1.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38000045

RESUMO

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Assuntos
Doenças Hematológicas , Hematologia , Humanos , Contagem de Células Sanguíneas , Doenças Hematológicas/diagnóstico , Leucócitos , Contagem de Leucócitos
2.
Clin Chem Lab Med ; 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39321044

RESUMO

OBJECTIVES: A smear review is typically made in flagged differential counts performed with hematology analyzers although the clinical value of such reviews is uncertain. Therefore, we evaluated the differences in differential counts between Sysmex XN-9000 and a smear review in flagged samples. Furthermore, the clinical value of blasts identified was investigated. METHODS: Data on all differential counts performed in a two-year period were identified at two laboratories. In patients with blasts, the electronic health record was reviewed. Agreement between automated and manual differential counts was evaluated by Bland-Altman plots. Concordance between the two methods categorized according to reference intervals was evaluated and adjusted for irrelevant non-concordance caused by random analytical error. RESULTS: In total, 5,500 flagged differential counts were identified from 4,092 patients. A good agreement between the automated and manual differential count was found for all cell types (-0.480 × 109/L to 0.297 × 109/L). The concordance between the two methods was excellent for all cell types, except for monocytes (82 %) where the automated estimates were higher than the manual in 19 % of samples. Blasts were identified in 241 (1 %) of smear reviews. Acute leukemia was diagnosed in 13 (5 %) patients, and only in one patient contributed the detection of blasts to the suspicion of acute leukemia. CONCLUSIONS: Our findings indicate that routine smear review of all flagged samples do not contribute with additional, significant information. After local validation and dialogue with clinical departments, such reviews may potentially be omitted to increase cost-effectiveness and reduce turn-around-time.

3.
Clin Chem Lab Med ; 62(12): 2461-2468, 2024 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-38753471

RESUMO

OBJECTIVES: Even in the current era of hematology analyzer automation and peripheral equipment, quality control sample measurement remains a manual task, leading to variability in quality control data and increased workload. In this study, we evaluated the performance of quality control measurement using the BT-50 Transportation Unit (BT-50, Sysmex, Kobe, Japan), equipped with a scheduled automatic quality control function, to ensure measurement accuracy and streamline the workflow of hematology testing. METHODS: We evaluated the automatic measurement performance of quality control samples using the BT-50 for six representative blood test parameters: WBC (white blood cell), RBC (red blood cell), HGB (hemoglobin), HCT (hematocrit), PLT (platelet), and RET% (reticulocyte percent). We evaluated the equivalence and compared measurement accuracy between the BT-50 and the manual method. We then compared the variability to other laboratories and confirmed the stability of quality control samples. We also evaluated changes in workflow and staff resources before and after the introduction of the BT-50. RESULTS: The quality control measurement results for the BT-50 and the manual method were found to be equivalent for all six parameters. The variability measured by the BT-50 was lower for some parameters compared to the manual method. Furthermore, the workflow was streamlined by reducing manual processes, resulting in increased efficiency. CONCLUSIONS: We confirmed the performance of quality control measurements using the schedule function of the BT-50. Introducing the BT-50 reduced the operator's workload, improved operational efficiency, and promoted the standardization of quality control measurements.


Assuntos
Controle de Qualidade , Humanos , Automação , Testes Hematológicos/normas , Testes Hematológicos/métodos , Automação Laboratorial/normas
4.
Clin Chem Lab Med ; 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39217753

RESUMO

OBJECTIVES: Utilizing RBC or PLT-related parameters to establish rules for the PLT-O reflex test can assist laboratories in quickly identifying specimens with interfered PLT-I that require PLT-O retesting. METHODS: Prospective PLT-I and PLT-O testing was performed on 6857 EDTA-anticoagulated whole blood samples, split randomly into training and validation cohorts at a 2:3 ratio. Reflex and non-reflex groups were distinguished based on the differences between PLT-I and PLT-O results. By comparing RBC and PLT parameter differences and flags in the training set, we pinpointed factors linked to PLT-O reflex testing. Utilizing Lasso regression, then refining through univariate and multivariate logistic regression, candidate parameters were selected. A predictive nomogram was constructed from these parameters and subsequently validated using the validation set. ROC curves were also plotted. RESULTS: Significant differences were observed between the reflex and non-reflex groups for 19 parameters including RBC, MCV, MCH, MCHC, RDW-CV, RDW-SD, Micro-RBC#, Micro-RBC%, Macro-RBC#, Macro-RBC%, MPV, PCT, P-LCC, P-LCR, PLR,"PLT clumps?" flag, "PLT abnormal histogram" flag, "IDA Anemia?" flag, and "RBC abnormal histogram" flag. After further analysis, Micro-RBC#, Macro-RBC%,"PLT clumps?", and "PLT abnormal histogram" flag were identified as candidate parameters to develop a nomogram with an AUC of 0.636 (95 %CI: 0.622-0.650), sensitivity of 42.9 % (95 %CI: 37.8-48.1 %), and specificity of 90.5 % (95 %C1: 89.6-91.3 %). CONCLUSIONS: The established rules may help laboratories improve efficiency and increase accuracy in determining platelet counts as a supplement to ICSH41 guidelines.

5.
Eur J Pediatr ; 183(10): 4477-4490, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39143348

RESUMO

Microsystems represent an alternative but proficient approach of analysis outside the laboratory, and their use could help in reducing the impact of pre-analytical errors, in particular in challenging newborn samples. The study purpose is to compare the Horiba Microsemi CRP LC-767G system for rapid 3-part complete blood count (CBC) and C-reactive protein (CRP) determination with the laboratory reference systems (respectively Sysmex XN-9100™ and Roche Cobas® c702) in samples of adult patients and newborns hospitalized in the neonatal intensive care unit (NICU) samples. The comparison between the analyzers was performed through Passing-Bablok regression analysis and Bland-Altman plot. One hundred eighty-three blood samples were analyzed. The regression analysis results, performed in the newborn (n = 70) and in adult (n = 113) populations, showed a good agreement between the instruments. The evaluation of the Bland-Altman plots showed comparable values of bias < 10% for most of the parameters, but not for MPV, lymphocyte, and monocyte count. CONCLUSION: The comparison between the Microsemi CRP LC-767G system and the laboratory instrumentations demonstrated comparable results. The Microsemi CRP LC-767G system provides reliable analytical data and faster turnaround time, particularly useful in NICU. WHAT IS KNOWN: • Microsystems for point-of-care testing (POCT) represent an alternative but proficient approach of analysis outside the laboratory, in order to perform a rapid, safe, and exhaustive evaluation for critical patients' management, acting as a valid support for treatment in acute care. WHAT IS NEW: • The Microsemi CRP LC-767G system can represent an alternative but effective testing approach outside the laboratory, particularly in NICU, to reduce the impact of pre-analytical errors on newborn samples.


Assuntos
Proteína C-Reativa , Unidades de Terapia Intensiva Neonatal , Humanos , Recém-Nascido , Proteína C-Reativa/análise , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/estatística & dados numéricos , Adulto , Masculino , Feminino , Hospitais Universitários , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
6.
J Clin Lab Anal ; 38(8): e25037, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38619294

RESUMO

BACKGROUND: In newborns, elevated nucleated red blood cell (NRBC) levels can be associated with enhanced erythropoietic stress and might be predictive for adverse outcome. Also, the presence of NRBC in peripheral blood might lead to erroneous enumeration results of white blood cells in automated hematology analyzers. We aimed to assess the comparability of the Sysmex XN 1000 to manual slide reviews and correlation of NRBC with inflammation markers. METHODS: Specimens of 3397 children under 1 year were compared by automated and microscopic NRBC enumeration. Additionally, potential correlations between NRBC and age and inflammation markers were examined. RESULTS: Overall, there was good correlation (r = 0.97) between automated (range: 0%-3883%) and microscopic enumeration (range: 0%-3694%) of NRBC with high comparability up to a NRBC value of 200% and an increase in the variation between the two methods with increasing NRBC numbers. When 94 samples with ≤ 200% NRBC and ≥ 30% divergence between methods were separately reanalyzed with respect to overlapping cell populations in their scattergrams, Sysmex would have generated unrecognized incorrect automated results in 47 samples, corresponding to 1.4% of total study samples. NRBC counts were negatively correlated to age, but not to inflammation markers. CONCLUSION: Sysmex XN 1000 is highly precise in the enumeration of NRBC in children under 1 year up to counts of 200% and might replace time-intense manual counting in routine diagnostics. In the setting of neonatal and intensive care diagnostics, microscopic control and supervision of scattergrams are highly recommended for any automated NRBC enumeration processes.


Assuntos
Eritroblastos , Humanos , Lactente , Eritroblastos/citologia , Recém-Nascido , Contagem de Eritrócitos/métodos , Feminino , Masculino , Automação Laboratorial/métodos , Microscopia/métodos
7.
Malar J ; 21(1): 229, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907857

RESUMO

BACKGROUND: The automated haematology analyzer XN-31 prototype (XN-31p) is a new flow cytometry-based device developed to measure the number and the ratio of malaria-infected red blood cells (MI-RBC) with a complete blood count (CBC). The XN-31p can provide results in about one minute and also can simultaneously provide information on the malaria parasite (Plasmodium) species. In this study, clinical testing of the XN-31p was performed using blood samples from patients with imported malaria in Japan. METHODS: Blood samples were collected from 80 patients who visited the hospital of the National Center for Global Health and Medicine, Tokyo, Japan, for malaria diagnosis from January 2017 to January 2019. The test results by the XN-31p were compared with those by other standard methods, such as microscopic observation, rapid diagnostic tests and the nested PCR. RESULTS: Thirty-three patients were diagnosed by the nested PCR as being malaria positive (28 Plasmodium falciparum, 2 Plasmodium vivax, 1 Plasmodium knowlesi, 1 mixed infection of P. falciparum and Plasmodium malariae, and 1 mixed infection of P. falciparum and Plasmodium ovale), and the other 47 were negative. The XN-31p detected 32 patients as "MI-RBC positive", which almost matched the results by the nested PCR and, in fact, completely matched with the microscopic observations. The ratio of RBCs infected with malaria parasites as determined by the XN-31p showed a high correlation coefficient of more than 0.99 with the parasitaemia counted under microscopic observation. The XN-31p can analyse the size and nucleic acid contents of each cell, and the results were visualized on a two-dimensional cytogram termed the "M scattergram". Information on species and developmental stages of the parasites could also be predicted from the patterns visualized in the M scattergrams. The XN-31p showed a positive coincidence rate of 0.848 with the nested PCR in discriminating P. falciparum from the other species. CONCLUSIONS: The XN-31p could rapidly provide instructive information on the ratio of MI-RBC and the infecting Plasmodium species. It was regarded to be of great help for the clinical diagnosis of malaria.


Assuntos
Coinfecção , Hematologia , Malária Falciparum , Malária , Humanos , Japão , Malária/parasitologia , Malária Falciparum/parasitologia , Plasmodium falciparum , Plasmodium malariae
8.
BMC Infect Dis ; 21(1): 1006, 2021 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-34565334

RESUMO

BACKGROUND: Hematology analyzers display abnormal parameters during malaria infection providing insightful information for suspecting and assessing malaria infection. The goal of this study is to demonstrate the potential of a three-part differential hematology analyzer to assess malaria, provide information about the parasitemia, and discuss the importance of combining C-reactive protein (CRP) with hematology parameters to obtain further information about the malaria infection. METHODS: The present study shows the results of a case-control study during the monsoon season of years 2018 and 2019 in Mumbai, India. The study considers 1008 non-malaria febrile cases, 209 P. vivax and 31 P. falciparum positive malaria samples, five cases of mixed P. vivax and P. falciparum infection, and three co-infection cases of P. vivax and dengue. Raw data from the three-part analyzer LC-667G CRP (HORIBA) and the corresponding microscopic findings (golden standard for diagnosis of malaria) were obtained for each sample. RESULTS: The medians of platelet counts (PLT) were 102.5, 109.0, and 223.0 × 103/µL, while CRP medians were 67.4, 81.4 and 10.4 mg/L in P. vivax, P. falciparum and control groups respectively (p < 0.001 in Mann-Whitney U tests between malaria and control groups). Compared with negative samples, platelets counting less than 161.5 × 103/µL were observed on malaria patients (OR 19.12, 95% CI 11.89-30.75). Especially in P. vivax cases, an abnormal peak was frequently observed in the white blood cells (WBC) histogram around the 37fL channel. The events counted around that channel showed a linear correlation with the counting of red blood cells infected predominantly with larger parasitic forms. Parameters like CRP (rs = 0.325, p < 0.001), WBC (rs = 0.285, p < 0.001) and PLT (rs = - 0.303, p < 0.001) were correlated with the parasitemia of P. vivax samples. Between the malaria and dengue groups, the highest area under the receiver operating characteristic curve was observed on CRP (0.867, CRP ≥ 26.85 mg/L). CONCLUSIONS: A three-part differential hematology analyzer has the potential to not only trigger malaria diagnosis confirmation but also assess the severity of the infection when CRP is considered.


Assuntos
Proteína C-Reativa , Malária , Estudos de Casos e Controles , Humanos , Leucócitos , Malária/diagnóstico , Sensibilidade e Especificidade
9.
Clin Chem Lab Med ; 2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-33645170

RESUMO

Starting from the discussion topics triggered by Hoffmann about the past and current basophil counting, a broader view of the role and future of laboratory hematology, passing through some general considerations concerning the idea of laboratory medicine in the healthcare pathway between technology and professionalism, is here provided.

10.
Thromb J ; 19(1): 29, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33947405

RESUMO

INTRODUCTION: Platelet count can be altered in various diseases and treatments and measuring it may provide better insight into the expected outcome. So far, quantification of platelet count is done within laboratory conditions by using established hematology analyzers, whereas a point-of-care device could be used for this purpose outside of the clinical laboratories. AIM: Our aim was to assess the closeness of agreement between a newly developed point-of-care PC100 platelet counter and two reference methods (Sysmex® XP-300, Sysmex® XN-9000) in measuring platelet counts in whole blood and platelet-rich-plasma (PRP). METHOD: Whole blood was obtained from 119 individuals, of which 74 were used to prepare PRP samples. Whole blood platelet count was measured by the two reference methods and the PC100 platelet counter. PRP was prepared from the whole blood and platelet count was adjusted to the range of 250-3600 × 103/µl and measured with the PC100 platelet counter and Sysmex® XP-300. RESULTS: A median difference of - 1.35% and - 2.98% occurred in whole blood platelet count between the PC100 platelet counter and the Sysmex® XP-300 and Sysmex® XN-9000, respectively. A strong linear correlation (r ≥ 0.98) was seen in both cases and regression equations indicated neither a constant nor a proportional bias between the methods. Direct comparison of the two reference methods revealed a median difference of - 1.15% and a strongly linear relationship (r = 0.99). Platelet count in PRP resulted in a median difference of 1.42% between the PC100 platelet counter and the reference method, Sysmex® XP-300. While the difference between two methods increased with concentration of platelets in PRP, a strong linear relationship remained throughout the whole measuring interval indicated by the high correlation coefficient (r = 0.99). Assessment of the predicted bias at predefined platelet counts showed that the bias in platelet counts falls within the acceptance criterion for both whole blood and PRP measurements. CONCLUSIONS: Our results show that the PC100 platelet counter can be used interchangeably with the reference methods for determining platelet counts.

11.
J Clin Lab Anal ; 35(8): e23827, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34117659

RESUMO

BACKGROUND: The automated hematology analyzer Celltac G (Nihon Kohden) was designed to improve leukocyte differential performance. Comparison with analyzers using different leukocyte detection principles and differential leukocyte count on wedge film (Wedge-Diff) shows its clinical utility, and comparison with immunophenotypic leukocyte differential reference method (FCM-Ref) shows its accuracy performance. METHODS: For method comparison, 598 clinical samples and 46 healthy volunteer samples were selected. The two comparative hematology analyzers (CAAs) used were XN-9000 (Sysmex) and CELL-DYN Sapphire (Abbott). The FCM-Ref provided by the Japanese Society for Laboratory Hematology was selected, and a flow cytometer Navios (Beckman-Coulter) was used. In manual differential, two kinds of automated slide makers were used: SP-10 (Sysmex) for wedge technique and SPINNER-2000 (Lion-Power) for spinner technique. The spinner technique avoids the issue of Wedge-Diff smudge cells by removing the risk of breaking cells and non-uniformity of blood cell distribution on films (Spinner-Diff). RESULTS: The Celltac G showed sufficient comparability (r = 0.67-1.00) with the CAAs for each leukocyte differential counting value at 0.00-40.87(109 /L), and sufficient comparability (r = 0.73-0.97) with FCM-Ref for each leukocyte differential percentage at 0.4-78.5. The identification ratio of the FCM-Ref in CD45-positive cells was 99.7% (99.4% to 99.8%). Differences were found between FCM-Ref/Celltac G/XN-9000/Spinner-Diff and Wedge-Diff for monocytes and neutrophils. The appearance ratio of smudge cells on wedge and spinner film was 12.5% and 0.5%. CONCLUSION: The Celltac G hematology analyzer's leukocyte differential showed adequate accuracy compared with the CAAs, FCM-Ref, and two manual methods and was considered suitable for clinical use.


Assuntos
Testes Hematológicos/instrumentação , Testes Hematológicos/métodos , Leucócitos , Antígenos CD , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Humanos , Leucócitos/metabolismo , Monócitos
12.
J Clin Lab Anal ; 35(2): e23638, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33314392

RESUMO

BACKGROUND: Although hematologic review criteria for general hospitals have been established, they may be insufficient for cancer hospitals. This study aimed to establish the appropriate review criteria for hematology analyzers in cancer hospitals. METHODS: A total of 1003 samples from our hospital were randomly selected for blood smear preparation and microscopic review. The review criteria of the International Consensus Group for Hematology Review (ICGH) and Chinese consensus group were used to obtain the review, true-negative (TN), true-positive (TP), false-negative (FN), and false-positive (FP) rates, as well as the triggered rules. Our review criteria were established by comparing flag or numeric value information of TP and FP samples, adjusting rules to obtain better efficiency, a low slide review rate, and an acceptable FN rate. RESULTS: Overall, 197 (19.64%) samples showed positive smear findings. Compared to the ICGH criteria, the slide review rate of the newly established criteria declined from 51.25% to 39.28%, and the TP and TN rates increased from 17.85% and 46.06% to 23.13% and 55.83%, respectively. The FN rate of the newly established criteria was 3.69%. Another set of samples used to validate the newly established criteria yielded the review, FN, and FP rates as 33.49%, 1.86%, and 25.58%, respectively. CONCLUSION: The newly established review criteria for hematology analyzers enabled the prompt identification, smear, and further verification of doubtful specimens, without a significant increase in the workload, thus improving the efficiency of the review process. This study provided data support for other cancer hospitals to establish review criteria.


Assuntos
Institutos de Câncer , Testes Hematológicos/instrumentação , Testes Hematológicos/normas , Laboratórios Hospitalares , Eritrócitos/patologia , Reações Falso-Negativas , Reações Falso-Positivas , Testes Hematológicos/métodos , Humanos , Leucócitos/patologia , Linfócitos/patologia
13.
Clin Chem Lab Med ; 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33554563

RESUMO

Basophils (basophilic granulocytes) are the least abundant cells in blood. Nowadays, basophils are included in the complete blood count performed by hematology analyzers and therefore reported in practically all patients in whom hematologic investigations are requested. However, hematology analyzers are not reliable enough to report clinically useful results. This is due to a combination of very high analytical imprecision and poor specificity, because the chemical and physical methods used for basophil counting in hematology analyzers are ill-defined and thus basophils are not well recognized by the analyzers. As a result, false basophil counts are quite common. In view of increasing analytical performance demands, hematology laboratories should stop reporting basophil counts produced by hematology analyzers. Suggestions for alternative pathways are presented for those situations where basophils are of clinical relevance.

14.
Clin Chem Lab Med ; 58(8): 1282-1290, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32069228

RESUMO

Background The complete blood count (CBC) is a basic test routinely ordered by physicians as a part of initial diagnostic work-up on their patients. To ensure safe clinical application of the CBC, reliable biological variation (BV) data are needed to establish analytical performance specifications. Our aim was to define the BV of CBC parameters using a rigorous protocol that is compliant with the Biological Variation Data Critical Appraisal Checklist (BIVAC) provided by the European Federation of Clinical Chemistry and Laboratory Medicine. Methods Blood samples drawn from 41 healthy Chinese subjects (22 females and 19 males; 23-59 years of age) once monthly for 6 consecutive months were analyzed using an ABX Pentra 80 instrument. The instrument was precisely calibrated. All samples were analyzed in duplicate for 13 CBC parameters. The data were assessed for outliers, normality, and variance homogeneity prior to nested ANOVA. Gender-stratified within-subject (CVI) and between-subject (CVG) BV estimates were calculated. Results The number of remaining data for each subject was 442-484 after removing outliers. No significant differences existed between female/male CVI estimates. Except for leukocytes, neutrophils, and lymphocytes, the mean values of 10 parameters differed significantly between genders, rendering partitioning of CVG data between genders. No significant differences were detected between most BV estimates and recently published estimates representing a Europid population. Conclusions Most BV estimates in BIVAC-compliant studies are similar. The turnover time of blood cells and age distribution of participants should be considered in a CBC BV study. Our study will contribute to global BV estimates and future studies.


Assuntos
Testes Hematológicos/normas , Adulto , China , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
15.
Cell Mol Biol (Noisy-le-grand) ; 66(7): 202-206, 2020 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-33287943

RESUMO

The pandemic diseases caused by SARS-CoV-2 are now threatening human health and survival. Early diagnosis and isolation of mild or asymptomatic COVID-19 patients is important to control the spread of SARS-CoV-2. In this study, we investigate the potential clinical utility of lymphocyte CPD for early diagnosis of COVID-19. To investigate the potential of lymphocyte cell population data (lymphocyte CPD) for use in early diagnosis of coronavirus disease 2019 (COVID-19). Lymphocyte CPD of healthy control (n = 51), common cold patients (n = 49) and mild COVID-19 patients (n = 126) were generated using hematology analyzer. The parameters were subjected to sensitivity and specificity analysis to determine their suitability as biomarkers for early diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Normality analysis showed that lymphocyte CPD followed a normal distribution. There were no significant differences in white blood cells (WBC) and lymphocyte (LY#) counts as well as the neutrophil-to-lymphocyte ratio (NLR) among the groups (p > 0.05). Lymphocyte volume standard deviation (LV-SD), lymphocyte conductivity standard deviation (LC-SD) and lymphocyte light scatter standard deviation (LS-SD) were significantly higher in the COVID-19 group than in common cold and control groups (p < 0.05). The corresponding mean lymphocyte light scattering  (MLS) was significantly reduced in the COVID-19 group, relative to the common cold group, but was significantly increased, when compared with the control group (p < 0.05). Moreover, there was no significant difference in mean lymphocyte volume (MLV) between the COVID-19 group and the common cold or control group (p > 0.05), but it was significantly higher in the common cold group than in the control group (p < 0.05). At a cutoff value ≥ 16.38, LS-SD was more sensitive and specific than other lymphocyte CPD parameters. At a cutoff value ≥ 11.89, LC-SD achieved 84.4 % sensitivity, 87.5 % specificity, and an area under the curve (AUC) of 0.888. However, at a cutoff value ≥ 15.95, LS-SD reached 81.3 % sensitivity, 75 % specificity and an AUC of 0.876. These results suggest that lymphocyte CPD parameters have great diagnostic potential for SARS-CoV-2 infection and can be used for early diagnosis of the disease.


Assuntos
COVID-19/diagnóstico , Contagem de Linfócitos , Adulto , COVID-19/sangue , COVID-19/patologia , Tamanho Celular , Diagnóstico Precoce , Feminino , Humanos , Linfócitos/citologia , Linfócitos/patologia , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
16.
Scand J Clin Lab Invest ; 80(8): 644-648, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32975447

RESUMO

During the evaluation of the DxH 900 hematology analyzer (Beckman Coulter, Miami, FL), we noted that some patient samples produced a false positive white blood cell (WBC) flag, neutrophil blasts (NE-blast), despite the absence of abnormal cells. We investigated whether storage time or anticoagulants such as K2- or K3-ethylenediaminetetraacetic acid (EDTA) would affect complete blood count (CBC) tests on the DxH 900. Sixty-four whole blood samples were collected in K3-EDTA tubes, and 44 were simultaneously drawn in K2-EDTA tubes. Samples were tested at the following two intervals: within 30 min of collection (0 min) and after an additional 30 min of roller-mixing at room temperature (30 min). WBC differential dataplots in 0-min K3-EDTA tubes showed a mixed cell population between lymphocytes and neutrophils in 22 patients presenting the NE-blast flag. All 22 samples revealed normal WBC differential dataplots after 30 min of roller-mixing. The significantly lower mean neutrophil volume in specimens of 0-min K3-EDTA tubes than those of 0-min K2-EDTA, 30-min K2-EDTA and 30-min K3-EDTA tubes appear to be the cause of the false flag. Unlike blood cell counts, mean platelet volume (MPV) was significantly higher at 30 min using both EDTA tubes than that at 0 min. In conclusion, K3-EDTA can produce a false positive flag, NE-blast, on the DxH 900. MPV increases over time irrespective of EDTA salt type.


Assuntos
Anticoagulantes/química , Contagem de Células Sanguíneas/normas , Ácido Edético/química , Doenças Hematológicas/sangue , Hematologia/normas , Contagem de Leucócitos/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação Laboratorial , Plaquetas/patologia , Criança , Reações Falso-Positivas , Feminino , Doenças Hematológicas/diagnóstico , Hematologia/instrumentação , Hematologia/métodos , Humanos , Linfócitos/patologia , Masculino , Volume Plaquetário Médio/métodos , Pessoa de Meia-Idade , Neutrófilos/patologia
17.
J Clin Lab Anal ; 34(9): e23395, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32519385

RESUMO

BACKGROUND: The XPEN60 CRP&SAA (hereafter XPEN60) is a new automated hematology analyzer that can rapidly detect C-reactive protein (CRP), serum amyloid A (SAA), and blood cell counts (CBC), including the 5-part differential of white blood cells (5-DIFF). The aim of this study was to evaluate the analytical performance of XPEN60. METHODS: The analytical performance of XPEN60 was evaluated on the basis of several parameters, including the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), precision, accuracy, carryover, linearity, clinical reportable range (CRR), and interference test. In addition, method comparisons between CBC and 5-DIFF, CRP, and SAA were performed on several systems. RESULTS: Total imprecision and accuracy for all parameters fell within acceptable criteria, and excellent measurements were observed in the dilution linearity (coefficient of determination, R2  > .99). LoBs and LoDs (0 and 0.21 mg/L for CRP, 1.1 and 2.27 mg/L for SAA) satisfy the manufacturer's statement. LoQs were 0.61 and 3.62 mg/L for CRP and SAA, respectively. No significant carryover or interference tests (<10%) were observed in this study. The comparison analysis demonstrated strong agreement between XPEN60 results and those of Sysmex-XN1000 (XN1000), except for basophils (Bas) and eosinophils (Eos). The data correlated well with E601 and Mindray CRP-M100 for CRP. CONCLUSION: XPEN60 was demonstrated satisfactory analytical performance, which made it well-suited for use in clinical laboratories, emergency departments, and community hospitals.


Assuntos
Contagem de Células Sanguíneas , Análise Química do Sangue , Proteína C-Reativa/análise , Proteína Amiloide A Sérica/análise , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/normas , Análise Química do Sangue/instrumentação , Análise Química do Sangue/normas , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
18.
J Stroke Cerebrovasc Dis ; 29(1): 104496, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31732459

RESUMO

BACKGROUND: The utility of light transmission aggregometry (LTA)-based assessment of platelet function in acute ischemic stroke patients remains controversial. This study aimed to clarify why LTA failed to estimate platelet function in acute ischemic stroke patients. METHODS: Using LTA, we evaluated the platelet aggregation abilities of citrated blood samples from 22 acute noncardiogenic ischemic stroke patients prior to treatment and compared them with those of 65 heathy volunteer controls. Platelet counts and mean platelet volumes (MPV) of citrated blood and platelet-rich plasma (PRP) prepared for LTA were evaluated simultaneously. Using a hematology analyzer, we also measured and compared the aggregation-prone properties of platelets in the hematology analysis process between patient and control samples. RESULTS: Although platelets aggregated more easily and frequently in patient samples (P < .01), the maximum aggregation rate (MA%) of LTA was paradoxically lower in patients than in controls (P < .05). The PRP/citrated blood ratio of platelet counts and MPV were significantly lower in patients than in controls (P < .05). CONCLUSIONS: Our results suggest that MA% of LTA is erroneously displayed as lower values than the actual status in patients with increased platelet aggregation ability such as acute ischemic stroke because activated large platelets are preaggregated and thus decreased in the PRP on LTA.


Assuntos
Isquemia Encefálica/diagnóstico , Agregação Plaquetária , Testes de Função Plaquetária , Acidente Vascular Cerebral/diagnóstico , Adulto , Idoso , Isquemia Encefálica/sangue , Isquemia Encefálica/terapia , Estudos de Casos e Controles , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/terapia
19.
Rev Invest Clin ; 72(1): 37-45, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132736

RESUMO

BACKGROUND: The hematology analyzer, Sysmex XN-1000, generates white blood cell count with varying scattering intensities during a complete blood count (CBC) analysis. OBJECTIVES: The objectives of the study were to study the predictive role of median and coefficient of variation of neutrophil scattering items in blood samples for differentiation of leukemic subjects. METHODS: We evaluated six neutrophil scattering parameters: neutrophil side scatter mean intensity, neutrophil side fluorescence light (SFL) mean intensity, neutrophil forward scatter mean intensity, neutrophil side scatter area distribution width (NE-WX), neutrophil SFL area distribution width (NE-WY), and neutrophil forward scatter area distribution width (NE-WZ), measured in white blood cell differential scattergram generated by the hematology analyzer (Sysmex XN-1000) at an academic medical center. RESULTS: We collected 433 blood samples from acute myeloid leukemia (AML) and acute lymphoid leukemia (ALL) cases and normal controls. AML group showed highly significant differences in the mean values compared with the control group. Out of six neutrophil scattering items, NE-WX, NE-WY, and NE-WZ showed high efficiency, with area under the curve (AUC) values of 0.764, 0.748, and 0.757, respectively, to differentiate AML from ALL cases and control groups. When comparing combined acute leukemia cases (AML plus ALL) with the control group, NE-WX, NE-WY, and NE-WZ generated highly significant AUC values (0.840, 0.884, and 0.801, respectively). CONCLUSION: The neutrophil scattering parameters generated during CBC analysis provide a new tool for the prediction of acute leukemia and its lineage.


Assuntos
Contagem de Células Sanguíneas/métodos , Leucemia Mieloide Aguda/sangue , Neutrófilos/metabolismo , Leucemia-Linfoma Linfoblástico de Células Precursoras/sangue , Adolescente , Adulto , Contagem de Células Sanguíneas/instrumentação , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
Rinsho Ketsueki ; 61(5): 564-569, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-32507825

RESUMO

Morphological analysis of the blood smear is an essential element of diagnosing a disease hematologically and has been performed by conventional manual light microscopy for several decades. Although this method is the gold standard, it is labor-intensive, requires continuous training of the personnel, and is subject to relatively large interobserver variability. The artificial intelligence (AI)-based automated methods for the digital morphological analysis of blood smears have recently been developed. In this review, our recently developed convolutional neural network (CNN)-based digital morphology hematology analysis system is introduced. AI-based digital morphology hematology analysis system is firstly needed to incorporate digital imaging of blood cells into the analysis system. It is essential to establish a digital platform, which was already established in the radiological diagnosis, for the dissemination of CNN-based automated digital morphology hematology analyzer in the near future.


Assuntos
Inteligência Artificial , Doenças Hematológicas , Testes Hematológicos , Humanos , Microscopia , Redes Neurais de Computação