Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 48(3): 285-296, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37431960

RESUMO

PURPOSE: A Clinical Practice Guideline (CPG) is required to provide guidance on optimal service delivery for Functional Electrical Stimulation (FES) to support upright mobility in people living with mobility difficulties due to an upper motor neuron lesion, such as stroke or multiple sclerosis. A modified Delphi consensus study was used to provide expert consensus on best practice. METHODS: A Steering Group supported the recruitment of an Expert Panel, which included a range of stakeholders who participated in up to three survey rounds. In each round, panelists were asked to rate their agreement with draft statements about best practice using a 6-point Likert scale and add free text to explain their answer. Statements that achieved over 75% agree/strongly agree on the Likert scale were included in the CPG. Those that did not were revised based on free text comments and proposed in the next survey round. RESULTS: The first round included 82 statements with seven substatements. Sixty-five people (84% response rate) completed survey round 1 leading to 62 statements and four substatements being accepted. Fifty-six people responded to survey round 2, and consensus was achieved for all remaining statements. CONCLUSION: The accepted statements are included within the CPG and provide recommendations about who can benefit from FES and how they can be optimally supported through FES service provision. As such the CPG will support advocacy for, and optimal design of, FES services.


Assuntos
Neurônios Motores , Humanos , Consenso , Técnica Delphi , Inquéritos e Questionários , Guias de Prática Clínica como Assunto
2.
Surg Radiol Anat ; 46(4): 413-424, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38480593

RESUMO

PURPOSE: In individuals who develop drop foot due to nerve loss, several methods such as foot-leg orthosis, tendon transfer, and nerve grafting are used. Nerve transfer, on the other hand, has been explored in recent years. The purpose of this study was to look at the tibial nerve's branching pattern and the features of its branches in order to determine the suitability of the tibial nerve motor branches, particularly the plantaris muscle motor nerve, for deep fibular nerve transfer. METHODS: There were 36 fixed cadavers used. Tibial nerve motor branches were observed and measured, as were the lengths, distributions, and thicknesses of the common fibular nerve and its branches at the bifurcation region. RESULT: The motor branches of the tibial nerve that supply the soleus muscle, lateral head, and medial head of the gastrocnemius were studied, and three distinct forms of distribution were discovered. The motor branch of the gastrocnemius medial head was commonly observed as the first branch to divide, and it appeared as a single root. The nerve of the plantaris muscle was shown to be split from many origins. When the thickness and length of the motor branches measured were compared, the nerve of the soleus muscle was determined to be the most physically suited for neurotization. CONCLUSION: In today drop foot is very common. Traditional methods of treatment are insufficient. Nerve transfer is viewed as an application that can both improve patient outcomes and hasten the patient's return to society. The nerve of the soleus muscle was shown to be the best candidate for transfer in our investigation.


Assuntos
Perna (Membro) , Nervo Fibular , Humanos , Perna (Membro)/inervação , Nervo Tibial , Extremidade Inferior , Tíbia , Músculo Esquelético/inervação
3.
BMC Neurol ; 21(1): 263, 2021 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-34225695

RESUMO

BACKGROUND: Over the past 20 years Functional Electrical Stimulation (FES) has grown in clinical use to support walking in people with lower limb weakness or paralysis due to upper motor neuron lesions. Despite growing consensus regarding its benefits, provision across the UK and internationally is variable. This study aimed to explore stakeholder views relating to the value of a clinical guideline focusing on service provision of FES to support walking, how people might use it and what should be included. METHODS: A mixed methods exploration sought the views of key stakeholders. A pragmatic online survey (n = 223) focusing on the study aim was developed and distributed to the email distribution list of the UK Association for Chartered Physiotherapists Interested in Neurology (ACPIN). In parallel, a qualitative service evaluation and patient public involvement consultation was conducted. Two group, and seven individual interviews were conducted with: FES-users (n = 6), their family and carers (n = 3), physiotherapists (n = 4), service providers/developers (n = 2), researchers (n = 1) and distributors of FES (n = 1). Descriptive analysis of quantitative data and framework analysis of qualitative data were conducted. RESULTS: Support for clinical guideline development was clear in the qualitative interviews and the survey results. Survey respondents most strongly endorsed possible uses of the clinical guideline as ensuring best practice and supporting people seeking access to a FES service. Data analysis and synthesis provided clear areas for inclusion in the clinical guidelines, including current research evidence and consensus relating to who is most likely to benefit and optimal service provision as well as pathways to access this. Specific areas for further investigation were summarised for inclusion in the first stage of a Delphi consensus study. CONCLUSIONS: Key stakeholders believe in the value of a clinical guideline that focuses on the different stages of service provision for FES to support walking. A Delphi consensus study is being planned based on the findings.


Assuntos
Terapia por Estimulação Elétrica , Reabilitação Neurológica/métodos , Caminhada/fisiologia , Humanos , Guias de Prática Clínica como Assunto
4.
Acta Neurol Scand ; 143(5): 545-553, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33270229

RESUMO

INTRODUCTION: Although the effectiveness of mirror therapy (MT) has been proved in stroke persons, there is no scientific evidence about the results in people with multiple sclerosis. The aim was to investigate whether adding MT to exercise training and neuromuscular electrical stimulation (NMES) has any effect on clinical measurements, mobility, and functionality in people with multiple sclerosis (MS). METHODS: Ambulatory people with MS, with unilateral drop foot, were included. MT group (n = 13) applied bilateral ankle exercise program with mirror following NMES for 3 days a week at hospital and exercise program for 2 days a week at home. Control group (n = 13) performed same treatment without mirror box (6 weeks). The later 6 weeks both groups performed only exercise program. Clinical measurements included proprioception, muscle tone of plantar flexor muscles (MAS), muscle strength of dorsiflexor, ankle angular velocity, and range of motion (ROM) of ankle. Functionality (Functional Independence Measurement-FIM), mobility (Rivermead Mobility Index-RMI), ambulation (Functional Ambulation Scale-FAS), duration of stair climb test, and 25-foot walking velocity were assessed at the beginning, in 6th and 12th weeks. RESULTS: More positive improvements were obtained in MT group than control group in terms of range of motion (0.012), muscle strength (0.008), proprioception (0.001), 25 feet walking duration (0.015), step test duration (0.001), FAS (0.005), RMI (0.001), and FIM (0.001) after 6 weeks treatment. It was seen that this improvement maintained to 12th week on all clinical and functional measurements (p < .05). CONCLUSION: The trial revealed that adding MT to exercise training and NMES has more beneficial effects on clinical measurements, mobility, and functionality in people with multiple sclerosis with unilateral drop foot.


Assuntos
Terapia por Exercício/métodos , Esclerose Múltipla/complicações , Esclerose Múltipla/reabilitação , Neuropatias Fibulares/etiologia , Neuropatias Fibulares/reabilitação , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Resultado do Tratamento
5.
Acta Neurochir (Wien) ; 162(6): 1439-1444, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32328792

RESUMO

BACKGROUND: Common fibular (peroneal) nerve (CFN) entrapment is the most frequent nerve entrapment in the lower extremity. It can cause pain, sensory abnormalities, and reduced ability to dorsiflex the foot or a drop foot. A simple test to assist with diagnosis of CFN entrapment is described as an adjunctive clinical tool for the diagnosis of CFN entrapment and also as a predictor of successful surgical decompression of a CFN entrapment. METHODS: The test, a lidocaine injection into the peroneus longus muscle at the site of a common fibular nerve entrapment, was studied retrospectively in 21 patients who presented with a clinical suspicion of CFN entrapment. Patients ages ranged from 17 to 71 (mean 48.5). RESULTS: The lidocaine injection test (LIT) was positive in 19 patients, and of these, 17 underwent surgical decompression and subsequently experienced improved ability to dorsiflex their foot and reduced sensory abnormalities. CONCLUSION: The LIT is a simple, safe adjunctive test to help diagnose and also predict a successful outcome of surgical decompression of a CFN entrapment. The proposed mechanism of action of the LIT could lead to new, non-surgical treatments for CFN entrapment.


Assuntos
Descompressão Cirúrgica/métodos , Hipestesia/etiologia , Neuropatias Fibulares/diagnóstico , Complicações Pós-Operatórias/etiologia , Adulto , Descompressão Cirúrgica/efeitos adversos , Feminino , Humanos , Hipestesia/epidemiologia , Masculino , Pessoa de Meia-Idade , Nervo Fibular/cirurgia , Neuropatias Fibulares/cirurgia , Complicações Pós-Operatórias/epidemiologia
6.
Med J Islam Repub Iran ; 34: 173, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33816372

RESUMO

Background: Drop foot syndrome is a disorder characterized by foot slapping after the initial contact and foot-dragging during the swing phase. Passive and hybrid passive ankle foot orthoses (AFOs) are often prescribed in these patients; however, the effects of these AFO designs on kinematic parameters during gait are unclear. The aim of this study was to compare the effect of innovative designed storing-restoring hybrid passive AFOs versus posterior leaf spring AFO on ankle joint kinematics in drop foot patients. Methods: The present study was a case series where a single case and 3 cases with drop foot syndrome were recruited. This study was designed in 2 phases: the baseline phase with their PLS AFOs and an intervention phase in which innovative designed AFO were assessed. Each phase included 5 measurement sessions which were performed in 5 consecutive weeks. The celeration line method was used to detect the significant differences between the phases. Results: The results of this study showed a significant increase in the kinematic angles parameters at the initial contact, the loading response, the mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing with the innovative designed AFO than with PLS AFO (p<0.05). Conclusion: The results of the present study suggested that use of the innovative designed AFO may have a positive effect on ankle joint kinematics parameters in people with drop foot.

7.
Med J Islam Repub Iran ; 34: 115, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33315978

RESUMO

Background: Ankle Foot Orthosis (AFOs) are frequently prescribed in the management of drop-foot patients. However, few studies have examined the benefits of different design of Ankle Foot Orthosis with extra elements like dampers or springs. Therefore, the objective of this study was to investigate the efficacy of articulated Ankle Foot Orthosis with Hydra pneumatic damper, in kinetic, kinematic and spatiotemporal parameters of drop foot patients. Methods: Ten drop foot patients were recruited for this study, walked at self-selected comfortable speed. A three-dimensional motion analysis, were used for obtaining kinetic, spatio-temporal and kinematic gait parameters. Results: The articulated Ankle Foot Orthosis with Hydra pneumatic damper was significantly improved speed, cadence, step length of walking (p<0.005). Furthermore, the peak and mean of moment, push off velocity and energy storing/returning were significantly improved by articulated Ankle Foot Orthosis with Hydra pneumatic damper (p<0.005). Conclusion: The newly designed articulated Ankle Foot Orthosis with Hydra pneumatic damper improved the ankle moment in at the loading response, power generation and the ankle range in drop foot patient.

8.
J Foot Ankle Surg ; 58(2): 213-220, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30554867

RESUMO

Rupture of the tibialis anterior tendon is a rare condition reported to occur most often spontaneously in patients >45 years of age. Diagnosis is often delayed due to transient pain at the time of rupture and the ability of the long extensors to compensate for the lost action of the tibialis anterior. Treatment has been proposed to be based on the activity level of the individual; however, no consensus has been reached on the optimal treatment modality for this rare condition. A systematic review and meta-analysis were performed to determine outcomes obtained with conservative and surgical management. Twenty-four references (155 cases) were identified. Conservative management (21 cases, 13.55%) was associated with poorer outcomes (odds ratio [OR] 0.68; I2 = 61%) because of pain and functional limitations related to ankle dorsiflexory weakness. Surgical intervention (134 cases, 86.45%) had a better chance for good outcome (OR 8.40; I2 = 63%). Use of an ipsilateral split/turn-down ipsilateral tibialis anterior tendon graft (OR 32.15; I2 = 0%) semitendinous autograft (OR 15.25; I2 = 44%), or direct repair (OR 12.57; I2 = 0%) provided the best postoperative outcomes, whereas extensor hallucis longus autograft was associated with the worst (OR 0.27, I2 = 34%). The most common postoperative finding was objective mild dorsiflexory weakness (4/5 muscle strength), which did not translate to subjective functional limitation. Good functional results were found to occur regardless of patient age at the time of intervention. Results of this systematic review and meta-analysis suggests that surgical intervention provides better functional outcomes than conservative management. Use of an extensor hallucis longus autograft is not recommended if surgical intervention is performed.


Assuntos
Traumatismos dos Tendões/reabilitação , Traumatismos dos Tendões/cirurgia , Transferência Tendinosa/métodos , Tratamento Conservador/métodos , Feminino , Seguimentos , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Recuperação de Função Fisiológica , Fatores de Risco , Ruptura/diagnóstico por imagem , Ruptura/cirurgia , Traumatismos dos Tendões/diagnóstico por imagem , Tíbia , Resultado do Tratamento
9.
Ideggyogy Sz ; 72(9-10): 353-356, 2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31625702

RESUMO

Drop foot is defined as difficulty of dorsiflexion of the foot and ankle due to weak anterior tibial, extensor hallucis longus and extensor digitorum longus muscles. Cauda equina syndrome, local peroneal nerve damage due to trauma, nerve entrapment, compartment syndrome and tumors are common etiologies. A 32-year-old male patient was applied with difficulty in dorsiflexion of both of his toes, feet and ankles after he had squatted in toilette for 6-7 hours (because of his haemorrhoid) after intense alcohol intake 2 weeks before. Acute, partial, demyelinating lesion in head of fibula segment of peroneal nerves was diagnosed by electromyography. This case was reported since prolonged squatting is an extremely rare cause of acute bilateral peroneal neuropathy. This type of neuropathy is mostly demyelination and has good prognosis with physical therapy and mechanical devices, but surgical intervention may be required due to axonal damage. People such as workers and farmers working in the squatting position for long hours should be advised to change their position as soon as the compression symptoms (numbness, tingling) appear.


Assuntos
Hemorroidas/complicações , Nervo Fibular/fisiopatologia , Neuropatias Fibulares/diagnóstico , Postura/fisiologia , Adulto , Eletromiografia , Pé/irrigação sanguínea , Humanos , Masculino , Músculo Esquelético , Nervo Fibular/cirurgia , Neuropatias Fibulares/etiologia , Neuropatias Fibulares/cirurgia
10.
Clin Anat ; 30(8): 1083-1086, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28726265

RESUMO

In anterior transfer of the tibialis posterior tendon, the tendon was harvested using two incisions, the first at its attachment point on the navicular bone and second on the medial side of the leg above the medial malleolus. To provide the maximum tendon length, the second incision needs to be as proximal as possible but injury to the muscle origin must be avoided. The purpose of this study is to establish the location of the second incision that yields the greatest tendon length. Forty-five unpaired embalmed cadaveric legs were dissected. Demographic data, gender, age, and side of specimen were recorded. The distance between the tip of the medial malleolus and the muscle origin was measured. Mobile tendon length, muscle origin, foot length, tibial length, and position of ankle were also noted. The mean mobile tendon length was 11.1 (range 10.7-11.4) cm and the distance between the tip of the medial malleolus and the muscle origin was 6.8 (range 6.5-7.0) cm. The mean foot length was 22.2 cm (range 21.7-22.7), tibial length was 31.5 cm (range 30.8-32.2), and muscle origin was 23.7 cm (range 21.0-26.3). The mean angle position was 46 degrees plantar flexion (range 43-49). In subgroup analysis by gender, the mobile tendon length, distance between the tip of the medial malleolus and the muscle origin, and tibial length, were significantly greater in males than females. In conclusion, for anterior transfer of the tibialis posterior tendon, an incision 7.1 cm above the medial malleolus in the male and 6.4 cm above it in the female provides the longest mobile tendon without injury to its origin. Clin. Anat. 30:1083-1086, 2017. © 2017 Wiley Periodicals, Inc. LEVEL OF EVIDENCE: V, Cadaveric descriptive study.


Assuntos
Transferência Tendinosa/métodos , Tendões/anatomia & histologia , Coleta de Tecidos e Órgãos/métodos , Articulação do Tornozelo/anatomia & histologia , Cadáver , Dissecação , Feminino , Humanos , Extremidade Inferior/anatomia & histologia , Masculino , Tendões/transplante , Tíbia/anatomia & histologia
11.
Arch Orthop Trauma Surg ; 137(4): 499-506, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28220261

RESUMO

INTRODUCTION: Unlike the drop foot therapy with ortheses, the therapeutic effect of an implantable peroneus nerve stimulator (iPNS) is not well described. IPNS is a dynamic therapy option which is placed directly to the motoric part of the peroneal nerve and evokes a dorsiflexion of the paralysed foot. This retrospective study evaluates the kinematics and kinetics in drop foot patients who were treated with an iPNS. MATERIALS AND METHODS: 18 subjects (mean age 51.3 years) with a chronic stroke-related drop foot were treated with an implantable peroneal nerve stimulator. After a mean follow-up from 12.5 months, kinematics and kinetics as well as spatiotemporal parameters were evaluated and compared in activated and deactivated iPNS. Therefore, a gait analysis with motion capture system (Vicon Motion System Ltd®, Oxford, UK) and Plug-in-Gait model was performed. RESULTS: The study showed significantly improved results in ankle dorsiflexion from 6.8° to 1.8° at the initial contact and from -7.3° to 0.9° during swing phase (p ≤ 0.004 and p ≤ 0.005, respectively). Likewise, we could measure improved kinetics, i.a. with a statistically significant improvement in vertical ground reaction force at loading response from 99.76 to 106.71 N/kg (p = 0.043). Enhanced spatiotemporal results in cadence, douple support, stride length, and walking speed could also be achieved, but without statistical significance (p > 0.05). CONCLUSIONS: The results show statistically significant improvement in ankle dorsiflexion and vertical ground reaction forces. These facts indicate a more gait stability and gait efficacy. Therefore, the use of an iPNS appears an encouraging therapeutic option for patients with a stroke-related drop foot.


Assuntos
Terapia por Estimulação Elétrica/métodos , Transtornos Neurológicos da Marcha/terapia , Nervo Fibular , Acidente Vascular Cerebral/terapia , Adulto , Tornozelo/fisiologia , Fenômenos Biomecânicos , Feminino , Pé/fisiologia , Marcha/fisiologia , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Estudos Retrospectivos , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
12.
Orthopade ; 46(3): 227-233, 2017 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-27995271

RESUMO

INTRODUCTION: Neurologic paralysis of the foot due to damage to the central nervous system is primarily caused by a cerebral insult. The ankle-foot orthosis (AFO), which is the classical conservative treatment option, is associated with drawbacks, e.g., increased contractures, limited mobilization from the sitting position, and cosmetic aspects. METHODS: Functional external electrostimulation (FES) is an suitable treatment method for patients with a central lesion and intact peroneal nerve. Based on this method, the neuroprosthesis is a dynamic therapy option in the form of an implantable nerve stimulator (ActiGait® system, Otto Bock, Duderstadt, Germany) which is placed directly on the motor branch of the peroneus nerve and results in active foot lifting. The aim of the present study is to evaluate the clinical effect of the ActiGait® system with regard to its suitability for everyday use by means of gait tests with an emphasis on time-distance parameters and to compare it with the current literature. RESULTS AND CONCLUSION: In this retrospective study, the clinical results after implantation of the ActiGait® system are presented and evaluated. In summary, the implantation of a neuroprosthesis in patients with stroke-related drop foot represents a sensible and promising therapy option.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Pé/inervação , Transtornos Neurológicos da Marcha/diagnóstico , Transtornos Neurológicos da Marcha/reabilitação , Reabilitação Neurológica/instrumentação , Próteses e Implantes , Adulto , Idoso , Terapia por Estimulação Elétrica/métodos , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reabilitação Neurológica/métodos , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
13.
J Foot Ankle Surg ; 56(1): 103-107, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27989337

RESUMO

Peroneal nerve palsy is common. The hallmark clinical manifestation of peroneal nerve palsy is drop foot. In the drop foot condition, the ankle cannot flex, and the foot does not clear the ground during the swing phase of gait. Spontaneous nerve repair can yield complete or incomplete resolution of drop foot. Some patients with incomplete resolution are left with a drop hallux condition, in which the ankle can dorsiflex, but the hallux remains unable to dorsiflex. This has not been thoroughly discussed in the past, regarding surgical repair. In the present report, we have reviewed the drop hallux condition and an effective surgical repair option (extensor hallucis longus to tibialis anterior tendon anastomosis). Our case report presents a healthy 27-year-old male who had persistent drop hallux after drop foot resolution, 3 years after external fixation of a closed, proximal tibia-fibula fracture.


Assuntos
Fixadores Externos , Deformidades Adquiridas do Pé/cirurgia , Fixação de Fratura/efeitos adversos , Neuropatias Fibulares/cirurgia , Transferência Tendinosa/métodos , Fraturas da Tíbia/cirurgia , Adulto , Seguimentos , Deformidades Adquiridas do Pé/diagnóstico por imagem , Deformidades Adquiridas do Pé/etiologia , Fixação de Fratura/instrumentação , Transtornos Neurológicos da Marcha/prevenção & controle , Transtornos Neurológicos da Marcha/cirurgia , Hallux/fisiopatologia , Hallux/cirurgia , Humanos , Masculino , Neuropatias Fibulares/etiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Recuperação de Função Fisiológica , Futebol/lesões , Fraturas da Tíbia/diagnóstico por imagem , Resultado do Tratamento
14.
Artif Organs ; 40(11): 1085-1091, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27121484

RESUMO

We evaluated the efficacy and robustness of a second generation implantable stimulator for correcting drop foot (DF) in a patient with left-sided hemiplegia over 20 years of functional electrical stimulation (FES) of the common peroneal nerve (CPN). Dorsal flexion and eversion of the affected foot was partially restored by FES of the superficial region of the CPN innervating mostly the tibialis anterior (TA) and partly peroneus longus (PL) and peroneus brevis (PB) muscles. The reasons for implant failure during the long-term follow-up assessment were analyzed and resolving procedures were identified. The stimulator had an average failure rate of once every three years, due to repetitive mechanical load on the lead wires of its internal and/or external unit, and had to be serviced once per year to replace the heel switch integrated into the shoe sole. FES-associated mechanical trauma to the CPN elicited a thickening of the connective tissue around the CPN and a slightly compromised conduction velocity of the CPN. FES of the CPN, with the second generation implantable stimulator, improved gait parameters of the affected leg during the 20 years period. Long-term, daily FES enables a functional and reliable recruitment of nerve fibers, thus providing a sufficient dorsal flexion and optimal eversion of the affected foot to sustain unassisted, almost normal gait. Therefore, the presented implant is suitable for very long-term FES of the CPN.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Transtornos Neurológicos da Marcha/terapia , Hemiplegia/terapia , Neuroestimuladores Implantáveis , Neuropatias Fibulares/terapia , Reabilitação do Acidente Vascular Cerebral/instrumentação , Acidente Vascular Cerebral/complicações , Adulto , Terapia por Estimulação Elétrica/efeitos adversos , Seguimentos , Pé/inervação , Transtornos Neurológicos da Marcha/etiologia , Hemiplegia/etiologia , Humanos , Perna (Membro)/inervação , Músculo Esquelético/inervação , Nervo Fibular/lesões , Neuropatias Fibulares/etiologia , Falha de Prótese , Reabilitação do Acidente Vascular Cerebral/métodos , Resultado do Tratamento
15.
Foot Ankle Surg ; 22(3): 196-199, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27502230

RESUMO

BACKGROUND: Tibialis posterior (TP) tendon transfer through the interosseous membrane is commonly performed in Charcot-Marie-Tooth disease. In order to avoid entrapment of this tendon, no clear recommendation relative to the interosseous membrane (IOM) incision size has been made. OBJECTIVE: Analyze the TP size at the transfer level and therefore determine the most adequate IOM window size to avoid muscle entrapment. METHODS: Eleven lower extremity magnetic resonances were analyzed. TP muscle measurements were made in axial views, obtaining the medial-lateral and antero-posterior diameter at various distances from the medial malleolus tip. The distance from the posterior to anterior compartment was also measured. These measurements were applied to a mathematical model to predict the IOM window size necessary to allow an ample TP passage in an oblique direction. RESULTS: The average tendon diameter (confidence-interval) at 15cm proximal to the medial malleolus tip was 19.47mm (17.47-21.48). The deep posterior compartment to anterior compartment distance was 10.97mm (9.03-12.90). Using a mathematical model, the estimated IOM window size ranges from 4.2 to 4.9cm. CONCLUSION: The IOM window size is of utmost importance in trans-membrane TP transfers, given that if equal or smaller than the transposed tendon oblique diameter, a high entrapment risk exists. A membrane window of 5cm or 2.5 times the size of the tendon diameter should be performed in order to theoretically diminish this complication.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Disfunção do Tendão Tibial Posterior/diagnóstico por imagem , Disfunção do Tendão Tibial Posterior/cirurgia , Transferência Tendinosa/métodos , Adolescente , Adulto , Articulação do Tornozelo/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Complicações Pós-Operatórias/prevenção & controle , Prognóstico , Medição de Risco , Estudos de Amostragem , Resultado do Tratamento , Adulto Jovem
16.
Arch Phys Med Rehabil ; 96(4): 667-72, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25499688

RESUMO

OBJECTIVE: To determine the effectiveness of functional electrical stimulation (FES) on drop foot in patients with multiple sclerosis (MS), using data from standard clinical practice. DESIGN: Case series with a consecutive sample of FES users collected between 2008 and 2013. SETTING: Specialist FES center at a district general hospital. PARTICIPANTS: Patients with MS who have drop foot (N=187) (117 women, 70 men; mean age, 55y [range, 27-80y]; mean duration since diagnosis, 11.7y [range, 1-56y]). A total of 166 patients were still using FES after 20 weeks, with 153 patients completing the follow-up measures. INTERVENTIONS: FES of the common peroneal nerve (178 unilateral, 9 bilateral FES users). MAIN OUTCOME MEASURES: Clinically meaningful changes (ie, >.05m/s and >0.1m/s) and functional walking category derived from 10-m walking speed. RESULTS: An increase in walking speed was found to be highly significant (P<.001), both initially where a minimum clinically meaningful change was observed (.07m/s) and after 20 weeks with a substantial clinically meaningful change (.11m/s). After 20 weeks, treatment responders displayed a 27% average improvement in their walking speed. No significant training effect was found. Overall functional walking category was maintained or improved in 95% of treatment responders. CONCLUSIONS: FES of the dorsiflexors is a well-accepted intervention that enables clinically meaningful changes in walking speed, leading to a preserved or an increased functional walking category.


Assuntos
Terapia por Estimulação Elétrica/métodos , Transtornos Neurológicos da Marcha/reabilitação , Esclerose Múltipla/reabilitação , Nervo Fibular , Caminhada , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Marcha , Transtornos Neurológicos da Marcha/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Modalidades de Fisioterapia
17.
Artif Organs ; 39(5): E56-66, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25919579

RESUMO

Functional electrical stimulation (FES) has been used over the last decades as a method to rehabilitate lost motor functions of individuals with spinal cord injury, multiple sclerosis, and post-stroke hemiparesis. Within this field, researchers in need of developing FES-based control solutions for specific disabilities often have to choose between either the acquisition and integration of high-performance industry-level systems, which are rather expensive and hardly portable, or develop custom-made portable solutions, which despite their lower cost, usually require expert-level electronic skills. Here, a flexible low-cost microcontroller-based platform for rapid prototyping of FES neuroprostheses is presented, designed for reduced execution complexity, development time, and production cost. For this reason, the Arduino open-source microcontroller platform was used, together with off-the-shelf components whenever possible. The developed system enables the rapid deployment of portable FES-based gait neuroprostheses, being flexible enough to allow simple open-loop strategies but also more complex closed-loop solutions. The system is based on a modular architecture that allows the development of optimized solutions depending on the desired FES applications, even though the design and testing of the platform were focused toward drop foot correction. The flexibility of the system was demonstrated using two algorithms targeting drop foot condition within different experimental setups. Successful bench testing of the device in healthy subjects demonstrated these neuroprosthesis platform capabilities to correct drop foot.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Transtornos Neurológicos da Marcha/terapia , Adulto , Idoso , Terapia por Estimulação Elétrica/economia , Desenho de Equipamento , Marcha , Transtornos Neurológicos da Marcha/complicações , Humanos , Masculino , Esclerose Múltipla/complicações , Software , Traumatismos da Medula Espinal/complicações , Acidente Vascular Cerebral/complicações
18.
Neuromodulation ; 17(1): 75-84; discussion 84, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23601128

RESUMO

OBJECTIVE: To examine the effect of Functional Electrical Stimulation (FES) for dropped foot and hip instability in combination with physiotherapy core stability exercises. METHODS: Twenty-eight people with secondary progressive multiple sclerosis and unilateral dropped foot participated in a randomized crossover trial. Group1 received FES for correction of dropped foot for six weeks with the addition of hip extension for a further six weeks. In weeks 12-18, FES was continued with the addition of eight sessions of core stability physiotherapy with home-based exercise. FES and home-based exercise were continued until weeks 19-24. Group 2 received the same physiotherapy intervention over the first 12 weeks, adding FES in the second 12 weeks. RESULTS: FES improved walking speed and Rivermead Observational Gait Analysis (ROGA) score, whereas physiotherapy did not. Adding gluteal stimulation further improved ROGA score. Both interventions reduced falls, but adding FES to physiotherapy reduced them further. FES had greater impact on Multiple Sclerosis Impact Scale, MSIS-29. CONCLUSION: The intervention was feasible. FES for dropped foot may improve mobility and quality of life and may reduce falls. Adding gluteal stimulation further improved gait quality. Adding physiotherapy may have enhanced the effect of FES, but FES had the dominant effect.


Assuntos
Terapia por Estimulação Elétrica , Transtornos Neurológicos da Marcha/terapia , Esclerose Múltipla Crônica Progressiva/complicações , Modalidades de Fisioterapia , Acidentes por Quedas/prevenção & controle , Acidentes por Quedas/estatística & dados numéricos , Idoso , Estudos Cross-Over , Estudos de Viabilidade , Feminino , Transtornos Neurológicos da Marcha/etiologia , Serviços de Assistência Domiciliar , Humanos , Masculino , Pessoa de Meia-Idade , Tecnologia Assistiva/estatística & dados numéricos , Índice de Gravidade de Doença , Método Simples-Cego , Resultado do Tratamento , Gravação em Vídeo , Caminhada
19.
Foot Ankle Spec ; : 19386400241235831, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500002

RESUMO

Tibialis anterior tendon (TAT) ruptures are rare, equating to less than 1% of all musculotendinous injuries. These injuries can be acute or atraumatic, with the latter often associated with chronic degenerative tendinopathy. Surgical repair is indicated when conservative measures fail in meeting functional demands. Direct end-to-end repair is the preferred method for TAT ruptures but may not be feasible with a large tendon defect. Various surgical techniques have been described to address this pathology, including allograft tendon interposition or extensor hallucis longus (EHL) transfer. The authors present a unique technique utilizing a minimal incision TAT turn-down with dermal matrix allograft augmentation, and, in addition, a case implementing this technique in a patient with a large insertional defect. The patient's postoperative course and outcomes were favorable, with improvements in pain, satisfaction, functional scores, and strength. The surgical technique offers versatility and can be adapted to different tendon defect sizes. It also allows for minimal-incision exposure, beneficial for patients with comorbidities or compromised skin integrity. In conclusion, the authors present a case report and surgical technique for the management of large-deficit, chronic TAT ruptures using split TAT turn-down. This technique provides a potential solution for cases where direct end-to-end repair is not feasible.Level of Evidence: Level V.

20.
J Nippon Med Sch ; 90(2): 237-239, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35082210

RESUMO

OBJECTIVE: Common peroneal nerve (C-PN) entrapment neuropathy is the most common peripheral nerve neuropathy of the legs. C-PN decompression surgery is less invasive but may result in neurological complications. We report a rare case of nerve paralysis immediately after C-PN decompression surgery. CASE REPORT: An 85-year-old man presented with leg numbness and pain. An electrophysical study revealed C-PN entrapment in the affected area and he underwent surgical decompression. Immediately after the procedure he complained of slight paralysis without pain (manual muscle test: 3/5), which gradually worsened and was complete at 60 min after surgery. We re-opened the skin incision 3 hours after the first operation and found that a subcutaneous suture had been applied to the connective tissue near the C-PN, resulting in marked compression of the nerve. After release of the suture his paralysis improved immediately. We confirmed that there was no other nerve compression and finished the operation. His paralysis disappeared completely. CONCLUSION: Peripheral nerve surgery, including C-PN decompression surgery, is less invasive, and the risk of complications is low. However, because the C-PN is located in the shallow layer under the skin, an excessively deep suture in the subcutaneous layer may compress the nerve and elicit nerve palsy. Therefore, careful postoperative follow-up is necessary because early decompression leads to good surgical results.


Assuntos
Doenças do Sistema Nervoso Periférico , Neuropatias Fibulares , Masculino , Humanos , Idoso de 80 Anos ou mais , Neuropatias Fibulares/etiologia , Neuropatias Fibulares/cirurgia , Paralisia/etiologia , Paralisia/cirurgia , Dor , Descompressão Cirúrgica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA