Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 285
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Immunol Rev ; 313(1): 262-278, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36110036

RESUMO

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare clonal, not malignant, hematological disease characterized by intravascular hemolysis, thrombophilia and bone marrow failure. While this latter presentation is due to a T-cell mediated auto-immune disorder resembling acquired aplastic anemia, the first two clinical presentations are largely driven by the complement pathway. Indeed, PNH is characterized by a broad impairment of complement regulation on affected cells, which is due to the lack of the complement regulators CD55 and CD59. The deficiency of these two proteins from PNH blood cells is due to the somatic mutation in the phosphatidylinositol N-acetylglucosaminyltransferase subunit A gene causing the disease, which impairs the surface expression of all proteins linked via the glycosylphosphatidylinositol anchor. The lack of the complement regulators CD55 and CD59 on PNH erythrocytes accounts for the hallmark of PNH, which is the chronic, complement-mediated intravascular hemolysis. This hemolysis results from the impaired regulation of the alternative pathway upstream in the complement cascade, as well as of the downstream terminal pathway. PNH represented the first indication for the development of anti-complement agents, and the therapeutic interception of the complement cascade at the level of C5 led to remarkable changes in the natural history of the disease. Nevertheless, the clinical use of an inhibitor of the terminal pathway highlighted the broader derangement of complement regulation in PNH, shedding light on the pivotal role of the complement alternative pathway. Here we review the current understanding of the role of the alternative pathway in PNH, including the emergence of C3-mediated extravascular hemolysis in PNH patients on anti-C5 therapies. These observations provide the rationale for the development of novel complement inhibitors for the treatment of PNH. Recent preclinical and clinical data on proximal complement inhibitors intercepting the alternative pathway with the aim of improving the treatment of PNH are discussed, together with their clinical implications which are animating a lively debate in the scientific community.


Assuntos
Hemoglobinúria Paroxística , Humanos , Hemoglobinúria Paroxística/tratamento farmacológico , Hemólise , Anticorpos Monoclonais Humanizados/uso terapêutico , Proteínas do Sistema Complemento , Inativadores do Complemento/uso terapêutico , Antígenos CD55
2.
Semin Immunol ; 59: 101618, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35764467

RESUMO

The treatment of paroxysmal nocturnal hemoglobinuria (PNH) was revolutionized by the introduction of the anti-C5 agent eculizumab, which resulted in sustained control of intravascular hemolysis, leading to transfusion avoidance and hemoglobin stabilization in at least half of all patients. Nevertheless, extravascular hemolysis mediated by C3 has emerged as inescapable phenomenon in PNH patients on anti-C5 treatment, frequently limiting its hematological benefit. More than 10 years ago we postulated that therapeutic interception of the complement cascade at the level of C3 should improve the clinical response in PNH. Compstatin is a 13-residue disulfide-bridged peptide binding to both human C3 and C3b, eventually disabling the formation of C3 convertases and thereby preventing complement activation via all three of its activating pathways. Several generations of compstatin analogs have been tested in vitro, and their clinical evaluation has begun in PNH and other complement-mediated diseases. Pegcetacoplan, a pegylated form of the compstatin analog POT-4, has been investigated in two phase I/II and one phase III study in PNH patients. In the phase III study, PNH patients with residual anemia already on eculizumab were randomized to receive either pegcetacoplan or eculizumab in a head-to-head comparison. At week 16, pegcetacoplan was superior to eculizumab in terms of hemoglobin change from baseline (the primary endpoint), as well as in other secondary endpoints tracking intravascular and extravascular hemolysis. Pegcetacoplan showed a good safety profile, even though breakthrough hemolysis emerged as a possible risk requiring additional attention. Here we review all the available data regarding this innovative treatment that has recently been approved for the treatment of PNH.


Assuntos
Hemoglobinúria Paroxística , Humanos , Hemoglobinúria Paroxística/tratamento farmacológico , Hemólise , Complemento C3/metabolismo , Ativação do Complemento , Hemoglobinas/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Am J Respir Cell Mol Biol ; 71(2): 219-228, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38669465

RESUMO

The bone marrow is a specialized niche responsible for the maintenance of hematopoietic stem and progenitor cells during homeostasis and inflammation. Recent studies, however, have extended this essential role to the extramedullary and extravascular lung microenvironment. Here, we provide further evidence for a reservoir of hematopoietic stem and progenitor cells within the lung from Embryonic Day 18.5 until adulthood. These lung progenitors display distinct microenvironment-specific developmental kinetics compared with their bone marrow counterparts, exemplified by a rapid shift from a common myeloid to a megakaryocyte-erythrocyte progenitor-dominated niche with increasing age. In adult mice, influenza A viral infection results in a transient reduction in multipotent progenitors within the lungs, with a parallel increase in downstream granulocyte-monocyte progenitors and dendritic cell populations associated with acute viral infections. Our findings suggest that lung hematopoietic progenitors play a role in reestablishing immunological homeostasis in the respiratory mucosa, which may have significant clinical implications for maintaining pulmonary health after inflammatory perturbation.


Assuntos
Células-Tronco Hematopoéticas , Vírus da Influenza A , Pulmão , Camundongos Endogâmicos C57BL , Infecções por Orthomyxoviridae , Animais , Células-Tronco Hematopoéticas/virologia , Células-Tronco Hematopoéticas/metabolismo , Pulmão/virologia , Pulmão/patologia , Infecções por Orthomyxoviridae/virologia , Infecções por Orthomyxoviridae/imunologia , Infecções por Orthomyxoviridae/patologia , Camundongos , Cinética
4.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
5.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047465

RESUMO

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Assuntos
Desfibriladores Implantáveis , Humanos , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
6.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39210643

RESUMO

AIMS: The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far. METHODS AND RESULTS: This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies. Patients with a successful EV ICD implant who underwent lead removal were included. The main objective was lead removal success. Ancillary objectives included characterizing technique used, procedure complications, and reimplantation status. An EV ICD system was successfully implanted in 347 patients across the 3 studies (25.9% female; 53.4 ± 13.3 years; left ventricular ejection fraction: 39.7 ± 15.9). Of these patients, 29 (8.4%) underwent lead removal with a mean lead dwell time of 12.6 ± 14.3 months (0.2-58.4). The main reason for lead removal was lead dislodgement (n = 9, 31.0%). Lead removal was successful in 27/29 (93.1%) cases [100% (19/19) success rate <1 year and 80% (8/10) success rate >1 year post-implant]. Simple traction was used in 22/26 (84.6%) and extraction tools in 4/26 (15.4%) successful cases where technique was known. No complications were reported for any of the removal procedures. All 11 EV ICD reimplant attempts were successful. CONCLUSION: Complete removal of the EV ICD lead was successful in 93.1% of cases, and simple traction was sufficient in most instances. Based on these results, lead removal from the substernal space was safe and achievable up to 3 years post-implant.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Humanos , Remoção de Dispositivo/métodos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Projetos Piloto , Fatores de Tempo , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
7.
Artigo em Inglês | MEDLINE | ID: mdl-38895976

RESUMO

BACKGROUND: The use of intranasal dexmedetomidine is hampered by a limited understanding of its absorption pharmacokinetics. METHODS: We examined the pharmacokinetics and feasibility of intranasal dexmedetomidine administered in the supine position to adult patients undergoing general anaesthesia. Twenty-eight patients between 35 and 80 years of age, ASA 1-3 and weight between 50 and 100 kg, who underwent elective unilateral total hip or knee arthroplasty under general anaesthesia were recruited. All patients received 100 µg of intranasal dexmedetomidine after anaesthesia induction. Six venous blood samples (at 0, 5, 15, 45, 60, 240 min timepoints from dexmedetomidine administration) were collected from each patient and dexmedetomidine plasma concentrations were measured. Concentration-time profiles after nasal administration were pooled with earlier data from a population analysis of intravenous dexmedetomidine (n = 202) in order to estimate absorption parameters using nonlinear mixed effects. Peak concentration (CMAX) and time (TMAX) were estimated using simulation (n = 1000) with parameter estimates and their associated variability. RESULTS: There were 28 adult patients with a mean (SD) age of 66 (8) years and weight of 83 (10) kg. The mean weight-adjusted dose of dexmedetomidine was 1.22 (0.15) µg kg-1. CMAX 0.273 µg L-1 was achieved at 98 min after intranasal administration (TMAX). The relative bioavailability of dexmedetomidine was 80% (95% CI 75-91%). The absorption half-time (TABS = 120 min; 95% CI 90-147 min) was slower than that in previous pharmacokinetic studies on adult patients. Perioperative haemodynamics of all patients remained stable. CONCLUSIONS: Administration of intranasal dexmedetomidine in the supine position during general anaesthesia is feasible with good bioavailability. This administration method has slower absorption when compared to awake patients in upright position, with consequent concentrations attained after TMAX for several hours.

8.
BMC Med Imaging ; 24(1): 40, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38347469

RESUMO

PURPOSE: Both of extracellular extravascular volume (EEV) and extracellular volume fraction (ECV) were proposed to quantify enlargement of myocardial interstitial space due to myocardium loss or fibrosis. The study aimed to investigate the feasibility of using EEV derived from myocardial computed tomography (CT) perfusion imaging (VPCT) and extracellular volume quantification with single-energy subtraction CT (ECV- SECT) for quantifying myocardial fibrosis. METHODS: In this study, 17 patients with suspected and known coronary artery disease underwent examination using a dual-source CT scanner. The EEV- VPCT was derived from dynamic whole-heart myocardial perfusion imaging, and the ECV_SECT was calculated from late-enhanced images 5 min after bolus contrast injection by subtracting the noncontrast baseline. The late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) imaging was used as a reference. RESULTS: In total, 11 patients and 73 segments exhibited positivity for LGE on CMR imaging. These were classified into three groups according to the segments: fibrotic segments (group I, n = 73), nonfibrotic segments in LGE-positive patients (group II, n = 103), and segments in LGE-negative patients (group III, n = 80). ECV- SECT, EEV- VPCT, myocardial blood flow (MBF), and myocardial blood volume (MBV) significantly differed among these groups (all P < 0.05). ECV- SECT was significantly higher and EEV- VPCT, MBF, and MBV were significantly lower in fibrotic myocardial segments than in nonfibrotic ones (all P < 0.01). ECV- SECT and EEV- VPCT independently affected myocardial fibrosis. There was no significant correlation between ECV- SECT and EEV- VPCT. The capability of EEV- VPCT to diagnose myocardial fibrosis was equivalent to that of ECV- SECT (area under the curve: 0.798 vs. 0.806, P = 0.844). ECV- SECT of > 41.2% and EEV- VPCT of < 10.3% indicated myocardial fibrosis. CONCLUSIONS: EEV- VPCT is actually first-pass distribution volume that can feasibly be used to quantify myocardial fibrosis. Furthermore, the diagnostic efficacy of EEV- VPCT is comparable to that of ECV- SECT.


Assuntos
Cardiomiopatias , Imagem de Perfusão do Miocárdio , Humanos , Meios de Contraste , Imagem de Perfusão do Miocárdio/métodos , Gadolínio , Miocárdio/patologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Fibrose , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos
9.
BMC Nephrol ; 25(1): 271, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39182042

RESUMO

BACKGROUND: Central venous occlusion (CVO) is difficult to treat with percutaneous transluminal angioplasty because the guidewire cannot pass through the occluded segments. In this study, we devised a new method for establishing an extra-anatomic bypass between the right subclavian vein and the superior vena cava via a covered stent to treat whole-segment occlusion of the right brachiocephalic vein (BCV) with calcification. CASE PRESENTATION: We present the case of a 58-year-old female patient who complained of right arm swelling present for 1.5 years. Twelve years prior, the patient began hemodialysis because chronic glomerulonephritis had progressed to end-stage renal disease. During the first 3 years, a right internal jugular vein (IJV)-tunneled cuffed catheter was used as the dialysis access, and the catheter was replaced once. A left arteriovenous fistula (AVF) was subsequently established. Owing to occlusion of the left AVF, a new fistula was established on the right upper extremity 1.5 years prior to this visit. Angiography of the right upper extremity revealed complete occlusion of the right BCV and IJV with calcification. Because of the failure to pass the guidewire across the lesion, we established an extra-anatomic bypass between the right subclavian vein and the superior vena cava with a covered stent. Angiography confirmed the patency of whole vascular access system. After 3 months of follow-up, the patient's AVF function and the bypass patency were satisfactory. CONCLUSIONS: As a new alternative for the treatment of long, angled CVO with or without calcification, a covered stent can be used to establish an extravascular bypass between central veins.


Assuntos
Stents , Humanos , Feminino , Pessoa de Meia-Idade , Veias Braquiocefálicas/cirurgia , Veias Braquiocefálicas/diagnóstico por imagem , Veia Subclávia/diagnóstico por imagem , Veia Subclávia/cirurgia , Veia Cava Superior/cirurgia , Diálise Renal , Resultado do Tratamento , Cateterismo Venoso Central , Falência Renal Crônica/terapia , Falência Renal Crônica/complicações
10.
BMC Anesthesiol ; 24(1): 331, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39289607

RESUMO

BACKGROUND: Hysteroscopic surgery is a safe procedure used for diagnosing and treating intrauterine lesions, with a low rate of intraoperative complications. However, it is important to be cautious as fluid overload can still occur when performing any hysteroscopic surgical technique. CASE PRESENTATION: In this case report, we present a unique instance where lung ultrasound was utilized to diagnose pulmonary edema in a patient following a hysteroscopic myomectomy procedure. The development of pulmonary edema was attributed to the excessive absorption of fluid during the surgical intervention. By employing lung ultrasound as a diagnostic tool, we were able to promptly identify and address the pulmonary edema. As a result, the patient received timely treatment with no complications. This case highlights the importance of utilizing advanced imaging techniques, such as lung ultrasound, in the perioperative management of patients undergoing hysteroscopic procedures. CONCLUSIONS: This case report underscores the significance of early detection and intervention in preventing complications associated with fluid overload during hysteroscopic myomectomy procedures.


Assuntos
Histeroscopia , Edema Pulmonar , Ultrassonografia , Miomectomia Uterina , Humanos , Feminino , Edema Pulmonar/etiologia , Edema Pulmonar/diagnóstico por imagem , Histeroscopia/métodos , Miomectomia Uterina/efeitos adversos , Miomectomia Uterina/métodos , Ultrassonografia/métodos , Adulto , Pulmão/diagnóstico por imagem , Neoplasias Uterinas/cirurgia , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/etiologia
11.
Artigo em Inglês | MEDLINE | ID: mdl-39278733

RESUMO

Coronary circulation plays an essential role in delivering oxygen and metabolic substrates to satisfy the considerable energy demand of the heart. This article reviews the history that led to the current understanding of coronary physiology, beginning with William Harvey's revolutionary discovery of systemic blood circulation in the 17th century, and extending through the 20th century when the major mechanisms regulating coronary blood flow (CBF) were elucidated: extravascular compressive forces, metabolic control, pressure-flow autoregulation, and neural pathways. Pivotal research studies providing evidence for each of these mechanisms are described, along with their clinical correlates. The authors describe the major role played by researchers in the 19th century, who formulated basic principles of hemodynamics, such as Poiseuille's law, which provided the conceptual foundation for experimental studies of CBF regulation. Targeted research studies in coronary physiology began in earnest around the turn of the 20th century. Despite reliance on crude experimental techniques, the pioneers in coronary physiology made groundbreaking discoveries upon which our current knowledge is predicated. Further advances in coronary physiology were facilitated by technological developments, including methods to measure phasic CBF and its regional distribution, and by biochemical discoveries, including endothelial vasoactive molecules and adrenergic receptor subtypes. The authors recognize the invaluable contribution made by basic scientists toward the understanding of CBF regulation, and the enormous impact that this fundamental information has had on improving clinical diagnosis, decision-making, and patient care.

12.
Ren Fail ; 46(1): 2353351, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38757707

RESUMO

OBJECTIVE: To investigate the feasibility and efficacy of combining ultrasound-guided sharp needle technique with percutaneous transluminal angioplasty (PTA) for treating outflow stenosis or dysfunction in arteriovenous fistula (AVF) among hemodialysis patients. METHODS: From October 2021 to March 2023, patients with occluded or malfunctional fistula veins not amenable to regularly angioplasty were retrospectively enrolled in the study. They underwent ultrasound-guided sharp needle intervention followed by PTA. Data on the location and length between the two veins, technical success, clinical outcomes, and complications were collected. Patency rates post-angioplasty were calculated through Kaplan-Meier analysis. RESULTS: A total of 23 patients were included. The mean length of the reconstructed extraluminal segment was 3.18 cm. The sharp needle opening was performed on the basilic vein (60.9%), brachial vein (26.1%), or upper arm cephalic vein (13%) to create outflow channels. Postoperatively, all cases presented with mild subcutaneous hematomas around the tunneling site and minor diffuse bleeding. The immediate patency rate for the internal fistulas was 100%, with 3-month, 6-month, and 12-month patency rates at 91.3%, 78.3%, and 43.5%, respectively. CONCLUSION: Sharp needle technology merged with PTA presents an effective and secure minimally invasive method for reconstructing the outflow tract, offering a new solution for recanalizing high-pressure or occluded fistulas.


Assuntos
Derivação Arteriovenosa Cirúrgica , Diálise Renal , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular , Humanos , Feminino , Masculino , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/métodos , Pessoa de Meia-Idade , Diálise Renal/métodos , Estudos Retrospectivos , Idoso , Adulto , Agulhas , Angioplastia/métodos , Oclusão de Enxerto Vascular/etiologia , Estudos de Viabilidade , Resultado do Tratamento
13.
Neth Heart J ; 32(10): 356-362, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39158682

RESUMO

INTRODUCTION: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking. OBJECTIVE: To assess real-world nationwide trends in EVD adoption in the Netherlands. METHODS: Using the Netherlands Heart Registration, all consecutive patients with a de novo S­ICD or conventional single-chamber ICD implantation between 2012-2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014-2020 were included. Trends in adoption are described for various patient and centre characteristics. RESULT: From 2012-2020, 2190 S­ICDs and 10,683 conventional ICDs were implanted; from 2014-2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S­ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S­ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S­ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001). CONCLUSION: This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S­ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S­ICD use is expanding beyond those centres.

14.
Indian J Crit Care Med ; 28(2): 165-169, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38323257

RESUMO

Background: Lung ultrasound (LUS) is a simple bedside tool to assess overhydration. Our study aimed to assess extravascular lung water (EVLW) using B-lines and correlate it with weaning, duration of mechanical ventilation, and mortality in critically ill patients admitted to the intensive care unit (ICU). Patients and methods: 150 mechanically ventilated ICU patients prospectively observed over 18 months, with their demographic and clinical data noted. Extravascular lung water was monitored using LUS in four intercostal spaces (ICS) from day 1 to day 5, day 7, day 10, and weekly thereafter. Pulmonary fluid burden was graded as low (1-10), moderate (11-20), and high (21-32). Weaning outcome, duration of weaning, mechanical ventilation, ICU stay, and mortality were compared in patients with and without EVLW. Results: Out of 150, 54 patients (36.0%) had EVLW. The mean lung score amongst our patients was 8.57 ± 6.0. The mean time for detection of EVLW was 1.43 ± 2.24 days. Lung score was low in 40 (26.67%) patients, moderate in 9 (6.00%) patients, and high in 5 (3.33%) patients. Incidence of weaning failure (p-value = 0.006), duration of weaning, mechanical ventilation, ICU stay (p-value < 0.0001 each), and overall mortality were significantly higher in patients with EVLW (p-value = 0.006). Conclusion: We conclude that a good proportion of critically ill patients have EVLW. Extravascular lung water significantly increases the duration of weaning, mechanical ventilation days, ICU stay, and overall mortality in critically ill patients. How to cite this article: Rajpal M, Talwar V, Krishna B, Mustafi SM. Assessment of Extravascular Lung Water Using Lung Ultrasound in Critically Ill Patients Admitted to Intensive Care Unit. Indian J Crit Care Med 2024;28(2):165-169.

15.
Catheter Cardiovasc Interv ; 101(5): 870-876, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36877810

RESUMO

PURPOSE: This study aimed to examine the feasibility and impact of extra-vascular ultrasound (EVUS)-guided intervention for infrapopliteal (IP) artery occlusive disease. MATERIALS AND METHODS: A retrospective analysis was performed using data collected from patients who underwent endovascular treatment (EVT) for IP artery occlusive disease between January 2018 and December 2020 at our institution. A total of 63 consecutive de novoocclusive lesions were compared according to the recanalization method utilized. Propensity score matching analysis was performed to compare the clinical outcomes of the methods utilized. The prognostic value was analyzed based on the technical success rate, distal puncture rate, radiation exposure, amount of contrast media, postprocedural skin perfusion pressure (SPP), and procedural complication rate. RESULTS: Eighteen matched pairs of patients were analyzed using propensity score-matched analysis. Radiation exposure was significantly lower in the EVUS-guided group than in the angio-guided group, with 135 and 287 mGy (p = 0.04) exposure on average, respectively. There were no significant differences between the two groups in terms of technical success rate, distal puncture rate, the amount of contrast media, postprocedural SPP, and procedural complication rate. CONCLUSION: EVUS-guided EVT for IP occlusive disease achieved a feasible technical success rate and significantly reduced radiation exposure.


Assuntos
Arteriopatias Oclusivas , Procedimentos Endovasculares , Humanos , Meios de Contraste , Resultado do Tratamento , Estudos Retrospectivos , Estudos de Viabilidade , Artéria Poplítea/diagnóstico por imagem , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Ultrassonografia de Intervenção/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Grau de Desobstrução Vascular
16.
Crit Care ; 27(1): 201, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237287

RESUMO

BACKGROUND: A quantitative assessment of pulmonary edema is important because the clinical severity can range from mild impairment to life threatening. A quantitative surrogate measure, although invasive, for pulmonary edema is the extravascular lung water index (EVLWI) extracted from the transpulmonary thermodilution (TPTD). Severity of edema from chest X-rays, to date is based on the subjective classification of radiologists. In this work, we use machine learning to quantitatively predict the severity of pulmonary edema from chest radiography. METHODS: We retrospectively included 471 X-rays from 431 patients who underwent chest radiography and TPTD measurement within 24 h at our intensive care unit. The EVLWI extracted from the TPTD was used as a quantitative measure for pulmonary edema. We used a deep learning approach and binned the data into two, three, four and five classes increasing the resolution of the EVLWI prediction from the X-rays. RESULTS: The accuracy, area under the receiver operating characteristic curve (AUROC) and Mathews correlation coefficient (MCC) in the binary classification models (EVLWI < 15, ≥ 15) were 0.93 (accuracy), 0.98 (AUROC) and 0.86(MCC). In the three multiclass models, the accuracy ranged between 0.90 and 0.95, the AUROC between 0.97 and 0.99 and the MCC between 0.86 and 0.92. CONCLUSION: Deep learning can quantify pulmonary edema as measured by EVLWI with high accuracy.


Assuntos
Aprendizado Profundo , Edema Pulmonar , Humanos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Raios X , Estudos Retrospectivos , Água Extravascular Pulmonar/diagnóstico por imagem , Radiografia , Termodiluição
17.
Pacing Clin Electrophysiol ; 46(9): 1066-1072, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37504377

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) provide clinically significant therapy for the prevention of sudden cardiac death. This study aimed to characterize the substernal space using computed tomography (CT) in patients with and without prior midline sternotomy to investigate the feasibility of substernal ICD lead implantation in post-sternotomy patients. METHODS: High-quality electrocardiogram-gated CT images from 100 patients (71% male, average body mass index 23.5 ± 2.9) were retrospectively collected, including 50 patients with prior midline sternotomy (S-group) and 50 patients with no prior sternotomy (NS-group). Distances were measured from the retrosternal surface to the epicardial surface of the heart and segmented into four regions from the xiphoid tip and superiorly along the sternum. RESULTS: Results generally showed a measurable but narrower average sternum-to-heart distance in the prior sternotomy group compared to the non-sternotomy group in all four regions (p < .05). In the S-group, the sternum-to-heart distances across all regions ranged from 0 to 32.0 mm, while in the NS-group, the distances ranged from 0 to 39.9 mm. CONCLUSION: Small but measurable separations between the heart and sternum were observed in patients with prior sternotomy, particularly near the xiphoid region, indicating the potential viability of extravascular substernal ICD lead implantation in post-sternotomy patients.


Assuntos
Desfibriladores Implantáveis , Esternotomia , Humanos , Masculino , Feminino , Estudos Retrospectivos , Esterno/cirurgia , Tomografia Computadorizada por Raios X
18.
Immunohematology ; 39(2): 77-81, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37405849

RESUMO

Blood transfusions are a common medical treatment. Risks arise when compatible blood is not available. This study assesses the correlation between antibody reaction strength at the antihuman globulin (AHG) phase of testing and the antibody clinical significance as predicted using the monocyte monolayer assay (MMA). Multiple examples of anti-K donor plasma samples were selected to sensitize K+k+ red blood cells (RBCs). Reactivity was confirmed by testing the sensitized K+k+ RBCs at saline-AHG. Antibody titers were determined by serial dilution using neat plasma. Sixteen samples were selected for the study based on comparable graded reactions with neat plasma (1+, 2+, 3+, and 4+) and similar titration endpoints. Each sample was used to sensitize the same Kk donor and then tested by monocytes to evaluate the clinical significance using the MMA, an in vitro procedure that mimics in vivo extravascular hemolysis to predict the survivability of incompatible transfused RBCs. The monocyte index (MI), i.e., the percentage of RBCs adhered, ingested, or both versus free monocytes, was calculated for each sample. Regardless of the reaction strength, all examples of anti-K were predicted to be clinically significant. While anti-K is known to be clinically significant, the immunogenicity rate of K ensures ample supply of antibody samples for inclusion in this project. This study demonstrates that in vitro antibody strength is highly subjective and variable. These results show no correlation between graded reaction strength at AHG and the predicted clinical significance of an antibody as assessed using the MMA.


Assuntos
Antígenos de Grupos Sanguíneos , Monócitos , Humanos , Transfusão de Sangue , Anticorpos , Eritrócitos , Isoanticorpos
19.
Int J Urol ; 30(1): 50-56, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36125952

RESUMO

OBJECTIVES: We aimed to assess the feasibility and efficacy of laparoscopic extravascular stent in treatment of nutcracker syndrome by transperitoneal or retroperitoneal approach. METHODS: Seventy-six patients with nutcracker syndrome were retrospectively enrolled from a tertiary referral center, and underwent transperitoneal (63 patients) or retroperitoneal (13 patients) laparoscopic extravascular stent from March 2011 to December 2020. Surgical parameters, complications, imaging and clinical outcomes were collected and analyzed. RESULTS: All procedures were successfully carried out without open conversion. The median operation time, estimated blood loss, and postoperative hospital day were 120 (interquartile range [IQR]: 90-144) min, 20 (IQR: 10-30) ml, and 7 (IQR: 6-9) days. At a median follow-up of 52 (range: 9-127) months, 60 (79%) patients had complete symptom resolution, 14 (18%) patients had significant symptom improvement, and 2 (3%) patients reported no symptom improvement. Ninety-four percent (50/53) of hematuria, 91% (30/33) of proteinuria, and 89% (25/28) of flank/abdominal pain resolved after extravascular LRV stenting. No significant differences were detected in surgery parameters and recovery rates of clinical symptoms between two approaches (each p > 0.05). However, patients with transperitoneal approach need longer to achieve complete recovery compared with retroperitoneal approach (8.7 vs. 1.5 months, p = 0.016). CONCLUSIONS: Laparoscopic extravascular stent performed either transperitoneally or retroperitoneally is a feasible and effective option in treatment of nutcracker syndrome. Retroperitoneal laparoscopic extravascular stent required shorter time to achieve complete recovery, which should be considered whenever possible in surgical decision-making.


Assuntos
Laparoscopia , Síndrome do Quebra-Nozes , Humanos , Veias Renais/diagnóstico por imagem , Veias Renais/cirurgia , Estudos Retrospectivos , Stents , Espaço Retroperitoneal/cirurgia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Síndrome , Síndrome do Quebra-Nozes/complicações , Síndrome do Quebra-Nozes/diagnóstico por imagem , Síndrome do Quebra-Nozes/cirurgia , Resultado do Tratamento
20.
Perfusion ; 38(6): 1240-1249, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35511059

RESUMO

OBJECTIVE: Effective therapies for the prevention of vein graft failure, which frequently occurs in coronary artery bypass grafting (CABG) due to intimal hyperplasia (IH), are still lacking. Here, we investigated the effects of the perivenous application of double-network hydrogel on vein grafts in carotid artery bypass grafting in a rabbit model. METHODS: Healthy New Zealand white rabbits were randomized into the following groups: no graft, graft, or graft + Double-network hydrogel external stent (DNHES). The rabbits' carotid artery was bypassed via the jugular vein. Double-network hydrogel external stent was wrapped around the jugular graft after the anastomoses were completed. Blood flow parameters and tissue histology of the vein grafts were evaluated. RESULTS: Compared with the untreated vein grafts at 12 weeks after the surgery, the DNHES significantly improved graft flow, attenuated intimal and medial thickening, reduced the anti-proliferating cell nuclear antigen proliferation index of the vein grafts, decreased the mRNA and protein expression of Mitogen-Activated Protein Kinase (MAPK) and Transforming Growth Factor-ß (TGF-ß), and increased the mRNA and protein expression of endothelial Nitric Oxide Synthase (eNOS). CONCLUSION: The perivenous application of DNHES exerts beneficial effects on vein grafts, reduces the inflammatory response in carotid artery bypass grafting in a rabbit model, and appears to be a safe and promising strategy to prevent vein graft failure.


Assuntos
Hidrogéis , Túnica Íntima , Coelhos , Animais , Hidrogéis/metabolismo , Hidrogéis/farmacologia , Hiperplasia/prevenção & controle , Hiperplasia/metabolismo , Hiperplasia/patologia , Túnica Íntima/patologia , Ponte de Artéria Coronária/efeitos adversos , Stents , Veias Jugulares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA