Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Skeletal Radiol ; 53(11): 2511-2517, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38236295

RESUMO

Metallosis is an unusual but consequential complication arising from orthopedic hardware implantation, characterized by the deposition of metallic particles in the periprosthetic soft tissues. The incidence of metallosis associated with shoulder arthroplasties is exceptionally rare since the shoulder is not a weight-bearing joint, making it less susceptible to mechanical wear and, consequently, to conditions like particle disease and metallosis. Nevertheless, anomalous metal-on-metal interactions can develop in total shoulder arthroplasties if the polyethylene component fails due to wear, fracture, or dissociation. If left unaddressed, metallosis can incite an adverse immune-mediated local tissue response, culminating in joint destruction and adjacent soft tissues and muscle necrosis. In this case report, the diagnosis of metallosis was made in a patient with an anatomic total shoulder arthroplasty using a state-of-the-art photon counting detector CT supplemented by post-processing metal artifact reduction algorithms. This advanced imaging approach was effective in discerning the source of implant failure and in identifying manifestations of severe metallosis including osteolysis and pseudotumor formation. Advanced imaging methods can accurately characterize the severity and extent of metallosis, thereby helping guide surgical planning to mitigate serious complications associated with this condition.


Assuntos
Artroplastia do Ombro , Falha de Prótese , Humanos , Artroplastia do Ombro/efeitos adversos , Prótese de Ombro/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Metais/efeitos adversos , Masculino , Idoso , Feminino , Reoperação
2.
J Arthroplasty ; 39(9): 2368-2376, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38640966

RESUMO

BACKGROUND: Modular dual mobility (DM) bearings have a junction between a cobalt chrome alloy (CoCrMo) liner and titanium shell, and the risk of tribocorrosion at this interface remains a concern. The purpose of this study was to determine whether liner malseating and liner designs are associated with taper tribocorrosion. METHODS: We evaluated 28 retrieved modular DM implants with a mean in situ duration of 14.6 months (range, 1 to 83). There were 2 manufacturers included (12 and 16 liners, respectively). Liners were considered malseated if a distinct divergence between the liner and shell was present on postoperative radiographs. Tribocorrosion was analyzed qualitatively with the modified Goldberg Score and quantitatively with an optical coordinate-measuring machine. An acetabular shell per manufacturer was sectioned for metallographic analysis. RESULTS: There were 6 implants (22%) that had severe grade 4 corrosion, 6 (22%) had moderate grade 3, 11 (41%) had mild grade 2, and 5 (18.5%) had grade 1 or no visible corrosion. The average volumetric material loss at the taper was 0.086 ± 0.19 mm3. There were 7 liners (25%) that had radiographic evidence of malseating, and all were of a single design (P = .01). The 2 liner designs were fundamentally different from one another with respect to the cobalt chrome alloy type, taper surface finish, and shape deviations. Malseating was an independent risk factor for increased volumetric material loss (P = .017). CONCLUSIONS: DM tribocorrosion with quantifiable material loss occurred more commonly in malseated liners. Specific design characteristics may make liners more prone to malseating, and the interplay between seating mechanics, liner characteristics, and patient factors likely contributes to the shell/liner tribocorrosion environment. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroplastia de Quadril , Ligas de Cromo , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Corrosão , Artroplastia de Quadril/instrumentação , Idoso , Pessoa de Meia-Idade , Feminino , Masculino , Idoso de 80 Anos ou mais , Titânio , Adulto , Estudos Retrospectivos
3.
J Arthroplasty ; 39(9S1): S183-S187, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38336305

RESUMO

BACKGROUND: Ceramic heads are frequently combined with titanium sleeves in revision total hip arthroplasties (THAs), ostensibly to protect the ceramic head from existing damage to the retained trunnion. Although widely adopted, data on the performance and safety of this construct are minimal. The purpose of this study was to describe implant survivorships, radiographic results, and clinical outcomes of patients who underwent revision THA with a ceramic head and titanium sleeve on a retained femoral component. METHODS: We identified 516 revision THAs with femoral component retention (328 acetabular-only revisions and 188 bearing surface exchanges) treated with a new ceramic head and titanium sleeve between 2000 and 2020. Mean age at revision was 64 years, 56% were women, and mean body mass index was 30. The indications for revision THA were adverse local tissue reaction (25%), acetabular loosening (24%), dislocation (17%), infection (5%), and other (29%). Kaplan-Meier survivorships were analyzed, radiographs reviewed, and Harris Hip Scores evaluated. Mean follow-up was 4 years (range, 2 to 10). RESULTS: There were no reoperations or failures for ceramic head fracture, taper corrosion, or head/sleeve disengagement. The 10-year survivorship free of any re-revision was 85%. Indications for the 57 re-revisions included dislocation (33), infection (13), acetabular component loosening (7), periprosthetic fracture (2), psoas impingement (1), and sciatic nerve irritation (1). The 10-year survivorship free of any reoperation was 82%. There were an additional 14 reoperations. Radiographically, 1.9% had progressive femoral radiolucent lines, and 4.7% had progressive acetabular radiolucent lines. Mean Harris Hip Score was 81 at 2 years. CONCLUSIONS: New ceramic heads with titanium sleeves in revision THAs with retained femoral components were durable and reliable with no cases of ceramic head fracture or taper complications at mean 4-year follow-up, including those revised for adverse local tissue reaction. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Cerâmica , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Reoperação , Titânio , Humanos , Reoperação/estatística & dados numéricos , Feminino , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Masculino , Idoso , Adulto , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem
4.
Arch Orthop Trauma Surg ; 143(6): 3649-3657, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36178493

RESUMO

INTRODUCTION: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. MATERIALS AND METHODS: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. RESULTS: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. CONCLUSION: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Ligas , Titânio , Sobrevivência , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Falha de Prótese , Reoperação/efeitos adversos
5.
J Arthroplasty ; 37(12): 2406-2411, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35738363

RESUMO

BACKGROUND: Revision total hip arthroplasty (THA) for adverse local tissue reactions (ALTRs) secondary to head-neck taper corrosion is associated with a high complication rate. Diagnosis of ALTR is based on risk stratification using the patient's history and examination, implant risk, serum metal ion levels, and imaging. The purpose of this study was to determine if stratification using similar risk factors is predictive of outcomes following revision THA for metal-on-polyethylene (MoP) ALTR. METHODS: We performed a retrospective review on 141 patients revised for ALTR due to head-neck taper corrosion. Pain outcomes following surgery were analyzed using a generalized linear mixed model. Complications were defined as instability/dislocation, infection, fracture, nerve palsy, leg-length discrepancy, or reoperation. RESULTS: The overall complication rate was 17.7%. The odds of having pain decreased by 44% after revision surgery (Odds Ratio = 0.56, 95% Confidence Interval: 0.324 to 0.952). There was no significant difference in instability/dislocation based on either increased or decreased head-neck offset (P = .67) or magnetic resonance imaging findings of abductor loss, effusion size, and degree of ALTR (P = .73). Increased serum cobalt (P = .31) and chromium (P = .08) levels did not predict complications; however, a decreased cobalt-chromium ratio was associated with postoperative complications (2.8 versus 3.5; P = .002). CONCLUSION: These findings are the first to suggest that patients who have ALTR after MoP THA undergoing revision surgery demonstrated major pain relief. Increasing femoral head offset did not change rates of instability/dislocation. In clinical scenarios where preoperative cobalt-chromium femoral head offsets were greater than available ceramic head offsets, a mandatory decrease in femoral head offset did not increase rates of instability/dislocation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Polietileno , Cobalto , Cromo , Corrosão , Metais , Medição de Risco , Dor/etiologia
6.
J Arthroplasty ; 37(8S): S941-S946, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34822931

RESUMO

BACKGROUND: One percent to 3% of contemporary non-cemented total hip arthroplasties (THAs) present with symptomatic mechanically assisted crevice corrosion (MACC). The incidence of this problem, however, as well as the rate of asymptomatic elevations in serum cobalt, is unknown. METHODS: Cobalt and chromium levels were obtained in conjunction with radiographs at routine 10-year surveillance follow-up of THAs from a single manufacturer with a titanium stem, cobalt alloy femoral head, and cross-linked polyethylene countersurface. RESULTS: Ten-year follow-up of patients with 162 consecutive THAs revealed that 17 patients with 18 hips had died of unrelated causes prior to metal ion testing. Two hips were revised for other reasons, and of the remaining 142 hips, 33 were in patients who were lost, leaving 109 hips (77% of those in alive patients and unrevised for other reasons and 67% of the entire cohort) for investigation. Sixty-three patients (58%) had a serum cobalt less than 1 ppb, and 35 (32%) a cobalt of ≥1 ppb, a cutoff consistent with MACC. Of the 32 hips with definite MACC, 15 of 32 (47%) patients were symptomatic, 16 of 30 (53%) patients had adverse local tissue reaction on magnetic resonance imaging, and 19 of 32 (59%) patients have undergone revision surgery for MACC to date. CONCLUSION: At 10-year follow-up, a minimum of 22% (35/162) of hips had a cobalt level more than 1 ppb, consistent with MACC. Symptoms and adverse local tissue reactions are each present about one-half of the time, and 59% of those with documented MACC have undergone revision.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Incidência , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos
7.
Arch Orthop Trauma Surg ; 142(10): 2577-2583, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33837474

RESUMO

INTRODUCTION: Recalls of total hip arthroplasty (THA) implants, including metal-on-metal (MoM) THA and dual taper stems, due to increased risk of adverse local tissue reaction (ALTR), represent a challenge for both surgeons and patients. This study aims to analyze the revision surgery outcomes for ALTR in patients with recalled THA implants. METHODS: A total of 118 consecutive patients who underwent revision surgery due to ALTR with recalled THA were analyzed. Sub-group analysis was performed for recalled MoM THAs, head-neck modular stems, and dual taper neck-stems. RESULTS: At a mean follow-up of 6.6 years, the complication and reoperation rates of the recalled THAs were 32.2% and 25.4% respectively. The most common post-revision complication was dislocation (16%). Revision of modular taper corrosion THA and high-grade intraoperative tissue damage were risk factors associated with post-revision complications. CONCLUSION: This study reports high complication and reoperation rates of recalled THAs at mid-term follow-up. The high revision surgery complication rates in both groups suggest the importance of a systematic evaluation of all THA patients with at-risk implants. LEVEL OF EVIDENCE: Level III, case control retrospective analysis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Próteses Articulares Metal-Metal/efeitos adversos , Metais , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos
8.
J Arthroplasty ; 36(7S): S358-S362, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33036841

RESUMO

BACKGROUND: Diagnosis of adverse local tissue reaction (ALTR) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper corrosion is challenging. The purpose of this study is to compare differences between asymptomatic and symptomatic ALTR in an observational cohort, including presentation, metal ion differences, and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) findings. METHODS: We performed a retrospective review of an observational cohort of 492 MoP THA patients at increased risk of developing ALTR. Ninety-four patients underwent revision arthroplasty for ALTR. Patients were stratified into symptomatic and asymptomatic ALTR groups. Presentation, metal ion levels, and imaging findings were compared. RESULTS: For patients with confirmed ALTR, 41% were asymptomatic. There was a statistically significant difference in the serum chromium levels between symptomatic and asymptomatic ALTR patients (2.2 µg/L vs 3.1 µg/L, P = .05). There was no statistically significant difference between the serum cobalt levels or MRI findings in these 2 groups. We observed that extracapsular disease associated with ALTR could be misinterpreted as trochanteric bursitis. CONCLUSION: Almost half of the MoP THA ALTR cases identified were asymptomatic. Cobalt levels could not differentiate between symptomatic and asymptomatic pseudotumor formation. Symptomatic and asymptomatic MoP ALTRs have similar MARS MRI characteristics. Our findings suggest that it is essential to risk stratify patients who could potentially have ALTR based on implant type, symptoms, ion levels, and MARS MRI.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto/efeitos adversos , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
9.
Genomics ; 111(6): 1404-1411, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30248488

RESUMO

Total hip arthroplasty (THA) alleviates hip pain and improves joint function. Current implant design permits long-term survivorship of THAs, but certain metal-on-metal (MoM) articulations can portend catastrophic failure due to adverse local tissue reactions (ALTR). Here, we identified biological and molecular differences between periacetabular synovial tissues of patients with MoM THA failure undergoing revision THA compared to patients undergoing primary THA for routine osteoarthritis (OA). Analysis of tissue biopsies by RNA-sequencing (RNA-seq) revealed that MoM patient samples exhibit significantly increased expression of immune response genes but decreased expression of genes related to extracellular matrix (ECM) remodeling. Thus, interplay between local tissue inflammation and ECM degradation may account for the pathology and compromised clinical outcomes in select patients with MoM implants. We conclude that adverse responses of host tissues to implant materials result in transcriptomic modifications in patients with MoM implants that permit consideration of strategies that could mitigate ECM damage.


Assuntos
Artroplastia de Quadril/efeitos adversos , Reação a Corpo Estranho/patologia , Próteses Articulares Metal-Metal/efeitos adversos , Osteoartrite/cirurgia , Falha de Prótese/etiologia , Sinoviócitos/patologia , Transcriptoma , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/metabolismo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/patologia , Patologia Molecular , Reoperação , Sinoviócitos/metabolismo
10.
J Arthroplasty ; 35(12): 3686-3691, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32654942

RESUMO

BACKGROUND: Treatment of adverse local tissue reaction (ALTR) is challenging owing to high complications and poor outcomes after a revision surgery. As dislocation is the most common cause of reoperation, it is often necessary to use advanced articulations such as dual mobility. This study aims to evaluate the outcome and complication rates after revision surgery with dual mobility constructs, compared to constrained and conventional articulations in the setting of significant abductor deficiency due to ALTR. METHODS: Out of a total of 338 revision total hip arthroplasties for ALTR, 234 patients with a significant tissue necrosis and abductor muscle insufficiency (grade 3) were evaluated. The complication rates after revisions were compared between 42 hips with dual mobility implants, 24 hips with constrained liners, 104 hips with large diameter heads (36-40 mm), and 64 hips with small diameter heads (≤32 mm). RESULTS: After an average of 4 years of follow-up (2.8-8.6), the dual mobility articulation had no dislocation, compared to 4.1% and 15.5% for constrained liner and conventional articulations, respectively (P < .001). Utilization of dual mobility and constrained liner cup also did not increase the risk of nondislocation complications, including periprosthetic joint infection and periprosthetic fracture (P = .18 and .52). CONCLUSIONS: This study demonstrates significantly lower dislocation rates for dual mobility when compared to conventional articulations and comparable to constrained liners in cases of severe abductor deficiency due to ALTR, suggesting that dual mobility implants are viable surgical treatment alternatives to constrained liners to minimize dislocation during revision total hip arthroplasty in the setting of significant abductor deficiency due to ALTR.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA