Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 43(4): 735-745, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38361135

RESUMO

PURPOSE: This article aims to establish a rapid visual method for the detection of Streptococcus pyogenes (GAS) based on recombinase polymerase amplification (RPA) and lateral flow strip (LFS). METHODS: Utilizing speB of GAS as a template, RPA primers were designed, and basic RPA reactions were performed. To reduce the formation of primer dimers, base mismatch was introduced into primers. The probe was designed according to the forward primer, and the RPA-LFS system was established. According to the color results of the reaction system, the optimum reaction temperature and time were determined. Thirteen common clinical standard strains and 14 clinical samples of GAS were used to detect the selectivity of this method. The detection limit of this method was detected by using tenfold gradient dilution of GAS genome as template. One hundred fifty-six clinical samples were collected and compared with qPCR method and culture method. Kappa index and clinical application evaluation of the RPA-LFS were carried out. RESULTS: The enhanced RPA-LFS method demonstrates the ability to complete the amplification process within 6 min at 33 °C. This method exhibits a high analytic sensitivity, with the lowest detection limit of 0.908 ng, and does not exhibit cross-reaction with other pathogenic bacteria. CONCLUSIONS: The utilization of RPA and LFS allows for efficient and rapid testing of GAS, thereby serving as a valuable method for point-of-care testing.


Assuntos
Recombinases , Streptococcus pyogenes , Humanos , Streptococcus pyogenes/genética , Sensibilidade e Especificidade , Temperatura , Técnicas de Amplificação de Ácido Nucleico/métodos
2.
Anal Bioanal Chem ; 416(15): 3509-3518, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38647692

RESUMO

Escherichia coli O157:H7 (E. coli O157:H7) is a foodborne pathogenic microorganism that is commonly found in the environment and poses a significant threat to human health, public safety, and economic stability worldwide. Thus, early detection is essential for E. coli O157:H7 control. In recent years, a series of E. coli O157:H7 detection methods have been developed, but the sensitivity and portability of the methods still need improvement. Therefore, in this study, a rapid and efficient testing platform based on the CRISPR/Cas12a cleavage reaction was constructed. Through the integration of recombinant polymerase amplification and lateral flow chromatography, we established a dual-interpretation-mode detection platform based on CRISPR/Cas12a-derived fluorescence and lateral flow chromatography for the detection of E. coli O157:H7. For the fluorescence detection method, the limits of detection (LODs) of genomic DNA and E. coli O157:H7 were 1.8 fg/µL and 2.4 CFU/mL, respectively, within 40 min. Conversely, for the lateral flow detection method, LODs of 1.8 fg/µL and 2.4 × 102 CFU/mL were achieved for genomic DNA and E. coli O157:H7, respectively, within 45 min. This detection strategy offered higher sensitivity and lower equipment requirements than industry standards. In conclusion, the established platform showed excellent specificity and strong universality. Modifying the target gene and its primers can broaden the platform's applicability to detect various other foodborne pathogens.


Assuntos
Sistemas CRISPR-Cas , Escherichia coli O157 , Limite de Detecção , Escherichia coli O157/genética , Escherichia coli O157/isolamento & purificação , DNA Bacteriano/análise , DNA Bacteriano/genética , Microbiologia de Alimentos/métodos , Proteínas Associadas a CRISPR/genética , Humanos , Endodesoxirribonucleases/genética
3.
Anal Bioanal Chem ; 413(18): 4665-4672, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34018036

RESUMO

Recombinase polymerase amplification (RPA) was combined with lateral flow to develop a gold nanoparticles test strip for point-of-care diagnosis of African swine fever virus (ASFV), which is called lateral flow gene assay (LFGA). Common diagnostic techniques, including polymerase chain reaction (PCR) and immunochromatography, are time-consuming and labor-intensive, and generally require costly instruments. For improvement, this assay used tailed primers to produce DNA duplexes with a single-stranded tail at one end which can hybridize with a gold nanoparticle (AuNP)-labeled oligonucleotide detection probe. And then, biotin attached to the other end of the product bound to streptavidin, which previously fixed to the test line. Therefore, there would form a sandwich structure, and gold nanoparticles labeled on the detection probe would show a red band on the test line of strip. With the low reaction temperature (37~42 °C) and short reaction time (30 min), LFGA can specifically identify ASFV in blood samples infected with ASFV and classical swine fever virus (CSFV), and the LOD was 102 copies/µL, which was comparable to that of agarose gel electrophoresis. In addition, blood samples infected with ASFV and CSFV were tested, and it was found that the LFGA can specifically identify ASFV DNA. In conclusion, LFGA achieves visual observation of the product after rapid RPA amplification and does not require any expensive instruments during the entire process, which is very helpful for early diagnosis of ASFV. Combined recombinase polymerase amplification (RPA) with lateral flow, we developed a gold nanoparticles test strip for point-of-care diagnosis of African swine fever virus. The upstream primers of RPA were modified with biotin, and the downstream primers were modified with a C3 spacer and an oligonucleotide tail that can be hybridized to a gold nanoparticle-labeled oligonucleotide detection probe. On the strip, the test line and control line were sprayed with streptavidin and an oligonucleotide control probe. In the presence of positive products, RPA products can form a sandwich structure on the test line. Therefore, two red lines will be displayed both on the test line and control line. When there is no positive product, only the control line is shown in red. Its low reaction temperature (37~42 °C) and short time of amplification and detection (30 min) make ASFV realizing point-of-care diagnosis in limited environment.


Assuntos
Febre Suína Africana/diagnóstico , Ouro/química , Nanopartículas Metálicas/química , Técnicas de Amplificação de Ácido Nucleico/métodos , Testes Imediatos , Animais , Sensibilidade e Especificidade , Suínos
4.
Anal Biochem ; 556: 16-22, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29920236

RESUMO

DNA biosensors are attractive tools for genetic analysis as there is an increasing need for rapid and low-cost DNA analysis, primarily driven by applications in personalized pharmacogenomics, clinical diagnostics, rapid pathogen detection, food traceability and forensics. A rapid electrochemical genosensor detection methodology exploiting a combination of modified primers for solution-phase isothermal amplification, followed by rapid detection via hybridization on gold electrodes is reported. Modified reverse primers, exploiting a C18 spacer between the primer-binding site and an engineered single stranded tail, are used in a recombinase polymerase amplification reaction to produce an amplicon with a central duplex flanked by two single stranded tails. These tails are designed to be complementary to a gold electrode tethered capture oligo probe as well as a horseradish peroxidase labelled reporter oligo probe. The time required for hybridization of the isothermally generated amplicons with each of the immobilized and reporter probes was optimised to be 2 min, in both cases. The effect of amplification time and the limit of detection were evaluated using these hybridization times for both single stranded and double stranded DNA templates. The best detection limit of 70 fM for a ssDNA template was achieved using 45 min amplification, whilst for a dsDNA template, just 30 min amplification resulted in a slightly lower detection limit of 14 fM, whilst both 20 and 45 min amplification times were observed to provide detection limits of 71 and 72 fM, respectively, but 30 and 45 min amplification resulted in a much higher signal and sensitivity. The genosensor was applied to genomic DNA and real patient and control blood samples for detection of the coeliac disease associated DQB1*02 HLA allele, as a model system, demonstrating the possibility to carry out molecular diagnostics, combining amplification and detection in a rapid and facile manner.


Assuntos
Doença Celíaca/genética , Primers do DNA/genética , Técnicas Eletroquímicas/métodos , Cadeias beta de HLA-DQ/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Alelos , Humanos
5.
Animals (Basel) ; 14(17)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39272312

RESUMO

The porcine circovirus type 3 (PCV3) infection is an emerging disease associated with clinical signs of porcine dermatitis and nephropathy syndrome (PDNS)-like clinical signs. Currently, there is a lack of effective vaccines and therapeutics against this disease. Therefore, rapid, effective, sensitive, and specific detection methods are crucial for the timely identification, prevention, and control of PCV3. In this study, we developed one- and two-pot visual detection methods for PCV3 using a clustered regularly interspaced short palindromic repeat (CRISPR)/Cas12a detection system combined with recombinase polymerase amplification (RPA). These two methods demonstrated no cross-reactivity with eight other swine viruses and exhibited minimum detection limits of five and two copies of viral DNA, respectively, revealing their high specificity and sensitivity. During a clinical sample detection within 30 min, the coincidence rates between the one- and two-pot detection methods and real-time quantitative polymerase chain reaction (qPCR) were 100%. In conclusion, both one- and two-pot RPA-CRISPR/Cas12a detection methods have significant potential for the rapid, sensitive, and specific visual detection of PCV3.

6.
Microorganisms ; 10(7)2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35889071

RESUMO

In recent years, foodborne disease outbreaks have caused huge losses to the economy and have had severe impacts on public health. The accuracy and variety of detection techniques is crucial to controlling the outbreak and spread of foodborne diseases. The need for instruments increases the difficulty of field detection, while manually-handled samples are subject to user error and subjective interpretation. Here, we use a mini automatic nucleic acid extractor combined with recombinant polymerase amplification (RPA) and lateral flow immunoassay (LFIA) for simultaneous quantitative detection of five major foodborne pathogens. The pre-treatment device using the magnetic bead method allows for nucleic acid extraction of the reagent tank without manual operation, which is highly efficient and stable for preventing aerosol contamination. The nuc gene of Staphylococcus aureus, the toxR gene of Vibrio parahaemolyticus, the rfbE gene of Escherichia coli O157:H7, the hlyA gene of Listeria monocytogenes, and the fimY gene of Salmonella enterica were used as target fragments. The labeled antibody concentration is optimized on the LFIA to find the equilibrium point for the binding capacity of the five chemical markers and to efficiently and accurately visualize the bands. The RPA assay shows an optimal performance at 37 °C for 15 min. The optimized RPA-LFIA detection limit can reach 101 CFU/mL. There was no cross-reactivity among forty-eight strains. Furthermore, the average recoveries in spiked food samples were 90.5-104.5%. In summary, the RPA-LFIA established in this study can detect five pathogenic bacteria simultaneously with little dependence on laboratory equipment, and it has promising prospects for screening in low-resource areas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA