RESUMO
BACKGROUND: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification. METHODS: In a randomized clinical trial, 220 patients with bicuspid aortic valve (43 women; 46±13 years of age) were included and treated with either 20 mg of atorvastatin per day or placebo for 3 years. Inclusion criteria were ≥18 years of age, nonsevere valvular dysfunction, nonsevere valve calcification, and ascending aorta diameter ≤50 mm. Computed tomography and echocardiography studies were performed at baseline and after 3 years of treatment. RESULTS: During follow-up, 28 patients (12.7%) discontinued medical treatment (15 on atorvastatin and 13 taking placebo). Thus, 192 patients completed the 36 months of treatment. Low-density lipoprotein cholesterol levels decreased significantly in the atorvastatin group (median [interquartile range], -30 mg/dL [-51.65 to -1.75 mg/dL] versus 6 mg/dL [-4, 22.5 mg/dL]; P<0.001). The maximum ascending aorta diameter increased with no differences between groups: 0.65 mm (95% CI, 0.45-0.85) in the atorvastatin group and 0.74 mm (95% CI, 0.45-1.04) in the placebo group (P=0.613). Similarly, no significant differences were found for the progression of the aortic valve calcium score (P=0.167) or valvular dysfunction. CONCLUSIONS: Among patients with bicuspid aortic valve without severe valvular dysfunction, atorvastatin treatment was not effective in reducing the progression of ascending aorta dilation and aortic valve calcification during 3 years of treatment despite a significant reduction in low-density lipoprotein cholesterol levels. REGISTRATION: URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2015-001808-57. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02679261.
Assuntos
Valva Aórtica , Atorvastatina , Doença da Válvula Aórtica Bicúspide , Calcinose , Progressão da Doença , Doenças das Valvas Cardíacas , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Atorvastatina/uso terapêutico , Feminino , Masculino , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/anormalidades , Valva Aórtica/efeitos dos fármacos , Calcinose/tratamento farmacológico , Calcinose/diagnóstico por imagem , Calcinose/patologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/tratamento farmacológico , Doenças das Valvas Cardíacas/tratamento farmacológico , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/patologia , Adulto , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Dilatação Patológica/tratamento farmacológico , Seguimentos , Método Duplo-Cego , Resultado do Tratamento , Aorta/diagnóstico por imagem , Aorta/patologia , Aorta/efeitos dos fármacos , Valvopatia Aórtica/tratamento farmacológico , Estenose da Valva AórticaRESUMO
Background: Chronic aortic regurgitation (AR) is a common valvular disease characterized by an overload of left ventricular volume and pressure. Accurate assessment of the heart from all angles is crucial for effective clinical management and prognostic evaluation of AR patients. As an advanced imaging technique, cardiac magnetic resonance (CMR) has become the gold standard for assessing cardiac volume and function. Accordingly, this study aimed to evaluate the prognostic value of CMR in chronic AR. Methods: EMBASE, Cochrane Library, PubMed, and Web of Science were searched for clinical studies published between inception and July 19, 2022. Only studies that used CMR to assess patients with chronic isolated AR and provided prognostic data were included. Results: For our analysis, 11 studies, which involved 1702 subjects and follow-up periods of 0.6-9.7 years, were eligible. We identified 13 CMR-related parameters associated with AR prognosis. With aortic valve surgery as the outcome, we estimated the pooled hazard ratios (HRs) for four of these parameters: aortic regurgitation fraction (ARF), aortic regurgitation volume (ARV), left ventricle end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV). The pooled HR for ARF was found to be 4.31 (95% confidence interval [CI]: 1.12-16.59, p = 0.034), while that for ARV was 3.88 (95% CI: 0.71-21.04, p = 0.116). Additionally, the combined HRs of LVEDV and LVESV were estimated to be 2.20 (95% CI: 1.04-4.67, p = 0.039) and 3.14 (95% CI: 1.22-8.07, p = 0.018), respectively. Conclusions: The assessment of ARF, LVEDV, and LVESV via CMR has significant prognostic value in predicting the prognosis of AR patients with aortic valve surgery as an endpoint. It is recommended to consider using multi-parameter CMR in the clinical management of AR patients for timely interventions and effective prognostic evaluation.
RESUMO
An aortic valve with a coronary cusp adherent to the aortic wall is a rare anomaly. Furthermore, an adherent coronary cusp with fenestration is even rarer. Here, we report a case of aortic valve regurgitation with an adherent and fenestrated left coronary cusp. A 45-year-old man with complaints of dyspnea on exertion was hospitalized. Clinical examination revealed severe aortic valve regurgitation associated with poor cardiac function. He had a history of cardiac murmur present since childhood; however, the details of his cardiac history are unknown. During surgery, a fenestrated left coronary cusp adherent to the aortic wall was observed. Following resection of all aortic cusps, we performed an aortic valve replacement with a mechanical valve. The postoperative recovery was uneventful. In this case, the left coronary artery was perfused by a small fenestration in the adherent coronary cusp. In such cases, the adherent coronary cusp should be released to alleviate the possibility of sudden death and ischemic myocarditis.
Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Aorta/diagnóstico por imagem , Aorta/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Criança , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.
Assuntos
Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Taxa de SobrevidaRESUMO
OBJECTIVES: This study attempted to evaluate the characteristics and prognostic value of myocardial fibrosis (MF) in aortic insufficiency (AI) patients with bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) by cardiac magnetic resonance (CMR). METHODS: A total of 314 adults with CMR-diagnosed AI were retrospectively retrieved. Of them, 166 patients with moderate or severe AI were included and divided into two groups: BAV group (N = 46) and a TAV group (N = 120). The presence and characteristics of MF were assessed with CMR. The patients were followed for adverse clinical events. The prognostic capability of the parameters was assessed using Cox regression model. RESULTS: LV fibrosis was more common in the BAV group than in the TAV group (65.2% vs. 45.0%; p = 0.020). There was a strong association between BAV and MF even after adjusting for clinical and imaging variables (odds ratio: 3.57; p = 0.031). Kaplan-Meier analysis showed a higher rate of clinical adverse events in AI+BAV patients with MF during a median follow-up of 4.7 years. Multivariate Cox regression analysis showed that late gadolinium enhancement (LGE) was an independent predictor of clinical adverse outcome. CONCLUSION: MF is more common in AI with BAV than with TAV and is a predictor of clinical adverse events. KEY POINTS: ⢠The presence and extent of late gadolinium enhancement of left ventricular were more common and severer in the bicuspid aortic valve group than in the tricuspid aortic valve group in aortic insufficiency patients. ⢠Bicuspid aortic valve was an independent factor for myocardial fibrosis in aortic insufficiency patients. ⢠Late gadolinium enhancement could be used as an independent predictor of adverse clinical events in this population.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Adulto , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico por imagem , Meios de Contraste , Fibrose , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética , Prognóstico , Estudos RetrospectivosRESUMO
OBJECTIVE: Speckle-tracking echocardiography (STE) deformation parameters detect latent LV dysfunction in chronic aortic regurgitation (AR) and are associated with outcomes. The aim of the study was to evaluate cardiac magnetic resonance (CMR) feature tracking (FT) deformation parameters in asymptomatic patients with AR and implications in outcomes. METHODS: Fifty-five patients with AR and 54 controls were included. Conventional functional CMR parameters, aortic regurgitant volume, and fraction were assessed. CMR-FT analysis was performed with a dedicated software. Clinical data was obtained from hospital records. A combined endpoint included all-cause mortality, cardiovascular mortality, aortic valve surgery, or cardiovascular hospital admission due to heart failure. RESULTS: Left ventricular (LV) mechanics is impaired in patients with significant AR. Significant differences were noted in global longitudinal strain (GLS) between controls and AR patients (- 19.1 ± 2.9% vs - 16.5 ± 3.2%, p < 0.001) and among AR severity groups (- 18.3 ± 3.1% vs - 16.2 ± 1.6% vs - 15 ± 3.5%; p = 0.02 for AR grades I-II, III, and IV). In univariate and multivariate analyses, circumferential strain (GCS) and global radial strain (GRS) but not GLS were associated with and increased risk of the end point with a HR of 1.26 (p = 0.016, 1.04-1.52) per 1% worsening for GCS and 0.90 (p = 0.012, 0.83-0.98) per 1% worsening for GRS. CONCLUSIONS: CMR-FT myocardial deformation parameters are impaired in patients with AR not meeting surgical criteria. GLS decreases early in the course of the disease and is a marker of AR severity while GCS and GRS worsen later but predict a bad prognosis, mainly the need of aortic valve surgery. KEY POINTS: ⢠CMR feature tracking LV mechanic parameters may be reduced in significant chronic AR with normal EF. ⢠LV mechanics, mainly global longitudinal strain, worsens as AR severity increases. ⢠LV mechanics, specially global radial and circumferential strain, is associated with a worse prognosis in AR patients.
Assuntos
Insuficiência da Valva Aórtica , Disfunção Ventricular Esquerda , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Prognóstico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular EsquerdaRESUMO
OBJECTIVE: To evaluate the evidence for common therapeutic controversies in the medical management of valvular heart disease (VHD). DATA SOURCES: A literature search of PubMed (inception to December 2020) was performed using the terms angiotensin-converting enzyme (ACE) inhibitors or angiotensin receptor blockers (ARBs) and aortic stenosis (AS); and adrenergic ß-antagonists and aortic valve regurgitation (AR) or mitral stenosis (MS). STUDY SELECTION AND DATA EXTRACTION: Randomized controlled trials (RCTs) and meta-analyses conducted in humans and published in English that reported ≥1 clinical outcome were included. DATA SYNTHESIS: Nine articles were included: 3 RCTs and 1 meta-analysis for ACE inhibitors/ARBs in AS, 1 RCT for ß-blockers in AR, and 4 RCTs for ß-blockers in MS. Evidence suggests that ACE inhibitors/ARBs do not increase the risk of adverse outcomes in patients with AS but may delay valve replacement. ß-Blockers do not appear to worsen outcomes in patients with chronic AR and may improve left-ventricular function in patients with a reduced ejection fraction. ß-Blockers do not improve and may actually worsen exercise tolerance in patients with MS in sinus rhythm. RELEVANCE TO PATIENT CARE AND CLINICAL PRACTICE: ACE inhibitors/ARBs and ß-blockers can likely be safely used in patients with AS or AR, respectively, who have a compelling indication. There is insufficient evidence to recommend routine use of ß-blockers in patients with MS without atrial fibrillation. CONCLUSIONS: Common beliefs about the medical treatment of VHD are not supported by high-quality data. There remains a need for larger-scale RCTs in the medical management of VHD.
Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Antagonistas Adrenérgicos beta/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Doenças das Valvas Cardíacas/tratamento farmacológico , HumanosRESUMO
Aortic insufficiency (AI) is an important adverse event in patients with continuous-flow (CF) left ventricular assist device (LVAD) support. AI is often progressive, resulting in elevated 2-year morbidity and mortality. The effectiveness of echocardiographic ramp studies in patients with AI has been unclear. Here, we describe a patient with a CF-LVAD implant who underwent aortic valve replacement (AVR), following assessment of AI using a hemodynamic ramp test with simultaneous echocardiography and right heart catheterization (RHC). The patient was a 21-year-old man with cardiogenic shock due to acute myocarditis, who underwent HeartWare CF-LVAD (HVAD) implantation. Heart failure persisted despite increased doses of diuretics and inotrope, as well as an increased HVAD pump rate. HVAD monitoring revealed a correlation between increased HVAD pump rate and flow at each speed step. A hemodynamic ramp test with simultaneous transthoracic echocardiography and RHC revealed a significant discrepancy between HVAD pump flow and cardiac output (CO) at each speed step; moreover, pulmonary capillary wedge pressure remained high. Therefore, the patient underwent AVR. Subsequently, his low CO symptoms disappeared and inotropes were successfully discontinued. A postoperative hemodynamic ramp test revealed that AVR had successfully closed the loop of blood flow and reduced the discrepancy between HVAD pump flow and CO, thereby increasing CO. The patient was then discharged uneventfully. In conclusion, a hemodynamic ramp test with simultaneous echocardiography and RHC was useful for the evaluation of the causal relationship between AI and low CO, and for selection of surgical treatment for AI in a patient with CF-LVAD.
Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Testes de Função Cardíaca/métodos , Coração Auxiliar , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Débito Cardíaco/fisiologia , Hemodinâmica/fisiologia , Humanos , Masculino , Função Ventricular Esquerda/fisiologia , Adulto JovemRESUMO
BACKGROUND AND AIM OF THE STUDY: HAART 300 is an internal geometric annuloplasty ring. The safety and efficacy of this novel device in aortic valve (AV) repair in a single referral center are reported. METHODS: Twenty patients with trileaflet AV insufficiency with ascending aorta and/or aortic root enlargement were included. Subannular implantation was performed to correct annular dilatation, whereas concomitant leaflet repair was performed whenever required. All but two patients also received ascending aorta replacement, whereas selective sinus replacement was performed in all but five patients. RESULTS: Follow-up was for a maximum of 3.8 years and a mean of 2.2 years. Mean age was 54.2 years old. Moderate to severe preoperative AV insufficiency was noted in 75% of patients, whereas 70% of them had an ascending aorta over 45 mm. One patient was lost from follow-up. Overall mortality as well as major complication rates were zero. Early postoperatively, no more than mild AV regurgitation was detected, whereas only one patient appeared with moderate AV regurgitation during our 2.2-year follow-up. New York Heart Association class was also significantly lower compared to preoperative values and valve gradients remained low at last follow-up. CONCLUSIONS: Geometric ring annuloplasty is a safe and effective valve sparing approach to deal with AV insufficiency contributing to overall root reconstruction. Short-term results are excellent rendering this easily reproducible and versatile method very attractive.
Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Terapia Antirretroviral de Alta Atividade , Aorta , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Humanos , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Humanos , Masculino , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
PURPOSE OF REVIEW: Concomitant valve disease is common in patients undergoing continuous-flow left ventricular assist device (CF-LVAD) implantation. In this review, we characterize the epidemiology and management of aortic valve disease following CF-LVAD. RECENT FINDINGS: Studies suggest that 20-40% of patients have mild or greater aortic insufficiency (AI) at baseline and that AI progresses following CF-LVAD implantation. AI, either pre-existing or de novo, can have deleterious effects on LVAD efficacy and clinical outcomes. Surgical methods to correct AI in patients supported with CF-LVAD include central oversewing of the aortic valve, complete closure of the aortic valve, patch closure of the ventriculo-aortic junction, or aortic valve replacement with a bioprosthesis. Transcatheter options have recently emerged as feasible modalities to address AI. CF-LVADs contribute to the progression of aortic insufficiency (AI) and its development de novo. Prompt recognition, assessment, and treatment are important. Aortic valve repairs and replacements, now including TAVR, are the primary surgical methods to correct AI.
Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/fisiopatologia , Progressão da Doença , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Função Ventricular Esquerda/fisiologiaRESUMO
A series of hemodynamic and pathological responses occur in chronic aortic regurgitation, which eventually result in myocardial fibrosis and irreversible left ventricular dysfunction. According to guidelines, valvular surgery is recommended with the development of symptoms, left ventricular systolic dysfunction, or left ventricular dilatation. The optimal timing of surgical intervention has recently been questioned with documentation of irreversible myocardial damage resulting in incomplete left ventricular recovery and adverse clinical outcomes after surgery. Recognizing the shortcomings of the guidelines, we performed a comprehensive review on the novel diagnostic methods that have been shown to improve the detection of subclinical ventricular dysfunction in chronic aortic regurgitation and to improve prediction of outcomes.
Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/terapia , Doenças Assintomáticas , Fármacos Cardiovasculares/uso terapêutico , Doença Crônica , Progressão da Doença , Diagnóstico Precoce , Feminino , Fibrose , Implante de Prótese de Valva Cardíaca , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Hipertrofia Ventricular Esquerda/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacosRESUMO
BACKGROUND: Synergistic interactions between neprilysin inhibition (NEPi) with sacubitril and angiotensin receptor type1 blockade (ARB) with valsartan have been implicated in improvement of left ventricular (LV) contractility, relaxation, exercise tolerance, and fibrosis in preexisting heart failure (HF) induced by aortic valve insufficiency (AVI). It is not known whether this pharmacologic synergy can prevent cardiovascular pathology in a similar AVI model. Our aim was to investigate the pharmacology of sacubitril/valsartan in an experimental setting with therapy beginning immediately after creation of AVI. METHODS: HF was induced through partial disruption of the aortic valve in rats. Therapy began 3 hours after valve disruption and lasted 8 weeks. Sacubitril/valsartan (68 mg/kg), valsartan (31 mg/kg), sacubitril (31 mg/kg), or vehicle were administered daily via oral gavage (N=8 in each group). Hemodynamic assessments were conducted using Millar technology, and an exercise tolerance test was conducted using a rodent treadmill. RESULTS: Only sacubitril/valsartan increased total arterial compliance and ejection fraction (EF). Therapies with sacubitril/valsartan and valsartan similarly improved load-dependent (dP/dtmax) and load independent indices (Ees) of LV contractility, and exercise tolerance, whereas sacubitril did not. None of the therapies improved LV relaxation (dP/dtmin), whereas all reduced myocardial fibrosis. CONCLUSIONS: 1) The synergistic interaction between NEPi and ARB in early therapy with sacubitril/valsartan leads to increased total arterial compliance and EF. 2) Improvement in indices of LV contractility, and exercise tolerance with sacubitril/valsartan is likely because of ARB effect of valsartan. 3) All three therapies provided antifibrotic effects, suggesting both ARB and NEPi are capable of reducing myocardial fibrosis.
Assuntos
Aminobutiratos/administração & dosagem , Antagonistas de Receptores de Angiotensina/administração & dosagem , Insuficiência da Valva Aórtica/tratamento farmacológico , Insuficiência Cardíaca/tratamento farmacológico , Tetrazóis/administração & dosagem , Valsartana/administração & dosagem , Aminobutiratos/metabolismo , Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Bloqueadores do Receptor Tipo 1 de Angiotensina II/metabolismo , Antagonistas de Receptores de Angiotensina/metabolismo , Animais , Insuficiência da Valva Aórtica/metabolismo , Compostos de Bifenilo , Combinação de Medicamentos , Interações Medicamentosas/fisiologia , Sinergismo Farmacológico , Tolerância ao Exercício/efeitos dos fármacos , Tolerância ao Exercício/fisiologia , Insuficiência Cardíaca/metabolismo , Masculino , Ratos , Ratos Sprague-Dawley , Volume Sistólico/efeitos dos fármacos , Volume Sistólico/fisiologia , Tetrazóis/metabolismo , Valsartana/metabolismoRESUMO
OBJECTIVE: The objective of this study was to analyze the available literature on using transcatheter aortic valve replacement (TAVR) for native aortic regurgitation (AR). BACKGROUND: Surgical aortic valve replacement is the gold standard therapy for native AR. TAVR has emerged as an alternative approach in high-risk patients. METHODS: MEDLINE, Scopus, and Cochrane CENTRAL were searched for reports of at least 5 patients undergoing TAVR for native AR. Outcomes included 30-day mortality, myocardial infarction, stroke, major bleeding, postprocedural moderate to severe AR, and device success. Pooled estimates were calculated using a random-effects model. Subgroup analysis and a meta-regression were performed to study the effects of study level covariates on outcomes. RESULTS: Nineteen studies (n =998 patients) were included. The rate of procedural success per Valve Academic Research Consortium - 2 (VARC-2) criteria was 86.2% (78.8%-92.2%]. Thirty-day mortality was 11.9% (9.4%-14.7%). Subgroup analysis showed the use of new generation valves was associated with lower 30-day mortality (P = 0.02) and higher device success (P = 0.009) compared with early generation valves. There was no significant difference (P = 0.13) in the rate of 30-day mortality between patients receiving purpose-specific [8.2% (4.3%-13.1%); I2 = 0%] and nonpurpose specific valves [13.0% (8.2%-18.6%); I2 = 25%]. However, device success was higher (P = 0.02) in patients who received purpose-specific valves [96.3% (92.2%-98.9%); I2 = 0%] compared with nonpurpose specific valves [84.4% (75%-91.9%); I2 =46%]. CONCLUSION: TAVR for native AR is associated with acceptable procedural success but increased early mortality. However, the safety and the efficacy of the procedure increased with newer valves.
Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
Objective: To investigate the cardiovascular magnetic resonance (CMR) imaging characteristics and influence factors of aortic insufficiency (AI) patients with myocardial fibrosis. Method: This retrospective study included 59 AI patients who received CMR and transthoracic echocardiography (TTE) examinations from June 2011 to February 2015. AI patients were divided into 2 groups: bicuspid aortic valve (BAV) group (n=30) and non-BAV group (n=29). Patients were also divided into late gadolinium enhancement (LGE) group (n=27) and non-LGE group (n=32). The baseline clinical characteristics were collected through electronic medical records. Hemodynamic parameters such as grade of AI, cardiac functional parameters and LGE mass fraction (LGE%) were measured by CMR post-processing analysis. Kappa test was used to assess the consistency of AI severity between CMR and TTE, and the multivariate logistic regression analysis was performed to evaluate influence factors of myocardial fibrosis in AI patients. Results: (1) 56 (94.9%) patients were male, and the mean age was (44.2±11.0) years old. There was no significant difference in age and gender, hypertension, hyperlipidemia, alcoholic consumption between BAV and non-BAV group (all P>0.05). There were a higher proportion of smoking history (P=0.008), a lower body mass index (BMI) (P=0.020) in the LGE group than in the non-LGE group. (2) The accuracy of CMR in diagnosis of BAV was 96.7% (29/30) compared to the gold standard. In the BAV group, 20 patients (66.7%) were with fusion of left and right cusp (L-R), 5 patients (16.7%) were with fusion of right and noncoronary cusp (R-N), 5 patients (16.7%) were with fusion of left and noncoronary cusp (L-N); patients with BAV had larger left ventricular end diastolic volume index (LVEDVi), left ventricular end systolic volume index (LVESVi), higher proportion of LGE and lower left ventricular ejection fraction (LVEF) than those in non-BAV group (all P<0.05). There were 19 patients with BAV in the LGE group, the cases of L-R, R-N, L-N were 10 (52.6%), 5 (26.3%), and 4 (21.1%), respectively. In the non-LGE group, patients with BAV of L-R, R-N, L-N were 10 (90.9%), 0, and 1 (9.1%), respectively. Patients with LGE had lower body surface area (BSA), LVEF and larger LVEDVi, LVESVi, left ventricular mass index (LVMi) and higher proportion of BAV compared patients without LGE. In addition, the proportion of moderate and severe AI patients was significantly higher in BAV group than in non-BAV group (P=0.009). (3) The consistency of CMR and TTE in evaluating the severity of AI patients: the agreement between TTE and CMR regarding AI severity was satisfactory (kappa value was 0.624, 95%CI 0.402-0.831, P<0.001). (4) The linear regression analysis demonstrated a negative correlation between LVEF and LGE% in BAV and non-BAV group (P<0.001). The multivariate logistic regression analysis showed that the presence of BAV was an independent risk factor of left ventricucar fibrosis (OR=5.050, 95%CI 1.220-20.908, P=0.025) after adjustment for LVEF, hypertension, LVEDVi and LVMi. Conclusion: Multi-parametric CMR provides a satisfactory noninvasive tool for estimation of myocardial fibrosis and ventricular remodeling in patients with AI, and BAV is an independent risk factor for myocardial fibrosis in patients with AI.
Assuntos
Miocárdio , Adulto , Meios de Contraste , Feminino , Fibrose , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Função Ventricular EsquerdaRESUMO
OBJECTIVE: To compare the safety and efficacy of transcathether aortic valve-in-valve implantation (ViV-TAVI) in degenerated stentless bioprostheses with failed stented valves and degenerated native aortic valves. INTRODUCTION: Little is known about ViV-TAVI in degenerated stentless valves. METHODS: Out of 45 ViV-TAVI procedures reported in the POL-TAVI registry, 20 failed stentless valves were compared with 25 stented prostheses and propensity-matched with 45 native TAVI cases. The mean follow-up was 633 (95% confidence interval [CI], 471-795) days and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. RESULTS: Patients with degenerated stentless valves were younger (65.6, CI 58-73.1 years vs 75.6, CI 72.2-78 [stented] vs 80.1, CI 78.7-81.6 y. [native], P < 0.001). Implantation was required later after surgery (11.5, CI 8-14.9 years) in the stentless cohort as compared with the stented one (6.2, CI 4.7-7.6 years, P = 0.006). ViV-TAVI in the stentless group was also associated with larger amount of contrast (211, CI 157-266 mL vs 135, CI 104-167 mL [stented] vs 132 (119-145) mL [native], P = 0.022). Using VARC-2 composite endpoints, ViV-TAVI in stentless prostheses was characterized by a lower device success (50% vs 76% in stented vs 88.9% in native TAVI, P < 0.001), but comparable early safety up to 30 days (73.7% vs 84% vs 81.8%, respectively, log-rank P = 0.667) and long-term clinical efficacy beyond 30 days (72.2% vs 72% vs 73.8%, respectively, log-rank P = 0.963). CONCLUSIONS: Despite technical challenges and a lower device success, ViV-TAVI in stentless aortic bioprostheses achieves similar safety, efficacy, and functional improvement as in stented or degenerated native valves.
Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Sistema de Registros , Stents , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
The aim of this study was to outline the clinical features of syphilitic aortic aneurysm. The study materials were based on a comprehensive literature review of publications on syphilitic aortic aneurysm published between 2000 and 2017. Syphilitic aortic aneurysm occurred most commonly in the ascending aorta in either a saccular or a fusiform shape. Syphilitic aortic aneurysm was often complicated by aortic valve insufficiency (in almost half of the patients), and by a coronary artery/ostium lesion in 16.5% of the patients. Aortic valve operation was necessary in one fourth, and coronary artery surgery accounted for less than one fifth of patients warranting a surgical treatment. Although there was no difference in the survival rates between the surgically and conservatively treated patients, an aggressive treatment should be performed when diagnosis is made due to the potential risks of aneurysm rupture and sudden death.
Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Insuficiência da Valva Aórtica , Sífilis Cardiovascular , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Humanos , Sífilis Cardiovascular/diagnóstico , Sífilis Cardiovascular/cirurgia , Tomografia Computadorizada por Raios XRESUMO
Objective: To report on the two years outcome of Chinese multi-center study of the treatment of high risk non-calcified pure aortic regurgitation with transcatheter heart valve replacement (TAVR) using domestic made J-Valve™ system. Methods: The national multi-center clinical study of the treatment of high risk non-calcified pure aortic regurgitation with transcatheter heart valve replacement using domestic made J-Valve™ system was conducted during the period from April 2014 to July 2015. The follow-up time was up to 2 years. Forty-three cases with predominant aortic valve regurgitation were enrolled for transapical implantation of the J-Valve™ system from 3 Chinese centers, including 16 patients from Zhongshan Hospital, Fudan University, 23 patients from West China Hospital, Sichuan University, and 4 patients from Fuwai Cardiovascular Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College. There were 30 males and 13 females in this cohort. The age of the patients was (74±6) years (range: 61 to 84 years). The patiens were all sympotmatic preoperatively. All patients were considered at prohibitive or high risk for surgical valve replacement (Logistic European System for Cardiac Operative Risk Evaluation of (25.5±5.3)%, range: 20.0% to 44.4%) after evaluation by an interdisciplinary heart team. Comprehensive clinical and echocardiographic assessments were scheduled before discharge and at 30 days, 12 months, and 24 months after the procedure. Results: One patients was converted to surgical aortic valve replacement (SAVR) due to valve embolism into the arch. The other 42 cases had J-Valve™ systems implanted successfully. One patient died from multi-organ disorder due to paravalvular leak (PVL) during perioperative period. There was no acute myocardial infarction, stroke or coronary obstruction during the perioperative period. The median follow-up time was 725 days (range: 6 to 1 082 days). There were 5 patients died during the 2 years, follow-up, 2 patients had stroke, 2 patients had permanent pacemaker implanted. Three patients had valve related reinterventions: One for intraoperative valve embolism into the aortic arch followed by a conversion to SAVR which was mentioned above. One patient underwent SAVR on the postoperative day 6 due to moderate PVL and ventricular dysfunction. One patient underwent SAVR 6 months after primary procedure due to prosthesis thrombosis and severe aortic valve stenosis.Thirty-six patients with J-valve™ implanted survived to the latest echocardiogram follow-up, 25 patients had trivial or less PVL, 9 patients had mild PVL, and the transvalvular gradient after valve implantation was favorable at (9.8±5.8) mmHg (1 mmHg=0.133 kPa). Conclusions: Transapical implantation of domestic made J-Valve™ transcatheter heart valve system for patients with predominant aortic regurgitation has a excellent early outcome. This novel technology is safe and effective.
Assuntos
Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica , China , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco , Resultado do TratamentoRESUMO
BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital cardiac defect. This study sought to determine QAV frequency in a large echocardiography database, to characterize associated cardiovascular abnormalities, and to describe long-term outcomes. METHODS AND RESULTS: Fifty patients (mean ± SD age, 43.5 ± 21.8 years at the time of the index diagnosis; female sex, 52%) received a diagnosis of QAV between January 1, 1975, and March 14, 2014 (frequency, 0.006%). The QAV was type A in 32% and type B in 32% (Hurwitz and Roberts classification). Aortic dilatation was present in 29% of the patients, and 26% had moderate or severe aortic valve regurgitation at the index diagnosis. Stenosis affected only 8% of the valves and was mild. Other findings, including abnormalities of other cardiac valves, septal defects, persistent left superior vena cava, and patent ductus arteriosus, were present in 32% of patients. During a mean ± SD follow-up of 4.8 ± 5.6 years, 8 patients underwent aortic valve surgery, with severe aortic valve regurgitation being the surgical indication in 7 patients. One patient with mild to moderate aortic valve regurgitation underwent aortic valve repair for obstruction of the left coronary ostium by the accessory cusp of QAV. No infective endocarditis or aortic dissection was found. Overall survival was 91.5% and 87.7% at 5 and 10 years. CONCLUSIONS: Aortic dilatation and other structural cardiac abnormalities were relatively common among patients with QAV. Aortic valve regurgitation was the predominant hemodynamic abnormality and the indication for aortic valve surgery in most patients who received surgery. Long-term survival was excellent.
Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Anormalidades Cardiovasculares/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia , Adulto JovemRESUMO
Besides providing spatial anatomic information on heart valves, real-time three-dimensional echocardiography (3DE) combined with color Doppler has the potential to overcome the limitations of flow quantification inherent to conventional 2D color Doppler methods. Recent studies validated the application of color Doppler 3DE (cD-3DE) for the quantification of regurgitation flow based on the vena contracta area (VCA) and the proximal isovelocity surface area (PISA) methods. Particularly the assessment of VCA by cD-3DE led to a change of paradigm by understanding of the VCA as being strongly asymmetric in the majority of patients and etiologies. This review provides a comprehensive description of the different concepts of cD-3DE-based flow quantification in the setting of different valvular heart diseases and their presentation in recent guidelines.