Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.120
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(34): e2300856120, 2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37579165

RESUMO

Space heating and cooling consume ~13% of global energy every year. The development of advanced materials that promote energy savings in heating and cooling is gaining increasing attention. To thermally isolate the space of concern and minimize the heat exchange with the outside environment has been recognized as one effective solution. To this end, here, we develop a universal category of colorful low-emissivity paints to form bilayer coatings consisting of an infrared (IR)-reflective bottom layer and an IR-transparent top layer in colors. The colorful visual appearance ensures the aesthetical effect comparable to conventional paints. High mid-infrared reflectance (up to ~80%) is achieved, which is more than 10 times as conventional paints in the same colors, efficiently reducing both heat gain and loss from/to the outside environment. The high near-IR reflectance also benefits reducing solar heat gain in hot days. The advantageous features of these paints strike a balance between energy savings and penalties for heating and cooling throughout the year, providing a comprehensive year-round energy-saving solution adaptable to a wide variety of climatic zones. Taking a typical midrise apartment building as an example, the application of our colorful low-emissivity paints can realize positive heating, ventilation, and air conditioning energy saving, up to 27.24 MJ/m2/y (corresponding to the 7.4% saving ratio). Moreover, the versatility of the paint, along with its applicability to diverse surfaces of various shapes and materials, makes the paints extensively useful in a range of scenarios, including building envelopes, transportation, and storage.

2.
J Neurosci ; 43(13): 2260-2276, 2023 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-36801823

RESUMO

Glia are essential to protecting and enabling nervous system function and a key glial function is the formation of the glial sheath around peripheral axons. Each peripheral nerve in the Drosophila larva is ensheathed by three glial layers, which structurally support and insulate the peripheral axons. How peripheral glia communicate with each other and between layers is not well established and we investigated the role of Innexins in mediating glial function in the Drosophila periphery. Of the eight Drosophila Innexins, we found two (Inx1 and Inx2) are important for peripheral glia development. In particular loss of Inx1 and Inx2 resulted in defects in the wrapping glia leading to disruption of the glia wrap. Of interest loss of Inx2 in the subperineurial glia also resulted in defects in the neighboring wrapping glia. Inx plaques were observed between the subperineurial glia and the wrapping glia suggesting that gap junctions link these two glial cell types. We found Inx2 is key to Ca2+ pulses in the peripheral subperineurial glia but not in the wrapping glia, and we found no evidence of gap junction communication between subperineurial and wrapping glia. Rather we have clear evidence that Inx2 plays an adhesive and channel-independent role between the subperineurial and wrapping glia to ensure the integrity of the glial wrap.SIGNIFICANCE STATEMENT Gap junctions are critical for glia communication and formation of myelin in myelinating glia. However, the role of gap junctions in non-myelinating glia is not well studied, yet non-myelinating glia are critical for peripheral nerve function. We found the Innexin gap junction proteins are present between different classes of peripheral glia in Drosophila. Here Innexins form junctions to facilitate adhesion between the different glia but do so in a channel-independent manner. Loss of adhesion leads to disruption of the glial wrap around axons and leads to fragmentation of the wrapping glia membranes. Our work points to an important role for gap junction proteins in mediating insulation by non-myelinating glia.


Assuntos
Proteínas de Drosophila , Animais , Proteínas de Drosophila/genética , Proteínas de Drosophila/metabolismo , Neuroglia/metabolismo , Sistema Nervoso Periférico/metabolismo , Drosophila/metabolismo , Axônios/metabolismo , Conexinas/genética , Conexinas/metabolismo
3.
Small ; 20(8): e2305453, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37840417

RESUMO

Morphology regulation and composition design have proved to be effective strategies for the fabrication of desirable microwave absorbers. However, it is still challenging to precisely control the microstructure and components of MAX phases. Herein, an entropy-driven approach, a transition from irregular grains (low entropy) to sheet structure (high entropy), is proposed to modulate the morphology of MAX phases. The theoretical calculation indicates that the morphology evolution can be ascribed to the enlarged energy difference between (11_00) and (0001) facets. The enriched structural defects and optimized morphologies yield significant dipolar polarization, interfacial polarization, multiple reflections, and scattering, which all enhance the electromagnetic wave absorption performance of (V0.25 Ti0.25 Cr0.25 Mo0.25 )2 GaC. Specifically, its minimum reflection loss can reach up to -47.12 dB at 12.13 GHz, and the optimal effective absorption bandwidth is 4.56 GHz (2.03 mm). Meanwhile, (V0.25 Ti0.25 Cr0.25 Mo0.25 )2 GaC shows also pronounced thermal insulation properties affording it good reliability in the harsh working environment. This work offers a novel approach to designing and regulating the morphology of the high entropy MAX phase, and also presents an opportunity to elucidate the relationship between entropy and electromagnetic wave absorption performance.

4.
Small ; : e2403931, 2024 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-39128129

RESUMO

Organic aerogels are emerging as promising materials due to their versatile properties, rendering them excellent candidates for a variety of applications in the fields of thermal insulation, energy storage, pharmaceuticals, chemical adsorption, and catalysis. However, current aerogel designs rely on cross-linked polymer networks, which lack efficient end-of-use solutions, thereby hindering their overall sustainability. In this study, a facile synthesis of organic aerogels with a unique combination of imine and cyanurate moieties is presented, resulting in high-performance, lightweight insulating materials. The aerogels' structure, ensures mechanical robustness, thermal resistance, and hydrophobicity without additional treatments, crucial for long-term performance. Additionally, in response to the currently unsustainable use of cross-linked polymer materials, the molecular design offers diverse avenues of chemical recycling. These include full depolymerization back into the original monomers, partial network fragmentation producing soluble oligomers that can be promptly employed to fabricate new aerogels, and upcycling of aerogel waste into useful building blocks. This work pioneers a novel approach to material design, emphasizing recyclability as a core feature while maintaining high-performance excellence.

5.
Small ; : e2401283, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38924314

RESUMO

Fibrillated cellulose-based nanocomposites can improve energy efficiency of building envelopes, especially windows, but efficiently engineering them with a flexible ability of lighting and thermal management remains highly challenging. Herein, a scalable interfacial engineering strategy is developed to fabricate haze-tunable thermal barrier films tailored with phosphorylated cellulose nanofibrils (PCNFs). Clear films with an extremely low haze of 1.6% (glass-scale) are obtained by heat-assisted surface void packing without hydrophobization of nanocellulose. PCNF gel cakes serve here as templates for surface roughening, thereby resulting in a high haze (73.8%), and the roughened films can block heat transfer by increasing solar reflection in addition to a reduced thermal conduction. Additionally, obtained films can tune distribution of light from visible to near-infrared spectral range, enabling uniform colored lighting and inhibiting localized heating. Furthermore, an integrated simulation of lighting and cooling energy consumption in the case of office buildings shows that the film can reduce the total energy use by 19.2-38.1% under reduced lighting levels. Such a scalable and versatile engineering strategy provides an opportunity to endow nanocellulose-reinforced materials with tunable optical and thermal functionalities, moving their practical applications in green buildings forward.

6.
Small ; : e2401742, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38721985

RESUMO

There is a growing demand for thermal management materials in electronic fields. Aerogels have attracted interest due to their extremely low density and extraordinary thermal insulation properties. However, the application of aerogels is limited by high production costs and the requirement that aerogel structures not be load-bearing. In this study, mullite-reinforced SiC-based aerogel composite (MR-SiC AC) is prepared through 3D printing combined with in situ growth of SiC nanowires in post processing. The fabricated MR-SiC AC not only has ultra-low thermal conductivity (0.021 W K m-1) and high porosity (90.0%), but also a high Young's modulus (24.4 MPa) and high compressive strength (1.65 MPa), both exceeding the measurements of existing resilient aerogels by an order of magnitude. These properties make MR-SiC AC an ideal solution for the precision thermal management of lightweight structures having complex geometry for functional devices.

7.
Small ; 20(23): e2308145, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38150646

RESUMO

Carbon fiber composites have great application prospects as a potential electromagnetic (EM) wave-absorbing material, yet it remains extremely challenging to integrate multiple functions of EM wave absorption, mechanical strength, thermal insulation, and flame retardancy. Herein, a novel carbon fiber reinforced C/SiOC aerogel (CF/CS) composite is successfully prepared by sol-gel impregnation combined with an ambient drying process for the first time. The density of the obtained CF/CS composites can be controlled just by changing sol-gel impregnation cycles (original carbon fiber felt (S0), and samples with one (S1) and two (S2) impregnation cycles are 0.249, 0.324, and 0.402 g cm-3, respectively), allowing for efficient tuning of their properties. Remarkably, S2 displays excellent microwave absorption properties, with an optimal reflection loss of -65.45 dB, which is significantly improved than S0 (-10.90 dB). Simultaneously, compared with S0 (0.75 and 0.30 MPa in the x/y and z directions), the mechanical performance of S2 is dramatically improved with a maximum compressive strength of 10.37 and 4.93 MPa in the x/y and z directions, respectively. Moreover, CF/CS composites show superior thermal insulation capability than S0 and obtain good flame-retardant properties. This work provides valuable guidance and inspiration for the development of multifunctional EM wave absorbers.

8.
Small ; : e2402423, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38845523

RESUMO

Electromagnetic protection in extreme environments requires materials with excellent thermal insulation capability and mechanical property to withstand severe temperature fluctuations and complex external stresses. Achieving strong electromagnetic wave absorption (EMA) while sustaining these exceptional properties remains a significant challenge. Herein, a facile approach is demonstrated to fabricate a biomimetic leaf-vein MXene/CNTs/PI (MCP) aerogel with parallel venations through bidirectional freeze-casting method. Due to its multi-arch lamellar structure and parallel venations within the aerogel layers, the ultralight MCP aerogel (16.9 mg·cm-3) achieves a minimum reflection loss (RLmin) of -75.8 dB and a maximum effective absorption bandwidth (EABmax) of 7.14 GHz with an absorber content of only 2.4 wt%, which also exhibits superelasticity and structural stability over a wide temperature range from -196 to 400 °C. Moreover, this unique structure facilitates rapid heat dissipation within the layers, while significantly impeding heat transfer between adjacent layers, achieving an ultralow thermal conductivity of 15.3 mW·m-1·K-1 for thermal superinsulation. The combination of excellent EMA performance, robust structural stability, and thermal superinsulation provides a potential design scheme under extreme conditions, especially in aerospace applications.

9.
Nanotechnology ; 35(13)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38134441

RESUMO

In aerospace and downhole exploration, materials must function reliably in challenging environments characterized by high temperatures and complex electromagnetic (EM) interference. Graphene oxide (GO) aerogels are promising materials for thermal insulation, and the incorporation of silicon carbide nanowires can enhance their mechanical properties, thermal stability and EM absorption efficiency. In this context, citric acid acts as both a cross-linking and reducing agent, facilitating the formation of a composite aerogel comprising GO and SiC nanowires (rGO/m-SiC NWs). Compared with GO aerogels, the representative composite aerogel sample rGS4 demonstrated significantly improved mechanical properties (yield strength increased by 0.031 MPa), outstanding thermal stability (ability to withstand temperatures up to 800 °C) and remarkably low thermal conductivity (measuring just 0.061 W m-1K-1). Importantly, the composite aerogels displayed impressive EM absorption characteristics, including a slim profile (2.5 mm), high absorption capacity (-42.23 dB) and an exceptionally broad effective absorption bandwidth (7.47 GHz). Notably, the specific effective absorption bandwidth of composite aerogels exceeded that of similar composite materials. In conclusion, rGO/m-SiC NWs exhibited exceptional mechanical properties, remarkable thermal stability, efficient thermal insulation and outstanding microwave absorption capabilities. These findings highlight their potential for use in high-temperature and electromagnetically challenging environments.

10.
Environ Sci Technol ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958382

RESUMO

With the annual global electricity production exceeding 30,000 TWh, the safe transmission of electric power has been heavily relying on SF6, the most potent industrial greenhouse gas. While promising SF6 alternatives have been proposed, their compatibilities with materials used in gas-insulated equipment (GIE) must be thoroughly studied. This is particularly true as the emerging SF6 alternatives generally leverage their relatively higher reactivity to achieve lower global warming potentials (GWPs). Here, a high-throughput compatibility screening of common GIE materials was conducted with a representative SF6 alternative, namely, C4F7N (2,3,3,3-tetrafluoro-2-(trifluoromethyl)propanenitrile)/CO2 gas mixtures. In this screening, the insulation performance of C4F7N/CO2 gas mixtures, as an indicator of the C4F7N/materials compatibility level, was periodically monitored during the thermal aging with tens of materials from SF6-insulated GIE, including desiccants/adsorbents, rubber, plastics, composites, ceramics, metals, etc. The identification of incompatible materials and the follow-up mechanism studies suggested that the acidity of materials represents the primary cause for C4F7N/materials incompatibility when C4F7N/CO2 gas mixtures are used as a drop-in replacement solution for existing SF6-insulated apparatuses. Mitigation strategies tackling the acidity of materials were then proposed and validated. Additionally, the amphoteric characteristics of C4F7N were briefly discussed. This work provides insight into the materials incompatibility of SF6 alternatives, along with validated mitigation strategies, for the selection and design of materials used in future eco-friendly GIE.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38683872

RESUMO

Although ventricular capture during the atrial threshold test is possible, there are rare reports on the insulation defect and inactive leads thereof. In this case, we present a pacemaker-dependent patient with a history of pacemaker generator replacements. The patient experienced ventricular capture induced by atrial pacing due to adhesion of the atrial and ventricular leads with an insulation defect. The atrial lead was abandoned and a new lead was implanted. However, there was a significant decrease in ventricular impedance detected shortly after the new lead was implanted. When observing the phenomenon of atrial pacing-induced ventricular depolarization, one uncommon reason to consider is lead adhesive wear. It is important to pay attention to the contact and bending sites of the leads.

12.
Proc Natl Acad Sci U S A ; 118(41)2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34615716

RESUMO

Understanding kinetic control of biological processes is as important as identifying components that constitute pathways. Insulin signaling is central for almost all metazoans, and its perturbations are associated with various developmental disorders, metabolic diseases, and aging. While temporal phosphorylation changes and kinetic constants have provided some insights, constant or variable parameters that establish and maintain signal topology are poorly understood. Here, we report kinetic parameters that encode insulin concentration and nutrient-dependent flow of information using iterative experimental and mathematical simulation-based approaches. Our results illustrate how dynamics of distinct phosphorylation events collectively contribute to selective kinetic gating of signals and maximum connectivity of the signaling cascade under normo-insulinemic but not hyper-insulinemic states. In addition to identifying parameters that provide predictive value for maintaining the balance between metabolic and growth-factor arms, we posit a kinetic basis for the emergence of insulin resistance. Given that pulsatile insulin secretion during a fasted state precedes a fed response, our findings reveal rewiring of insulin signaling akin to memory and anticipation, which was hitherto unknown. Striking disparate temporal behavior of key phosphorylation events that destroy the topology under hyper-insulinemic states underscores the importance of unraveling regulatory components that act as bandwidth filters. In conclusion, besides providing fundamental insights, our study will help in identifying therapeutic strategies that conserve coupling between metabolic and growth-factor arms, which is lost in diseases and conditions of hyper-insulinemia.


Assuntos
Glicemia/análise , Jejum/sangue , Hepatócitos/metabolismo , Hiperinsulinismo/metabolismo , Resistência à Insulina/fisiologia , Insulina/metabolismo , Animais , Células Cultivadas , Simulação por Computador , Hiperinsulinismo/sangue , Insulina/sangue , Camundongos , Modelos Teóricos , Fosforilação , Transdução de Sinais/fisiologia
13.
Proc Natl Acad Sci U S A ; 118(7)2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33558242

RESUMO

The Myc-associated zinc finger protein (MAZ) is often found at genomic binding sites adjacent to CTCF, a protein which affects large-scale genome organization through its interaction with cohesin. We show here that, like CTCF, MAZ physically interacts with a cohesin subunit and can arrest cohesin sliding independently of CTCF. It also shares with CTCF the ability to independently pause the elongating form of RNA polymerase II, and consequently affects RNA alternative splicing. CTCF/MAZ double sites are more effective at sequestering cohesin than sites occupied only by CTCF. Furthermore, depletion of CTCF results in preferential loss of CTCF from sites not occupied by MAZ. In an assay for insulation activity like that used for CTCF, binding of MAZ to sites between an enhancer and promoter results in down-regulation of reporter gene expression, supporting a role for MAZ as an insulator protein. Hi-C analysis of the effect of MAZ depletion on genome organization shows that local interactions within topologically associated domains (TADs) are disrupted, as well as contacts that establish the boundaries of individual TADs. We conclude that MAZ augments the action of CTCF in organizing the genome, but also shares properties with CTCF that allow it to act independently.


Assuntos
Fator de Ligação a CCCTC/metabolismo , Proteínas de Ciclo Celular/metabolismo , Proteínas Cromossômicas não Histona/metabolismo , Proteínas de Ligação a DNA/metabolismo , Fatores de Transcrição/metabolismo , Processamento Alternativo , Proteínas de Ligação a DNA/química , Elementos Facilitadores Genéticos , Células HEK293 , Humanos , Células K562 , Regiões Promotoras Genéticas , Ligação Proteica , RNA Polimerase II/metabolismo , Fatores de Transcrição/química , Coesinas
14.
Int J Neurosci ; : 1-7, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38712830

RESUMO

OBJECTIVE: To investigate the effects of dexmedetomidine combined with intraoperative thermal insulation on postoperative cognitive function, cellular immune status and inflammatory markers in patients undergoing radical resection for colorectal cancer. METHODS: Fifty patients who underwent radical resection of colorectal cancer in our hospital from March 2020 to September 2021 were selected and divided into observation group (26 cases with dexmedetomidine combined with intraoperative thermal insulation intervention) and control group (24 cases with conventional anesthesia management). The evaluation measures included the mini-mental state scale (MMSE) score, CD4+ T cell, CD8+ T cell ratio and CD4+/CD8+ ratio, the level of inflammatory markers (IL-6, TNF-α, CRP), and the incidence of postoperative complications. RESULTS: The MMSE score of the observation group was significantly higher than that of the control group on the 3rd day after operation (p < 0.001). After treatment, the proportion of CD4+ T cells, the proportion of CD8+ T cells and the ratio of CD4+/CD8+ in observation group were higher than those in control group (p < 0.01), while the inflammatory markers IL-6, TNF-α and CRP were lower than those in control group (p < 0.01). The incidence of postoperative cognitive dysfunction (POCD) in the observation group (7.69%) was significantly lower than that in the control group (33.33%) (p = 0.010), and the postoperative infection rate was also significantly decreased (p = 0.042). CONCLUSION: Dexmedetomidine combined with intraoperative insulation can significantly improve postoperative cognitive function, maintain immune balance, reduce inflammatory response, and reduce the incidence of POCD and other postoperative complications in patients with radical resection of colorectal cancer.

15.
Sensors (Basel) ; 24(12)2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38931531

RESUMO

The direct-drive selective compliance assembly robot arm (SCARA) is widely used in high-end manufacturing fields, as it omits the mechanical transmission structures and has the advantages of high positioning accuracy and fast movement speed. However, due to the intensifying dynamic coupling problem of structures in the direct-drive SCARA, the permanent magnet synchronous motors (PMSMs) located at the joints will take on nonstationary loads, which causes excessive internal temperature and reduces the lifetime of PMSMs. To address these issues, the lifetime prediction of PMSMs is studied. The kinematic and dynamic models of the SCARA are established to calculate the torque curve required by the PMSM in specific typical motion tasks. Additionally, considering thermal stress as the main factor affecting lifetime, accelerated degradation tests are conducted on insulation material. Then, the reliability function of the PMSM is formulated based on the accelerated degradation model. Based on the parameters and working conditions of the PMSM, the temperature field distribution is obtained through simulation. The maximum temperature is used as the reference temperature to conduct reliability evaluation and lifetime prediction of the PMSM. The research results show that for a typical point-to-point task, the PMSM can run for 102,623 h while achieving the reliability requirement of 0.99.

16.
Sensors (Basel) ; 24(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38339514

RESUMO

A large portion of the pipe infrastructure used in the chemical processing industry is susceptible to corrosion under insulation (CUI). Eddy current-based magnetic sensing is one of the methods that can be used as an early detector of this corrosion. However, the large sensor-to-pipe distances used in this method, due to the presence of insulation, limits the sensitivity to corrosion. This paper will describe the development of instrumentation and methods based on eddy current sensing with thin-film magnetic sensors. In particular, it focuses on the influence of the sensor angle relative to the radial magnetic field. The influence of this parameter on the amplitude of the measured signal was investigated by both finite element simulations and experimental observations. The measured magnetic field was found to be highly sensitive to small changes in sensor angle, with the estimated depth of a defect changing at a rate of 11.2 mm/degree of sensor rotation for small angles. It is also shown that a sensor aligned with the radial direction should be avoided, with an optimal sensor angle between 0.5 and 4 degrees. With the sensor in this angle range, the simulations have shown it should be possible to resolve the depth of corrosion to a resolution of 0.1 mm.

17.
Sensors (Basel) ; 24(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38894356

RESUMO

This paper proposes a new method for recognizing, extracting, and processing Phase-Resolved Partial Discharge (PRPD) patterns from two-dimensional plots to identify specific defect types affecting electrical equipment without human intervention while retaining the principals that make PRPD analysis an effective diagnostic technique. The proposed method does not rely on training complex deep learning algorithms which demand substantial computational resources and extensive datasets that can pose significant hurdles for the application of on-line partial discharge monitoring. Instead, the developed Cosine Cluster Net (CCNet) model, which is an image processing pipeline, can extract and process patterns from any two-dimensional PRPD plot before employing the cosine similarity function to measure the likeness of the patterns to predefined templates of known defect types. The PRPD pattern recognition capabilities of the model were tested using several manually classified PRPD images available in the existing literature. The model consistently produced similarity scores that identified the same defect type as the one from the manual classification. The successful defect type reporting from the initial trials of the CCNet model together with the speed of the identification, which typically does not exceed four seconds, indicates potential for real-time applications.

18.
Emerg Radiol ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39060809

RESUMO

PURPOSE: The use of thermal insulations reduces the risk of hypothermia, therefore decreases the risk of death in trauma victims. The aim of the study was to assess whether thermal insulations cause artifacts, which may hinder the diagnosis of injuries, and how the used thermo-systems alter the radiation dose in polytrauma computed tomography. METHODS: Computed tomography scans were made using the road accident victim body wrapped consecutively with 7 different covers. 14 injury areas were listed and evaluated by 22 radiologists. The radiation dose was measured using a dosimeter placed on the victim in the abdominal area. RESULTS: No significant artifacts in any of the tested covers were observed. The presence of few minor artifacts did not hinder the assessment of injuries. Certain materials increased (up to 19,1%) and some decreased (up to -30,3%) the absorbed radiation dose. CONCLUSIONS: Thermal insulation systems tested in this study do not cause significant artifacts hindering assessment of injuries in CT scans. Concern for artifacts and increased radiation dose should not be a reason to remove patients' thermal insulation during performing trauma CT-scanning.

19.
Sensors (Basel) ; 24(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38931571

RESUMO

During their lifespan, high-voltage (HV) electrical systems are subjected to operating conditions in which electrical, mechanical, thermal and environmental-related stresses occur. These conditions over time lead to unforeseen failures caused by various types of defects. For this reason, there are several technologies for measuring and monitoring the electrical systems, with the aim of minimizing the number of faults. The early detection of defects, preferably in their incipient state, will enable the necessary corrective actions to be taken in order to avoid unforeseen failures. These failures generally lead to human risks and material damage, lack of power supply and significant economic losses. An efficient maintenance technique for the early detection of defects consists of the supervision of the dielectrics status in the installations by means of on-line partial discharge (PD) measurement. Nowadays, there are numerous systems in the market for the measurement of PD in HV installations. The most efficient with a reasonable cost will be those that offer greater security guarantees and the best positioned in the market. Currently, technology developers and users of PD measuring systems face difficulties related to the lack of reference procedures for their complete characterization and to the technical and economic drawback of performing the characterization tests on site or in laboratory installations. To deal with the previous difficulties, in this paper a novel method for the complete and standardized characterization of PD measuring systems is presented. The applicability of this method is mainly adapted for the characterization of systems operating in on-line applications using high-frequency current transformer (HFCT) sensors. For the appropriate application of the method, an associated and necessary scale modular test platform is used. In the test platform, the real on-site measuring conditions of an HV insulated distribution line are simulated in a controlled way. Practical characterizations, showing the convenience and advantages of applying the method using the modular test platform, are also presented.

20.
Sensors (Basel) ; 24(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38474910

RESUMO

Today, online partial discharge (PD) measurements are common practice to assess the condition status of dielectrics in high-voltage (HV) electrical grids. However, when online PD measurements are carried out in electrical facilities, several disadvantages must be considered. Among the most important are high levels of changing electrical noise and interferences, signal phase couplings (cross-talk phenomena), and the simultaneous presence of various defects and difficulties in localizing and identifying them. In the last few decades, various PD-measuring systems have been developed to deal with these inconveniences and try to achieve the adequate supervision of electrical installations. In the state of the art, one of the main problems that electrical companies and technology developers face is the difficulty in characterizing the measuring system's functionalities in laboratory setups or in real-world facilities, where simulated or real defects must be detected. This is mainly due to the complexity and costs that the laboratory setups entail and the fact that the facilities are permanently in service. Furthermore, in the latter scenario, owners cannot assign facilities to carry out the tests, which could cause irreversible damage. Additionally, with the aforementioned installations, a comparison of results over time in various locations is not possible, and noise conditions cannot be controlled to perform the characterizations in a correct way. To deal with the problems indicated, in this article, an affordable scale modular test platform that simulates an HV installation is presented, where real on-site PD measuring conditions are simulated and controlled. In this first development, the HV installation comprises a cable system connected at both ends to a gas-insulated substation (GIS). As the most common acquisition technique in online applications is based on the placement of high-frequency current transformer (HFCT) sensors in the grounding cables of facilities, the test platform is mainly adapted to carry out measurements with this type of sensor. The designed and developed test platform was validated to assess its features and the degree of convergence with a real installation, showing the convenience of its use for the appropriate and standardized characterization of PD-measuring systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA