Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Brain Inj ; 38(6): 417-424, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38406989

RESUMO

OBJECTIVE: To determine whether cognitive learning potential measured with the dynamic Wisconsin Card Sorting Test has added value in predicting rehabilitation outcome in elderly patients post-stroke after controlling for age, ADL independence at admission, global cognitive functioning and depressive symptoms. METHODS: Participants were patients with stroke admitted to a geriatric rehabilitation unit. ADL independence (Barthel Index) at discharge was used as measure for rehabilitation outcome. Predictor variables included age, ADL independence at admission, global cognitive functioning (Montreal Cognitive Assessment), depressive symptoms (Geriatric Depression Scale) and cognitive learning potential measured with the dWCST. RESULTS: Thirty participants were included. Bivariate analyses showed that rehabilitation outcome was significantly correlated with ADL independence at admission (r = 0.443, p = 0.014) and global cognitive functioning (r = 0.491, p = 0.006). Regression analyses showed that the dWCST was not an independent predictor of rehabilitation outcome. ADL independence at admission was the only significant predictor of rehabilitation outcome (beta = 0.480, p = 0.007). CONCLUSIONS: Cognitive learning potential, measured with the dWCST has no added value in predicting rehabilitation outcome in elderly patients post-stroke. ADL independence at admission was the only significant predictor of rehabilitation outcome. REGISTRATION NUMBER NETHERLANDS TRIAL REGISTER: Trial NL7947.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Idoso , Atividades Cotidianas , Teste de Classificação de Cartas de Wisconsin , Acidente Vascular Cerebral/complicações , Resultado do Tratamento , Cognição
2.
Sensors (Basel) ; 23(2)2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36679591

RESUMO

Structural Health Monitoring (SHM) systems allow three types of diagnostic tasks to be performed, namely damage identification, loads monitoring, and damage prognosis. Only if all three tasks are correctly fulfilled can the useful remaining life of a structure be estimated credibly. This paper deals with the second task and aimed to extend state-of-the-art in load identification, by demonstrating that it is feasible to achieve it through the analysis of response signals captured with high-speed three-dimensional Digital Image Correlation (HS 3D-DIC). The efficacy of the proposed procedure is demonstrated experimentally on a frame structure under broadband vibration excitation. Full-field vibration displacement signals are captured with the use of two high-speed cameras and processed with 3D-DIC. Loads are identified with two different algorithms based on inverting the Frequency Response Function (FRF) matrix and modal filtration (MF). The paper discusses both methods providing their theoretical background and experimental performance.


Assuntos
Algoritmos , Imageamento Tridimensional , Imageamento Tridimensional/métodos , Vibração , Eletrocardiografia
3.
Sensors (Basel) ; 23(1)2022 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-36616769

RESUMO

This article describes the validation of a 3D dynamic interaction model of the train-track-bridge system on a bowstring-arch railway bridge based on experimental tests. The train, track, and bridge subsystems were modeled on the basis of large-scale and highly complex finite elements models previously calibrated on the basis of experimental modal parameters. The train-bridge dynamic interaction problem, in the vertical direction, was efficiently solved using a dedicated computational application (TBI software). This software resorts to an uncoupled methodology that considers the two subsystems, bridge and train, as two independent structures and uses an iterative procedure to guarantee the compatibility of the forces and displacements at the contact points at each timestep. The bridge subsystem is solved by the mode superposition method, while the train subsystem is solved by a direct integration method. The track irregularities were included in the dynamic problem based on real measurements performed by a track inspection vehicle. A dynamic test under traffic actions allowed measuring the responses in the bridge, track, and vehicles, which were synchronized by GPS systems. The test results demonstrated the occurrence of upward displacements on the deck, which is a characteristic of structures with an arch structural behavior, as well as an alternation of tensile/compressive stresses between the rail and deck due to the deck-track composite effect. Furthermore, the acceleration response of the bridge proved to be significantly influenced by the train operating speed. The validation procedure involved comparing the dynamic responses obtained from the train-bridge interaction model, including track irregularities, and the responses obtained experimentally, through the test under traffic actions. A very good correlation was obtained between numerical and experimental results in terms of accelerations, displacements, and strains. The contributions derived from the parametric excitation of the train, the global/local dynamic behavior of the bridge, and the excitation derived from the track irregularities were decisive to accurately reproduce the complex behavior of the train-track-bridge system.


Assuntos
Aceleração , Compressão de Dados , Software
4.
J Exp Child Psychol ; 153: 83-109, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27721033

RESUMO

The current study investigated developmental trajectories of analogical reasoning performance of 104 7- and 8-year-old children. We employed a microgenetic research method and multilevel analysis to examine the influence of several background variables and experimental treatment on the children's developmental trajectories. Our participants were divided into two treatment groups: repeated practice alone and repeated practice with training. Each child received an initial working memory assessment and was subsequently asked to solve figural analogies on each of several sessions. We examined children's analogical problem-solving behavior and their subsequent verbal accounts of their employed solving processes. We also investigated the influence of verbal and visual-spatial working memory capacity and initial variability in strategy use on analogical reasoning development. Results indicated that children in both treatment groups improved but that gains were greater for those who had received training. Training also reduced the influence of children's initial variability in the use of analogical strategies with the degree of improvement in reasoning largely unrelated to working memory capacity. Findings from this study demonstrate the value of a microgenetic research method and the use of multilevel analysis to examine inter- and intra-individual change in problem-solving processes.


Assuntos
Desenvolvimento Infantil , Memória de Curto Prazo , Resolução de Problemas , Criança , Feminino , Humanos , Aprendizagem , Masculino , Pensamento
5.
Nano Lett ; 16(1): 255-63, 2016 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-26540253

RESUMO

The characterization of nanomaterials under high strain rates is critical to understand their suitability for dynamic applications such as nanoresonators and nanoswitches. It is also of great theoretical importance to explore nanomechanics with dynamic and rate effects. Here, we report in situ scanning electron microscope (SEM) tensile testing of bicrystalline silver nanowires at strain rates up to 2/s, which is 2 orders of magnitude higher than previously reported in the literature. The experiments are enabled by a microelectromechanical system (MEMS) with fast response time. It was identified that the nanowire plastic deformation has a small activation volume (<10b(3)), suggesting dislocation nucleation as the rate controlling mechanism. Also, a remarkable brittle-to-ductile failure mode transition was observed at a threshold strain rate of 0.2/s. Transmission electron microscopy (TEM) revealed that along the nanowire, dislocation density and spatial distribution of plastic regions increase with increasing strain rate. Furthermore, molecular dynamic (MD) simulations show that deformation mechanisms such as grain boundary migration and dislocation interactions are responsible for such ductility. Finally, the MD and experimental results were interpreted using dislocation nucleation theory. The predicted yield stress values are in agreement with the experimental results for strain rates above 0.2/s when ductility is pronounced. At low strain rates, random imperfections on the nanowire surface trigger localized plasticity, leading to a brittle-like failure.

6.
J Prosthodont ; 23(5): 353-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24417233

RESUMO

PURPOSE: The goals of part 2 of the study presented here were 1) to assess whether there is a difference in failure mode of different thicknesses (2.0, 1.5, 1.0, and 0.5 mm) of anatomically standardized full contour monolithic lithium disilicate restorations for posterior teeth, and 2) to assess if there is a difference among various crown thicknesses when these restorations are subjected to dynamic load forces common for posterior teeth. MATERIALS AND METHODS: Four groups (n = 10), each with a different thickness of anatomically appropriate all-ceramic crowns, were to be tested as established from the statistical analysis of the preliminary phase. Group 1: 2.0 mm; group 2: 1.5 mm; group 3: 1.0 mm; group 4: 0.5 mm. The specimens were adhesively luted to the corresponding die, and underwent dynamic cyclic loading (380 to 390 N) completely submerged in an aqueous environment until a failure was noted by graphic recording and continuous monitoring. RESULTS: There was a statistically significant difference of the fatigue cycles to failure among four groups (p < 0.001; Kruskal-Wallis test). The mean number of cycles to fail for 2.0 mm specimens was 17 times more than the mean number of cycles to fail for 1.0 mm specimens and 1.5 times more than the mean number of cycles to fail for 1.5 mm specimens. The 0.5 mm specimens failed with one cycle of loading. A qualitative characteristic noted among the 2.0 mm specimens was wear of the area of indenter contact followed by shearing of the material and/or crack propagation. CONCLUSION: Based on the findings of this study, it may be reasonable to consider a crown thickness of 1.5 mm or greater for clinical applications of milled monolithic lithium disilicate crowns for posterior single teeth.


Assuntos
Coroas , Porcelana Dentária/química , Falha de Restauração Dentária , Condicionamento Ácido do Dente/métodos , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Ácido Fluorídrico/química , Teste de Materiais , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Preparo Prostodôntico do Dente/métodos , Água/química
7.
Materials (Basel) ; 17(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38399077

RESUMO

Reciprocating motion expands the lifetime of endodontic instruments during the preparation of severely curved root canals. This study aimed to investigate the time to fracture (TTF) and number of cycles to failure (NCF) of different reciprocating instruments (n = 20 in each group) at body temperature using a dynamic testing model (amplitude = 3 mm). Reciproc Blue (RPB), size 25/.08, WaveOne Gold (WOG) 25/.07, Procodile (Proc) 25/.06, R-Motion (RM_06) 25/.06 and R-Motion (RM_04) 30/.04 instruments were tested in their specific reciprocating motion in artificial matching root canals (size of the instrument ± 0.02 mm; angle of curvature 60°, radius 5.0 mm, and centre of curvature 5.0 mm from apical endpoint). The number of fractured instruments, TTF, NCF, the and lengths of the fractured instruments were recorded and statistically analysed using the Chi-Square or Kruskal-Wallis test. Both TTF (median 720, 643, 562, 406, 254 s) and the NCF (3600, 3215, 2810, 2032, 1482 cycles) decreased in the following order RM_06 > RPB > RM_04 > Proc > WOG with partially significant differences. During testing, only six RM_06 instruments fractured, whereas 16/20 (RPB), 18/20 (Proc), and 20/20 (RM_04, WOG) fractures were recorded (p < 0.05). Within the limitations of the present study, blue-coloured RPB and RM instruments exhibited a significantly superior cyclic fatigue resistance compared to SE-NiTi and Gold-wire instruments. Heat treatment, cross-sectional design and core mass significantly influenced the longevity of reciprocating instruments in cyclic dynamic testing.

8.
J Dent ; 144: 104952, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38508442

RESUMO

OBJECTIVES: Evaluation of the two-body wear of lithium-silicate ceramics against different antagonists compared to a direct resin composite and human teeth. METHODS: Initial LiSi Block [LISI], IPS e.max CAD [EMA], and CEREC Tessera [TESE] were investigated and compared with direct resin composite [FILL] and human teeth [tooth]. As antagonists were used: steatite, ceramic, and human enamel. The control group tooth was only tested with enamel antagonist. The combinations underwent thermomechanical aging using a chewing simulator. Material losses were calculated using GOM-analysis software. Kolmogorov-Smirnov test, Kruskal-Wallis H, Mann-Whitney-U-test with Bonferroni correction and Spearman-rho correlation were calculated. A fractographic analysis was performed. RESULTS: Within TESE, enamel antagonists led to lower restoration losses than steatite and ceramic antagonists. Within FILL, enamel and steatite antagonists caused lower material losses compared to ceramic antagonists. Against steatite antagonists, LISI showed lowest material losses. Against ceramic antagonists, the use of LISI led to lower material losses compared to FILL. Against tooth antagonists, TESE showed lower material losses than tooth and FILL and LISI lower than FILL. Within LISI, steatite antagonists showed lower material losses on the antagonist than ceramic. Within EMA, steatite antagonists showed higher material losses than ceramic ones. Within ceramic antagonists, LISI restoration material showed lower material losses than FILL and EMA. CONCLUSIONS: Regardless of the antagonist material, the material losses of LISI and EMA were comparable. However, the abrasion resistance of LISI tended to be higher than EMA. CLINICAL SIGNIFICANCE: LISI is a fully crystallized lithium-silicate ceramic and no longer needs to be processed after milling. In addition, the abrasion resistance is very good, regardless of the antagonist material chosen.


Assuntos
Cerâmica , Resinas Compostas , Esmalte Dentário , Porcelana Dentária , Óxido de Magnésio , Teste de Materiais , Dióxido de Silício , Humanos , Resinas Compostas/química , Porcelana Dentária/química , Esmalte Dentário/efeitos dos fármacos , Cerâmica/química , Materiais Dentários/química , Silicatos/química , Propriedades de Superfície , Desgaste de Restauração Dentária , Desenho Assistido por Computador , Lítio
9.
J Intell ; 12(6)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38921696

RESUMO

A successful adjustment to dynamic changes in one's environment requires contingent adaptive behaviour. Such behaviour is underpinned by cognitive flexibility, which conceptually is part of fluid intelligence. We argue, however, that conventional approaches to measuring fluid intelligence are insufficient in capturing cognitive flexibility. We address the discrepancy between conceptualisation and operationalisation by introducing two newly developed tasks that aim at capturing within-person processes of dealing with novelty. In an exploratory proof-of-concept study, the two flexibility tasks were administered to 307 university students, together with a battery of conventional measures of fluid intelligence. Participants also provided information about their Grade Point Averages obtained in high school and in their first year at university. We tested (1) whether an experimental manipulation of a requirement for cognitive inhibition resulted in systematic differences in difficulty, (2) whether these complexity differences reflect psychometrically differentiable effects, and (3) whether these newly developed flexibility tasks show incremental value in predicting success in the transition from high school to university over conventional operationalisations of fluid intelligence. Our findings support the notion that cognitive flexibility, when conceptualised and operationalised as individual differences in within-person processes of dealing with novelty, more appropriately reflects the dynamics of individuals' behaviour when attempting to cope with changing demands.

10.
Sports Biomech ; : 1-15, 2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36650711

RESUMO

The objective was to determine the reliability and validity of a local positioning system (LPS) promising high accuracy at reduced product costs. Fifty-five random static positions in a gym (54.8 × 26.0 m) were obtained 10 times via LPS (50 Hz) and measuring tape. An athlete's LPS-derived peak and time-series speed and acceleration during dynamic movements (n = 80) were compared with Vicon (100 Hz). Reliability and validity were assessed via Intraclass and Concordance Correlation Coefficients (ICC/CCC), root mean square errors, Bland-Altman plots, and analysis of variance. ICC3,1 (≥0.999) and CCC (0.387-0.999) were calculated for static positions (errors <0.22 m). CCC for time-series speed and acceleration, and peak speed, acceleration, and deceleration were 0.884-0.902, 0.777-0.854, 0.923, 0.486, and 0.731, respectively. Errors were larger in time-series acceleration (14.37 ± 3.77%) than in speed (11.99 ± 5.78%) (ηp2 = 0.472, p < 0.001) and in peak acceleration (28.04 ± 14.34%) and deceleration (25.07 ± 14.90%) than in speed (7.34 ± 6.07%) (ηp2 = 0.091, p < 0.01). LPS achieved excellent reliability and moderate-to-excellent validity of time-series speed and acceleration. The system accurately measured peak speed but not peak acceleration and deceleration. The system is suitable for analyses based on instantaneous speed and acceleration in game sports (e.g., energy estimations).

11.
Appl Neuropsychol Adult ; : 1-11, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36726234

RESUMO

Currently, there is no valid and feasible dynamic test available for assessing learning potential in elderly stroke patients. We designed a dynamic version of the Clock Drawing Task (dCDT) which we compared to the dynamic Wisconsin Card Sorting Test (dWCST). The dWCST has shown adequate validity in adult patients with brain injury but has a long administration time. Participants were 47 stroke patients admitted to a geriatric rehabilitation unit. All participants completed the dCDT, the mean administration time was 7 min. 90.7% of the participants were able to complete the dWCST, the mean administration time was 36 min. The numerical learning potential indices of the dCDT were not significantly correlated. Based on the dCDT, 70.2% of the participants were classified as high achiever, 10.6% as strong learner, 19.2% as poor learner, and none as decliner. The numerical learning potential indices of the dWCST correlated significantly. Based on the dWCST, 5.3% of the participants were classified as high achiever, 42.1% as strong learner, 50% as poor learner, and 2.6% as decliner. The learning potential indices of the dCDT and those of the dWCST were not significantly correlated, indicating poor convergent validity of the dCDT. The results provide no clear support for the use of the dCDT in elderly stroke patients. The dWCST does show adequate validity and feasibility in the elderly stroke population, despite longer administration time. Future research should focus on examining the validity of the dCDT in a larger sample as well as examining the predictive validity of the dWCST.

12.
Biomater Adv ; 152: 213485, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37302211

RESUMO

Ventricular assist devices (VADs) provide an alternative solution to heart transplantation for patients with end-stage heart failure. Insufficient hemocompatibility of VAD components can result in severe adverse events, such as thromboembolic stroke, and readmissions. To enhance VAD hemocompatibility, and avoid thrombus formation, surface modification techniques and endothelialization strategies are employed. In this work, a free form patterning topography is selected to facilitate the endothelialization of the outer surface of the inflow cannula (IC) of a commercial VAD. An endothelialization protocol for convoluted surfaces such as the IC is produced, and the retainment of the endothelial cell (EC) monolayer is evaluated. To allow this evaluation, a dedicated experimental setup is developed to simulate realistic flow phenomena inside an artificial, beating heart phantom with a VAD implanted on its apex. The procedural steps of mounting the system result to the impairment of the EC monolayer, which is further compromised by the developed flow and pressure conditions, as well as by the contact with the moving inner structures of the heart phantom. Importantly, the EC monolayer is better maintained in the lower part of the IC, which is more susceptible to thrombus formation and may therefore aid in minimizing the hemocompatibility related adverse events after the VAD implantation.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Trombose , Humanos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Cânula , Coração Auxiliar/efeitos adversos
13.
Materials (Basel) ; 16(10)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37241516

RESUMO

Due to their good mechanical and other properties, cobalt-chromium alloys (Co-Cr) are often used in prosthetic therapy. The metal structures of prosthetic works can be damaged and break, and depending on the extent of the damage, they can be re-joined. Tungsten inert gas welding (TIG) produces a high-quality weld with a composition very close to that of the base material. Therefore, in this work, six commercially available Co-Cr dental alloys were joined by TIG welding, and their mechanical properties were evaluated to determine the quality of the TIG process as a technology for joining metallic dental materials and the suitability of the Co-Cr alloys used for TIG welding. Microscopic observations were made for this purpose. Microhardness was measured using the Vickers method. The flexural strength was determined on a mechanical testing machine. The dynamic tests were carried out on a universal testing machine. The mechanical properties were determined for welded and non-welded specimens, and the results were statistically evaluated. The results show the correlation between the investigated mechanical properties and the process TIG. Indeed, characteristics of the welds have an effect on the measured properties. Considering all the results obtained, the TIG-welded I-BOND NF and Wisil M alloys showed the cleanest and most uniform weld and, accordingly, satisfactory mechanical properties, highlighting that they withstood the maximum number of cycles under dynamic load.

14.
Traffic Inj Prev ; 23(2): 91-96, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35044289

RESUMO

OBJECTIVE: To compare how errors in child restraint use influence crash injury risk in rearward and forward-facing restraints for a 1-year old occupant. METHODS: Three convertible child restraint systems (CRS) were subjected to frontal dynamic sled tests at 56 km/h in rearward-facing and forward-facing modes in a correct use (baseline) condition and in five incorrect use conditions: loose securing belt, loose harness, partial harness use, top tether slack, and three minor errors. Excursion, head, and chest 3 ms resultant acceleration, HIC15, and neck forces and moments of a Q1 anthropomorphic test device (ATD) seated in the restraints were measured. The effect of incorrect use on each outcome and restraint type was analyzed. RESULTS: The influence of errors varied across different outcome variables, the three restraints tested and orientation modes. Excursion increased in four of five incorrect use conditions in both rearward and forward-facing orientations. A very loose harness increased four of five outcome variables in at least one forward-facing restraint, whereas only excursion was increased when rearward-facing. Overall, there tended to be a more negative effect of incorrect use (demonstrated through increases in outcome variables compared to the baseline) in the forward-facing orientation. CONCLUSIONS: Overall, errors in use tended to have a larger negative impact on forward-facing restraints than rearward-facing restraints. Given the widespread nature of errors in use, this adds further weight to arguments to keep children rearward-facing to 12 months of age and older. The results also highlight a variation in response to errors across differently designed restraints, suggesting the influence of errors may be minimized by restraint design that is more resistant to errors.


Assuntos
Sistemas de Proteção para Crianças , Traumatismos Craniocerebrais , Acidentes de Trânsito , Fenômenos Biomecânicos , Criança , Desenho de Equipamento , Humanos , Lactente
15.
J Pediatr Endocrinol Metab ; 35(6): 733-740, 2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35437976

RESUMO

OBJECTIVES: Prader-Willi syndrome (PWS) is a complex genetic disorder with severe hypotonia, failure to thrive, childhood obesity, hypogonadism/hypogenitalism and learning/behavioral problems with endocrine-related growth and other hormone deficiencies. The prevalence of central adrenal insufficiency (CAI) using dynamic testing ranges from rare to 60%. We compared routine morning plasma cortisol (MPC) and ACTH levels in large cohorts of PWS and control children to address CAI. METHODS: Retrospective analysis of MPC and ACTH levels was undertaken in 128 PWS growth hormone (GH)-treated children under medical care before considering dynamic testing for CAI and 128 non-syndromic control children with short stature evaluated for GH deficiency. RESULTS: The average MPC level in PWS was 9.7 ± 3.7 µg/dL with no difference in age, gender or PWS genetic subtype and 13.4 ± 5.7 µg/dL in the control group. MPC levels were significantly lower (p < 0.05) in PWS but in the normal range. The morning plasma ACTH level in the PWS group was 22.1 ± 8.0 pg/mL with one individual having an initial low plasma ACTH level (8 pg/mL), but normal upon repeat. CONCLUSIONS: MPC levels in PWS are normal and comparable with control children, without evidence or increased risk of CAI. Lower but normal MPC levels were seen in PWS and suggestive of reduced local regeneration of cortisol from cortisone in adipose tissue by the GH-IGF-I system. Hence, MPC measures alone or in combination with ACTH should be considered for initial screening for CAI in PWS but prior to dynamic testing.


Assuntos
Insuficiência Adrenal , Hormônio do Crescimento Humano , Obesidade Infantil , Síndrome de Prader-Willi , Insuficiência Adrenal/diagnóstico , Insuficiência Adrenal/epidemiologia , Insuficiência Adrenal/etiologia , Hormônio Adrenocorticotrópico , Criança , Humanos , Hidrocortisona , Síndrome de Prader-Willi/complicações , Síndrome de Prader-Willi/diagnóstico , Estudos Retrospectivos
16.
Dent Mater ; 37(7): 1073-1082, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33849757

RESUMO

OBJECTIVE: To test the impact of three varying step-stress protocols on the fatigue behavior of two 3Y-TZP, one 4Y-TZP and one 5Y-TZP zirconia materials. METHODS: Eight specimens per zirconia material (N = 32) were selected for static testing to determine the start load for dynamic tests (30% of the mean value of static fracture load). 45 specimens per material (N = 180) were used for dynamic load tests using three step-stress protocols: 1. 50 N/5000 cycles; 2. 5% of static load/5000 cycles, and 3. 10 N/1000 cycles. Following materials were tested: 3Y-TZP(<0.25 Al2O3) (O: opaque) 3Y-TZP(<0.05 Al2O3) (T: translucent), 4Y-TZP(<0.01 Al2O3) (ET: extra translucent) and 5Y-TZP(<0.01 Al2O3) (HT: high translucent). The specimens (4 ± 0.02 × 3 ± 0.02 × 45 mm) were placed centrally on the support rolls and the load was applied perpendicularly over the 4 mm specimen side (∼4-point flexural strength according to the DIN 6872:2019). Data was analyzed with Kolmogorov-Smirnov-test, t-test, one-way ANOVA with post-hoc Scheffé-test, Chi-square-test, Kaplan-Meier with Log-Rank-test and two-parametric Weibull analysis (p < 0.05). RESULTS: The step-stress protocols showed no impact on the fracture load or Weibull modulus within one zirconia material. However, the zirconia materials T, ET and HT showed differences in cycle number to fracture between the step-stress protocols (T: 3 > 2 > 1; ET: 2 > 3 > 1; HT: 2, 3 > 1) with lowest cycle number to fracture for protocol 1. Within one step-stress protocol, the cycle number to fracture varied according to the zirconia material as follows: 1: T, O ≥ O, ET > HT; 2: ET > O, T, HT; 3: O, T, ET > HT. Cracking started at the tensile side of the specimens at all times. All specimens showed typical compression curls (single or double). Fragmentation patterns were similar for all materials with a lot of crack branching and fragmentation due to secondary cracks indicating high energy fractures. SIGNIFICANCE: Dynamic fatigue tests seem to provide important information on the long-term stability of zirconia materials. Zirconia materials with higher opacity seem to be more robust towards varying step-stress protocols than translucent zirconia materials. Regarding expenditure of time, a step-stress protocol with a load increase of 50 N every 5000 cycles seems favorable to gain information on the long-term stability of zirconia materials.


Assuntos
Cerâmica , Zircônio , Análise do Estresse Dentário , Resistência à Flexão , Teste de Materiais , Propriedades de Superfície , Ítrio
17.
J Mech Behav Biomed Mater ; 119: 104504, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33845296

RESUMO

PURPOSE: Evaluation of the effect of three different dynamic fatigue protocols on the fracture resistance of two monolithic strength-gradient zirconia materials. MATERIALS AND METHODS: A total of 240 specimens (3 × 4 × 45 mm) was milled from two different layers (incisal and middle) of two types of strength-gradient zirconia blanks (IPS e. max ZirCAD MT Multi A2 vs. IPS e. max ZirCAD Prime A2), resulting in 60 specimens per material and layer group (IPS e. max ZirCAD MT Multi A2: incisal (MI), middle (MM); IPS e. max ZirCAD Prime A2: incisal (PI), middle (PM)). Each group was divided into one static (n = 15) and three dynamic fatigue protocols (N = 45, n = 15): i. 50 N increase every 5000 cycles ii. Increase by 5% of static fracture load every 5000 cycles iii. 10 N increase every 1000 cycles until facture. All specimens were loaded until facture in CeraTest 2 k. Kaplan-Meier, Log-Rank and Chi-squared-test as well as Weibull statistics were performed. A fractographic analysis was performed. The specimens were classified according to the number of crack origins and evaluated using the Ciba-Geigy table. RESULTS: With regard to the fracture load, in the static loading MI and PI showed a higher fracture load and in dynamic fatigue protocol 2 PI showed a lower fracture load. The number of cycles until fracture only differed within three groups: MM and MI survived a higher number of cycles in dynamic fatigue protocol 2; PI survived a higher number of cycles in dynamic fatigue protocol 2 than in protocol 1. Within dynamic fatigue protocols, PM resisted the highest number of cycles in protocol 1 and 3 and MI in protocol 2. Comparing groups, Weibull modulus differed only within the static loading, with PI showing lower values than MM and MI. Within the material groups, MI showed higher values in static loading than in dynamic fatigue protocol 1 and 2, and PI showed higher values in the dynamic fatigue protocol 3 than in static loading. With regard to fracture patterns, no differences were found between the groups. CONCLUSIONS: Dynamic fatigue protocols provide clinically relevant information on the long-term stability and reliability of monolithic strength-gradient zirconia materials. However, no definitive instructions for dynamic testing can be provided from this investigation.


Assuntos
Cerâmica , Zircônio , Desenho Assistido por Computador , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície
18.
Materials (Basel) ; 14(23)2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34885467

RESUMO

The strain rate-dependent behavior of a unidirectional non-crimp fabric (UD-NCF) carbon fiber/snap-cure epoxy composite loaded along the transverse direction under quasi-static and dynamic conditions was characterized. Transverse tension and compression tests at quasi-static and intermediate strain rates were performed using hydraulic testing machines, while a split Hopkinson pressure bar (SHPB) apparatus was used for transverse compression tests at high strain rates. A pulse shaper was used on the SHPB apparatus to ensure dynamic equilibrium was achieved and that the test specimens deformed homogenously with a nearly constant strain rate. The transverse tensile strength at a strain rate of 16 s-1 increased by 16% when compared to that at quasi-static strain rates, while distinct localized fracture surface morphology was observed for specimens tested at different strain rates. The transverse compressive yield stress and strength at a strain rate of 325 s-1 increased by 94% and 96%, respectively, when compared to those at quasi-static strain rates. The initial fracture plane orientation for the transverse compression tests was captured with high-speed cameras and found to increase with increasing strain rate. The study provides an important data set for the strain rate-dependent response of a UD-NCF composite material, while the qualitative fracture surface observations provide a deeper understanding of the failure characteristics.

19.
J Mech Behav Biomed Mater ; 112: 104041, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32891976

RESUMO

The mechanical properties of plants are important for understanding plant biomechanics and for breeding new plants that can survive in challenging environments. Thus, accurate and reliable methods are required for the determination of mechanical properties such as stiffness and Young's modulus of elasticity. Much attention has been paid to the application of static methods to plants, while dynamic methods have received considerably less attention. In the present study, a dynamic forced vibration method for mechanical characterisation of Arabidopsis inflorescence stems was developed and validated against the conventional three-point bending test. Compared to dynamic tests based on free vibration, the current method allows to determine simultaneously more than one natural frequency, thus increasing the overall accuracy of the results. In addition, this method can be applied to the top parts of the stems that are more flexible, and where application of the three-point bending test is often limited. To demonstrate one of the potential applications of this method, it was applied to evaluate the influence of turgor pressure on the mechanical properties of Arabidopsis stems. Overall, the new dynamic testing approach has been shown to provide reliable data for the local mechanical properties along the Arabidopsis inflorescence stem.


Assuntos
Arabidopsis , Fenômenos Biomecânicos , Módulo de Elasticidade , Elasticidade , Vibração
20.
Br J Educ Psychol ; 90(1): 184-205, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30868575

RESUMO

BACKGROUND: The need to focus more on children's abilities to change requires new assessment technologies in education. Process-oriented assessment can be useful in this regard. Dynamic testing has the potential to provide in-depth information about children's learning processes and cognitive abilities. AIM: This study implemented a process-oriented dynamic testing procedure to obtain information regarding children's changes in series-completion skills in a computerised test setting. We studied whether children who received a graduated prompts training would show more progression in series-completion than children who received no training, and whether trained children would use more advanced explanations of their solutions than their untrained peers. SAMPLE: Participants were 164 second-grade children with a mean age of 7;11 years. Children were split into an unguided practice or a dynamic testing condition. METHODS: The study employed a pre-test-training-post-test design. Half of the children were trained in series-completion, and the other half did not receive any feedback on their problem solving. Using item response theory analysis, we inspected the progression paths of the children in the two conditions. RESULTS AND CONCLUSIONS: Children who received training showed more progression in their series-completion skills than the children who received no training. In addition, the trained children explained their solutions in a more advanced manner, when compared with the non-trained control group. This information is valuable for educational practice as it provides a better understanding of how learning occurs and which factors contribute to cognitive changes.


Assuntos
Desempenho Acadêmico , Individualidade , Prática Psicológica , Pensamento/fisiologia , Criança , Feminino , Humanos , Masculino , Resolução de Problemas/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA