Resultados 1 - 20 de 116
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Respir Res ; 25(1): 179, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664685

RESUMO

BACKGROUND: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS: This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS: EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION: EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.


Assuntos
Impedância Elétrica , Tomografia , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia/métodos , Monitorização Fisiológica/métodos , Adulto , Respiração Artificial/métodos , Respiração , Idoso de 80 Anos ou mais , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiologia
2.
Crit Care ; 28(1): 194, 2024 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-38849936

RESUMO

BACKGROUND: The spontaneous breathing trial (SBT) technique that best balance successful extubation with the risk for reintubation is unknown. We sought to determine the comparative efficacy and safety of alternative SBT techniques. METHODS: We searched Medline, EMBASE, and the Cochrane Central Register of Controlled Trials from inception to February 2023 for randomized or quasi-randomized trials comparing SBT techniques in critically ill adults and children and reported initial SBT success, successful extubation, reintubation (primary outcomes) and mortality (ICU, hospital, most protracted; secondary outcome) rates. Two reviewers screened, reviewed full-texts, and abstracted data. We performed frequentist random-effects network meta-analysis. RESULTS: We included 40 RCTs (6716 patients). Pressure Support (PS) versus T-piece SBTs was the most common comparison. Initial successful SBT rates were increased with PS [risk ratio (RR) 1.08, 95% confidence interval (CI) (1.05-1.11)], PS/automatic tube compensation (ATC) [1.12 (1.01 -1.25), high flow nasal cannulae (HFNC) [1.07 (1.00-1.13) (all moderate certainty), and ATC [RR 1.11, (1.03-1.20); low certainty] SBTs compared to T-piece SBTs. Similarly, initial successful SBT rates were increased with PS, ATC, and PS/ATC SBTs compared to continuous positive airway pressure (CPAP) SBTs. Successful extubation rates were increased with PS [RR 1.06, (1.03-1.09); high certainty], ATC [RR 1.13, (1.05-1.21); moderate certainty], and HFNC [RR 1.06, (1.02-1.11); high certainty] SBTs, compared to T-piece SBTs. There was little to no difference in reintubation rates with PS (vs. T-piece) SBTs [RR 1.05, (0.91-1.21); low certainty], but increased reintubation rates with PS [RR 2.84, (1.61-5.03); moderate certainty] and ATC [RR 2.95 (1.57-5.56); moderate certainty] SBTs compared to HFNC SBTs. CONCLUSIONS: SBTs conducted with pressure augmentation (PS, ATC, PS/ATC) versus without (T-piece, CPAP) increased initial successful SBT and successful extubation rates. Although SBTs conducted with PS or ATC versus HFNC increased reintubation rates, this was not the case for PS versus T-piece SBTs.


Assuntos
Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Extubação/métodos , Extubação/estatística & dados numéricos , Desmame do Respirador/métodos , Desmame do Respirador/estatística & dados numéricos , Desmame do Respirador/normas
3.
BMC Anesthesiol ; 24(1): 227, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982350

RESUMO

PURPOSE: We aimed to evaluate the ability of the peripheral perfusion index (PPI) to predict reintubation of critically ill surgical patients. METHODS: This prospective observational study included mechanically ventilated adults who were extubated after a successful spontaneous breathing trial (SBT). The patients were followed up for the next 48 h for the need for reintubation. The heart rate, systolic blood pressure, respiratory rate, peripheral arterial oxygen saturation (SpO2), and PPI were measured before-, at the end of SBT, 1 and 2 h postextubation. The primary outcome was the ability of PPI 1 h postextubation to predict reintubation using area under the receiver operating characteristic curve (AUC) analysis. Univariate and multivariate analyses were performed to identify predictors for reintubation. RESULTS: Data from 62 patients were analysed. Reintubation occurred in 12/62 (19%) of the patients. Reintubated patients had higher heart rate and respiratory rate; and lower SpO2 and PPI than successfully weaned patients. The AUC (95%confidence interval) for the ability of PPI at 1 h postextubation to predict reintubation was 0.82 (0.71-0.91) with a negative predictive value of 97%, at a cutoff value of ≤ 2.5. Low PPI and high respiratory rate were the independent predictors for reintubation. CONCLUSION: PPI early after extubation is a useful tool for prediction of reintubation. Low PPI is an independent risk factor for reintubation. A PPI > 2.5, one hour after extubation can confirm successful extubation.


Assuntos
Estado Terminal , Intubação Intratraqueal , Índice de Perfusão , Humanos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Intubação Intratraqueal/métodos , Idoso , Extubação/métodos , Frequência Cardíaca/fisiologia , Saturação de Oxigênio/fisiologia , Respiração Artificial/métodos , Taxa Respiratória/fisiologia , Valor Preditivo dos Testes , Adulto
4.
Microvasc Res ; 148: 104552, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37207721

RESUMO

PURPOSE: This study assessed the association between changes in sublingual microcirculation after a spontaneous breathing trial (SBT) and successful extubation. MATERIALS AND METHODS: Sublingual microcirculation was assessed using an incident dark-field video microscope before and after each SBT and before extubation. Microcirculatory parameters before the SBT, at the end of the SBT, and before extubation were compared between the successful and failed extubation groups. RESULTS: Forty-seven patients were enrolled and analysed in this study (34 patients in the successful extubation group and 13 patients in the failed extubation group). At the end of the SBT, the weaning parameters did not differ between the two groups. However, the total small vessel density (21.2 [20.4-23.7] versus 24.9 [22.6-26.5] mm/mm2), perfused small vessel density (20.6 [18.5-21.8] versus 23.1 [20.9-25] mm/mm2), proportion of perfused small vessels (91 [87-96] versus 95 [93-98] %), and microvascular flow index (2.8 [2.7-2.9] versus 2.9 [2.9-3]) were significantly lower in the failed extubation group than in the successful extubation group. The weaning and microcirculatory parameters did not differ significantly between the two groups before the SBT. CONCLUSIONS: More patients are required to investigate the difference between baseline microcirculation before a successful SBT and the change in microcirculation at the end of the SBT between the successful and failed extubation groups. Better sublingual microcirculatory parameters at the end of SBT and before extubation are associated with successful extubation.


Assuntos
Extubação , Desmame do Respirador , Humanos , Microcirculação
5.
J Intensive Care Med ; 38(6): 529-533, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36648173

RESUMO

INTRODUCTION: Many patients who pass a spontaneous awakening trial (SAT) and spontaneous breathing trial (SBT) do not undergo extubation that day. We aimed to identify predictors of extubation on the day of passing an SBT and to develop prediction models for extubation among mechanically ventilated patients. METHODS: In a cohort of mechanically ventilated patients who had passed an SBT in a single, academic medical intensive care unit (ICU) from 2018 to 2019, we developed a logistic regression model for identifying predictors of extubation. RESULTS: Of 745 patients in our study, 77% were extubated the day they passed a SBT. Independent predictors of extubation included higher Richmond Agitation Sedation Scale (RASS) (-2 compared to -4: odds ratio (OR) 1.83, 95% confidence interval (CI) 1.56 to 2.14), receipt of sedation on the day prior (OR 2.12, 95% CI 1.63 to 2.74), absence of diagnosis of sepsis or septic shock (OR 0.77, 95% CI 0.59 to 1), absence of neurological illness (OR 0.59, 95% CI 0.37 to 0.96), indication for intubation of altered mental status, seizure, or agitation (OR 1.67, 95% CI 1.05 to 2.65), and absence of hemodynamic instability or cardiac arrest (OR 0.67, 95% CI 0.47 to 0.95). CONCLUSION AND RELEVANCE: Patients on mechanical ventilation were more likely to be extubated on the day they passed an SBT if they had higher RASS scores, received sedation the day prior, or did not have diagnosis of sepsis, neurological illness, or hemodynamic instability. Future research should attempt to identify and address modifiable risk factors for failure to extubate after passing an SBT.


Assuntos
Estado Terminal , Sepse , Adulto , Humanos , Extubação , Estado Terminal/terapia , Unidades de Terapia Intensiva , Respiração Artificial , Desmame do Respirador
6.
J Intensive Care Med ; 38(3): 299-306, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35934953

RESUMO

BACKGROUND: Preclinical studies suggest that ketamine stimulates breathing. We investigated whether adding a ketamine infusion at low and high doses to propofol sedation improves inspiratory flow and enhances sedation in spontaneously breathing critically ill patients. METHODS: In this prospective interventional study, twelve intubated, spontaneously breathing patients received ketamine infusions at 5 mcg/kg/min, followed by 10 mcg/kg/min for 1 h each. Airway flow, pressure, and esophageal pressure were recorded during a spontaneous breathing trial (SBT) at baseline, and during the SBT conducted at the end of each ketamine infusion regimen. SBT consisted of one-minute breathing with zero end-expiratory pressure and no pressure support. Changes in inspiratory flow at the pre-specified time points were assessed as the primary outcome. Ketamine-induced change in beta-gamma electroencephalogram power was the key secondary endpoint. We also analyzed changes in other ventilatory parameters respiratory timing, and resistive and elastic inspiratory work of breathing. RESULTS: Ketamine infusion of 5 and 10 mcg/kg/min increased inspiratory flow (median, IQR) from 0.36 (0.29-0.46) L/s at baseline to 0.47 (0.32-0.57) L/s and 0.44 (0.33-0.58) L/s, respectively (p = .013). Resistive work of breathing decreased from 0.4 (0.1-0.6) J/l at baseline to 0.2 (0.1-0.3) J/l after ketamine 10 mcg/kg/min (p = .042), while elastic work of breathing remained unchanged. Electroencephalogram beta-gamma power (19-44 Hz) increased compared to baseline (p < .01). CONCLUSIONS: In intubated, spontaneously breathing patients receiving a constant rate of propofol, ketamine increased inspiratory flow, reduced inspiratory work of breathing, and was associated with an "activated" electroencephalographic pattern. These characteristics might facilitate weaning from mechanical ventilation.


Assuntos
Ketamina , Propofol , Humanos , Estudos Prospectivos , Respiração Artificial , Desmame do Respirador , Trabalho Respiratório , Unidades de Terapia Intensiva
7.
Neurocrit Care ; 38(1): 105-117, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36450970

RESUMO

BACKGROUND: Alterations in perfusion to the brain during the transition from mechanical ventilation (MV) to a spontaneous breathing trial (SBT) remain poorly understood. The aim of the study was to determine whether changes in cerebral cortex perfusion, oxygen delivery (DO2), and oxygen saturation (%StiO2) during the transition from MV to an SBT differ between patients who succeed or fail an SBT. METHODS: This was a single-center prospective observational study conducted in a 16-bed medical intensive care unit of the University Hospital Leuven, Belgium. Measurements were performed in 24 patients receiving MV immediately before and at the end of a 30-min SBT. Blood flow index (BFI), DO2, and %StiO2 in the prefrontal cortex, scalene, rectus abdominis, and thenar muscle were simultaneously assessed by near-infrared spectroscopy using the tracer indocyanine green dye. Cardiac output, arterial blood gases, and systemic oxygenation were also recorded. RESULTS: During the SBT, prefrontal cortex BFI and DO2 responses did not differ between SBT-failure and SBT-success groups (p > 0.05). However, prefrontal cortex %StiO2 decreased in six of eight patients (75%) in the SBT-failure group (median [interquartile range 25-75%]: MV = 57.2% [49.1-61.7] vs. SBT = 51.0% [41.5-62.5]) compared to 3 of 16 patients (19%) in the SBT-success group (median [interquartile range 25-75%]: MV = 65.0% [58.6-68.5] vs. SBT = 65.1% [59.5-71.1]), resulting in a significant differential %StiO2 response between groups (p = 0.031). Similarly, a significant differential response in thenar muscle %StiO2 (p = 0.018) was observed between groups. A receiver operating characteristic analysis identified a decrease in prefrontal cortex %StiO2 > 1.6% during the SBT as an optimal cutoff, with a sensitivity of 94% and a specificity of 75% to predict SBT failure and an area under the curve of 0.79 (95% CI: 0.55-1.00). Cardiac output, systemic oxygenation, scalene, and rectus abdominis BFI, DO2, and %StiO2 responses did not differ between groups (p > 0.05); however, during the SBT, a significant positive association in prefrontal cortex BFI and partial pressure of arterial carbon dioxide was observed only in the SBT-success group (SBT success: Spearman's ρ = 0.728, p = 0.002 vs. SBT failure: ρ = 0.048, p = 0.934). CONCLUSIONS: This study demonstrated a reduced differential response in prefrontal cortex %StiO2 in the SBT-failure group compared with the SBT-success group possibly due to the insufficient increase in prefrontal cortex perfusion in SBT-failure patients. A > 1.6% drop in prefrontal cortex %StiO2 during SBT was sensitive in predicting SBT failure. Further research is needed to validate these findings in a larger population and to evaluate whether cerebral cortex %StiO2 measurements by near-infrared spectroscopy can assist in the decision-making process on liberation from MV.


Assuntos
Saturação de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Respiração Artificial , Perfusão , Córtex Cerebral/diagnóstico por imagem , Oxigênio
8.
Indian J Crit Care Med ; 27(8): 597-598, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37636850

RESUMO

How to cite this article: Rajbanshi LK. Author Reply "Comment on Prediction of Successful Spontaneous Breathing Trial and Extubation of Trachea by Lung Ultrasound in Mechanically Ventilated Patients in Intensive Care". Indian J Crit Care Med 2023;27(8):597-598.

9.
Indian J Crit Care Med ; 27(11): 857-858, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37936801

RESUMO

How to cite this article: Rajbanshi LK, Bajracharya A, Devkota D. Author Reply-lung Ultrasound Score-Does It Really Predict Extubation Failure? Indian J Crit Care Med 2023;27(11):857-858.

10.
Indian J Crit Care Med ; 27(7): 482-487, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37502293

RESUMO

Introduction: Spontaneous breathing trial (SBT) is always successful in mechanically ventilated patients. This study was conducted to assess the prediction of successful SBT and extubation of trachea by bedside lung ultrasound in mechanically ventilated patients. Methodology: This was a prospective observational study for 1 year conducted at a tertiary teaching hospital ICU on 102 patients with age more than 18 years and who were mechanically ventilated for more than 24 hours. Bedside lung ultrasound was used to assess the lung ultrasound score (LUS) and lung profiles in patients who clinically met the criteria for SBT. The LUS at the beginning of SBT and 30 minutes after SBT were used to predict the successful SBT and tracheal extubation. Result: Spontaneous breathing trial and tracheal extubation were successful in 73 (71.6%) and 57 (55.8%) of the patients. The AUC for lung ultrasound in predicting successful SBT at the beginning and 30 minutes of SBT were 0.781 (CI 95% 0.674-0.888, p < 0.001) and 0.841 (CI 95% 0.742-0.941, p < 0.001) with a cut-off value of 17.5 and 19.5, respectively. Similarly, AUC for LUS in relation to tracheal extubation was 0.786 (CI 95% 0.694-0.879, p < 0.001) and 0.841(CI 95% 0.756-0.925, p < 0.001) at 0 and 30 minutes. About 57.5% of the patients with A profiles tolerated successful SBT while 48.3% of the patients having C profile had failed SBT (p < 0.001). COPD, lung ultrasound, higher SOFA score, and longer duration of mechanical ventilation had a statistically significant negative correlation with successful SBT. Conclusion: Lower LUS and A profiles lung ultrasound are associated with more successful weaning and tracheal extubation in mechanically ventilated patients. How to cite this article: Rajbanshi LK, Bajracharya A, Devkota D. Prediction of Successful Spontaneous Breathing Trial and Extubation of Trachea by Lung Ultrasound in Mechanically Ventilated Patients in Intensive Care Unit. Indian J Crit Care Med 2023;27(7):482-487.

11.
Indian J Crit Care Med ; 27(10): 695-696, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37908418

RESUMO

How to cite this article: Havaldar AA, Krishna B. Wean to Win. Indian J Crit Care Med 2023;27(10):695-696.

12.
Respir Res ; 23(1): 22, 2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35130914

RESUMO

BACKGROUND: Recent guidelines recommended conducting spontaneous breathing trial (SBT) with modest inspiratory pressure augmentation rather than T-piece or continuous positive airway pressure. However, it was based on few studies focused on the outcomes of extubation rather than the weaning process, despite the existence of various weaning situations in clinical practice. This study was designed to investigate the effects of SBT with pressure support ventilation (PSV) or T-piece on weaning outcomes. METHODS: All consecutive patients admitted to two medical intensive care units (ICUs) and those requiring mechanical ventilation (MV) for more than 24 h from November 1, 2017 to September 30, 2020 were prospectively registered. T-piece trial was used until March 2019, and then, pressure support of 8 cmH2O and 0 positive end-expiratory pressure were used for SBT since July 2019, after a 3-month transition period for the revised SBT protocol. The primary outcome of this study was successful weaning defined according to the WIND (Weaning according to a New Definition) definition and were compared between the T-piece group and PSV group. The association between the SBT method and weaning outcome was evaluated with logistic regression analysis. RESULTS: In this study, 787 eligible patients were divided into the T-piece (n = 473) and PSV (n = 314) groups after excluding patients for a 3-month transition period. Successful weaning was not different between the two groups (85.0% vs. 86.3%; p = 0.607). However, the PSV group had a higher proportion of short weaning (70.1% vs. 59.0%; p = 0.002) and lower proportion of difficult weaning (13.1% vs. 24.1%; p < 0.001) than the T-piece group. The proportion of prolonged weaning was similar between the two groups (16.9% vs. 16.9%; p = 0.990). After excluding patients who underwent tracheostomy before the SBTs, similar results were found. Reintubation rates at 48 h, 72 h, and 7 days following the planned extubation were not different between the PSV and T-piece groups. Moreover, no significant differences in intensive care unit and hospital mortality and length of stay were observed. CONCLUSIONS: In critically ill medical patients, SBT using PSV was not associated with a higher rate of successful weaning compared with SBT using T-piece. However, PSV could shorten the weaning process without increasing the risk of reintubation.


Assuntos
Estado Terminal/terapia , Unidades de Terapia Intensiva , Respiração com Pressão Positiva/métodos , Desmame do Respirador/métodos , Idoso , Extubação , Estado Terminal/epidemiologia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Crit Care ; 26(1): 402, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564808

RESUMO

BACKGROUND: A spontaneous breathing trial (SBT) is used to determine whether patients are ready for extubation, but the best method for choosing the SBT strategy remains controversial. We investigated the effect of high-flow oxygen versus T-piece ventilation strategies during SBT on rates of weaning failure among patients receiving mechanical ventilation. METHODS: This randomized clinical trial was conducted from June 2019 through January 2022 among patients receiving mechanical ventilation for ≥ 12 h who fulfilled the weaning readiness criteria at a single-center medical intensive care unit. Patients were randomized to undergo either T-piece SBT or high-flow oxygen SBT. The primary outcome was weaning failure on day 2, and the secondary outcomes were weaning failure on day 7, ICU and hospital length of stay, and ICU and in-hospital morality. RESULTS: Of 108 patients (mean age, 67.0 ± 11.1 years; 64.8% men), 54 received T-piece SBT and 54 received high-flow oxygen SBT. Weaning failure on day 2 occurred in 5 patients (9.3%) in the T-piece group and 3 patients (5.6%) in the high-flow group (difference, 3.7% [95% CI, - 6.1-13.6]; p = 0.713). Weaning failure on day 7 occurred in 13 patients (24.1%) in the T-piece group and 7 patients (13.0%) in the high-flow group (difference, 11.1% [95% CI, - 3.4-25.6]; p = 0.215). A post hoc subgroup analysis showed that high-flow oxygen SBT was significantly associated with a lower rate of weaning failure on day 7 (OR, 0.17 [95% CI, 0.04-0.78]) among those patients intubated because of respiratory failure (p for interaction = 0.020). The ICU and hospital length of stay and mortality rates did not differ significantly between the two groups. During the study, no serious adverse events were recorded. CONCLUSIONS: Among patients receiving mechanical ventilation, high-flow oxygen SBT did not significantly reduce the risk of weaning failure compared with T-piece SBT. However, the study may have been underpowered to detect a clinically important treatment effect for the comparison of high-flow oxygen SBT versus T-piece SBT, and a higher percentage of patients with simple weaning and a lower weaning failure rate than expected should be considered when interpreting the findings. Clinical trial registration This trial was registered with ClinicalTrials.gov (number NCT03929328) on April 26, 2019.


Assuntos
Oxigênio , Respiração Artificial , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Respiração Artificial/métodos , Oxigênio/uso terapêutico , Desmame do Respirador/métodos , Respiração , Pulmão , Extubação/métodos
14.
Crit Care ; 26(1): 162, 2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35668459

RESUMO

BACKGROUND: Whether dyspnea is present before starting a spontaneous breathing trial (SBT) and whether it may affect the outcome of the SBT is unknown. Mechanical Ventilation-Respiratory Distress Observation Scale (MV-RDOS) has been proposed as a reliable surrogate of dyspnea in non-communicative intubated patients. In the present study, we sought (1) to describe the evolution of the MV-RDOS during a SBT and (2) to investigate whether MV-RDOS can predict the outcome of the SBT. METHODS: Prospective, single-center study in a twenty-two bed ICU in a tertiary center. Patients intubated since more 48 h who had failed a first SBT were eligible if they meet classical readiness to wean criteria. The MV-RDOS was assessed before, at 2-min, 15-min and 30-min (end) of the SBT. The presence of clinically important dyspnea was inferred by a MV-RDOS value ≥ 2.6. RESULTS: Fifty-eight patients (age 63 [51-70], SAPS II 66 [51-76]; med [IQR]) were included. Thirty-three (57%) patients failed the SBT, whose 18 (55%) failed before 15-min. Twenty-five (43%) patients successfully passed the SBT. A MV-RDOS ≥ 2.6 was present in ten (17%) patients before to start the SBT. All these ten patients subsequently failed the SBT. A MV-RDOS ≥ 2.6 at 2-min predicted a SBT failure with a 51% sensibility and a 88% specificity (AUC 0.741 95% confidence interval [CI] 0.616-0.866, p = 0.002). Best cut-off value at 2-min was 4.3 and predicted SBT failure with a 27% sensibility and a 96% specificity. CONCLUSION: Despite patients met classical readiness to wean criteria, respiratory distress assessed with the MV-RDOS was frequent at the beginning of SBT. Measuring MV-RDOS before to initiate a SBT could avoid undue procedure and reduce patient's exposure to unnecessary mechanical ventilation weaning failure and distress.


Assuntos
Síndrome do Desconforto Respiratório , Desmame do Respirador , Dispneia/diagnóstico , Dispneia/etiologia , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial , Desmame do Respirador/métodos
15.
J Intensive Care Med ; 37(11): 1417-1425, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35815895

RESUMO

Since the inception of critical care medicine and artificial ventilation, literature and research on weaning has transformed daily patient care in intensive care units (ICU). As our knowledge of mechanical ventilation (MV) improved, so did the need to study patient-ventilator interactions and weaning predictors. Randomized trials have evaluated the use of protocol-based weaning (vs. usual care) to study the duration of MV in ICUs, different techniques to conduct spontaneous breathing trials (SBT), and strategies to eventually extubate a patient whose initial SBT failed. Despite considerable milestones in the management of multiple diseases contributing to reversible respiratory failure, in the application of early rehabilitative interventions to preserve muscle integrity, and in ventilator technology that mitigates against ventilator injury and dyssynchrony, major barriers to successful liberation from MV persist. This review provides a broad encompassing view of weaning classification, causes of weaning failure, and evidence behind weaning predictors and weaning modes.


Assuntos
Insuficiência Respiratória , Desmame do Respirador , Humanos , Unidades de Terapia Intensiva , Respiração Artificial/métodos , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Desmame do Respirador/métodos , Ventiladores Mecânicos
16.
J Intensive Care Med ; 37(3): 337-341, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33461374

RESUMO

OBJECTIVE: Weaning parameters are well studied in patients undergoing first time extubation. Fewer data exists to guide re-extubation of patients who failed their first extubation attempt. It is reasonable to postulate that improved weaning parameters between the first and second extubation attempt would lead to improved rates of re-extubation success. To investigate, we studied a cohort of patients who failed their first extubation attempt and underwent a second attempt at extubation. We hypothesized that improvement in weaning parameters between the first and the second extubation attempt is associated with successful reextubation. INTERVENTIONS: Rapid shallow breathing index (RSBI), maximum inspiratory pressure (MIP), vital capacity (VC), and the blood partial pressure of CO2 (PaCO2) were measured and recorded in the medical record prior to extubation along with demographic information. We examined the relationship between the change in extubation and re-extubation weaning parameters and re-extubation success. MEASUREMENTS AND MAIN RESULTS: A total of 1283 adult patients were included. All weaning parameters obtained prior to re-extubation differed between those who were successful and those who required a second reintubation. Those with reextubation success had slightly lower PaCO2 values (39.5 ± 7.4 mmHg vs. 41.6 ± 9.1 mmHg, p = 0.0045) and about 13% higher vital capacity volumes (1021 ± 410 mL vs. 907 ± 396 mL, p = 0.0093). Lower values for RSBI (53 ± 32 breaths/min/L vs. 69 ± 42 breaths/min/L, p < 0.001) and MIP (-41 ± 12 cmH2O vs. -38 ± 13 cm H2O), p = 0.0225) were seen in those with re-extubation success. Multivariable logistical regression demonstrates lack of independent associated between the change in parameters between the 2 attempts and re-extubation success. CONCLUSIONS: The relationship between the changes in extubation parameters through successive attempts is driven primarily by the value obtained immediately prior to re-extubation. These findings do not support waiting for an improvement in extubation parameters to extubate patients who failed a first attempt at extubation if extubation parameters are compatible with success.


Assuntos
Extubação , Desmame do Respirador , Adulto , Humanos , Intubação Intratraqueal , Respiração Artificial , Desmame
17.
BMC Pulm Med ; 22(1): 337, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36071420

RESUMO

BACKGROUND: The optimum timing to wean is crucial to avoid negative outcomes for mechanically ventilated patients. The rapid shallow breathing index (RSBI), a widely used weaning index, has limitations in predicting weaning outcomes. By replacing the tidal volume of the RSBI with diaphragmatic excursion (DE) and diaphragm thickening fraction (DTF) assessed by ultrasonography, we calculated two weaning indices, the diaphragmatic excursion rapid shallow breathing index (DE-RSBI, respiratory rate [RR]/DE) and the diaphragm thickening fraction rapid shallow breathing index (DTF-RSBI, RR/DTF). The aim of this study was to evaluate the predictive values of DTF-RSBI, DE-RSBI and traditional RSBI in weaning failure. METHODS: This prospective observational study included patients undergoing mechanical ventilation (MV) for > 48 h and who were readied for weaning. During a pressure support ventilation (PSV) spontaneous breathing trial (SBT), right hemidiaphragmatic excursion and DTF were measured by bedside ultrasonography as well as RSBI. Weaning failure was defined as: (1) failing the SBT and (2) SBT success but inability to maintain spontaneous breathing for more than 48 h without noninvasive or invasive ventilation. A receiver operator characteristic (ROC) curve was used for analyzing the diagnostic accuracy of RSBI, DE-RSBI, and DTF-RSBI. RESULTS: Of the 110 patients studied, 37 patients (33.6%) failed weaning. The area under the ROC (AUROC) curves for RSBI, DE-RSBI, and DTF-RSBI for predicting failed weaning were 0.639, 0.813, and 0.859, respectively. The AUROC curves for DE-RSBI and DTF-RSBI were significantly higher than for RSBI (P = 0.004 and P < 0.001, respectively). The best cut-off values for predicting failed weaning were RSBI > 51.2 breaths/min/L, DE-RSBI > 1.38 breaths/min/mm, and DTF-RSBI > 78.1 breaths/min/%. CONCLUSIONS: In this study, two weaning indices determined by bedside ultrasonography, the DE-RSBI (RR/DE) and DTF-RSBI (RR/DTF), were shown to be more accurate than the traditional RSBI (RR/VT) in predicting weaning outcome during a PSV SBT.


Assuntos
Diafragma , Desmame do Respirador , Diafragma/diagnóstico por imagem , Humanos , Respiração , Respiração Artificial , Ultrassonografia
18.
BMC Emerg Med ; 22(1): 112, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35729524

RESUMO

OBJECTIVE: To evaluate how spontaneous breathing trial (SBT) affects successful extubation and prognosis in acute exacerbation of chronic obstructive pulmonary disease (AECOPD) patients under mechanical ventilation. METHODS: AECOPD patients under invasive mechanical ventilation were recruited into the study and divided into the SBT and non-SBT groups. SBT patients received SBT for 60 min before extubation, while non-SBT patients that met weaning criteria were immediately extubated without SBT. RESULTS: A total of 64 patients were enrolled in analysis, including 32 in SBT group and 32 in non-SBT group. Patients in the two groups had similar baseline demographics and clinical characteristics (all parameters: p = > 0.05). Four (12.5%) patients in the SBT group and 5 (15.6%) in the non-SBT group were reintubated in 48 h of extubation (p = 0.821). During the 28-day follow-up after extubation, 3 patients died, 1 (3.1%) in the SBT group and 2 (6.3%) in the non-SBT group (p = 0.554). CONCLUSION: Our findings indicate that SBT did not affect extubation success, in-hospital mortality, and 28-day survival in AECOPD patients under mechanical ventilation.


Assuntos
Extubação , Doença Pulmonar Obstrutiva Crônica , Humanos , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/terapia , Respiração Artificial , Desmame do Respirador
19.
Indian J Crit Care Med ; 26(2): 246-247, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35712728

RESUMO

Catheter mounts with swivel connectors are used to attach the endotracheal tube to the ventilator circuit, dampening jerks and drags and increasing patient comfort. We suggest a unique application of catheter mount as T-piece for weaning, eliminating the need for a single inventory purchase and repurposing a previously used item for a new use, lowering the financial burden on patients. In our ICU, catheter mounts are being used as an alternative to T-piece for 30-minute weaning trials following successful SBT trials to evaluate patients' response to Zero PEEP (ZEEP) and therefore the probable occurrence of alveolar derecruitment to decrease extubation failure. How to cite this article: Anand A, Panda R, Kodamanchili S, Saigal S, Gowthaman TB, Bhardwaj K. Novel Use of Catheter Mount as an Alternative to T-piece. Indian J Crit Care Med 2022;26(2):246-247.

20.
Crit Care ; 25(1): 280, 2021 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-34353348

RESUMO

The respiratory system reacts instantaneously to intrinsic and extrinsic inputs. This adaptability results in significant fluctuations in breathing parameters, such as respiratory rate, tidal volume, and inspiratory flow profiles. Breathing variability is influenced by several conditions, including sleep, various pulmonary diseases, hypoxia, and anxiety disorders. Recent studies have suggested that weaning failure during mechanical ventilation may be predicted by low respiratory variability. This review describes methods for quantifying breathing variability, summarises the conditions and comorbidities that affect breathing variability, and discusses the potential implications of breathing variability for anaesthesia and intensive care.


Assuntos
Anestesiologia/tendências , Cuidados Críticos/tendências , Mecânica Respiratória/fisiologia , Manuseio das Vias Aéreas/métodos , Manuseio das Vias Aéreas/normas , Anestesiologia/métodos , Cuidados Críticos/métodos , Humanos , Respiração Artificial/métodos , Estudos de Tempo e Movimento
SELEÇÃO DE REFERÊNCIAS