Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Skeletal Radiol ; 53(10): 2051-2065, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38194095

RESUMO

Clinical manifestations of dermatological and musculoskeletal conditions can sometimes overlap, leading to confusion in diagnosis. Patients with nail and skin infections may undergo imaging examinations with suspicions of muscle, tendon, or joint injuries. Dermatological infections often involve soft tissues and musculoskeletal structures, and their etiology can range from fungi, bacteria, viruses, to protozoa. Relying solely on physical examination may not be sufficient for accurate diagnosis and treatment planning, necessitating the use of complementary imaging exams. The objective of this paper is to present and discuss imaging findings of the main infectious conditions affecting the nail apparatus and skin. The paper also highlights the importance of imaging in clarifying diagnostic uncertainties and guiding appropriate treatment for dermatological conditions.


Assuntos
Doenças da Unha , Humanos , Doenças da Unha/diagnóstico por imagem , Diagnóstico Diferencial , Dermatopatias Infecciosas/diagnóstico por imagem , Diagnóstico por Imagem/métodos
2.
Angew Chem Int Ed Engl ; 63(10): e202318948, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38212253

RESUMO

Ultra-high field (UHF) magnetic resonance imaging (MRI) has emerged as a focal point of interest in the field of cancer diagnosis. Despite the ability of current paramagnetic or superparamagnetic smart MRI contrast agents to selectively enhance tumor signals in low-field MRI, their effectiveness at UHF remains inadequate due to inherent magnetism. Here, we report a ligand-mediated magnetism-conversion nanoprobe (MCNP) composed of 3-mercaptopropionic acid ligand-coated silver-gadolinium bimetallic nanoparticles. The MCNP exhibits a pH-dependent magnetism conversion from ferromagnetism to diamagnetism, facilitating tunable nanomagnetism for pH-activatable UHF MRI. Under neutral pH, the thiolate (-S- ) ligands lead to short τ'm and increased magnetization of the MCNPs. Conversely, in the acidic tumor microenvironment, the thiolate ligands are protonated and transform into thiol (-SH) ligands, resulting in prolonged τ'm and decreased magnetization of the MCNP, thereby enhancing longitudinal relaxivity (r1) values at UHF MRI. Notably, under a 9 T MRI field, the pH-sensitive changes in Ag-S binding affinity of the MCNP lead to a remarkable (>10-fold) r1 increase in an acidic medium (pH 5.0). In vivo studies demonstrate the capability of MCNPs to amplify MRI signal of hepatic tumors, suggesting their potential as a next-generation UHF-tailored smart MRI contrast agent.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias , Humanos , Ligantes , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Concentração de Íons de Hidrogênio , Microambiente Tumoral
3.
J Nanobiotechnology ; 21(1): 434, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980476

RESUMO

Manganese-based nanomaterials (Mn-nanomaterials) hold immense potential in cancer diagnosis and therapies. However, most Mn-nanomaterials are limited by the low sensitivity and low efficiency toward mild weak acidity (pH 6.4-6.8) of the tumor microenvironment, resulting in unsatisfactory therapeutic effect and poor magnetic resonance imaging (MRI) performance. This study introduces pH-ultrasensitive PtMn nanoparticles as a novel platform for enhanced ferroptosis-based cancer theranostics. The PtMn nanoparticles were synthesized with different diameters from 5.3 to 2.7 nm with size-dominant catalytic activity and magnetic relaxation, and modified with an acidity-responsive polymer to create pH-sensitive agents. Importantly, R-PtMn-1 (3 nm core) presents "turn-on" oxidase-like activity, affording a significant enhancement ratio (pH 6.0/pH 7.4) in catalytic activity (6.7 folds), compared with R-PtMn-2 (4.2 nm core, 3.7 folds) or R-PtMn-3 (5.3 nm core, 2.1 folds), respectively. Moreover, R-PtMn-1 exhibits dual-mode contrast in high-field MRI. R-PtMn-1 possesses a good enhancement ratio (pH 6.4/pH 7.4) that is 3 or 3.2 folds for T1- or T2-MRI, respectively, which is higher than that of R-PtMn-2 (1.4 or 1.5 folds) or R-PtMn-3 (1.1 or 1.2 folds). Moreover, their pH-ultrasensitivity enabled activation specifically within the tumor microenvironment, avoiding off-target toxicity in normal tissues during delivery. In vitro studies demonstrated elevated intracellular reactive oxygen species production, lipid peroxidation, mitochondrial membrane potential changes, malondialdehyde content, and glutathione depletion, leading to enhanced ferroptosis in cancer cells. Meanwhile, normal cells remained unaffected by the nanoparticles. Overall, the pH-ultrasensitive PtMn nanoparticles offer a promising strategy for accurate cancer diagnosis and ferroptosis-based therapy.


Assuntos
Nanopartículas , Neoplasias , Humanos , Manganês/química , Medicina de Precisão , Meios de Contraste/química , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Imageamento por Ressonância Magnética/métodos , Nanopartículas/química , Linhagem Celular Tumoral , Microambiente Tumoral
4.
J Integr Neurosci ; 22(6): 142, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-38176928

RESUMO

The Center for Disease Control and Prevention reports that traumatic brain injury (TBI) was related to over 64,000 deaths in the United States in 2020, equating to more than 611 TBI-related hospitalizations and 176 TBI-related deaths per day. There are both long- and short-term sequelae involved with the pathophysiology of TBI that can range from mild to severe. Recently, more effort has been devoted to understanding the long-term consequences of TBI and how early detection of these injuries can prevent late clinical manifestations. Obtaining proper, detailed imaging is key to guiding the direction of intervention, but there is a gap in the understanding of how TBI imaging can be used to predict and prevent the long-term morbidities seen with even mild forms of TBI. There have been significant strides in the advancement of TBI imaging that allows for quicker, more affordable, and more effective imaging of intracranial bleeds, axonal injury, tissue damage, and more. Despite this, there is still room for improved standardization and more data supporting the justification of using certain imaging modalities. This review aims to outline recent advancements in TBI imaging and areas that require further investigation to improve patient outcomes and minimize the acute and chronic comorbidities associated with TBI.


Assuntos
Lesões Encefálicas Traumáticas , Lesões Encefálicas , Humanos , Estados Unidos , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Neuroimagem/métodos , Encéfalo/diagnóstico por imagem
5.
J Magn Reson Imaging ; 56(2): 354-365, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34921571

RESUMO

BACKGROUND: Ultra-high field magnetic resonance imaging (MRI) has obvious advantages in acquiring high-resolution images. 7 T MRI has been clinically approved and 21.1 T MRI has also been tested on rodents. PURPOSE: To examine the effects of ultra-high field on mice behavior and neuron activity. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: Ninety-eight healthy C57BL/6 mice and 18 depression model mice. FIELD STRENGTH: 11.1-33.0 T SMF (static magnetic field) for 1 hour and 7 T for 8 hours. Gradients were not on and no imaging sequence was used. ASSESSMENT: Open field test, elevated plus maze, three-chambered social test, Morris water maze, tail suspension test, sucrose preference test, blood routine, biochemistry examinations, enzyme-linked immunosorbent assay, immunofluorescent assay. STATISTICAL TESTS: The normality of the data was assessed by Shapiro-Wilk test, followed by Student's t test or the Mann-Whitney U test for statistical significance. The statistical cut-off line is P < 0.05. RESULTS: Compared to the sham group, healthy C57/6 mice spent more time in the center area (35.12 ± 4.034, increased by 47.19%) in open field test and improved novel index (0.6201 ± 0.02522, increased by 16.76%) in three-chambered social test a few weeks after 1 hour 11.1-33.0 T SMF exposure. 7 T SMF exposure for 8 hours alleviated the depression state of depression mice, including less immobile time in tail suspension test (58.32% reduction) and higher sucrose preference (increased by 8.80%). Brain tissue analysis shows that 11.1-33.0 T and 7 T SMFs can increase oxytocin by 164.65% and 36.03%, respectively. Moreover, the c-Fos level in hippocampus region was increased by 14.79%. DATA CONCLUSION: 11.1-33.0 T SMFs exposure for 1 hour or 7 T SMF exposure for 8 hours did not have detrimental effects on healthy or depressed mice. Instead, these ultra-high field SMFs have anti-depressive potentials. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Animais , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Estudos Prospectivos , Sacarose
6.
Ultrasound Obstet Gynecol ; 60(1): 109-117, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34826157

RESUMO

OBJECTIVE: Although fetal autopsy is generally recommended to confirm or refute the antemortem diagnosis, parental acceptance of the procedure has fallen over time, mainly due to its invasiveness. Contrast-enhanced microfocus CT (micro-CT) and high-field magnetic resonance imaging (HF-MRI, ≥ 3 Tesla) have both been suggested as non-invasive alternatives to conventional fetal autopsy for fetuses < 20 weeks of gestation. The aim of this study was to compare these two modalities in postmortem whole-body fetal imaging. METHODS: In this study, the imaging process and quality of micro-CT and HF-MRI were compared using both qualitative and quantitative assessments. For the qualitative evaluation, fetal anatomy experts scored 56 HF-MRI and 56 micro-CT images of four human fetuses aged 13-18 gestational weeks on two components: overall image quality and the ability to recognize and assess 21 anatomical structures. For the quantitative evaluation, participants segmented manually three organs with increasing complexity to assess interobserver variability. In addition, the signal-to-noise and contrast-to-noise ratios of five major organs were determined. RESULTS: Both imaging techniques were able to reach submillimeter voxel size. The highest resolution of micro-CT was 22 µm (isotropic), while the highest resolution of HF-MRI was 137 µm (isotropic). The qualitative image assessment form was sent to 45 fetal anatomy experts, of whom 36 (80%) responded. It was observed that micro-CT scored higher on all components of the qualitative assessment compared with HF-MRI. In addition, the quantitative assessment showed that micro-CT had lower interobserver variability and higher signal-to-noise and contrast-to-noise ratios. CONCLUSIONS: Our findings show that micro-CT outperforms HF-MRI in postmortem whole-body fetal imaging in terms of both quantitative and qualitative outcomes. Combined, these findings suggest that the ability to extract diagnostic information is greater when assessing micro-CT compared with HF-MRI images. We, therefore, believe that micro-CT is the preferred imaging modality as an alternative to conventional fetal autopsy for early gestation and is an indispensable tool in postmortem imaging services. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Feto , Imageamento por Ressonância Magnética , Autopsia/métodos , Feminino , Feto/diagnóstico por imagem , Feto/patologia , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética/métodos , Gravidez , Microtomografia por Raio-X/métodos
7.
Sensors (Basel) ; 22(11)2022 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35684895

RESUMO

The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T-400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B1|-, |B1+|-, |B1-|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B1-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B1-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Simulação por Computador , Campos Eletromagnéticos , Imageamento por Ressonância Magnética/métodos , Camundongos , Imagens de Fantasmas
8.
Neuroimage ; 235: 118010, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-33819610

RESUMO

BACKGROUND: The emerging field of ultra-high field MRI (UHF-MRI, 7 Tesla and higher) provides the opportunity to image human brains at a higher resolution and with higher signal-to-noise ratios compared to the more widely available 1.5 and 3T scanners. Scanning postmortem tissue additionally allows for greatly increased scan times and fewer movement issues leading to improvements in image quality. However, typical postmortem neuroimaging routines involve placing the tissue within plastic bags that leave room for susceptibility artifacts from tissue-air interfaces, inadequate submersion, and leakage issues. To address these challenges in postmortem imaging, a custom-built nonferromagnetic container was developed that allows whole brain hemispheres to be scanned at sub-millimeter resolution within typical head-coils. METHOD: The custom-built polymethylmethacrylaat container consists of a cylinder with a hemispheric side and a lid with valves on the adjacent side. This shape fits within common MR head-coils and allows whole hemispheres to be submerged and vacuum sealed within it reducing imaging artifacts that would otherwise arise at air-tissue boundaries. Two hemisphere samples were scanned on a Siemens 9.4T Magnetom MRI scanner. High resolution T2* weighted data was obtained with a custom 3D gradient echo (GRE) sequence and diffusion-weighted imaging (DWI) scans were obtained with a 3D kT-dSTEAM sequence along 48 directions. RESULTS: The custom-built container proved to submerge and contain tissue samples effectively and showed no interferences with MR scanning acquisition. The 3D GRE sequence provided high resolution isotropic T2* weighted data at 250 µm which showed a clear visualization of gray and white matter structures. DWI scans allowed for dense reconstruction of structural white matter connections via tractography. CONCLUSION: Using this custom-built container worked towards achieving high quality MR images of postmortem brain material. This procedure can have advantages over traditional schemes including utilization of a standardized protocol and the reduced likelihood of leakage. This methodology could be adjusted and used to improve typical postmortem imaging routines.


Assuntos
Autopsia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Artefatos , Autopsia/instrumentação , Encéfalo/fisiopatologia , Encefalopatias/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Razão Sinal-Ruído
9.
Magn Reson Med ; 85(2): 1013-1027, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32789980

RESUMO

PURPOSE: To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS: A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on the image quality was performed. Intrinsic signal-to-noise-ratio maps were determined using a pseudo-multiple replica approach. Measurements with different echo times were compared and processed to one multiecho data image combination image. Based on the multiecho acquisitions, T2 *-relaxation time maps were calculated. Algorithmic spinal cord detection and gray matter/white matter segmentation were tested. RESULTS: An echo time between 9 and 13.8 ms compromised best between gray matter/white matter contrast and image quality. A maximum in-plane resolution of 0.15 × 0.15 mm2 was achieved for anatomical images. These images offered excellent image quality and made small structures of the spinal cord visible. The scanner vendor implemented B0 shimming routine performed best during this work. Intrinsic signal-to-noise-ratio values of between 6600 and 8060 at the upper cervical spinal cord were achieved. Detection and segmentation worked reliably. An average T2 *-time of 24.88 ms ± 6.68 ms for gray matter and 19.37 ms ± 8.66 ms for white matter was calculated. CONCLUSION: The proposed human brain coil can be used to image the spinal cord. The maximum in-plane resolution in this work was higher compared with the 7T results from the literature. The 9.4T acquisitions made the small structures of the spinal cord clearly visible.


Assuntos
Imageamento por Ressonância Magnética , Substância Branca , Encéfalo/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Medula Espinal/diagnóstico por imagem , Substância Branca/diagnóstico por imagem
10.
Mult Scler ; 26(8): 987-992, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-30730233

RESUMO

BACKGROUND: Investigating the degeneration of specific thalamic nuclei in multiple sclerosis (MS) remains challenging. METHODS: White-matter-nulled (WMn) MPRAGE, MP-FLAIR, and standard T1-weighted magnetic resonance imaging (MRI) were performed on MS patients (n = 15) and matched controls (n = 12). Thalamic lesions were counted in individual sequences and lesion contrast-to-noise ratio (CNR) was measured. Volumes of 12 thalamic nuclei were measured using an automatic segmentation pipeline specifically developed for WMn-MPRAGE. RESULTS: WMn-MPRAGE showed more thalamic MS lesions (n = 35 in 9 out of 15 patients) than MP-FLAIR (n = 25) and standard T1 (n = 23), which was associated with significant improvement of CNR (p < 0.0001). MS patients had whole thalamus atrophy (p = 0.003) with lower volumes found for the anteroventral (p < 0.001), the pulvinar (p < 0.0001), and the habenular (p = 0.004) nuclei. CONCLUSION: WMn-MPRAGE and automatic thalamic segmentation can highlight thalamic MS lesions and measure patterns of focal thalamic atrophy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Núcleos Talâmicos/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto , Atlas como Assunto , Atrofia/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Núcleos Talâmicos/patologia , Substância Branca/patologia
11.
J Magn Reson Imaging ; 50(3): 868-877, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30663150

RESUMO

BACKGROUND: Although radiation therapy (RT) contributes to survival benefit in many brain tumor patients, it has also been associated with long-term brain injury. Cerebral microbleeds (CMBs) represent an important manifestation of radiation-related injury. PURPOSE: To characterize the change in size and number of CMBs over time and to evaluate their relationship to white matter structural integrity as measured using diffusion MRI indices. STUDY TYPE: Longitudinal, retrospective, human cohort. POPULATION: In all, 113 brain tumor patients including patients treated with focal RT (n = 91, 80.5%) and a subset of nonirradiated controls (n = 22, 19.5%). FIELD STRENGTH/SEQUENCE: Single and multiecho susceptibility-weighted imaging (SWI) and multiband, shell, and direction diffusion tensor imaging (DTI) at 7 T. ASSESSMENT: Patients were scanned either once or serially. CMBs were detected and quantified on SWI images using a semiautomated approach. Local and global fractional anisotropy (FA) were measured from DTI data for a subset of 35 patients. STATISTICAL TESTS: Potential risk factors for CMB development were determined by multivariate linear regression and using linear mixed-effect models. Longitudinal FA was quantitatively and qualitatively evaluated for trends. RESULTS: All patients scanned at 1 or more years post-RT had CMBs. A history of multiple surgical resections was a risk factor for development of CMBs. The total number and volume of CMBs increased by 18% and 11% per year, respectively, although individual CMBs decreased in volume over time. Simultaneous to these microvascular changes, FA decreased by a median of 6.5% per year. While the majority of nonirradiated controls had no CMBs, four control patients presented with fewer than five CMBs. DATA CONCLUSION: Identifying patients who are at the greatest risk for CMB development, with its likely associated long-term cognitive impairment, is an important step towards developing and piloting preventative and/or rehabilitative measures for patients undergoing RT. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2019;50:868-877.


Assuntos
Neoplasias Encefálicas/radioterapia , Hemorragia Cerebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Lesões por Radiação/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substância Branca/patologia
12.
Neuroimage ; 133: 288-293, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26994830

RESUMO

PURPOSE: To examine the extent of genetic damage, assessed from deoxyribonucleic acid (DNA) double-strand breaks (DSBs) and micronuclei (MN) in peripheral blood mononuclear cells obtained from individuals repeatedly exposed to 7T Magnetic Resonance Imaging (MRI). MATERIALS AND METHODS: The study protocol was approved by the local ethics committee. Informed consent was obtained from 22 healthy, non-smoking, non-alcoholic male individuals, who had never undergone radio-/chemo-therapy, scintigraphy, and had not undergone X-ray examination one year prior blood withdrawal. Eleven participants were repeatedly exposed to 7T and 3T MRI while working with/around scanners or frequently participating as 7T and lower field MRI research subjects (mean age 34±7years). The other half was never exposed to 7T or lower field MRI and served as controls (mean age 33±9years). The damage in lymphocytes was assessed using anti-γH2AX immunofluorescence staining of DNA DSBs and by quantification of MN. Isolated cells were further exposed in vitro to 7T MRI either alone or in the presence of the DNA damaging drug etoposide, to determine if there is any additional combined effect. The kinetics of DNA damage repair were examined. RESULTS: The mean base-level of γH2AX foci/cell and incidence of MN between repeatedly exposed and control group were not significantly different (P=0.618 and P=0.535, respectively). The additional in vitro exposure of cells to 7T MRI had no significant impact on MN frequencies and γH2AX foci at 1, 20 and 72h after exposure. CONCLUSION: Frequently repeated 7T MRI exposure did not result in a detectable increase in genotoxicity indices and alterations of DNA repair kinetics.


Assuntos
DNA/efeitos da radiação , Linfócitos/efeitos da radiação , Imageamento por Ressonância Magnética/efeitos adversos , Micronúcleos com Defeito Cromossômico/efeitos da radiação , Irradiação Corporal Total/efeitos adversos , Adulto , Células Cultivadas , DNA/genética , Dano ao DNA , Relação Dose-Resposta à Radiação , Humanos , Linfócitos/patologia , Testes para Micronúcleos , Doses de Radiação , Irradiação Corporal Total/métodos
13.
Hum Brain Mapp ; 37(10): 3486-501, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27160707

RESUMO

Absolute pitch (AP) is known as the ability to recognize and label the pitch chroma of a given tone without external reference. Known brain structures and functions related to AP are mainly of macroscopic aspects. To shed light on the underlying neural mechanism of AP, we investigated the intracortical myeloarchitecture in musicians with and without AP using the quantitative mapping of the longitudinal relaxation rates with ultra-high-field magnetic resonance imaging at 7 T. We found greater intracortical myelination for AP musicians in the anterior region of the supratemporal plane, particularly the medial region of the right planum polare (PP). In the same region of the right PP, we also found a positive correlation with a behavioral index of AP performance. In addition, we found a positive correlation with a frequency discrimination threshold in the anterolateral Heschl's gyrus in the right hemisphere, demonstrating distinctive neural processes of absolute recognition and relative discrimination of pitch. Regarding possible effects of local myelination in the cortex and the known importance of the anterior superior temporal gyrus/sulcus for the identification of auditory objects, we argue that pitch chroma may be processed as an identifiable object property in AP musicians. Hum Brain Mapp 37:3486-3501, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Encéfalo/diagnóstico por imagem , Discriminação da Altura Tonal , Adulto , Povo Asiático , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Música , Bainha de Mielina , Prática Psicológica , Competência Profissional , Testes Psicológicos , Substância Branca/diagnóstico por imagem , População Branca
14.
MAGMA ; 29(3): 379-87, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26861049

RESUMO

OBJECTIVE: To retrospectively assess perception of safety of healthy individuals working with human 7 Tesla (T) magnetic resonance imaging (MRI) scanners. MATERIALS AND METHODS: A total of 66 healthy individuals with a mean age of 31 ± 7 years participated in this retrospective multicentre survey study. Nonparametric correlation analysis was conducted to evaluate the relation between self-reported perception of safety and prevalence of sensory effects while working with 7 T MRI scanners for an average 47 months. RESULTS: The results indicated that 98.5 % of the study participants had a neutral or positive feeling about safety aspects at 7 T MRI scanners. 45.5 % reported that they feel very safe and none of the participants stated that they feel moderately or very unsafe while working with 7 T MRI scanners. Perception of safety was not affected by the number of hours per week spent in the vicinity of the 7 T MRI scanner or the duration of experience with 7 T MRI. More than 50 % of individuals experienced vertigo and metallic taste while working with 7 T MRI scanners. However, participants' perceptions of safety were not affected by the prevalence of MR-related symptoms. CONCLUSIONS: The overall data indicated an average perception of a moderately safe work environment. To our knowledge, this study delineates the first attempt to assess the subjective safety perception among 7 T MRI workers and suggests further investigations are indicated.


Assuntos
Imageamento por Ressonância Magnética , Saúde Ocupacional , Adulto , Campos Eletromagnéticos , Feminino , Voluntários Saudáveis , Humanos , Internet , Masculino , Exposição Ocupacional , Estudos Retrospectivos , Inquéritos e Questionários , Adulto Jovem
15.
Clin Neuroradiol ; 34(1): 45-49, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37000197

RESUMO

PURPOSE: Differentiating normal anatomical variants such as an infundibulum or a vascular loop from true intracranial aneurysms is crucial for patient management. We hypothesize that high-resolution 7 T magnetic resonance imaging (MRI) improves the detection and characterization of normal anatomical variants that may otherwise be misdiagnosed as small unruptured aneurysms. METHODS: This is a retrospective, single-center study. All patients were scanned on a clinically approved 7 T MRI scanner and on a 3 T scanner. Image analysis was performed independently by three neuroradiologists blinded to clinical information. The presence of an unruptured intracranial aneurysm (UIA) and level of diagnostic certainty were assessed and the interrater agreement was calculated. If an aneurysm was present, the anatomic location and shape were recorded and compared. RESULTS: In total, 53 patients with equivocal cerebrovascular findings on 1.5 T or 3 T MRI referred for a 7T MRI examination were included. Aneurysms were suspected in 42 patients examined at 3 T and in 23 patients at 7 T (rate difference 36%, 95% confidence interval, CI, 19-53%, p-value < 0.001). Major disagreement between the field strengths was observed in the A1 segment of anterior cerebral artery/anterior communicating artery (A1/ACOM) complex. The interrater agreement among the readers on the presence of an aneurysm on 7 T MRI was higher than that for 3 T MRI (0.925, 95% CI 0.866-0.983 vs. 0.786, 95% CI 0.700-0.873). CONCLUSION: Our analysis demonstrates a significantly higher interrater agreement and improved diagnostic certainty when small intracranial aneurysms are visualized on 7 T MRI compared to 3 T. In a selected patient cohort, clinical implementation of 7 T MRI may help to establish the definitive diagnosis and thus have a beneficial impact on patient management.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Artéria Cerebral Anterior/patologia , Processamento de Imagem Assistida por Computador
16.
Magn Reson Med Sci ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38346767

RESUMO

PURPOSE: The purpose of this study was to do a feasibility study on a microstrip transmission line (MS) RF coil for a positron emission tomography (PET) insert in a 7 Tesla human MRI system. The proposed MS coil integrated the RF shield of the PET detector as the ground conductor of the coil. We called the integrated module "MS PET coil." METHODS: A single-channel MS PET coil was developed with an integrated RF-shielded PET detector module. For comparison, we also studied a conventional MS coil with a single-layer ground conductor. A lutetium fine silicate (LFS) scintillation crystal block (14 × 14 × 4-layer) with a silicon photomultiplier (Hamamatsu Photonics K.K., Shizuoka, Japan) and a front-end readout circuit board were mounted inside the shield cage of the MS PET coil. The MS PET coil was studied with and without PET detectors. All three coil configurations were studied with a homogeneous phantom in a 7T MRI system (Siemens Healthineers, Erlangen, Germany). PET data measurements were conducted using a Cesium-137 radiation point source. RESULTS: The MR images were similar for the MS coil and the empty MS PET coil, as well as for the cases of MS PET coil with and without PET measurements. Compared to the empty MS PET coil (without PET detector and cable RF shield), decreases in SNR, increases in image noise and RF power, and a slight decrease in resonance frequency were seen for the case of the MS PET coil with the detector and cable shield. Differences in the PET energy histograms or in the crystal identification maps with and without MRI measurements were negligible. CONCLUSIONS: Both the MRI and PET performances of the MS PET coil showed responses that matched the MS coil responses. The performance variations of MRI data with and without PET measurement and PET data with and without MR imaging were negligible.

17.
Front Neurosci ; 17: 1236876, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37869518

RESUMO

Corpora amylacea (CA) are polyglucosan aggregated granules that accumulate in the human body throughout aging. In the cerebrum, CA have been found in proximity to ventricular walls, pial surfaces, and blood vessels. However, studies showing their three-dimensional spatial distribution are sparse. In this study, volumetric images of four human brain stems were obtained with MRI and phase-contrast X-ray microtomography, followed up by Periodic acid Schiff stain for validation. CA appeared as hyperintense spheroid structures with diameters up to 30 µm. An automatic pipeline was developed to segment the CA, and the spatial distribution of over 200,000 individual corpora amylacea could be investigated. A threefold-or higher-density of CA was detected in the dorsomedial column of the periaqueductal gray (860-4,200 CA count/mm3) than in the superior colliculus (150-340 CA count/mm3). We estimated that about 2% of the CA were located in the immediate vicinity of the vessels or in the peri-vascular space. While CA in the ependymal lining of the cerebral aqueduct was rare, the sub-pial tissue of the anterior and posterior midbrain contained several CA. In the sample with the highest CA density, quantitative maps obtained with MRI revealed high R2* values and a diamagnetic shift in a region which spatially coincided with the CA dense region.

18.
Ther Adv Neurol Disord ; 16: 17562864221143834, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36846471

RESUMO

Background: Due to the absence of robust biomarkers, and the low sensitivity and specificity of routine imaging techniques, the differential diagnosis between Parkinson's disease (PD) and multiple system atrophy (MSA) is challenging. High-field magnetic resonance imaging (MRI) opened up new possibilities regarding the analysis of pathological alterations associated with neurodegenerative processes. Recently, we have shown that quantitative susceptibility mapping (QSM) enables visualization and quantification of two major histopathologic hallmarks observed in MSA: reduced myelin density and iron accumulation in the basal ganglia of a transgenic murine model of MSA. It is therefore emerging as a promising imaging modality on the differential diagnosis of Parkinsonian syndromes. Objectives: To assess QSM on high-field MRI for the differential diagnosis of PD and MSA. Methods: We assessed 23 patients (nine PDs and 14 MSAs) and nine controls using QSM on 3T and 7T MRI scanners at two academic centers. Results: We observed increased susceptibility in MSA at 3T in prototypical subcortical and brainstem regions. Susceptibility measures of putamen, pallidum, and substantia nigra reached excellent diagnostic accuracy to separate both synucleinopathies. Increase toward 100% sensitivity and specificity was achieved using 7T MRI in a subset of patients. Magnetic susceptibility correlated with age in all groups, but not with disease duration in MSA. Sensitivity and specificity were particularly high for possible MSA, and reached 100% in the putamen. Conclusion: Putaminal susceptibility measures, in particular on ultra-high-field MRI, may distinguish MSA patients from both, PD and controls, allowing an early and sensitive diagnosis of MSA.

19.
Plant Biol (Stuttg) ; 25(5): 696-702, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37199025

RESUMO

Water uptake is the fundamental and essential requirement for seed germination. Pecan seed has a hard woody endocarp that plays an important role during water uptake. To explore water uptake during germination, the spatiotemporal pattern of water and effect of the endocarp were analysed using high-field MRI, dye-tracing, wax blocking and SEM of water uptake. Isolated seeds completed water uptake in 8 h while whole seeds required 6 days, hence, cracking the endocarp plays an important role. The hilum is the channel through which water enters the seed, while the remainder of the seed coat consist of cells covered with a waxy layer that act as a barrier to water absorption. The region with the highest water content in pecan seed is the edge of the U-shaped region, and water can progressively diffuse from this U-shaped region into the whole kernel. We report a new water absorption stage between phase II and phase III of the triphasic model of water uptake of pecan seeds. Cracking the endocarp changed water distribution in pecan seeds, which may trigger further water absorption and radicle elongation.


Assuntos
Carya , Água , Sementes , Germinação , Transporte Biológico
20.
Methods Mol Biol ; 2622: 103-119, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36781754

RESUMO

Liposome-mediated anticancer drug delivery has the advantage of limiting the massive cytotoxicity of chemotherapeutic agents. Doxorubicin (DOX) PEG-liposomal does however have a slow-release rate that hinders its therapeutic efficacy. In this study, an integrated therapeutic system based on magnetic thermosensitive liposomes was designed. The chelated gadolinium acquired magnetic properties in the liposomes. The hyperthermia induced by ultra-high-field magnetic resonance imaging (UHF-MRI) enhances the chemotherapeutic effects of DOX. The DOX release from liposomes was facilitated over a narrow range of temperatures owing to the phase transition temperature of the liposomes. The magnetic properties of the liposomes were evident by the elevation of contrast after the exposure to UHF-MRI. Moreover, triple-negative breast cancer (TNBC) cells showed a significant decrease in cellular viability reaching less than 40% viability after 1 h of exposure to UHF-MRI. The liposomes demonstrated a physiological coagulation time and a minimal hemolytic potential in hemocompatibility studies; therefore, they were considered safe for physiological application. As a result, magnetic-thermosensitive liposomal guidance of local delivery of DOX could increase the therapeutic index, thereby reducing the amount of the drug required for systemic administration and the chance of affecting the adjacent tissues.


Assuntos
Antineoplásicos , Lipossomos , Linhagem Celular Tumoral , Doxorrubicina/farmacologia , Doxorrubicina/uso terapêutico , Antineoplásicos/farmacologia , Sistemas de Liberação de Medicamentos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA