Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 572
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Mass Spectrom Rev ; 42(5): 1727-1771, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35657034

RESUMO

Environmental contamination by explosives occurs due to improper handling and disposal procedures. Explosives and their transformation products pose threat to human health and the ecosystem. Trace level detection of explosives present in different environmental matrices is a challenge, due to the interference caused by matrix components and the presence of cocontaminants. Liquid chromatography combined with tandem mass spectrometry (LC-MS/MS) is an advanced analytical tool, which is ideal for quantitative and qualitative detection of explosives and its metabolites at trace levels. This review aims to showcase the current trends in the application of LC-MS/MS for detecting explosives present in soil, sediment, and groundwater with detection limits ranging from nano to femtogram levels. Specificity and advantages of using LC-MS/MS over conventional analytical methods and various processing methods and techniques used for sample preparation are discussed in this article. Important application aspects of LC-MS/MS on environmental monitoring include site characterization and degradation evaluation. Studies on qualitative and quantitative LC-MS/MS analysis in determining the efficiency of treatment processes and contamination mapping, optimized conditions of LC and MS/MS adopted, role of different ionization techniques and mass analyzers in detection of explosives and its metabolites, relative abundance of various product ions formed on dissociation and the levels of detection achieved are reviewed. Ionization suppression, matrix effect, additive selection are some of the major factors which influence MS/MS detection. A summary of challenges and future research insights for effective utilization of this technique in the environmental monitoring of explosives are presented.

2.
Chemphyschem ; 25(7): e202400040, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38270533

RESUMO

High-energetic materials belong to two main classes: propellants and explosives. The still rather unexplored family of 1,3,5,2,4,6-trioxatriazinanes, N3O3R3, has a representative of each class. We have selected three compounds, R = H, R = CH3 and R = NO2, this last compound being known as TNTOTA, "trinitro-trioxa-triazinane". Of these compounds we have studied the conformational analysis, the nitrogen inversion, the heats of formation, and the dissociation reaction into the three monomers. In addition, the corresponding 1,3,2,4-dioxadiazetidines (N2O2R2) have also been studied.

3.
Anal Bioanal Chem ; 416(8): 1907-1922, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38332189

RESUMO

Smokeless powders (SLPs) are composed of a combination of thermolabile and non-thermolabile compounds. When analysed by GC-MS, injection conditions may therefore play a fundamental role on the characterisation of forensic samples. However, no systematic investigations have ever been carried out. This casts doubt on the optimal conditions that should be adopted in advanced profiling applications (e.g. class attribution and source association), especially when a traditional split/splitless (S/SL) injector is used. Herein, a study is reported that specifically focused on the evaluation of the liner type (Ltype) and inlet temperature (Tinj). Results showed that both could affect the exhaustiveness and repeatability of the observed chemical profiles, with Ltype being particularly sensitive despite typically not being clarified in published works. Perhaps as expected, degradation effects were observed for the most thermolabile compounds (e.g. nitroglycerin) at conditions maximising the heat transfer rates (Ltype = packed and Tinj ≥ 200 °C). However, these did not seem to be as influential as, perhaps, suggested in previous studies. Indeed, the harshest injection conditions in terms of heat transfer rate (Ltype = packed and Tinj = 260 °C) were found to lead to better performances (including better overall %RSDs and LODs) compared to the mildest ones. This suggested that implementing conditions minimising heat-induced breakdowns during injection was not necessarily a good strategy for comparison purposes. The reported findings represent a concrete step forward in the field, providing a robust body of data for the development of the next generation of SLP profiling methods.

4.
J Biomech Eng ; 146(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38071487

RESUMO

In recent conflicts, blast injury from landmines and improvised explosive devices (IEDs) has been the main mechanism of wounding and death. When a landmine or IED detonates under a vehicle (an under-body blast), the seat acceleration rapidly transmits a high load to the pelvis of the occupants, resulting in torso and pelvic injury. Pelvic fractures have high mortality rates, yet their injury mechanism has been poorly researched. Three (3) fresh-frozen male pelvic specimens were tested under axial impact loading. The pelvis was impacted mounted upside down by dropping a 12 kg mass at target impact velocities ranging from 1 to 8.6 m/s with time to peak velocity ranging from 3.8 to 5.8 ms. Resulting fractures were broadly categorized as involving a bilateral pubis rami fracture, a bilateral ischium fracture, and sacroiliac joint disruption. The study provides insights into the type and severity of pelvic injury that may occur over a range of under-body blast (UBB)-relevant loading profiles.


Assuntos
Traumatismos por Explosões , Fraturas Ósseas , Masculino , Humanos , Explosões , Pelve , Articulação Sacroilíaca , Suporte de Carga
5.
Mikrochim Acta ; 191(7): 396, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877161

RESUMO

The development of a portable analytical procedure is described for rapid sequential detection and quantification of the explosives 2,4,6-trinitrotoluene (TNT) and cyclotrimethylenetrinitramine (RDX) in forensic samples using a graphite sheet (GS). A single GS platform works as a collector of explosive residues and detector after its assembly into a 3D-printed cell. The detection strategy is based on cyclic square-wave stripping voltammetry. The cathodic scan from + 0.1 to -1.0 V with accumulation at 0.0 V enables the TNT detection (three reduction peaks), and the anodic scan from + 0.2 to + 1.55 V with accumulation at -0.9 V provides the RDX detection (two oxidation processes). Low detection limit values (0.1 µmol L-1 for TNT and 2.4 µmol L-1 for RDX) and wide linear ranges (from 1 to 150 µmol L-1 for TNT and from 20 to 300 µmol L-1 for RDX) were obtained. The sensor did not respond to pentaerythritol tetranitrate (PETN), which was evaluated as a potential interferent, because plastic explosives contain mixtures of TNT, RDX, and PETN. The GS electrode was also evaluated as a collector of TNT and RDX residues spread on different surfaces to simulate forensic scenarios. After swiping over different surfaces (metal, granite, wood, cloths, hands, money bills, and cellphone), the GS electrode was assembled in the 3D-printed cell ready to measure both explosives by the proposed method. In all cases, the presence of TNT and RDX was confirmed, attesting the reliability of the proposed device to act as collector and sensor.

6.
Sensors (Basel) ; 24(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38610252

RESUMO

Multiphoton electron extraction spectroscopy (MEES) is an advanced analytical technique that has demonstrated exceptional sensitivity and specificity for detecting molecular traces on solid and liquid surfaces. Building upon the solid-state MEES foundations, this study introduces the first application of MEES in the gas phase (gas-phase MEES), specifically designed for quantitative detection of gas traces at sub-part per billion (sub-PPB) concentrations under ambient atmospheric conditions. Our experimental setup utilizes resonant multiphoton ionization processes using ns laser pulses under a high electrical field. The generated photoelectron charges are recorded as a function of the laser's wavelength. This research showcases the high sensitivity of gas-phase MEES, achieving high spectral resolution with resonant peak widths less than 0.02 nm FWHM. We present results from quantitative analysis of benzene and aniline, two industrially and environmentally significant compounds, demonstrating linear responses in the sub-PPM and sub-PPB ranges. The enhanced sensitivity and resolution of gas-phase MEES offer a powerful approach to trace gas analysis, with potential applications in environmental monitoring, industrial safety, security screening, and medical diagnostics. This study confirms the advantages of gas-phase MEES over many traditional optical spectroscopic methods and demonstrates its potential in direct gas-trace sensing in ambient atmosphere.

7.
Molecules ; 29(16)2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39202836

RESUMO

3,4-bis(3-nitrofurazan-4-yl) furoxan (DNTF) is an explosive with excellent performance, and the use of DNTF as a high-energy component is of great significance for improving the comprehensive performance of weapons. To explore the effect of DNTF on low-melting-point molten carrier explosives, the compatibility between DNTF and other low-melting-point explosives was analyzed by differential scanning calorimetry, and mechanical sensitivity was tested. The compatibility and cohesive energy density between DNTF and other low-melting-point explosives were calculated by Materials Studio. The results showed that DNTF has good compatibility with most low-melting-point explosives, and the peak temperature change of the mixed system formed by melt-casting is not obvious. Among them, DNTF has the best compatibility with MTNP, TNT, and DNAN; moderate compatibility with DFTNAN and DNP; and the worst compatibility with DNMT. The sensitivity test results indicate that the combination of DNTF and TNT has the most significant reduction in mechanical sensitivity. DFTNAN and MTNP have better stability than DNTF and can generate strong interaction forces with DNTF. Other low-melting-point explosives mixed with DNTF have lower intermolecular forces than DNTF. The DNTF/MTNP system requires the most energy to phase change when heated compared to other mixed systems and is the least sensitive to heat. The DNTF/DNMT system has the lowest cohesive energy density and is the most sensitive to heat.

8.
Small ; 19(24): e2300157, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36916694

RESUMO

Primary explosive, as a reliable initiator for secondary explosives, is the central component of micro-initiators for modern aerospace systems and military operations. However, they are typically prepared as powders, posing potential safety risks because of the inevitable particles scattering issues in the actual working environments. Here, the fabrication of a highly adaptive bulk material of copper azide (CA)-based safe primary explosive for micro-initiators is demonstrated. This bulk material, as derived by a complete azidation reaction of the carbonized metal-organic framework/cross-linked polymer hybrid template, enables the firm embedding of active CA species in a cross-linked carbon network (denoted as CA-C). Interestingly, this CA-C bulk material demonstrates multifarious mechanical stabilities (e.g., good shock and vibration resistance, and anti-overload capacity) in the simulated working conditions. Meanwhile, the CA contents in the CA-C bulk material reached as high as 70.3%, ensuring its detonation power. As a proof of concept, CA-C bulk material assembling in a micro-detonator can efficiently detonate the secondary explosive of CL-20 under laser irradiation. This work hereby advances the fabrication of safe and powerful primary explosives for the fulfillment of safe micro-initiator in a broad range of applications in aerospace systems.

9.
Chemistry ; 29(44): e202300948, 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37216337

RESUMO

The development of liquid energetic fuels with improved properties is an important topic in space propulsion technologies. In this manuscript, a series of energetic ionic liquids incorporating a 1,2,5-oxadiazole ring and nitrate, dicyanamide or dinitramide anion was synthesized and their physicochemical properties were evaluated. The synthesized compounds were fully characterized and were found to have good thermal stabilities (up to 219 °C) and experimental densities (1.21-1.47 g cm-3 ). Advantageously, 1,2,5-oxadiazole-based ionic liquids have high combined nitrogen-oxygen contents (up to 64.4 %), while their detonation velocities are on the level of known explosive TNT, and combustion performance exceeds those of benchmark 2-hydroxyethylhydrazinium nitrate. Considering the established hypergolicity with H2 O2 in the presence of a catalyst, and insensitivity to impact, synthesized ionic liquids have strong application potential as energetic fuels for space technologies.

10.
Nanotechnology ; 34(40)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37402359

RESUMO

We present a simple, fast, and single-step approach for fabricating hybrid semiconductor-metal nanoentities through liquid-assisted ultrafast (∼50 fs, 1 kHz, 800 nm) laser ablation. Femtosecond (fs) ablation of Germanium (Ge) substrate was executed in (i) distilled water (ii) silver nitrate (AgNO3-3, 5, 10 mM) (iii) Chloroauric acid (HAuCl4-3, 5, 10 mM), yielding the formation of pure Ge, hybrid Ge-silver (Ag), Ge-gold (Au) nanostructures (NSs) and nanoparticles (NPs). The morphological features and corresponding elemental compositions of Ge, Ge-Ag, and Ge-Au NSs/NPs have been conscientiously studied using different characterization techniques. Most importantly, the deposition of Ag/Au NPs on the Ge substrate and their size variation were thoroughly investigated by changing the precursor concentration. By increasing the precursor concentration (from 3 mM to 10 mM), the deposited Au NPs and Ag NPs' size on the Ge nanostructured surface was increased from ∼46 nm to ∼100 nm and from ∼43 nm to ∼70 nm, respectively. Subsequently, the as-fabricated hybrid (Ge-Au/Ge-Ag) NSs were effectively utilized to detect diverse hazardous molecules (e.g. picric acid and thiram) via the technique of surface-enhanced Raman scattering (SERS). Our findings revealed that the hybrid SERS substrates achieved at 5 mM precursor concentration of Ag (denoted as Ge-5Ag) and Au (denoted as Ge-5Au) had demonstrated superior sensitivity with the enhancement factors of ∼2.5 × 104, 1.38 × 104(for PA), and ∼9.7 × 105and 9.2 × 104(for thiram), respectively. Interestingly, the Ge-5Ag substrate has exhibited ∼10.5 times higher SERS signals than the Ge-5Au substrate.

11.
J Fluoresc ; 33(4): 1443-1455, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36752930

RESUMO

Special attention is given to the development of rapid and sensitive detection of nitroaromatic explosives for homeland security and environmental concerns. As part of our contribution to the detection of nitroaromatic explosives, fluorescent materials (A), (B) and (C) were synthesized from the reaction of 1,2-diaminocyclohexane with pyrene-1-carbaldehyde, anthracene-9-carbaldehyde and 2-hydroxy-1-naphthaldehyde, respectively. The structures of the prepared fluorescent azomethine probes were confirmed using FTIR, 1H-NMR and 13C-NMR spectroscopies. The basis of the study is the use of the synthesized materials as fluorescent probes in the photophysical and fluorescence detection of some nitroaromatic explosives. Emission increases occurred due to aggregation caused by π-π stacking in synthesized azomethines. To measure the nitroaromatic detection capabilities of fluorescence probes, fluorescence titration experiments were performed using the photoluminescence spectroscopy. It was observed that compound A containing pyrene ring provided the best emission intensity-increasing effect due to aggregation with the lowest LOD value (14.96 µM) for the sensing of 4-nitrophenol. In compounds B and C, nitrobenzene with the lowest LOD (16.15 µM and 23.49 µM respectively) caused the most regular emission increase, followed by picric acid.

12.
J Fluoresc ; 2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37515663

RESUMO

We present the synthesis of a new oxacalix[4]arene system, DMANSOC, wherein two 5-(dimethylamino)-1-naphthalene sulfonamide subunits are attached to the lower rims of the basic oxacalix[4]arene platform. Extensive spectrophotometric studies were conducted to investigate the selectivity and sensitivity of DMANSOC towards nitroaromatic explosives. Detailed analysis of spectrophotometric data, utilizing techniques such as Stern-Volmer, Benesi-Hildebrand, Job's plot, and interference study, unequivocally demonstrated the effectiveness of DMANSOC as a highly efficient fluorescent sensor for 2,4,6-trinitrophenol explosive (TNP) detection in an aqueous medium. The sensor exhibited a linear concentration range of 7.5 µM to 50 µM, with a low detection limit of 4.64 µM and a high binding affinity of 2.45 × 104 M towards TNP. Furthermore, the efficiency of the sensor in environmental samples contaminated with TNP was evaluated, yielding excellent recovery rates. Complementary DFT calculations and molecular dynamics simulations were performed to elucidate the mechanism behind the selective fluorescence quenching of DMANSOC in the presence of TNP.

13.
J Fluoresc ; 33(1): 77-90, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36251202

RESUMO

Rapid and selective detection of nitroaromatic explosives is very important for public safety, life, and environmental health. Current instrumental techniques suffer from high cost and poor site used. In order to investigate fluorescence sensing of nitroaromatics, we prepare a new small fluorescence probe derived from pamoic acid. This study covers the synthesis of Pamoic acid based [diisopropyl 4,4'-methylenebis(3-methoxy-2-naphthoate)] (2) material and characterization of its structure. The methylation of Pamoic acid ester, which we have successfully synthesized in our previous studies, was carried out in this study. Determination of the photophysical and fluorescent nitroaromatic detection properties of the compound forms the basis of the study. Structural characterization of the synthesized compound [diisopropyl 4,4'-methylenebis(3-methoxy-2-naphthoate)] (2) was characterized using spectroscopic methods. In addition, Molecular structure of the synthesized compound was determined by single crystal X-ray diffraction studies. In the final step, compounds [diisopropyl 4,4'-methylenebis(3-hydroxy-2-naphthoate)] (1) and [diisopropyl 4,4'-methylenebis(3-methoxy-2-naphthoate)] (2) were tested as fluorescent probes for the detection of some nitroaromatic explosives. It is seen that Nitrobenzene provides the best quenching effect on the compound [diisopropyl 4,4'-methylenebis(3-hydroxy-2-naphthoate)] (1) containing the -OH group, with lowest the limit of detection (LOD) value. It was observed that Picric acid provided the best quenching effect with lowest the limit of detection (LOD) value in the compound [diisopropyl 4,4'-methylenebis(3-methoxy-2-naphthoate)] (2) obtained by methylation of the -OH group in the compound [diisopropyl 4,4'-methylenebis(3-hydroxy-2-naphthoate)] (1).

14.
J Fluoresc ; 2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37486560

RESUMO

A fluorescent sensor, 5-((2-hydroxynaphthalen-1-yl)methyleneamino)benzene-1,3-dicarboxylic acid (coded as SB), containing both π-π interacting sites (such as π-electron-rich moieties) and hydrogen bonding (H-bonding) interacting sites (such as highly acidic protons) has been developed via high yield reflux method. It was characterized by the various analytical techniques such as Fourier transform-infrared spectroscopy (FT-IR), proton nuclear magnetic resonance (1 H-NMR), thermogravimetric analysis (TGA), field emission scanning electron microscope (Fe-SEM), elemental mapping, and UV - visible spectroscopy etc. The spectral response of the as-synthesized SB sensor has been investigated for various nitro explosives (NEs). It has been found that the SB sensor selectively and sensitive sense highly toxic 2,4,6-trinitrophenol (TNP) via the "turn-off" quenching response. Its limit of detection for TNP was calculated to be 30 ppb. Spectral overlap, detailed mechanistic studies for their mode of action, and density functional theory (DFT) calculations reveals that photo-induced electron transfer process (PET), fluorescence energy transfers process (FRET), and electrostatic interactions (i.e. H-bonding) are the key factors for the turn-off response of SB towards TNP. Notably, the synthesis of the sensor is cost-effective, energy efficient, and economic.

15.
Environ Res ; 236(Pt 2): 116769, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37517500

RESUMO

Considering the formidable explosive power and human carcinogenicity of nitroaromatic explosives, the implementation of an accurate and sensitive detection technology is imperative for ensuring public safety and monitoring post-blast environmental contamination. In the present work, a versatile and selective electrochemical sensor based on dummy molecularly imprinted poly (3,4-ethylenedioxythiophene)/laser-induced graphene (MIPEDOT/LIG) was successfully developed and the specific detection of multiple nitroaromatic explosives was realized in the single sensor. The accessible and nontoxic trimesic acid (TMA) and superior 3, 4-ethylenedioxythiophene (EDOT) were selected as the dummy-template and the functional monomer, respectively. The interaction between the functional monomer and the template, and the morphology, electrochemical properties and detection performance of the sensor were comprehensively investigated by ultraviolet-visible spectroscopy, Fourier-transform infrared spectroscopy, scanning electron microscopy, cyclic voltammetry, and differential pulse voltammetry. Benefiting from the alliance of TMA and EDOT, the MIPEDOT/LIG sensor manifested outstanding selectivity and sensitivity for 2,4,6-trinitrotolueen (TNT), 2,4,6-trinitrophenol (TNP), 2,4-dinitrotoluene (DNT), 1,3,5-trinitrobenzene (TNB), 2,4-dinitrophenol (DNP), and 1,3-dinitrobenzene (DNB) (representative nitroaromatic explosives) with limits of determination of 1.95 ppb, 3.06 ppb, 2.49 ppb, 1.67 ppb, 1.94 ppb, and 4.56 ppb, respectively. The sensor also exhibited extraordinary reliability and convenience for environmental sample detection. Therefore, a perfect combination of versatility and selectivity in the MIPEDOT/LIG sensor was achieved. The findings of this work provide a new direction for the development of multi-target electrochemical sensors using a versatile dummy template for explosives detection.

16.
Chirality ; 35(4): 211-226, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36651721

RESUMO

Triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) are cyclic peroxides that exhibit atropisomerism resulting from restricted rotation around three peroxide bonds. As a result, one pair of enantiomers with D3 symmetry and another pair of enantiomers with C2 symmetry can be identified. Previous studies, based on mass spectrometry data and computational results, have shown that conformations of TATP with D3 and C2 symmetry can be isolated. Assuming that enantiomer samples of TATP and HMTD can be obtained with sufficient enantiopurity, we investigated their chiroptical properties, namely, optical rotatory dispersion (ORD), vibrational circular dichroism (VCD), and Raman optical activity (VROA). ORD curves and VCD spectra are seen to be very similar for D3 - and C2 -symmetric atropisomers with the same overall helicity. Predicted VROA results, however, show significant differences between D3 - and C2 -symmetric atropisomers with the same overall helicity. The D3 -symmetric atropisomer is predicted to exhibit considerably larger magnitude vibrational optical activity signals than the C2 -symmetric atropisomer.

17.
Sensors (Basel) ; 23(13)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37448049

RESUMO

Already for some decades lateral flow assays (LFAs) are 'common use' devices in our daily life. Also, for forensic use LFAs are developed, such as for the analysis of illicit drugs and DNA, but also for the detection of explosives and body fluid identification. Despite their advantages, including ease-of-use, LFAs are not yet frequently applied at a crime scene. This review describes (academic) developments of LFAs for forensic applications, focusing on biological and chemical applications, whereby the main advantages and disadvantages of LFAs for the different forensic applications are summarized. Additionally, a critical review is provided, discussing why LFAs are not frequently applied within the forensic field and highlighting the steps that are needed to bring LFAs to the forensic market.


Assuntos
Líquidos Corporais , Drogas Ilícitas , Medicina Legal , Bioensaio , DNA
18.
Sensors (Basel) ; 23(8)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37112149

RESUMO

There is an ongoing forensic and security need for rapid, on-scene, easy-to-use, non-invasive chemical identification of intact energetic materials at pre-explosion crime scenes. Recent technological advances in instrument miniaturization, wireless transfer and cloud storage of digital data, and multivariate data analysis have created new and very promising options for the use of near-infrared (NIR) spectroscopy in forensic science. This study shows that in addition to drugs of abuse, portable NIR spectroscopy with multivariate data analysis also offers excellent opportunities to identify intact energetic materials and mixtures. NIR is able to characterize a broad range of chemicals of interest in forensic explosive investigations, covering both organic and inorganic compounds. NIR characterization of actual forensic casework samples convincingly shows that this technique can handle the chemical diversity encountered in forensic explosive investigations. The detailed chemical information contained in the 1350-2550 nm NIR reflectance spectrum allows for correct compound identification within a given class of energetic materials, including nitro-aromatics, nitro-amines, nitrate esters, and peroxides. In addition, the detailed characterization of mixtures of energetic materials, such as plastic formulations containing PETN (pentaerythritol tetranitrate) and RDX (trinitro triazinane), is feasible. The results presented illustrate that the NIR spectra of energetic compounds and mixtures are sufficiently selective to prevent false-positive results for a broad range of food-related products, household chemicals, raw materials used for the production of home-made explosives, drugs of abuse, and products that are sometimes used to create hoax improvised explosive devices. However, for frequently encountered pyrotechnic mixtures, such as black powder, flash powder, and smokeless powder, and some basic inorganic raw materials, the application of NIR spectroscopy remains challenging. Another challenge is presented by casework samples of contaminated, aged, and degraded energetic materials or poor-quality HMEs (home-made explosives), for which the spectral signature deviates significantly from the reference spectra, potentially leading to false-negative outcomes.


Assuntos
Substâncias Explosivas , Espectroscopia de Luz Próxima ao Infravermelho , Pós , Nitratos , Ciências Forenses
19.
Sensors (Basel) ; 23(19)2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37837094

RESUMO

Due to the characteristics of peroxide explosives, which are difficult to detect via conventional detection methods and have high explosive power, a fluorescent photoelectric detection system based on fluorescence detection technology was designed in this study to achieve the high-sensitivity detection of trace peroxide explosives in practical applications. Through actual measurement experiments and numerical simulation methods, the derivative dynamic time warping (DDTW) algorithm and the Spearman correlation coefficient were used to calculate the DDTW-Spearman distance to achieve time series correlation measurements. The detection sensitivity of triacetone triperoxide (TATP) and H2O2 was studied, and the detection of organic substances of acetone, acetylene, ethanol, ethyl acetate, and petroleum ether was carried out. The stability and specific detection ability of the fluorescent photoelectric detection system were determined. The research results showed that the fluorescence photoelectric detection system can effectively identify the detection data of TATP, H2O2, acetone, acetonitrile, ethanol, ethyl acetate, and petroleum ether. The detection limit of 0.01 mg/mL of TATP and 0.0046 mg/mL of H2O2 was less than 10 ppb. The time series similarity measurement method improves the analytical capabilities of fluorescence photoelectric detection technology.

20.
Sensors (Basel) ; 23(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37896679

RESUMO

Detecting trace amounts of explosives is important for maintaining national security due to the growing threat of terror attacks. Particularly challenging is the increasing use of homemade explosives. Therefore, there is a constant need to improve existing technologies for detecting trace amounts of explosives. This paper describes the design of a stationary device (a gate) for detecting trace amounts of explosives and explosive taggants and the design of differential ion mobility spectrometers with a focus on the gas system. Nitromethane (NM), trimeric acetone peroxide (TATP), hexamine peroxide (HMTD), and explosive taggants 2,3-dimethyl-2,3-dinitrobutane (DMDNB) and 4-nitrotoluene (4NT) were used in this study. Gate measurements were carried out by taking air from the hands, pocket area, and shoes of the tested person. Two differential ion mobility spectrometers operating in two different modes were used as explosive detectors: a mode with a semi-permeable membrane to detect explosives with high vapor pressures (such as TATP) and a mode without a semi-permeable membrane (using direct introduction of the sample into the measuring chamber) to detect explosives with low vapor pressures (such as HMTD). The device was able to detect trace amounts of selected explosives/explosive taggants in 5 s.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA