Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.369
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Ann Surg Oncol ; 31(3): 1812-1822, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38038790

RESUMO

BACKGROUND: Hepatic pedicle clamping (HPC) is frequently utilized during hepatectomy to reduce intraoperative bleeding and diminish the need for intraoperative blood transfusion (IBT). The long-term prognostic implications of HPC following hepatectomy for hepatocellular carcinoma (HCC) remain under debate. This study aims to elucidate the association between HPC and oncologic outcomes after HCC resection, stratified by whether IBT was administered. PATIENTS AND METHODS: Prospectively collected data on patients with HCC who underwent curative resection from a multicenter database was studied. Patients were stratified into two cohorts on the basis of whether IBT was administered. The impact of HPC on long-term overall survival (OS) and recurrence-free survival (RFS) between the two cohorts was assessed by univariable and multivariable Cox regression analyses. RESULTS: Of 3362 patients, 535 received IBT. In the IBT cohort, using or not using HPC showed no significant difference in OS and RFS outcomes (5-year OS and RFS rates 27.9% vs. 24.6% and 13.8% vs. 12.0%, P = 0.810 and 0.530). However, in the non-IBT cohort of 2827 patients, the HPC subgroup demonstrated significantly decreased OS (5-year 45.9% vs. 56.5%, P < 0.001) and RFS (5-year 24.7% vs. 33.3%, P < 0.001) when compared with the subgroup without HPC. Multivariable Cox regression analysis identified HPC as an independent risk factor of OS and RFS [hazard ratios (HR) 1.16 and 1.12, P = 0.024 and 0.044, respectively] among patients who did not receive IBT. CONCLUSIONS: The impact of HPC on the oncological outcomes following hepatectomy for patients with HCC differed significantly whether IBT was administered, and HPC adversely impacted on long-term survival for patients without receiving IBT during hepatectomy.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/cirurgia , Hepatectomia , Neoplasias Hepáticas/cirurgia , Constrição , Estudos Retrospectivos , Prognóstico , Transfusão de Sangue
2.
Osteoporos Int ; 35(3): 543-549, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37921994

RESUMO

Preoperative bone density assessment is necessary to predict screw loosening. The forearm BMD is a useful predictor of BMD-related complications after lumbar operation. Our results show that the forearm BMD is as effective a predictor of screw loosening as the lumbar average HU value. Measurement of the forearm BMD may be a useful adjunct in predicting screw loosening following lumbar fusion. PURPOSE: To determine the relationship between forearm bone mineral density (BMD) and the risk of pedicle screw loosening in patients with lumbar spondylolisthesis. METHODS: We retrospectively evaluated 270 patients who underwent posterior lumbar interbody fusion for lumbar spondylolisthesis. The patients were divided into two groups on the basis of the with or without loose screws: the loosening group and the non-loosening group. The patient's gender, age, BMI, smoking and diabetes histories, and the operative segment were recorded as the basic information. The Hounsfield unit (HU) value for the BMD of the L1-4 lumbar was measured using computed tomography. The patient's distal one-third of the length of the radius and ulna of the non-dominant forearm was chosen as the site for dual-energy X-ray (DXA) bone density testing. RESULTS: The rate of screw loosening was 13% at a minimum 12 months follow-up. Average forearm BMD (0.461 ± 0.1 vs 0.577 ± 0.1, p < 0.001) and mean HU value (L1-4) (121.1 ± 27.3 vs 155.6 ± 32.2, p < 0.001) were lower in the screw loosening group than those in the non-loosening group. In multivariate logistic regression analysis, the forearm BMD (OR 0.840; 95%CI 0.797-0.886) and HU value (L1-4) (OR 0.952; 95%CI 0.935-0.969) were independent risk factor for screw loosening. The area under the curve (AUC) for the forearm BMD and HU value for prediction of pedicle screw loosening was 0.802 and 0.811. The forearm BMD cut-off for predicting pedicle screw loosening was 0.543 (sensitivity, 0.800; specificity, 0.864). CONCLUSIONS: The forearm BMD was an independent risk factor for loosening of the lumbar pedicle screws. The forearm BMD was a valid predictor of pedicle screw loosening in patients undergoing lumbar fusion, as was the CT HU value.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Espondilolistese , Humanos , Densidade Óssea , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Antebraço , Estudos Retrospectivos , Parafusos Pediculares/efeitos adversos , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
3.
Neuroradiology ; 66(5): 855-863, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38453715

RESUMO

PURPOSE: To assess the feasibility and technical accuracy of performing pedicular screw placement combined with vertebroplasty in the radiological setting. METHODS: Patients who underwent combined vertebroplasty and pedicle screw insertion under combined computed tomography and fluoroscopic guidance in 4 interventional radiology centers from 2018 to 2023 were retrospectively assessed. Patient demographics, vertebral lesion type, and procedural data were analyzed. Strict intra-pedicular screw positioning was considered as technical success. Pain score was assessed according to the Visual Analogue Scale before the procedure and in the 1-month follow-up consultation. RESULTS: Fifty-seven patients (38 men and 19 women) with a mean age of 72.8 (SD = 11.4) years underwent a vertebroplasty associated with pedicular screw insertion for the treatment of traumatic fractures (29 patients) and neoplastic disease (28 patients). Screw placement accuracy assessed by post-procedure CT scan was 95.7% (89/93 inserted screws). A total of 93 pedicle screw placements (36 bi-pedicular and 21 unipedicular) in 32 lumbar, 22 thoracic, and 3 cervical levels were analyzed. Mean reported procedure time was 48.8 (SD = 14.7) min and average injected cement volume was 4.4 (SD = 0.9) mL. A mean VAS score decrease of 5 points was observed at 1-month follow-up (7.7, SD = 1.3 versus 2.7, SD = 1.7), p < .001. CONCLUSION: Combining a vertebroplasty and pedicle screw insertion is technically viable in the radiological setting, with a high screw positioning accuracy of 95.7%.


Assuntos
Parafusos Pediculares , Fraturas da Coluna Vertebral , Vertebroplastia , Masculino , Humanos , Feminino , Idoso , Estudos Retrospectivos , Estudos de Viabilidade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Vértebras Lombares/cirurgia , Vertebroplastia/métodos
4.
Pain Med ; 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38944030

RESUMO

BACKGROUND: Neck pain and headaches can arise from the lateral atlanto-axial joint (LAA joint). This pain can be diagnosed with intra-articular injections of local anesthetic. A widely used technique for access to the lateral atlanto-axial joint uses a posterior approach, but this approach can be hazardous because of the proximity of the vertebral artery, the dural sac, and the C2 spinal nerve and dorsal root ganglion. OBJECTIVE: The objective was to describe and test a new technique for accessing the LAA joint that avoids structures that lie behind the joint. INTERVENTIONS: The new technique was described, and tested for tolerance in 10 patients with unilateral suboccipital pain, and tenderness over the LAA joint, along with evidence of LAA joint arthropathy on SPECT CT. The technique requires inserting a needle along a trajectory tangential to the dorsal surface of the C2 lamina. It involves obtaining a declined view of the C2 lamina and C2 pedicle. CONCLUSIONS: In all cases, the C2 pedicle was easily identified and allowed the needle to pass asymptomatically underneath the neurovascular structures behind the joint. The tactile response of the lamina of C2 provided important feedback regarding needle depth caudal to the LAA joint.

5.
Neurosurg Rev ; 47(1): 108, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38456994

RESUMO

This study aimed to assess the effectiveness and safety of robot-assisted versus fluoroscopy-assisted pedicle screw implantation in scoliosis surgery. The study was registered in the PROSPERO (CRD42023471837). Two independent researchers searched PubMed, Web of Science, Cochrane Library, and China National Knowledge Infrastructure. The outcomes included operation time, pedicle screw implantation time, blood loss, number of fluoroscopic, accuracy of pedicle screw position, hospital stays, postoperative hospital stays, Visual Analog Scale (VAS), Japanese Orthopaedic Association (JOA) score, Scoliosis Research Society-22(SRS-22), cobb angle, cobb angle correction rate, sagittal vertical axis (SVA), and complications. Eight papers involving 473 patients met all the criteria. There was no significant difference between the two groups regarding the reduction in operation time. The effect of reducing the pedicle screw implantation time in the RA group was significant (WMD = -1.28; 95% CI: -1.76 to -0.80; P < 0.00001). The effect of reducing the blood loss in the RA group was significant (WMD=-105.57; 95% CI: -206.84 to -4.31; P = 0.04). The effect of reducing the number of fluoroscopic in the RA group was significant (WMD=-5.93; 95% CI: -8.24 to -3.62; P < ). The pedicle screw position of Grade A was significantly more in the RA group according to both the Gertzbein-Robbins scale and the Rampersaud scale. Compared with the FA group, the difference in the hospital stays in the RA group was not statistically significant, but the effect of reducing the postoperative hospital stays in the RA group was significant (WMD = -2.88; 95% CI: -4.13 to -1.63; P < 0.00001). The difference in the VAS, JOA, SRS-22, Cobb angle and Cobb angle correction rate, SVA, and complications between the two groups was not statistically significant. The robot-assisted technique achieved statistically significant results in terms of pedicle screw placement time, blood loss, number of fluoroscopies, accuracy of pedicle screw position, and postoperative hospital stay.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Escoliose , Fusão Vertebral , Humanos , Fluoroscopia/métodos , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Escoliose/cirurgia , Fusão Vertebral/métodos
6.
Neurosurg Rev ; 47(1): 520, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39222163

RESUMO

OBJECTIVE: To propose a screw algorithm and investigate the anatomical feasibilities and clinical outcomes of five distinct fixation methods for C2-3 fused vertebra with high-ridding vertebral arteries (VA) (HRVA) when the C2 pedicle screw placement is unfeasible. METHODS: Thirty surgical patients with congenital C2-3 fusion, HRVA, and atlantoaxial dislocation (AAD) were included. We designed a algorithm for alternative screw implantation into C2-3 fused vertebrae, including C2 pedicle screw with in-out-in (passing VA groove) technique (in-out-in screw), subfacetal screw, translaminar screw, lateral mass screw, C3 pedicle screw. VA diameter and position, C2 and C3 pedicles, superior facets, fused lamina, and fused lateral mass dimensions were evaluated for screw implantation indication. Implant failure, reduction loss, implant placement accuracy were investigated by computed tomography. RESULTS: A total of 5 VAs were identified as distant VAs; a total of 2 VAs were categorized as occlusive VAs. Sufficient dimension of lateral mass and lamina provided the broadest indications for screw implantation, while the distant or occlusive VA provided the most limited indications for in-out-in screw. The indications of five alternative methods ranged from narrowest to widest as follows: in-out-in screw, C3 pedicle screw, subfacetal screw, translaminar screw, lateral mass screw. The translaminar screws and the lateral mass screws increased the probability of implant failure. All patients who received in-out-in screws, C3 pedicle screws, and subfacetal screws achieved fusion. The accuracy ranged from lowest to highest as follows: C3 pedicle screw, lateral mass screw, in-out-in screw, subfacetal screw, translaminar screw. No translaminar screws deviated. CONCLUSIONS: The algorithm proved to be a valuable tool for screw selection in cases of C2-3 fused vertebrae with HRVAs. The subfacetal screw, boasting broad indications, a high fusion rate, and exceptional accuracy, stood as the primary preferred alternative.


Assuntos
Algoritmos , Parafusos Pediculares , Fusão Vertebral , Artéria Vertebral , Humanos , Masculino , Fusão Vertebral/métodos , Feminino , Adulto , Artéria Vertebral/cirurgia , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem , Adolescente , Vértebras Cervicais/cirurgia , Articulação Atlantoaxial/cirurgia , Parafusos Ósseos , Idoso
7.
Eur Spine J ; 33(1): 298-306, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37659047

RESUMO

PURPOSE: The objective of this study was to investigate the optimal entry point and pedicle camber angle for L5 pedicle screws of different canal types. METHODS: CT imaging data were processed by Mimics for simulated pedicle screw placement, and PD (Pedicle diameter), PCA (Pedicle camber angle), LD (Longitudinal distance), TD (Transverse distance), and PBG (Pedicle screw breach grade) were measured. Then they were divided into the Round group and Trefoil group according to the type of spinal canal. When comparing PD, PCA, LD, TD, and PBG, the two sides of the pedicle were compared separately, so they were first divided into the round-type pedicle group and the trefoil-type pedicle group. RESULTS: In the round-type pedicle group (n = 134) and the trefoil-type pedicle group (n = 264), there was no significant difference in PD and LD, but there was a significant difference in PCA between the two groups (t = - 4.072, P < 0.05). A statistically significant difference in the distance of the Magerl point relative to the optimal entry point (t = - 3.792, P < 0.05), and the distance of the Magerl point relative to the optimal entry point was greater in the trefoil-type pedicle group than in the round-type pedicle group. CONCLUSION: The optimal entry point for L5 is more outward than the Magerl point, and the Trefoil spinal canal L5 is more outwardly oriented than the Round spinal canal L5, with a greater angle of abduction during pedicle screw placement.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Estudos Retrospectivos , Fusão Vertebral/métodos , Canal Medular/diagnóstico por imagem , Canal Medular/cirurgia , Tomografia Computadorizada por Raios X
8.
Eur Spine J ; 33(1): 282-288, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37962688

RESUMO

OBJECTIVE: Dorsal instrumentation using pedicle screws is a standard treatment for multiple spinal pathologies, such as trauma, infection, or degenerative indications. Intraoperative three-dimensional (3D) imaging and navigated pedicle screw placement are used at multiple centers. For the present study, we evaluated a new navigation system enabling augmented reality (AR)-supported pedicle screw placement while integrating navigation cameras into the reference array and drill guide. The present study aimed to evaluate its clinical application regarding safety, efficacy, and accuracy. METHODS: A total of 20 patients were operated on between 06/2021 and 01/2022 using the new technique for intraoperative navigation. Intraoperative data with a focus on accuracy and patient safety, including patient outcome, were analyzed. The accuracy of pedicle screw placement was evaluated by intraoperative CT imaging. RESULTS: A median of 8 (4-18) pedicle screws were placed in each case. Percutaneous instrumentation was performed in 14 patients (70%). The duration of pedicle screw placement (duration scan-scan) was 56 ± 26 (30-107) min. Intraoperative screw revision was necessary for 3 of 180 pedicle screws (1.7%). Intraoperatively, no major complications occurred-one case of delay due to software issues and one case of difficult screw placement were reported. CONCLUSION: The current study's results could confirm the use of the present AR-supported system for navigated pedicle screw placement for dorsal instrumentation in clinical routine. It provides a reliable and safe tool for 3D imaging-based pedicle screw placement, only requires a minimal intraoperative setup, and provides new opportunities by integrating AR.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Procedimentos Neurocirúrgicos , Imageamento Tridimensional/métodos , Fusão Vertebral/métodos
9.
Eur Spine J ; 33(1): 314-323, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37964170

RESUMO

OBJECTIVE: Robot-assisted technology has been gradually applied to pedicle screw placement in spinal surgery. This study was designed to detailedly evaluate the learning curve of junior surgeons in robot-assisted spine surgery. METHODS: From December 2020 to February 2022, 199 patients requiring surgical treatment with posterior pedicle screw fixation were prospectively recruited into the study. The patients were randomized to the robot-assisted group (the RA group) or the conventional freehand group (the CF group). Under the senior specialist's supervision, pedicle screws were placed by two junior fellows without prior experience. Cumulative summation (CUSUM) analysis was performed on the learning curve of pedicle screw placement for performing quantitative assessment based on the time of screw insertion. RESULTS: In total, 769 and 788 pedicle screws were placed in the RA and CF groups. Compared with the CF group, the learning duration in the RA group was shorter in the upper thoracic region (57 vs. 70 screws), but longer in the lower thoracic (62 vs. 58 screws) and the lumbosacral region (56 vs. 48 screws). The slope of learning curve was lower in the RA group than in the CF group. The screw accuracy in the RA group was superior to that in the CF group, especially in upper thoracic region (89.4% vs. 76.7%, P < 0.001). This disparity of accuracy became wider in deformity cases. In the upper thoracic region, the mean placement time was 5.34 ± 1.96 min in the RA group and 5.52 ± 2.43 min in the CF groups, while in the lower thoracic and lumbosacral regions, the CF group's mean placement times were statistically shorter. Three screw-related neural complications occurred in the CF group. CONCLUSION: Robot-assisted technique has its advantages in the upper thoracic region and deformity cases, which is easier and safer to insert pedicle screws. The robot-assisted technique allowed a short learning curve for junior surgeons and exhibited consistently excellent results even in the early application period.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Cirurgiões , Humanos , Estudos de Coortes , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Fusão Vertebral/métodos , Estudos Retrospectivos
10.
Eur Spine J ; 33(3): 974-984, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38177834

RESUMO

OBJECTIVE: Conventional freehand methods of pedicle screw placement are associated with significant complications due to close proximity to neural and vascular structures. Recent advances in augmented reality surgical navigation (ARSN) have led to its adoption into spine surgery. However, little is known regarding its overall accuracy. The purpose of this study is to delineate the overall accuracy of ARSN pedicle screw placement across various models. METHODS: A systematic review was conducted of Medline/PubMed, Cochrane and Embase Library databases according to the PRISMA guidelines. Relevant data extracted included reports of pedicle screw placement accuracy and breaches, as defined by the Gertzbein-Robbins classification, in addition to deviation from pre-planned trajectory and entry point. Accuracy was defined as the summation of grade 0 and grade 1 events per the Gertzbein-Robbins classification. RESULTS: Twenty studies reported clinically accurate placed screws. The range of clinically accurate placed screws was 26.3-100%, with 2095 screws (93.1%) being deemed clinically accurate. Furthermore, 5.4% (112/2088) of screws were reported as grade two breaches, 1.6% (33/2088) grade 3 breaches, 3.1% (29/926) medial breaches and 2.3% (21/926) lateral breaches. Mean linear deviation ranged from 1.3 to 5.99 mm, while mean angular/trajectory deviation ranged 1.6°-5.88°. CONCLUSION: The results of this study highlight the overall accuracy of ARSN pedicle screw placement. However, further robust prospective studies are needed to accurately compare to conventional methods of pedicle screw placement.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Cirurgia Assistida por Computador/métodos
11.
Eur Spine J ; 33(8): 2935-2951, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38869649

RESUMO

PURPOSE: To evaluate different patterns of coronal deformity secondary to ankylosing spondylitis (AS), to propose relevant treatment strategies, and to assess efficacy of asymmetrical pedicle subtraction osteotomy (APSO). METHODS: Coronal deformity was defined as coronal Cobb angle over 20º or coronal balance distance (CBD) more than 3 cm. 65 consecutive AS patients with concomitant coronal and sagittal deformity who underwent PSO were included. The average follow-up time was 40.4 months. Radiographic evaluation included coronal Cobb angle and CBD. Furthermore, sagittal parameters were used to assess magnitude and maintenance of kyphosis correction. RESULTS: Based on curve characteristics, coronal deformity caused by AS included four different radiologic patterns: Pattern I: lumbar scoliosis; Pattern II: C-shaped thoracolumbar curve; Pattern III: trunk shift without major curve; Pattern IV: proximal thoracic scoliosis. APSO was performed for patients in Pattern I to III while conventional PSO was applied for patients in Pattern IV. Significant improvement in all the sagittal parameters were noted in 65 patients without obvious correction loss at the last follow-up. Besides, significant and sustained correction of coronal mal-alignment was identified in 59 APSO-treated patients. Rod fracture occurred in four cases and revision surgery was performed for one case. CONCLUSION: According to radiologic manifestations, coronal deformity caused by AS could be categorized into four patterns. APSO proved to be a feasible and effective procedure for correction of Pattern I to III patients. Coronal deformity pattern, apex location, sagittal profile of lumbar spine and preoperative hip function should be considered for osteotomy level selection in APSO.


Assuntos
Cifose , Vértebras Lombares , Osteotomia , Espondilite Anquilosante , Vértebras Torácicas , Humanos , Espondilite Anquilosante/complicações , Espondilite Anquilosante/cirurgia , Espondilite Anquilosante/diagnóstico por imagem , Cifose/cirurgia , Cifose/diagnóstico por imagem , Masculino , Feminino , Adulto , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Osteotomia/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem , Adolescente
12.
Eur Spine J ; 33(6): 2314-2321, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38563986

RESUMO

PURPOSE: To determine if C2 pedicle versus pars screw type predicts change in fusion status, C2 screw loosening, cervical alignment, and patient-reported outcomes measures (PROMs) after C2-T2 posterior cervical decompression and fusion (PDCF). METHODS: All adult patients who underwent C2-T2 PCDF for myelopathy or myeloradiculopathy between 2013-2020 were retrospectively identified. Patients were dichotomized by C2 screw type into bilateral C2 pedicle and bilateral C2 pars screw groups. Preoperative and short- and long-term postoperative radiographic outcomes and PROMs were collected. Univariate and multivariate analysis compared patient factors, fusion status, radiographic measures, and PROMs across groups. RESULTS: A total of 159 patients met the inclusion/exclusion criteria (76 bilateral pedicle screws, 83 bilateral pars screws). Patients in the C2 pars relative to C2 pedicle screw group were on average more likely to have bone morphogenic protein (p = 0.001) and four-millimeter diameter rods utilized intraoperatively (p = 0.033). There were no significant differences in total construct and C2-3 fusion rate, C2 screw loosening, or complication and revision rates between C2 screw groups in univariate and regression analysis. Changes in C2 tilt, C2-3 segmental lordosis, C0-2 Cobb angle, proximal junctional kyphosis, atlanto-dens interval, C1 lamina-occiput distance, C2 sagittal vertical axis, C2-7 lordosis, and PROMs at all follow-up intervals did not vary significantly by C2 screw type. CONCLUSION: There were no significant differences in fusion status, hardware complications, and radiographic and clinical outcomes based on C2 screw type following C2-T2 PCDF. Accordingly, intraoperative usage criteria can be flexible based on patient vertebral artery positioning and surgeon comfort level.


Assuntos
Vértebras Cervicais , Descompressão Cirúrgica , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Feminino , Pessoa de Meia-Idade , Masculino , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Descompressão Cirúrgica/métodos , Descompressão Cirúrgica/instrumentação , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Adulto , Parafusos Pediculares , Doenças da Medula Espinal/cirurgia , Doenças da Medula Espinal/diagnóstico por imagem
13.
Eur Spine J ; 33(6): 2298-2303, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38573386

RESUMO

PURPOSE: Preoperative computed tomography (CT)-based navigation is used for cervical pedicle screw (CPS) insertion to mitigate the risk of spinal cord and vertebral artery injury. In vertebrae with osteosclerosis due to degeneration or other factors, however, probing may not proceed easily, with difficulty creating the CPS insertion hole. This study investigated the impact of osteosclerosis on the accuracy of CPS insertion. METHODS: A total of 138 patients with CPS inserted at the C3-C7 level using preoperative CT navigation were retrospectively analyzed. Pre- and postoperative CT was employed to investigate screw position and Hounsfield unit (HU) values at the lateral mass to evaluate the degree of osteosclerosis in the CPS insertion pathway. RESULTS: Among 561 CPS insertions, the Grade 3 perforation rate was 1.8%, and the Grade 2 or higher perforation rate was 8.0%. When comparing insertions with and without CPS perforation, HU values were significantly higher in the perforation group (578 ± 191 vs. 318 ± 191, p < 0.01). The frequency of CPS insertion into the mid-cervical spine was also significantly greater in the perforation group (68.9% vs. 62.5%, p < 0.01). Logistic regression analysis revealed that a high HU value at the lateral mass (odds ratio 1.09, 95% confidence interval: 1.07-1.11, p < 0.01) was a significant independent factor associated with CPS deviation. CONCLUSIONS: The screw perforation rate of Grade 2 or higher in CPS insertion using preoperative CT-based navigation was 8.0%. Since osteosclerosis was an independent factor related to CPS deviation, additional care may be required during insertion into affected vertebrae.


Assuntos
Vértebras Cervicais , Osteosclerose , Parafusos Pediculares , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto , Osteosclerose/diagnóstico por imagem , Osteosclerose/cirurgia , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Fusão Vertebral/efeitos adversos , Idoso de 80 Anos ou mais , Cuidados Pré-Operatórios/métodos
14.
Eur Spine J ; 33(3): 1069-1080, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38246903

RESUMO

PURPOSE: To compare the clinical outcomes and radiographic outcomes of cortical bone trajectory (CBT) and traditional trajectory (TT) pedicle screw fixation in patients treated with single-level transforaminal lumbar interbody fusion (TLIF). METHODS: This trial included a total of 224 patients with lumbar spine disease who required single-level TLIF surgery. Patients were randomly assigned to the CBT and TT groups at a 1:1 ratio. Demographics and clinical and radiographic data were collected to evaluate the efficacy and safety of CBT and TT screw fixation in TLIF. RESULTS: The baseline characteristic data were similar between the CBT and TT groups. Back and leg pain for both the CBT and TT groups improved significantly from baseline to 24 months postoperatively. The CBT group experienced less pain than the TT group at one week postoperatively. The postoperative radiographic results showed that the accuracy of screw placement was significantly increased in the CBT group compared with the TT group (P < 0.05). The CBT group had a significantly lower rate of FJV than the TT group (P < 0.05). In addition, the rate of fusion and the rate of screw loosening were similar between the CBT and TT groups according to screw loosening criteria. CONCLUSION: This prospective, randomized controlled analysis suggests that clinical outcomes and radiographic characteristics, including fusion rates and caudal screw loosening rates, were comparable between CBT and TT screw fixation. Compared with the TT group, the CBT group showed advantages in the accuracy of screw placement and the FJV rate. CLINICAL TRIALS REGISTRATION: This trial has been registered at the US National Institutes of Health Clinical Trials Registry: NCT03105167.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Dor/etiologia
15.
Eur Spine J ; 33(1): 356-360, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37726431

RESUMO

PURPOSE: To assess clinical, functional and radiographical results of one-level minimally invasive transforaminal interbody fusion with unilateral pedicle screw fixation (UNILIF) in the treatment of stable lumbar degenerative diseases with a minimum of 5 years of follow-up. MATERIAL AND METHOD: From January 2012 to December 2016, clinical and radiological data of patients with degenerative lumbar disease managed by UNILIF were prospectively collected. Patients with a follow-up that ended before 5 years were excluded. SF-12, Oswestry disability index (ODI) and visual analog scale (VAS) were collected preoperatively, at 2 years and at the last follow-up. A full-spine standing radiograph was performed at each follow-up appointment. RESULTS: Mean operative time was 74.7 (± 19) minutes, mean blood loss was 131.1 (± 207) ml and mean follow-up was 7.5 (± 1.7) years. All functional scores and VAS were significantly improved between the preoperative and the 2 years postoperative. Between the 2 years postoperative and the last follow-up ODI and VAS continued to significantly improved. Fusion rate was 98.6% on radiographic analysis at follow-up. CONCLUSION: UNILIF method is a safe and effective surgical strategy. It provides a durable improvement in functional score over 7 years of follow-up with a stable radiological correction over time.


Assuntos
Degeneração do Disco Intervertebral , Parafusos Pediculares , Fusão Vertebral , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Radiografia , Fusão Vertebral/métodos , Resultado do Tratamento , Estudos Retrospectivos
16.
Eur Spine J ; 33(1): 289-297, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37981599

RESUMO

STUDY DESIGN: Retrospective cohort. OBJECTIVE: The purpose of this study is to assess the potential of utilizing the MRI-based vertebral bone quality (VBQ) score as a predictive tool for pedicle screw loosening (PSL) in patients who have undergone pedicle screw fixation and to identify risk factors associated with VBQ scores. METHODS: One hundred and sixteen patients who had undergone pedicle screw fixation between December 2019 and January 2021 and had more than a year of follow-up were divided into two groups of PSL and non-PSL. The radiological and clinical parameters investigated were age, gender, body mass index, the VBQ score, length of fusion and the DXA T-score. RESULTS: Of the 116 patients included in the study, 22 patients developed pedicle screw loosening after surgery (18.97%). VBQ score of PSL group was higher than the non-PSL group (3.61 ± 0.63 vs. 2. 86 ± 0.43, p < 0.001). According to logistic regression, PSL was independently linked with a higher VBQ score (OR = 3.555, 95% confidence interval [1.620-7.802], p < 0.005). The AUC of predicting screw loosening was 0.774 (p < 0.001) for VBQ score, and the best threshold was 3.055 (sensitivity, 81.8%; specificity, 71.3%). High VBQ score was associated with age (r (114) = 0.29, p = 0.002), while it was not negatively correlated with T-scores of each part. CONCLUSION: VBQ score is an independent predictor of pedicle screw loosening, with higher scores indicating a greater risk. Our results showed that older patients and women had higher VBQ scores.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Feminino , Parafusos Pediculares/efeitos adversos , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Imageamento por Ressonância Magnética , Radiografia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
17.
Eur Spine J ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472429

RESUMO

PURPOSE: To test equivalency of deep-learning 3D lumbar spine MRI with "CT-like" contrast to CT for virtual pedicle screw planning and geometric measurements in robotic-navigated spinal surgery. METHODS: Between December 2021 and June 2022, 16 patients referred for spinal fusion and decompression surgery with pre-operative CT and 3D MRI were retrospectively assessed. Pedicle screws were virtually placed on lumbar (L1-L5) and sacral (S1) vertebrae by three spine surgeons, and metrics (lateral deviation, axial/sagittal angles) were collected. Vertebral body length/width (VL/VW) and pedicle height/width (PH/PW) were measured at L1-L5 by three radiologists. Analysis included equivalency testing using the 95% confidence interval (CI), a margin of ± 1 mm (± 2.08° for angles), and intra-class correlation coefficients (ICCs). RESULTS: Across all vertebral levels, both combined and separately, equivalency between CT and MRI was proven for all pedicle screw metrics and geometric measurements, except for VL at L1 (mean difference: - 0.64 mm; [95%CI - 1.05, - 0.24]), L2 (- 0.65 mm; [95%CI - 1.11, - 0.20]), and L4 (- 0.78 mm; [95%CI - 1.11, - 0.46]). Inter- and intra-rater ICC for screw metrics across all vertebral levels combined ranged from 0.68 to 0.91 and 0.89-0.98 for CT, and from 0.62 to 0.92 and 0.81-0.97 for MRI, respectively. Inter- and intra-rater ICC for geometric measurements ranged from 0.60 to 0.95 and 0.84-0.97 for CT, and 0.61-0.95 and 0.93-0.98 for MRI, respectively. CONCLUSION: Deep-learning 3D MRI facilitates equivalent virtual pedicle screw placements and geometric assessments for most lumbar vertebrae, with the exception of vertebral body length at L1, L2, and L4, compared to CT for pre-operative planning in patients considered for robotic-navigated spine surgery.

18.
Eur Spine J ; 33(2): 706-712, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38233628

RESUMO

PURPOSE: Since childhood exposure to radiation has been demonstrated to increase cancer risk with increase in radiation dose, reduced radiation exposure during computed tomography (CT) evaluation is desired for adolescent idiopathic scoliosis (AIS). Therefore, this retrospective study aimed to investigate the radiation dose of dual-source CT using a spectral shaping technique and the accuracy of the thoracic pedicle screw (TPS) placement for posterior spinal fusion (PSF) in patients with AIS. METHODS: Fifty-nine female patients with thoracic AIS who underwent PSF using CT-guided TPSs were included and divided into two groups comprised of 23 patients who underwent dual-source CT (DSCT) with a tin filter (DSCT group) and 36 who underwent conventional multislice CT (MSCT group). We assessed the CT radiation dose using the CT dose index (CTDIvol), effective dose (ED), and accuracy of TPS insertion according to the established Neo's classification. RESULTS: The DSCT and MSCT groups differed significantly (p < 0.001) in the mean CTDIvol (0.76 vs. 3.31 mGy, respectively) and ED (0.77 vs. 3.47 mSv, respectively). Although the correction rate of the main thoracic curve in the DSCT group was lower (65.7% vs. 71.2%) (p = 0.0126), the TPS accuracy (Grades 0-1) was similar in both groups (381 screws [88.8%] vs. 600 screws [88.4%], respectively) (p = 0.8133). No patient required replacement of malpositioned screws. CONCLUSION: Spectral shaping DSCT with a tube-based tin filter allowed a 75% radiation dose reduction while achieving TPS insertion accuracy similar to procedures based on conventional CT without spectral shaping.


Assuntos
Escoliose , Humanos , Adolescente , Feminino , Criança , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Estanho , Tomografia Computadorizada por Raios X , Ácido Dioctil Sulfossuccínico , Fenolftaleína
19.
Eur Spine J ; 33(8): 3275-3283, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38858266

RESUMO

BACKGROUND: Osteoporotic vertebral compression fractures (OVCF) caused by osteoporosis is a common clinical fracture type. There are many surgical treatment options for OVCF, but there is a lack of comparison among different options. Therefore, we counted a total of 104 cases of OVCF operations with different surgical plans, followed up the patients, and compared the surgical outcome indications before, after and during the follow-up. METHOD: 104 patients who underwent posterior osteotomy (Modified PSO, SPO, PSO, VCR) and kyphosis correction surgery at our hospital between April 2006 and August 2021 with a minimum follow-up period of 24 months were included. All cases were injuries induced by a fall incurred while standing or lifting heavy objects without high-energy trauma. The mean CT value was 71 HU, which was below 110 HU, indicating severe osteoporosis. The indications for surgery included gait disturbance due to severe pain with pseudarthrosis, increased kyphotic angle, and progressive neurological symptoms. Pre- and postoperative CL, TLK, TK, PrTK, TKmax, GK, LL, PI, SS, PT, SVA, TPA, were investigated radiologically. Additionally, We evaluated estimated blood loss, surgical time and perioperative symptom. RESULT: The results show, after operation, TLK (37.32 ± 10.61° vs. 11.01 ± 8.06°, P < 0.001), TK (35.42 ± 17.64° vs. 25.62 ± 12.24°, P < 0.001), TKmax (49.71 ± 16.32° vs. 24.12 ± 13.34°, P < 0.001), SVA (44.91 ± 48.67 vs. 23.52 ± 30.21, P = 0.013), CL (20.23 ± 13.21° vs. 11.45 ± 9.85°, P = 0.024) and TPA (27.44 ± 12.76° vs. 13.91 ± 9.24°, P = 0.009) were improved significantly in modified Pedicle subtraction osteotomy (mPSO) after operation. During follow-up, TLK (37.32 ± 10.61° vs. 13.88 ± 10.02°, P < 0.001) and TKmax (49.71 ± 16.32° vs. 24.12 ± 13.34°, P < 0.001) were improved significantly in Modified PSO group. In additon, estimated blood loss (790.0 ± 552.2 ml vs. 987.0 ± 638.5 ml, P = 0.038), time of operation (244.1 ± 63.0 min vs. 292.4 ± 87.6 min, P = 0.025) were favorable in Modified PSO group compared to control group. CONCLUSION: To conclude, mPSO could acquire a favorable degree of kyphosis correction as well as fewer follow-up complications. Compared with other surgical methods, it also has the advantages of less surgical trauma and shorter operation time. It can be an effective solution for the treatment of OVCF.


Assuntos
Fraturas por Compressão , Fraturas por Osteoporose , Osteotomia , Fraturas da Coluna Vertebral , Humanos , Fraturas por Compressão/cirurgia , Feminino , Masculino , Osteotomia/métodos , Idoso , Fraturas por Osteoporose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Resultado do Tratamento , Cifose/cirurgia , Cifose/etiologia
20.
Eur Spine J ; 33(5): 2031-2042, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548932

RESUMO

PURPOSE: To assess whether the intention to intraoperatively reposition pedicle screws differs when spine surgeons evaluate the same screws with 2D imaging or 3D imaging. METHODS: In this online survey study, 21 spine surgeons evaluated eight pedicle screws from patients who had undergone posterior spinal fixation. In a simulated intraoperative setting, surgeons had to decide if they would reposition a marked pedicle screw based on its position in the provided radiologic imaging. The eight assessed pedicle screws varied in radiologic position, including two screws positioned within the pedicle, two breaching the pedicle cortex < 2 mm, two breaching the pedicle cortex 2-4 mm, and two positioned completely outside the pedicle. Surgeons assessed each pedicle screw twice without knowing and in random order: once with a scrollable three-dimensional (3D) image and once with two oblique fluoroscopic two-dimensional (2D) images. RESULTS: Almost all surgeons (19/21) intended to reposition more pedicle screws based on 3D imaging than on 2D imaging, with a mean number of pedicle screws to be repositioned of, respectively, 4.1 (± 1.3) and 2.0 (± 1.3; p < 0.001). Surgeons intended to reposition two screws placed completely outside the pedicle, one breaching 2-4mm, and one breaching < 2 mm more often based on 3D imaging. CONCLUSION: When provided with 3D imaging, spine surgeons not only intend to intraoperatively reposition pedicle screws at risk of causing postoperative complications more often but also screws with acceptable positions. This study highlights the potential of intraoperative 3D imaging as well as the need for consensus on how to act on intraoperative 3D information.


Assuntos
Parafusos Pediculares , Humanos , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Coluna Vertebral/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Imageamento Tridimensional/métodos , Inquéritos e Questionários , Cirurgiões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA