Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 33(2): 409-416, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37748530

RESUMO

BACKGROUND: Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and a less prominent and optimized plate-to-bone fit design. On the other hand, minifragment plates in dual plating mode have demonstrated promising clinical results. The aim of the current study was to compare the biomechanical competence of single superior plating using the new-generation plate vs. dual plating using low-profile minifragment plates. METHODS: Sixteen paired human cadaveric clavicles were pairwise assigned to 2 groups for instrumentation with either a superior 2.7-mm variable-angle locking compression plate (group 1), or with one 2.5-mm anterior combined with one 2.0-mm superior matrix mandible plate (group 2). An unstable clavicle shaft fracture (AO/OTA 15.2C) was simulated by means of a 5-mm osteotomy gap. Specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis, and monitored via motion tracking. RESULTS: Initial construct stiffness was significantly higher in group 2 (9.28 ± 4.40 N/mm) compared to group 1 (3.68 ± 1.08 N/mm), P = .003. The amplitudes of interfragmentary motions in terms of axial and shear displacement, fracture gap opening and torsion, over the course of 12,500 cycles were significantly higher in group 1 compared to group 2, P ≤ .038. Cycles to 2 mm shear displacement were significantly lower in group 1 (22,792 ± 4346) compared to group 2 (27,437 ± 1877), P = .047. CONCLUSION: From a biomechanical perspective, low-profile 2.5/2.0-mm dual plates could be considered as a useful alternative for diaphyseal clavicle fracture fixation, especially in less common unstable fracture configurations.


Assuntos
Clavícula , Fraturas Ósseas , Humanos , Clavícula/cirurgia , Fenômenos Biomecânicos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Placas Ósseas
2.
Arch Orthop Trauma Surg ; 144(3): 1211-1220, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38265463

RESUMO

INTRODUCTION: This study described a deformity induced by medial plating of supracondylar distal femur fractures using plates that are precontoured for other anatomic locations. MATERIALS AND METHODS: OTA/AO 33A fractures were created in 12 sawbone femurs and fixed with either a proximal humerus locking plate (PH), an ipsilateral lateral tibial plateau plate (LTP), or an ipsilateral medial distal tibial plate (MDT). A motion capture system measured changes in length and rotation of the distal femur as the plate was applied. Each plate underwent four trials and the mean and standard deviation (SD) for each measurement was reported. An analysis of variance with post hoc Tukey test compared malreduction measures between plate types. RESULTS: All plates consistently created a varus deformity. There was lateral lengthening with a compensatory medial shortening and an increase in the lateral distal femoral angle. The distal fracture fragment was laterally translated, and internally rotated. The PH plate had significantly greater lateral length (27.39 mm SD 4.78, p = 0.007), shorter medial length (13.57 mm SD 4.99, p = 0.028), greater lateral translation (28.82 mm SD 5.70, p = 0.010) and greater widening of the lateral distal femoral angle (28.54° SD 4.98, p < 0.001) than the LTP and MDT plates. The MDT plate had significantly greater angulation anteriorly (8.40° SD 1.07, p < 0.001) and laterally (7.63° SD 3.10, p = 0.002) than the PH and LTP plates. There was no significant difference between plates in internal rotation (PH: 3.07° SD 2.79; LTP: 2.05° SD 1.05; MDT 3.81° SD 3.56; p = 0.659). CONCLUSION: When dual plating supracondylar distal femur fractures, poor plate positioning and a mismatch between plate contour and the slope of the medial distal femur can lead to varus angulation, internal rotation, and lateral translation or a "reverse golf club deformity". After comparing three types of precontoured plates, the authors recommend initial evaluation of the ipsilateral proximal tibial plate when placing a plate along the medial distal femur. LEVEL OF EVIDENCE: IV.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Golfe , Humanos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fêmur , Placas Ósseas
3.
Eur J Orthop Surg Traumatol ; 34(1): 605-612, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37661241

RESUMO

INTRODUCTION: Fixation of distal femur fractures with a lateral pre-contoured locking plate provides stable fixation and is the standard treatment in most cases, allowing early range of motion with a high rate of union. However, in situations, the stability achieved with the lateral plate alone may be insufficient, predisposing to fixation failure. The objective of the study was to compare, in synthetic bone models, the biomechanical behaviour of the fixation with a distal femur lateral pre-contoured locking plate solely and associated with a 3.5 mm proximal humeral locking plate applied upside down or a 4.5 mm helical locking compression plate on the medial side. MATERIAL AND METHODS: A total of 15 solid synthetic left femur samples were used. A metaphysical defect at the level of the medial cortex was simulated. The samples were randomly distributed into three groups equally. All groups received a 4.5/5.0 mm single lateral 9-hole distal femur lateral pre-contoured locking plate. Group 1 had no supplementary plate. Group 2 received a supplementary 6-hole 3.5 mm proximal humeral locking plate and Group 3 received a supplementary 4.5/5.0 mm helical 14-hole narrow locking compression plate. RESULTS: Both supplementary plate types used in groups 2 and 3 contributed to increase the apparent stiffness of the construct, but pairwise comparison showed statically significant difference only between group 1 and 3. No significant difference was observed between groups 2 and 3. CONCLUSION: Both supplementary plates might be considered for improving the fixation in distal femur fracture in selected cases.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Humanos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fenômenos Biomecânicos , Fêmur/cirurgia , Placas Ósseas
4.
Arch Orthop Trauma Surg ; 143(8): 4653-4661, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36598604

RESUMO

INTRODUCTION: Screw cut out and varus collapse are the most common complication of locked plate fixation of proximal humerus fractures. The purpose of this study was to compare dual plating and endosteal fibular allograft struts as augmentation strategies to prevent varus collapse. MATERIALS AND METHODS: A trapezoidal osteotomy was created at the metaphysis to create a 2-part proximal humerus model in 18 paired shoulder specimens. Each specimen was assigned to group A, B, or C and was fixed with either a lateral locking plate, a lateral locking plate and anterior one-third tubular plate in an orthogonal 90/90 configuration, or a lateral locking plate with intramedullary fibular strut, respectively. The specimens were stressed in axial compression to failure. Displacement, elastic limit, ultimate load, and stiffness were recorded and calculated. RESULTS: There was no difference in mean cyclic displacement between the three groups (0.71 mm vs 0.89 mm vs 0.61 mm for Group A, B, C, respectively). Lateral plating demonstrated the greatest absolute and relative displacement at the elastic limit (5.3 mm ± 1.5 and 4.4 mm ± 1.3) without significance. The elastic limit or yield point was greatest for fibular allograft, Group C (1223 N ± 501 vs 1048 N ± 367 for Group B and 951 N ± 249 for Group A) without significance. CONCLUSIONS: Dual plating of proximal humerus fractures in a 90-90 configuration demonstrates similar biomechanical properties as endosteal fibular strut allograft. Both strategies demonstrate superior stiffness to isolated lateral locked plating.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Fixação Interna de Fraturas , Úmero/cirurgia , Fraturas do Ombro/cirurgia , Placas Ósseas , Fraturas do Úmero/cirurgia , Aloenxertos , Fenômenos Biomecânicos
5.
Eur J Orthop Surg Traumatol ; 33(2): 425-433, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35061100

RESUMO

PURPOSE: Nonunion is a common complication after a distal femoral fracture (DFF). Standard treatment consists of revision plating and/or bone grafting. Single lateral plating for a distal femoral nonunion can be insufficient in case of a persistent medial gap and compromised bone stock. Alternatively, dual plating can be used to treat a distal femoral nonunion, but to date there is no Gold standard. The aim of our study was to report our results after use of a minimally invasively placed proximal humeral internal locking system (Philos) plate as a medial buttress in the treatment of a distal femoral nonunion. METHODS: Fifteen adult patients with a distal femoral nonunion were prospectively entered in a trauma database and retrospectively assessed. All patients underwent a similar operation, which included removal of failed hardware, nonunion debridement, fixation with a lateral plate, and a medial Philos plate combined with bone grafting. Data collected included union rate, time to union, complications and functional outcome. RESULTS: In twelve out of fifteen patients (80%), the fracture united after our index operation. Median time to union was 4.8 months (range 1.6-15). Three patients (20%) needed additional bone grafting surgery. One patient underwent a Judet quadricepsplasty. CONCLUSION: This study suggests that the Philos plate is a safe and effective adjunct as a medial buttress plate for distal femoral nonunions.


Assuntos
Fraturas do Fêmur , Fraturas não Consolidadas , Adulto , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Consolidação da Fratura , Fraturas não Consolidadas/etiologia , Úmero , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas do Fêmur/etiologia , Placas Ósseas/efeitos adversos
6.
Eur J Orthop Surg Traumatol ; 33(6): 2541-2546, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36635567

RESUMO

PURPOSE: Comminution is an aspect of periprosthetic distal femoral fractures (PDFFs) that can influence postoperative outcomes and treatment selection, but is not included in current classification systems. We propose a new classification system for PDFFs based on comminution and cortical reads. This study aims to prove its reliability and efficacy to predict fracture severity and guide treatment. METHODS: A retrospective chart review of patients treated with single or dual locking plates for PDFFs was performed. Two fellowship-trained orthopedic joint reconstruction specialists used available imaging to classify each PDFF as either type 1 (minimal or no comminution allowing for reconstruction of medial and lateral cortices), type 2 (comminution reasonably allowing for reconstruction of either medial or lateral cortex), and type 3 (extensive comminution not allowing reasonable reconstruction of medial or lateral cortex). Each PDFF was then analyzed for radiographic outcomes including lateral distal femoral angle (LDFA) and the posterior distal femoral angle (PDFA). RESULTS: Interobserver reliability assessed by Cohen's Kappa statistic was 0.707, and average intraobserver reliability was 0.843, showing substantial reliability. Type 3 PDFFs had greater varus deformity than type 1 (p = 0.0457) or 2 (0.0198). CONCLUSION: The proposed classification system accounts for comminution, demonstrates strong interobserver and intraobserver reliability, and can be used to guide treatment in regard to single versus dual plating. LEVEL OF EVIDENCE: Retrospective comparative study, Level IV.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Fraturas Cominutivas , Fraturas Periprotéticas , Humanos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Fêmur , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas
7.
J Hand Surg Am ; 47(8): 796.e1-796.e6, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35031124

RESUMO

PURPOSE: Comminuted olecranon fractures are commonly fixed with posterior locking plates (PLPs). Though biomechanically validated, this method comes with risks of symptomatic implant prominence and wound breakdown. Dual locking plates (DLPs) placed on the medial and lateral surfaces of the olecranon theoretically avoid these risks and allow for fixation of proximal fracture fragments in multiple planes. A biomechanical comparison of DLP and PLP fixation would help to validate the use of DLPs in comminuted olecranon fractures. METHODS: Seven matched pairs of cadaveric upper extremities were evaluated with quantitative computed tomography scans to evaluate bone mineral density (BMD). Osteotomies simulating comminuted olecranon fractures (Mayo Type IIB) were created and the specimens were fixed either with variable angle PLPs or variable angle DLPs. The specimens were then cyclically loaded and loaded to failure. The ultimate strength, fracture displacement, and mechanism of failure were recorded and compared across groups. The correlation between BMD and ultimate strength was analyzed. RESULTS: The mean total BMD was 0.79 g/cm2 (SD, 0.14 g/cm2). No specimen failed during cyclic testing. Five of 7 PLP specimens and 5 of 7 DLP specimens failed by fracture through the proximal screws though in different planes (sagittal vs axial splits, respectively). The mean ultimate strengths of the PLP (1077 N [SD, 462 N]) and DLP (1241 N [SD, 506 N]) groups were similar. There was a linear relationship between ultimate strength and BMD (R2 = 0.33). CONCLUSION: Dual locking plates display biomechanical properties that suggest that they can be used in the fixation of comminuted olecranon fractures. Catastrophic failure of the fixation constructs occurs around stress risers at the proximal screws rather than due to displacement at the fracture itself. CLINICAL RELEVANCE: Dual locking plate constructs can be considered for use in the fixation of comminuted olecranon fractures.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Olécrano , Fraturas da Ulna , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Humanos , Olécrano/cirurgia , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/cirurgia
8.
J Shoulder Elbow Surg ; 30(9): e594-e601, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33571652

RESUMO

BACKGROUND: Dual orthogonal plating of midshaft clavicle fractures is increasingly used for osteosynthesis. The risk of refracture after hardware removal remains unknown. The purpose of this study was to compare the torsional and 3-point bending loads to failure of the clavicle following removal of single-plane, superior 3.5-mm plate fixation vs. dual orthogonal plating 2.7-mm constructs. METHODS: This study used 12 pairs of clavicles (N = 24) harvested from cadaveric specimens with a mean age at death of 56.5 years (range, 46-65 years). One clavicle from each pair was randomly assigned to either superior plating (SP, n = 12) or double plating (DP, n = 12). For SP, a superior 3.5-mm plate was used as a template to drill 3 bicortical 2.8-mm holes medial and lateral to the center of the clavicle. For DP, two 2.7-mm plates were used as a template to drill 4 bicortical 2.0-mm holes medial and lateral to the center of the clavicle. Clavicle pairs were randomly and evenly distributed to undergo either 3-point bending (n = 12) or posterior torsional loading (n = 12). Cyclic loading was performed, followed by load-to-failure testing. Stiffness, displacement at failure, load to failure, and failure mode were assessed and compared between SP and DP constructs. RESULTS: No significant differences between the SP and DP groups were observed for stiffness (768.2 ± 281.3 N/mm vs. 785.5 ± 315.0 N/mm, P = .872), displacement at failure (8.1 ± 2.8 mm vs. 5.4 ± 1.2 mm, P = .150), and ultimate load at failure (1831.0 ± 229.6 N vs. 1842.0 ± 662.4 N, P = .964) under the condition of 3-point bending. Similarly, no significant differences between the SP and DP groups were observed for torsional stiffness (1.3 ± 0.8 N · m/° vs. 1.1 ± 0.4 N · m/°, P = .844), rotation at failure (17.3° ± 4.4° vs. 14.4° ± 1.2°, P = .205), and ultimate torque at failure (14.8 ± 6.5 N · m vs. 14.7 ± 6.9 N · m, P = .103) under the condition of posterior torsional loading. The most common mode of failure for 3-point bending testing was an oblique fracture (7 of 12 clavicles, 58.3%), with no significant difference between groups (3 of 6 in SP group [50%] vs. 4 of 6 in DP group [66.7%], P > .999). The most common mode of failure with posterior torsional loading was a spiral fracture (10 of 12 clavicles, 83.3%), with no significant difference between groups (4 of 6 in SP group [66.7%] vs. 6 of 6 in DP group [100%], P = .455). CONCLUSION: Following clavicle plate removal of either DP or SP, there is no statistically significant difference in the amount of force, under the condition of 3-point bending or torsional loading, required to fracture the diaphyseal clavicle in vitro.


Assuntos
Clavícula , Fraturas Ósseas , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos
9.
Angew Chem Int Ed Engl ; 58(44): 15910-15915, 2019 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-31478325

RESUMO

Plating battery electrodes typically deliver higher specific capacity values than insertion or conversion electrodes because the ion charge carriers represent the sole electrode active mass, and a host electrode is unnecessary. However, reversible plating electrodes are rare for electronically insulating nonmetals. Now, a highly reversible iodine plating cathode is presented that operates on the redox couples of I2 /[ZnIx (OH2 )4-x ]2-x in a water-in-salt electrolyte. The iodine plating cathode with the theoretical capacity of 211 mAh g-1 plates on carbon fiber paper as the current collector, delivering a large areal capacity of 4 mAh cm-2 . Tunable femtosecond stimulated Raman spectroscopy coupled with DFT calculations elucidate a series of [ZnIx (OH2 )4-x ]2-x superhalide ions serving as iodide vehicles in the electrolyte, which eliminates most free iodide ions, thus preventing the consequent dissolution of the cathode-plated iodine as triiodides.

10.
Eur J Orthop Surg Traumatol ; 28(1): 121-130, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28710534

RESUMO

INTRODUCTION: In this prospective case series, we report a mean of 12-month follow-up of the utilization of a dual plating of distal femoral fractures. Our technique included a lateral distal femoral locked plate with a low-contact-locked medial plate and bone graft through an extended medial parapatellar anterior approach for the fixation of C3-type distal femoral fractures. PATIENTS AND METHODS: Sixteen patients (11 males and 5 females) presented with supracondylar femoral fracture type C3, according to Müller long-bone classification system and its revision OA/OTA classification. These were treated using dual plating through extended anterior approach and bone grafting. Our outcomes included clinical and radiological outcomes. Secondary outcomes included postoperative complications. RESULTS: The mean time of complete radiological union in the studied population was 6.0 ± 3.5 months with a range of 3-14 months. We have not observed postoperative varus or valgus deformity in our cohort. The majority (68.75%) of the studied patients showed significant improvement in range of motion (90°-120°) during follow-up. Eleven out of sixteen patients (68.75%) had well-to-excellent functional outcome. Poor outcome was reported in only two patients (12.50%). CONCLUSIONS: Dual plating fixation using anterior approach for type C3 distal femoral fractures is an efficient method of management. It has several advantages such as precise exposure, easy manipulation, anatomical reduction and stable fixation. However, operative indications and instructions should be strictly followed. The surgical technique must be rigorous, and the biomechanical qualities of these implants must be understood to prevent the development of major complications.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Adolescente , Adulto , Placas Ósseas , Transplante Ósseo , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Seguimentos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Humanos , Imageamento Tridimensional , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
11.
Arch Orthop Trauma Surg ; 135(12): 1655-62, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26377733

RESUMO

BACKGROUND: We sought to evaluate clinical and biomechanical outcomes of dual mini-fragment plate fixation for clavicle fractures. We hypothesized that this technique would produce an anatomical reduction with good clinical outcomes, be well tolerated by patients, and demonstrate equivalent biomechanics to single plating. METHODS: Dual mini-fragment plating was performed for 17 isolated, displaced midshaft clavicle fractures. Functional outcomes and complications were retrospectively reviewed. A sawbones model compared dual plating biomechanics to a (1) superior 3.5-mm locking reconstruction plate, or (2) antero-inferior 3.5-mm locking reconstruction plate. RESULTS: On biomechanical testing, with anterior loading, dual plating was significantly more rigid than single locked anterior-plating (p = 0.02) but less rigid than single locked superior-plating (p = 0.001). With superior loading, dual plating trended toward higher rigidity versus single locked superior-plating (p = 0.07) but was less rigid than single locked anterior-plating (p = 0.03). No statistically significant differences in axial loading (p = 0.27) or torsion (p = 0.23) were detected. Average patient follow-up was 16.1 months (12-38). Anatomic reduction was achieved and maintained through final healing (average 14.7 weeks). No patient underwent hardware removal. Average 1-year DASH score was 4.0 (completed in 88 %). CONCLUSIONS: Displaced midshaft clavicle fractures can be effectively managed with dual mini-fragment plating. This technique results in high union rates and excellent clinical outcomes. Compared to single plating, dual plating is biomechanically equivalent in axial loading and torsion, yet offers better multi-planar bending stiffness despite the use of smaller plates. This technique may decrease the need for secondary surgery due to implant prominence and may aid in fracture reduction by buttressing butterfly fragments in two planes.


Assuntos
Traumatismos do Braço/cirurgia , Placas Ósseas , Clavícula/lesões , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Traumatismos do Braço/fisiopatologia , Fenômenos Biomecânicos , Clavícula/cirurgia , Desenho de Equipamento , Feminino , Fraturas Ósseas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Estudos Retrospectivos
12.
J Orthop Case Rep ; 14(3): 124-129, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560321

RESUMO

Introduction: Knee arthrodesis following failed total knee arthroplasty is a viable limb salvage option, and this procedure is reserved for failed two-stage revision surgery in severe comorbid patients with irreparable extensor mechanism disruption, severe instability, and extensive soft tissue loss. Knee arthrodesis using a dual-plate construct has been scarcely reported. We report a case of knee arthrodesis using a dual-plate construct in a male in his 20s who presented to us with a broken distal femur megaprosthesis. Case Report: An anterior midline incision was given. The cement mantle and broken prosthetic components were removed. The bone surfaces were freshened up and fixed using two orthogonal locking plates. After 4 months, there was a solid fusion in the knee, and the patient started walking independently with a short limb gait. The patient was advised limb lengthening for a shortening of 3 cm, but he denied it and managed with a shoe raise. After 4 years, he was pain free, and radiographs revealed a solid knee fusion. The patient was fully satisfied with the procedure, and he resumed manual work. Conclusion: This case report revealed that knee arthrodesis using a dual-plate construct is an economically viable salvage option for failed distal femur megaprosthesis.

13.
Injury ; 55(2): 111272, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38134491

RESUMO

INTRODUCTION: Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of an effective, readily available medial implant option. METHODS: A retrospective analysis from January 2014 to August 2023 was performed on DFF requiring revision open reduction internal fixation (rORIF) with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5 mm cortical, 5 mm locking and/or 6.5 mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. The primary outcome was union rate. RESULTS: This technique was utilised on fifteen patients. The mean age was 55±15 (range 23-81); 73 % of cases were male and the median follow-up was 61 weeks (IQR 49-87). The two most common fracture patterns were AO/OTA 33-C3 (n = 5) and 33-A3 (n = 4), and three patients had open fractures. The union rate was 93 % (14/15), with a median time to union of 29 weeks (IQR 18-49). There were two complications: a deep infection requiring two debridements and locally eluding antibiotic insertion, and a prominent screw requiring removal; both patients achieved union. The median range of motion was 0° (IQR 0-5) of extension and 100° (IQR 90-120) of flexion. CONCLUSION: Supplemental medial plating of DFF with a Large Fragment LCP T-Plate is a feasible, safe, and economical option for rORIF. Further validation on a larger scale is warranted, along with considerations to developing a specific implant in line with these principles.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Fraturas Expostas , Humanos , Masculino , Idoso , Adulto , Pessoa de Meia-Idade , Feminino , Fraturas do Fêmur/cirurgia , Reoperação , Estudos Retrospectivos , Fraturas Expostas/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas , Resultado do Tratamento
14.
J Orthop Case Rep ; 14(10): 90-95, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39381298

RESUMO

Introduction: The incidence of ipsilateral neck of femur fracture with the shaft of femur going for non-union is not known. Management of this concomitant non-union can be a daunting task in terms of fixation strategy and its outcome. Case Report: In this article, we report a case of a 25-year-old male with ipsilateral neck of femur with shaft non-union. We have done open reduction and dual plating with bone grafting for the shaft of the femur followed by valgus subtrochanteric osteotomy with dynamic hip screw and impaction bone grafting for the neck of femur non-union. Conclusion: The main principle in treating the neck of femur non-union is biomechanical correction of shear forces into compression forces by valgus correction and impaction bone grafting aids fracture healing. Dual plating with bone grafting gives optimal results in shaft non-union.

15.
Shoulder Elbow ; 15(6): 641-646, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37981973

RESUMO

Introduction: Recent interest has been directed towards dual plate fixation for comminuted proximal humerus fractures, with an aim to improve construct stability and thus improve patient outcomes while decreasing the risk of fracture-associated complications. We present our experience with this technique in a case series of patients with proximal humerus fractures and describe our surgical technique. Methodology: This was a single-center retrospective case series of patients presenting with an acute (<6 weeks) proximal humerus fracture who underwent ORIF with dual plating fixation. Patient, fracture, and surgical data were collected. All patient outcomes were evaluated using Constant-Murley shoulder score and Single Assessment Numeric Evaluation. Results: Our series included nine patients with a mean age of 46.2 years (range: 27-70 years old). All fractures healed within 4 months and no complications were encountered. At 1 year follow-up, the mean SANE score was 69.4% and the mean Constant Murley shoulder score was 78.9 (range: 70-96). Conclusion: Our current series shows that applying the dual plating technique in severely comminuted proximal humerus fractures provides adequate fixation and thus good patient outcomes. Further research is required before this technique can be strongly recommended for management of these complex fractures. Level of Evidence: Level 5.

16.
Am J Sports Med ; 51(13): 3393-3400, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37849249

RESUMO

BACKGROUND: Recent studies have highlighted dual plating as a method of reducing high rates of postoperative complication after operative management of displaced midshaft clavicular fractures. However, few studies have reliably characterized reoperation rates and magnitude of risk reduction achieved when using dual versus anterior and superior single-plate techniques. HYPOTHESIS: There would be lower rates of reoperation among patients who underwent open reduction and internal fixation (ORIF) of displaced midshaft clavicular fractures via dual plating. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This was a retrospective analysis of patients who underwent ORIF for a displaced midshaft clavicular fracture between 2010 and 2021 at a level 1 trauma center with a minimum 12-month follow-up. Patients were separated into 3 cohorts based on fixation type: (1) orthogonal dual mini-fragment plate fixation, (2) superior plate fixation, and (3) anterior plate fixation. Data on patient characteristics, fracture pattern, and reoperations were documented. All-cause reoperation rates and hazard ratio (HR) estimates of dual, superior, and anterior plating were calculated using a multivariate multilevel mixed-effects parametric survival model. Significant confounders including high-risk fracture morphology and smoking status were controlled for in the final model. RESULTS: A final cohort of 256 patients was identified with mean follow-up of 4.9 ± 3.8 years. In total, 101 patients underwent superior plating, 92 underwent anterior plating, and 63 underwent dual plating. Overall, 31 reoperations took place (18 in superior, 12 in anterior, 1 in dual plating) among 22 patients. Major contributors to reoperation included symptomatic hardware (n = 11), nonunion (n = 8), deep infection (n = 7), and wound dehiscence (n = 2). Superior plating revealed the highest reoperation rate of 0.031 per person-years, followed by anterior plating with 0.026 per person-years and dual plating with 0.005 per person-years. Overall, single plating (either anterior or superior placement) had a nearly 8-fold greater risk of reoperation than dual plating (HR, 7.62; 95% CI, 1.02-56.82; P = .048). Further broken down by technique, superior plating had an 8-fold greater risk of reoperation than dual plating (HR, 8.36; 95% CI, 1.10-63.86; P = .041), but anterior plating did not demonstrate a statistically significant difference compared with dual plating (HR, 6.79; 95% CI, 0.87-52.90; P = .068). CONCLUSION: Dual-plate fixation represents an excellent treatment for displaced midshaft clavicular fractures, with low rates of nonunion and reoperation. When compared with single locked superior or anterior plate fixation, dual mini-fragment plate fixation has a nearly 8-fold lower risk of reoperation.


Assuntos
Clavícula , Fraturas Ósseas , Humanos , Reoperação/efeitos adversos , Estudos de Coortes , Estudos Retrospectivos , Clavícula/cirurgia , Clavícula/lesões , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Complicações Pós-Operatórias/etiologia , Placas Ósseas/efeitos adversos , Resultado do Tratamento
17.
J Clin Med ; 12(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36675625

RESUMO

Double plating for proximal humeral fractures (PHF) is an option to increase the primary fixation stability. Clinical data is missing for assessment of clinical and radiological outcome, as well as complications. We retrospectively examined 35 patients with unilateral PHF, who were treated with double plating for PHF between 2013 and 2019. The mean age was 59.5 ± 12 years and the leading fracture type was a varus dislocation (Resch type IV in 55.3%). A head-split was present in 22.9% of the cases. The primary outcome measurement was the radiological neck shaft angle (NSA). The radiological follow-up was 21 ± 16.6 months and the NSA did not differ between the intraoperative and follow-up time point (131.5 ± 6.9° vs. 136.6 ± 13.7°; p = 0.267). The clinical follow-up was 29.5 ± 15.3 months. The Constant-score was 78.5 ± 17 points, the simple-shoulder-test (SST) was 9.3 ± 3.2 points and the subjective shoulder value (SSV) was 78.8 ± 19.5%. The over-all complication rate was 31.4%, and without stiffness 14.3%. An avascular necrosis occurred in two patients (5.7%). In conclusion, this study shows good radiological and functional outcomes after double plating of highly complex proximal humeral fractures, while the complication rate is comparable to the literature. Double plating is a viable option especially for younger patients with complex fractures as a potential alternative to fracture arthroplasty.

18.
Trauma Case Rep ; 43: 100768, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36686415

RESUMO

Complex femur fractures are defined as combined fractures of shaft and proximal or the distal femur. It usually occurs in young adults due to high energy trauma. Treatment of this type of fracture is challenging. Herein, we present the management of multi-level complex femoral fracture in 38 years old using minimally invasive overlapping dual plating with bridge proximal femoral locking plate from above and distal femoral locking plate from below. Favourable clinical and radiologic outcomes were observed. The result demonstrates dual plating of complex femoral fracture using MIPO could be considered as a suitable treatment option for complex femoral fracture.

19.
OTA Int ; 6(1): e227, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36760659

RESUMO

Introduction: Lateral locked plating (LLP) development has improved outcomes for distal femur fractures. However, there is still a modest rate of nonunion in fractures treated with LLP alone, with higher nonunion risk in high-energy fractures, intra-articular involvement, poor bone quality, severe comminution, or bone loss. Several recent studies have demonstrated both the safety and the biomechanical advantage of dual medial and lateral plating (DP). The purpose of this study was to evaluate the clinical outcomes of DP for native distal femoral fractures by performing a systematic review of the literature. Methods: Studies reporting clinical outcomes for DP of native distal femur fractures were identified and systematically reviewed. Publications without full-text manuscripts, those solely involving periprosthetic fractures, or fractures other than distal femur fractures were excluded. Fracture type, mean follow-up, open versus closed fracture, number of bone grafting procedures, nonunion, reoperation rates, and complication data were collected. Methodologic study quality was assessed using the Coleman methodology score. Results: The initial electronic review and reverse inclusion protocol identified 1484 publications. After removal of duplicates and abstract review to exclude studies that did not discuss clinical treatment of femur fractures with dual plating, 101 potential manuscripts were identified and manually reviewed. After final review, 12 studies were included in this study. There were 199 fractures with average follow-up time of 13.72 months. Unplanned reoperations and nonunion occurred in 19 (8.5%) and 9 (4.5%) cases, respectively. The most frequently reported complications were superficial infection (n = 6, 3%) and deep infection (n = 5, 2.5%) postoperatively. Other complications included delayed union (n = 6, 3%) not requiring additional surgical treatment and knee stiffness in four patients (2%) necessitating manipulation under anesthesia or lysis of adhesions. The average Coleman score was 50.5 (range 13.5-72), suggesting that included studies were of moderate-to-poor quality. Conclusions: Clinical research interest in DP of distal femoral fractures has markedly increased in the past few decades. The current data suggest that DP of native distal femoral fractures is associated with favorable nonunion and reoperation rates compared with previously published rates associated with LLP alone. In the current review, DP of distal femoral fractures was associated with acceptable rates of complications and generally good functional outcomes. More high-quality, directly comparable research is necessary to validate the conclusions of this review.

20.
Artigo em Inglês | MEDLINE | ID: mdl-37453125

RESUMO

Introduction: Posterior tibial plateau fractures are a rare type of fractures. Most surgeons are accustomed to operate in the supine position, however, surgery in the posterior knee region and operating in prone position can be challenging because of the presence of neurovascular structures including the tibial nerve, popliteal artery and vein, common peroneal nerve and, also challenging to achieve effective reduction and fixation, thus, it is less commonly performed. Materials and methods: Between February and September 2022 four posterior tibial plateau fractures were diagnosed and operated in our clinic within a six months follow-up (2 female and 2 male with mean age of 48.5 years). All were diagnosed with X-rays and CT scans. All of the fractures were on the right leg. Posterior "S shape" approach in prone position was used to reduce the tibial condyle and fix it with a plate. In fracture patterns that include lateral plateau impressions, the posterior "S shape" approach may not be sufficient to perform open reduction and internal fixation of the lateral condyle, so an additional anterolateral approach was made and additional locking plate was placed. Radiographic evaluation included reduction quality and satisfactory alignment of the bone axis. Results: All fractures healed within 6 months, without secondary displacement. Throughout the follow-up period, there were no incidences of post-traumatic osteoarthritis of the knee. No patient complained of knee instability. Conclusion: The direct dorsal approach allowed for adequate open reduction and internal fixation, and early clinical results are promising. However, in fracture patterns that include lateral plateau impressions, the posterior "S shape" approach may not be sufficient to perform open reduction and internal fixation of the lateral condyle, so an additional anterolateral approach should be made and additional locking plate to be placed.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Radiografia , Tomografia Computadorizada por Raios X , Fixação Interna de Fraturas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA