Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 164
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res Treat ; 203(3): 511-521, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37950089

RESUMO

PURPOSE: Axillary lymph nodes (LNs) with cortical thickness > 3 mm have a higher likelihood of malignancy. To examine the positive predictive value (PPV) of axillary LN cortical thickness in newly diagnosed breast cancer patients, and nodal, clinical, and tumor characteristics associated with axillary LN metastasis. METHODS: Retrospective review of axillary LN fine needle aspirations (FNAs) performed 1/1/2018-12/31/2019 included 135 axillary FNAs in 134 patients who underwent axillary surgery. Patient demographics, clinical characteristics, histopathology, and imaging features were obtained from medical records. Hypothesis testing was performed to identify predictors of axillary LN metastasis. RESULTS: Cytology was positive in 72/135 (53.3%), negative in 61/135 (45.2%), and non-diagnostic in 2/135 (1.5%). At surgery, histopathology was positive in 84 (62.2%) and negative in 51 (37.8%). LN cortices were thicker in metastatic compared to negative nodes (p < 0.0001). PPV of axillary LNs with cortical thickness ≥ 3 mm, ≥ 3.5 mm, ≥ 4 mm and, ≥ 4.25 mm was 0.62 [95% CI 0.53, 0.70], 0.63 [0.54, 0.72], 0.67 [0.57, 0.76] , and 0.74 [0.64, 0.83], respectively. At multivariable analysis, abnormal hilum (OR = 3.44, p = 0.016) and diffuse cortical thickening (OR = 2.86, p = 0.038) were associated with nodal metastasis. CONCLUSION: In newly diagnosed breast cancer patients, increasing axillary LN cortical thickness, abnormal fatty hilum, and diffuse cortical thickening are associated with nodal metastasis. PPV of axillary LN cortical thickness ≥ 3 mm and ≥ 3.5 mm is similar but increases for cortical thickness ≥ 4 mm. FNA of axillary LNs with cortex < 4 mm may be unnecessary for some patients undergoing sentinel LN biopsy.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Linfonodos/cirurgia , Linfonodos/patologia , Metástase Linfática/patologia , Axila/patologia , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela/métodos
2.
J Pak Med Assoc ; 74(1): 187-188, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38219200

RESUMO

Unsuspected thyroid cancer can be detected in multinodular goiter (MNG) where the risk of malignancy is 7-9%. Fine needle aspiration (FNAc) is performed in case of suspicious findings on ultrasound. With benign FNAC results there is no need for surgery unless the patient has pressure symptoms or cosmetic concerns, but the risk of overlooked malignancy is always present. We present the case of a patient with unexpected detection of papillary thyroid cancer on thyroid scan.


Assuntos
Bócio Nodular , Neoplasias da Glândula Tireoide , Humanos , Tireoidectomia , Bócio Nodular/diagnóstico por imagem , Bócio Nodular/cirurgia , Pertecnetato Tc 99m de Sódio , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico , Biópsia por Agulha Fina
3.
Eur Radiol ; 32(6): 4177-4185, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35079888

RESUMO

OBJECTIVES: Hemorrhage occasionally occurs after ultrasound (US)-guided biopsy of the thyroid and neck and sometimes leads to serious complications. We aimed to identify predictors of hemorrhagic complications after US-guided biopsy of the thyroid and neck. MATERIAL AND METHODS: In this retrospective study, we analyzed consecutive patients who underwent US-guided biopsy from April 2020 to November 2020. Procedure characteristics, US features, and peri- and post-procedural patient symptoms and signs were compared between patients with and without post-biopsy hemorrhage. Associations between clinical and imaging variables and post-biopsy hemorrhage were analyzed using univariate and multivariate regression analyses. RESULTS: A total of 305 patients who underwent US-guided biopsy of the thyroid and neck were included (219 women, 86 men; age range, 20-89 years). Seventeen (5.7%) cases of post-biopsy hemorrhage were detected 30 min after biopsy and manual compression. Among them, 10 developed hemorrhage at 30 min without immediate hemorrhage. In the multivariate analysis, a high tenderness score on the visual analog scale (VAS) at 30 min after biopsy (odds ratio [OR] 5.05, p < .001) was identified as an independent predictor of post-biopsy hemorrhage. In patients with hemorrhage at 30 min, tenderness scores significantly increased over 30 min of observation. CONCLUSIONS: High tenderness scores at 30 min after biopsy and manual compression were independent predictors of hemorrhage after US-guided biopsy of the thyroid and neck. The tenderness score could serve as a valuable marker to triage patients who require further observation and management after a US-guided biopsy of the thyroid and neck. KEY POINTS: • High tenderness scores at 30 min after compression were associated with the presence of delayed post-biopsy hemorrhage at 30 min. • Patients with hemorrhage at 30 min demonstrated a significant increase in tenderness scores over time. • High tenderness scores after biopsy site compression predicted the presence of delayed post-biopsy hemorrhage in the thyroid and neck.


Assuntos
Nódulo da Glândula Tireoide , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor no Peito , Feminino , Hemorragia/epidemiologia , Hemorragia/etiologia , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia de Intervenção/métodos , Adulto Jovem
4.
Eur Radiol ; 32(6): 3617-3630, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34973102

RESUMO

OBJECTIVES: To investigate the ability of the currently used ultrasound-based malignancy risk stratification systems for thyroid neoplasms (ATA, AACE/ACE/AME, K-TIRADS, EU-TIRADS, ACR-TIRADS and C-TIRADS) in distinguishing follicular thyroid carcinoma (FTC) from follicular thyroid adenoma (FTA). Additionally, we evaluated the ability of these systems in correctly determining the indication for biopsy. METHODS: Three hundred twenty-nine follicular neoplasms with definitive postoperative histopathology were included. The nodules were categorized according to each of six stratification systems, based on ultrasound findings. We dichotomized nodules into the positive predictive group of FTC (high and intermediate risk) and negative group of FTC based on the classification results. Missed biopsy was defined as neoplasms that were diagnosed as FTCs but for which biopsy was not indicated based on lesion classification. Unnecessary biopsy was defined as neoplasms that were diagnosed as FTAs but for whom biopsy was considered indicated based on classification. The diagnostic performance and missed and unnecessary biopsy rates were evaluated for each stratification system. RESULTS: The area under the curve of each system for distinguishing follicular neoplasms was < 0.700 (range, 0.511-0.611). The missed biopsy rates were 9.0-22.4%. The missed biopsy rates for lesions ≤ 4 cm and lesions sized 2-4 cm were 16.2-35.1% and 0-20.0%, respectively. Unnecessary biopsy rates were 65.3-93.1%. In ≤ 4 cm group, the unnecessary biopsy rates were 62.2-89.7%. CONCLUSION: The malignancy risk stratification systems can select appropriate nodules for biopsy in follicular neoplasms, while they have limitations in distinguishing follicular neoplasms and reducing unnecessary biopsy. Specific stratification systems and recommendations should be established for follicular neoplasms. KEY POINTS: • Current ultrasound-based malignancy risk stratification systems of thyroid nodules had low efficiency in the characterization of follicular neoplasms. • The adopted stratification systems showed acceptable performance for selecting FTC for biopsy but unsatisfactory performance for reducing unnecessary biopsy.


Assuntos
Adenocarcinoma Folicular , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Adenocarcinoma Folicular/diagnóstico por imagem , Adenocarcinoma Folicular/patologia , Biópsia por Agulha Fina , Humanos , Estudos Retrospectivos , Medição de Risco , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia
5.
Eur Radiol ; 31(5): 2903-2914, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33125564

RESUMO

OBJECTIVES: Ultrasound (US)-guided fine needle aspiration cytology (FNAC) and thyroglobulin measurement (FNA-Tg) are two common methods for confirming lymph node metastases (LNM) in patients with differentiated thyroid carcinoma (DTC). This study aimed at comparing the diagnostic performance of FNAC, FNA-Tg alone, and in combination by means of a meta-analysis. METHODS: Eligible articles were selected according to predefined criteria, and their quality was evaluated as per the QUADAS-2 checklist. We calculated pooled sensitivity (Se), specificity (Sp), positive/negative likelihood ratio, and diagnostic odds ratio (DOR), and plotted the summary receiver operating characteristic (SROC) curve using the Meta-DiSc1.4 software. RESULTS: Twenty-one studies pooling 1662 malignant and 1279 benign LNs from 2712 patients with DTC were included. The results showed that FNAC was more specific (pooled Sp, 0.98) while FNA-Tg was more sensitive (pooled Se, 0.94). FNAC and FNAC+FNA-Tg performed better postoperatively than FNA-Tg, while FNA-Tg performed better preoperatively. The combination of FNAC and FNA-Tg could achieve a better diagnostic performance than each alone (DOR 446.00, area under the curve [AUC] 0.9862), no matter preoperatively (DOR 378.14, AUC 0.9879) or postoperatively (DOR 788.72, AUC 0.9930). Besides, the combination of FNAC and FNA-Tg/serum-Tg ratio obtained a higher Sp (0.98) than the combination of FNAC and FNA-Tg. CONCLUSION: The addition of FNA-Tg, especially the FNA-Tg/serum-Tg ratio, to FNAC could increase the diagnostic performance of LNM in both preoperative and postoperative patients with DTC. Since one test or test combinations could perform differently according to the clinical situation, the best-fitting test should be chosen accordingly. KEY POINTS: • FNAC is more specific than FNA-Tg while FNA-Tg is more sensitive than FNAC. • The combination of FNAC and FNA-Tg could achieve a better diagnostic performance than either alone, no matter preoperatively or postoperatively. • The combination of FNAC and FNA-Tg/serum-Tg ratio could reach a higher Sp than the combination of FNAC and FNA-Tg.


Assuntos
Tireoglobulina , Neoplasias da Glândula Tireoide , Biópsia por Agulha Fina , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
6.
Eur Radiol ; 31(7): 5243-5250, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449191

RESUMO

OBJECTIVE: To investigate the diagnostic performances and unnecessary fine-needle aspiration (FNA) rates of two point-scale based TIRADS and compare them with a modified version using the ACR TIRADS' size thresholds. METHODS: Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. A total of 2106 thyroid nodules 10 mm or larger in size in 2084 patients with definitive cytopathologic findings were included. Ultrasonography categories were assigned according to each guideline. We applied the ACR TIRADS' size thresholds for FNA to the Kwak TIRADS and defined it as the modified Kwak TIRADS (mKwak TIRADS). Diagnostic performances and unnecessary FNA rates were evaluated for both the original and modified guidelines. RESULTS: Of the original guidelines, the ACR TIRADS had higher specificity, accuracy, and area under the receiver operating characteristic curve (AUC) (63.1%, 68.9%, and 0.748, respectively). When the size threshold of the ACR TIRADS was applied to the Kwak TIRADS, the resultant mKwak TIRADS had higher specificity, accuracy, and AUC (64.7%, 70.3%, and 0.765, respectively) than the ACR TIRADS. The mKwak TIRADS also had a lower unnecessary FNA rate than the ACR TIRADS (54.8% and 56.4%, respectively). The false-negative rate of the Kwak TIRADS was the lowest (1.9%) among all TIRADS. CONCLUSION: The modified Kwak TIRADS incorporating the size thresholds of the ACR TIRADS showed higher diagnostic performance and a lower unnecessary FNA rate than the original point-scale based TIRADS. KEY POINTS: • Of the original guidelines, the ACR TIRADS had the highest specificity, accuracy, and area under the receiver operating characteristic curve (AUC) (63.1%, 68.9%, and 0.748, respectively). • When the size threshold of the ACR TIRADS was applied to the Kwak TIRADS, the resultant modified version of Kwak TIRADS had higher specificity, accuracy, and AUC (64.7%, 70.3%, and 0.765, respectively) than the ACR TIRADS. • The false-negative rate of the Kwak TIRADS was the lowest (1.9%) among all TIRADS.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Biópsia por Agulha Fina , Humanos , Curva ROC , Estudos Retrospectivos , Ultrassonografia
7.
Eur Radiol ; 31(8): 5689-5698, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33599836

RESUMO

OBJECTIVE: Incidental diagnosis of thyroid nodules, and therefore of thyroid cancer, has definitely increased in recent years, but the mortality rate for thyroid malignancies remains very low. Within this landscape of overdiagnosis, several nodule ultrasound scores (NUS) have been proposed to reduce unnecessary diagnostic procedures. Our aim was to verify the suitability of five main NUS. METHODS: This single-center, retrospective, observational study analyzed a total number of 6474 valid cytologies. A full clinical and US description of the thyroid gland and nodules was performed. We retrospectively applied five available NUS: KTIRADS, ATA, AACE/ACE-AME, EUTIRADS, and ACRTIRADS. Thereafter, we calculated the sensitivity, specificity, PPV, and NPV, along with the number of possible fine-needle aspiration (FNA) sparing, according to each NUS algorithm and to clustering risk classes within three macro-groups (low, intermediate, and high risk). RESULTS: In a real-life setting of thyroid nodule management, available NUS scoring systems show good accuracy at ROC analysis (AUC up to 0.647) and higher NPV (up to 96%). The ability in FNA sparing ranges from 10 to 38% and reaches 44.2% of potential FNA economization in the low-risk macro-group. Considering our cohort, ACRTIRADS and AACE/ACE-AME scores provide the best compromise in terms of accuracy and spared cytology. CONCLUSIONS: Despite several limitations, available NUS do appear to assist physicians in clinical practice. In the context of a common disease, such as thyroid nodules, higher accuracy and NPV are desirable NUS features. Further improvements in NUS sensitivity and specificity are attainable future goals to optimize nodule management. KEY POINTS: • Thyroid nodule ultrasound scores do assist clinicians in real practice. • Ultrasound scores reduce unnecessary diagnostic procedures, containing indolent thyroid microcarcinoma overdiagnosis. • The variable malignancy risk of the "indeterminate" category negatively influences score's performance in real-life management of thyroid lesions.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Algoritmos , Biópsia por Agulha Fina , Humanos , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
8.
Radiol Med ; 126(1): 170-177, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32377914

RESUMO

OBJECTIVES: To evaluate the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after CT-guided lung biopsy (CT-LB). To test correlations of PTX and chest tube insertion (CTI) with PH and other imaging and procedural parameters. METHODS: Pre-procedural CT and CT-LB scans of 904 patients were examined. Incidence of PTX and PH and PH location (type-1 along needle track; type-2 perilesional) and severity according to its thickness (low grade < 6 mm; high grade > 6 mm) were recorded. PTX was considered clinically significant if treated with CTI, PH if treated with endoscopic/endovascular procedure. Binary logistic regression analyses were used to determine the effects of different imaging and procedural parameters on the likelihood to develop PTX, CTI and PH and to define their correlation. RESULTS: PTX occurred in 306/904 cases (33.8%); CTI was required in 18/306 (5.9%). PH occurred in 296/904 cases (32.7%), and no case required treatment. Nodule-to-pleura distance (ORPTX = 1.052; ORCTI = 1.046; ORPH 1.077), emphysema (ORPTX = 1.287; ORPH = 0.573), procedure time (ORPTX = 1.019; ORCTI = 1.039; ORPH = 1.019), target size (ORPTX = 0.982; ORPH = 0.968) and needle gauge (ORPTX = 0.487; ORCTI = 4.311; ORPH = 2.070) showed statistically significant correlation to PTX, CTI and PH. Type-1 PH showed a protective effect against PTX and CTI (ORPTX = 0.503; ORCTI = 0.416). CONCLUSION: PTX and PH have similar incidence after CT-guided lung biopsy. PH along needle track may represent a protective factor against development of PTX and against PTX requiring CTI.


Assuntos
Hemorragia/etiologia , Biópsia Guiada por Imagem/efeitos adversos , Pneumopatias/patologia , Lesão Pulmonar/etiologia , Pneumotórax/etiologia , Tomografia Computadorizada por Raios X , Idoso , Feminino , Hemorragia/epidemiologia , Humanos , Doença Iatrogênica , Incidência , Lesão Pulmonar/epidemiologia , Masculino , Pessoa de Meia-Idade , Pneumotórax/epidemiologia , Fatores de Risco
9.
J Pak Med Assoc ; 70(2): 308-312, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32063626

RESUMO

OBJECTIVE: To analyse the clinical and histopathological characteristics of parotid gland masses at a tertiary referral centre and to compare the results with those cited in literature. METHODS: The retrospective study was conducted at Adana Numune Training and Research Hospital, Adana, Turkey, and comprised data of patients undergoing parotid surgery between January 2011 and December 2016. They were evaluated in terms of age, gender, surgery method, fine-needle aspiration biopsy results, specimen reports and complications after the surgery for one year. SPSS 20 was used for data analysis. RESULTS: Of 170 parotidectomies, 97(57.1%) had been performed on males and 73(42.9%) on females. There were 145(85.3%) benign and 25(14.7%) malignant tumours. Pleomorphic adenoma 67(39.4%) and Warthin's tumour 56(32.9%) were the two most common benign tumours. Mucoepidermoid carcinoma 7(4.1%) and adenoid cystic carcinoma 6(3.5%) were the two most prevalent malignant tumours. Superficial parotidectomy 133(78.2%) was the main type of surgical intervention. The sensitivity of fine needle aspiration cytology for identifying malignant tumours was 64.71%, the specificity was 100% and overall accuracy of the procedure was 94.92%. CONCLUSIONS: Repeated aspirations for sampling different parts of the lesion should be performed on suspicion of malignancy, especially if fine needle aspiration cytology reported pleomorphic adenoma.


Assuntos
Adenolinfoma/patologia , Adenoma Pleomorfo/patologia , Carcinoma Adenoide Cístico/patologia , Carcinoma Mucoepidermoide/patologia , Neoplasias Parotídeas/patologia , Adenolinfoma/diagnóstico , Adenolinfoma/epidemiologia , Adenolinfoma/cirurgia , Adenoma Pleomorfo/diagnóstico , Adenoma Pleomorfo/epidemiologia , Adenoma Pleomorfo/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Carcinoma Adenoide Cístico/diagnóstico , Carcinoma Adenoide Cístico/epidemiologia , Carcinoma Adenoide Cístico/cirurgia , Carcinoma Mucoepidermoide/diagnóstico , Carcinoma Mucoepidermoide/epidemiologia , Carcinoma Mucoepidermoide/cirurgia , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Otorrinolaringológicos/métodos , Doenças Parotídeas/patologia , Neoplasias Parotídeas/diagnóstico , Neoplasias Parotídeas/epidemiologia , Neoplasias Parotídeas/cirurgia , Estudos Retrospectivos , Sialadenite/patologia , Centros de Atenção Terciária , Turquia/epidemiologia , Adulto Jovem
10.
Zhonghua Wai Ke Za Zhi ; 57(6): 404-407, 2019 Jun 01.
Artigo em Zh | MEDLINE | ID: mdl-31142062

RESUMO

With the advancement of clinical concepts and techniques in diagnosis and treatment of breast diseases, pathological evaluation of breast lesions and regional lymph nodes using tissue biopsy has been widely recognized in clinical practice. In order to standardize biopsy techniques of breast lesions and lymph nodes guided by ultrasound in application, Chinese Association of Breast Surgery organized domestic experts going into deep discussion, reiterating indications and contraindications in clinical operation and finally pointing out concrete suggestions on the operation guidelines.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Linfonodos/patologia , Axila/diagnóstico por imagem , Axila/patologia , Neoplasias da Mama/diagnóstico por imagem , Consenso , Feminino , Humanos , Biópsia Guiada por Imagem , Linfonodos/diagnóstico por imagem , Metástase Linfática , Guias de Prática Clínica como Assunto , Sensibilidade e Especificidade , Ultrassonografia
11.
Acta Clin Croat ; 58(2): 333-336, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31819330

RESUMO

The Bethesda System for Reporting Thyroid Cytopathology from 2009 introduced a new category in thyroid nodule fine-needle aspiration (FNA) findings named atypia of undetermined significance (AUS), which usually appears in around 5% of FNA findings. Our study aimed to assess the utility of AUS finding in determining the risk of malignancy in thyroid nodules. In our study, 160 patients with AUS finding on initial FNA were regularly followed-up. Total and specific malignancy rates were calculated after receiving histopathologic confirmation or histopathologic/cytologic exclusion of malignancy. Eventually 80 (50%) patients were referred to surgery, with malignancy rate of 37.5% on histopathology. Another 52 (32.5%) patients were confirmed to have benign nodules on repeat FNA. After combining results obtained from histopathologic reports with those obtained from cytologic follow-up, total malignancy rate was 22.72%. However, malignancy was confirmed in only one (5.26%) of 19 patients with AUS finding on repeat FNA with surgical and histopathologic follow-up. In conclusion, FNA is an extremely useful tool for clinicians to discriminate patients to be referred to surgery and those that can be followed-up safely without the need for further invasive procedures.


Assuntos
Biópsia por Agulha Fina , Nódulo da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/patologia , Transformação Celular Neoplásica , Feminino , Humanos , Masculino , Fatores de Risco , Centros de Atenção Terciária
12.
Eur Radiol ; 28(11): 4909-4918, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29789911

RESUMO

OBJECTIVES: To systematically review the published literature and evaluate the efficacy and safety of core needle biopsy (CNB) for initially detected thyroid nodules. METHODS: The Ovid-MEDLINE and Embase databases were searched for studies evaluating CNB for the diagnosis of initially detected thyroid nodules. A meta-analysis was performed to evaluate non-diagnostic results, inconclusive results and diagnostic accuracy for a diagnosis of malignancy with CNB. To overcome heterogeneity, multiple subgroup analyses were performed. The complication rate was also evaluated. RESULTS: Thirteen eligible studies, which included a total sample size of 9,166 patients with 13,585 nodules, were included. The pooled proportions were 3.5% (95% CI 2.4-5.1) for non-diagnostic results and 13.8% (95% CI 9.1-20.3) for inconclusive results. Considerable heterogeneity was observed among the studies in terms of the pooled proportions for CNB (I2=92.9%, 97%). With regard to the diagnostic performance for malignancy, the sensitivity was 80% (95% CI 75-85) and the specificity was 100% (95% CI 93-100). Only two major complications of CNB were observed. CONCLUSIONS: CNB demonstrates a low non-diagnostic result rate and high diagnostic accuracy for initially detected thyroid nodules and a low major complication rate. These findings indicate that CNB may be a feasible diagnostic tool for patients with initially detected thyroid nodules. KEY POINTS: CNB demonstrates high diagnostic accuracy for initially detected thyroid nodules. CNB demonstrates a low major complication rate. CNB may be a feasible diagnostic tool for patients with initially detected thyroid nodules.


Assuntos
Biópsia por Agulha Fina/métodos , Biópsia com Agulha de Grande Calibre/métodos , Biópsia Guiada por Imagem/métodos , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Humanos
13.
Zhonghua Yan Ke Za Zhi ; 54(9): 641-644, 2018 Sep 11.
Artigo em Zh | MEDLINE | ID: mdl-30220176

RESUMO

Intraocular biopsy is an important method of preoperative ophthalmic diagnosis. It can provide an objective basis for precise treatment of diseases, and has important guiding significance in the diagnosis of eye diseases, the selection of treatment strategies and the anticipation of prognosis. Eye biopsy technology has not yet been widely carried out to date in our country, and ophthalmologists should attach great importance to the role of intraocular biopsy in the diagnosis and treatment of eye diseases. Ophthalmologists should particularly improve the success rate of intraocular biopsy by strengthening the standardization of material sampling; facilitate the guiding effect of eye biopsy on the diagnosis, treatment and prognosis of eye diseases through efficient cooperation between clinician and pathologist; to improve the sensitivity and specificity of intraocular biopsy through organized combination of traditional cellular pathology with molecular pathology. (Chin J Ophthalmol, 2018, 54: 641-644).


Assuntos
Oftalmopatias , Biópsia , Olho , Oftalmopatias/diagnóstico , Humanos , Prognóstico , Vitrectomia
14.
Surg Endosc ; 31(12): 5143-5149, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28493167

RESUMO

BACKGROUND: As endoscopic ultrasound-guided tissue acquisition techniques evolve, there is increasing interest in obtaining optimal histological samples to improve diagnostic accuracy. In this study, we aimed to assess the tissue acquisition success rate and test performance characteristics of a novel endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) system. METHODS: We performed a retrospective review of consecutive patients undergoing EUS-guided tissue sampling of solid lesions using the SharkCore fine needle system in a tertiary referral facility. At least two passes were submitted for histology and diagnostic accuracy was evaluated. Comparison standard was based on final surgical pathology or minimum six-month clinical follow-up. RESULTS: Seventy-nine patients underwent 85 EUS-FNB procedures. Of the 85 histology specimens, 78 (91.7%) were adequate for diagnostic examination (includes six atypical/suspicious for adenocarcinoma). The sensitivity, specificity, and accuracy for diagnosis of malignancy with FNB were 87.1, 100, and 90.6%, respectively. Cytology was simultaneously sent in 43 cases with the same needle in addition to histology. Out of the 14 cases that were atypical/suspicious for adenocarcinoma or non-diagnostic on cytology, 11 cases (78.6%) achieved definite diagnoses on histology. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy combining histology and cytology were 90.3, 100, and 92.9%, respectively. No complications were reported after the procedures. CONCLUSION: In this initial experience with a new EUS-guided FNB system, obtaining small cores to submit for histological analysis was safe, technically feasible, and highly accurate. Most of the histological cores obtained via FNB yielded a definite diagnosis including in cases with equivocal cytomorphology. Further study is required to confirm these findings.


Assuntos
Adenocarcinoma/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias do Mediastino/patologia , Neoplasias Pancreáticas/patologia , Neoplasias Retroperitoneais/patologia , Adenocarcinoma/diagnóstico por imagem , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Neoplasias do Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Retroperitoneais/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
Pol J Radiol ; 81: 342-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27504146

RESUMO

BACKGROUND: Intranodal palisaded myofibroblastoma is a benign and very rare mesenchymal neoplasm of the lymph nodes originating from differentiated smooth muscle cells and myofibroblasts. CASE REPORT: We report a case of intranodal palisaded myofibroblastoma in an 84-year-old woman with Parkinson's disease that presented as a left inguinal mass. The diagnosis was made using ultrasound-guided fine needle aspiration biopsy and consequent cytopathological examination that included immunohistochemical analysis. Herein, we discuss the presentation of a rare intranodal palisaded myofibroblastoma with emphasis on its ultrasonographic and cytopathologic features. CONCLUSIONS: Intranodal palisaded myofibroblastoma should be considered in the differential diagnosis of inguinal lymphadenopathy and the diagnosis is possible with cytopathologic exam and immunohistochemical analysis using ultrasound-guided FNA biopsy, guiding the clinician to nodal excision rather than aggressive measures.

16.
Hong Kong Med J ; 21(1): 38-44, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25418928

RESUMO

OBJECTIVE: To evaluate the role of fine-needle aspiration cytology in the diagnosis of human immunodeficiency virus (HIV)-associated lymphadenopathy. DESIGN: Case series. SETTING: Tertiary care teaching hospital, India. PATIENTS: Fifty consecutive HIV-positive patients, who presented with lymphadenopathy at the out-patient department and antiretroviral therapy clinic. RESULTS: Tubercular lymphadenitis was the most common diagnosis, reported in 74% (n=37) of patients; 97.2% of them were acid-fast bacilli-positive. Reactive lymphadenitis and fungal lymphadenitis were present in 10 and 1 cases, respectively. The most common cytomorphological pattern of tubercular lymphadenitis was necrotising suppurative lymphadenitis, present in 43.2% (n=16) of patients. Of eight biopsies done in reactive cases, six turned out to be tubercular lymphadenitis. Fine-needle aspiration cytology had a sensitivity of 83.7% for diagnosing tubercular lymphadenitis. CONCLUSION: Necrotising suppurative lymphadenitis should be recognised as an established pattern of tubercular lymphadenitis. Reactive patterns should be considered inconclusive rather than a negative result, and re-evaluated with lymph node biopsy. Fine-needle aspiration cytology is an excellent test for diagnosing tubercular lymphadenitis in HIV-associated lymphadenopathy.


Assuntos
Complexo Relacionado com a AIDS/patologia , Linfonodos/patologia , Linfadenite/patologia , Adulto , Biópsia por Agulha Fina , Estudos Transversais , Feminino , HIV/patogenicidade , Humanos , Índia , Masculino , Pacientes Ambulatoriais
17.
Endocrinol Metab (Seoul) ; 38(1): 104-116, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36891657

RESUMO

BACKGRUOUND: There have concerns related with the potential harms of fine-needle aspiration biopsy (FNAB). We aimed to summarize the clinical complications and evaluate the safety of FNAB. METHODS: Studies related with the harms of FNAB were searched on MEDLINE, Embase, Cochrane library, and KoreaMed from 2012 to 2022. Also, studies reviewed in the previous systematic reviews were evaluated. Included clinical complications were postprocedural pain, bleeding events, neurological symptoms, tracheal puncture, infections, post-FNAB thyrotoxicosis, and needle tract implantation of thyroid cancers. RESULTS: Twenty-three cohort studies were included in this review. Nine studies which were related with FNAB-related pain showed that most of the subjects had no or mild discomfort. The 0% to 6.4% of the patients had hematoma or hemorrhage after FNAB, according to 15 studies. Vasovagal reaction, vocal cord palsy, and tracheal puncture have rarely described in the included studies. Needle tract implantation of thyroid malignancies was described in three studies reporting 0.02% to 0.19% of the incidence rate. CONCLUSION: FNAB is considered to be a safe diagnostic procedure with rare complications, which are mainly minor events. Thorough assessement of the patients' medical condition when deciding to perform FNABs would be advisable to lower potential complications.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/patologia , Biópsia por Agulha Fina/efeitos adversos , Biópsia por Agulha Fina/métodos , Neoplasias da Glândula Tireoide/patologia , Estudos de Coortes , Dor
18.
Eur J Radiol ; 164: 110857, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37172441

RESUMO

PURPOSE: To develop CT-based radiomics models for distinguishing between resectable PDAC and mass-forming pancreatitis (MFP) and to provide a non-invasive tool for cases of equivocal imaging findings with EUS-FNA needed. METHODS: A total of 201 patients with resectable PDAC and 54 patients with MFP were included. Development cohort: patients without preoperative EUS-FNA (175 PDAC cases, 38 MFP cases); validation cohort: patients with EUS-FNA (26 PDAC cases, 16 MFP cases). Two radiomic signatures (LASSOscore, PCAscore) were developed based on the LASSO model and principal component analysis. LASSOCli and PCACli prediction models were established by combining clinical features with CT radiomic features. ROC analysis and decision curve analysis (DCA) were performed to evaluate the utility of the model versus EUS-FNA in the validation cohort. RESULTS: In the validation cohort, the radiomic signatures (LASSOscore, PCAscore) were both effective in distinguishing between resectable PDAC and MFP (AUCLASSO = 0.743, 95% CI: 0.590-0.896; AUCPCA = 0.788, 95% CI: 0.639-0.938) and improved the diagnostic accuracy of the baseline onlyCli model (AUConlyCli = 0.760, 95% CI: 0.614-0.960) after combination with variables including age, CA19-9, and the double-duct sign (AUCPCACli = 0.880, 95% CI: 0.776-0.983; AUCLASSOCli = 0.825, 95% CI: 0.694-0.955). The PCACli model showed comparable performance to FNA (AUCFNA = 0.810, 95% CI: 0.685-0.935). In DCA, the net benefit of the PCACli model was superior to that of EUS-FNA, avoiding biopsies in 70 per 1000 patients at a risk threshold of 35%. CONCLUSIONS: The PCACli model showed comparable performance with EUS-FNA in discriminating resectable PDAC from MFP.


Assuntos
Neoplasias Pancreáticas , Pancreatite , Humanos , Estudos Retrospectivos , Neoplasias Pancreáticas/patologia , Pancreatite/diagnóstico por imagem , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Neoplasias Pancreáticas
19.
J Breast Cancer ; 26(2): 117-125, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37051648

RESUMO

PURPOSE: Fine-needle aspiration cytology (FNAC) of axillary lymph nodes (AxLNs) is performed to diagnose nodal metastasis in patients with breast cancer. Although the sensitivity of ultrasound-guided FNAC for identifying AxLN metastasis is in the range of 36%-99%, whether sentinel lymph node biopsy (SLNB) should be performed for neoadjuvant chemotherapy (NAC) patients with negative FNAC results is uncertain. This study aimed to determine the role of FNAC before NAC in the evaluation and management of AxLN in early breast cancer patients. METHODS: We retrospectively analyzed 3,810 clinically node-negative (a lymph node with no clinical metastasis without FNAC or radiological suspicion of metastasis with negative FNAC results) patients with breast cancer who underwent SLNB between 2008 and 2019. We compared the positivity rate of sentinel lymph nodes (SLNs) between patients who received and those who did not receive NAC with negative FNAC results or without FNAC and axillary recurrence rate in the neoadjuvant group with negative SLNB results. RESULTS: In the non-neoadjuvant (primary surgery) group, the positivity rate of SLNs in patients with negative FNAC results was higher than that in patients without FNAC (33.2% vs. 12.9%; p < 0.001). However, the SLN positivity rate of patients with negative FNAC results (false-negative rate for FNAC) in the neoadjuvant group was lower than that in the primary surgery group (3.0% vs. 33.2%; p < 0.001). After a median follow-up of 3 years, one axillary nodal recurrence was observed, which was a case from the neoadjuvant non-FNAC group. None of the patients in the neoadjuvant group with negative FNAC results had axillary recurrence. CONCLUSION: The false-negative rate for FNAC in the primary surgery group was high; however, SLNB was the proper axillary staging procedure for NAC patients who have clinically suspicious AxLN metastases on radiologic examination but negative FNAC results.

20.
Endosc Ultrasound ; 12(3): 319-325, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37693112

RESUMO

Background and Objectives: Several types of needles are available for EUS-guided tissue sampling of pancreatic lesions. Whereas fine-needle aspiration (FNA) needles typically provide cytological samples, fine-needle biopsy (FNB) needles are designed to obtain microcores with preserved tissue architecture. The aim of this study was to compare tissue amount and diagnostic yield between a modified Franseen-type FNB needle (TopGain; Medi-Globe GmbH, Grassau, Germany) and a standard FNA needle. Methods: We performed a prospective, multicenter randomized controlled study between June 2020 and September 2021, including patients with a solid pancreatic lesion referred for EUS-guided tissue sampling at 3 centers in Denmark. The patients were randomized 1:1 to either FNA needle or the novel FNB needle. Primary outcomes included the number of obtained tissue microcores and total and diagnostic tissue area. Results: Sixty-four patients were included. The median number of tissue microcores procured per pass was significantly higher in the FNB group compared with FNA (3 vs. 2, P < 0.001). Similarly, the mean total tissue area (2.74 vs. 0.44 mm2, P < 0.001) and mean diagnostic tissue area (1.74 vs. 0.28 mm2, P < 0.001) were more than 6-fold larger in the FNB samples compared with FNA. The median number of passes needed for a diagnostic sample was 1 for the FNB needle and 2 for FNA needle (P = 0.12). The novel FNB needle provided a higher percentage of samples of excellent quality (P = 0.002). Conclusions: The novel Franseen-type FNB needle seems to be significantly superior to a conventional FNA needle. The results of this study underline excellent performance of crown-cut needles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA