Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 735
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(15): e2213987120, 2023 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-37011196

RESUMO

The dinosaur-bird transition involved several anatomical, biomechanical, and physiological modifications of the theropod bauplan. Non-avian maniraptoran theropods, such as Troodon, are key to better understand changes in thermophysiology and reproduction occurring during this transition. Here, we applied dual clumped isotope (Δ47 and Δ48) thermometry, a technique that resolves mineralization temperature and other nonthermal information recorded in carbonates, to eggshells from Troodon, modern reptiles, and modern birds. Troodon eggshells show variable temperatures, namely 42 and 29 ± 2 °C, supporting the hypothesis of an endothermic thermophysiology with a heterothermic strategy for this extinct taxon. Dual clumped isotope data also reveal physiological differences in the reproductive systems between Troodon, reptiles, and birds. Troodon and modern reptiles mineralize their eggshells indistinguishable from dual clumped isotope equilibrium, while birds precipitate eggshells characterized by a positive disequilibrium offset in Δ48. Analyses of inorganic calcites suggest that the observed disequilibrium pattern in birds is linked to an amorphous calcium carbonate (ACC) precursor, a carbonate phase known to accelerate eggshell formation in birds. Lack of disequilibrium patterns in reptile and Troodon eggshells implies these vertebrates had not acquired the fast, ACC-based eggshell calcification process characteristic of birds. Observation that Troodon retained a slow reptile-like calcification suggests that it possessed two functional ovaries and was limited in the number of eggs it could produce; thus its large clutches would have been laid by several females. Dual clumped isotope analysis of eggshells of extinct vertebrates sheds light on physiological information otherwise inaccessible in the fossil record.


Assuntos
Casca de Ovo , Répteis , Animais , Feminino , Carbonato de Cálcio , Isótopos
2.
Nano Lett ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38981024

RESUMO

Cryogenic temperatures are crucial for the operation of semiconductor quantum electronic devices, yet the heating effects induced by microwave or laser signals used for quantum state manipulation can lead to significant temperature variations at the nanoscale. Therefore, probing the temperature of individual devices in working conditions and understanding the thermodynamics are paramount for designing and operating large-scale quantum computing systems. In this study, we demonstrate high-sensitivity fast thermometry in a silicon nanotransistor at cryogenic temperatures using RF reflectometry. Through this method, we explore the thermodynamic processes of the nanotransistor during and after a laser pulse and determine the dominant heat dissipation channels in the few-kelvin temperature range. These insights are important to understand thermal budgets in quantum circuits, with our techniques being compatible with microwave and laser radiation, offering a versatile approach for studying other quantum electronic devices in working conditions.

3.
Nano Lett ; 24(23): 7048-7054, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38813994

RESUMO

High-resolution thermometry is critical for probing nanoscale energy transport. Here, we demonstrate how high-resolution thermometry can be accomplished using vanadium oxide (VOx), which features a sizable temperature-dependence of its resistance at room temperature and an even stronger dependence at its metal-insulator-transition (MIT) temperature. We microfabricate VOx nanofilm-based electrical resistance thermometers that undergo a metal-insulator-transition at ∼337 K and systematically quantify their temperature-dependent resistance, noise characteristics, and temperature resolution. We show that VOx sensors can achieve, in a bandwidth of ∼16 mHz, a temperature resolution of ∼5 µK at room temperature (∼300 K) and a temperature resolution of ∼1 µK at the MIT (∼337 K) when the amplitude of temperature perturbations is in the microkelvin range, which, in contrast to larger perturbations, is found to avoid hysteric resistance responses. These results demonstrate that VOx-based thermometers offer a ∼10-50-fold improvement in resolution over widely used Pt-based thermometers.

4.
Magn Reson Med ; 91(6): 2266-2277, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38181187

RESUMO

PURPOSE: A hybrid principal component analysis and projection onto dipole fields (PCA-PDF) MR thermometry motion compensation algorithm was optimized with atlas image augmentation and validated. METHODS: Experiments were conducted on a 3T Philips MRI and Profound V1 Sonalleve high intensity focused ultrasound (high intensity focused ultrasound system. An MR-compatible robot was configured to induce motion on custom gelatin phantoms. Trials with periodic and sporadic motion were introduced on phantoms while hyperthermia was administered. The PCA-PDF algorithm was augmented with a predictive atlas to better compensate for larger sporadic motion. RESULTS: During periodic motion, the temperature SD in the thermometry was improved from 1 . 1 ± 0 . 1 $$ 1.1\pm 0.1 $$ to 0 . 5 ± 0 . 1 ∘ $$ 0.5\pm 0.{1}^{\circ } $$ C with both the original and augmented PCA-PDF application. For large sporadic motion, the augmented atlas improved the motion compensation from the original PCA-PDF correction from 8 . 8 ± 0 . 5 $$ 8.8\pm 0.5 $$ to 0 . 7 ± 0 . 1 ∘ $$ 0.7\pm 0.{1}^{\circ } $$ C. CONCLUSION: The PCA-PDF algorithm improved temperature accuracy to <1°C during periodic motion, but was not able to adequately address sporadic motion. By augmenting the PCA-PDF algorithm, temperature SD during large sporadic motion was also reduced to <1°C, greatly improving the original PCA-PDF algorithm.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Hipertermia Induzida , Termometria , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Termometria/métodos , Imageamento por Ressonância Magnética/métodos , Temperatura , Hipertermia Induzida/métodos , Algoritmos
5.
Magn Reson Med ; 92(1): 15-27, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38501903

RESUMO

Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real-time, motion-robust, and volumetric MR thermometry. However, current technologies have inherent trade-offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting-edge MRI techniques for motion-robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion-robust MR thermometry strategies and inspire the development of motion-robust volumetric MR thermometry for practical use in clinics.


Assuntos
Imageamento por Ressonância Magnética , Movimento (Física) , Humanos , Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Termografia/métodos , Algoritmos , Hipertermia Induzida , Artefatos
6.
NMR Biomed ; 37(2): e5046, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37837254

RESUMO

Temperature is a hallmark parameter influencing almost all magnetic resonance properties (e.g., T1 , T2 , proton density, and diffusion). In the preclinical setting, temperature has a large influence on animal physiology (e.g., respiration rate, heart rate, metabolism, and oxidative stress) and needs to be carefully regulated, especially when the animal is under anesthesia and thermoregulation is disrupted. We present an open-source heating and cooling system capable of regulating the temperature of the animal. The system was designed using Peltier modules capable of heating or cooling a circulating water bath with active temperature feedback. Feedback was obtained using a commercial thermistor, placed in the animal rectum, and a proportional-integral-derivative controller was used to modulate the temperature. Its operation was demonstrated in a phantom as well as in mouse and rat animal models, where the standard deviation of the temperature of the animal upon convergence was less than a 10th of a degree. An application where brain temperature of a mouse was modulated was demonstrated using an invasive optical probe and noninvasive magnetic resonance spectroscopic thermometry measurements.


Assuntos
Calefação , Termometria , Ratos , Camundongos , Animais , Temperatura , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Temperatura Corporal , Termometria/métodos , Imagens de Fantasmas
7.
NMR Biomed ; : e5171, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38757603

RESUMO

Magnetic resonance spectroscopy (MRS) thermometry offers a noninvasive, localized method for estimating temperature by leveraging the temperature-dependent chemical shift of water relative to a temperature-stable reference metabolite under suitable calibration. Consequentially, this technique has significant potential as a tool for postmortem MR examinations in forensic medicine and pathology. In these examinations, the deceased are examined at a wide range of body temperatures, and MRS thermometry may be used for the temperature adjustment of magnetic resonance imaging (MRI) protocols or for corrections in the analysis of MRI or MRS data. However, it is not yet clear to what extent postmortem changes may influence temperature estimation with MRS thermometry. In addition, N-acetylaspartate, which is commonly used as an in vivo reference metabolite, is known to decrease with increasing postmortem interval (PMI). This study shows that lactate, which is not only present in significant amounts postmortem but also has a temperature-stable chemical shift, can serve as a suitable reference metabolite for postmortem MRS thermometry. Using lactate, temperature estimation in postmortem brain tissue of severed sheep heads was accurate up to 60 h after death, with a mean absolute error of less than 0.5°C. For this purpose, published calibrations intended for in vivo measurements were used. Although postmortem decomposition resulted in severe metabolic changes, no consistent deviations were observed between measurements with an MR-compatible temperature probe and MRS thermometry with lactate as a reference metabolite. In addition, MRS thermometry was applied to 84 deceased who underwent a MR examination as part of the legal examination. MRS thermometry provided plausible results of brain temperature in comparison with rectal temperature. Even for deceased with a PMI well above 60 h, MRS thermometry still provided reliable readings. The results show a good suitability of MRS thermometry for postmortem examinations in forensic medicine.

8.
Annu Rev Phys Chem ; 74: 521-545, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-36791779

RESUMO

Localized surface plasmon resonances (LSPRs) in metallic nanostructures result in subwavelength optical confinement that enhances light-matter interactions, for example, aiding the sensitivity of surface spectroscopies. The dissipation of surface plasmons as electronic and vibrational excitations sets the limit for field confinement but also provides opportunities for photochemistry, photocatalysis, and photothermal heating. Optimization for either goal requires a deeper understanding of this photothermalization process. In this review, we focus on recent insights into the physics and dynamics governing photothermalization of LSPRs in metallic nanostructures, emphasizing comparisons between the steady-state behavior and ultrafast time-resolved studies. The differences between these regimes inform how to best optimize plasmonic systems for applications under relatively low-intensity, continuous illumination (e.g., sunlight).

9.
Nanotechnology ; 35(29)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38604136

RESUMO

Remote thermal sensing has emerged as a temperature detection technique for tasks in which standard contact thermometers cannot be used due to environment or dimension limitations. One of such challenging tasks is the measurement of temperature in microelectronics. Here, optical thermometry using co-doped and mixed dual-center Gd2O3:Tb3+/Eu3+samples were realized. Ratiometric approach based on monitoring emission intensities of Tb3+(5D4-7F5) and Eu3+(5D0-7F2) transition provided sensing in the range of 30 °C-80 °C. Dispersion system type only slightly affected relative sensitivity, accuracy and precision. The applicability of phosphors synthesized to be utilized as remote optical thermometers for microelectronics has been proved with an example on a surface mount resistor and microcontroller.

10.
J Fluoresc ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954085

RESUMO

In the present study, the synthesis of BaSrSiO4 co-doped Yb3+ and Nd3+ nanophosphors (NPs) was successfully achieved through the conventional sol-gel method, as confirmed by X-ray diffraction and SEM analysis, verifying the formation of pure NPs. The FTIR and Raman spectra analysis confirm the formation of silicates, as different modes and vibrations of Si-O and Si-O-Si were seen at 800-1000 cm-1. The energy transfer (ET) mechanism between Nd3+ and Yb3+ ions was seen as the emission spectra showed a rise in intensity of one over another. PLE emission spectra showed transitions at 2F7/2-2F5/2 for Yb3+ and from 4F3/2 to (4I9/2, 4I11/2, and 4I13/2) for Nd3+ when excited at 785 nm. All the samples record low activation energy, which shows that the rate of reaction will be higher in all the samples, and it will be highest for 1 mol% Nd3+ and 1 mol% Yb3+. An increasing value of τ was seen with increasing Yb3+ concentration, which confirms the increase in the population of trap centers. The positron annihilation lifetime (PAL) curve showed that 1 mol% Yb3+ and 2 mol Nd3+ have single vacancies or shallower positron traps, whereas 3 mol% Yb3+ and 2 mol% Nd3+ have larger defects like surface oxygen vacancy clusters. The other two samples have balance vacancies, which makes them best for thermometry applications. The fluorescence intensity ratio (FIR) was calculated to get sensitivity for thermometry application. 2.13% K-1 sensitivity achieved at 303-333 K temperature.

11.
Epilepsy Behav ; 151: 109606, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38199054

RESUMO

Neuroinflammation (NI) is a key pathophysiological contributor to treatment-resistant epilepsy (TRE) that remains challenging to observe in vivo. Magnetic resonance spectroscopic imaging and thermometry (MRSI-t) is an emerging technique that can be used to non-invasively map brain temperature, whereby brain temperature elevations serve as a surrogate for the cellular and biochemical processes associated with NI. In a previous multimodal imaging study of focal epilepsy patients, we observed MRSI-t-based brain temperature elevations ipsilateral to the seizure onset zone (SOZ) that were concordant with evidence of edema (Sharma et al., 2023). Despite its potential as tool, it is unclear if MRSI-t can monitor changes in brain temperature in response to treatment. We imaged 25 participants approximately 12-weeks apart. Eight patients with TRE were imaged before receiving highly-purified pharmaceutical grade cannabidiol (CBD; pre-CBD) and after 12-weeks of CBD (on-CBD) therapy. Seventeen healthy controls (HCs) were also imaged twice. Repeated measures t-tests computed changes in TRE patients' seizure symptoms, mood, and brain temperature within their respective SOZs. Repeated measures ANOVAs tested Group*Time changes in imaging data. Participants with TRE had abnormally high peak brain temperatures within their SOZs that decreased after CBD initiation (p < 0.0001). Seizure severity scores also improved after CBD initiation (p < 0.001). These findings provide insights into the possible neural effects of CBD, and further demonstrate MRSI-t's potential as a tool for delineating SOZ. Further investigations into MRSI-t as a longitudinal measure of therapy-induced changes in NI are warranted.


Assuntos
Canabidiol , Epilepsia Resistente a Medicamentos , Epilepsia , Humanos , Canabidiol/farmacologia , Anticonvulsivantes , Temperatura , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/tratamento farmacológico , Epilepsia/tratamento farmacológico , Convulsões/diagnóstico , Encéfalo/diagnóstico por imagem
12.
Int J Hyperthermia ; 41(1): 2352545, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38991549

RESUMO

Magnetic resonance thermometry (MRT) can measure in-vivo 3D-temperature changes in real-time and noninvasively. However, for the oropharynx region and the entire head and neck, motion potentially introduces large artifacts. Considering long treatment times of 60-90 min, this study aims to evaluate whether MRT around the oropharynx is clinically feasible for hyperthermia treatments and quantify the effects of breathing and swallowing on MRT performance. A 3D-ME-FGRE sequence was used in a phantom cooling down and around the oropharynx of five volunteers over ∼75 min. The imaging protocol consisted of imaging with acceleration (ARC = 2), number of image averages (NEX = 1,2 and 3). For volunteers, the acquisitions included a breath-hold scan and scans with deliberate swallowing. MRT performance was quantified in neck muscle, spinal cord and masseter muscle, using mean average error (MAE), mean error (ME) and spatial standard deviation (SD). In phantom, an increase in NEX leads to a significant decrease in SD, but MAE and ME were unchanged. No significant difference was found in volunteers between the different scans. There was a significant difference between the regions evaluated: neck muscle had the best MAE (=1.96 °C) and SD (=0.82 °C), followed by spinal cord (MAE = 3.17 °C, SD = 0.92 °C) and masseter muscle (MAE = 4.53 °C, SD = 1.16 °C). Concerning the ME, spinal cord did best, then neck muscle and masseter muscle, with values of -0.64 °C, 1.15 °C and -3.05 °C respectively. Breathing, swallowing, and different ways of imaging (acceleration and NEX) do not significantly influence the MRT performance in the oropharynx region. The ROI selected however, leads to significant differences.


Assuntos
Imageamento por Ressonância Magnética , Orofaringe , Termometria , Humanos , Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Orofaringe/diagnóstico por imagem , Masculino , Adulto , Hipertermia Induzida/métodos , Feminino , Imagens de Fantasmas
13.
Vascular ; : 17085381241237494, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426388

RESUMO

OBJECTIVE: We hypothesized that the severity of foot poikilothermy can be used for better differentiation of grades of acute limb ischemia. Thus, the study aim was evaluation of the value of non-contact foot thermometry, performed using a low-cost infrared medical thermometer, as an adjunct for clinical diagnosis of immediately threatened acute limb ischemia. METHODS: It was a single-center observational prospective study performed over 3 years. Patients with acute limb ischemia of lower limbs grade I-IIB Rutherford treated with urgent revascularization were included. Grade of ischemia was determined independently by two experienced vascular surgeons. Thermometry of the ischemic foot was performed using a medical digital infrared non-contact thermometer (CK-T1501, Cooligg, China) with measuring accuracy of ±0.2°C. Temperature was measured in three points: the dorsal surface of the foot, plantar surface of the foot (both in the metatarsal region), and forehead. The maximal temperature gradient between patient's forehead and foot (∆Tmax F-F) was calculated. Measurements were repeated 6-12 h after revascularization. RESULTS: A total of 147 patients were included. Only 3 (2%) patients presented rest pain without sensory loss and motor deficit, while the majority were diagnosed with mild (63/147, 42.8%) or moderate (27/147, 18.3%) motor deficit. The temperature of the ischemic foot varied from 20 to 36.1°C, while median value of the temperature was 26.7 [24.5-29.9] °C on the dorsal surface and 26.8 [24.5-29.6] °C on the plantar surface of the foot (p = 0.85). Patients with Grade IIB ischemia had significantly lower dorsal foot temperature, plantar foot temperature, and larger ∆Tmax F-F than the patients with grades I-IIA: 25.1 [23.9-26.8] °C versus 29.9 [27.6-30.8] °C; 25.2 [23.8-27.5] °C versus 29.6 [28-31.1] °C; and 11.6 [9.7-12.8] °C versus 7.2 [6-9] °C (p < 0.0001). Areas under ROC curve for diagnosis of Grade IIB ischemia were similar for dorsal foot temperature (0.82), plantar temperature (0.81), and ∆Tmax F-F (0.82). The best cutoff value by Youden was ≥9.5°C for ∆Tmax F-F, ≤26.8°C for dorsal, and ≤27.7°C for plantar temperature. Criterion ∆Tmax F-F offered the highest specificity of 86% (95%CI 74.2-93.7) and positive predictive value of 89.2% (95%CI 79.5-93.2), while plantar temperature offered sensitivity of 82.5% (95%CI 70.1-91.3) and negative predictive value of 69.1% (95%CI 57.6-83.2). In multivariate analysis including age, gender, and etiology of arterial occlusion, the criterion ∆Tmax F-F of ≥9.5°C was a unique variable significantly associated with risk of amputation (adjusted OR 2.6, 95%CI 1.2-5.9, p = 0.01). CONCLUSION: Current study demonstrated that patients with immediately threatening ALI have significantly lower foot temperature than those with viable and marginally threatened limbs. Severe foot poikilothermy at admission is associated with poor outcomes of revascularization, mostly with limb loss.

14.
Luminescence ; 39(2): e4692, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38383694

RESUMO

An optical thermometry strategy based on Mn2+ -doped dual-wavelength emission phosphor has been reported. Samples with different doping content were synthesized through a high-temperature solid-phase method under an air atmosphere. The electronic structure of Li4 Zn(PO4 )2 was calculated using density functional theory, revealing it to be a direct band gap material with an energy gap of 4.708 eV. Moreover, the emitting bands of Mn2+ at 530 and 640 nm can be simultaneously observed when using 417 nm as the exciting wavelength. This is due to the occupation of Mn2+ at the Zn2+ site and the interstitial site. Further analysis was conducted on the temperature-dependent emission characteristics of the sample in the range 293-483 K. Mn2+ has different responses to temperature at different doping sites in Li4 Zn(PO4 )2 . Based on the calculations using the fluorescence intensity ratio technique, the maximum relative sensitivity at a temperature of 483 K was determined to be 1.69% K-1 , while the absolute sensitivity was found to be 0.12% K-1 . The results showed that the Li4 Zn(PO4 )2 :Mn2+ phosphor has potential application in optical thermometry.


Assuntos
Termometria , Temperatura , Íons , Lítio , Zinco
15.
J Emerg Med ; 66(3): e277-e283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336570

RESUMO

BACKGROUND: There is concern that the values provided by devices using infrared thermometry in emergency departments (EDs) do not reflect body core temperature accurately. OBJECTIVES: Evaluation of three thermometers commonly used in the ED. METHODS: Two infrared ear thermometers and an infrared forehead thermometer were evaluated using 1) the Voltcraft IRS-350 calibration device, 2) comparing temperature values to a rectal end-exercise temperature (T-RECT) of 38.1°C in 12 participants, and 3) comparing temperature values to rectal temperature in 133 ED patients. RESULTS: Calibration across the human core temperature range revealed that the ear thermometers underestimated radiant temperature by 0.77 ± 0.39°C and 1.84 ± 0.26°C, respectively, whereas the forehead thermometer overestimated radiant temperature by 0.90 ± 0.51°C. After cycling exercise, all thermometers underestimated T-RECT (0.54 ± 0.27°C and 1.03 ± 0.48°C for the ear thermometers and 1.14 ± 0.38°C for the forehead thermometer). In the ED, the ear thermometers underestimated T-RECT by 0.31 ± 0.37°C and 0.46 ± 0.50°C, whereas the forehead thermometer exhibited a nonsignificant overestimation of 0.04 ± 0.46°C. If the threshold for fever in all systems had been set to 37.5°C instead of 38.0°C, the sensitivity and specificity of the systems for real fever (T-RECT ≥ 38°C) are, respectively, 71% and 96% (ear thermometer 1), 57% and 97% (ear thermometer 2), and 86% and 90% (forehead thermometer). CONCLUSION: We conclude that the investigated thermometers are not reliable as devices to measure radiant temperature, cannot be used to assess body core temperature during exercise, but may be used as a screening device, with 37.5°C as a threshold for fever in emergency care settings.


Assuntos
Temperatura Corporal , Febre , Humanos , Temperatura , Febre/diagnóstico , Termômetros , Sensibilidade e Especificidade , Serviço Hospitalar de Emergência
16.
Sensors (Basel) ; 24(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38894332

RESUMO

The accuracy and efficacy of laser ablation procedures depend on the accurate placement of the laser applicator within the diseased tissue, monitoring the real-time temperature during the ablation procedure, and mapping the extent of the ablated region. Ultrasound (US) imaging has been widely used to guide ablation procedures. While US imaging offers significant advantages for guiding ablation procedures, its limitations include low imaging contrast, angular dependency, and limited ability to monitor the temperature. Photoacoustic (PA) imaging is a relatively new imaging modality that inherits the advantages of US imaging and offers enhanced capabilities for laser-guided ablations, such as accurate, angle-independent tracking of ablation catheters, the potential for quantitative thermometry, and monitoring thermal lesion formation. This work provides an overview of ultrasound-guided procedures and how different US-related artifacts limit their utility, followed by introducing PA as complementary to US as a solution to address the existing limitations and improve ablation outcomes. Furthermore, we highlight the integration of PA-driven features into existing US-guided laser ablation systems, along with their limitations and future outlooks. Integrated US/PA-guided laser ablation procedures can lead to safer and more precise treatment outcomes.


Assuntos
Terapia a Laser , Técnicas Fotoacústicas , Ultrassonografia , Técnicas Fotoacústicas/métodos , Terapia a Laser/métodos , Humanos , Ultrassonografia/métodos , Animais , Cirurgia Assistida por Computador/métodos
17.
Sensors (Basel) ; 24(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38610237

RESUMO

Multispectral thermometry is based on the law of blackbody radiation and is widely used in engineering practice today. Temperature values can be inferred from radiation intensity and multiple sets of wavelengths. Multispectral thermometry eliminates the requirements for single-spectral and spectral similarity, which are associated with two-colour thermometry. In the process of multispectral temperature inversion, the solution of spectral emissivity and multispectral data processing can be seen as the keys to accurate thermometry. At present, spectral emissivity is most commonly estimated using assumption models. When an assumption model closely matches an actual situation, the inversion of the temperature and the accuracy of spectral emissivity are both very high; however, when the two are not closely matched, the inversion result is very different from the actual situation. Assumption models of spectral emissivity exhibit drawbacks when used for thermometry of a complex material, or any material whose properties dynamically change during a combustion process. To address the above problems, in the present study, we developed a multispectral thermometry method based on optimisation ideas. This method involves analysing connections between measured temperatures of each channel in a multispectral temperature inversion process; it also makes use of correlations between multispectral signals at different temperatures. In short, we established a multivariate temperature difference correlation function based on the principles of multispectral radiometric thermometry, using information correlations between data for each channel in a temperature inversion process. We then established a high-precision thermometry model by optimising the correlation function and correcting any measurement errors. This method simplifies the modelling process so that it becomes an optimisation problem of the temperature difference function. This also removes the need to assume the relationships between spectral emissivity and other physical quantities, simplifying the process of multispectral thermometry. Finally, this involves correction of the spectral data so that any impact of measurement error on the thermometry is reduced. In order to verify the feasibility and reliability of the method, a simple eight-channel multispectral thermometry device was used for experimental validation, in which the temperature emitted from a blackbody furnace was identified as the standard value. In addition, spectral data from the 468-603 nm band were calibrated within a temperature range of 1923.15-2273.15 K, resulting in multispectral thermometry based on optimisation principles with an error rate of around 0.3% and a temperature calculation time of less than 3 s. The achieved level of inversion accuracy was better than that obtained using either a secondary measurement method (SMM) or a neural network method, and the calculation speed achieved was considerably faster than that obtained using the SMM method.

18.
Sensors (Basel) ; 24(11)2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38894194

RESUMO

Measuring temperature inside chemical reactors is crucial to ensuring process control and safety. However, conventional methods face a number of limitations, such as the invasiveness and the restricted dynamic range. This paper presents a novel approach using ultrasound transducers to enable accurate temperature measurements. Our experiments, conducted within a temperature range of 28.8 to 83.8 °C, reveal a minimal temperature accuracy of 98.6% within the critical zone spanning between 70.5 and 75 °C, and an accuracy of over 99% outside this critical zone. The experiments focused on a homogeneous environment of distilled water within a stainless-steel tank. This approach will be extended in a future research in order to diversify the experimental media and non-uniform environments, while promising broader applications in chemical process monitoring and control.

19.
Nano Lett ; 23(7): 2870-2876, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-36921149

RESUMO

The superlinear dependence of the reaction rate on the power of the excitation light, which may arise from both thermal and nonthermal effects, has been a hallmark of plasmon-driven photocatalysis on nanostructured metal surfaces. However, it remains challenging to distinguish and quantify the thermal and nonthermal effects because even slight uncertainties in measuring the local temperatures at the active surface sites may lead to significant errors in assessing thermal and nonthermal contributions to the overall reaction rates. Here we employ surface-enhanced Raman scattering as a surface-sensitive in situ spectroscopic tool to correlate detailed kinetic features of plasmon-mediated molecular transformations to the local temperatures at the active sites on photocatalyst surfaces. Our spectroscopic results clearly reveal that the superlinearity in the power dependence of the reaction rate observed in a plasmon-driven model reaction, specifically the reductive coupling of para-nitrothiophenol adsorbates on Ag nanoparticle surfaces, originates essentially from photothermal heating rather than nonthermal plasmonic effects.

20.
Molecules ; 29(13)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38998993

RESUMO

The thermal stability of oxyfluorotellurite glass systems, (65-x)TeO2-20ZnF2-12PbO-3Nb2O5-xPr2O3, doped with praseodymium was examined. The different concentrations of praseodymium oxide (x = 0.5 and 2 mol%) were applied to verify the thermal, optical and luminescence properties of the materials under study. The relatively high values of the Dietzel (ΔT) and Saad-Poulain (S or H') thermal stability factors determined using a differential thermal analysis (DTA) indicate the good thermal stability of the glass matrix, which gradually improves with the content of the active dopant. The temperature dependence of optical spectra in the temperature range 300-675 K for the VIS-NIR region was investigated. The involved Pr3+ optical transition intensities and relaxation dynamic of the praseodymium luminescent level were determined. The ultrashort femtosecond pulses were utilized to examine a dynamic relaxation of the praseodymium luminescent levels. Although the measured emission of the Pr3+ active ions in the studied glass encompasses the quite broad spectral region, the observed luminescence may only be attributed to 3PJ excited states. As a result, the observed decrease in the experimental lifetime for the 3P0 level along with the increasing activator content was identified as an intensification of the Pr-Pr interplay and the associated self-quenching process. The maximum relative sensitivities (Sr) estimated over a relatively wide temperature range are ~0.46% K-1 (at 300 K) for FIR (I530/I497) and 0.20% K-1 (at 600 K) for FIR (I630/I497), which seems to confirm the possibility of using investigated glasses in optical temperature sensors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA