Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 531
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Nano Lett ; 24(1): 89-96, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-37939013

RESUMO

The ability to target specific tissues and to be internalized by cells is critical for successful nanoparticle-based targeted drug delivery. Here, we combined "stealthy" rod-shaped poly(2-oxazoline) (POx) nanoparticles of different lengths with a cancer marker targeting nanobody and a fluorescent cell internalization sensor via a heat-induced living crystallization-driven self-assembly (CDSA) strategy. A significant increase in association and uptake driven by nanobody-receptor interactions was observed alongside nanorod-length-dependent kinetics. Importantly, the incorporation of the internalization sensor allowed for quantitative differentiation between cell surface association and internalization of the targeted nanorods, revealing unprecedented length-dependent cellular interactions of CDSA nanorods. This study highlights the modularity and versatility of the heat-induced CDSA process and further demonstrates the potential of POx nanorods as a modular nanomedicine platform.


Assuntos
Nanopartículas , Nanotubos , Sistemas de Liberação de Medicamentos , Membrana Celular
2.
Small ; 20(27): e2310300, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38299477

RESUMO

Glutathione (GSH) is the primary antioxidant in cells, and GSH consumption will break the redox balance in cells. Based on this, a method that uses high concentrations of GSH in the tumor microenvironment to trigger the redox reaction of Cu(II) to generate copper nanoprobes with fluorescence and tumor growth inhibition properties is proposed. The nanoprobe mainly exists in the form of Cu(I) and catalyzes the decomposition of hydrogen peroxide into hydroxyl radicals. At the same time, a simple and controllable carbon micro-nano electrode is used to construct a single-cell sensing platform, which enable the detection of glutathione content in single living cells after Cu(II) treatment, providing an excellent example for detecting single-cell biomolecules.


Assuntos
Cobre , Glutationa , Glutationa/metabolismo , Cobre/química , Humanos , Neoplasias/metabolismo , Técnicas Biossensoriais/métodos , Linhagem Celular Tumoral , Animais , Oxirredução , Espaço Intracelular/metabolismo
3.
Chembiochem ; 25(14): e202400254, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38757240

RESUMO

In this work, a highly sensitive and selective method for detecting folic acid (FA) was developed using D-penicillamine (DPA) stabilized Ag/Cu alloy nanoclusters (DPA@Ag/Cu NCs). The yellow emission of DPA@Ag/Cu NCs was found to be quenched upon the addition of FA to the system. The fluorescence intensity quenching value demonstrated a linear relationship with FA concentrations ranging from 0.01 to 1200 µM, with a limit of detection (LOD) of 5.3 nM. Furthermore, the detection mechanism was investigated through various characterization analyses, including high resolution transmission electron microscopy, fluorescence spectra, ultraviolet-visible absorption spectra, and fluorescence lifetime. The results indicated that the fluorescence quenching induced by FA was a result of electron transfer from FA to the ligands of DPA@Ag/Cu NCs. The selectivity of the FA sensor was also evaluated, showing that common amino acids and inorganic ions had minimal impact on the detection of FA. Moreover, the standard addition method was successfully applied to detect FA in human serum, chewable tablets and FA tablets with promising results. The use of DPA@Ag/Cu NCs demonstrates significant potential for detecting FA in complex biological samples.


Assuntos
Ligas , Cobre , Corantes Fluorescentes , Ácido Fólico , Penicilamina , Prata , Espectrometria de Fluorescência , Penicilamina/análise , Penicilamina/química , Penicilamina/sangue , Cobre/química , Ácido Fólico/análise , Ácido Fólico/química , Ácido Fólico/sangue , Prata/química , Humanos , Ligas/química , Corantes Fluorescentes/química , Limite de Detecção , Nanopartículas Metálicas/química , Comprimidos/análise
4.
New Phytol ; 242(2): 453-465, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38413216

RESUMO

The water status of the living tissue in leaves is critical in determining plant function and global exchange of water and CO2. Despite significant advances in the past two decades, persistent questions remain about the tissue-specific origins of leaf hydraulic properties and their dependence on water status. We use a fluorescent nanoparticle reporter that provides water potential in the mesophyll apoplast adjacent to the epidermis of intact leaves to complement existing methods based on the Scholander Pressure Chamber (SPC). Working in tomato leaves, this approach provides access to the hydraulic conductance of the whole leaf, xylem, and outside-xylem tissues. These measurements show that, as stem water potential decreases, the water potential in the mesophyll apoplast can drop below that assessed with the SPC and can fall significantly below the turgor loss point of the leaf. We find that this drop in potential, dominated by the large loss (10-fold) of hydraulic conductance of the outside-xylem tissue, is not however strong enough to significantly limit transpiration. These observations highlight the need to reassess models of water transfer through the outside-xylem tissues, the potential importance of this tissue in regulating transpiration, and the power of new approaches for probing leaf hydraulics.


Assuntos
Solanum lycopersicum , Folhas de Planta/fisiologia , Água/fisiologia , Xilema/fisiologia , Transpiração Vegetal
5.
Artigo em Inglês | MEDLINE | ID: mdl-38961530

RESUMO

The incidence of thyroid tumors has been increasing yearly over the past decade, making it the fourth highest tumor in women. This places various biological burdens on those affected. Currently, thyroid tumors are primarily diagnosed using percutaneous fine needle aspiration and ultrasound. However, these methods are complex, expensive, and less accurate, and they may fail to detect some thyroid nodules. As an alternative, researchers are focusing on blood-based biomarkers in addition to the traditional diagnostic methods, assisted predominantly by nanomaterials. Early identification of thyroid cancer is crucial as it is highly treatable. Various sensing systems have been developed using nanomaterial-mediated approaches to enhance the detection system. Nanomaterials are effectively applied in biosensors for surface functionalization and are conjugated with biomolecules to improve the interaction with the target analyte. This review discusses nanomaterial-assisted thyroid tumor detection, with a special focus on nanomaterial-based biosensors.

6.
Proc Natl Acad Sci U S A ; 118(14)2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33795516

RESUMO

The ability to monitor the release of neurotransmitters during synaptic transmission would significantly impact the diagnosis and treatment of neurological diseases. Here, we present a DNA-based enzymatic nanosensor for quantitative detection of acetylcholine (ACh) in the peripheral nervous system of living mice. ACh nanosensors consist of DNA as a scaffold, acetylcholinesterase as a recognition component, pH-sensitive fluorophores as signal generators, and α-bungarotoxin as a targeting moiety. We demonstrate the utility of the nanosensors in the submandibular ganglia of living mice to sensitively detect ACh ranging from 0.228 to 358 µM. In addition, the sensor response upon electrical stimulation of the efferent nerve is dose dependent, reversible, and we observe a reduction of ∼76% in sensor signal upon pharmacological inhibition of ACh release. Equipped with an advanced imaging processing tool, we further spatially resolve ACh signal propagation on the tissue level. Our platform enables sensitive measurement and mapping of ACh transmission in the peripheral nervous system.


Assuntos
Acetilcolina/metabolismo , Técnicas Biossensoriais/métodos , Gânglios Parassimpáticos/metabolismo , Nanotecnologia/métodos , Acetilcolina/análise , Acetilcolinesterase/química , Acetilcolinesterase/metabolismo , Animais , Bungarotoxinas/farmacologia , Carbocianinas/química , Antagonistas Colinérgicos/farmacologia , DNA/química , Feminino , Corantes Fluorescentes/química , Gânglios Parassimpáticos/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Receptores Colinérgicos/metabolismo
7.
Mikrochim Acta ; 191(9): 525, 2024 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120793

RESUMO

A dual-emission ratiometric fluorescence sensor (CDs@CdTe@MIP) with a self-calibration function was successfully constructed for AMO detection. In the CDs@CdTe@MIP system, non-imprinted polymer-coated CDs and molecule-imprinted polymer-coated CdTe quantum dots were used as the reference signal and response elements, respectively. The added AMO quenched the fluorescence of the CdTe quantum dots, whereas the fluorescence intensity of the CDs remained almost unchanged. The AMO concentration was monitored using the fluorescence intensity ratio (log(I647/I465)0/(I647/I465)) to reduce interference from the testing environment. The sensor with a low detection limit of 0.15 µg/L enabled detection of the AMO concentration within 6 min. The ratiometric fluorescence sensor was used to detect AMO in spiked pork samples; it exhibited a high recovery efficiency and relative standard deviation (RSD) of 97.94-103.70% and 3.77-4.37%, respectively. The proposed highly sensitive and selective platform opens avenues for sensitive, reliable, and rapid determination of pharmaceuticals in the environment and food safety monitoring using ratiometric sensors.


Assuntos
Amoxicilina , Compostos de Cádmio , Limite de Detecção , Impressão Molecular , Pontos Quânticos , Espectrometria de Fluorescência , Telúrio , Pontos Quânticos/química , Compostos de Cádmio/química , Telúrio/química , Espectrometria de Fluorescência/métodos , Amoxicilina/análise , Amoxicilina/química , Corantes Fluorescentes/química , Sulfetos/química , Animais , Contaminação de Alimentos/análise , Polímeros Molecularmente Impressos/química , Suínos
8.
Mikrochim Acta ; 191(9): 551, 2024 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-39167235

RESUMO

Photon-upconversion nanoparticles (UCNP) have already been established as labels for affinity assays in analog and digital formats. Here, advanced, or smart, systems based on UCNPs coated with active shells, fluorescent dyes, and metal and semiconductor nanoparticles participating in energy transfer reactions are reviewed. In addition, switching elements can be embedded in such assemblies and provide temporal and spatial control of action, which is important for intracellular imaging and monitoring activities. Demonstration and critical comments on representative approaches demonstrating the progress in the use of such UCNPs in bioanalytical assays, imaging, and monitoring of target molecules in cells are reported, including particular examples in the field of cancer theranostics.


Assuntos
Nanopartículas , Fótons , Humanos , Nanopartículas/química , Corantes Fluorescentes/química , Animais , Neoplasias/diagnóstico por imagem , Neoplasias/diagnóstico , Imagem Óptica
9.
Mikrochim Acta ; 191(10): 586, 2024 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-39251454

RESUMO

A unique method for determining chlorophyll content in microalgae is devised employing a gold interdigitated electrode (G-IDE) with a 10-µm gap, augmented by a nano-molecularly imprinted polymer (nano-MIP) and a titanium dioxide/multiwalled carbon nanotube (TiO2/MWCNT) nanocomposite. The nano-MIP, produced using chlorophyll template voids, successfully trapped chlorophyll, while the TiO2/MWCNT nanocomposite, synthesized by the sol-gel technique, exhibited a consistent distribution and anatase crystalline structure. The rebinding of procured chlorophyll powder, which was used as a template for nano-MIP synthesis, was identified with a high determination coefficient (R2 = 0.9857). By combining the TiO2/MWCNT nanocomposite with nano-MIP, the G-IDE sensing method achieved a slightly better R2 value of 0.9892 for detecting chlorophyll in microalgae. The presented G-IDE sensor showed a significant threefold enhancement in chlorophyll detection compared with commercially available chlorophyll powder. It had a detection limit of 0.917 mL (v/v) and a linear range that spanned from 10-6 to 1 mL. The effectiveness of the sensor in detecting chlorophyll in microalgae was confirmed through validation of its repeatability and reusability.


Assuntos
Clorofila , Técnicas Eletroquímicas , Eletrodos , Ouro , Microalgas , Polímeros Molecularmente Impressos , Nanotubos de Carbono , Titânio , Titânio/química , Nanotubos de Carbono/química , Ouro/química , Clorofila/química , Clorofila/análise , Microalgas/química , Polímeros Molecularmente Impressos/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Limite de Detecção , Impressão Molecular
10.
Mikrochim Acta ; 191(6): 299, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709371

RESUMO

Gold nanoclusters are a smart platform for sensing potassium ions (K+). They have been synthesized using bovine serum albumin (BSA) and valinomycin (Val) to protect and cap the nanoclusters. The nanoclusters (Val-AuNCs) produced have a red emission at 616 nm under excitation with 470 nm. In the presence of K+, the valinomycin polar groups switch to the molecule's interior by complexing with K+, forming a bracelet structure, and being surrounded by the hydrophobic exterior conformation. This structure allows a proposed fluorometric method for detecting K+ by switching between the Val-AuNCs' hydrophilicity and hydrophobicity, which induces the aggregation of gold nanoclusters. As a result, significant quenching is seen in fluorescence after adding K+. The quenching in fluorescence in the presence of K+ is attributed to the aggregation mechanism. This sensing technique provides a highly precise and selective sensing method for K+ in the range 0.78 to 8 µM with LOD equal to 233 nM. The selectivity of Val-AuNCs toward K+ ions was investigated compared to other ions. Furthermore, the Val-AuNCs have novel possibilities as favorable sensor candidates for various imaging applications. Our detection technique was validated by determining K+ ions in postmortem vitreous humor samples, which yielded promising results.


Assuntos
Corantes Fluorescentes , Ouro , Nanopartículas Metálicas , Potássio , Soroalbumina Bovina , Valinomicina , Ouro/química , Valinomicina/química , Potássio/análise , Potássio/química , Nanopartículas Metálicas/química , Soroalbumina Bovina/química , Corantes Fluorescentes/química , Espectrometria de Fluorescência/métodos , Limite de Detecção , Animais , Interações Hidrofóbicas e Hidrofílicas , Bovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA