J Urol ; 211(4): 575-584, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38265365

RESUMO

PURPOSE: The widespread use of minimally invasive surgery generates vast amounts of potentially useful data in the form of surgical video. However, raw video footage is often unstructured and unlabeled, thereby limiting its use. We developed a novel computer-vision algorithm for automated identification and labeling of surgical steps during robotic-assisted radical prostatectomy (RARP). MATERIALS AND METHODS: Surgical videos from RARP were manually annotated by a team of image annotators under the supervision of 2 urologic oncologists. Full-length surgical videos were labeled to identify all steps of surgery. These manually annotated videos were then utilized to train a computer vision algorithm to perform automated video annotation of RARP surgical video. Accuracy of automated video annotation was determined by comparing to manual human annotations as the reference standard. RESULTS: A total of 474 full-length RARP videos (median 149 minutes; IQR 81 minutes) were manually annotated with surgical steps. Of these, 292 cases served as a training dataset for algorithm development, 69 cases were used for internal validation, and 113 were used as a separate testing cohort for evaluating algorithm accuracy. Concordance between artificial intelligence‒enabled automated video analysis and manual human video annotation was 92.8%. Algorithm accuracy was highest for the vesicourethral anastomosis step (97.3%) and lowest for the final inspection and extraction step (76.8%). CONCLUSIONS: We developed a fully automated artificial intelligence tool for annotation of RARP surgical video. Automated surgical video analysis has immediate practical applications in surgeon video review, surgical training and education, quality and safety benchmarking, medical billing and documentation, and operating room logistics.


Assuntos
Prostatectomia , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Inteligência Artificial , Escolaridade , Próstata/cirurgia , Prostatectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Gravação em Vídeo
2.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3912-3918, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36964782

RESUMO

PURPOSE: Robotic arm-assisted total knee arthroplasty (raTKA), currently a major trend in knee arthroplasty, aims to improve the accuracy of implant positioning and limb alignment. However, it is unclear whether and to what extent manual radiographic and navigation measurements with the MAKO™ system correlate. Nonetheless, a high agreement would be crucial to reliably achieve the desired limb alignment. METHODS: Thirty-six consecutive patients with osteoarthritis and a slight-to-moderate varus deformity undergoing raTKA were prospectively included in this study. Prior to surgery and at follow-up, a full leg radiograph (FLR) under weight-bearing conditions was performed. In addition, a computed tomography (CT) scan was conducted for preoperative planning. The hip-knee-ankle angle (HKA), mechanical lateral distal femur angle (mLDFA), mechanical medial proximal tibial angle (mMPTA) and joint line convergence angle (JLCA) were measured in the preoperative and follow-up FLR as well as in the CT scout (without weight-bearing) by three independent raters. Furthermore, the HKA was intraoperatively assessed with the MAKO™ system before and after raTKA. RESULTS: Significantly higher HKA values were identified for intraoperative deformity assessment using the MAKO system compared to the preoperative FLR and CT scouts (p = 0.006; p = 0.05). Intraoperative assessment of the HKA with final implants showed a mean residual varus deformity of 3.2° ± 1.9°, whereas a significantly lower residual varus deformity of 1.4° ± 1.9° was identified in the postoperative FLR (p < 0.001). The mMPTA was significantly higher in the preoperative FLR than in the CT scouts (p < 0.001). Intraoperatively, the mMPTA was adjusted to a mean of 87.5° ± 0.9° with final implants, while significantly higher values were measured in postoperative FLRs (p < 0.001). Concerning the mLDFA, no significant differences could be identified. CONCLUSION: The clinical importance of this study lies in the finding that there is a difference between residual varus deformity measured intraoperatively with the MAKO™ system and those measured in postoperative FLRs. This has implications for preoperative planning as well as intraoperative fine-tuning of the implant position during raTKA to avoid overcorrection of knees with slight-to-moderate varus osteoarthritis. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Perna (Membro) , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
3.
Clin Oral Investig ; 27(7): 3393-3403, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37256431

RESUMO

OBJECTIVE: This study aimed to evaluate the long-term stability of surgical maxillary expansion using patient-specific fixation implants (PSFIs) without intraoral retention. MATERIALS AND METHODS: Fifteen patients who had undergone segmented Le Fort I osteotomy and PSFIs with available preoperative (t0) early (t1) and 1-year follow-up computed tomography (CT) scans (t2) were evaluated. The early and 1-year 3D models were superimposed to transfer the bony landmarks; the distances between each pair of landmarks at the different time points were then measured. The distances between the canines and second molars were also measured directly on the CT scans. RESULTS: The achieved maxillary expansions ranged from a median of 4.39 (2.00-6.27) mm at the greater palatine foramina to a median of 2.14 (1.56-2 > 83) mm at the canine level of the palatal bone. One year postoperatively, the changes in skeletal diameters ranged from a median of - 0.53 (- 1.65 to 0.41) mm at the greater palatine foramina (p = 0.12) to 0.17 (- 0.09 to 0.32) mm at the canine level of the palatal bone (p = 0.56). Changes in dental arch diameters ranged from a median of - 0.6 (- 2 to 0.00) mm between the second molars to - 1.3 (- 1.8 to - 0.25) mm between the canines (P < 0.05). CONCLUSION: This study showed the stability of maxillary expansion osteotomy using PSFIs, even without postoperative intraoral retention. CLINICAL RELEVANCE: PSFIs are a reliable method for the surgical treatment of transverse maxillary discrepancy. PFSIs are easy-to-use and improve surgical accuracy.


Assuntos
Implantes Dentários , Técnica de Expansão Palatina , Humanos , Estudos Retrospectivos , Osteotomia de Le Fort/métodos , Maxila/cirurgia , Complicações Pós-Operatórias , Cefalometria/métodos
4.
Int Orthop ; 47(1): 83-87, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36102981

RESUMO

PURPOSE: The purpose is to verify the intra- and inter-operator reliability of an extramedullary (EM) accelerometer-based smart cutting guide for distal femoral resection during primary total knee arthroplasty (TKA). The hypothesis of the present study was that the use of the device would result in a good correlation between different operators with a difference between repeated measurements of less than 1°. METHODS: Twenty-five not consecutive patients with knee osteoarthritis undergone to primary TKA using an EM inertial-based cutting guide to perform distal femoral resection. In order to assess the agreement in femoral axis definition of the device, two operators performed three time each the manoeuvres necessary to define axis. Inter-rater agreement was evaluated with Bland and Altman agreement test. Intra-rater repeatability was evaluated analysing average results distribution of repeated measurements. Accuracy of the device was evaluated comparing differences between intra-operative device data with final implant alignment measured on post-operative longstanding x-rays using Students' t test. RESULTS: Agreement between the two operators was statistically significant (p < 0.05) with a bias of - 0.4° (95% CI - 0.6° to - 0.2°). Average difference between cut orientation measured with device and final implant position, measured on x-rays, was 0.2° (95% CI - 1.5° to 1.7°) with no statistical difference between the two measurements. Final implant alignment, measured on x-ray, was 90.2°, with 95% of cases distributed within range 88.0° to 92.0° for varus-valgus and 2.8° and with 95% of cases distributed within range 2.0° to 4.0° for flexion-extension. CONCLUSIONS: The EM accelerometer-based smart cutting guide used to perform distal femoral resection during primary TKA demonstrated a good intra- and inter-operator reliability in the present in vivo study.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Reprodutibilidade dos Testes , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia , Acelerometria , Articulação do Joelho/cirurgia
5.
BMC Oral Health ; 23(1): 150, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36918837

RESUMO

BACKGROUND: Zygomatic implants are widely used in the rehabilitation of severely atrophic maxillae, but implant placement is not without risks, and it can potentially cause damage to related anatomical structures. The aim of this study was to perform a comparative analysis of the accuracy of static navigation systems in placing zygomatic dental implants in comparison to dynamic navigation systems. METHODS: Sixty zygomatic dental implants were randomly allocated to one of three study groups, categorized by which implant placement strategy was used: A: computer-aided static navigation system (n = 20) (GI); B: computer-aided dynamic navigation system (n = 20) (NI); or C: free-hand technique (n = 20) (FHI). For the computer-aided study groups, a preoperative cone-beam computed tomography (CBCT) scan of the existing situation was performed in order to plan the approach to be used during surgery. Four zygomatic dental implants were inserted in each of fifteen polyurethane stereolithographic models (n = 15), with a postoperative CBCT scan taken after the intervention. The pre- and postoperative CBCT scans were then uploaded to a software program used in dental implantology to analyze the angular deviations, apical end point, and coronal entry point. Student's t-test was used to analyze the results. RESULTS: The results found statistically significant differences in apical end-point deviations between the FHI and NI (p = 0.0053) and FHI and GI (p = 0.0004) groups. There were also statistically significant differences between the angular deviations of the FHI and GI groups (p = 0.0043). CONCLUSIONS: The manual free-hand technique may enable more accurate placement of zygomatic dental implants than computer-assisted surgical techniques due to the different learning curves required for each zygomatic dental implant placement techniques.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea , Computadores , Software , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional
6.
J Evid Based Dent Pract ; 23(3): 101915, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37689457

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Yang S, Chen J, Li A, Deng K, Li P, Xu S. Accuracy of autonomous robotic surgery for single-tooth implant placement: a case series. J Dent. 2023;132:104451. doi:10.1016/j.jdent.2023.104451. Epub 2023 Feb 11. PMID: 36781099. SOURCE OF FUNDING: This case series study was supported by grants from the Guangdong Basic and Applied Basic Research Foundation, Science and Technology Projects in Guangzhou, Science Research Cultivation Program, and Clinical Research Initiation Plan of the Stomatological Hospital, Southern Medical University, China. TYPE OF STUDY/DESIGN: Case series. No a priori power calculation or pilot data. Nonconsecutive participant recruitment.


Assuntos
Implantes Dentários para Um Único Dente , Procedimentos Cirúrgicos Robóticos , Humanos , Estética Dentária , China , Tecnologia
7.
Clin Oral Investig ; 26(3): 2783-2791, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34782925

RESUMO

OBJECTIVE: A cohort prospective study was conducted to assess the three-dimensional positioning accuracy of the implant between pre-surgical and the final implant position using a static fully guided approach in the posterior area of the jaws. MATERIALS AND METHODS: A total of 60 implants (30 patients) were digitally analyzed after superimposing the Digital Imaging and Communications in Medicine (DICOM) files obtained from the Cone Beam Computed Tomography (CBCT) pre- and post-implant placement. The software calculations included deviations at the implant shoulder and at the implant apex, global deviation (3D offset), and angle deviation. Statistical analysis was performed with α = 0.05. RESULTS: Considering the total number of implants, mesiodistal, buccolingual, and apicocoronal mean deviations at the shoulder and implant apex were equal or below 0.21 ± 0.69 mm, and only the buccolingual mean deviation at the apex reached up to 0.67 ± 1.06 mm. The mesiodistal and apicocoronal deviations were not statistically significant at both the shoulder and apex levels of the implant. The mean total angular deviation was 5.62° ± 4.09. The main limitation of this surgical approach was the requirement for a wide mouth opening. CONCLUSIONS: Static fully guided surgery for dental implant placement exhibits minimum deviations respect to presurgical planning. The main limitation in the posterior areas is the requirement for a wide mouth opening. CLINICAL RELEVANCE: Even with minimum deviations clinically acceptable, precautions and safety margins must be respected when using static full-guided surgery to place dental implants.


Assuntos
Implantes Dentários , Arcada Edêntula , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Humanos , Imageamento Tridimensional , Arcada Edêntula/cirurgia , Estudos Prospectivos , Cirurgia Assistida por Computador/métodos
8.
Clin Oral Implants Res ; 32(5): 590-597, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33629419

RESUMO

OBJECTIVES: To compare the intra-osseous temperature reached during bone drilling for dental implant placement using open versus closed static surgical guides and evaluate the influence of bone density, osteotomy drilling depth, and irrigation fluid temperature. MATERIAL AND METHODS: 960 osteotomies were performed with 2 mm pilot drills in 16 solid rigid polyurethane foam blocks. Two main variables were considered: the guide type (open or closed guide) and bone density (hard (D1) or soft (D4). The blocks were divided into four groups according to the type of surgical template and bone density as follows: group one: closed guide and hard bone; group two: open guide and hard bone; group three: closed guide and soft bone; and group four: open guide and soft bone. A combination of different experimental conditions was used, including different bone osteotomy depths (6 or 13 mm) and irrigation fluid temperatures (5°C or 21°C). RESULTS: The highest mean temperature was found in group one (28.29 ± 4.02°C). In the soft bone groups (three and four), the mean maximum temperature decreased compared to groups one and two (dense bone) and was always higher with closed guides (23.38 ± 1.92°C) compared to open guides (21.97 ± 1.22°C) (p < .001). The osteotomy depth and irrigation fluid temperature also significantly influenced the bone temperature (p < .001), especially in hard bone. CONCLUSIONS: The greatest heat generation was observed in high-density bone. The final intra-bone temperature was about 1°C higher with a closed static surgical guide than with an open guide. The heat generation in osteotomy sites was substantially reduced by cooling the irrigation fluid to 5°C.


Assuntos
Implantes Dentários , Temperatura Alta , Implantação Dentária Endóssea , Osteotomia , Temperatura , Irrigação Terapêutica
9.
Sensors (Basel) ; 21(6)2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33802766

RESUMO

Minimally invasive surgery is widely used because of its tremendous benefits to the patient. However, there are some challenges that surgeons face in this type of surgery, the most important of which is the narrow field of view. Therefore, we propose an approach to expand the field of view for minimally invasive surgery to enhance surgeons' experience. It combines multiple views in real-time to produce a dynamic expanded view. The proposed approach extends the monocular Oriented features from an accelerated segment test and Rotated Binary robust independent elementary features-Simultaneous Localization And Mapping (ORB-SLAM) to work with a multi-camera setup. The ORB-SLAM's three parallel threads, namely tracking, mapping and loop closing, are performed for each camera and new threads are added to calculate the relative cameras' pose and to construct the expanded view. A new algorithm for estimating the optimal inter-camera correspondence matrix from a set of corresponding 3D map points is presented. This optimal transformation is then used to produce the final view. The proposed approach was evaluated using both human models and in vivo data. The evaluation results of the proposed correspondence matrix estimation algorithm prove its ability to reduce the error and to produce an accurate transformation. The results also show that when other approaches fail, the proposed approach can produce an expanded view. In this work, a real-time dynamic field-of-view expansion approach that can work in all situations regardless of images' overlap is proposed. It outperforms the previous approaches and can also work at 21 fps.


Assuntos
Algoritmos , Imageamento Tridimensional , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos
10.
J Biol Regul Homeost Agents ; 34(1 Suppl. 1): 161-164. DENTAL SUPPLEMENT, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32064851

RESUMO

INTRODUCTION: CBCT combined to intra-oral scansion are the means to build an endodontic surgical guide to perform an easier and safer access to the apex in endodontic micro-surgery. . METHODS: A 38-year-old woman presented chronic apical periodontitis, which involved the three roots of 16 that was treated by endodontic therapy several years ago elsewhere. The palatine channel was retreated, the mesio- and disto- buccal roots were instead treated with apicoectomy. A surgical template was printed by a 3D printer to obtain greater precision in the surgical access. CONCLUSIONS: Endodontic microsurgery has evolved over the years. New tools have been introduced to improve therapy, even if the basic principles have not changed. In fact, according to the literature, it is necessary to cut at least 3 mm of root to be sure of eliminating the anatomical variations and the accessory channels. Several Authors have devoted themselves to creating an endodontic surgical template, some in vitro and others in vivo. The present paper introduces a new method that allows a more conservative osteotomy and greater precision the surgical access. Further investigation are needed to test and improve the effectiveness of the treatment but this technique seems very promising because it is less invasive for the patient and simplifies the work for the dentist who can perform micro-surgery in an easier and faster way.


Assuntos
Apicectomia , Periodontite/cirurgia , Impressão Tridimensional , Cirurgia Assistida por Computador , Adulto , Endodontia/métodos , Feminino , Humanos , Microcirurgia , Raiz Dentária
11.
Sensors (Basel) ; 19(16)2019 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-31426577

RESUMO

Since the advantages of precise operation and effective reduction of radiation, robots have become one of the best choices for solving the defects of traditional fracture reduction surgery. This paper focuses on the application of robots in fracture reduction surgery, design of the mechanism, navigation technology, robotic control, interaction technology, and the bone-robot connection technology. Through literature review, the problems in current fracture reduction robot and its future development are discussed.


Assuntos
Fraturas Ósseas/cirurgia , Robótica , Fixação de Fratura , Humanos , Cirurgia Assistida por Computador/métodos
12.
Int Orthop ; 43(6): 1355-1363, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30196443

RESUMO

PURPOSE: Computer-assisted systems (CAS) for total knee arthroplasty (TKA) were expected to result in more accurate prosthesis implantation, better patient outcomes, and longer implant survival when compared to conventional instrumentation (CI). The aim of this study was to compare two groups of patients operated using CAS or CI at ten years follow-up. METHODS: One hundred twenty TKA patients, 60 using CAS and 60 using CI, were contacted after a decade for follow-up. Eligible patients received radiological examination to assess the lower-limb mechanical axis. They were also clinically assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Knee Society Score for Knee (KSS-K) and Function (KSS-F) Scoring. Kaplan-Meier survival analysis was performed to assess revisions, not for post-traumatic reasons. RESULTS: In CAS and CI groups, the lower-limb mechanical axis was 1.7° ± 2.4° and 1.5° ± 2.8°, respectively; corresponding KOOS values were 82.3 ± 14.3 and 78.6 ± 14.4; KSS-K values were 85.9 ± 11.1 and 85.0 ± 9.7; KSS-F values were 82.2 ± 19.3 and 83.8 ± 18. For these assessments, the differences between the two groups were not statistically significant (p > 0.05). Two CAS (3.8%) and three CI patients (5.7%) were revised. The Kaplan-Meier analysis showed no significant differences between the two groups. CONCLUSIONS: No significant differences were found at long-term follow-up in terms of radiographical-clinical outcomes and of implant survival between TKA operated using CAS or CI.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Articulação do Joelho/diagnóstico por imagem , Radiografia , Resultado do Tratamento
13.
Minim Invasive Ther Allied Technol ; 28(3): 165-171, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30113867

RESUMO

INTRODUCTION: In this study, we hypothesized a disposable low-cost needle clip with a specially designed electromagnetic (EM) tracking sensor. It could be mounted onto 16- to 22-gauge needles, allowing the tip of the needle to be tracked in CT or US image-guided procedures using the Aurora EM tracking system. MATERIAL AND METHODS: A 3 D printed EM needle clip case contains a pair of specially designed electromagnetic solenoids, positioned perpendicularly to each other in order to achieve six degrees of freedom for tracking the tip of the needle. The performance of the EM tracking needle clip was evaluated. RESULTS: A low-cost 3D-printed disposable needle clip with specially designed EM tracking sensors that can be mounted on 16- to 22-gauge needles was designed. This needle clip has a 570 mm ×600 mm ×600 mm (L × W × H) working volume, an error <0.7 mm in the axial direction and 0.8 mm in the radial direction. The targeting accuracy results are on par with the commercially available EM tracking needles. CONCLUSION: The designed EM needle clip provided successful needle tracking, with acceptable accuracy, and competitive performance compared to existing products. This proposed design may increase the clinical adoption of EM tracking needles because of its user-friendly design and low cost.


Assuntos
Fenômenos Eletromagnéticos , Agulhas , Instrumentos Cirúrgicos , Humanos , Imagens de Fantasmas
14.
Clin Oral Implants Res ; 29 Suppl 16: 436-442, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30328201

RESUMO

OBJECTIVES: Working Group 5 was assigned the task to review the current knowledge in the area of digital technologies. Focused questions on accuracy of linear measurements when using CBCT, digital vs. conventional implant planning, using digital vs. conventional impressions and assessing the accuracy of static computer-aided implant surgery (s-CAIS) and patient-related outcome measurements when using s-CAIS were addressed. MATERIALS AND METHODS: The literature was systematically searched, and in total, 232 articles were selected and critically reviewed following PRISMA guidelines. Four systematic reviews were produced in the four subject areas and amply discussed in the group. After emendation, they were presented to the plenary where after further modification, they were accepted. RESULTS: Static computer-aided surgery (s-CAIS), in terms of pain & discomfort, economics and intraoperative complications, is beneficial compared with conventional implant surgery. When using s-CAIS in partially edentulous cases, a higher level of accuracy can be achieved when compared to fully edentulous cases. When using an intraoral scanner in edentulous cases, the results are dependent on the protocol that has been followed. The accuracy of measurements on CBCT scans is software dependent. CONCLUSIONS: Because the precision intraoral scans and of measurements on CBCT scans and is not high enough to allow for the required accuracy, s-CAIS should be considered as an additional tool for comprehensive diagnosis, treatment planning, and surgical procedures. Flapless s-CAIS can lead to implant placement outside of the zone of keratinized mucosa and thus must be executed with utmost care.


Assuntos
Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Consenso , Bases de Dados Factuais , Implantação Dentária Endóssea , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Humanos , Boca Edêntula/cirurgia , Planejamento de Assistência ao Paciente , Medidas de Resultados Relatados pelo Paciente , Reprodutibilidade dos Testes , Software
15.
Emerg Radiol ; 25(5): 533-545, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29922866

RESUMO

This article reviews the conceptual framework, available evidence, and practical considerations pertaining to nascent and emerging advances in patient-centered CT-imaging and CT-guided surgery for maxillofacial trauma. These include cinematic rendering-a novel method for advanced 3D visualization, incorporation of quantitative CT imaging into the assessment of orbital fractures, low-dose CT imaging protocols made possible with contemporary scanners and reconstruction techniques, the rapidly growing use of cone-beam CT, virtual fracture reduction with design software for surgical pre-planning, the use of 3D printing for fabricating models and implants, and new avenues in CT-guided computer-aided surgery.


Assuntos
Traumatismos Maxilofaciais/diagnóstico por imagem , Traumatismos Maxilofaciais/cirurgia , Assistência Centrada no Paciente , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos
16.
Clin Oral Implants Res ; 28(5): 602-612, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27062555

RESUMO

AIM: To systematically assess the current dental literature comparing the accuracy of computer-aided implant surgery when using different supporting tissues (tooth, mucosa, or bone). MATERIAL AND METHODS: Two reviewers searched PubMed (1972 to January 2015) and the Cochrane Central Register of Controlled Trials (Central) (2002 to January 2015). For the assessment of accuracy, studies were included with the following outcome measures: (i) angle deviation, (ii) deviation at the entry point, and (iii) deviation at the apex. RESULTS: Eight clinical studies from the 1602 articles initially identified met the inclusion criteria for the qualitative analysis. Four studies (n = 599 implants) were evaluated using meta-analysis. The bone-supported guides showed a statistically significant greater deviation in angle (P < 0.001), entry point (P = 0.01), and the apex (P = 0.001) when compared to the tooth-supported guides. Conversely, when only retrospective studies were analyzed, not significant differences are revealed in the deviation of the entry point and apex. The mucosa-supported guides indicated a statistically significant greater reduction in angle deviation (P = 0.02), deviation at the entry point (P = 0.002), and deviation at the apex (P = 0.04) when compared to the bone-supported guides. Between the mucosa- and tooth-supported guides, there were no statistically significant differences for any of the outcome measures. CONCLUSIONS: It can be concluded that the tissue of the guide support influences the accuracy of computer-aided implant surgery.


Assuntos
Implantação Dentária Endóssea , Implantação Dentária , Cirurgia Assistida por Computador , Implantes Dentários , Humanos , Resultado do Tratamento
17.
Int Orthop ; 41(11): 2221-2227, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28921006

RESUMO

PURPOSE: An increasing number of orthopaedic surgeons are using computer aided planning tools for bone removal applications. The aim of the study was to consolidate a set of generic functions to be used for a 3D computer assisted planning or simulation. METHODS: A limited subset of 30 surgical procedures was analyzed and verified in 243 surgical procedures of a surgical atlas. Fourteen generic functions to be used in 3D computer assisted planning and simulations were extracted. RESULTS: Our results showed that the average procedure comprises 14 ± 10 (SD) steps with ten different generic planning steps and four generic bone removal steps. CONCLUSIONS: In conclusion, the study shows that with a limited number of 14 planning functions it is possible to perform 243 surgical procedures out of Campbell's Operative Orthopedics atlas. The results may be used as a basis for versatile generic intraoperative planning software.


Assuntos
Imageamento Tridimensional/métodos , Procedimentos Ortopédicos/métodos , Cirurgia Assistida por Computador/métodos , Osso e Ossos/cirurgia , Simulação por Computador , Humanos , Ortopedia/métodos , Planejamento de Assistência ao Paciente , Software
18.
Eur Spine J ; 25(6): 1738-44, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26210308

RESUMO

PURPOSE: We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. MATERIAL AND METHOD: We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. RESULTS: 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 × 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 × 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 × 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). CONCLUSION: The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).


Assuntos
Imageamento Tridimensional/métodos , Procedimentos Ortopédicos/métodos , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parafusos Pediculares , Estudos Prospectivos
19.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2461-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26438246

RESUMO

PURPOSE: Recently, the functional flexion axis has been considered to provide a proper rotational alignment of the femoral component in total knee arthroplasty. Several factors could influence the identification of the functional flexion axis. The purpose of this study was to analyse the estimation of the functional flexion axis by separately focusing on passive flexion and extension movements and specifically assessing its orientation compared to the transepicondylar axis, in both the axial plane and the frontal plane. METHODS: Anatomical and kinematic acquisitions were performed using a commercial navigation system on 79 patients undergoing total knee arthroplasty with cruciate substituting prosthesis design. The functional flexion axis was estimated from passive movements, between 0° and 120° of flexion and back. Intra-observer agreement and reliability, internal-external rotation and the angle with the surgical transepicondylar axis, in axial and frontal planes, were separately analysed for flexion and extension, in pre- and post-implant conditions. RESULTS: The analysis of reliability and agreement showed good results. The identification of the functional flexion axis showed statistically significant differences both in relation to flexion and extension and to pre- and post-implant conditions, both in frontal plane and in axial plane. The analysis of internal-external rotation confirmed these differences in kinematics (p < 0.05, between 25° and 35° of flexion). CONCLUSIONS: The identification of the functional flexion axis changed in relation to passive flexion and extension movements, above all in frontal plane, while it resulted more stable and reliable in axial plane. These findings supported the possible clinical application of the functional flexion axis in the surgical practice by implementing navigated procedures. However, further analyses are required to better understand the factors affecting the identification of the functional flexion axis. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Desenho de Prótese , Reprodutibilidade dos Testes , Rotação
20.
Cell Tissue Bank ; 17(4): 699-711, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27631324

RESUMO

Allograft reconstruction is an acceptable procedure for the recovery of normal anatomy after the bone tumor resection. During the past few years, several automated methods have been proposed to select the best anatomically matching allograft from the virtual donor bone bank. The surface-based automated method uses the contralateral healthy bone to obtain the normal surface shape of the diseased bone, which could achieve good matching of the defect and the selected allograft. However, the surface-based method focuses on the matching of the whole bone so that the matching of the contact surface between the allograft and the recipient bone may not be optimal. To deal with the above problem, we propose a cutting contour based method for the allograft selection. Cutting contour from the recipient bone could reflect the structural information of the defect and is seldom influenced by tumor. Thus the cutting contour can be used as the matching template to find the optimal alignment of the recipient bone and the allograft. The proposed method is validated using the data of distal femurs where bone transplantation is commonly performed. Experimental results show that the proposed method generally outperforms the surface-based method within modest extra time. Overall, our contour-based method is an effective complementary technique for allograft selection in the virtual bone bank.


Assuntos
Aloenxertos/anatomia & histologia , Bancos de Ossos , Transplante Ósseo , Fêmur/anatomia & histologia , Imageamento Tridimensional/métodos , Transplante Ósseo/métodos , Fêmur/transplante , Humanos , Modelos Anatômicos , Software , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS