Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.544
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Gastroenterology ; 166(6): 1020-1055, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38763697

RESUMO

BACKGROUND & AIMS: Barrett's esophagus (BE) is the precursor to esophageal adenocarcinoma (EAC). Endoscopic eradication therapy (EET) can be effective in eradicating BE and related neoplasia and has greater risk of harms and resource use than surveillance endoscopy. This clinical practice guideline aims to inform clinicians and patients by providing evidence-based practice recommendations for the use of EET in BE and related neoplasia. METHODS: The Grading of Recommendations Assessment, Development and Evaluation framework was used to assess evidence and make recommendations. The panel prioritized clinical questions and outcomes according to their importance for clinicians and patients, conducted an evidence review, and used the Evidence-to-Decision Framework to develop recommendations regarding the use of EET in patients with BE under the following scenarios: presence of (1) high-grade dysplasia, (2) low-grade dysplasia, (3) no dysplasia, and (4) choice of stepwise endoscopic mucosal resection (EMR) or focal EMR plus ablation, and (5) endoscopic submucosal dissection vs EMR. Clinical recommendations were based on the balance between desirable and undesirable effects, patient values, costs, and health equity considerations. RESULTS: The panel agreed on 5 recommendations for the use of EET in BE and related neoplasia. Based on the available evidence, the panel made a strong recommendation in favor of EET in patients with BE high-grade dysplasia and conditional recommendation against EET in BE without dysplasia. The panel made a conditional recommendation in favor of EET in BE low-grade dysplasia; patients with BE low-grade dysplasia who place a higher value on the potential harms and lower value on the benefits (which are uncertain) regarding reduction of esophageal cancer mortality could reasonably select surveillance endoscopy. In patients with visible lesions, a conditional recommendation was made in favor of focal EMR plus ablation over stepwise EMR. In patients with visible neoplastic lesions undergoing resection, the use of either endoscopic mucosal resection or endoscopic submucosal dissection was suggested based on lesion characteristics. CONCLUSIONS: This document provides a comprehensive outline of the indications for EET in the management of BE and related neoplasia. Guidance is also provided regarding the considerations surrounding implementation of EET. Providers should engage in shared decision making based on patient preferences. Limitations and gaps in the evidence are highlighted to guide future research opportunities.


Assuntos
Adenocarcinoma , Esôfago de Barrett , Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Esofagoscopia , Esôfago de Barrett/cirurgia , Esôfago de Barrett/patologia , Humanos , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/patologia , Ressecção Endoscópica de Mucosa/efeitos adversos , Esofagoscopia/normas , Esofagoscopia/efeitos adversos , Adenocarcinoma/cirurgia , Adenocarcinoma/patologia , Gastroenterologia/normas , Medicina Baseada em Evidências/normas , Resultado do Tratamento , Tomada de Decisão Clínica , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/normas
2.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
3.
Small ; : e2311244, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898764

RESUMO

Radiofrequency ablation (RFA) is one of the most common minimally invasive techniques for the treatment of solid tumors, but residual malignant tissues or small satellite lesions after insufficient RFA (iRFA) are difficult to remove, often leading to metastasis and recurrence. Here, Fe-TPZ nanoparticles are designed by metal ion and (TPZ) ligand complexation for synergistic enhancement of RFA residual tumor therapy. Fe-TPZ nanoparticles are cleaved in the acidic microenvironment of the tumor to generate Fe2+ and TPZ. TPZ, an anoxia-dependent drug, is activated in residual tumors and generates free radicals to cause tumor cell death. Elevated Fe2+ undergoes a redox reaction with glutathione (GSH), inducing a strong Fenton effect and promoting the production of the highly toxic hydroxyl radical (•OH). In addition, the ROS/GSH imbalance induced by this treatment promotes immunogenic cell death (ICD), which triggers the release of damage-associated molecular patterns, macrophage polarization, and lymphocyte infiltration, thus triggering a systemic antitumor immune response and noteworthy prevention of tumor metastasis. Overall, this integrated treatment program driven by multiple microenvironment-dependent pathways overcomes the limitations of the RFA monotherapy approach and thus improves tumor prognosis. Furthermore, these findings aim to provide new research ideas for regulating the tumor immune microenvironment.

4.
Histochem Cell Biol ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997526

RESUMO

Long-term radiofrequency radiation (RFR) exposure, which adversely affects organisms, deteriorates testicular functions. Misfolding or unfolding protein accumulation in the endoplasmic reticulum (ER) initiates an intracellular reaction known as ER stress (ERS), which activates the unfolded protein response (UPR) for proteostasis. Since both RFR exposure and ERS can cause male infertility, we hypothesized that RFR exposure causes ERS to adversely affect testicular functions in rats. To investigate role of ERS in mediating RFR effects on rat testis, we established five experimental groups in male rats: control, short-term 2100-megahertz (MHz) RFR (1-week), short-term sham (sham/1-week), long-term 2100-MHz RFR (10-week), and long-term sham (sham/10-week). ERS markers Grp78 and phosphorylated PERK (p-Perk) levels and ERS-related apoptosis markers Chop and caspase 12 were investigated by immunohistochemistry, immunoblotting, and quantitative real-time polymerase chain reaction (qPCR). Long-term RFR exposure increased Grp78, p-Perk, and Chop levels, while short-term RFR exposure elevated Chop and caspase 12 levels. Chop expression was not observed in spermatogonia and primary spermatocytes, which may protect spermatogonia and primary spermatocytes against RFR-induced ERS-mediated apoptosis, thereby allowing transmission of genetic material to next generations. While short and long-term RFR exposures trigger ERS and ERS-related apoptotic pathways, further functional analyses are needed to elucidate whether this RFR-induced apoptosis has long-term male infertility effects.

5.
Magn Reson Med ; 92(4): 1768-1787, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38872443

RESUMO

PURPOSE: To introduce a simple system exploitation with the potential to turn MRI scanners into general-purpose radiofrequency (RF) motion monitoring systems. METHODS: Inspired by Pilot Tone (PT), this work proposes Beat Pilot Tone (BPT), in which two or more RF tones at arbitrary frequencies are transmitted continuously during the scan. These tones create motion-modulated standing wave patterns that are sensed by the receiver coil array, incidentally mixed by intermodulation in the receiver chain, and digitized simultaneously with the MRI data. BPT can operate at almost any frequency as long as the intermodulation products lie within the bandwidth of the receivers. BPT's mechanism is explained in electromagnetic simulations and validated experimentally. RESULTS: Phantom and volunteer experiments over a range of transmit frequencies suggest that BPT may offer frequency-dependent sensitivity to motion. Using a semi-flexible anterior receiver array, BPT appears to sense cardiac-induced body vibrations at microwave frequencies ( ≥ $$ \ge $$ 1.2 GHz). At lower frequencies, it exhibits a similar cardiac signal shape to PT, likely due to blood volume changes. Other volunteer experiments with respiratory, bulk, and head motion show that BPT can achieve greater sensitivity to motion than PT and greater separability between motion types. Basic multiple-input multiple-output ( 4 × 22 $$ 4\times 22 $$ MIMO) operation with simultaneous PT and BPT in head motion is demonstrated using two transmit antennas and a 22-channel head-neck coil. CONCLUSION: BPT may offer a rich source of motion information that is frequency-dependent, simultaneous, and complementary to PT and the MRI exam.


Assuntos
Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ondas de Rádio , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Desenho de Equipamento , Movimento/fisiologia , Reprodutibilidade dos Testes , Simulação por Computador , Algoritmos , Cabeça/diagnóstico por imagem
6.
Magn Reson Med ; 91(4): 1723-1734, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38084471

RESUMO

PURPOSE: Testing an RF coil prototype on subjects involves laborious verifications to ensure its safety. In particular, it requires preliminary electromagnetic simulations and their validations on phantoms to accurately predict the specific absorption rate (SAR). For coil design validation with a simpler safety procedure, the restricted SAR (rS) mode is proposed, enabling representative first experiments in vivo. The goal of the developed approach is to accelerate the transition of a custom coil system from prototype to clinical use. METHODS: The restricted specific absorption rate (SAR) (rS) mode imposes a radical limitation on the transmitted RF power based on a worst-case scenario of local RF power absorption. The limitations used are independent of the SAR spatial distribution, making this approach unconditionally safe. The developed rS protocol contains the sequences required for coil evaluation and satisfies the imposed rS conditions. It provides a quantitative characterization of the coil transmission and reception profiles and a qualitative evaluation of the anatomical images. Protocol validation was performed on commercial and pre-industrial prototype coils on a small cohort of healthy volunteers. RESULTS: The proposed rS protocol enables coil evaluation within an acquisition time compatible with common clinical protocol duration. The total time of all evaluation steps does not exceed 17 min. At the same time, the global SAR remains 100 times less than the International Electrotechnical Commission safety limit for played sequences. CONCLUSION: The rS protocol allows characterizing and comparing coil prototypes on volunteers without extensive electromagnetic calculations and phantom validations in an unconditionally safe way.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
7.
Magn Reson Med ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136249

RESUMO

PURPOSE: Advancing the development of 7 T MRI for spinal cord imaging is crucial for the enhanced diagnosis and monitoring of various neurodegenerative diseases and traumas. However, a significant challenge at this field strength is the transmit field inhomogeneity. Such inhomogeneity is particularly problematic for imaging the small, deep anatomical structures of the cervical spinal cord, as it can cause uneven signal intensity and elevate the local specific absorption ratio, compromising image quality. This multisite study explores several RF shimming techniques in the cervical spinal cord. METHODS: Data were collected from 5 participants between two 7 T sites with a custom 8Tx/20Rx parallel transmission coil. We explored two radiofrequency (RF) shimming approaches from an MRI vendor and four from an open-source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord. RESULTS: The circularly polarized (CP), coefficient of variation (CoV), and specific absorption rate (SAR) efficiency shim modes showed the highest B1 + efficiency, and the vendor-based "patient" and "volume" modes showed the lowest B1 + efficiency. The coefficient of variation method produced the highest CSF/spinal cord contrast on T2*-weighted scans (ratio of 1.27 ± 0.03), and the lowest variation of that contrast along the superior-inferior axis. CONCLUSION: The study's findings highlight the potential of RF shimming to advance 7 T MRI's clinical utility for central nervous system imaging by enabling more homogenous and efficient spinal cord imaging. Additionally, the research incorporates a reproducible Jupyter Notebook, enhancing the study's transparency and facilitating peer verification.

8.
J Cardiovasc Electrophysiol ; 35(3): 511-515, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38225537

RESUMO

INTRODUCTION: Atrial fibrillation and atrial flutter originating from the donor s heart is a commonly reported complication post heart transplant. Atrial tachyarrhythmia originating from the recipient s heart, propagated through recipient-to-donor connections, is rare with only few cases reported in the literature; most reported cases from our review occur years post-transplant. CASE: A 47-year-old male presented with atrial tachycardia 6 months post heart transplant. Electrophysiologic study demonstrated atrial fibrillation originating from native heart and propagated through atrio-atrial connections to the donor heart. This arrhythmia was successfully terminated with radiofrequency ablation. CONCLUSION: Atrio-atrial connection between recipient and donor can form as early as a few months post heart transplant. Radiofrequency ablation appears to be an effective treatment for atrial fibrillation propagated through donor-to-recipient connections.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Transplante de Coração , Masculino , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Transplante de Coração/efeitos adversos , Ablação por Cateter/efeitos adversos , Doadores de Tecidos , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/cirurgia
9.
J Cardiovasc Electrophysiol ; 35(4): 625-638, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38174841

RESUMO

INTRODUCTION: The utility of ablation index (AI) to guide ventricular tachycardia (VT) ablation in patients with structural heart disease is unknown. The aim of this study was to assess procedural characteristics and clinical outcomes achieved using AI-guided strategy (target value 550) or conventional non-AI-guided parameters in patients undergoing scar-related VT ablation. METHODS: Consecutive patients (n = 103) undergoing initial VT ablation at a single center from 2017 to 2022 were evaluated. Patient groups were 1:1 propensity-matched for baseline characteristics. Single lesion characteristics for all 4707 lesions in the matched cohort (n = 74) were analyzed. The impact of ablation characteristics was assessed by linear regression and clinical outcomes were evaluated by Cox proportional hazard model. RESULTS: After propensity-matching, baseline characteristics were well-balanced between AI (n = 37) and non-AI (n = 37) groups. Lesion sets were similar (scar homogenization [41% vs. 27%; p = .34], scar dechanneling [19% vs. 8%; p = .18], core isolation [5% vs. 11%; p = .4], linear and elimination late potentials/local abnormal ventricular activities [35% vs. 44%; p = .48], epicardial mapping/ablation [11% vs. 14%; p = .73]). AI-guided strategy had 21% lower procedure duration (-47.27 min, 95% confidence interval [CI] [-81.613, -12.928]; p = .008), 49% lower radiofrequency time per lesion (-13.707 s, 95% CI [-17.86, -9.555]; p < .001), 21% lower volume of fluid administered (1664 cc [1127, 2209] vs. 2126 cc [1750, 2593]; p = .005). Total radiofrequency duration (-339 s [-24%], 95%CI [-776, 62]; p = .09) and steam pops (-155.6%, 95% CI [19.8%, -330.9%]; p = .08) were nonsignificantly lower in the AI group. Acute procedural success (95% vs. 89%; p = .7) and VT recurrence (0.97, 95% CI [0.42-2.2]; p = .93) were similar for both groups. Lesion analysis (n = 4707) demonstrated a plateau in the magnitude of impedance drops once reaching an AI of 550-600. CONCLUSION: In this pilot study, an AI-guided ablation strategy for scar-related VT resulted in shorter procedure time and average radiofrequency time per lesion with similar acute procedural and intermediate-term clinical outcomes to a non-AI-guided approach utilizing traditional ablation parameters.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Projetos Piloto , Cicatriz/diagnóstico , Cicatriz/etiologia , Cicatriz/cirurgia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
Artigo em Inglês | MEDLINE | ID: mdl-39049491

RESUMO

BACKGROUND: Maintaining an adequate temperature at the target site is essential for effective ablation. We hypothesized that a tissue temperature-controlled (T-Con) catheter for cavotricuspid isthmus (CTI) ablation could improve the procedural ablation parameters. PURPOSE: To evaluate the efficacy and safety of the T-Con (DiamondTemp™) catheter for CTI ablation compared with non-irrigation (Non-Irri) and irrigation (Irri) catheters. METHODS: We analyzed 150 patients who underwent prophylactic CTI ablation combined with pulmonary vein isolation. The Non-Irri, Irri, and T-Con catheter groups comprised 50 patients each, and the ablation procedural parameters and complications were compared between these groups. RESULTS: There were no significant differences in clinical background characteristics among the three groups. The Kruskal-Wallis and post hoc tests demonstrated that the T-Con group showed the lowest total radiofrequency energy delivery time among the three groups (median [25 and 75 percentiles]: 340 [209, 357], 147 [100, 199], and 83 [61, 109] s, respectively in the Non-Irri, Irri, and T-Con groups; T-Con versus Non-Irri, p < .01; T-Con versus Irri, p < .01). The total procedural time and acute reconnection rate in the T-Con group (264 s and 4%, respectively) were lower than those in the Non-Irri group (438 s and 24%) but were similar to those in the Irri group (268 s and 6%). No significant complications were observed in any group. CONCLUSIONS: The T-Con catheter achieved a short energy delivery time and a low acute reconnection rate, indicating its potential as an alternative catheter for CTI ablation.

11.
J Cardiovasc Electrophysiol ; 35(3): 461-468, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38282308

RESUMO

OBJECTIVE: To evaluate the progression of electrophysiological phenomena in atrial fibrillation (AF) and elucidate the association between the left atrial conduction velocity (LACV) and AF recurrence after pulmonary vein isolation. METHODS: A total of 188 AF patients (121 paroxysmal AF and 67 persistent AF) who underwent PVI for the first time were enrolled in this prospective study. The left atrium was mapped using a 20-pole electrode catheter combined with the CARTO3 system. The conduction distances and conduction times of the left atrium from the Bachmann bundle area to the mitral isthmus were calculated. Anterior, posterior, and septal LACV were calculated as conduction distance divided by conduction time. RESULTS: The anterior, posterior, and septal LACVs in the AF recurrence group were slower than those in the nonrecurrence group (anterior: 0.807 [0.766, 0.848] and 1.048 [1.000, 1.093] m/s, p < .05; posterior: 1.037 [0.991, 1.084] vs. 1.315 [1.249, 1.380] m/s, p < .05; septal: 0.904 [0.862, 0.946] vs. 1.163 [1.107, 1.219] m/s, p < .05). The best cut-off value of anterior LACV for predicting AF recurrence was 0.887 m/s (sensitivity 73.9% and specificity 76.5%). Multivariate analysis showed slow anterior LACV <0.887 m/s was an independent predictor of AF recurrence with an adjusted odds ratio of 1.42 (1.04, 1.94). CONCLUSIONS: Slowing conduction velocity is a predictor of AF recurrence after pulmonary vein isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Átrios do Coração , Veias Pulmonares/cirurgia , Recidiva
12.
Artigo em Inglês | MEDLINE | ID: mdl-39188036

RESUMO

BACKGROUND: Safety data of the latest radiofrequency (RF) technologies during atrial fibrillation (AF) ablation in real-world clinical practice are limited. OBJECTIVES: We sought to evaluate the acute procedural safety of the four latest ablation catheters commonly used for AF ablation. METHODS: A total of 3957 AF ablation procedures performed between January 2022 and December 2023 at 20 centers with either the THERMOCOOL SMARTTOUCH SF (STSF), TactiCath (TC), QDOT Micro (QDM), or TactiFlex (TF) were retrospectively analyzed. RESULTS: In total, QDM, STSF, TF, and TC were used in 343 (8.7%), 1793 (45.3%), 1121 (28.4%), and 700(17.7%) procedures. Among 2406 index procedures, electrical pulmonary vein isolations were successfully achieved in 99.5%. Despite similar total procedure times in the four groups, the total fluoroscopic time was significantly shorter for QDM/STSF with CARTO than TF/TC with EnSite (18.7 ± 14 vs. 27.6 ± 20.6 min, p < .001) and longest in the TF group. The incidence of cardiac tamponade was 0.7% (0.5% and 0.9% during index and redo procedures, 0.8% and 0.3% for paroxysmal and non-paroxysmal AF) and was significantly lower for QDM/STSF than TF/TC (0.2% vs. 1.1%, p = .008) and highest in the TF group. The incidence of cardiac tamponade was higher for TF than TC and STSF than QDM. In the multivariate analysis, TF/TC with EnSite was a significant independent predictor of cardiac tamponade during both the index (odds ratio [OR] = 4.8, 95% confidence interval [CI] = 1.3-17.5, p = .02) and all procedures (OR = 3.0, 95% CI = 1.3-7.2, p = .01). CONCLUSIONS: The incidence of cardiac tamponade and the fluoroscopic time during AF ablation significantly differed among the latest RF catheters and mapping systems in real-world clinical practice.

13.
J Cardiovasc Electrophysiol ; 35(8): 1561-1569, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38818534

RESUMO

INTRODUCTION: Esophageal safety following radiofrequency (RF) left atrial (LA) linear ablation has not been established. To determine the esophageal safety profile of LA linear RF lesions, we performed systematic esophagogastroduodenoscopy in all patients with intraesophageal temperature rise (ITR) ≥ 38.5°C. METHODS AND RESULTS: Between December 2021 and July 2023, a total of 200 consecutive patients with atrial tachyarrhythmia (ATA) underwent linear ablation with posterior dome (roof or floor) or posterior mitral isthmus line transection. Patients with ITR ≥ 38.5°C were scheduled for esophageal endoscopy ~3 weeks after ablation. Patient and ATA characteristics, procedural parameters, endoscopy findings and ablation lesion data were collected and analyzed. One hundred thirty-three out of 200 (67%) patients showed ITR ≥ 38.5°C during LA linear ablation. ITR (with maximal temperature of 45.7°C) was more frequently observed during floor line ablation (82% of cases). ITR was less observed during roof line ablation (34%) and posterior mitral isthmus ablation (4%). Endoscopy, performed in 115 patients after 24 ± 10 days, showed esophageal ulceration in four patients (two patients Kansas City classification [KCC] 2a and two patients KCC 2b). No patient showed esophageal perforation or fistula. CONCLUSION: Temperature rise during LA linear ablation is frequent and ulceration risk exists, particularly when floor line is performed. Safety measures are needed to avoid potential severe complications like esophageal perforation and fistula.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Úlcera , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Úlcera/diagnóstico por imagem , Úlcera/etiologia , Úlcera/diagnóstico , Resultado do Tratamento , Idoso , Medição de Risco , Fatores de Risco , Ablação por Cateter/efeitos adversos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Doenças do Esôfago/etiologia , Doenças do Esôfago/diagnóstico , Fatores de Tempo , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Endoscopia do Sistema Digestório/efeitos adversos , Estudos Retrospectivos , Esôfago/lesões
14.
J Cardiovasc Electrophysiol ; 35(3): 547-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37855621

RESUMO

The QDOT MICRO™ Catheter is a novel open-irrigated contact force-sensing radiofrequency ablation catheter. It offers very high-power short-duration (vHPSD) ablation with 90 W for 4 s to improve safety and efficacy of catheter ablation procedures. Although the QDOT MICRO™ Catheter was mainly designed for pulmonary vein isolation (PVI) its versatility to treat atrial fibrillation (AF) and other types of arrhythmias was recently evaluated by the FAST and FURIOUS study series and other studies and will be presented in this article. Available study and registry data as well as case reports concerning utilization of the QDOT MICRO™ Catheter for the treatment of cardiac arrhythmias including AF, focal and macroreentry atrial tachycardia, typical atrial flutter by cavotricuspid isthmus block, premature ventricular contractions, and accessory pathways were reviewed and summarized. In summary, the QDOT MICRO™ Catheter showed safety and efficacy for PVI and is able to treat also other types of arrhythmias as is was recently evaluated by case reports and the FAST and FURIOUS studies.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
15.
J Cardiovasc Electrophysiol ; 35(2): 317-327, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105426

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS: We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS: Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION: Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Creatina Quinase Forma MB , Inflamação/diagnóstico , Veias Pulmonares/cirurgia , Troponina T , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Recidiva
16.
Artigo em Inglês | MEDLINE | ID: mdl-38992888

RESUMO

BACKGROUND: The impact of sodium-glucose cotransporter 2 (SGLT2) inhibitors on the postoperative recurrence of atrial fibrillation (AF) in patients with persistent AF undergoing an initial radiofrequency ablation is not yet established. The objective of this study is to assess the impact of SGLT2 inhibitors on the recurrence of AF after radiofrequency ablation in patients with type 2 diabetes complicated persistent AF. METHODS: A total of 182 patients with type 2 diabetes and persistent AF, who underwent their first radiofrequency ablation for AF at our center, were enrolled and divided into two groups: the SGLT2 inhibitor group and the non-SGLT2 inhibitor group. The main outcome of the follow-up was the postoperative recurrence of AF. RESULTS: A total of 49 participants experienced AF recurrence. The use of SGLT2 inhibitors in patients with type 2 diabetes who underwent AF ablation was associated with a significantly lower risk of AF recurrence (adjusted hazard ratio: 0.65; 95% confidence interval: 0.28-0.83; p < .01). CONCLUSIONS: The use of SGLT2 inhibitors is associated with a decreased risk of arrhythmia recurrence after AF ablation in patients with type 2 diabetes complicated with persistent AF.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38956821

RESUMO

BACKGROUND: Despite advances in efficacy and safety of pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence after PVI remains common. PV-reconnection is the main finding during repeat PVI procedures performed to treat recurrent AF. OBJECTIVE: To analyze pulmonary vein (PV) reconnection patterns during repeat ablation procedures in a large cohort of consecutive patients undergoing radio frequency or cryoballoon-based PVI. METHODS: Retrospective analysis of PV-reconnection patterns and analysis of re-ablation strategies in consecutive index RF- and CB-based PVI and their respective re-ablation procedures during concomitant usage of both energy sources at a single high-volume center in Germany. RESULTS: A total of 610 first (06/2015-10/2022) and 133 s (01/2016-11/2022) repeat ablation procedures after 363 (60%) RF- and 247 (40%) CB-based index PVIs between 01/2015 and 12/2021 were analyzed. PV-reconnection was found in 509/610 (83%) patients at first and 74/133 (56%) patients at second repeat procedure. 465 of 968 (48%) initially via CB isolated PVs were reconnected at first re-ablation but 796 of 1422 initially RF-isolated PV (56%) were reconnected (OR: 0.73 [95% CI: 0.62-0.86]; p < .001). This was driven by fewer reconnections of the left PVs (LSPV: OR: 0.60 [95% CI: 0.42-0.86]; p = .005 and LSPV: 0.67 [0.47-0.95]; p = .026). PV-reconnection was more likely after longer, RF-based index PVI and in older females. Repeat procedures were shorter after CB-compared to after RF-PVI. CONCLUSIONS: Reconnection remains the most common reason for repeat AF ablation procedures after PVI. Our data suggest to preferentially use of the cryoballoon during index PVI, especially in older women.

18.
Artigo em Inglês | MEDLINE | ID: mdl-39188042

RESUMO

INTRODUCTION: Due to its unique features, pulsed field ablation (PFA) could potentially overcome some limitations of current radiofrequency (RF) ventricular tachycardia (VT) ablation. However, data on the use of PFA in this setting are currently scarce. METHODS: Two patients with ischemic cardiomyopathy and previously failed RF VT ablations were treated with PFA. RESULTS: A total of 18 bipolar applications (case1) and seven bipolar applications (case2) were delivered to the infero-lateral and infero-septal areas (case1) and to the apical lateral left ventricular (LV) wall (case2), placing the catheter adjacent to the LV wall in the flower configuration. A rapid cessation of VT and restoration of sinus rhythm were observed during PFA delivery in both cases. Further applications were delivered to achieve complete elimination of late potentials. In case 1, during the in-hospital stay, ECG monitoring did not show VT recurrences. Six-month follow-up was uneventful, with no VT recurrences at ICD interrogation. In case 2, due to postdischarge VT recurrences, a second RF procedure was scheduled 1 month later. The voltage map performed in sinus rhythm showed a low-voltage zone located at the anterolateral wall, near the previous ablation site. Numerous late potentials were recorded. At the 6-month follow-up, no further VT recurrences were documented after RF redo ablation. CONCLUSION: While the speed of application and potential transmural effect can facilitate the ablation of large diseased endocardial areas, early loss of contact due to difficult pentaspline catheter manipulation in the LV could lead to insufficient contact force and, consequently, inadequate energy penetration.

19.
J Cardiovasc Electrophysiol ; 35(6): 1174-1184, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38867544

RESUMO

INTRODUCTION: The left ventricular summit (LVS) is the highest point on the epicardial surface of the left ventricle. A part of the LVS that is located between the left coronary arteries (lateral-LVS) is one of the major sites of idiopathic ventricular arrhythmia (VA) origins. Some idiopathic epicardial VAs can be ablated at endocardial sites adjacent to the epicardial area septal to the lateral-LVS (septal-LVS). This study examined the prevalence and electrocardiographic and electrophysiological characteristics of septal-LVS VAs. METHODS: We studied consecutive patients with idiopathic VAs originating from the LVS (67 patients) and aortic root (93 patients). RESULTS: Based on the ablation results, among 67 LVS VAs, 54 were classified as lateral and 13 as septal-LVS VAs. As compared with the lateral-LVS VAs, the septal-LVS VAs were characterized by a greater prevalence of left bundle branch block with left inferior-axis QRS pattern, later precordial transition, lower R-wave amplitude ratio in leads III to II, lower Q-wave amplitude ratio in leads aVL to aVR, and later local ventricular activation time relative to the QRS onset during VAs (V-QRS) in the great cardiac vein. The electrocardiographic and electrophysiological characteristics of the septal-LVS VAs were similar to those of the aortic root VAs. However, the V-QRS at the successful ablation site was significantly later during the septal-LVS VAs than aortic root VAs (p < .0001). The precordial transition was significantly later during the septal-LVS VAs than aortic root VAs (p < .05). CONCLUSIONS: Septal-LVS VAs are considered a distinct subgroup of idiopathic VAs originating from the left ventricular outflow tract.


Assuntos
Potenciais de Ação , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Prevalência , Pessoa de Meia-Idade , Adulto , Idoso , Resultado do Tratamento , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/epidemiologia , Estudos Retrospectivos , Fatores de Tempo
20.
J Cardiovasc Electrophysiol ; 35(6): 1150-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38566579

RESUMO

INTRODUCTION: Proactive esophageal cooling has been FDA cleared to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures. Data suggest that procedure times for RF pulmonary vein isolation (PVI) also decrease when proactive esophageal cooling is employed instead of luminal esophageal temperature (LET) monitoring. Reduced procedure times may allow increased electrophysiology (EP) lab throughput. We aimed to quantify the change in EP lab throughput of PVI cases after the introduction of proactive esophageal cooling. METHODS: EP lab throughput data were obtained from three EP groups. We then compared EP lab throughput over equal time frames at each site before (pre-adoption) and after (post-adoption) the adoption of proactive esophageal cooling. RESULTS: Over the time frame of the study, a total of 2498 PVIs were performed over a combined 74 months, with cooling adopted in September 2021, November 2021, and March 2022 at each respective site. In the pre-adoption time frame, 1026 PVIs were performed using a combination of LET monitoring with the addition of esophageal deviation when deemed necessary by the operator. In the post-adoption time frame, 1472 PVIs were performed using exclusively proactive esophageal cooling, representing a mean 43% increase in throughput (p < .0001), despite the loss of two operators during the post-adoption time frame. CONCLUSION: Adoption of proactive esophageal cooling during PVI ablation procedures is associated with a significant increase in EP lab throughput, even after a reduction in total number of operating physicians in the post-adoption group.


Assuntos
Ablação por Cateter , Esôfago , Veias Pulmonares , Humanos , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Fatores de Tempo , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Resultado do Tratamento , Hipotermia Induzida , Fatores de Risco , Duração da Cirurgia , Técnicas Eletrofisiológicas Cardíacas , Fluxo de Trabalho , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA