Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Gastroenterol Hepatol ; 39(6): 1008-1015, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38326979

RESUMO

BACKGROUND AND AIM: The study aims to evaluate the feasibility of body mass index (BMI)-based individualized small bowel preparation for computed tomography enterography (CTE). METHODS: In this prospective randomized controlled study, patients undergoing CTE were randomly assigned to the individualized group or standardized group. Those in individualized group were given different volumes of mannitol solution based on BMI (1000 mL for patients with BMI < 18.5 kg/m2, 1500 mL for patients with 18.5 kg/m2 ≤ BMI < 25 kg/m2 and 2000 mL for patients with BMI ≥ 25 kg/m2) while patients in the standardized group were all asked to consume 1500-mL mannitol solution. CTE images were reviewed by two experienced radiologists blindly. Each segment of the small bowel was assessed for small bowel image quality and disease detection rates. Patients were invited to record a diary regarding adverse events and acceptance. RESULTS: A total of 203 patients were enrolled and randomly divided into two groups. For patients with BMI < 18.5 kg/m2, 1000-mL mannitol solution permitted a significantly lower rate of flatulence (P = 0.045) and defecating frequency (P = 0.011) as well as higher acceptance score (P = 0.015), but did not affect bowel image quality and diseases detection compared with conventional dosage. For patients with BMI ≥ 25 kg/m2, 2000-mL mannitol solution provided better overall image quality (P = 0.033) but comparable rates of adverse events and patients' acceptance compared with conventional dosage. CONCLUSIONS: Individualized bowel preparation could achieve both satisfactory image quality and patients' acceptance thus might be an acceptable alternative in CTE.


Assuntos
Índice de Massa Corporal , Intestino Delgado , Manitol , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Manitol/administração & dosagem , Manitol/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Intestino Delgado/diagnóstico por imagem , Adulto , Idoso , Estudos de Viabilidade , Catárticos/administração & dosagem , Catárticos/efeitos adversos , Medicina de Precisão
2.
Gastroenterology ; 160(7): 2303-2316.e11, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33609503

RESUMO

BACKGROUND & AIMS: No reliable method for evaluating intestinal fibrosis in Crohn's disease (CD) exists; therefore, we developed a computed-tomography enterography (CTE)-based radiomic model (RM) for characterizing intestinal fibrosis in CD. METHODS: This retrospective multicenter study included 167 CD patients with 212 bowel lesions (training, 98 lesions; test, 114 lesions) who underwent preoperative CTE and bowel resection at 1 of the 3 tertiary referral centers from January 2014 through June 2020. Bowel fibrosis was histologically classified as none-mild or moderate-severe. In the training cohort, 1454 radiomic features were extracted from venous-phase CTE and a machine learning-based RM was developed based on the reproducible features using logistic regression. The RM was validated in an independent external test cohort recruited from 3 centers. The diagnostic performance of RM was compared with 2 radiologists' visual interpretation of CTE using receiver operating characteristic (ROC) curve analysis. RESULTS: In the training cohort, the area under the ROC curve (AUC) of RM for distinguishing moderate-severe from none-mild intestinal fibrosis was 0.888 (95% confidence interval [CI], 0.818-0.957). In the test cohort, the RM showed robust performance across 3 centers with an AUC of 0.816 (95% CI, 0.706-0.926), 0.724 (95% CI, 0.526-0.923), and 0.750 (95% CI, 0.560-0.940), respectively. Moreover, the RM was more accurate than visual interpretations by either radiologist (radiologist 1, AUC = 0.554; radiologist 2, AUC = 0.598; both, P < .001) in the test cohort. Decision curve analysis showed that the RM provided a better net benefit to predicting intestinal fibrosis than the radiologists. CONCLUSIONS: A CTE-based RM allows for accurate characterization of intestinal fibrosis in CD.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Intestinos/diagnóstico por imagem , Intestinos/patologia , Tomografia Computadorizada por Raios X/normas , Adulto , Doença de Crohn/complicações , Feminino , Fibrose , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 32(3): 1760-1769, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34510247

RESUMO

OBJECTIVES: To identify imaging features that can differentiate ectopic pancreas from true subepithelial tumors (SETs) in the small bowel using CT enterography and to assess whether radiologists' performance for the differentiation can be improved with the knowledge of significant CT findings. METHODS: CT images of ectopic pancreas (n = 29) and pathologically proven SETs (n = 61) were retrospectively reviewed by two radiologists in consensus. CT items analyzed included lesion location, contour (round, ovoid, flat/conformed), growth pattern, margin, homogeneity, necrosis, feeding vessel, surface ulceration, and enhancement pattern. For quantitative analysis, Hounsfield unit, longer diameter (LD), and shorter diameter (SD) of the lesion were measured. Univariate and multivariate analyses were performed. Diagnostic performance for differentiating ectopic pancreas from SETs was independently evaluated by two other radiologists using a receiver operating characteristic analysis. RESULTS: Age < 63 years, female sex, flat/conformed appearance, homogeneous enhancement, the absence of feeding vessels and necrosis, and an LD/SD ratio > 1.5 were significant variables for differentiating ectopic pancreas from small bowel SETs (p < 0.05). In the multivariate analysis, flat/conformed appearance, the absence of feeding vessels, and female sex remained suggestive features for ectopic pancreas. Area under the curve values for differentiating between two disease entities increased by both independent reviewers with knowledge of these significant CT features. CONCLUSIONS: Ectopic pancreas in the small bowel can be effectively differentiated from small (< 4.5 cm) true SETs by a flat/conformed appearance and the absence of feeding vessels on CT enterography. In addition, radiologists' performance for differentiating ectopic pancreas from small bowel SETs was improved with the knowledge of these significant CT findings. KEY POINTS: • Ectopic pancreas in the small bowel can be differentiated from small (< 4.5 cm) subepithelial tumors on CT. • Differential CT findings of the ectopic pancreas are a flat or conformed appearance and the absence of a feeding vessel. • Radiologists' performance for differentiating ectopic pancreas from small bowel SETs can be improved with the knowledge of differential CT findings.


Assuntos
Tumores do Estroma Gastrointestinal , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
4.
Radiol Med ; 127(10): 1068-1078, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35943658

RESUMO

BACKGROUND AND OBJECTIVE: Continuous assessment of disease activity remains a huge challenge during the follow-ups of patients with Crohn's disease (CD). In this paper, we aimed to evaluate the performance of contrast-enhanced ultrasound (CEUS) by comparing with computed tomography enterography (CTE) in the assessment of disease activity in CD. MATERIALS AND METHODS: Fifty-two patients diagnosed with CD were included in this study, using the CEUS and CTE as imaging methods for comparison. The selected parameters included the location and thickness of the thickest part of the intestinal wall, mesenteric fat proliferation, mesenteric vessels change, enhancement pattern and the presence of complications. Patients were clinically assessed using the Crohn's disease activity index (CDAI), C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Simple endoscopic score for Crohn's disease (SES-CD) was regarded as the reference standard. RESULTS: The location of the thickest part of the intestinal wall (κ = 0.653), bowel wall thickness (ICC = 0.795), mesenteric vessels change (κ = 0.692) and complications (κ = 0.796) displayed substantial agreement (0.61-0.80) between CEUS and CTE, while the detection of mesenteric fat proliferation (κ = 0.395) and enhancement pattern (κ = 0.288) showed fair consistency (0.21-0.40) for comparison. In CEUS, bowel wall thickness, mesenteric fat proliferation, enhancement pattern and mesenteric vessels change were statistically significant in assessing CD activity, while bowel wall thickness, mesenteric fat proliferation and mesenteric vessels change in CTE. Bowel wall thickness showed the best diagnostic performance in the assessment of CD activity at CEUS and CTE. CONCLUSION: CEUS provides a radiation-free and effective way to assess the CD activity in comparison with CTE, which also avoids frequent colonoscopy examinations, improves tolerance of patients, and reduces the cost of medical care, thereby serving as a useful tool for CD follow-up.


Assuntos
Doença de Crohn , Proteína C-Reativa , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Humanos , Intestinos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia
5.
J Gastroenterol Hepatol ; 34(9): 1511-1516, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30965387

RESUMO

BACKGROUND AND AIM: This study aimed to assess the clinical utility of computed tomography enterography (CTE) and identify factors associated with a diagnostic CTE for patients with obscure gastrointestinal bleeding (OGIB). METHODS: A retrospective observational study was performed at a Canadian tertiary care center from 2005 to 2015. A total of 138 patients underwent a CTE for OGIB. Univariate and multivariate logistic regressions were performed to determine factors associated with a diagnostic CTE. A highly sensitive clinical rule was then developed to help identify OGIB patients for whom a CTE may be beneficial in their clinical work-up. RESULTS: A possible bleeding source was identified in 30 (22%) cases. The presence of abdominal or constitutional symptoms as well as history of colorectal cancer was significantly associated with a positive CTE in univariate and multivariate analyses (P < 0.05). A positive CTE could be predicted based on the presence of abdominal or constitutional symptoms and history of colorectal cancer with 90% sensitivity (95% CI 74-98%) in our population. CONCLUSION: CTE identified a possible source of OGIB in one in five cases. In patients with the presence of abdominal or constitutional symptoms and a personal history of colorectal cancer, CTE may contribute to their diagnostic work-up.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/complicações , Hemorragia Gastrointestinal/diagnóstico por imagem , Intestinos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Idoso , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
6.
Pediatr Surg Int ; 35(11): 1197-1210, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31300851

RESUMO

PURPOSE: This exclusively surgical series on pediatric non-variceal gastrointestinal bleed (NVGIB) defines three levels of bleed site and describes etiology, bleed severity, diagnostic algorithm, and surgical management for each bleed site. Management challenges are detailed. METHODS: Patients aged ≤ 18 years treated surgically for NVGIB were analysed. RESULTS: Bleed site (n = 87) was classified as: upper gastrointestinal bleed (UGIB; n = 11); small bowel bleed (SBB: n = 52); and lower GIB (n = 24). Four etiology-based groups were identified: lesions with ectopic gastric mucosa (EGM; n = 33), tumours (n = 23), ulcers (n = 21), and vascular pathology (n = 8). Bleed severity spectrum was: acute severe bleed (n = 12); subacute overt bleed (n = 59); and occult GIB (n = 16). Preoperative diagnosis was obtained in all UGIB and LGIB lesions. Eighty-two percent of surgical SB lesions were diagnosed preoperatively on Tc99m pertechnetate scan, computed tomography enterography-angiography, and capsule endoscopy; remaining 18% were diagnosed at laparotomy with intra-operative enteroscopy (IOE). Surgical management was tailored to bleed site, severity, and etiology. Indications of IOE and approach to management challenges are detailed. CONCLUSIONS: The commonest site-specific bleed etiologies were duodenal ulcers for UGIB, EGM lesions for SBB, and tumours for LGIB. SBB presented diagnostic challenge. Diagnostic algorithm was tailored to bleed site, age-specific etiology, bleed severity, and associated abdominal/systemic symptoms. Management challenges were acute severe bleed, occult GIB, SBB, obscure GIB, and rare etiologies. IOE has a useful role in SBB management.


Assuntos
Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/cirurgia , Adolescente , Algoritmos , Falso Aneurisma/complicações , Endoscopia por Cápsula , Criança , Pré-Escolar , Coristoma/complicações , Doença de Crohn/complicações , Úlcera Duodenal/complicações , Feminino , Mucosa Gástrica , Hemorragia Gastrointestinal/diagnóstico por imagem , Neoplasias Gastrointestinais/complicações , Artéria Hepática , Humanos , Lactente , Masculino , Divertículo Ileal/complicações , Compostos Radiofarmacêuticos , Pertecnetato Tc 99m de Sódio , Tomografia Computadorizada por Raios X , Malformações Vasculares/complicações
7.
Med J Islam Repub Iran ; 33: 132, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32280638

RESUMO

Background: Crohn's disease (CD) is a chronic inflammatory disease of the gastrointestinal tract that is characterized by recurrent attacks and frequent recovery. The lifelong course of this disease requires frequent assessment of the disease activity. The aim of this study was to compare the effectiveness and safety of computed tomography enterography (CTE) to magnetic resonance enterography (MRE) in adults with CD. Methods: A systematic review of the literatures was performed to evaluate the effectiveness and safety of CTE in comparison with MRE. PubMed, Cochrane Library, Scopus, Web of Science, and Embase were searched. Effectiveness outcomes included were sensitivity, specificity, diagnosis difference, diagnostic odds ratio, and positive and negative likelihood. Quality assessment of the studies was conducted using the QADAS score. Meta-analysis was done by RevMan 5.3 for selected outcomes. Results: Five studies had eligibility for analyzing effectiveness. The meta-analysis results showed that diagnosis difference of MRE and CTE, for diagnosing active CD (0.03 CI 95% -0.07-0.13), fistula (-0.01 CI 95% -0.09-0.07), and cramping (-0.02 CI 95% -0.1- 0.06) were not statistically significant. Six studies were finally selected for safety assessment. The results showed that people who are examined with CTE frequently are at increased risk of developing cancer significantly, as they receive more than 50 msv of radiation per year. Conclusion: There was no significant difference between MRE and CTE in diagnosis of Crohn's activity, detection of bowel obstruction, and detection of fistula and stenosis of the alimentary canal. However, the assessment of the safety profile of MRE and CTE showed that MRE is meaningfully safer than CTE for evaluating the recurrence of CD.

8.
BMC Gastroenterol ; 18(1): 173, 2018 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-30413186

RESUMO

BACKGROUND: Evaluate the possibility of CT enterography (CTE) score system as a predictor in assessing active ulcerative colitis (UC) severity. METHODS: Forty-six patients with active UC with CTE and colonoscopy were enrolled. Based on modified Mayo score, patients were divided into three groups: mild (n = 10), moderate (n = 17) and severe (n = 19). A cumulative CTE score was calculated in each patient and its correlation with modified Mayo score was analyzed. The optimal cutoff values of CTE score were determined by receiver operating characteristic (ROC) curves analysis. RESULTS: Significant between-group differences were observed in CTE spectrums of mucosal bubbles, mural stratification, loss of haustration, enlarged mesenteric lymph nodes and engorged mesenteric vessels (P < 0.05). The cumulative CTE scores were significant difference between three groups (CTE score:4.9 ± 2.3, 7.6 ± 2.6, and 10.9 ± 2.0, respectively, P < 0.01). The cumulative CTE score showed a positive correlation with modified Mayo score (r = 0.835, P < 0.05). The optimal cut-off value for CTE score predicting moderate and severe UC was 9.5 (area under the curve [AUC]:0.847, sensitivity:78.9%, specificity:82.4%). CONCLUSION: Disease severity assessment by CTE score demonstrates strong positive correlation with severity established modified Mayo score. CTE score system maybe a potential predictor for active UC severity assessment.


Assuntos
Colite Ulcerativa/diagnóstico por imagem , Intestinos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Índice de Gravidade de Doença , Dor Abdominal/etiologia , Adulto , Idoso , Colite Ulcerativa/complicações , Colite Ulcerativa/patologia , Diarreia/etiologia , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Mucosa Intestinal/patologia , Intestinos/patologia , Linfonodos/patologia , Masculino , Mesentério/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
9.
Clin Gastroenterol Hepatol ; 15(1): 56-62, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27565523

RESUMO

BACKGROUND & AIMS: Previous studies have not found a correlation between fecal level of calprotectin and small bowel Crohn's disease (CD). However, these studies evaluated patients mainly by ileocolonoscopy, which views up to only the terminal ileum rather than entire small intestine. We investigated whether level of fecal calprotectin (FC) is a marker of active CD of the small bowel, identified by balloon-assisted enteroscopy and computed tomography enterography (CTE). METHODS: We performed a prospective study of 123 patients with CD (35 with ileitis, 72 with ileocolitis, and 16 with colitis) evaluated by balloon-assisted enteroscopy from May 2012 through July 2015 at Toho University Sakura Medical Centre in Japan. Patients with strictures detected by balloon-assisted enteroscopy were evaluated by CTE (n = 17). Fecal samples were collected from each patient, and levels of calprotectin were measured; patient demographic variables and medical history were also collected. We developed a CTE scoring system for disease severity that was based on bowel wall thickness, mural hyperenhancement, and engorged vasa recta. The association between level of FC and simple endoscopic index for CD score or CTE was evaluated by using Spearman rank correlation coefficient. RESULTS: Level of FC correlated with the simple endoscopic index for CD score (r = 0.6362, P < .0001), even in patients with only active disease of the small intestine (r = 0.6594, P = .0005). In the 17 patients with strictures that could not be passed with the enteroscope, CTE detected all lesions beyond the strictures as well as areas in the distal side of the strictures. Level of FC correlated with CTE score in these patients (r = 0.4018, P = .0011, n = 63). In receiver operating characteristic analyses, the FC cutoff value for mucosal healing was 215 µg/g; this cutoff value identified patients with healing with 82.8% sensitivity, 71.4% specificity, positive predictive value of 74.3%, negative predictive value of 80.6%, odds ratio of 12.0, and area under the receiver operating characteristic curve value of 0.81. CONCLUSIONS: A combination of measurement of level of FC and CTE appears to be effective for monitoring CD activity in patients with small intestinal CD, including patients with strictures that cannot be passed by conventional endoscopy.


Assuntos
Biomarcadores/análise , Doença de Crohn/patologia , Fezes/química , Intestino Delgado/patologia , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Enteroscopia de Balão , Doença de Crohn/diagnóstico por imagem , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Adulto Jovem
10.
Pediatr Radiol ; 47(10): 1321-1328, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28470387

RESUMO

BACKGROUND: Assessment for active Crohn disease by CT enterography and MR enterography relies on identifying mural and perienteric imaging features. OBJECTIVE: To evaluate the performance of established imaging features of active Crohn disease in children and adolescents on CT and MR enterography compared with histological reference. MATERIALS AND METHODS: We included patients ages 18 years and younger who underwent either CT or MR enterography from 2007 to 2014 and had endoscopic biopsy within 28 days of imaging. Two pediatric radiologists blinded to the histological results reviewed imaging studies and scored the bowel for the presence or absence of mural features (wall thickening >3 mm, mural hyperenhancement) and perienteric features (mesenteric hypervascularity, edema, fibrofatty proliferation and lymphadenopathy) of active disease. We performed univariate analysis and multivariate logistic regression to compare imaging features with histological reference. RESULTS: We evaluated 452 bowel segments (135 from CT enterography, 317 from MR enterography) from 84 patients. Mural imaging features had the highest association with active inflammation both for MR enterography (wall thickening had 80% accuracy, 69% sensitivity and 91% specificity; mural hyperenhancement had 78%, 53% and 96%, respectively) and CT enterography (wall thickening had 84% accuracy, 72% sensitivity and 91% specificity; mural hyperenhancement had 76%, 51% and 91%, respectively), with perienteric imaging features performing significantly worse on MR enterography relative to CT enterography (P < 0.001). CONCLUSION: Mural features are predictors of active inflammation for both CT and MR enterography, while perienteric features can be distinguished better on CT enterography compared with MR enterography. This likely reflects the increased conspicuity of the mesentery on CT enterography and suggests that mural features are the most reliable imaging features of active Crohn disease in children and adolescents.


Assuntos
Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Biópsia , Criança , Doença de Crohn/patologia , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
11.
Pediatr Radiol ; 46(13): 1873-1878, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27573371

RESUMO

Extensive heterotopic gastric mucosa of the small intestine is a rare, but potentially life-threatening condition characterized by multifocal or long-segment heterotopic gastric mucosa within the bowel lumen that is often associated with other anomalies including malrotation and annular pancreas. Although the imaging findings are characteristic, this entity may be unrecognized due to its unusual imaging appearance and rarity. CT or MR enterography and 99mTc-sodium pertechnetate scintigraphy can provide complementary information that enables specific diagnosis and accurate assessment of disease extent. We present a case of extensive heterotopic gastric mucosa of the small intestine imaged by simultaneous, combined 99mTc-sodium pertechnetate single photon-emission computed tomography (SPECT)/CT enterography to both familiarize the reader with the condition and describe an imaging strategy that enables specific diagnosis and assists with treatment planning.


Assuntos
Coristoma/diagnóstico por imagem , Enteropatias/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Imagem Multimodal , Endoscopia por Cápsula , Criança , Coristoma/cirurgia , Diagnóstico Diferencial , Feminino , Mucosa Gástrica , Humanos , Enteropatias/cirurgia , Intestino Delgado/cirurgia , Compostos Radiofarmacêuticos , Pertecnetato Tc 99m de Sódio , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
12.
J Pak Med Assoc ; 65(7): 710-4, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26160078

RESUMO

OBJECTIVE: To compare the efficacy of computed tomography enterography and magnetic resonance enterography in diagnosing small intestinal diseases. METHODS: The retrospective study comparing computed tomography enterography and magnetic resonance enterography for diagnosing diseases related to small intestine was conducted at Department of Radiology, Yantai Yuhuangding Hospital, Shandong, China, from July 2012 to February 2014. The efficacy of computed tomography enterography and magnetic resonance enterography results were evaluated for randomly-selected cases to compare the location and characteristics of small intestinal diseases together with small bowel endoscopy and clinical pathology observations. RESULTS: Of the 30 patients in the study, 19(63.3%) were males and 11 (36.7%) were females with an overall mean age of 33.6±19.2 years (range: 24-67 years). the clinical diagnostic accuracy of computed tomography enterography and magnetic resonance enterography was 24(80%) and 21(70%) cases respectively (p>0.05). CONCLUSIONS: Computed tomography enterography and magnetic resonance enterography are two techniques that complement each other for diagnostic purposes.


Assuntos
Doença de Crohn/diagnóstico , Tumores do Estroma Gastrointestinal/diagnóstico , Neoplasias Intestinais/diagnóstico , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Adulto , Idoso , Endoscopia Gastrointestinal , Feminino , Humanos , Enteropatias/diagnóstico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Scand J Gastroenterol ; 49(7): 807-13, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24730384

RESUMO

OBJECTIVE: Multidetector spiral computed tomography enterography (MSCTE) and ileocolonoscopy are used in evaluating inflammatory situation of Crohn's disease (CD) patients. The purpose of this study was to determine the disease severity of CD patients by combining the intestinal wall thickness by MSCTE with ileocolonoscopy. MATERIAL AND METHODS: This retrospective study included 50 patients with terminal ileal CD. Diagnosis was confirmed based on clinical features, endoscopy, and pathology. Patients underwent both MSCTE and ileocolonoscopy. Ileal wall thickness was measured and the disease severity was evaluated by CD activity index (CDAI). Intestinal mucosal lesions were scored by the simple endoscopic score for CD (SES-CD). RESULTS: Of the 50 patients with active terminal ileal CD, the comparison of scores between SES-CD and CDAI showed significant association with Spearman's rank correlation coefficient (p < 0.01). There were statistically significant correlation between the wall thickness and the SES-CD (p < 0.0001) as well as CDAI (p < 0.001), respectively, but no significant correlation between the wall thickness and the C-reactive protein (CRP) was found (p = 0.43). Moreover, we found that the wall thickness was preferential to predict the disease severity in the terminal ileal CD. CONCLUSION: MSCTE, in combination with ileocolonoscopy, is reliable to identify disease severity in CD patients and provides more accurate information in the diagnosis and treatment.


Assuntos
Doença de Crohn/diagnóstico por imagem , Íleo/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Índice de Gravidade de Doença , Adolescente , Adulto , Idoso , Colonoscopia , Doença de Crohn/patologia , Feminino , Humanos , Íleo/patologia , Mucosa Intestinal/diagnóstico por imagem , Mucosa Intestinal/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
14.
Dig Liver Dis ; 56(2): 248-257, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37758612

RESUMO

BACKGROUND: Residual abnormalities on computed tomography enterography (CTE) in Crohn's disease (CD) with endoscopic healing (EH) may have prognostic implications and affect therapeutic strategy. METHODS: CD patients with EH who underwent CTE between March 2015 and June 2022 were enrolled. CTE findings of the terminal ileum and the most severe segment of colon at the time of EH were assessed respectively for each patient. Cox regression analysis and Kaplan-Meier curves were used to evaluate the association between residual abnormalities and adverse outcomes. RESULTS: A total of 140 patients (217 digestive segments) were included. Mesenteric edema (hazard ratio [HR] = 3.61, 95% CI = 1.81-7.20, P<0.001), fibrofatty proliferation (HR = 3.40, 95% CI = 1.97-5.85, P<0.001) and active small bowel inflammation (HR = 2.74, 95% CI = 1.59-4.71, P<0.001) were risk factors for clinical relapse. Furthermore, we built a scoring system using the three parameters. Radiologic score ≥ 1 was the best threshold to predict clinical relapse (HR = 4.56, 95% CI = 2.54-8.19, P<0.001) and it was validated in different outcomes. CONCLUSION: The scoring system based on three residual abnormalities on CTE can predict adverse outcomes in CD patients with EH.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Íleo/diagnóstico por imagem , Endoscopia , Recidiva
15.
Insights Imaging ; 15(1): 69, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38472447

RESUMO

OBJECTIVES: Predicting secondary loss of response (SLR) to infliximab (IFX) is paramount for tailoring personalized management regimens. Concurrent pancreatic manifestations in patients with Crohn's disease (CD) may correlate with SLR to anti-tumor necrosis factor treatment. This work aimed to evaluate the potential of pancreatic radiomics to predict SLR to IFX in biologic-naive individuals with CD. METHODS: Three models were developed by logistic regression analyses to identify high-risk subgroup prone to SLR. The area under the curve (AUC), calibration curve, decision curve analysis (DCA), and integrated discrimination improvement (IDI) were applied for the verification of model performance. A quantitative nomogram was proposed based on the optimal prediction model, and its reliability was substantiated by 10-fold cross-validation. RESULTS: In total, 184 CD patients were enrolled in the period January 2016 to February 2022. The clinical model incorporated age of onset, disease duration, disease location, and disease behavior, whereas the radiomics model consisted of five texture features. These clinical parameters and the radiomics score calculated by selected texture features were applied to build the combined model. Compared to other two models, combined model achieved favorable, significantly improved discrimination power (AUCcombined vs clinical 0.851 vs 0.694, p = 0.02; AUCcombined vs radiomics 0.851 vs 0.740, p = 0.04) and superior clinical usefulness, which was further converted into reliable nomogram with an accuracy of 0.860 and AUC of 0.872. CONCLUSIONS: The first proposed pancreatic-related nomogram represents a credible, noninvasive predictive instrument to assist clinicians in accurately identifying SLR and non-SLR in CD patients. CRITICAL RELEVANCE STATEMENT: This study first built a visual nomogram incorporating pancreatic texture features and clinical factors, which could facilitate clinicians to make personalized treatment decisions and optimize cost-effectiveness ratio for patients with CD. KEY POINTS: • The first proposed pancreatic-related model predicts secondary loss of response for infliximab in Crohn's disease. • The model achieved satisfactory predictive accuracy, calibration ability, and clinical value. • The model-based nomogram has the potential to identify long-term failure in advance and tailor personalized management regimens.

16.
Eur J Radiol ; 178: 111607, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39033690

RESUMO

OBJECTIVE: To demonstrate the value of using 50 keV virtual monochromatic images with deep learning image reconstruction (DLIR) in low-dose dual-energy CT enterography (CTE). METHODS: In this prospective study, 114 participants (62 % M; 41.9 ± 16 years) underwent dual-energy CTE. The early-enteric phase was performed using standard-dose (noise index (NI): 8) and images were reconstructed at 70 keV and 50 keV with 40 % strength ASIR-V (ASIR-V40%). The late-enteric phase used low-dose (NI: 12) and images were reconstructed at 50 keV with ASIR-V40%, and DLIR at medium (DLIR-M) and high strength (DLIR-H). Image standard deviation (SD), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge-rise-slope (ERS) were computed. The quantitative comb sign score was calculated for the 27 patients with Crohn's disease. The subjective noise, image contrast, display of rectus artery were scored using a 5-point scale by two radiologists blindly. RESULTS: Effective dose was reduced by 50 % (P < 0.001) in the late-enteric phase to 3.26 mSv. The lower-dose 50 keV-DLIR-H images (SD:17.7 ± 0.5HU) had similar image noise (P = 0.97) as the standard-dose 70 keV-ASIR-V40% images (SD:17.7 ± 0.73HU), but with higher (P < 0.001) SNR, CNR, ERS and quantitative comb sign score (5.7 ± 0.17, 1.8 ± 0.12, 156.04 ± 5.21 and 5.05 ± 0.73, respectively). Furthermore, the lower-dose 50 keV-DLIR-H images obtained the highest score in the rectus artery visibility (4.27 ± 0.6). CONCLUSIONS: The 50 keV images in dual-energy CTE with DLIR provides high-quality images, with a 50 % reduction in radiation dose. Images with high contrast and density resolutions significantly enhance the diagnostic confidence of Crohn's disease and are essential for the clinical development of individualized treatment plans.


Assuntos
Aprendizado Profundo , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Adulto , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Pessoa de Meia-Idade , Razão Sinal-Ruído , Idoso , Doença de Crohn/diagnóstico por imagem
17.
Curr Med Imaging ; 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38310552

RESUMO

BACKGROUND: To compare the integrity, clarity, conciseness, etc., of the structured report (SR) versus free-text report (FTR) for computed tomography enterography of Crohn's disease (CD). METHODS: FTRs and SRs were generated for 30 patients with CD. The integrity, clarity, conciseness etc., of SRs versus FTRs, were compared. In this study, an evidence-based medicine practice model was utilized on 92 CD patients based on SR in order to evaluate its clinical value. Then, the life quality of the patients in two groups was evaluated before and after three months of intervention using an Inflammatory Bowel Disease Questionnaire (IBDQ). RESULTS: SRs received higher ratings for satisfaction with integrity (median rating 4.27 vs. 3.75, P=0.008), clarity (median rating 4.20 vs. 3.43, P=0.003), conciseness (median rating 4.23 vs. 3.20, P=0.003), the possibility of contacting a radiologist to interpret (median rating 4.17 vs. 3.20, P<0.001), and overall clinical impact (median rating 4.23 vs. 3.27, P<0.001) than FTRs. Besides, research group had higher score of IBDQ intestinal symptom dimension (median score 61.13 vs. 58.02, P=0.003), IBDQ systemic symptom dimension (median score 24.48 vs. 20.67, P<0.001), IBDQ emotional capacity dimension (median score 65.65 vs. 61.74, P<0.001), IBDQ social ability dimension (median score 26.80 vs. 22.37, P<0.001), and total IBDQ score (median score 178.07 vs. 162.80, P<0.001) than control group. CONCLUSION: The SR of CTE in CD patients was conducive to improving the quality and readability of the report, and CD patients' life quality could significantly improve after the intervention of an evidence-based medicine model based on SR.

18.
Insights Imaging ; 15(1): 28, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38289416

RESUMO

PURPOSE: To develop a CT-based radiomics model combining with VAT and bowel features to improve the predictive efficacy of IFX therapy on the basis of bowel model. METHODS: This retrospective study included 231 CD patients (training cohort, n = 112; internal validation cohort, n = 48; external validation cohort, n = 71) from two tertiary centers. Machine-learning VAT model and bowel model were developed separately to identify CD patients with primary nonresponse to IFX. A comprehensive model incorporating VAT and bowel radiomics features was further established to verify whether CT features extracted from VAT would improve the predictive efficacy of bowel model. Area under the curve (AUC) and decision curve analysis were used to compare the prediction performance. Clinical utility was assessed by integrated differentiation improvement (IDI). RESULTS: VAT model and bowel model exhibited comparable performance for identifying patients with primary nonresponse in both internal (AUC: VAT model vs bowel model, 0.737 (95% CI, 0.590-0.854) vs. 0.832 (95% CI, 0.750-0.896)) and external validation cohort [AUC: VAT model vs. bowel model, 0.714 (95% CI, 0.595-0.815) vs. 0.799 (95% CI, 0.687-0.885)), exhibiting a relatively good net benefit. The comprehensive model incorporating VAT into bowel model yielded a satisfactory predictive efficacy in both internal (AUC, 0.840 (95% CI, 0.706-0.930)) and external validation cohort (AUC, 0.833 (95% CI, 0.726-0.911)), significantly better than bowel alone (IDI = 4.2% and 3.7% in internal and external validation cohorts, both p < 0.05). CONCLUSION: VAT has an effect on IFX treatment response. It improves the performance for identification of CD patients at high risk of primary nonresponse to IFX therapy with selected features from RM. CRITICAL RELEVANCE STATEMENT: Our radiomics model (RM) for VAT-bowel analysis captured the pathophysiological changes occurring in VAT and whole bowel lesion, which could help to identify CD patients who would not response to infliximab at the beginning of therapy. KEY POINTS: • Radiomics signatures with VAT and bowel alone or in combination predicting infliximab efficacy. • VAT features contribute to the prediction of IFX treatment efficacy. • Comprehensive model improved the performance compared with the bowel model alone.

19.
Artigo em Inglês | MEDLINE | ID: mdl-39074035

RESUMO

BACKGROUND: Stricturing, penetrating complications and extraintestinal manifestations (EIMs) are frequent in patients with inflammatory bowel disease (IBD). There is limited data on the prevalence of these complications in patients with IBD. Therefore, we aimed to assess the burden of these complications detected incidentally on cross-sectional imaging. METHODS: A retrospective study conducted at two tertiary care centers in London, Ontario. Patients (≥18 years) with a confirmed diagnosis of IBD who underwent CT enterography (CTE) or MR enterography (MRE) between 1 Jan 2010 and 31 Dec 2018 were included. Categorical variables were reported as proportions and the mean and standard deviations were reported for continuous variables. RESULTS: A total of 615 imaging tests (MRE: 67.3% [414/615]) were performed in 557 IBD patients (CD: 91.4% [509/557], UC: 8.6% [48/557]). 38.2% (213/557) of patients were male, with mean age of 45.6 years (±15.8), and median disease duration of 11.0 years (±12.5). Among patients with CD, 33.2% (169/509) had strictures, with 7.8% having two or more strictures and 66.3% considered inflammatory. A fistula was reported in 10.6% (54/509), the most common being perianal fistula (27.8% [15/54]), followed by enterocutaneous fistula (16.8% [9/54]), and enteroenteric fistula (16.8% [9/54]). Additionally, 7.4% (41/557) of patients with IBD were found to have an EIM on cross-sectional imaging, with the most prevalent EIM being cholelithiasis (63.4% [26/41]), followed by sacroiliitis (24.4% [10/41]), primary sclerosing cholangitis (4.8% [2/41]) and nephrolithiasis (4.8% [2/41]). CONCLUSIONS: Approximately 40% of patients with CD undergoing cross-sectional imaging had evidence of a stricture or fistulizing disease, with 7% of patients with IBD having a detectable EIM. These results highlight the burden of disease and the need for specific therapies for these disease phenotypes.

20.
Abdom Radiol (NY) ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480547

RESUMO

OBJECTIVE: To demonstrate the clinical advantages of a deep-learning image reconstruction (DLIR) in low-dose dual-energy computed tomography enterography (DECTE) by comparing images with standard-dose adaptive iterative reconstruction-Veo (ASIR-V) images. METHODS: In this Institutional review board approved prospective study, 86 participants who underwent DECTE were enrolled. The early-enteric phase scan was performed using standard-dose (noise index: 8) and images were reconstructed at 5 mm and 1.25 mm slice thickness with ASIR-V at a level of 40% (ASIR-V40%). The late-enteric phase scan used low-dose (noise index: 12) and images were reconstructed at 1.25 mm slice thickness with ASIR-V40%, and DLIR at medium (DLIR-M) and high (DLIR-H). The 70 keV monochromatic images were used for image comparison and analysis. For objective assessment, image noise, artifact index, SNR and CNR were measured. For subjective assessment, subjective noise, image contrast, bowel wall sharpness, mesenteric vessel clarity, and small structure visibility were scored by two radiologists blindly. Radiation dose was compared between the early- and late-enteric phases. RESULTS: Radiation dose was reduced by 50% in the late-enteric phase [(6.31 ± 1.67) mSv] compared with the early-enteric phase [(3.01 ± 1.09) mSv]. For the 1.25 mm images, DLIR-M and DLIR-H significantly improved both objective and subjective image quality compared to those with ASIR-V40%. The low-dose 1.25 mm DLIR-H images had similar image noise, SNR, CNR values as the standard-dose 5 mm ASIR-V40% images, but significantly higher scores in image contrast [5(5-5), P < 0.05], bowel wall sharpness [5(5-5), P < 0.05], mesenteric vessel clarity [5(5-5), P < 0.05] and small structure visibility [5(5-5), P < 0.05]. CONCLUSIONS: DLIR significantly reduces image noise at the same slice thickness, but significantly improves spatial resolution and lesion conspicuity with thinner slice thickness in DECTE, compared to conventional ASIR-V40% 5 mm images, all while providing 50% radiation dose reduction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA