Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pediatr Cardiol ; 43(4): 821-826, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34988600

RESUMO

More than ten years have passed since data collection was initiated in the IMPACT registry. Over the last decade, difficulties in data access and a lack of autonomy have led to a disengagement of the congenital community, with the usefulness of IMPACT to patients and providers being questioned. This article outlines some of problems identified using an online survey among interventional congenital cardiologists, and provides possible solutions for the future.


Assuntos
Cardiologistas , Cardiopatias Congênitas , Cateterismo Cardíaco , Humanos , Sistema de Registros , Inquéritos e Questionários
2.
Cardiol Young ; 26(1): 70-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25705856

RESUMO

OBJECTIVES: To report procedural characteristics and adverse events on data collected in the registry. BACKGROUND: The IMPACT--IMproving Paediatric and Adult Congenital Treatment--Registry is a catheterisation registry of paediatric and adult patients with CHD undergoing diagnostic and interventional cardiac catheterisation. We are reporting the procedural characteristics and adverse events of patients undergoing diagnostic and interventional catheterisation procedures from January, 2011 to March, 2013. METHODS: Demographic, clinical, procedural, and institutional data elements were collected at the participating centres and entered via either a web-based platform or software provided by American College of Cardiology-certified vendors, and were collected in a secure, centralised database. Centre participation was voluntary. RESULTS: During the time frame of data collection, 19,797 procedures were entered into the IMPACT Registry. Procedures were classified as diagnostic only (35.4%); one of six specific interventions (23.8%); other or multiple interventions (40.7%); and were further broken down into four age groups. Anaesthesia was used in 84.1% of diagnostic procedures and 87.8% of interventional ones. Adverse events occurred in 10.0% of diagnostic and 11.1% of interventional procedures. CONCLUSIONS: The IMPACT Registry is gathering data to set national benchmarks for diagnostic and certain specific interventional procedures. We are seeing little differences in procedural characteristics or adverse events in diagnostic procedures compared with interventional procedures overall, but there is significant variation in adverse events amongst age categories. Risk stratification and patient acuity scores will be required for further analysis of these differences.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Adulto , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Sistema de Registros
3.
JACC Cardiovasc Interv ; 10(17): 1729-1737, 2017 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-28823780

RESUMO

OBJECTIVES: The authors sought to identify risk factors associated with major adverse events (MAEs) in infants <6 kg undergoing transcatheter patent ductus arteriosus (PDA) occlusion. BACKGROUND: Transcatheter PDA occlusion is among the safest of interventional cardiac procedures in adults and older children, but use among infants <6 kg has not been characterized adequately. METHODS: Using the IMPACT (IMproving Pediatric and Adult Congenital Treatments) registry, we identified infants <6 kg undergoing transcatheter PDA occlusion (January 1, 2011, to March 1, 2015). Using mixed-effects multivariate regression, the authors assessed characteristics predictive of MAE or composite failure (procedural failure or MAE). Individual safety metrics (e.g., embolization, malposition) were also examined for differences across weight thresholds: extremely low weight (LW) (<2 kg), very LW (2 to <4 kg), and LW (4 to <6 kg). RESULTS: Transcatheter PDA occlusion was attempted in 747 infants <6 kg at 73 hospitals. Rate of procedural success was 94.3%. MAEs were observed in 12.6% of cases; the most common events were acute arterial injury and device embolization in 3.5% and 2.4% of cases, respectively. Younger age (<30 days) was associated with greater risk of a MAE (risk ratio: 3.3; 95% confidence interval: 1.5 to 7.6) and composite failure (risk ratio: 3.0; 95% confidence interval: 1.4 to 6.7). Risk of embolization was higher among extremely LW (10.5%) than very LW or LW infants (1.6% and 2.5%, respectively; p = 0.050). CONCLUSIONS: Among infants <6 kg, transcatheter PDA occlusion is technically feasible, but risks of MAE are noteworthy. These findings may help inform patient selection and procedural approach for transcatheter PDA occlusion and direct targeted research efforts to support the practice of evidence-based medicine.


Assuntos
Peso Corporal , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Análise Multivariada , Razão de Chances , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA