RESUMO
PURPOSE: The clinical significance of negative toxin enzyme immunoassays (EIA) for Clostridioides difficile infections (CDIs) is unclear. Our study aimed to investigate the significance of toxin EIA-negative in the diagnosis and prognosis of CDI. METHODS: All stool specimens submitted for C. difficile toxin EIA testing were cultured to isolate C. difficile. In-house PCR for tcdA, tcdB, cdtA, and cdtB genes were performed using C. difficile isolates. Stool specimens were tested with C. difficile toxins A and B using EIA kit (RIDASCREEN Clostridium difficile toxin A/B, R-Biopharm AG, Darmstadt, Germany). Characteristics and subsequent CDI episodes of toxin EIA-negative and -positive patients were compared. RESULTS: Among 190 C. difficile PCR-positive patients, 83 (43.7%) were toxin EIA-negative. Multivariate analysis revealed independent associations toxin EIA-negative results and shorter hospital stays (OR = 0.98, 95% CI 0.96-0.99, p = 0.013) and less high-risk antibiotic exposure in the preceding month (OR = 0.38, 95% CI 0.16-0.94, p = 0.035). Toxin EIA-negative patients displayed a significantly lower white blood cell count rate (11.0 vs. 35.4%, p < 0.001). Among the 54 patients who were toxin EIA-negative and did not receive CDI treatment, three (5.6%) were diagnosed with CDI after 7-21 days without complication. CONCLUSION: Our study demonstrates that toxin EIA-negative patients had milder laboratory findings and no complications, despite not receiving treatment. Prolonged hospitalisation and exposure to high-risk antibiotics could potentially serve as markers for the development of toxin EIA-positive CDI.
Assuntos
Proteínas de Bactérias , Toxinas Bacterianas , Clostridioides difficile , Infecções por Clostridium , Fezes , Humanos , Clostridioides difficile/genética , Fezes/microbiologia , Masculino , Feminino , Toxinas Bacterianas/análise , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/tratamento farmacológico , Infecções por Clostridium/microbiologia , Idoso , Pessoa de Meia-Idade , Proteínas de Bactérias/genética , Proteínas de Bactérias/análise , Enterotoxinas/análise , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Técnicas Imunoenzimáticas , Adulto , Resultado do Tratamento , Reação em Cadeia da Polimerase , PrognósticoRESUMO
The classification of a hydropower scheme as run-of-the-river (or run-of-river; ROR) evokes an image of a low-impact installation; however, examination of eight case studies worldwide shows that substantial negative societal and ecological impacts are tied to them, albeit in somewhat different ways. We conclude that ROR dams not only potentially displace communities, disrupt livelihoods, and degrade environments in surrounding areas, but they also divert water from areas of need, impact aquatic ecology through habitat destruction and disruption of fish migrations, emit non-trivial amounts of greenhouse gases over the lifespan of the project, and disrupt streamflow in downstream river sections. While these negative impacts vary on a case-by-case basis, medium and large ROR dams consistently have multiple and cumulative impacts, even when not having appreciable reservoirs. We contend that many impactful dams do not qualify as low-impact ROR projects, despite being defined as such. Such mislabeling is facilitated in part by the ambiguous definition of the term, which risks the ROR concept being used by proponents of impactful structures to downplay their negative effects and thus mislead the public or gain status, including within the Clean Development Mechanism in relation to mitigating climate change.
RESUMO
Environmental impact assessment (EIA) has become one of the most widespread environmental management instruments. Despite this, EIA is routinely criticized for being ineffective at impacting decision-making. This study compared the EIA systems of Paraná, Brazil and California, United States using the effectiveness dimensions from the EIA literature. This study formats the cases into contextual conditions using the fuzzy-set qualitative comparative analysis (fsQCA) to identify the necessary or sufficient conditions that cause effective outcomes. These effectiveness outcomes are then ranked by EIA stakeholders via the analytical hierarchy process (AHP) to identify stakeholder priorities and to improve stakeholder management. The results show that in Paraná stakeholders identified normative effectiveness as the most important dimension, while stakeholders in California identified this dimension as the second-most important following substantive effectiveness. Public participation was found to be a necessary condition for both substantive and normative effectiveness to occur. Early project definition was found to be sufficient for substantive effectiveness and necessary for normative effectiveness, for which stakeholder coordination was a sufficient condition. This suggests that in order for EIA to influence decision-making and foster sustainable development, greater care needs to be taken to actively engage stakeholders in public participation, with clear roles and project design communicated early on, and a clear role for regulatory authority to promote stakeholder coordination for acceptable outcomes. These findings suggest that some effectiveness dimensions are caused by similar conditions, which could help focus stakeholder management efforts and point to new avenues for future EIA effectiveness research.
Assuntos
Processo de Hierarquia Analítica , Meio Ambiente , Estados Unidos , Humanos , Brasil , Desenvolvimento Sustentável , CaliforniaRESUMO
BACKGROUND: As countries move towards or achieve measles elimination status, serosurveillance is an important public health tool. However, a major challenge of serosurveillance is finding a feasible, accurate, cost-effective, and high throughput assay to measure measles antibodyâ¯concentrationsâ¯and estimate susceptibility in a population. We conducted a systematic review to assess, characterize, and - to the extent possible - quantify the performance of measles IgG enzyme-linked assays (EIAs) compared to the gold standard, plaque reduction neutralization tests (PRNT). METHODS: We followed the PRISMA statement for a systematic literature search and methods for conducting and reporting systematic reviews and meta-analyses recommended by the Cochrane Screening and Diagnostic Tests Methods Group. We identified studies through PubMed and Embase electronic databases and included serologic studies detecting measles virus IgG antibodies among participants of any age from the same source population that reported an index (any EIA or multiple bead-based assays, MBA) and reference test (PRNT) using sera, whole blood, or plasma. Measures of diagnostic accuracy with 95% confidence intervals (CI) were abstracted for each study result, where reported. RESULTS: We identified 550 unique publications and identified 36 eligible studies for analysis. We classified studies as high, medium, or low quality; results from high quality studies are reported. Because most high quality studies used the Siemens Enzygnost EIA kit, we generate individual and pooled diagnostic accuracy estimates for this assay separately. Median sensitivity of the Enzygnost EIA was 92.1% [IQR = 82.3, 95.7]; median specificity was 96.9 [93.0, 100.0]. Pooled sensitivity and specificity from studies using the Enzygnost kit were 91.6 (95%CI: 80.7,96.6) and 96.0 (95%CI: 90.9,98.3), respectively. The sensitivity of all other EIA kits across high quality studies ranged from 0% to 98.9% with median (IQR) = 90.6 [86.6, 95.2]; specificity ranged from 58.8% to 100.0% with median (IQR) = 100.0 [88.7, 100.0]. CONCLUSIONS: Evidence on the diagnostic accuracy of currently available measles IgG EIAs is variable, insufficient, and may not be fit for purpose for serosurveillance goals. Additional studies evaluating the diagnostic accuracy of measles EIAs, including MBAs, should be conducted among diverse populations and settings (e.g., vaccination status, elimination/endemic status, age groups).
Assuntos
Sarampo , Humanos , Testes de Neutralização/métodos , Técnicas Imunoenzimáticas , Vírus do Sarampo , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina GRESUMO
The pygmy hippopotamus (Choeropsis liberiensis) is an endangered species endemic to the Upper Guinea Forest ecosystem in West Africa. We have limited information concerning the species' reproduction and well-being under managed care. We therefore developed non-invasive methods for characterizing gonadal androgen and adrenal hormone profiles in pygmy hippos using fecal samples collected from 12 males and 12 females housed in North American zoological institutions. We aimed to: 1) identify and validate enzyme immunoassays (EIAs) for measuring metabolites of corticosteroids and testosterone in feces; and 2) test whether gonadal activity is correlated with previous breeding history, season or type of housing. For glucocorticoids, several EIAs for measuring metabolites were investigated. A group-specific EIA exhibiting cross-reactivity with 11,17-dioxoandrostane (DOA) metabolites of cortisol most clearly reflected adrenocortical activity in response to pharmocological challenge with adrenocorticotropic hormone (ACTH) in both males and females. However, day-to-day concentrations of this metabolite in the feces of pygmy hippos that did not undergo ACTH challenge were near the detection limits of the assay, making this EIA impractical for assessing glucocorticoid activity in this species. Another group-specific EIA, exhibiting cross-reactivity with 5α-pregnane-3ß,11ß,21-triol-20-one, produced biologically relevant data and evidence of an appropriate response to pharmacological challenge with exogenous ACTH. The testosterone metabolite assay C196 (Arbor Assays, Ann Arbor, Michigan, USA) also produced biologically coherent data: adult males exhibited the highest mean androgen metabolite concentrations (477 ng/g), followed by adult females (259 ng/g) and juvenile males (160 ng/g). Proven breeding males had higher, but not significantly different, mean concentrations (472 ng/g) to unproven males (352 ng/g; P = 0.400). Similarly, adult males housed outdoors year-round in subtropical climates exhibited higher, but not statistically different mean concentrations (554 ng/g) to males in temperate climates that were housed indoors at least part of the year (412 ng/g; P = 0.208). There were, however, significant differences in mean concentrations among seasons for adult males, with higher values in spring (546 ng/g) and summer (542 ng/g) than in autumn (426 ng/g) and winter (388 ng/g, P = 0.003). In conclusion, we identified EIAs for the measurement of fecal metabolites of androgens and glucocorticoids that can be used for further studies to monitor gonadal activity in male pygmy hippos and adrenocortical activity in both sexes. We also identified a seasonal trend in male gonadal activity in this species under managed care in North America. Finally, our findings highlight an important consideration when using non-invasive methods for evaluating fecal cortisol metabolites: ACTH used for pharmacological validation of an EIA does not necessarily equate to biological relevance.
Assuntos
Artiodáctilos , Glucocorticoides , Feminino , Animais , Masculino , Glucocorticoides/metabolismo , Androgênios , Hidrocortisona/metabolismo , Ecossistema , Testosterona , Hormônio Adrenocorticotrópico/farmacologia , Fezes , Técnicas ImunoenzimáticasRESUMO
BACKGROUND: Diagnosis of Clostridioides difficile Infection (CDI) entails compatible clinical presentation and laboratory findings. We evaluated real-time polymerase chain reaction (qPCR) cycle threshold (CT) as a predictor for disease severity and TcdB enzyme immunoassay (EIA) results. METHODS: Inpatients or emergency department patients who tested positive for tcdB gene by PCR were evaluated. Patients' stools underwent testing for GDH and TcdA/B by EIA. Medical health records were reviewed for demographic, clinical presentation, laboratory, treatment and outcome data. Severity of CDI was calculated using various severity score indexes. RESULTS: The median CT of cases was 32.05 ± 5.45. The optimal cut-off for predicting toxin EIA positivity and severe CDI based on chart review was 32.6 and 29.8, respectively, with the area under the receiver operator characteristics curve (AUC) of 0.74 and 0.60 respectively. CONCLUSION: CT value was an acceptable predictor for EIA toxin but less so for clinical severity. Our study potentially supports a diagnostic algorithm including CT value to reduce the number of EIA toxin assays performed.
Assuntos
Toxinas Bacterianas , Clostridioides difficile , Infecções por Clostridium , Humanos , Toxinas Bacterianas/genética , Toxinas Bacterianas/análise , Clostridioides difficile/genética , Clostridioides/genética , Técnicas Imunoenzimáticas , Infecções por Clostridium/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Fezes/química , Proteínas de Bactérias/genética , Proteínas de Bactérias/análiseRESUMO
Early diagnosis of invasive aspergillosis is an important factor to improve survival but remains challenging. The detection of Aspergillus antigens is included in the consensus case definitions of the European Organization for Research and Treatment of Cancer and the National Institute of Allergy and Infectious Diseases Mycoses Study Group as a criterion of "probable" invasive aspergillosis. JF5, a mouse IgG3 monoclonal antibody detecting an Aspergillus mannoprotein, has already been implemented as a lateral flow device (LFD). Now, also a JF5-based enzyme-linked immunosorbent assay (EIA) is commercialized (Aspergillus specific galactomannoprotein [GP] EIA, Euroimmun Medizinische Labordiagnostika AG). In this study, we analyzed the diagnostic performance of GP in 63 bronchoalveolar lavage fluid (BALf) samples and 224 serum samples and compared it to performance of the galactomannan (GM) (Platelia Aspergillus enzyme immunoassay (EIA) (Bio-Rad, Marnes-la-Coquette, France)) and the JF5-based LFD (AspLFD; OLM Diagnostics, Newcastle Upon Tyne, United Kingdom). The diagnostic performance of GP and GM correlated well with both having high specificity. With an optimized cutoff threshold for positivity of 0.4-deviating from the 0.5 threshold recommended by the manufacturer-sensitivity of GP in serum is not significantly different than that of GM. However, in BALf sensitivity of GP is significantly less than for GM.
Assuntos
Aspergilose , Infecções Fúngicas Invasivas , Aspergilose Pulmonar Invasiva , Animais , Camundongos , Líquido da Lavagem Broncoalveolar , Aspergilose Pulmonar Invasiva/diagnóstico , Sensibilidade e Especificidade , Mananas , Antígenos de Fungos , Aspergillus , Aspergilose/diagnóstico , Ensaio de Imunoadsorção EnzimáticaRESUMO
Rubella and congenital rubella syndrome are caused by the rubella virus and are preventable through vaccination, making disease eradication possible. Monitoring of progress toward global eradication and local elimination requires high-quality, sensitive disease surveillance that includes laboratory confirmation of cases. Previous evaluations of anti-rubella IgM detection methods resulted in the broad adoption of the Enzygnost (most recently manufactured by Siemens) enzyme-linked immunosorbent assay (ELISA) kits within WHO's global measles and rubella laboratory network, but they have been discontinued. This study evaluated seven comparable ELISAs from six manufacturers (Trinity Biotech, Euroimmun, Clin-Tech, NovaTec and Virion\Serion) as well as one automated chemiluminescent assay (CLIA) from DiaSorin. These assays include three IgM capture assays and five indirect ELISAs. A panel of 238 sera was used for the evaluation that included 38 archival rubella IgM-positive sera and 200 sera collected from patients with symptomatically similar diseases, such as measles, dengue, parvovirus B19 infection, and roseola. With this panel of sera, the sensitivity of the methods ranged from 63.2% to 100% and the specificity from 80.0% to 99.5%. No single method had both sensitivity and specificity of >90%, unless sera with equivocal results were considered presumptively positive. Some assays, particularly the Serion ELISA, had a large number of false positives with parvovirus B19 IgM-positive sera as well as sera from confirmed measles cases. The performance characteristics identified in this evaluation serve as a reminder to not rely solely on rubella IgM results for case confirmation in elimination settings.
Assuntos
Sarampo , Rubéola (Sarampo Alemão) , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina M , Sarampo/diagnóstico , Rubéola (Sarampo Alemão)/diagnóstico , Vírus da Rubéola , Sensibilidade e EspecificidadeRESUMO
OBJECTIVES: Updated guidelines for patients with axial SpA (axSpA) have sought to reduce diagnostic delay by raising awareness among clinicians. We used the National Early Inflammatory Arthritis Audit (NEIAA) to describe baseline characteristics and time to diagnosis for newly referred patients with axSpA in England and Wales. METHODS: Analyses were performed on sociodemographic and clinical metrics, including time to referral and assessment, for axSpA patients (n = 784) recruited to the NEIAA between May 2018 and March 2020. Comparators were patients recruited to the NEIAA with RA (n = 9270) or mechanical back pain (MBP; n = 370) in the same period. RESULTS: Symptom duration prior to initial rheumatology assessment was longer in axSpA than RA patients (P < 0.001) and non-significantly longer in axSpA than MBP patients (P = 0.062): 79.7% of axSpA patients had symptom durations of >6 months, compared with 33.7% of RA patients and 76.0% of MBP patients. Following referral, the median time to initial rheumatology assessment was longer for axSpA than RA patients (36 vs 24 days; P < 0.001) and similar to MBP patients (39 days; P = 0.30). Of the subset of patients deemed eligible for early inflammatory arthritis pathway follow-up, fewer axSpA than RA patients had disease education provided (77.5% vs 97.8%) and RA patients reported a better understanding of their condition and treatment. CONCLUSION: Diagnostic delay in axSpA remains a major challenge despite improved disease understanding and updated referral guidelines. Disease education is provided to fewer axSpA than RA patients, highlighting the need for specialist clinics and support programmes for axSpA patients.
Assuntos
Espondiloartrite Axial/diagnóstico , Adulto , Idoso , Artrite Reumatoide/diagnóstico , Dor nas Costas/diagnóstico , Diagnóstico Tardio , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Encaminhamento e Consulta/estatística & dados numéricos , Fatores de Tempo , Reino UnidoRESUMO
Infectious diarrhea is caused by a variety of pathogens, including viruses, bacteria, and parasitic organisms. Though the causative agent of diarrhea has historically been evaluated via stool cultures, recently, culture-independent diagnostic tests (CIDT) have been developed and utilized with increasing frequency. Current practice guidelines recommend their use as adjuncts to stool cultures for diagnosing acute and chronic diarrhea. The three principal CIDT are microscopy, enzyme-based immunoassays (EIAs), and molecular based polymerase chain reaction (PCR). This review explores the common causes of infectious diarrhea, the basics of stool culture, the diagnostic utility of these three culture-independent modalities, and the strengths and weaknesses of all currently available clinical techniques. It also outlines considerations for specific populations including returning travelers and those with inflammatory bowel disease.
Assuntos
Diarreia , Fezes/microbiologia , Técnicas Imunoenzimáticas/métodos , Técnicas Microbiológicas , Microscopia/métodos , Reação em Cadeia da Polimerase/métodos , Meios de Cultura , Diarreia/diagnóstico , Diarreia/microbiologia , Humanos , Técnicas Microbiológicas/métodosRESUMO
Environmental Impact Assessment (EIA) emerged as a regulatory procedure and is now implemented worldwide. EIA aims to increase the sustainability of economic activities by decreasing the impact on environmental components. Transparency of the evaluation process is a key feature of the procedure, and this is achieved predominantly by encouraging participation in public debates. Public participation is essential for EIA's effectiveness, particularly in transboundary projects. This study evaluates whether media coverage of certain projects with transboundary environmental impacts increases public participation during EIA. We analyzed how online media covered the stories about four major projects subject to the EIA procedure in Romania (i.e., reactors 3 and 4 of Cernavoda Nuclear Power Plant, Oltenita used oil recycling facility, Certej mining project, management of Moldova Noua tailing ponds). We focused on articles published between 2010 and 2020, covering stories about the four projects. We further extracted the stakeholders involved in the projects using social network analysis. We extracted the main topics of articles discussing the four projects using deep categorization tools. The polarities of titles and contents of the articles were assessed using sentiment analysis tools. Our findings indicate that EIA is a media subject only when NGOs become important actors in the process and the industry generated local industrial disasters in the past; otherwise, the media rarely debate the environmental impact of projects. Without NGO reactions, Romanian readers are fed with political and economic aspects driven by large projects rather than environmental issues. The outcome of the current study is significant for understanding what triggers NGOs and the media to take a stand against major projects. Projects involving activities that generated ecological disasters in Romania's recent history are strongly opposed by NGOs and the public. In such cases, environmental and EIA topics are more often included in media stories. However, projects with undeniable environmental impact but without a negative background in Romania do not reach the public agenda, and the media stories do not focus on environmental aspects either, leading to limited public participation within the EIA procedure.
Assuntos
Desastres , Meio Ambiente , Humanos , Indústrias , Participação da Comunidade , MineraçãoRESUMO
In South Africa, the relevant authorities use environmental impact assessments (EIAs) to achieve sustainable development. Biodiversity impact assessment (BIA) studies are part of EIAs to ensure that biodiversity issues are considered. In 2013, the mining industry published the Mining and biodiversity guideline to improve the integration of biodiversity into their activities. This research analysed the inclusion of biodiversity impacts in mining EIAs before and after the publication of the guideline. A customised mining BIA report-review package was developed and used to review 46 mining BIAs produced before and after 2013. Secondary data were collected using questionnaires on the inclusion of biodiversity impacts in mining EIAs. The results showed that most BIAs failed to properly consider biodiversity issues, with an overall satisfactory score of 43% before and 57% after 2013. Areas of weakness included project description, sensitivity mapping, stakeholder consultation, consideration of alternatives, and monitoring. The extent to which biodiversity specialist inputs were included in the main mining EIA reports showed an improvement after 2013, with an overall satisfactory score of 78%, compared to the 52% before 2013. The majority of the BIAs complied with the minimum requirements for specialist studies stipulated by the National Environmental Management Act 107 of 1998 (NEMA). The analysis of the questionnaires revealed inadequacies regarding the inclusion of biodiversity impacts. These included poor consideration of indirect and cumulative impacts, failure to incorporate environmental thresholds, and use of the ecosystem approach.
Assuntos
Ecossistema , Monitoramento Ambiental , Biodiversidade , Monitoramento Ambiental/métodos , Mineração , África do SulRESUMO
BACKGROUND: Coccidioidomycosis (CM) is a common cause of community-acquired pneumonia where CM is endemic. Manifestations include self-limited pulmonary infection, chronic fibrocavitary pulmonary disease, and disseminated coccidioidomycosis. Most infections are identified by serological assays including enzyme-linked immunoassay (EIA), complement fixation, and immunodiffusion. These are time-consuming and take days to result, impeding early diagnosis. A new lateral flow assay (LFA; Sona; IMMY, Norman, OK) improves time-to-result to 1 hour. METHODS: We prospectively enrolled 392 patients with suspected CM, compared the LFA with standard EIA and included procalcitonin evaluation. RESULTS: Compared with standard EIA, LFA demonstrates 31% sensitivity (95% confidence interval [CI], 20-44%) and 92% specificity (95% CI, 88-95%). Acute pulmonary disease (74%) was the most common clinical syndrome. Hospitalized patients constituted 75% of subjects, and compared with outpatients, they more frequently had ≥3 previous healthcare facility visits (Pâ =â .05), received antibacterials (Pâ <â .01), and had >3 antibacterial courses (Pâ <â .01). Procalcitonin (PCT) was <0.25 ng/mL in 52 (83%) EIA-positive patients, suggesting infection was not bacterial. CONCLUSIONS: When CM is a possible diagnosis, LFA identified nearly one-third of EIA-positive infections. Combined with PCT <0.25 ng/mL, LFA could reduce unnecessary antibacterial use by 77%.
Assuntos
Coccidioidomicose , Coccidioidomicose/diagnóstico , Diagnóstico Precoce , Humanos , Imunoensaio , Técnicas Imunoenzimáticas , Sensibilidade e EspecificidadeRESUMO
The World Health Organization (WHO) has targeted measles for global eradication through mass immunization. For effective monitoring of eradication targets, high-quality surveillance is needed. The detection of IgM antibodies, specific to the measles virus, with the use of commercial enzyme-linked immunosorbent assays (ELISA or EIA) is broadly used within the WHO global measles and rubella laboratory network for laboratory confirmation, and in particular, ELISA kits manufactured by Siemens (Enzygnost kits) have been primarily used. Spurred by the discontinuation of these kits, this study aims to report on the clinical sensitivity and specificity of comparable commercial ELISA kits and one automated chemiluminescent immunoassay (CLIA) method. A panel of 239 serum samples was assembled that included sera from confirmed measles cases (n = 50) and probable post-MMR vaccine response (n = 2). Measles-negative sera (n = 187) were collected from individuals presenting with other fever and rash illnesses. A total of 7 ELISA kits (Euroimmun native antigens and recombinant nucleoprotein, IBL, Clin-Tech Microimmune, NovaTec NovaLisa, Serion, and Siemens Enzygnost) and one CLIA method (DiaSorin LIAISON XL) were evaluated. The ELISA kits included two IgM capture methods and five indirect methods. Calculated sensitivities and specificities ranged from 75.0% to 98.1% and 86.6% to 99.5%, respectively. The parvovirus B19 IgM positive sera were noted to cause false-positive results, particularly for the ELISA kits from Serion and NovaLisa; specificities for this subset of samples ranged from 51.4% to 100.0%. The capture IgM ELISA methods provided the best combination of sensitivity and specificity.
Assuntos
Anticorpos Antivirais , Sarampo , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina M , Sarampo/diagnóstico , Vírus do Sarampo , Sensibilidade e EspecificidadeRESUMO
Bartonella spp., mostly Bartonella quintana and B. henselae, are a common cause of culture-negative endocarditis. Serology using immunofluorescence assay (IFA) and PCR performed on cardiac tissues are the mainstays of diagnosis. We developed an enzyme immunoassay (EIA) and a novel multiplex real-time PCR assay, utilizing Bartonella genus-specific, B. henselae-specific, and B. quintana-specific SimpleProbe probes, for diagnosis of Bartonella endocarditis. We aimed to evaluate the performance of these assays. Thirty-seven patients with definite endocarditis, 18 with B. henselae, 18 with B. quintana, and 1 with B. koehlerae, were studied. Diagnosis was confirmed by conventional PCR and DNA sequencing of surgical cardiac specimens. Similar to the case with IFA, anti-Bartonella IgG titers of ≥1:800 were found in 94% of patients by EIA; cross-reactivity between B. henselae and B. quintana precluded species-specific serodiagnosis, and frequent (41%) but low-titer cross-reactivity between Coxiella burnetii antibodies and B. henselae antigen was found in patients with Q fever endocarditis. Low-titer (1:100) cross-reactivity was uncommonly found also in patients with brucellosis and culture-positive endocarditis, particularly Enterococcus faecalis endocarditis. Real-time PCR performed on explanted heart valves/vegetations was in complete agreement with results of sequence-based diagnosis with characteristic melting curves. The genus-specific probe identified five additional endocarditis-associated Bartonella spp. at the genus level. In conclusion, EIA coupled with a novel real-time PCR assay can play an important role in Bartonella endocarditis diagnosis and expand the diagnostic arsenal at the disposal of the clinical microbiologist. Since serology remains a major diagnostic tool, recognizing its pitfalls is essential to avoid incorrect diagnosis.
Assuntos
Infecções por Bartonella , Bartonella henselae , Bartonella quintana , Bartonella , Endocardite , Anticorpos Antibacterianos , Bartonella/genética , Infecções por Bartonella/diagnóstico , Bartonella henselae/genética , Bartonella quintana/genética , Humanos , Técnicas Imunoenzimáticas , Reação em Cadeia da Polimerase em Tempo Real , Testes SorológicosRESUMO
BACKGROUND: Malaria is a mosquito-borne infectious disease caused by protozoan parasites of the genus Plasmodium. As migration of populations from endemic areas to Europe and overseas recreational travel to endemic regions increase, there is also a growing risk of transfusion-transmitted tropical diseases by blood components. MATERIAL AND METHODS: In the present study two routine Plasmodium spp. ELISA (CAPTIA™ Malaria EIA, Trinity Biotech, and Malaria EIA, BioRad) were compared with a new commercial ELISA (ELISA IgG, EUROIMMUN). From December 1, 2015 until November 30, 2016, 1,096 plasma samples from blood donors with a potential risk of malaria infection were collected at two blood transfusion centres in Germany and Switzerland. RESULTS: The samples were tested comparatively with the ELISA from EUROIMMUN and the routine test used at the respective centre. Thirty-four of 595 (5.7%) tested blood samples from centre 1 and 49 of 501 (9.8%) tested blood samples from centre 2 showed reactivity on either or both ELISAs. All 83 reactive samples were sent for confirmation to the Diagnostic Centre of the Swiss Tropical and Public Health Institute (Swiss TPH) in Basel, Switzerland. Sixteen samples, which previously were reactive in the routine Plasmodium spp. EIA assays, were proven positive after confirmation testing (i.e., 4 positive and 12 inconclusive results), indicating an anti-Plasmodium antibody prevalence in blood donations of 1.5%. From these 16 reactive samples, 13 were also detected by the index test, resulting in an assay sensitivity of 81.2%. A specificity of 98.6% was calculated (1,065/1,080 confirmed negative samples). The overall agreement with the reference centre was 95.8% in centre 1 and 94% in centre 2. CONCLUSION: The comparison of the new EUROIMMUN ELISA and the established CAPTIA™ Malaria EIA (Trinity Biotech) and Malaria EIA (BioRad) used for routine blood donor screening in two laboratory blood donation centres revealed that all tested ELISAs show comparable sensitivities and are equally suitable for anti-Plasmodium antibody screening in blood banks.
RESUMO
OBJECTIVE: To assess the significance of serum vascular endothelial growth factor-A (VEGF-A) as a potential biomarker for the diagnosis of ovarian cancer instead of cancer antigen-125 (CA-125). METHODS: The case-control study was conducted at the obstetrics departments of Sir Ganga Ram Hospital and Jinnah Hospital, Lahore, Pakistan, from April to September 2018, and comprised cases of epithelial ovarian tumour and healthy female controls. Serum VEGF-A and CA-125 levels were evaluated using Luminex multi-analyte profiling technology and enzyme immunoassays technique. Age, stage, grading, metastasis and ascites of ovarian cancer patients were investigated and compared with serum VEGF-A and CA-125 levels. Data was analysed using SPSS 20. RESULTS: Of the 89 subjects, 44(49.4%) were cases and 45(49.6%) were controls. Among the cases, 13(29.5%) were benign and 31(70.5%) were malignant. The mean serum VEGF-A values were inversely proportional to the stages of ovarian cancer i.e. stage I, II, III and IV showed 762.2pg/ml, 267.3pg/ml, 233.1pg/ml and 125.5pg/ml VEGF-A levels respectively. A steady increase in the mean serum CA-125 values with the progression of the disease was observed i.e. in stage I, II, III and IV the levels of CA-125 were 146.2U/ml, 268.5U/ml and 477.2U/ml and 844.4U/ml respectively. CONCLUSIONS: The detection of high concentrations of serum VEGF-A level supported its use as one of the diagnostic parameters in the timely investigation of ovarian cancer.
Assuntos
Neoplasias Ovarianas , Fator A de Crescimento do Endotélio Vascular , Biomarcadores Tumorais , Antígeno Ca-125 , Estudos de Casos e Controles , Detecção Precoce de Câncer , Feminino , Humanos , Estadiamento de Neoplasias , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/patologiaRESUMO
The Singulex Clarity C. diff toxins A/B (Clarity) assay is an automated, ultrasensitive immunoassay for the detection of Clostridioides difficile toxins in stool. In this study, the performance of the Clarity assay was compared to that of a multistep algorithm using an enzyme immunoassay (EIA) for detection of glutamate dehydrogenase (GDH) and toxins A and B arbitrated by a semiquantitative cell cytotoxicity neutralization assay (CCNA). The performance of the assay was evaluated using 211 residual deidentified stool samples tested with a GDH-and-toxin EIA (C. Diff Quik Chek Complete; Techlab), with GDH-and-toxin discordant samples tested with CCNA. The stool samples were stored at -80°C before being tested with the Clarity assay. For samples discordant between Clarity and the standard-of-care algorithm, the samples were tested with PCR (Xpert C. difficile; Cepheid), and chart review was performed. The testing algorithm resulted in 34 GDH+/toxin+, 53 GDH-/toxin-, and 124 GDH+/toxin- samples, of which 39 were CCNA+ and 85 were CCNA- Clarity had 96.2% negative agreement with GDH-/toxin- samples, 100% positive agreement with GDH+/toxin+ samples, and 95.3% agreement with GDH+/toxin-/CCNA- samples. The Clarity result was invalid for one sample. Clarity agreed with 61.5% of GDH+/toxin-/CCNA+ samples, 90.0% of GDH+/toxin-/CCNA+ (high-positive) samples, and 31.6% of GDH+/toxin-/CCNA+ (low-positive) samples. The Singulex Clarity C. diff toxins A/B assay demonstrated high agreement with a testing algorithm utilizing a GDH-and-toxin EIA and CCNA. This novel automated assay may offer an accurate, stand-alone solution for C. difficile infection (CDI) diagnostics, and further prospective clinical studies are merited.
Assuntos
Proteínas de Bactérias/análise , Toxinas Bacterianas/análise , Clostridioides difficile/química , Clostridioides difficile/enzimologia , Enterotoxinas/análise , Glutamato Desidrogenase/análise , Técnicas Imunoenzimáticas/normas , Adulto , Algoritmos , Automação Laboratorial , Infecções por Clostridium/diagnóstico , Fezes/química , Feminino , Humanos , Masculino , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: Rapid detection of Shiga toxin-producing Escherichia coli (STEC) enables appropriate monitoring and treatment. We synthesized available evidence to compare the performance of enzyme immunoassay (EIA) and PCR tests for the detection of STEC. METHODS: We searched published and gray literature for studies of STEC EIA and/or PCR diagnostic test accuracy relative to reference standards including at least one nucleic acid amplification test. Two reviewers independently screened studies, extracted data, and assessed quality with the second version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Bivariate random effects models were used to meta-analyze the clinical sensitivity and specificity of commercial EIA and PCR STEC diagnostic tests, and summary receiver operator characteristic curves were constructed. We evaluated the certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. RESULTS: We identified 43 articles reflecting 25 260 specimens. Meta-analysis of EIA and PCR accuracy included 25 and 22 articles, respectively. STEC EIA pooled sensitivity and specificity were 0.681 (95% CI, 0.571-0.773; very low certainty of evidence) and 1.00 (95% CI, 0.998-1.00; moderate certainty of evidence), respectively. STEC PCR pooled sensitivity and specificity were 1.00 (95% CI, 0.904-1.00; low certainty of evidence) and 0.999 (95% CI, 0.997-0.999; low certainty of evidence), respectively. Certainty of evidence was downgraded because of high risk of bias. CONCLUSIONS: PCR tests to identify the presence of STEC are more sensitive than EIA tests, with no meaningful loss of specificity. However, given the low certainty of evidence, our results may overestimate the difference in performance.
Assuntos
Infecções por Escherichia coli/diagnóstico , Toxina Shiga/análise , Escherichia coli Shiga Toxigênica/patogenicidade , Testes Diagnósticos de Rotina/métodos , Escherichia coli/enzimologia , Escherichia coli/metabolismo , Proteínas de Escherichia coli/metabolismo , Técnicas Imunoenzimáticas/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Toxina Shiga/metabolismo , Escherichia coli Shiga Toxigênica/genética , Escherichia coli Shiga Toxigênica/metabolismoRESUMO
Nucleic acid testing (NAT) was implemented in Poland in 1999 for screening of plasma for fractionation and for all blood donors in 2002. To analyze seronegative NAT-positive samples representing hepatitis C virus (HCV) window-period (WP) in the years 2000 to 2016 and to determine infection outcome. We analyzed results of 17 502 739 donations screened in minipools (6-48) or individually. Index samples underwent viral load (VL) quantification, genotyping and Ag, and anti-HCV re-testing using chemiluminescence (CMIA), electrochemiluminescence (ECLIA), and fourth-generation enzyme-linked immunosorbent assay (IV EIA) assays. HCV-seronegative infections were identified in 126 donations (7.2/mln donations; 95% confidential intervals, 6.0-8.6). Frequency of NAT yields was decreasing over time. Of the initial 126 seronegative index cases 106 were retested: 32.1% were reactive in IV EIA, 11.3% in ECLIA, and 1.9% in CMIA. The lowest VL correlated with absent anti-HCV and HCV Ag, while VL was highest when the antigen was detectable and then it decreased when anti-HCV appeared at a level detectable by sensitive third generation tests while retesting. The proportion of genotype 1 was 38.9% in samples positive only for HCV RNA and 71.4% in samples that were anti-HCV reactive in re-testing. In parallel, genotype 3 frequency was 50% in the former group and 21% in the latter. NAT is an effective measure to limit HCV transmission by transfusion and IV EIA seems to have higher clinical sensitivity than ECLIA. Samples representing likely successive phases of early HCV infection were characterized by different genotype distribution probably due to very early elimination of genotype 3.