Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Bioinformatics ; 25(1): 227, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956454

RESUMO

BACKGROUND: Multivariate synchronization index (MSI) has been successfully applied for frequency detection in steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) systems. However, the standard MSI algorithm and its variants cannot simultaneously take full advantage of the time-local structure and the harmonic components in SSVEP signals, which are both crucial for frequency detection performance. To overcome the limitation, we propose a novel filter bank temporally local MSI (FBTMSI) algorithm to further improve SSVEP frequency detection accuracy. The method explicitly utilizes the temporal information of signal for covariance matrix estimation and employs filter bank decomposition to exploits SSVEP-related harmonic components. RESULTS: We employed the cross-validation strategy on the public Benchmark dataset to optimize the parameters and evaluate the performance of the FBTMSI algorithm. Experimental results show that FBTMSI outperforms the standard MSI, temporally local MSI (TMSI) and filter bank driven MSI (FBMSI) algorithms across multiple experimental settings. In the case of data length of one second, the average accuracy of FBTMSI is 9.85% and 3.15% higher than that of the FBMSI and the TMSI, respectively. CONCLUSIONS: The promising results demonstrate the effectiveness of the FBTMSI algorithm for frequency recognition and show its potential in SSVEP-based BCI applications.


Assuntos
Algoritmos , Interfaces Cérebro-Computador , Eletroencefalografia , Potenciais Evocados Visuais , Humanos , Potenciais Evocados Visuais/fisiologia , Eletroencefalografia/métodos , Processamento de Sinais Assistido por Computador
2.
Neuroimage ; 285: 120501, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38101496

RESUMO

OBJECTIVE: The progression of brain-computer interfaces (BCIs) has been propelled by breakthroughs in neuroscience, signal processing, and machine learning, marking it as a dynamic field of study over the past few decades. Nevertheless, the nonlinear and non-stationary characteristics of steady-state visual evoked potentials (SSVEPs), coupled with the incongruity between frequently employed linear techniques and nonlinear signal attributes, resulted in the subpar performance of mainstream non-training algorithms like canonical correlation analysis (CCA), multivariate synchronization index (MSI), and filter bank CCA (FBCCA) in short-term SSVEP detection. METHODS: To tackle this problem, the novel fusions of common filter bank analysis, CCA dimensionality reduction methods, USSR models, and MSI recognition models are used in SSVEP signal recognition. RESULTS: Unlike conventional linear techniques such as CCA, MSI, and FBCCA, the filter bank second-order underdamped stochastic resonance (FBUSSR) analysis demonstrates superior efficacy in the detection of short-term high-speed SSVEPs. CONCLUSION: This research enlists 32 subjects and uses a public dataset to assess the proposed approach, and the experimental outcomes indicate that the non-training method can attain greater recognition precision and stability. Furthermore, under the conditions of the newly proposed fusion method and light stimulation, the USSR model exhibits the most optimal enhancement effect. SIGNIFICANCE: The findings of this study underscore the expansive potential for the application of BCI systems in the realm of neuroscience and signal processing.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Humanos , Eletroencefalografia/métodos , Potenciais Evocados Visuais , Reconhecimento Psicológico , Aprendizado de Máquina , Algoritmos , Estimulação Luminosa
3.
Sensors (Basel) ; 24(2)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38257527

RESUMO

Switched filter banks find widespread application in frequency-hopping radar systems and communication networks with multiple operating frequencies, especially in situations demanding elevated filter element isolation. In this paper, the design and implementation of a highly isolated switchable narrow-bandpass filter bank architecture using hairpin microstrip topology is presented. The filter bank has four discrete bandpass filters with passbands of 2.0-2.2 GHz, 2.3-2.5 GHz, 3.1-3.3 GHz, and 3.9-4.1 GHz. These filters span the radar S-frequency band (2.0-4.0 GHz). In order to switch between channels with a switching speed of nanoseconds, low-loss and highly isolated SP4T switches are implemented. Advanced design system (ADS) software is used to design the various filter functionalities, and the entire system is tested on a vector network analyzer (VNA). The proposed architecture makes it much easier to put the filter bank into practice and switch it to the desired frequency, which is useful for radar receiver applications.

4.
Sensors (Basel) ; 24(19)2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39409415

RESUMO

In response to the conflicting demands between real-time satellite communication and high-resolution synthetic aperture radar (SAR) imaging, we propose a method that aligns the data transmission rate with the imaging data volume. This approach balances SAR performance with the requirements for real-time data transmission. To meet the need for mobile user terminals to access real-time SAR imagery data of their surroundings without depending on large traditional ground data transmission stations, we developed an application system based on filter bank multicarrier offset quadrature amplitude modulation (FBMC-OQAM). To address the interference problem with SAR signals' transmission and reception, we developed a signal sequence based on spaceborne SAR echo and data transmission and reception. This system enables SAR and data transmission signals to share the same frequency band, radio frequency transmission system, and antenna, creating an integrated sensing and communication system. Simulation experiments showed that, compared to the equal power allocation scheme for subcarriers, the echo image signal-to-noise ratio (SNR) improved by 2.79 dB and the data transmission rate increased by 24.075 Mbps.

5.
Sensors (Basel) ; 24(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38339493

RESUMO

Faults in the ball bearing are a major cause of failure in rotating machinery where ball bearings are used. Therefore, there is a growing demand for ball bearing fault diagnosis to prevent failures in rotating machinery. Although studies on the fault diagnosis of bearing have been conducted using temperature measurements and sound monitoring, these methods have limitations, because they are affected by external noise. Therefore, many researchers have studied vibration monitoring for bearing fault diagnosis. Among these, mel-frequency cepstral coefficients (MFCCs) and 2D convolutional neural networks (CNNs) have attracted significant attention in vibration monitoring schemes. However, the MFCC in existing studies requires a high sampling rate and an expansive frequency band utilization. In addition, 2D CNNs are highly complex. In this study, a rotational characteristic emphasis (RCE) spectrogram process and an optimized CNN were proposed to solve these problems. The RCE spectrogram process analyzes a narrow frequency band and produces low-resolution images. The optimized CNN was designed with a shallow network structure. The experimental results showed an accuracy of 0.9974 for the proposed system. The optimized CNN model has parameters of 5.81 KB and FLOPs of 1.53×106. We demonstrate that the proposed ball bearing fault diagnosis system can achieve high accuracy with low complexity. Thus, we propose a ball bearing fault diagnosis scheme that is applicable to a low sampling rate and changing rotation frequency.

6.
Sensors (Basel) ; 24(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38339748

RESUMO

In order to realize the unsupervised segmentation of subtle defect images on the surface of small magnetic rings and improve the segmentation accuracy and computational efficiency, here, an adaptive threshold segmentation method is proposed based on the improved multi-scale and multi-directional 2D-Gabor filter bank. Firstly, the improved multi-scale and multi-directional 2D-Gabor filter bank was used to filter and reduce the noise on the defect image, suppress the noise pollution inside the target area and the background area, and enhance the difference between the magnetic ring defect and the background. Secondly, this study analyzed the grayscale statistical characteristics of the processed image; the segmentation threshold was constructed according to the gray statistical law of the image; and the adaptive segmentation of subtle defect images on the surface of small magnetic rings was realized. Finally, a classifier based on a BP neural network is designed to classify the scar images and crack images determined by different threshold segmentation methods. The classification accuracies of the iterative method, the OTSU method, the maximum entropy method, and the adaptive threshold segmentation method are, respectively, 85%, 87.5%, 95%, and 97.5%. The adaptive threshold segmentation method proposed in this paper has the highest classification accuracy. Through verification and comparison, the proposed algorithm can segment defects quickly and accurately and suppress noise interference effectively. It is better than other traditional image threshold segmentation methods, validated by both segmentation accuracy and computational efficiency. At the same time, the real-time performance of our algorithm was performed on the advanced SEED-DVS8168 platform.

7.
Appl Intell (Dordr) ; : 1-19, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36777881

RESUMO

Nowadays, the hectic work life of people has led to sleep deprivation. This may further result in sleep-related disorders and adverse physiological conditions. Therefore, sleep study has become an active research area. Sleep scoring is crucial for detecting sleep-related disorders like sleep apnea, insomnia, narcolepsy, periodic leg movement (PLM), and restless leg syndrome (RLS). Sleep is conventionally monitored in a sleep laboratory using polysomnography (PSG) which is the recording of various physiological signals. The traditional sleep stage scoring (SSG) done by professional sleep scorers is a tedious, strenuous, and time-consuming process as it is manual. Hence, developing a machine-learning model for automatic SSG is essential. In this study, we propose an automated SSG approach based on the biorthogonal wavelet filter bank's (BWFB) novel least squares (LS) design. We have utilized a huge Wisconsin sleep cohort (WSC) database in this study. The proposed study is a pioneering work on automatic sleep stage classification using the WSC database, which includes good sleepers and patients suffering from various sleep-related disorders, including apnea, insomnia, hypertension, diabetes, and asthma. To investigate the generalization of the proposed system, we evaluated the proposed model with the following publicly available databases: cyclic alternating pattern (CAP), sleep EDF, ISRUC, MIT-BIH, and the sleep apnea database from St. Vincent's University. This study uses only two unipolar EEG channels, namely O1-M2 and C3-M2, for the scoring. The Hjorth parameters (HP) are extracted from the wavelet subbands (SBS) that are obtained from the optimal BWFB. To classify sleep stages, the HP features are fed to several supervised machine learning classifiers. 12 different datasets have been created to develop a robust model. A total of 12 classification tasks (CT) have been conducted employing various classification algorithms. Our developed model achieved the best accuracy of 83.2% and Cohen's Kappa of 0.7345 to reliably distinguish five sleep stages, using an ensemble bagged tree classifier with 10-fold cross-validation using WSC data. We also observed that our system is either better or competitive with existing state-of-art systems when we tested with the above-mentioned five databases other than WSC. This method yielded promising results using only two EEG channels using a huge WSC database. Our approach is simple and hence, the developed model can be installed in home-based clinical systems and wearable devices for sleep scoring.

8.
Sensors (Basel) ; 22(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35062470

RESUMO

A variety of feature extraction and classification approaches have been proposed using electrocardiogram (ECG) and ECG-derived signals for improving the performance of detecting apnea events and diagnosing patients with obstructive sleep apnea (OSA). The purpose of this study is to further evaluate whether the reduction of lower frequency P and T waves can increase the accuracy of the detection of apnea events. This study proposed filter bank decomposition to decompose the ECG signal into 15 subband signals, and a one-dimensional (1D) convolutional neural network (CNN) model independently cooperating with each subband to extract and classify the features of the given subband signal. One-minute ECG signals obtained from the MIT PhysioNet Apnea-ECG database were used to train the CNN models and test the accuracy of detecting apnea events for different subbands. The results show that the use of the newly selected subject-independent datasets can avoid the overestimation of the accuracy of the apnea event detection and can test the difference in the accuracy of different subbands. The frequency band of 31.25-37.5 Hz can achieve 100% per-recording accuracy with 85.8% per-minute accuracy using the newly selected subject-independent datasets and is recommended as a promising subband of ECG signals that can cooperate with the proposed 1D CNN model for the diagnosis of OSA.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Algoritmos , Eletrocardiografia , Humanos , Redes Neurais de Computação , Polissonografia , Síndromes da Apneia do Sono/diagnóstico , Apneia Obstrutiva do Sono/diagnóstico
9.
Sensors (Basel) ; 22(17)2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36080970

RESUMO

The purpose of this work is to present a flexible system that supports the study of wideband underwater acoustic communications (UAC). It has been developed both to measure channels and to test transmission techniques under realistic conditions in the ultrasonic band. This platform consists of a hardware (HW) part that includes multiple hydrophones, projectors, analog front-ends, acquisition boards, and computers, and a software (SW) part for the generation, reception, and management of acoustic sounding signals and noise. UAC channels are among the most hostile ones and exhibit an important attenuation and distortion, essentially due to both multipath propagation, which results in a very long channel impulse response, and time-varying behavior, which produces a notable Doppler spread. To cope with this challenging medium, sophisticated transmission techniques must be employed. In this sense, adequate signal processing algorithms have been designed aiming not only at the analysis and characterization of underwater communication channels but also at the evaluation of diverse modulation, detection, and coding schemes, from Orthogonal Frequency Division Multiplexing (OFDM) to single-carrier digital modulations with a single-input multiple-output (SIMO) configuration that takes advantage of diversity techniques. Wideband sounding signals, to be injected into the sea from the transmitter side, are created with patterns that allow multiple tests on a batch. With offline processing of the captured data at the receiver side, different trials can be carried out in a very flexible manner. The different aspects of the platform are described in detail: the HW equipment used, the SW interface to control acquisition boards, and the signal processing algorithms to estimate the UAC channel response. The platform allows the analysis and design of new proposals for underwater communications systems that improve the performance of the current ones.


Assuntos
Modelos Teóricos , Ultrassom , Comunicação , Computadores , Software
10.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 38(5): 969-978, 2021 Oct 25.
Artigo em Zh | MEDLINE | ID: mdl-34713665

RESUMO

Automatic classification of heart sounds plays an important role in the early diagnosis of congenital heart disease. A kind of heart sound classification algorithms based on sub-band envelope feature and convolution neural network was proposed in this paper, which did not need to segment the heart sounds according to cardiac cycle accurately. Firstly, the heart sound signal was divided into some frames. Then, the frame level heart sound signal was filtered with Gammatone filter bank to obtain the sub-band signals. Next, the sub-band envelope was extracted by Hilbert transform. After that, the sub-band envelope was stacked into a feature map. Finally, type Ⅰ and type Ⅱ convolution neural network were selected as classifier. The result shown that the sub-band envelope feature was better in type Ⅰ than type Ⅱ. The algorithm is tested with 1 000 heart sound samples. The test results show that the overall performance of the algorithm proposed in this paper is significantly improved compared with other similar algorithms, which provides a new method for automatic classification of congenital heart disease, and speeds up the process of automatic classification of heart sounds applied to the actual screening.


Assuntos
Cardiopatias Congênitas , Ruídos Cardíacos , Algoritmos , Coração , Cardiopatias Congênitas/diagnóstico , Humanos , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador
11.
Sensors (Basel) ; 20(21)2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33182465

RESUMO

A blind discrete-cosine-transform-based phase noise compensation (BD-PNC) is proposed to compensate the inter-carrier-interference (ICI) in the coherent optical offset-quadrature amplitude modulation (OQAM)-based filter-bank multicarrier (CO-FBMC/OQAM) transmission system. Since the phase noise sample can be approximated by an expansion of the discrete cosine transform (DCT) in the time-domain, a time-domain compensation model is built for the transmission system. According to the model, phase noise compensation (PNC) depends only on its DCT coefficients. The common phase error (CPE) compensation is firstly performed for the received signal. After that, a pre-decision is made on a part of compensated signals with low decision error probability, and the pre-decision results are used as the estimated values of transmitted signals to calculate the DCT coefficients. Such a partial pre-decision process reduces not only decision error but also the complexity of the BD-PNC method while keeping almost the same performance as in the case of the pre-decision of all compensated signals. Numerical simulations are performed to evaluate the performance of the proposed scheme for a 30 GBaud CO-FBMC/OQAM system. The simulation results show that its bit error rate (BER) performance is improved by more than one order of magnitude through the mitigation of the ICI in comparison with the traditional blind PNC scheme only aiming for CPE compensation.

12.
J Med Syst ; 44(6): 114, 2020 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-32388733

RESUMO

Atrial fibrillation (AF) is a cardiac arrhythmia which is characterized based on the irregsular beating of atria, resulting in, the abnormal atrial patterns that are observed in the electrocardiogram (ECG) signal. The early detection of this pathology is very helpful for minimizing the chances of stroke, other heart-related disorders, and coronary artery diseases. This paper proposes a novel method for the detection of AF pathology based on the analysis of the ECG signal. The method adopts a multi-rate cosine filter bank architecture for the evaluation of coefficients from the ECG signal at different subbands, in turn, the Fractional norm (FN) feature is evaluated from the extracted coefficients at each subband. Then, the AF detection is carried out using a deep learning approach known as the Hierarchical Extreme Learning Machine (H-ELM) from the FN features. The proposed method is evaluated by considering normal and AF pathological ECG signals from public databases. The experimental results reveal that the proposed multi-rate cosine filter bank based on FN features is effective for the detection of AF pathology with an accuracy, sensitivity and specificity values of 99.40%, 98.77%, and 100%, respectively. The performance of the proposed diagnostic features of the ECG signal is compared with other existing features for the detection of AF. The low-frequency subband FN features found to be more significant with a difference of the mean values as 0.69 between normal and AF classes.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Aprendizado de Máquina , Redes Neurais de Computação , Algoritmos , Humanos , Processamento de Sinais Assistido por Computador/instrumentação
13.
Entropy (Basel) ; 22(12)2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33334058

RESUMO

The design of a computer-aided system for identifying the seizure onset zone (SOZ) from interictal and ictal electroencephalograms (EEGs) is desired by epileptologists. This study aims to introduce the statistical features of high-frequency components (HFCs) in interictal intracranial electroencephalograms (iEEGs) to identify the possible seizure onset zone (SOZ) channels. It is known that the activity of HFCs in interictal iEEGs, including ripple and fast ripple bands, is associated with epileptic seizures. This paper proposes to decompose multi-channel interictal iEEG signals into a number of subbands. For every 20 s segment, twelve features are computed from each subband. A mutual information (MI)-based method with grid search was applied to select the most prominent bands and features. A gradient-boosting decision tree-based algorithm called LightGBM was used to score each segment of the channels and these were averaged together to achieve a final score for each channel. The possible SOZ channels were localized based on the higher value channels. The experimental results with eleven epilepsy patients were tested to observe the efficiency of the proposed design compared to the state-of-the-art methods.

14.
Sensors (Basel) ; 19(22)2019 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-31766276

RESUMO

The assessment of transformations in the retinal vascular structure has a strong potential in indicating a wide range of underlying ocular pathologies. Correctly identifying the retinal vessel map is a crucial step in disease identification, severity progression assessment, and appropriate treatment. Marking the vessels manually by a human expert is a tedious and time-consuming task, thereby reinforcing the need for automated algorithms capable of quick segmentation of retinal features and any possible anomalies. Techniques based on unsupervised learning methods utilize vessel morphology to classify vessel pixels. This study proposes a directional multi-scale line detector technique for the segmentation of retinal vessels with the prime focus on the tiny vessels that are most difficult to segment out. Constructing a directional line-detector, and using it on images having only the features oriented along the detector's direction, significantly improves the detection accuracy of the algorithm. The finishing step involves a binarization operation, which is again directional in nature, helps in achieving further performance improvements in terms of key performance indicators. The proposed method is observed to obtain a sensitivity of 0.8043, 0.8011, and 0.7974 for the Digital Retinal Images for Vessel Extraction (DRIVE), STructured Analysis of the Retina (STARE), and Child Heart And health Study in England (CHASE_DB1) datasets, respectively. These results, along with other performance enhancements demonstrated by the conducted experimental evaluation, establish the validity and applicability of directional multi-scale line detectors as a competitive framework for retinal image segmentation.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Vasos Retinianos/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Bases de Dados como Assunto , Difusão , Fundo de Olho , Humanos , Pessoa de Meia-Idade
15.
Sensors (Basel) ; 19(7)2019 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-30978978

RESUMO

Single-trial motor imagery classification is a crucial aspect of brain-computer applications. Therefore, it is necessary to extract and discriminate signal features involving motor imagery movements. Riemannian geometry-based feature extraction methods are effective when designing these types of motor-imagery-based brain-computer interface applications. In the field of information theory, Riemannian geometry is mainly used with covariance matrices. Accordingly, investigations showed that if the method is used after the execution of the filterbank approach, the covariance matrix preserves the frequency and spatial information of the signal. Deep-learning methods are superior when the data availability is abundant and while there is a large number of features. The purpose of this study is to a) show how to use a single deep-learning-based classifier in conjunction with BCI (brain-computer interface) applications with the CSP (common spatial features) and the Riemannian geometry feature extraction methods in BCI applications and to b) describe one of the wrapper feature-selection algorithms, referred to as the particle swarm optimization, in combination with a decision tree algorithm. In this work, the CSP method was used for a multiclass case by using only one classifier. Additionally, a combination of power spectrum density features with covariance matrices mapped onto the tangent space of a Riemannian manifold was used. Furthermore, the particle swarm optimization method was implied to ease the training by penalizing bad features, and the moving windows method was used for augmentation. After empirical study, the convolutional neural network was adopted to classify the pre-processed data. Our proposed method improved the classification accuracy for several subjects that comprised the well-known BCI competition IV 2a dataset.


Assuntos
Interfaces Cérebro-Computador , Encéfalo/fisiologia , Eletroencefalografia/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Árvores de Decisões , Aprendizado Profundo , Humanos , Modelos Teóricos , Movimento/fisiologia , Redes Neurais de Computação , Software
16.
Neurocomputing (Amst) ; 343: 154-166, 2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32226230

RESUMO

The non-stationary nature of electroencephalography (EEG) signals makes an EEG-based brain-computer interface (BCI) a dynamic system, thus improving its performance is a challenging task. In addition, it is well-known that due to non-stationarity based covariate shifts, the input data distributions of EEG-based BCI systems change during inter- and intra-session transitions, which poses great difficulty for developments of online adaptive data-driven systems. Ensemble learning approaches have been used previously to tackle this challenge. However, passive scheme based implementation leads to poor efficiency while increasing high computational cost. This paper presents a novel integration of covariate shift estimation and unsupervised adaptive ensemble learning (CSE-UAEL) to tackle non-stationarity in motor-imagery (MI) related EEG classification. The proposed method first employs an exponentially weighted moving average model to detect the covariate shifts in the common spatial pattern features extracted from MI related brain responses. Then, a classifier ensemble was created and updated over time to account for changes in streaming input data distribution wherein new classifiers are added to the ensemble in accordance with estimated shifts. Furthermore, using two publicly available BCI-related EEG datasets, the proposed method was extensively compared with the state-of-the-art single-classifier based passive scheme, single-classifier based active scheme and ensemble based passive schemes. The experimental results show that the proposed active scheme based ensemble learning algorithm significantly enhances the BCI performance in MI classifications.

17.
Sensors (Basel) ; 18(4)2018 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-29659510

RESUMO

Rolling bearings are important components in rotary machinery systems. In the field of multi-fault diagnosis of rolling bearings, the vibration signal collected from single channels tends to miss some fault characteristic information. Using multiple sensors to collect signals at different locations on the machine to obtain multivariate signal can remedy this problem. The adverse effect of a power imbalance between the various channels is inevitable, and unfavorable for multivariate signal processing. As a useful, multivariate signal processing method, Adaptive-projection has intrinsically transformed multivariate empirical mode decomposition (APIT-MEMD), and exhibits better performance than MEMD by adopting adaptive projection strategy in order to alleviate power imbalances. The filter bank properties of APIT-MEMD are also adopted to enable more accurate and stable intrinsic mode functions (IMFs), and to ease mode mixing problems in multi-fault frequency extractions. By aligning IMF sets into a third order tensor, high order singular value decomposition (HOSVD) can be employed to estimate the fault number. The fault correlation factor (FCF) analysis is used to conduct correlation analysis, in order to determine effective IMFs; the characteristic frequencies of multi-faults can then be extracted. Numerical simulations and the application of multi-fault situation can demonstrate that the proposed method is promising in multi-fault diagnoses of multivariate rolling bearing signal.

18.
J Med Syst ; 42(6): 102, 2018 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-29675598

RESUMO

Bradycardia can be modulated using the cardiac pacemaker, an implantable medical device which sets and balances the patient's cardiac health. The device has been widely used to detect and monitor the patient's heart rate. The data collected hence has the highest authenticity assurance and is convenient for further electric stimulation. In the pacemaker, ECG detector is one of the most important element. The device is available in its new digital form, which is more efficient and accurate in performance with the added advantage of economical power consumption platform. In this work, a joint algorithm based on biorthogonal wavelet transform and run-length encoding (RLE) is proposed for QRS complex detection of the ECG signal and compressing the detected ECG data. Biorthogonal wavelet transform of the input ECG signal is first calculated using a modified demand based filter bank architecture which consists of a series combination of three lowpass filters with a highpass filter. Lowpass and highpass filters are realized using a linear phase structure which reduces the hardware cost of the proposed design approximately by 50%. Then, the location of the R-peak is found by comparing the denoised ECG signal with the threshold value. The proposed R-peak detector achieves the highest sensitivity and positive predictivity of 99.75 and 99.98 respectively with the MIT-BIH arrhythmia database. Also, the proposed R-peak detector achieves a comparatively low data error rate (DER) of 0.002. The use of RLE for the compression of detected ECG data achieves a higher compression ratio (CR) of 17.1. To justify the effectiveness of the proposed algorithm, the results have been compared with the existing methods, like Huffman coding/simple predictor, Huffman coding/adaptive, and slope predictor/fixed length packaging.


Assuntos
Algoritmos , Compressão de Dados/métodos , Eletrocardiografia/métodos , Análise de Ondaletas , Desenho de Equipamento , Humanos , Marca-Passo Artificial , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
19.
Sensors (Basel) ; 17(7)2017 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-28704945

RESUMO

In this paper, a data compression technology-based intelligent data acquisition (IDAQ) system was developed for structural health monitoring of civil structures, and its validity was tested using random signals (El-Centro seismic waveform). The IDAQ system was structured to include a high-performance CPU with large dynamic memory for multi-input and output in a radio frequency (RF) manner. In addition, the embedded software technology (EST) has been applied to it to implement diverse logics needed in the process of acquiring, processing and transmitting data. In order to utilize IDAQ system for the structural health monitoring of civil structures, this study developed an artificial filter bank by which structural dynamic responses (acceleration) were efficiently acquired, and also optimized it on the random El-Centro seismic waveform. All techniques developed in this study have been embedded to our system. The data compression technology-based IDAQ system was proven valid in acquiring valid signals in a compressed size.


Assuntos
Compressão de Dados , Aceleração , Algoritmos , Processamento de Sinais Assistido por Computador , Software
20.
J Med Syst ; 42(1): 11, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29177558

RESUMO

In this paper, an overall framework has been presented for person verification using ear biometric which uses tunable filter bank as local feature extractor. The tunable filter bank, based on a half-band polynomial of 14th order, extracts distinct features from ear images maintaining its frequency selectivity property. To advocate the applicability of tunable filter bank on ear biometrics, recognition test has been performed on available constrained databases like AMI, WPUT, IITD and unconstrained database like UERC. Experiments have been conducted applying tunable filter based feature extractor on subparts of the ear. Empirical experiments have been conducted with four and six subdivisions of the ear image. Analyzing the experimental results, it has been found that tunable filter moderately succeeds to distinguish ear features at par with the state-of-the-art features used for ear recognition. Accuracies of 70.58%, 67.01%, 81.98%, and 57.75% have been achieved on AMI, WPUT, IITD, and UERC databases through considering Canberra Distance as underlying measure of separation. The performances indicate that tunable filter is a candidate for recognizing human from ear images.


Assuntos
Identificação Biométrica/métodos , Orelha/anatomia & histologia , Reconhecimento Automatizado de Padrão/métodos , Análise de Ondaletas , Adolescente , Adulto , Inteligência Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA