Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 50(6): 1743-1752, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36650357

RESUMO

BACKGROUND: There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC). PURPOSE: To evaluate the efficacy of prospective voxel-based dosimetry for predicting treatment response and adverse events (AEs) in patients with HCC undergoing resin-based Y90 radioembolization. MATERIALS AND METHODS: This correlative study was based on a prospective single-arm clinical trial (NCT04172714), which evaluated the efficacy of low/scout (555 MBq) activity of resin-based Y90 for treatment planning. Partition model was used with goal of tumor dose (TD) > 200 Gy and non-tumoral liver dose (NTLD) < 70 Gy for non-segmental therapies. Single compartment dose of 200 Gy was used for segmentectomies. Prescribed Y90 activity minus scout activity was administered for therapeutic Y90 followed by Y90-PET/CT. Sureplan® (MIM Software, Cleveland, OH) was used for dosimetry analysis. Treatment response was evaluated at 3 and 6 months. Receiver operating characteristic curve determined TD response threshold for objective response (OR) and complete response (CR) as well as non-tumor liver dose (NTLD) threshold that predicted AEs. RESULTS: N = 30 patients were treated with 33 tumors (19 segmental and 14 non-segmental). One patient died before the first imaging, and clinical follow-up was excluded from this analysis. Overall, 26 (81%) of the tumors had an OR and 23 (72%) had a CR. A mean TD of 253 Gy predicted an OR with 92% sensitivity and 83% specificity (area under the curve (AUC = 0.929, p < 0.001). A mean TD of 337 Gy predicted a CR with 83% sensitivity and 89% specificity (AUC = 0.845, p < 0.001). A mean NTLD of 81 and 87 Gy predicted grade 3 AEs with 100% sensitivity and 100% specificity in the non-segmental cohort at 3- and 6-month post Y90, respectively. CONCLUSION: In patients with HCC undergoing resin-based Y90, there are dose response and dose toxicity thresholds directly affecting outcomes. CLINICAL TRIAL NUMBER: NCT04172714.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Microesferas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Resultado do Tratamento , Radioisótopos de Ítrio/efeitos adversos
2.
Eur J Nucl Med Mol Imaging ; 49(5): 1682-1699, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35146577

RESUMO

Primary liver tumours (i.e. hepatocellular carcinoma (HCC) or intrahepatic cholangiocarcinoma (ICC)) are among the most frequent cancers worldwide. However, only 10-20% of patients are amenable to curative treatment, such as resection or transplant. Liver metastases are most frequently caused by colorectal cancer, which accounts for the second most cancer-related deaths in Europe. In both primary and secondary tumours, radioembolization has been shown to be a safe and effective treatment option. The vast potential of personalized dosimetry has also been shown, resulting in markedly increased response rates and overall survival. In a rapidly evolving therapeutic landscape, the role of radioembolization will be subject to changes. Therefore, the decision for radioembolization should be taken by a multidisciplinary tumour board in accordance with the current clinical guidelines. The purpose of this procedure guideline is to assist the nuclear medicine physician in treating and managing patients undergoing radioembolization treatment. PREAMBLE: The European Association of Nuclear Medicine (EANM) is a professional non-profit medical association that facilitates communication worldwide among individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. These guidelines are intended to assist practitioners in providing appropriate nuclear medicine care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by medical professionals taking into account the unique circumstances of each case. Thus, there is no implication that an approach differing from the guidelines, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set out in the guidelines when, in the reasonable judgment of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources or advances in knowledge or technology subsequent to publication of the guidelines. The practice of medicine involves not only the science but also the art of dealing with the prevention, diagnosis, alleviation and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognised that adherence to these guidelines will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources and the needs of the patient to deliver effective and safe medical care. The sole purpose of these guidelines is to assist practitioners in achieving this objective.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Neoplasias dos Ductos Biliares/tratamento farmacológico , Ductos Biliares Intra-Hepáticos/patologia , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/radioterapia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Microesferas , Radioisótopos de Ítrio/uso terapêutico
3.
BMC Gastroenterol ; 22(1): 151, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35346070

RESUMO

BACKGROUND: Selective internal radiation therapy (SIRT) with yttrium-90 (90Y) resin microspheres is an established locoregional treatment option for unresectable hepatocellular carcinoma (HCC), which delivers a lethal dose of radiation to hepatic tumors, while sparing surrounding healthy tissue. DOORwaY90 is a prospective, multicenter, open-label, single arm study, designed to evaluate the safety and effectiveness of 90Y resin microspheres as first-line treatment in patients with unresectable/unablatable HCC. It is unique in that it is the first study with resin microspheres to utilize a personalized 90Y dosimetry approach, and independent review for treatment planning and response assessment. METHODS: Eligibility criteria include unresectable/unablatable HCC, Barcelona Clinic Liver Cancer stage A, B1, B2, or C with a maximal single tumor diameter of ≤ 8 cm, and a sum of maximal tumor diameters of ≤ 12 cm, and at least one tumor ≥ 2 cm (long axis) per localized, modified Response Evaluation Criteria in Solid Tumors. Partition model dosimetry is used to determine the optimal dose; the target mean dose to tumor is ≥ 150 Gy. Patients are assessed at baseline and at regular intervals up until 12 months of treatment for response rates, safety, and quality of life (QoL). Post-treatment dosimetry is used to assess dose delivered to tumor and consider if retreatment is necessary. The co-primary endpoints are best objective response rate and duration of response. Secondary endpoints include grade ≥ 3 toxicity, QoL, and incidence of liver resection and transplantation post SIRT. Target recruitment is 100 patients. DISCUSSION: The results of this trial should provide further information on the potential use of SIRT with 90Y resin microspheres as first-line therapy for unresectable HCC. TRIAL REGISTRATION: Clinicaltrials.gov; NCT04736121; date of 1st registration, January 27, 2021, https://clinicaltrials.gov/ct2/show/NCT04736121 .


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/patologia , Ensaios Clínicos como Assunto , Humanos , Neoplasias Hepáticas/patologia , Microesferas , Estudos Prospectivos , Qualidade de Vida
4.
Future Oncol ; 16(1): 4315-4325, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31797680

RESUMO

Aim: To determine whether a liver tumor burden ≤25% and well-preserved liver function (albumin-bilirubin grade 1) are appropriate criteria for identifying patients with unresectable hepatocellular carcinoma who may benefit from selective internal radiation therapy (SIRT) using 90yttrium resin microspheres versus sorafenib. Patients & methods: Post-hoc analysis of patients in the intention-to-treat population of the SARAH trial (SIRT vs sorafenib) with ≤25% tumor burden and albumin-bilirubin grade 1. Primary end point: overall survival. Results: Median overall survival was 21.9 months (95% CI: 15.2-32.5, n = 37) with SIRT and 17.0 months (11.6-20.8, n = 48) with sorafenib (hazard ratios: 0.73; 95% CI: 0.44-1.21; p = 0.22). Conclusion: A combination of good liver function and low tumor burden may be relevant for selection of hepatocellular carcinoma patients for SIRT.


Assuntos
Antineoplásicos/uso terapêutico , Braquiterapia/mortalidade , Carcinoma Hepatocelular/mortalidade , Neoplasias Hepáticas/mortalidade , Seleção de Pacientes , Sorafenibe/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Idoso , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/radioterapia , Feminino , Seguimentos , Humanos , Testes de Função Hepática , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/radioterapia , Masculino , Microesferas , Prognóstico , Taxa de Sobrevida , Carga Tumoral
5.
Eur J Nucl Med Mol Imaging ; 46(11): 2270-2279, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31324943

RESUMO

PURPOSE: Reported outcomes of patients with intra-hepatic cholangiocarcinoma (IH-CCA) treated with radioembolization are highly variable, which indicates differences in included patients' characteristics and/or procedure-related variables. This study aimed to identify patient- and treatment-related variables predictive for radioembolization outcome. METHODS: This retrospective multicenter study enrolled 58 patients with unresectable and chemorefractory IH-CCA treated with resin 90Y-microspheres. Clinicopathologic data were collected from patient records. Metabolic parameters of liver tumor(s) and presence of lymph node metastasis were measured on baseline 18F-FDG-PET/CT. 99mTc-MAA tumor to liver uptake ratio (TLRMAA) was computed for each lesion on the SPECT-CT. Activity prescription using body-surface-area (BSA) or more personalized partition-model was recorded. The study endpoint was overall survival (OS) starting from date of radioembolization. Statistical analysis was performed by the log-rank test and multivariate Cox's proportional hazards model. RESULTS: Median OS (mOS) post-radioembolization of the entire cohort was 10.3 months. Variables associated with significant differences in terms of OS were serum albumin (hazard ratio (HR) = 2.78, 95%CI:1.29-5.98, p = 0.002), total bilirubin (HR = 2.17, 95%CI:1.14-4.12, p = 0.009), aspartate aminotransferase (HR = 2.96, 95%CI:1.50-5.84, p < 0.001), alanine aminotransferase (HR = 2.02, 95%CI:1.05-3.90, p = 0.01) and γ-GT (HR = 2.61, 95%CI:1.31-5.22, p < 0.001). The presence of lymph node metastasis as well as a TLRMAA < 1.9 were associated with shorter mOS: HR = 2.35, 95%CI:1.08-5.11, p = 0.008 and HR = 2.92, 95%CI:1.01-8.44, p = 0.009, respectively. Finally, mOS was significantly shorter in patients treated according to the BSA method compared to the partition-model: mOS of 5.5 vs 14.9 months (HR = 2.52, 95%CI:1.23-5.16, p < 0.001). Multivariate analysis indicated that the only variable that increased outcome prediction above the clinical variables was the activity prescription method with HR of 2.26 (95%CI:1.09-4.70, p = 0.03). The average mean radiation dose to tumors was significantly higher with the partition-model (86Gy) versus BSA (38Gy). CONCLUSION: Radioembolization efficacy in patients with unresectable recurrent and/or chemorefractory IH-CCA strongly depends on the tumor radiation dose. Personalized activity prescription should be performed.


Assuntos
Colangiocarcinoma/tratamento farmacológico , Colangiocarcinoma/radioterapia , Embolização Terapêutica , Medicina de Precisão , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Resultado do Tratamento
6.
Eur J Nucl Med Mol Imaging ; 45(10): 1721-1730, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29516130

RESUMO

PURPOSE: Radioembolisation is part of the multimodal treatment of hepatocellular carcinoma (HCC) at specialist liver centres. This study analysed the impact of prior treatment on tolerability and survival following radioembolisation. METHODS: This was a retrospective analysis of 325 consecutive patients with a confirmed diagnosis of HCC, who received radioembolisation with yttrium-90 resin microspheres at eight European centres between September 2003 and December 2009. The decision to treat was based on the clinical judgement of multidisciplinary teams. Patients were followed from the date of radioembolisation to last contact or death and the nature and severity of all adverse events (AEs) recorded from medical records. RESULTS: Most radioembolisation candidates were Child-Pugh class A (82.5%) with multinodular HCC (75.9%) invading both lobes (53.1%); 56.3% were advanced stage. Radioembolisation was used first-line in 57.5% of patients and second-line in 34.2%. Common prior procedures were transarterial (chemo)embolisation therapies (27.1%), surgical resection/transplantation (17.2%) and ablation (8.6%). There was no difference in AE incidence and severity between prior treatment subgroups. Median (95% confidence interval [CI]) survival following radioembolisation was similar between procedure-naive and prior treatment groups for Barcelona Clinic Liver Cancer (BCLC) stage A: 22.1 months (15.1-45.9) versus 30.9 months (19.6-46.8); p = 0.243); stage B: 18.4 months (11.2-19.4) versus 22.8 months (10.9-34.2); p = 0.815; and stage C: 8.8 months (7.1-10.8) versus 10.8 months (7.7-12.6); p = 0.976. CONCLUSIONS: Radioembolisation is a valuable treatment option for patients who relapse following surgical, ablative or vascular procedures and remain suitable candidates for this treatment.


Assuntos
Carcinoma Hepatocelular/radioterapia , Embolização Terapêutica , Neoplasias Hepáticas/radioterapia , Fígado/efeitos da radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Segurança , Análise de Sobrevida , Adulto Jovem
7.
Future Oncol ; 13(23): 2065-2082, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28703622

RESUMO

A Spanish expert panel reviewed current evidence for the use of SIR-Spheres Y-90 resin microspheres in patients with chemotherapy refractory/intolerant unresectable colorectal liver metastases. Substantial evidence for its efficacy and safety is available from a randomized controlled study, retrospective comparative studies and several single arm studies. Clinical evidence data obtained from more than 1500 patients have led to the inclusion of selective internal radiation therapy in the 2016 ESMO Clinical Guidelines as third-line treatment. This publication results from an expert panel meeting, where published evidence and author's experiences were shared to position SIR-Spheres Y-90 resin microspheres in Spain for the treatment of chemotherapy refractory/intolerant unresectable colorectal liver metastases, and second, to define the patient subgroup that will benefit the most with this treatment.


Assuntos
Neoplasias Colorretais/patologia , Embolização Terapêutica , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Microesferas , Radioisótopos de Ítrio/administração & dosagem , Resistencia a Medicamentos Antineoplásicos , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/mortalidade , Retratamento , Resultado do Tratamento
8.
Asia Pac J Clin Oncol ; 20(2): 319-322, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36658669

RESUMO

About 80% of hepatocellular carcinoma (HCC) patients are in advanced stages and ineligible for curative surgery. Palliative treatments just maintained limited survival, thus an effective downstaging therapy is badly needed. Here we report an initially unresectable patient who underwent radical hepatectomy after successful downstaging with selective internal radiation therapy (SIRT). A 34-year-old man was diagnosed with China Liver Cancer Staging (CNLC) IIIa HCC. Due to insufficient future liver remnant and vascular involvement, the patient was suggested to be unresectable. SIRT with yttrium-90 resin microspheres was given. At three months post-SIRT, a complete response was achieved. The tumor was downstaged to CNLC Ia stage. The patient underwent anatomical hepatectomy 5 months after SIRT. Histopathological examination of the resected specimen showed 4% viable tumor cells inside a necrotic mass. To our knowledge, this is the first case who underwent SIRT with yttrium-90 resin microspheres in China mainland. The success of the downstaging in this case renders a possible cure to be achieved in an initially unresectable patient. In addition, the nearly complete tumor necrosis in the resected specimen indicates a good prognosis post-surgery. This is the first case who underwent SIRT with yttrium-90 resin microspheres in China mainland. SIRT followed by anatomical hepatectomy is a potentially curative strategy for unresectable HCC, which deserves a confirmative trial in the future.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Masculino , Humanos , Adulto , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Hepatectomia , Microesferas , Radioisótopos de Ítrio/uso terapêutico
9.
J Chromatogr A ; 1720: 464785, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38458141

RESUMO

Amphiphilic materials can be used for sample preparation of chromatography or mass spectrometry. Amphiphilic materials with magnetic properties in combination with magnetic suction devices allow for automated sample preparation. However, conventional synthesis methods are cumbersome and not suitable for the mass production of the material. In this study, a micro-suspension polymerization method was developed to synthesize magnetic amphiphilic resin microspheres (MARMs), providing new ideas for the preparation of amphiphilic microspheres. MARMs with particle sizes ranging from 3 to 6 µm were successfully prepared, with BET surface area up to 653.2 m2/g. A magnetic solid-phase extraction method based on MARM-5 was developed for the extraction of four glucocorticoids including Cortisone, Hydrocortisone, Cortodoxone, and Corticosterone. This method had a very short adsorption time of 0.5 min and a total extraction time of only 13 min. The limit of detection for the four glucocorticoids ranged from 0.22 to 0.82 ng/L. There was a good linear relationship between sample concentration and peak area in the range of 25∼500 ng/L. Relative recovery of 98 %∼108 % and internal standard normalized matrix effect factors of 95∼114 % were obtained, and the relative standard deviation was between 2.3 % and 6.3 %. The MARMs would be used as excellent solid extraction material for glucocorticoids.


Assuntos
Glucocorticoides , Espectrometria de Massa com Cromatografia Líquida , Microesferas , Polimerização , Fenômenos Magnéticos , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão
10.
J Nucl Med ; 64(5): 825-828, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36418169

RESUMO

Dosimetry-guided treatment planning in selective internal radiation therapy relies on accurate and reproducible measurement of administered activity. This 4-center, 5-PET-device study compared the manufacturer-declared 90Y activity in vials with quantitative 90Y PET/CT assessment of the same vials. We compared 90Y PET-measured activity (APET) for 56 90Y-labeled glass and 18 90Y-labeled resin microsphere vials with the calibrated activity specified by the manufacturer (AM). Additionally, the same analysis was performed for 4 90Y-chloride vials. The mean APET/AM ratio was 0.79 ± 0.04 (range, 0.71-0.89) for glass microspheres and 1.15 ± 0.06 (range, 1.05-1.25) for resin microspheres. The mean APET/AM ratio for 90Y-chloride vials was 1.00 ± 0.04 (range, 0.96-1.06). Thus, we found an average difference of 46% between glass and resin microsphere activity calibrations, whereas close agreement was found for chloride solutions. We expect that the reported discrepancies will promote further investigations to establish reliable and accurate patient dosimetry and dose-effect assessments.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Microesferas , Cloretos , Radiometria , Radioisótopos de Ítrio , Vidro
11.
Diagn Interv Radiol ; 29(5): 704-709, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-36994546

RESUMO

PURPOSE: To analyze changes in angiogenesis factors after transarterial radioembolization (TARE) with Yttrium- 90-loaded resin microspheres in hepatocellular carcinoma (HCC) patients. METHODS: Interleukin-6, interleukin-8, hepatocyte growth factor, platelet-derived growth factor, fibroblast growth factor, vascular endothelial growth factor-A (VEGF-A), and angiopoietin-2 levels in 26 patients were measured before TARE and on day 1, 7, 14, and 30 after TARE and evaluated regarding radiological response. RESULTS: In the sixth month of follow-up, 11 (42.30%) patients had a complete or partial response to treatment, while progressive disease was found in 15 (57.69%) patients. The percentage changes in VEGF-A in the non-responders on day 30 (P = 0.034) after TARE were significantly more obvious. Peak formation rates of VEGF-A were higher in non-responders (P = 0.036). CONCLUSION: Short-term changes in angiogenesis factors in HCC patients after TARE with Yttrium-90-loaded resin microspheres fluctuate with different amplitudes at different times. The upregulation of growth factors has a prognostic capacity. Changes in VEGF-A after TARE may be helpful for the early recognition of non-responders.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/irrigação sanguínea , Fator A de Crescimento do Endotélio Vascular , Neoplasias Hepáticas/patologia , Radioisótopos de Ítrio/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento
12.
J Med Econ ; 26(1): 731-741, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37139828

RESUMO

AIMS: Hepatocellular carcinoma (HCC) is a severe condition with poor prognosis that places a significant burden on patients, caregivers, and healthcare systems. Selective internal radiation therapy (SIRT) is a treatment available to patients with HCC which addresses some of the limitations of alternative treatment options. A cost-effectiveness analysis was undertaken into the use of SIRT using Y-90 resin microspheres for the treatment of unresectable intermediate- and late-stage HCC in Brazil. MATERIALS AND METHODS: A partitioned-survival model was developed, including a tunnel state for patients downstaged to receive treatments with curative intent. Sorafenib was the selected comparator, a common systemic treatment in Brazil and for which comparative evidence exists. Clinical data were extracted from published sources of pivotal trials, and effectiveness was measured in quality-adjusted life-years (QALYs) and life-years (LYs). The analysis was conducted from the Brazilian private payer perspective and a lifetime horizon was implemented. Comprehensive sensitivity analyses were conducted. RESULTS: LYs and QALYs were higher for SIRT with Y-90 resin microspheres versus sorafenib (0.27 and 0.20 incremental LYs and QALYs, respectively) and costs were slightly higher for SIRT (R$15,864). The base case incremental cost-effectiveness ratio (ICER) was R$77,602 per QALY. The ICER was mostly influenced by parameters defining the sorafenib overall survival curve and SIRT had a 73% probability of being cost-effective at a willingness-to-pay threshold of R$135,761 per QALY (3-times the per-capita gross domestic product in Brazil). Overall, sensitivity analyses confirmed the robustness of the results indicating that SIRT with Y-90 resin microspheres is cost-effective compared with sorafenib. LIMITATIONS: A rapidly evolving treatment landscape in Brazil and worldwide, and the lack of local data for some variables were the main limitations. CONCLUSIONS: SIRT with Y-90 resin microspheres is a cost-effective option compared with sorafenib in Brazil.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/tratamento farmacológico , Sorafenibe/uso terapêutico , Análise Custo-Benefício , Radioisótopos de Ítrio , Brasil , Neoplasias Hepáticas/tratamento farmacológico , Microesferas
14.
Anal Chim Acta ; 1061: 122-133, 2019 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-30926030

RESUMO

A facile and efficient method for the determination of triazine herbicides in tomato samples was developed by employing 3-aminophenol-glyoxylic acid resin microspheres as a solid-phase extraction adsorbent followed by high performance liquid chromatography analysis. These resin microspheres were synthesized by a simple green precipitation polymerization method, and a range of functional groups (hydroxyl, amino, carboxylic group) were introduced through the 3-aminophenol and glyoxylic acid components. The as-prepared resin microspheres were characterized by scanning electron microscopy, Fourier transform infrared spectrometry, and thermal gravimetric analyzer. The resin microspheres exhibited a good adsorption rate, large adsorption amount, and short adsorption equilibrium time (almost in ∼5 min). Under the optimal extraction and determination conditions, a good linearity was obtained in the range of 0.025-7.5 µg g-1 (r2 ≥ 0.9997) for atraton, ametryn, and prometryn. The limits of detection of atraton, ametryn, and prometryn were 0.57, 0.75, and 1.06 µg kg-1, respectively. The intra-day and inter-day precisions expressed as relative standard deviations were in the ranges of 1.8-3.2% and 1.7-4.1%, respectively. In addition, the recoveries at three spiked levels ranged from 85.1 to 97.7% with the relative standard deviation ≤ 5.4% (n = 3). This novel method is simple and accurate and has proved to be a reliable alternative method for the determination of triazine herbicides in tomato samples.


Assuntos
Aminofenóis/química , Contaminação de Alimentos/análise , Glioxilatos/química , Herbicidas/análise , Solanum lycopersicum/química , Triazinas/análise
15.
Front Oncol ; 9: 624, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31355141

RESUMO

Background: This Phase II, open-label, study examined the safety of regorafenib followed by selective internal radiation therapy (SIRT) with regorafenib re-initiation in the treatment of metastatic colorectal cancer (mCRC) patients with liver metastases who are not surgical candidates. Methods: Patients received 160 mg regorafenib daily on a 21-day course followed by a 1 week washout prior to SIRT. Liver function was evaluated at 2 and 4 weeks after SIRT, and regorafenib re-initiated if liver function was normal. Patients were evaluated for safety, and restaged at weeks 6 and 12 following SIRT. In addition, protein and cytokine assays of blood were performed to identify candidate molecular biomarkers associated with outcomes. Individual patient voxel-based dosimetry assessment was performed post-SIRT. Results: Twenty-Five patients were enrolled and received a median 11 weeks regorafenib. Three patients received regorafenib, but not SIRT due to disease progression. The remaining 22 patients received SIRT with a median activity delivered to the liver of 38 mCi, mean normal liver dose of 14.98 Gy and tumor mean dose of 29.0 Gy with a tumor to normal ratio mean of 2.42. There were four treatment-related serious AEs and no treatment-related deaths. Median progression-free survival was 3.7 months and the median overall survival was 12.1 months. The relative densities of several biomolecules changed significantly during the course of treatment, most notably post-treatment increases in levels of sex-hormone binding globulin (SHBG) and decreased levels of the cytokine MIG (CXL9). Decreases in von Willebrand factor (VWF), the ankyrin repeat domain (ANKRD26), and MIG were associated with improved survival times. Post-treatment increases in alpha-2-macroglobulin (A2M) and the cytokine intercellular adhesion molecule (ICAM-1) were associated with reduced overall survival time, while increases in Eotaxin (CCL14) predicted longer overall survival times. Conclusions: The treatment of mCRC patients with liver metastases using regorafenib followed by SIRT was tolerable in this patient population. Further efficacy analysis of this treatment schema and analysis of potential molecular biomarkers using larger sample sizes is merited.

16.
Nanomaterials (Basel) ; 7(9)2017 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-28878158

RESUMO

Influence of the excess monomer within the synthetic reaction solution of melamine resin microspheres (MFMSs) on the surface-enhanced Raman spectroscopy (SERS) enhancement from Rhodamine 6G (R6G) was investigated, where the R6G was adsorbed on the silver nanoparticles (AgNPs) that were loaded on the MFMSs. Surface characteristics of the MFMSs were modified by the excess monomer (i.e., the excessive melamine or formaldehyde) through its terminal overreaction, which can be simply controlled by some of the synthetic reaction conditions, thus further allowing us to optimize the assembly of the loaded AgNPs for the SERS detection. These SERS substrates incorporating the optimized MFMSs with the excess formaldehyde can also be used for tracing analyses of more environmental and food contaminants.

17.
J Gastrointest Oncol ; 8(2): 266-278, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28480066

RESUMO

Hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) often present at stages where patients have limited treatment options. Use of selective internal radiation therapy (SIRT) with yttrium-90 (Y-90) resin microspheres has progressed as data increasingly speak to its utility in patients with both intermediate and late stage disease in these cancers. In anticipation of the pending completion of several prospective randomized controlled multicenter studies exploring the use of Y-90 resin microspheres in primary liver cancers, this article outlines mechanisms involved in SIRT administration and reviews key efficacy and safety data that are currently available in the literature involving use of this therapy in both HCC and ICC.

18.
Appl Radiat Isot ; 109: 226-230, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26712330

RESUMO

The use of (90)Y resin microspheres (SIR-Spheres® microspheres) in Nuclear Medicine has dramatically increased in recent years due to its favourable outcome in the treatment of liver cancer and liver metastases (Rajekar et al., 2011). The measurement of administered activity before and residual activity after treatment in radionuclide calibrators is required to determine total activity delivered to the patient. In comparison with External Beam Radiotherapy (EBRT) where administered doses are often know to within ±5%, the actual administered activity in nuclear medicine procedures may only be known to within ±20% and subsequent dose calculations can result in even larger uncertainties (Fenwick et al., 2009). It is a well-recognised issue that ion chambers are instruments that are sensitive to the measurement geometry and matrix of a source, in particular for pure beta or low energy (<100keV) x-ray emitters (Gadd et al., 2006). This paper presents new calibration factors for NPL secondary standard ionisation chamber system (Vinten 671) and a Capintec CRC-25R radionuclide calibrator along with a discussion of the measurement problems associated with this radionuclide and matrix. Calibration of the NPL secondary standard system for this measurement matrix will enable NPL to provide standards for the Nuclear Medicine community and consequently increase the measurement capability.


Assuntos
Resinas Acrílicas/química , Calibragem/normas , Radiometria/instrumentação , Radiometria/normas , Radioisótopos de Ítrio/análise , Radioisótopos de Ítrio/normas , Resinas Acrílicas/normas , Braquiterapia/normas , Microesferas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Reino Unido
19.
Cardiovasc Intervent Radiol ; 39(12): 1743-1749, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27743088

RESUMO

BACKGROUND: Intra-arterial brachytherapy with yttrium-90 (90Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of 90Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model. METHODS: In each of six pigs, ~25-33 % of the kidney volume was embolized with 90Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8-9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from 90Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed. RESULTS: Kidneys embolized with 90Y-radioembolization decreased in mass by 30-70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the 90Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 106) of bland microspheres. CONCLUSION: This study showed that radioembolization with 90Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of 90Y resin microspheres for the localized treatment of kidney tumors.


Assuntos
Braquiterapia/métodos , Rim/patologia , Rim/efeitos da radiação , Microesferas , Radioisótopos de Ítrio/administração & dosagem , Animais , Modelos Animais de Doenças , Fluoroscopia , Necrose , Tamanho do Órgão , Suínos
20.
Eur J Radiol ; 85(9): 1525-31, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27501884

RESUMO

PURPOSE: Aim of the study was to evaluate the impact of parenchymal blood volume (PBV) C-arm CT in transarterial radioembolization (TARE) planning procedure regarding the appropriateness of segmental blood supply from selective catheter positions defined by angiographic images compared to PBV mapsto determine the influence of changed target volumes on dose calculation. MATERIAL AND METHODS: A total of 22 consecutive patients (median age, 62 years) underwent a TARE planning procedure were included in this retrospective study. Selective angiograms and selective PBV C-arm CT (right and left liver lobe) were evaluated in a blinded fashion, regarding segmental hepatic artery variants. Volumetry of target volume and dosimetry of glass and resin microspheres were performed. RESULTS: Classification of segment IV and segment I to the corresponding target vascular bed supply was correct in 91.0% (20/22) and 86.4% (19/22) for angiography and C-arm CT, respectively. Except one case, all other liver segments were classified properly to the left and right hepatic arterial supply. Based on the mismatch of the angiographic and the C-arm CT approach, changes of target volume were evident in 27.3% of patients, resulting in a mean mismatch volume of 90±54ml (range, 51-198ml) and a percentage of dose differences of 14.2±11.8% and 12.6±10.6% for the right and 12.5±8.5% and 11.1±7.8% for the left liver lobe in glass and resin microspheres, respectively. CONCLUSION: The C-arm CT approach is superior to the angiographic determination of vascular supply of specific liver segments for dosimetry before radioembolization. Especially for unexperienced interventional radiologists or for a complex anatomy, C-arm CT improves individualized dosimetry concepts.


Assuntos
Volume Sanguíneo/efeitos da radiação , Embolização Terapêutica/métodos , Artéria Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Volume Sanguíneo/fisiologia , Feminino , Artéria Hepática/fisiopatologia , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Microesferas , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA