes. For flexion/extension and lateral bending, flexibility was decreased even compared to the intact state, however, not in axial rotation, being the most critical movement axis. Additional posterior compression in the presence of a cage significantly decreased flexibility in axial rotation, thus achieving stability comparable to the intact state even in this movement axis. In addition, posterior compression with cage significantly increased lordosis compared to the distracted state. CONCLUSION: Among different surgical modifications tested, circumferential fixation with final posterior compression as the last step resulted in superior stability and improved sagittal alignment. Thus, posterior compression as the last step is recommended in these pathologies.


Assuntos
Fraturas da Coluna Vertebral , Articulação Zigapofisária , Animais , Fenômenos Biomecânicos , Cadáver , Humanos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Fraturas da Coluna Vertebral/cirurgia
15.
BMC Musculoskelet Disord ; 23(1): 320, 2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35379221

RESUMO

BACKGROUND: Flexor tendon injuries pose many challenges for the treating surgeon, the principal of which is creating a strong enough repair to allow early active motion, preserving a low-profile of the repair to prevent buckling and subsequent pulley venting. A main concern is that a low-profile repair is prone to gap formation and repair failure. The Dynamic Tendon Grip (DTG™) all suture staple device claims to allow a strong and low-profile repair of the flexor tendon. The purpose of this study is to test the effects of the DTG™ device in early active motion simulation on range of motion, load to failure and gap formation and to compare it to traditional suturing technique. METHODS: Twelve fresh-frozen cadaveric fingers were assigned to two groups: DTG™ device (n = 9) and traditional suturing (double Kessler 4-core suture and a peripheral suture, n = 3). The deep flexor was incised and repaired in zone 2, and active motion simulation was carried out with a cyclic flexion-extension machine. Finger range of motion and gap formation were measured, as well as load to failure and method of repair failure. RESULTS: Following motion simulation, ROM decreased from 244.0 ± 9.9° to 234.5 ± 5.8° for the DTG™ device compared to 234.67 ± 6.51° to 211.67 ± 10.50° for traditional suturing. The DTG™ repair demonstrated gap formation of 0.93 ± 0.18 mm in 3 of 8 specimens after applying 1 kg load, which negated after load removal. Load to failure averaged 76.51 ± 23.15 N for DTG™ and 66.31 ± 40.22 N for the traditional repair. Repair failure occurred as the suture material broke for the DTG™ array and at the knot level for the traditional repair. CONCLUSIONS: The DTG™ all-suture stapling concept achieved a strong low-profile repair in zone 2 flexor tendon injury after active motion simulation. Further clinical studies will be needed to determine the effectiveness of this device compared to traditional techniques.


Assuntos
Traumatismos dos Tendões , Tendões , Fenômenos Biomecânicos , Estudos de Viabilidade , Força da Mão , Humanos , Suturas , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia
16.
BMC Musculoskelet Disord ; 23(1): 40, 2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996409

RESUMO

BACKGROUND: Intraoperative proximal femoral fractures (IPFF) are relevant complications during total hip arthroplasty. Fixation using cerclage wires (CW) represents a minimally-invasive technique to address these fractures through the same surgical approach. The goal of treatment is to mobilise the patient as early as possible, which requires high primary stability. This study aimed to compare different cerclage wire configurations fixing IPFF with regard to biomechanical primary stability. METHODS: Standardised IPFF (type II, Modified Mallory Classification) were created in human fresh frozen femora and were fixed either by two or three CW (1.6 mm, stainless steel). All cadaveric specimens (n = 42) were randomised to different groups (quasi-static, dynamic) or subgroups (2 CW, 3 CW) stratified by bone mineral density determined by Dual Energy X-ray Absorptiometry. Using a biomechanical testing setup, quasi-static and dynamic cyclic failure tests were carried out. Cyclic loading started from 200 N to 500 N at 1 Hz with increasing peak load by 250 N every 100 cycles until failure occurred or maximum load (5250 N) reached. The change of fracture gap size was optically captured. RESULTS: No significant differences in failure load after quasi-static (p = 0.701) or dynamic cyclic loading (p = 0.132) were found between the experimental groups. In the quasi-static load testing, all constructs resisted 250% of the body weight (BW) of their corresponding body donor. In the dynamic cyclic load testing, all but one construct (treated by 3 CW) resisted 250% BW. CONCLUSIONS: Based on this in vitro data, both two and three CW provided sufficient primary stability according to the predefined minimum failure load (250% BW) to resist. The authors recommend the treatment using two CW because it reduces the risk of vascular injury and shortens procedure time.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Fios Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Humanos
17.
BMC Musculoskelet Disord ; 23(1): 279, 2022 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-35321711

RESUMO

BACKGROUND: The acromioclavicular (AC) and coracoclavicular (CC) ligaments are important stabilizers of the AC joint. We hypothesized that AC and trapezoid ligament injuries induce AC joint instability and that the clavicle can override the acromion on cross-body adduction view even in the absence of conoid ligament injury. Accordingly, we investigated how sectioning the AC and CC ligaments contribute to AC joint instability in the cross-body adduction position. METHODS: Six fresh-frozen cadaveric shoulders were used in this study, comprising five male and one female specimen, with a mean age of 68.7 (range, 51-87) years. The left side of the trunk and upper limb, and the cervical and thoracic vertebrae and sternum were firmly fixed with an external fixator. The displacement of the distal end of the clavicle relative to the acromion was measured using an electromagnetic tracking device. We simulated AC joint dislocation by the sequential resection of the AC ligament, AC joint capsule, and CC ligaments in the following order of stages. Stage 0: Intact AC and CC ligaments and acromioclavicular joint capsule; stage 1: Completely sectioned AC ligament, capsule and joint disc; stage 2: Sectioned trapezoid ligament; and stage 3: Sectioned conoid ligament. The superior clavicle displacement related to the acromion was measured in the horizontal adduction position, and clavicle overriding on the acromion was assessed radiologically at each stage. Data were analyzed using a one-way analysis of variance and post-hoc tests. RESULTS: Superior displacement was 0.3 mm at stage 1, 6.5 mm at stage 2, and 10.7 mm at stage 3. On the cross-body adduction view, there was no distal clavicle overriding at stages 0 and 1, and distal clavicle overriding was observed in five cases (5/6: 83%) at stage 2 and in six cases (6/6: 100%) at stage 3. CONCLUSION: We found that AC and trapezoid ligament sectioning induced AC joint instability and that the clavicle could override the acromion on cross-body adduction view regardless of conoid ligament sectioning. The traumatic sections of the AC and trapezoid ligament may lead to high grade AC joint instability, and the distal clavicle may subsequently override the acromion.


Assuntos
Articulação Acromioclavicular , Instabilidade Articular , Articulação Acromioclavicular/lesões , Idoso , Cadáver , Clavícula/cirurgia , Feminino , Humanos , Ligamentos Articulares , Masculino
18.
Knee Surg Sports Traumatol Arthrosc ; 30(7): 2307-2313, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34807305

RESUMO

PURPOSE: To compare the biomechanical strength of different fixation configurations using suspensory buttons in a soft-tissue quadriceps tendon (QT) grafts in anterior cruciate ligament (ACL) reconstruction. METHODS: Forty bovine QTs, 6-cm long and 10-mm wide, were allocated into four groups with different suture configurations using suspensory buttons (n = 10 in each group): Group A, a baseball suture with a knot tied to the continuous loop with a suspensory button; Group B, same configuration as in Group A but with the knot tied at the opposite end of the baseball suture; Group C, a continuous loop with a suspensory button stitched directly to the QT with simple sutures, and Group D, a baseball suture tied directly to a suspensory button. Biomechanical testing was performed by preloading followed by cyclic loading for 500 cycles between 10 and 100 N. The length of elongation (mm) and maximum load to failure (N) were recorded, and compared among the four groups. RESULTS: Group C showed significantly smaller elongation (4.1 mm [95% CI 3.1-5.2]) than Group A (8.2 mm [95% CI 7.0-9.4]), Group B (10.5 mm [95% CI 7.7-13.3]), and Group D (8.5 mm [95% CI 7.0-9.9]) (A-C; P = 0.004, B-C; P = 0.0001, C-D; P = 0.0018). The maximum load to failure in Group C (386 N [95%CI 306-466]) was significantly higher than that in Group A (196 N [95% CI 141-251]), Group B (226 N [95% CI 164-289]), and Group D (212 N [95%CI 171-253]) (A-C; P = 0.0001, B-C; P = 0.0009, C-D; P = 0.0002). No significant differences were observed between Group A, B, and D in terms of elongation and maximum load to failure. CONCLUSION: The soft-tissue QT graft fixation configuration stitched directly to a continuous loop with suspensory button using simple sutures exhibits small elongation and high maximum load to failure among the four configurations. Regarding clinical relevance, direct suturing of the soft-tissue QT to a continuous loop with a suspensory button may be advantageous for femoral fixation in ACL reconstruction from a biomechanical perspective, and warrant future development of a novel fixation device using this principle.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Animais , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Bovinos , Humanos , Suturas , Tendões/transplante
19.
J Hand Surg Am ; 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35843762

RESUMO

PURPOSE: Distal radius fractures are common and often treated surgically with a volar plate. A complication of volar plating includes tendonitis or rupture of the flexor pollicis longus (FPL) tendon. We hypothesize that failure to restore the volar tilt of the distal radius results in increased pressure on the FPL tendon. METHODS: Ten fresh-frozen cadaveric wrists were assessed for this study. During testing, weights were suspended from the FPL tendon to stimulate muscle contraction. Reproducible fractures were created and fixed via volar plating. The contact force between FPL and the bone or plate edge was measured with a force transducer in 5 surgical conditions. These were assessed to evaluate whether failure to restore the volar tilt increases the pressure with a plate proximal or distal to the watershed line. RESULTS: Significant increases in contact forces were observed between the control and both conditions in which volar tilt was not restored, with mean increases of 1.9 N and 3.0 N. A significant increase in the contact force was found when placing the plate distal to the watershed line with a mean increase of 2.03 N comparing the failure to restore volar tilt and after restoring the volar tilt. Significant increases in contact force were also observed between the dorsal plate condition, which failed to restore the volar tilt, and both plate conditions with placement distal to the watershed line, with mean differences of 0.94 N and 1.09 N, respectively. CONCLUSIONS: Failure to restore the volar tilt in surgically treated distal radius fractures causes increased pressure on the FPL tendon. Plate placement distal to the watershed line also causes increased FPL tendon pressure over the plate edge. CLINICAL RELEVANCE: This study demonstrates the importance of restoring the volar tilt of the distal radius in surgically treated distal radius fractures and confirms that plate placement distal to the watershed line will increase pressure on the FPL tendon.

20.
Arch Orthop Trauma Surg ; 142(12): 3787-3796, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34748055

RESUMO

BACKGROUND: Recently, two novel concepts for intramedullary nailing of trochanteric fractures using a helical blade or interlocking dual screws have demonstrated advantages as compared to standard single-screw systems. However, these two concepts have not been subjected to a direct biomechanical comparison so far. The aims of this study were to investigate in a human cadaveric model with low bone quality (1) the biomechanical competence of nailing with the use of a helical blade versus interlocking screws, and (2) the effect of cement augmentation on the fixation strength of the helical blade. METHODS: Twelve osteoporotic and osteopenic human cadaveric femoral pairs were assigned for pairwise implantation using either a short TFN-ADVANCED Proximal Femoral Nailing System (TFNA) with a helical blade head element or a short TRIGEN INTERTAN Intertrochanteric Antegrade Nail (InterTAN) with interlocking screws. Six osteoporotic femora, implanted with TFNA, were augmented with bone cement. Four groups were created: group 1 (TFNA) paired with group 2 (InterTAN), both consisting of osteopenic specimens, and group 3 (TFNA augmented) paired with group 4 (InterTAN), both consisting of osteoporotic specimens. An unstable trochanteric AO/OTA 31-A2.2 fracture was simulated and all specimens were tested until failure under progressively increasing cyclic loading. RESULTS: Stiffness in group 3 was significantly higher versus group 4, p = 0.03. Varus (°) and femoral head rotation around the femoral neck axis (°) after 10,000 cycles were 1.9 ± 1.0/0.3 ± 0.2 in group 1, 2.2 ± 0.7/0.7 ± 0.4 in group 2, 1.5 ± 1.3/0.3 ± 0.2 in group 3 and 3.5 ± 2.8/0.9 ± 0.6 in group 4, being significantly different between groups 3 and 4, p = 0.04. Cycles to failure and failure load (N) at 5° varus or 10° femoral head rotation around the neck axis in groups 1-4 were 21,428 ± 6020/1571.4 ± 301.0, 20,611 ± 7453/1530.6 ± 372.7, 21,739 ± 4248/1587.0 ± 212.4 and 18,622 ± 6733/1431.1 ± 336.7, being significantly different between groups 3 and 4, p = 0.04. CONCLUSIONS: Nailing of trochanteric femoral fractures with use of helical blades is comparable to interlocking dual screws fixation in femoral head fragments with low bone quality. Bone cement augmentation of helical blades provides significantly greater fixation strength compared to interlocking screws constructs.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Parafusos Ósseos , Cimentos Ósseos , Unhas , Cadáver , Fraturas do Quadril/cirurgia , Pinos Ortopédicos , Fenômenos Biomecânicos