Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.260
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37874971

RESUMO

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Assuntos
Endocardite Bacteriana , Endocardite , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Trombose , Adulto , Humanos , Cateterismo Cardíaco/efeitos adversos , Endocardite/epidemiologia , Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/epidemiologia , Insuficiência da Valva Pulmonar/cirurgia , Sistema de Registros , Estudos Retrospectivos , Trombose/etiologia , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 103(4): 612-617, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419395

RESUMO

While newer self-expanding pulmonic valves were primarily designed for larger right ventricular outflow tracks, there are instances where even larger anatomies cannot accommodate these devices. In this report, we describe the successful implantation of two Harmony™ valves in bilateral branch pulmonary arteries after exhausting other options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco
3.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419402

RESUMO

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Pulmonar , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Ásia , Catéteres
4.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
5.
Artigo em Inglês | MEDLINE | ID: mdl-39033329

RESUMO

BACKGROUND: Patients with d-transposition of the great arteries (d-TGA) who have undergone an arterial switch operation (ASO) can develop right ventricular outflow tract (RVOT) dysfunction with pulmonary regurgitation (PR) or stenosis. In these patients, treatment may include transcatheter pulmonary valve replacement (TPVR). Coronary compression is a contraindication occurring in 5% of typical TPVR cases. After ASO, there are various anatomical considerations that can confound TPVR, including potential coronary artery compression. Our goal is to understand feasibility of TPVR in patients following ASO. METHODS: This was a retrospective multicenter cohort study of patients with RVOT dysfunction after ASO who underwent cardiac catheterization with intention to perform TPVR from 2008 to 2020. RESULTS: Across nine centers, 33 patients met inclusion criteria. TPVR was successful in 22 patients (66%), 19 receiving a Melody valve and 3 a SAPIEN valve. RVOT stenosis in isolation or with PR dictated need for TPVR in nearly all patients. One serious adverse event occurred with valve embolization. After TPVR, the RVOT peak gradient decreased from 43 to 9 mm Hg (p < 0.001); PR was trivial/none in all but one patient, in whom it was mild. Coronary compression prohibiting TPVR occurred in eight patients (24%) and two patients (6%) had severe aortic regurgitation from aortic root deformation precluding TPVR. Seven patients underwent RVOT reintervention with a median of 5.3 years post-TPVR. CONCLUSIONS: TPVR in patients with d-TGA after ASO is feasible, but in this cohort, coronary compression or aortic root distortion precluded TPVR in one-third of patients. The rate of RVOT reintervention after TPVR was higher in this cohort of ASO patients that in prior studies.

6.
Catheter Cardiovasc Interv ; 104(2): 256-263, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38967206

RESUMO

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Masculino , Feminino , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Adulto , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Adulto Jovem , Angiografia por Tomografia Computadorizada , Adolescente , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X
7.
Catheter Cardiovasc Interv ; 103(4): 587-596, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38341624

RESUMO

BACKGROUND: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies. METHODS: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers. RESULTS: Pulsta valve implantation was successful in 179 out of 182 patients (98.4%) with an average age of 26.7 ± 11.0 years. The median follow-up duration was 29 months. Baseline assessments revealed enlarged right ventricle (RV) volume (mean indexed RV end-diastolic volume: 163.1 (interquartile range, IQR: 152.0-180.3 mL/m²), which significantly decreased to 123.6(IQR: 106.6-137.5 mL/m2  after 1 year. The main PA types were classified as pyramidal (3.8%), straight (38.5%), reverse pyramidal (13.2%), convex (26.4%), and concave (18.1%) shapes. Pulsta valve placement was adapted, with distal main PA for pyramidal shapes and proximal or mid-PA for reverse pyramidal shapes. Two patients experienced Pulsta valve embolization to RV, requiring surgical removal, and one patient encountered valve migration to the distal main PA, necessitating surgical fixation. CONCLUSIONS: Customized valve insertion sites are pivotal in self-expandable PPVI considering diverse native RVOT shape. The rather soft and compact structure of the Pulsta valve has characteristics to are adaptable to diverse native RVOT geometries.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adolescente , Adulto Jovem , Adulto , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ventrículos do Coração , Estudos Retrospectivos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Resultado do Tratamento , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Cateterismo Cardíaco
8.
Catheter Cardiovasc Interv ; 103(3): 455-463, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38204358

RESUMO

This manuscript describes the feasibility and approach to the assessment and performance of transcatheter pulmonary valve replacement (tPVR) in patients with surgically-created "double-barrel" right ventricular outflow tracts (RVOT). Patients with tetralogy of Fallot may have coronary anomalies which prohibit the performance of traditional tetralogy of Fallot repair. In certain cases, this may necessitate the placement of a right ventricle to pulmonary artery conduit in addition to the native RVOT, which is left in situ, creating so-called "double-barrel" RVOTs. When these patients develop RVOT dysfunction later in life, they would typically be referred for reoperation due to concerns for risk of coronary compression associated with a transcatheter approach. However, whether a transcatheter approach with valve replacement in the native RVOT is feasible or safe is unknown. This was a retrospective review of patients with a surgically created "double-barrel" RVOTs who underwent cardiac catheterization for assessment of tPVR at Boston Children's Hospital. From July 2012 to July 2022, there were four patients with "double-barrel" RVOTs who underwent assessment for tPVR. The age at catheterization ranged between 22 and 39 years. In three out of four patients, coronary compression testing was negative. These three patients had successful tPVR in the native RVOT. At follow up, all three patients were free of greater than mild regurgitation by echocardiogram and had a maximum instantaneous gradient across the RVOT ranging between 20 and 33 mmHg. Performance of tPVR in patients with surgically created "double-barrel" RVOTs is feasible. The safety of this procedure depends crucially on coronary artery assessment at all stages.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Criança , Humanos , Adulto Jovem , Adulto , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Ventrículos do Coração/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia
9.
Catheter Cardiovasc Interv ; 103(4): 597-606, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38440908

RESUMO

BACKGROUND: Current heart valve implants entail major disadvantages in the treatment for younger patients or those with congenital heart defects. AIM: Evaluation of novel transcatheter pulmonary valve implant made from autologous pericardium with natural crosslinking agent in an in vitro setup and in vivo animal model METHODS: Valves were tested in a pulse duplicator according to ISO-standard 5840. For in vivo studies computer tomography was performed to measure sheep's native pulmonary valve dimensions. Pericardium was harvested by thoracotomy, personalized implants were manufactured and deployed in pulmonary valve position of the same sheep. Every 3 months implant functionality was evaluated by intracardiac echocardiography, intracardiac pressure measurements and cardiac magnetic resonance imaging (cMRI). Implants were explanted for macroscopic and histological examination. RESULTS: In vitro experiments showed compliance with regulatory requirements in terms of valve opening and insufficiency. Five sheep successfully received an autologous valve implant. Two animals had to be euthanized due to trauma sustained in the stable. Long-term valve function was excellent in three out of four animals with median implant cMRI regurgitation fraction of 9% (n = 4) at 3 months, 8% (n = 3) at 6, 8% (n = 3) at 9, 12% (n = 3) at 13, 8% (n = 2) at 17% and 8% (n = 2) at 20.5 months after implantation. Despite good adherence to neighboring tissue and endothelization, histological assessment revealed some signs of degeneration. CONCLUSION: Transcatheter pulmonary valve implants showed promising function for up to 20.5 months encouraging research to further improve this approach.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Humanos , Adulto , Animais , Ovinos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valvas Cardíacas/cirurgia , Modelos Animais
10.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872098

RESUMO

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Valva Pulmonar , Recuperação de Função Fisiológica , Humanos , Masculino , Criança , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Adolescente , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Fatores de Tempo , Adulto , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Bioprótese , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sudeste Asiático
11.
BMC Cardiovasc Disord ; 24(1): 15, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172687

RESUMO

BACKGROUND: Patients with repaired Tetralogy of Fallot (rTOF) often develop pulmonary regurgitation (PR) and right ventricle (RV) dysfunction, experiencing increased mortality and morbidity rates in adulthood. Pulmonary valve replacement (PVR) timing to address PR is controversial. Cardiac Magnetic Resonance (CMR) is the gold standard for morpho-functional evaluation of complex cardiopathies. This study aims to identify CMR parameters predictive of adverse outcomes to help defining the best therapeutic management of rTOF patients. METHODS: 130 rTOF patients who underwent CMR (2006-2019) were enrolled in this retrospective single-center study. CMR, clinical, ECG and exercise data were analyzed. Univariate and multivariate analyses identified clinical and CMR parameters predictive of adverse outcomes both individually (e.g., death, arrhythmias, heart failure (HF), pharmacological therapy, QRS ≥ 160ms) and as composite outcome. RESULTS: Univariate analysis confirmed RV volumes and RV ejection fraction corrected for PR as adverse outcome predictors and identified interesting correlations: pulmonary artery bifurcation geometry and abnormal interventricular septum (IVS) motion with arrhythmias (p < .001; p = .037), HF (p = .049; p = .005), composite outcome (p = .039; p = .009); right atrium (RA) dimensions with the composite outcome and the outcomes individually (p < .001). The best predictive models by multivariate analysis included sex (male), RV and RA dilation for QRS ≥ 160ms, time form repair to CMR, age at TOF repair and IVS fibrosis for pharmacological therapy. CONCLUSIONS: Besides RV volumes, new adverse prognostic factors could guide rTOF therapeutic management: pulmonary arteries morphology, abnormal IVS motion, RV dysfunction, RA dilation. Perspective multicentric evaluation is needed to specify their effective role.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Masculino , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Espectroscopia de Ressonância Magnética , Função Ventricular Direita , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
12.
Echocardiography ; 41(2): e15765, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38341768

RESUMO

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Assuntos
Insuficiência da Valva Pulmonar , Estenose da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Deformação Longitudinal Global , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Direita , Estenose da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/complicações , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem
13.
Pediatr Cardiol ; 45(2): 446-451, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37955720

RESUMO

Absent pulmonary valve with tricuspid atresia or tricuspid stenosis (APV-TA/TS) is an extremely rare congenital heart defect associated with significant morbidity and mortality. Compared to Tetralogy of Fallot with Absent Pulmonary Valve Syndrome, branch pulmonary arteries are not typically significantly dilated. We present the case of a newborn male prenatally diagnosed APV-TA with intact ventricular septum (IVS) and nearly discontinuous branch pulmonary arteries, the surgical strategy employed, and the salient hemodynamic factors considered in the medical decision-making.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Valva Pulmonar , Atresia Tricúspide , Septo Interventricular , Recém-Nascido , Masculino , Humanos , Atresia Tricúspide/diagnóstico por imagem , Atresia Tricúspide/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/cirurgia
14.
Pediatr Cardiol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39043954

RESUMO

Candidacy for transcatheter pulmonary valve replacement utilizing newer valve platforms is aided by industry-driven fit analyses. We report augmentation of this decision-making process by visualization of 4-dimensional cine imaging of patient-specific right ventricular outflow tract anatomy and a virtual valve model within a virtual reality platform.

15.
Pediatr Cardiol ; 45(3): 570-579, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38296854

RESUMO

Transcatheter pulmonary valve implantation (TPVI) is a surgical alternative for correcting dysfunctional right ventricular outflow tract in previously operated patients. MyVal transcatheter heart valve (THV) (Meril Life Sciences, India), a new transcatheter valve designed for aortic position has recently been reported to be implanted in pulmonary position. Myval transcatheter valve were implanted in patients with stenosed dysfunctional conduits, severe regurgitation from transannular patch or dysfunctional surgical pulmonary valves (Bioprosthesis). Procedural details and post-TPVI follow-up were analysed. Myval TPVI was used in Fifty three patients with median age of 15 years (IQR 12-19.5 years). Almost sixty percent of the patients were male, with a median weight of 50 kg (31-63 kg). Prestenting was used in more than 80 percent of patients (n = 45 patients), while 6 patients had a prior surgical valve implantation. After Myval TPVI implantation, the peak instantaneous gradient across the RVOT decreased from a median of 23.5 mmHg (IQR 10-53 mmHg) pre-procedure to 10 mmHg (IQR 5-16 mmHg) post-procedure. The median fluoroscopy time for the procedure was 35 min (IQR 23.5-44 min). The large sizes-mainly the 29-mm and 32 mm Myval (Navigator, Meril Life Sciences Pvt Ltd, India), were the most used size in 40% (n = 22) of the cases each. The median contrast volume used during the procedure was 247 mL (IQR 120-300 mL). Patients were followed for a median period of 360 days (IQR 164-525 days). At the last clinic follow-up, there was no tricuspid valve regurgitation. Moderate neo-pulmonary valve regurgitation was reported in three cases. Early experience of TPVI with MyVal is encouraging with procedural success in all patients and acceptable mid-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Masculino , Criança , Adolescente , Adulto Jovem , Adulto , Feminino , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Desenho de Prótese , Cateterismo Cardíaco/métodos
16.
Pediatr Cardiol ; 45(3): 588-590, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38315220

RESUMO

In this review, we provide a brief description of recently published articles addressing topics relevant to pediatric cardiologists. Our hope is to provide a summary of the latest articles published recently in other journals in our field. The articles address (1) A new index for prenatal diagnosis of total anomalous pulmonary venous return, (2) Outcomes of patients with Tetralogy of Fallot after pulmonary valve replacement (PVR), and (3) Short-term outcomes of the self expanding Harmony valve for transcatheter PVR.

17.
Pediatr Cardiol ; 45(4): 722-728, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38411710

RESUMO

Pulmonary balloon valvuloplasty (PBV) is the treatment of choice for subjects with isolated pulmonary valve stenosis (IPS). The purpose of this study was to define fetal echocardiographic features associated with an inpatient PBV prior to newborn hospital discharge and characterize resource utilization of IPS fetuses among participating centers. Six center, retrospective case series of singleton fetuses identified between 2010 and 2020 with IPS. Third-trimester echocardiogram data was compared with postnatal data, included pulmonary valve Doppler velocities, pulmonary valve insufficiency and ductus arteriosus flow direction. Comparison between subjects who underwent inpatient PBV during their newborn hospital admission versus those infants referred for outpatient PBV after initial hospital discharge. We analyzed data by logistic regression, student t test and Chi-Square testing with a p value of ≤ 0.05 considered statistically significant. Forty-nine IPS fetuses were identified. Thirty-eight (78%) underwent inpatient PBV at 5 (range 1-58) days and 11 (22%) underwent outpatient PBV at 51.8 (11-174) days. Newborns requiring an inpatient PBV were more likely to have one or more characteristics on 3rd-trimester fetal echocardiogram: left to right or bidirectional ductus arteriosus flow (61% vs 0%), and/or a peak pulmonary valve velocity > 3.0 m/s (odds ratio 16.9, 95% confidence interval 3.02-94.17) with a sensitivity of 90.4% and specificity of 97.7%. Ductus arteriosus flow direction and pulmonary valve peak velocity in the 3rd trimester can successfully predict the need for newborn inpatient PBV. We speculate these findings may be useful in choosing delivery site for the pregnancy complicated by fetal IPS.


Assuntos
Valvuloplastia com Balão , Permeabilidade do Canal Arterial , Canal Arterial , Estenose da Valva Pulmonar , Lactente , Feminino , Gravidez , Humanos , Recém-Nascido , Estudos Retrospectivos , Ecocardiografia , Terceiro Trimestre da Gravidez , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Ultrassonografia Pré-Natal
18.
Cardiol Young ; : 1-3, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38528794

RESUMO

We report the case of a 9-year-old male with severe congenital pulmonary valve stenosis referred to our centre for percutaneous valvotomy. On admission, trans-thoracic echocardiogram confirmed a unicuspid pulmonary valve with a peak/mean pulmonary valve gradient of 91/53 mmHg and a pulmonary annulus of 13.8 mm (-0.8 Z Score). It also showed an enlarged RV (RV/LV ratio 0,9). During cardiac catheterisation, an additional atrial septal defect (secundum) with significant left to right shunt (Qp/Qs > 2) was diagnosed, which was not amenable to percutaneous closure. The patient was referred for surgical repair.The atrial septal defect was closed by a direct running suture. The repair of the unicuspid valve consisted in bicuspidisation by a large commissurotomy to the left anterior wall of the pulmonary artery. The neo-commissure was created with two separate patches of autologous pericardium secured to the wall of the pulmonary root. The adjustment of the effective height of the pulmonary valve leaflets was done by trimming the patches and a triangular plication of the newly created posterior leaflet. Perioperative echocardiogram showed a peak gradient of 15 mm Hg and trivial pulmonary regurgitation. The total cross-clamp time was 92 min and the bypass time 123 min with a favourable evolution after the surgery.The particularity of the case is represented by the complexity of the bicuspidisation procedure. Using this technique, a tailored approach is needed for every patient.

19.
Cardiol Young ; 34(4): 865-869, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37921218

RESUMO

BACKGROUND AND AIM: Pulmonary regurgitation is the most common complication in repaired tetralogy of Fallot patients. Severe chronic pulmonary regurgitation can be tolerated for decades, but if not treated, it can progress to symptomatic, irreversible right ventricular dilatation and dysfunction. We investigated clinical associations with pulmonary valve replacement among patients with significative pulmonary regurgitation and how interventional developments can change their management. METHODS: All adult patients with repaired tetralogy of Fallot who were followed at an adult CHD Clinic at a single centre from 1980 to 2022 were included on their first outpatient visit. Follow-up was estimated from the time of correction surgery until one of the following events occurred first: pulmonary valve replacement, death, loss to follow-up or conclusion of the study. RESULTS: We included 221 patients (116 males) with a median age of 19 (18-25). At a median age of 33 (10) years old, 114 (51%) patients presented significant pulmonary regurgitation. Among patients with significant pulmonary regurgitation, pulmonary valve replacement was associated with male gender, older age at surgical repair, and longer QRS duration in adulthood. Pulmonary valve replacement was performed in 50 patients, including four transcatheter pulmonary valve implantations, at a median age of 34 (14) years. CONCLUSION: Pulmonary regurgitation affects a large percentage of tetralogy of Fallot adult patients, requiring a long-term clinical and imaging follow-up. Sex, age at surgical repair and longer QRS are associated with the need of PVR among patients with significative pulmonary regurgitation. Clinical practice and current literature support TPVI as the future gold standard intervention.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Adulto , Humanos , Masculino , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
20.
Cardiol Young ; 34(1): 171-177, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37309189

RESUMO

INTRODUCTION: Transcatheter pulmonary valve replacement serves as a successful alternative to surgical replacement of a right ventricle to pulmonary artery conduit. Guidelines for recommending transcatheter pulmonary valve replacement depend on MRI right ventricular volumes, which have been correlated to the echocardiographic measure of right ventricular annular tilt. We aim to assess whether right ventricular annular tilt can be a clinically useful alternative tool in the acute and long-term periods after transcatheter pulmonary valve replacement to assess right ventricular health. METHODS: We reviewed 70 patients who underwent transcatheter pulmonary valve replacement at a single institution. Echocardiographic measurements were obtained prior to transcatheter pulmonary valve replacement, immediately after transcatheter pulmonary valve replacement, and within 6 months to 1 year after transcatheter pulmonary valve replacement. Right ventricular annular tilt measures the angle of the tricuspid valve plane relative to the mitral valve plane at end-diastole in the apical four-chamber view. Right ventricular fractional area change, right ventricular systolic strain, tissue Doppler velocity, and tricuspid annular plane systolic excursion Z-scores were obtained using published methods. RESULTS: Right ventricular annular tilt decreased significantly immediately after transcatheter pulmonary valve replacement (p = 0.0004), and this reduction in right ventricular volume persisted at the mid-term follow-up (p < 0.0001). Fractional area change did not change significantly after transcatheter pulmonary valve replacement while right ventricular global strain improved at mid-term follow-up despite no significant difference immediately after transcatheter pulmonary valve replacement. CONCLUSIONS: Right ventricular annular tilt decreases both immediately after transcatheter pulmonary valve replacement and at mid-term follow-up. Right ventricular strain also improved after transcatheter pulmonary valve replacement, corresponding to the improved volume load. Right ventricular annular tilt can be considered as an additional echocardiographic factor to assess right ventricular volume and remodeling after transcatheter pulmonary valve replacement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Pulmonar , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Ecocardiografia , Função Ventricular Direita , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA