Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Sensors (Basel) ; 24(17)2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39275456

RESUMO

The temperature response of pavement is not only crucial for assessing the internal stresses within pavement structures but is also an essential parameter in pavement design. Investigating the temperature response of rubberized concrete pavements (RCP) can support the construction of large-scale rubber concrete pavements. This study constructed a pavement monitoring system based on fiber Bragg grating technology to investigate the temperature distribution, temperature strain, temperature effects, and temperature stress of RCP. The results show that the daily temperature-time history curves of concrete pavement exhibit a significant asymmetry, with the heating phase accounting for only one-third of the curve. The temperature at the middle of RCP is 1.8 °C higher than that of ordinary concrete pavement (OCP). The temperature distribution along the thickness of the pavement follows a "spindle-shaped" pattern, with higher temperatures in the center and lower temperatures at the ends. Additionally, the addition of rubber aggregates increases the temperature strain in the pavements, makes the temperature-strain hysteresis effect more pronounced, and increases the curvature of the pavement slab. However, the daily stress range at the bottom of RCP is approximately 0.7 times that of OCP.

2.
Sensors (Basel) ; 24(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38257536

RESUMO

The additive noise in the condition monitoring system using fiber Bragg grating (FBG) sensors, including white Gaussian noise and multifrequency interference, has a significantly negative influence on the fault diagnosis of rotating machinery. Spectral subtraction (SS) is an effective method for handling white Gaussian noise. However, the SS method exhibits poor performance in eliminating multifrequency interference because estimating the noise spectrum accurately is difficult, and it significantly weakens the useful information components in measured signals. In this study, an improved spectral subtraction (ISS) method is proposed to enhance its denoising performance. In the ISS method, a reference noise signal measured by the same sensing system without working loads is considered the estimated noise, the same sliding window is used to divide the power spectrums of the measured and reference noise signals into multiple frequency bands, and the formula of spectral subtraction in the standard SS method is modified. A simulation analysis and an experiment are executed by using simulated signals and establishing a vibration test rig based on the FBG sensor, respectively. The statistical results demonstrate the effectiveness and feasibility of the ISS method in simultaneously eliminating white Gaussian noise and multifrequency interference while well maintaining the useful information components.

3.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732803

RESUMO

A two-stage decoupling model based on an artificial neural network with polynomial regression is proposed for the six-component force sensor load decoupling problem in the case of multidimensional mixed loading. The six-dimensional load categorization stage model constructed in the first stage combines 63 load category label sets with a deep BP neural network. The six-dimensional load regression stage model was constructed by combining polynomial regression with a BP neural network in the second stage. Meanwhile, the six-component force sensor with a fiber Bragg grating (FBG) sensor as the sensitive element was designed, and the elastomer simulation and calibration experimental dataset was established to realize the validation of the two-stage decoupling model. The results based on the simulation data show that the accuracy of the classification stage is 93.65%. The MAPE for the force channel in the regression stage is 6.29%, and 3.24% for the moment channel. The results based on experimental data show that the accuracy of the classification stage is 87.80%. The MAPE for the force channel in the regression phase is 5.63%, and 4.82% for the moment channel.

4.
Sensors (Basel) ; 23(21)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37960408

RESUMO

Weigh-in-motion (WIM) systems are essential for efficient transportation and monitoring parameters such as vehicle number, speed, and weight to ensure regulatory compliance and enhance road safety. Recently, WIM measurements using the Glass Fiber Reinforced Polymer Fiber Bragg Grating (GFRP-FBG) sensors have shown robustness and effectiveness. However, the accuracy of weight evaluation using the WIM systems based on GFRP-FBG sensors can be significantly influenced by the vehicle-wandering effect, which introduces uncertainties in wheel position determination and weight calculations. This paper assessed the impact of vehicle wandering on the accuracy of a WIM measurement system based on GFRP-FBG sensors by utilizing a new hybrid sensor-camera system that integrates roadside cameras and in-pavement GFRP-FBG sensors. The detailed methodology and framework of the developed hybrid system are introduced, followed by field testing on Highway I-94 in the United States. The field testing results indicate that by using the hybrid system, the wheel load detection accuracy of the WIM system based on GFRP-FBG sensors can be controlled to be a Type I or Type III WIM according to the ASTM 1318E-09 standard, with an average accuracy ranging from 87.83% to 94.65%. At the same time, when the wander distance is less than or equal to 9 cm, the developed WIM system proves to be very cost-effective as it only comprises two GFRP-FBG sensors, one temperature FBG sensor, and one camera. These findings indicate the practical potential to enhance the accuracy of WIM systems based on GFRP-FBG sensors designed for highways for low-coast, reliable, and accurate measurements by addressing vehicle wandering effects.

5.
Sensors (Basel) ; 23(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37447917

RESUMO

Lumbar puncture is a minimally invasive procedure that utilizes a spinal needle to puncture the lumbar epidural space to take a sample from the cerebrospinal fluid or inject drugs for diagnostic and therapeutic purposes. Physicians rely on their expertise to localize epidural space. Due to its critical procedure, the failure rate can reach up to 28%. Hence, a high level of experience and caution is required to correctly insert the needle without puncturing the dura mater, which is a fibrous layer protecting the spinal cord. Failure of spinal anesthesia is, in some cases, related to faulty needle placement techniques since it is blindly inserted. Therefore, advanced techniques for localization of the epidural space are essential to avoid any possible side effects. As for epidural space localization, various ideas were carried out over recent years to provide accurate identification of the epidural space. Subsequently, several methodologies based on mechanical and optical schemes have been proposed. Several research groups worked from different aspects of the problem, namely, the clinical and engineering sides. Hence, the main goal of this paper is to review this research with the aim of remedying the gap between the clinical side of the problem and the engineering side by examining the main techniques in building sensors for such purposes. This manuscript provides an understanding of the clinical needs of spinal needles from an anatomical point of view. Most importantly, it discusses the mechanical and optical approaches in designing and building sensors to guide spinal needles. Finally, the standards that must be followed in building smart spinal needles for approval procedures are also presented, along with some insight into future directions.


Assuntos
Anestesia Epidural , Raquianestesia , Agulhas/efeitos adversos , Punção Espinal/efeitos adversos , Punção Espinal/métodos , Raquianestesia/efeitos adversos , Raquianestesia/métodos , Sistema Nervoso Central
6.
Chem Eng J ; 420: 127655, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-33199974

RESUMO

Monitoring the COVID-19 virus through patients' saliva is a favorable non-invasive specimen for diagnosis and infection control. In this study, salivary samples of COVID-19 patients collected from 6 patients with the median age of 58.5 years, ranging from 34 to 72 years (2 females and 4 males) were analyzed using an Au/fiber Bragg grating (FBG) probe decorated with GO. The probe measures the prevalence of positivity in saliva and the association between the virus density and changes to sensing elements. When the probe is immersed in patients' saliva, deviation of the detected light wavelength and intensity from healthy saliva indicate the presence of the virus and confirms infection. For a patient in the hyperinflammatory phase of desease, who has virus density of 1.2 × 108 copies/mL in saliva, the maximum wavelength shift and intensity changes after 1600 s were shown to be 1.12 nm and 2.01 dB, respectively. While for a patient in the early infection phase with 1.6 × 103 copies/mL, these values were 0.98 nm and 1.32 dB. The precise and highly sensitive FBG probe proposed in this study was found a reliable tool for quick detection of the COVID-19 virus within 10 s after exposure to patients' saliva in any stage of the disease.

7.
Sensors (Basel) ; 21(2)2021 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-33435496

RESUMO

Joints between diaphragm wall panels are weak spots in wall construction. It is essential that potential leak sites are detected prior to excavation. In this study, a novel leak detection and monitoring system is presented that is based on fiber Bragg grating (FBG) sensing technology. A field study was performed in a deep excavation supported by diaphragm walls (in Hohhot, China) to validate the feasibility and effectiveness of the proposed method. Two schemes were trialed; one using pipes made of stainless steel, and one used a pipeless method. The results of the field study are presented and discussed. They show that potential leak sites in the wall joints could be determined prior to excavation using the proposed detection method. Stainless steel is a good material to use to make the detection tube because it can protect the FBG sensors and heating belts from damage and is more sensitive to water leakage. The field study provides good evidence for the feasibility of the new detection system. It also provides valuable experience for the field application of the system and has generated useful data to use in follow-up work.

8.
Sensors (Basel) ; 21(16)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34450771

RESUMO

Epidural analgesia represents a clinical common practice aiming at pain mitigation. This loco-regional technique is widely used in several applications such as labor, surgery and lower back pain. It involves the injections of anesthetics or analgesics into the epidural space (ES). The ES detection is still demanding and is usually performed by the techniques named loss of resistance (LOR). In this study, we propose a novel soft system (SS) based on one fiber Bragg grating sensor (FBG) embedded in a soft polymeric matrix for LOR detection during the epidural puncture. The SS was designed to allow instrumenting the syringe's plunger without relevant modifications of the anesthetist's sensations during the procedure. After the metrological characterization of the SS, we assessed the capability of this solution in detecting LOR by carrying it out in silico and in clinical settings. For both trials, results revealed the capability of the proposed solutions in detecting the LOR and then in recording the force exerted on the plunger.


Assuntos
Analgesia Epidural , Espaço Epidural , Simulação por Computador
9.
Sensors (Basel) ; 20(19)2020 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-32987696

RESUMO

Polymer-matrix composites degrade under the influence of UV radiation in the range of the 290-400 nm band. The degradation of polymer-matrix composites exposed to UV radiation is characterized by extensive aging of the epoxy matrix, resulting in deterioration of their mechanical properties. Glass fibers/epoxy resin composites were made by an out-of-autoclave method whereas a fiber optic sensor was placed between different layers of laminates. In our work, we used a fiber Bragg grating sensor covered with graphene oxide and embedded in a polymer matrix composite to monitor UV radiation intensity. Measurements of UV radiation may allow monitoring the aging process of individual components of the polymer composite. In order to estimate the number of microcracks of epoxy resin, microstructure observations were carried out using a scanning electron microscope.

10.
Sensors (Basel) ; 20(24)2020 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-33321816

RESUMO

The FBG (Fiber Bragg grating) sensor is an optical fiber type strain sensor. When a person breathes, strain occurs in the lungs and diaphragm. This was verified using an FBG sensor to which part of the living body this respiratory strain propagates. When measured in the abdomen, the signal waveforms were significantly different between breathing and apnea. The respiratory cycle measured by the temperature sensor attached to the mask and the strain cycle measured by the FBG sensor almost matched. Respiratory strain was measured in the abdomen, chest, and shoulder, and the signal amplitude decreased with distance from the abdomen. In addition, the respiratory rate could be calculated from the measured strain signal. On the other hand, respiratory strain did not propagate to the elbows and wrists, which were off the trunk, and the respiratory time, based on the signal period, could not be calculated at these parts. Therefore, it was shown that respiratory strain propagated in the trunk from the abdomen to the shoulder, but not in the peripheral parts of the elbow and wrist.


Assuntos
Fibras Ópticas , Taxa Respiratória , Técnicas Biossensoriais , Humanos
11.
Sensors (Basel) ; 20(7)2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32235656

RESUMO

In order to examine the applicability of Fiber Bragg Grating (FBG) sensing technology in the static penetration of pipe piles, static penetration tests in clay were conducted using double-wall open and closed model pipe piles. The strain was measured using FBG sensors, and the plug height was measured using a cable displacement sensor. Using one open pile and two closed piles, the difference in pipe pile penetration was compared and analyzed. Based on FBG sensing technology and the strain data, the penetration characteristics of the pipe pile, such as axial force, lateral friction, and driving resistance were examined. Results showed that FBG sensing technology has superior testing performance for the pipe pile penetration process, can accurately reflect the strain time history of pipe piles, and can clearly reflect the penetration process of pipe piles with increasing penetration depth. In addition, the variation law of the characteristics of the jacked pile pile-soil interface was obtained. This test has significance for model tests and the engineering design of pipe piles.

12.
Sensors (Basel) ; 19(6)2019 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-30893919

RESUMO

Lamb wave (LW) is well suited for structural health monitoring (SHM) in advanced composites. However, characteristic differences between the symmetric modes and the anti-symmetric modes often add complexity to SHM systems. The anisotropic nature of composite materials, on the other hand, necessitates direction-sensitive sensing. In this paper we report the experimental demonstration of bidirectional (0° and 90°), bimodal (S0 and A0) LW measurement within the frequency range of 20⁻140 kHz using a polarization-maintaining fiber Bragg grating (PM-FBG) sensor attached to a composite laminated plate. By selectively interrogating the fast and/or the slow axis of the PM-FBG, we show that not only can the sensor respond to LWs propagating along both directions, but the response can also be used to differentiate the two directions. Moreover, the fast axis of the sensor is able to respond to both the S0 and the A0 modes when the sensor is aligned with the wave propagation direction, whereas single S0 mode response can be achieved with the slow axis operating perpendicularly to the wave propagation direction. Such diverse responses indicate the potential of PM-FBGs as versatile multi-parameter SHM detectors, which can effectively address the challenges posed by material anisotropicity and LW mode diversity.

13.
Sensors (Basel) ; 18(6)2018 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-29874847

RESUMO

The Chinese space station is designed to carry out manned spaceflight, space science research, and so on. In serious applications, it is a common operation to inject gas into the hull, which can produce strain of the bulkhead. Accurate measurement of strain for the bulkhead is one of the key tasks in evaluating the health condition of the space station. This is the first work to perform strain detection for the Chinese space station bulkhead by using optical fiber Bragg grating. In the period of measurements, the resistance strain gauge is used as the strain standard. The measurement error of the fiber optical sensor in the circumferential direction is very small, being less than 4.52 µÎµ. However, the error in the axial direction is very large with the highest value of 28.93 µÎµ. Because the measurement error of bare fiber in the axial direction is very small, the transverse effect of the substrate of the fiber optical sensor likely plays a role. The comparison of the theoretical and experimental results of the transverse effect coefficients shows that they are fairly consistent, with values of 0.0271 and 0.0287, respectively. After the transverse effect is compensated, the strain deviation in the axial detection is smaller than 2.04 µÎµ. It is of great significance to carry out real-time health assessment for the bulkhead of the space station.

14.
Sensors (Basel) ; 18(6)2018 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-29882904

RESUMO

Structure Health Monitoring is a topic of great interest in port structures due to the ageing of structures and the limitations of evaluating structures. This paper presents a cloud computing-based stability evaluation platform for a pier type port structure using Fiber Bragg Grating (FBG) sensors in a system consisting of a FBG strain sensor, FBG displacement gauge, FBG angle meter, gateway, and cloud computing-based web server. The sensors were installed on core components of the structure and measurements were taken to evaluate the structures. The measurement values were transmitted to the web server via the gateway to analyze and visualize them. All data were analyzed and visualized in the web server to evaluate the structure based on the safety evaluation index (SEI). The stability evaluation platform for pier type port structures involves the efficient monitoring of the structures which can be carried out easily anytime and anywhere by converging new technologies such as cloud computing and FBG sensors. In addition, the platform has been successfully implemented at “Maryang Harbor” situated in Maryang-Meyon of Korea to test its durability.

15.
Sensors (Basel) ; 16(10)2016 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-27669251

RESUMO

Embedded fiber Bragg grating sensors have been extensively used worldwide for health monitoring of smart structures. In civil engineering, they provide a powerful method for monitoring the performance of composite reinforcements used for concrete structure rehabilitation and retrofitting. This paper discusses the problem of investigating the strain transfer mechanism in composite strengthened concrete beams subjected to three-point bending tests. Fiber Bragg grating sensors were embedded both in the concrete tensioned surface and in the woven fiber reinforcement. It has been shown that, if interface decoupling occurs, strain in the concrete can be up to 3.8 times higher than that developed in the reinforcement. A zero friction slipping model was developed which fitted very well the experimental data.

16.
Sensors (Basel) ; 15(11): 28456-71, 2015 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-26569250

RESUMO

Pattern classification of ingestive behavior in grazing animals has extreme importance in studies related to animal nutrition, growth and health. In this paper, a system to classify chewing patterns of ruminants in in vivo experiments is developed. The proposal is based on data collected by optical fiber Bragg grating sensors (FBG) that are processed by machine learning techniques. The FBG sensors measure the biomechanical strain during jaw movements, and a decision tree is responsible for the classification of the associated chewing pattern. In this study, patterns associated with food intake of dietary supplement, hay and ryegrass were considered. Additionally, two other important events for ingestive behavior were monitored: rumination and idleness. Experimental results show that the proposed approach for pattern classification is capable of differentiating the five patterns involved in the chewing process with an overall accuracy of 94%.


Assuntos
Comportamento Alimentar/classificação , Comportamento Alimentar/fisiologia , Tecnologia de Fibra Óptica/instrumentação , Aprendizado de Máquina , Mastigação/fisiologia , Algoritmos , Animais , Fenômenos Biomecânicos , Desenho de Equipamento , Tecnologia de Fibra Óptica/métodos , Ruminantes
17.
Micromachines (Basel) ; 15(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38258147

RESUMO

The carbonation of concrete greatly affects its service life. In this paper, fiber Bragg grating (FBG) sensors were used to investigate the relationship between concrete carbonation and its mechanical properties. A T130 High Sensitivity Strain Cable Sensor with a good linearity was used to monitor the internal strain in concrete, to investigate the variation in the elastic modulus of concrete with carbonation time. A mathematical model of elastic modulus and carbonation time of concrete based on FBG was established. At the same time, the authors explored the relationship between the carbonation depth and compressive strength of concrete and the carbonation time using a phenolphthalein solution test and a compressive strength test, respectively. The experimental results indicate that the carbonation depth, compressive strength, and elastic modulus of concrete increase with carbonation time. In the early stage of carbonation, these three parameters increase rapidly, while they grow slowly in the later stage of carbonation. The varying trend of the elastic modulus of concrete is consistent with the compressive strength, which shows a binomial relationship. Therefore, the elastic modulus, measured using FBG sensors, is used as an indicator of the characterization of the carbonation resistance of concrete. This work provides a new approach for concrete carbonation detection and assessment.

18.
Heliyon ; 9(5): e15932, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37215770

RESUMO

The airborne distributed Position and Orientation System (POS) is a key piece of equipment for providing high-precision motion parameters for aerial remote sensing systems. However, wing deformation degrades the performance of distributed POS, thus, it is urgent to obtain high-precision deformation information to assist distributed POS. In this study, a modeling and calibrating method of fiber Bragg grating (FBG) sensors for wing deformation displacement measurement is proposed. First, based on the cantilever beam theory and piecewise superposition, a modeling and calibrating method for wing deformation displacement measurement is established. The wing is then placed under different deformation conditions, and the changes in the wing deformation displacement and corresponding wavelength variations of the pasted FBG sensors are obtained using theodolite coordinate measurement system and FBG demodulator, respectively. Subsequently, linear least square fitting is deployed to develop the relationship model between the wavelength variations of the FBG sensors and wing deformation displacement. Finally, the wing deformation displacement at the measuring point in the temporal and spatial dimensions is obtained by fitting and interpolation. An experiment is conducted, and the results show that the accuracy of the proposed method can reach 0.721 mm with a wing length of 3 m, which can be used in the motion compensation of an airborne distributed POS.

19.
Sensors (Basel) ; 12(5): 5888-95, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22778619

RESUMO

We propose and demonstrate a fiber Bragg grating (FBG) sensor network employing the code division multiple access (CDMA) technique to identify information from individual sensors. To detect information without considering time delays between sensors, a sliding correlation method is applied, in which two different signals with the same pseudo-random binary sequence (PRBS) pattern, but slightly different frequencies, are applied to the source and detector sides. Moreover, for time domain detection, a wavelength-to-time conversion technique using a wavelength dispersive medium is introduced. The experimental results show that the proposed sensor network has a wide strain dynamic range of 2,400 µÎµ and a low crosstalk of 950:1.

20.
Polymers (Basel) ; 14(10)2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35631865

RESUMO

Nowadays, variable preparation, forming and processing methods of fiber metal laminates are constantly developing to meet the requirements of different application fields, hence the characteristics and evolution of residual stresses under different manufacturing conditions deserve more attention. In this work, the evolution behaviors of curing residual stresses in GLARE under a hot-pressing condition were studied, and the residual stress reduction mechanism was also explained. Results suggested the FE prediction models of the entire cure process, verified by the fiber Bragg grating (FBG) sensors, were more precise than the traditional elastic model. Moreover, the stress evolution during the cure process mainly occurred in the cooling stage, in which the different coefficient of thermal expansion (CTE) of aluminum and GFRP played a major role. Meanwhile, curing shrinkage stress in the GFRP layer during the holding stage at curing temperature obviously influenced the final stress level. The residual stresses in GFRP layers differed by 9.6 MPa under a hot-pressing and autoclave condition, in which the convection heat transfer condition played a major role as it caused lower thermal stress in the holding stage and a smaller temperature gradient in the cooling stage. Considering this, a lower cooling rate could be a feasible way to obtain GLARE with lower residual stress under a hot-pressing condition.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA