Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pharm Res ; 41(1): 153-163, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37923948

RESUMO

PURPOSE: We fabricated and characterized polyvinyl alcohol (PVA)-based dissolving microneedles (MNs) for transdermal drug delivery of apomorphine hydrochloride (APO), which is used in treating the wearing-off phenomenon observed in Parkinson's disease. METHODS: We fabricated MN arrays with 11 × 11 needles of four different lengths (300, 600, 900, and 1200 µm) by micromolding. The APO-loaded dissolving MNs were characterized in terms of their physicochemical and functional properties. We also compared the pharmacokinetic parameters after drug administration using MNs with those after subcutaneous injection by analyzing the blood concentration of APO in rats. RESULTS: PVA-based dissolving MNs longer than 600 µm could effectively puncture the stratum corneum of the rat skin with penetrability of approximately one-third of the needle length. Although APO is known to have chemical stability issues in aqueous solutions, the drug content in APO-loaded MNs was retained at 25°C for 12 weeks. The concentration of APO after the administration of APO-loaded 600-µm MNs that dissolved completely in skin within 60 min was 81%. The absorption of 200-µg APO delivered by MNs showed a Tmax of 20 min, Cmax of 76 ng/mL, and AUC0-120 min of 2,829 ng・min/mL, compared with a Tmax of 5 min, Cmax of 126 ng/mL, and AUC0-120 min of 3,224 ng・min/mL for subcutaneous injection. The bioavailability in terms of AUC0-120 min of APO delivered by MNs was 88%. CONCLUSION: APO-loaded dissolving MNs can deliver APO via skin into the systemic circulation with rapid absorption and high bioavailability.


Assuntos
Apomorfina , Doença de Parkinson , Ratos , Animais , Apomorfina/farmacologia , Sistemas de Liberação de Medicamentos , Doença de Parkinson/tratamento farmacológico , Administração Cutânea , Pele
2.
Proc Natl Acad Sci U S A ; 118(45)2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34670842

RESUMO

Vaccination against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other pathogens with pandemic potential requires safe, protective, inexpensive, and easily accessible vaccines that can be developed and manufactured rapidly at a large scale. DNA vaccines can achieve these criteria, but induction of strong immune responses has often required bulky, expensive electroporation devices. Here, we report an ultra-low-cost (<1 USD), handheld (<50 g) electroporation system utilizing a microneedle electrode array ("ePatch") for DNA vaccination against SARS-CoV-2. The low cost and small size are achieved by combining a thumb-operated piezoelectric pulser derived from a common household stove lighter that emits microsecond, bipolar, oscillatory electric pulses and a microneedle electrode array that targets delivery of high electric field strength pulses to the skin's epidermis. Antibody responses against SARS-CoV-2 induced by this electroporation system in mice were strong and enabled at least 10-fold dose sparing compared to conventional intramuscular or intradermal injection of the DNA vaccine. Vaccination was well tolerated with mild, transient effects on the skin. This ePatch system is easily portable, without any battery or other power source supply, offering an attractive, inexpensive approach for rapid and accessible DNA vaccination to combat COVID-19, as well as other epidemics.


Assuntos
Vacinas contra COVID-19/administração & dosagem , COVID-19/imunologia , COVID-19/prevenção & controle , Eletroporação/instrumentação , SARS-CoV-2 , Vacinas de DNA/administração & dosagem , Animais , Vacinas contra COVID-19/genética , Vacinas contra COVID-19/imunologia , Custos e Análise de Custo , Eletroporação/economia , Eletroporação/métodos , Desenho de Equipamento , Feminino , Genes Reporter , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Microeletrodos , Agulhas , Pandemias/prevenção & controle , Estudo de Prova de Conceito , Ratos , Ratos Wistar , Pele/imunologia , Pele/metabolismo , Transfecção , Vacinação/economia , Vacinação/instrumentação , Vacinação/métodos , Vacinas de DNA/genética , Vacinas de DNA/imunologia
3.
Sensors (Basel) ; 24(12)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38931517

RESUMO

This study integrates hollow microneedle arrays (HMNA) with a novel jellyfish-shaped electrochemical sensor for the detection of key biomarkers, including uric acid (UA), glucose, and pH, in artificial interstitial fluid. The jellyfish-shaped sensor displayed linear responses in detecting UA and glucose via differential pulse voltammetry (DPV) and chronoamperometry, respectively. Notably, the open circuit potential (OCP) of the system showed a linear variation with pH changes, validating its pH-sensing capability. The sensor system demonstrates exceptional electrochemical responsiveness within the physiological concentration ranges of these biomarkers in simulated epidermis sensing applications. The detection linear ranges of UA, glucose, and pH were 0~0.8 mM, 0~7 mM, and 4.0~8.0, respectively. These findings highlight the potential of the HMNA-integrated jellyfish-shaped sensors in real-world epidermal applications for comprehensive disease diagnosis and health monitoring.


Assuntos
Biomarcadores , Técnicas Biossensoriais , Técnicas Eletroquímicas , Líquido Extracelular , Agulhas , Líquido Extracelular/química , Biomarcadores/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Concentração de Íons de Hidrogênio , Glucose/análise , Ácido Úrico/análise , Animais , Humanos
4.
Biochem Biophys Res Commun ; 686: 149179, 2023 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-37922572

RESUMO

Direct delivery of genome-editing proteins into plant tissues could be useful in obtaining DNA-free genome-edited crops obviating the need for backcrossing to remove vector-derived DNA from the host genome as in the case of genetically modified organisms generated using DNA vector. Previously, we successfully delivered Cas9 ribonucleoprotein (RNP) into plant tissue by inserting microneedle array (MNA) physisorbed with Cas9 RNPs. Here, to enhance protein delivery and improve genome-editing efficiency, we introduced a bioactive polymer DMA/HPA/NHS modification to the MNA, which allowed strong bonding between the proteins and MNA. Compared with other modifying agents, this MNA modification resulted in better release of immobilized protein in a plant cytosol-mimicking environment. The delivery of Cas9 RNPs in Arabidopsis thaliana reporter plants was improved from 4 out of 17 leaf tissues when using unmodified MNAs to 9 out of 17 when using the polymer-modified MNAs. Further improvements in delivery efficiency can be envisaged by optimizing the polymer modification conditions, which could have significant implications for the development of more effective plant genome editing techniques.


Assuntos
Sistemas CRISPR-Cas , Edição de Genes , Edição de Genes/métodos , Ribonucleoproteínas/genética , Ribonucleoproteínas/metabolismo , Citosol/metabolismo , Preparações de Ação Retardada , DNA , Genoma de Planta/genética
5.
Biomed Microdevices ; 24(3): 27, 2022 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-35953589

RESUMO

To acquire high-quality electrocardiogram (ECG) signals, traditional Ag/AgCl wet electrodes used together with conductive gel can effectively reduce electrode-skin interface impedance (EII) in a short term. However, their weaknesses of poor flexibility and instability can no longer meet the long-term monitoring requirements of intelligent wearable devices. Owing to the flexible dry electrode without conductive gel, it is a good choice to solve the critical problem on drying-out of conductive gel. Therefore, we develop a flexible microneedle array electrode (FMAE) based on polydimethylsiloxane (PDMS) substrate, which obtains reliable bioelectrical signals by way of penetrating into the stratum corneum (SC) of the skin. The fabrication process, including silicon mold, twice PDMS shape-transferring and encapsulation, has advantages of low cost, repeatable production and good biocompatibility. Afterwards, by comparing the performance with different electrodes, impedance test results indicate that the impedance of FMAE are smaller and more stable, and ECG tests in long term and at resting/jogging states also verify that FMAE can obtain durable, stable and reliable signals. In conclusion, FMAE is promising in long-term ECG monitoring.


Assuntos
Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Dimetilpolisiloxanos , Impedância Elétrica , Eletrodos
6.
Mol Pharm ; 19(4): 1191-1208, 2022 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-35235330

RESUMO

The need for biocompatible polymers capable of dissolving in the skin while exhibiting reasonable mechanical features and delivery efficiency limits the range of materials that could be utilized in fabricating dissolving microneedle array patches (MAPs). The incorporation of additives, such as surfactants, during microneedle fabrication might be an alternative solution to overcome the limited range of materials used in fabricating dissolving MAPs. However, there is a lacuna in the knowledge on the effect of surfactants on the manufacture and performance of dissolving MAPs. The current study explores the role of surfactants in the manufacture and performance of dissolving MAPs fabricated from poly(vinyl alcohol) (PVA) and poly(vinyl pyrrolidone) (PVP) loaded with the model drugs, ibuprofen sodium and itraconazole. Three nonionic surfactants, Lutrol F108, Pluronic F88, and Tween 80, in solutions at varying concentrations (0.5, 1.0, and 2.0% w/w) were loaded into these dissolving MAPs. It was discovered that all of the dissolving MAPs that incorporated surfactant displayed a lower reduction in the microneedle height (≈10%) relative to the control formulation (≈20%) when subjected to a compressive force of 32 N. In addition, the incorporation of surfactants in some instances enhanced the insertion profile of these polymeric MAPs when evaluated using ex vivo neonatal porcine skin. The incorporation of surfactant into ibuprofen sodium-loaded dissolving MAPs improved the insertion depth of MAPs from 400 µm down to 600 µm. However, such enhancement was not apparent when the MAPs were loaded with the model hydrophobic drug, itraconazole. Skin deposition studies highlighted that the incorporation of surfactant enhanced the delivery efficiency of both model drugs, ibuprofen sodium and itraconazole. The incorporation of surfactant enhanced the amount of ibuprofen sodium delivered from 60.61% up to ≈75% with a majority of the drug being delivered across the skin and into the receptor compartment. On the other hand, when surfactants were added into MAPs loaded with the model hydrophobic drug itraconazole, we observed enhancement in intradermal delivery efficiency from 20% up to 30%, although this did not improve the delivery of the drug across the skin. This work highlights that the addition of nonionic surfactant is an alternative formulation strategy worth exploring to improve the performance and delivery efficiency of dissolving MAPs.


Assuntos
Sistemas de Liberação de Medicamentos , Tensoativos , Administração Cutânea , Animais , Microinjeções , Agulhas , Pele/metabolismo , Tensoativos/metabolismo , Suínos
7.
Sensors (Basel) ; 22(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35214368

RESUMO

Lactate measurement is important in the fields of sports and medicine. Lactate accumulation can seriously affect an athlete's performance. The most common problem caused by lactate accumulation in athletes is muscle soreness due to excessive exercise. Moreover, from a medical viewpoint, lactate is one of the main prognostic factors of sepsis. Currently, blood sampling is the most common approach to lactate measurement for lactate sensing, and continuous measurement is not available. In this study, a low-cost continuous lactate monitoring system (CLMS) is developed based on a percutaneous microneedle array that uses a three-electrode lactate sensor. The working electrode has an area of 10 mm × 6 mm, including a 3 × 3 array of stainless-steel microneedles. The length, width, and thickness of each needle are 1 mm, 0.44 mm, and 0.03 mm, respectively. The working electrode is then plated with gold, polyaniline, lactate enzyme, Nafion, and Poly(2-hydroxyethyl methacrylate) (poly HEMA). The reference electrode is a 2 × 1 array covered with AgCl, and the counter electrode is a 2 × 1 array plated with gold. The sensor is incorporated into the CLMS and connected to a smartphone application and the cloud. The CLMS was tested on 40 human subjects who rode indoor bicycles, starting at 100 W and increasing in steps of 25 W at intervals of 5 min until exhaustion. The data acquired from the app connected to the CLMS were analyzed to determine the subjects' lactate response to exercise and the feasibility of assessing exercise performance and training exercise intensity by using the proposed system.


Assuntos
Técnicas Biossensoriais , Ácido Láctico , Eletrodos , Ouro , Humanos , Monitorização Fisiológica
8.
Connect Tissue Res ; 61(2): 229-243, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31134817

RESUMO

Purpose: Scaffold-free cartilage tissue engineering circumvents issues with scaffold seeding, potential toxicity response, and impaired host integration. However, precisely controlling and maintaining a scaffold-free construct shape have been challenging. We explored the feasibility of microneedle arrays to print tissue using cellular microspheroids as building blocks.Materials and Methods: Human embryonic-derived mesenchymal stem cells or infrapatellar fat pad mesenchymal stem cells were used to create microspheroids of 500 µm in diameter, which were assembled on microneedle arrays in a predefined arrangement using a robotic system under computer vision. Microspheroids on microneedles were cultured to permit fusion into a tissue construct. Infrapatellar fat pad mesenchymal stem cell constructs were either implanted into chondral defects created in human osteoarthritic cartilage explants or maintained on the microneedle array for 3 weeks. Embryonic-derived mesenchymal stem cell constructs were designed to be press-fit into 3 mm subchondral defects in New Zealand White rabbits and maintained for up to 8 weeks to assess retention, early tissue repair, and more mature cartilage regeneration.Results: Microspheroids of both cell types fused together in culture to form neotissues of predefined shape and size. Infrapatellar fat pad mesenchymal stem cell neotissues expressed high levels of chondrogenic genes and integrated with the surrounding osteoarthritic host cartilage. Embryonic-derived mesenchymal stem cell constructs generated chondrogenic neotissue in vivo as early as 2 weeks and more mature tissue by 8 weeks with increased glycosaminoglycan deposition.Conclusions: We constructed defined scaffold-free shapes by bioprinting and fusing microspheroids. Proof of concept was shown in the repair of ex vivo osteoarthritic human cartilage and in vivo rabbit osteochondral (OC) defects.


Assuntos
Cartilagem , Condrogênese , Células-Tronco Embrionárias Humanas/metabolismo , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/metabolismo , Osteoartrite , Procedimentos Cirúrgicos Robóticos , Engenharia Tecidual , Idoso , Animais , Cartilagem/lesões , Cartilagem/metabolismo , Cartilagem/patologia , Feminino , Células-Tronco Embrionárias Humanas/patologia , Humanos , Masculino , Células-Tronco Mesenquimais/patologia , Pessoa de Meia-Idade , Agulhas , Osteoartrite/metabolismo , Osteoartrite/patologia , Osteoartrite/terapia , Coelhos
9.
Pharm Res ; 37(9): 174, 2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-32856172

RESUMO

PURPOSE: To apply a simple and flexible manufacturing technique, two-photon polymerisation (2PP), to the fabrication of microneedle (MN) array templates with high precision and low cost in a short time. METHODS: Seven different MN array templates were produced by 2PP 3D printing, varying needle height (900-1300 µm), shape (conical, pyramidal, cross-shaped and with pedestal), base width (300-500 µm) and interspacing (100-500 µm). Silicone MN array moulds were fabricated from these templates and used to produce dissolving and hydrogel-forming MN arrays. These polymeric MN arrays were evaluated for their insertion in skin models and their ability to deliver model drugs (cabotegravir sodium and ibuprofen sodium) to viable layers of the skin (ex vivo and in vitro) for subsequent controlled release and/or absorption. RESULTS: The various templates obtained with 2PP 3D printing allowed the reproducible fabrication of multiple MN array moulds. The polymeric MN arrays produced were efficiently inserted into two different skin models, with sharp conical and pyramidal needles showing the highest insertion depth values (64-90% of needle height). These results correlated generally with ex vivo and in vitro drug delivery results, where the same designs showed higher drug delivery rates after 24 h of application. CONCLUSION: This work highlights the benefits of using 2PP 3D printing to prototype variable MN array designs in a simple and reproducible manner, for their application in drug delivery.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Impressão Tridimensional/instrumentação , Pele/metabolismo , Administração Cutânea , Animais , Hidrogéis , Microinjeções/instrumentação , Modelos Biológicos , Agulhas , Polimerização , Polímeros/química , Suínos
10.
AAPS PharmSciTech ; 22(1): 1, 2020 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-33215299

RESUMO

Salmon calcitonin (sCT) is a polypeptide drug, possessing the ability to inhibit osteoclast-mediated bone resorption. Just like other bioactive macromolecules, sCT is generally administered to the patients by either injection for poor compliance or through nasal spray for low bioavailability, which limits its use as therapeutic drugs. In the present study, to overcome the limitations of the conventional routes, two new dissolving microneedle arrays (DMNAs) based on transdermal sCT delivery systems were developed, namely sCT-DMNA-1 (sCT/Dex/K90E) and sCT-DMNA-2 (sCT/Dex-Tre/K90E) with the same dimension, meeting the requirements of suitable mechanical properties. An accurate and reliable method was established to determine the needle drug loading proportion in sCT-DMNAs. The stability study exhibited that the addition of trehalose could improve the stability of sCT in DMNA under high temperature and humidity. Further, in vivo pharmacodynamic study revealed that DMNA patch could significantly enhanced relative bioavailability to approximately 70%, and the addition of trehalose was found to be beneficial for sCT transdermal delivery. Therefore, sCT-DMNA is expected to replace traditional dosage form, providing a secure, efficient, and low-pain therapeutic strategy for bone disorders.


Assuntos
Calcitonina/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Agulhas , Administração Cutânea , Animais , Feminino , Humanos , Ratos , Ratos Sprague-Dawley , Suínos
11.
Sensors (Basel) ; 18(4)2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29652837

RESUMO

Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE) was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 µm and a base diameter of 200 µm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C) and forearm temperature (35.3 °C) are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals.


Assuntos
Eletrodos , Agulhas , Temperatura
12.
Sensors (Basel) ; 18(4)2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29652835

RESUMO

Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode-skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

13.
Sensors (Basel) ; 18(1)2017 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-29301203

RESUMO

Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user's movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclosed in wet electrodes restricts spatial resolution, and these conventional bulky systems limit natural movements. In this paper, a microneedle-based high-density electrode array on a circuit integrated flexible substrate for sEMG is proposed. Microneedles allow for high spatial resolution without requiring conductive substances, and flexible substrates guarantee stable skin-electrode contact. Moreover, a compact signal processing system is integrated with the electrode array. Therefore, sEMG measurements are comfortable to the user and do not interfere with the movement. The system performance was demonstrated by testing its operation and estimating motion using a Gaussian mixture model-based, simplified 2D spatial pattern.


Assuntos
Eletrodos , Eletromiografia , Movimento , Músculo Esquelético , Agulhas , Processamento de Sinais Assistido por Computador
14.
Mol Pharm ; 13(1): 272-9, 2016 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-26649921

RESUMO

The purpose of this study was to evaluate the characteristics of exendin-4 tip-loaded microneedle arrays and to compare their acute efficacy with subcutaneous injections in type 2 diabetic GK/Slc rats. Fluorescein isothiocyanate labeled dextran with an average molecular weight of 4,000 (FD4) was selected as a model drug, and FD4 tip-loaded microneedle arrays were prepared in this study. In addition, intraperitoneal glucose tolerance tests after application of exendin-4 tip-loaded microneedle arrays were also compared with those after subcutaneous injection in type 2 diabetic GK/Slc rats. The release of FD4 from the tip-loaded microneedle arrays was very rapid, particularly in the initial 30 s, and most of the FD4 was released within 5 min. In addition, glucose tolerance was improved and the insulin secretion was enhanced after application of exendin-4 tip-loaded microneedle arrays, and these effects were comparable to those after subcutaneous injection of exendin-4. Similar plasma concentration profiles were seen after application of exendin-4 tip-loaded microneedle arrays, as was the case with subcutaneous injection in type 2 diabetic GK/Slc rats. These findings indicate that exendin-4 tip-loaded microneedle arrays can be used as an alternative to achieve sufficient delivery of exendin-4 for treatment of type 2 diabetes. To our knowledge, this is the first report of transdermal exendin-4 delivery using tip-loaded microneedle arrays.


Assuntos
Administração Cutânea , Ácido Hialurônico/química , Peptídeos/administração & dosagem , Peptídeos/química , Peçonhas/administração & dosagem , Peçonhas/química , Animais , Exenatida , Masculino , Ratos , Ratos Wistar , Absorção Cutânea
15.
Sensors (Basel) ; 15(7): 16265-80, 2015 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-26153773

RESUMO

Surface electromyography is widely used in many fields to infer human intention. However, conventional electrodes are not appropriate for long-term measurements and are easily influenced by the environment, so the range of applications of sEMG is limited. In this paper, we propose a flexible band-integrated, curved microneedle array electrode for robust long-term measurements, high selectivity, and easy applicability. Signal quality, in terms of long-term usability and sensitivity to perspiration, was investigated. Its motion-discriminating performance was also evaluated. The results show that the proposed electrode is robust to perspiration and can maintain a high-quality measuring ability for over 8 h. The proposed electrode also has high selectivity for motion compared with a commercial wet electrode and dry electrode.


Assuntos
Eletromiografia/instrumentação , Agulhas , Eletrodos , Humanos , Microtecnologia/instrumentação
16.
Ultrasonics ; 141: 107344, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38772060

RESUMO

Ultrasonic microneedle patches, a class of ultrasound-driven transdermal drug delivery systems, are promising in addressing bacterial biofilms. This device has been proven to be more effective in treating Staphylococcus aureus biofilms than drug in free solution. However, there exists a notable gap in understanding how various excitation conditions and material parameters affect drug delivery efficiency. This study aims to fill this void by conducting an comprehensive multi-physics numerical analysis of ultrasonic microneedle patches, with the ultimate goal of enhancing drug delivery. First, we investigate the impact of various ultrasound frequencies on drug penetration depths. The findings reveal that local resonance can accelerate drug release within a shorter time window (first 1.5 h), whereas non-resonant frequencies enable more profound and prolonged diffusion. This information is crucial for medical professionals in selecting the most effective frequency for optimal drug administration. Furthermore, our investigation extends to the effects of applied voltage on temperature distribution, a critical aspect for ensuring medical safety during the application of these patches. Additionally, we examine how particles of different sizes respond to acoustic pressure and streaming fields, providing valuable insights for tailoring drug delivery strategies to specific therapeutic needs. Overall, our findings offer comprehensive guidelines for the effective use of ultrasonic microneedle patches, potentially shifting the paradigm in patient care and enhancing the overall quality of life.


Assuntos
Biofilmes , Sistemas de Liberação de Medicamentos , Agulhas , Staphylococcus aureus , Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Staphylococcus aureus/fisiologia , Ondas Ultrassônicas , Antibacterianos/administração & dosagem , Administração Cutânea
17.
Eur J Pharm Biopharm ; 202: 114415, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39013492

RESUMO

Hydrogel-forming microneedle array patches (HFMAPs) are microneedles that create microconduits upon insertion and swelling in the skin, potentially allowing prolonged drug delivery without generating sharps waste. Delivering hydrophobic drugs using HFMAPs poses challenges, which can be addressed using solubility enhancers such as cyclodextrins (CDs). This study aimed to deliver risperidone (RIS) transdermally using HFMAPs. To enhance the aqueous solubility of RIS hydroxypropyl-beta-cyclodextrin (HP-ß-CD) and hydroxypropyl-gamma-cyclodextrin (HP-γ-CD) were utilised and their performance was tested using phase solubility studies. The aqueous solubility of RIS was enhanced by 4.75-fold and 2-fold using HP-ß-CD and HP-γ-CD, respectively. RIS-HP-ß-CD complex (CX) and physical mixture (PM) directly compressed tablets were prepared and combined with HFMAPs. Among the tested formulations, RIS-HP-ß-CD PM reservoirs with 11 x 11 PVA/PVP HFMAPs exhibited the best performance in ex vivo studies and were further evaluated in in vivo experiments using female Sprague Dawley rats. The extended wear time of the MAPs resulted in the sustained release of RIS and its active metabolite 9-hydroxyrisperidone (9-OH-RIS) in plasma samples, lasting from 3 to 5 days with a 1-day application and up to 10 days with a 5-day application. For a 1-day application, HFMAPs showed greater systemic exposure to RIS compared to intramuscular control (AUC0-t: 13330.05 ± 2759.95 ng/mL/hour versus 2706 ± 1472 ng/mL/hour). Moreover, RIS exposure was extended to 5 days (AUC0-t: 12292.37 ± 1801.94 ng/mL/hour). In conclusion, HFMAPs could serve as an alternative for delivering RIS in a sustained manner, potentially improving the treatment of schizophrenia.


Assuntos
2-Hidroxipropil-beta-Ciclodextrina , Administração Cutânea , Sistemas de Liberação de Medicamentos , Hidrogéis , Risperidona , Solubilidade , Risperidona/administração & dosagem , Risperidona/farmacocinética , Risperidona/química , Animais , Hidrogéis/química , Sistemas de Liberação de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/instrumentação , 2-Hidroxipropil-beta-Ciclodextrina/química , Ratos , Agulhas , Ratos Sprague-Dawley , Absorção Cutânea , Ciclodextrinas/química , Antipsicóticos/administração & dosagem , Antipsicóticos/farmacocinética , Feminino , Pele/metabolismo
18.
ACS Sens ; 9(2): 932-941, 2024 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-38252743

RESUMO

Microneedle-based wearable electrochemical biosensors are the new frontier in personalized health monitoring and disease diagnostic devices that provide an alternative tool to traditional blood-based invasive techniques. Advancements in micro- and nanofabrication technologies enabled the fabrication of microneedles using different biomaterials and morphological features with the aim of overcoming existing challenges and enhancing sensing performance. In this work, we report a microneedle array featuring conductive recessed microcavities for monitoring urea levels in the interstitial fluid of the skin. Microcavities are small pockets on the tip of each microneedle that can accommodate the sensing layer, provide protection from delamination during skin insertion or removal, and position the sensing layer in a deep layer of the skin to reach the interstitial fluid. The wearable urea patch has shown to be highly sensitive and selective in monitoring urea, with a sensitivity of 2.5 mV mM-1 and a linear range of 3 to 18 mM making it suitable for monitoring urea levels in healthy individuals and patients. Our ex vivo experiments have shown that recessed microcavities can protect the sensing layer from delamination during skin insertion and monitor changing urea levels in interstitial fluid. This biocompatible platform provides alternative solutions to the critical issue of maintaining the performance of the biosensor upon skin insertion and holds great potential for advancing transdermal sensor technology.


Assuntos
Líquido Extracelular , Dispositivos Eletrônicos Vestíveis , Humanos , Pele , Materiais Biocompatíveis , Ureia
19.
Drug Deliv Transl Res ; 14(11): 2989-3008, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38509342

RESUMO

Diabetes currently affects approximately 500 million people worldwide and is one of the most common causes of mortality in the United States. To diagnose and monitor diabetes, finger-prick blood glucose testing has long been used as the clinical gold standard. For diabetes treatment, insulin is typically delivered subcutaneously through cannula-based syringes, pens, or pumps in almost all type 1 diabetic (T1D) patients and some type 2 diabetic (T2D) patients. These painful, invasive approaches can cause non-adherence to glucose testing and insulin therapy. To address these problems, researchers have developed miniaturized blood glucose testing devices as well as microfluidic platforms for non-invasive glucose testing through other body fluids. In addition, glycated hemoglobin (HbA1c), insulin levels, and cellular biomechanics-related metrics have also been considered for microfluidic-based diabetes diagnosis. For the treatment of diabetes, insulin has been delivered transdermally through microdevices, mostly through microneedle array-based, minimally invasive injections. Researchers have also developed microfluidic platforms for oral, intraperitoneal, and inhalation-based delivery of insulin. For T2D patients, metformin, glucagon-like peptide 1 (GLP-1), and GLP-1 receptor agonists have also been delivered using microfluidic technologies. Thus far, clinical studies have been widely performed on microfluidic-based diabetes monitoring, especially glucose sensing, yet technologies for the delivery of insulin and other drugs to diabetic patients with microfluidics are still mostly in the preclinical stage. This article provides a concise review of the role of microfluidic devices in the diagnosis and monitoring of diabetes, as well as the delivery of pharmaceuticals to treat diabetes using microfluidic technologies in the recent literature.


Assuntos
Hipoglicemiantes , Insulina , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Animais , Técnicas Analíticas Microfluídicas/instrumentação , Glicemia/análise , Microfluídica/métodos , Dispositivos Lab-On-A-Chip , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/terapia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Sistemas de Liberação de Medicamentos/instrumentação
20.
Adv Sci (Weinh) ; 11(31): e2309940, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38874114

RESUMO

Liver fibrosis is a chronic pathological condition lacking specific clinical treatments. Stem cells, with notable potential in regenerative medicine, offer promise in treating liver fibrosis. However, stem cell therapy is hindered by potential immunological rejection, carcinogenesis risk, efficacy variation, and high cost. Stem cell secretome-based cell-free therapy offers potential solutions to address these challenges, but it is limited by low delivery efficiency and rapid clearance. Herein, an innovative approach for in situ implantation of smart microneedle (MN) arrays enabling precisely controlled delivery of multiple therapeutic agents directly into fibrotic liver tissues is developed. By integrating cell-free and platinum-based nanocatalytic combination therapy, the MN arrays can deactivate hepatic stellate cells. Moreover, they promote excessive extracellular matrix degradation by more than 75%, approaching normal levels. Additionally, the smart MN arrays can provide hepatocyte protection while reducing inflammation levels by ≈70-90%. They can also exhibit remarkable capability in scavenging almost 100% of reactive oxygen species and alleviating hypoxia. Ultimately, this treatment strategy can effectively restrain fibrosis progression. The comprehensive in vitro and in vivo experiments, supplemented by proteome and transcriptome analyses, substantiate the effectiveness of the approach in treating liver fibrosis, holding immense promise for clinical applications.


Assuntos
Cirrose Hepática , Agulhas , Animais , Cirrose Hepática/terapia , Camundongos , Modelos Animais de Doenças , Humanos , Masculino , Sistema Livre de Células
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA