Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(2): e14270, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38240466

RESUMO

With the ever-increasing use of computed tomography (CT), concerns about its radiation dose have become a significant public issue. To address the need for radiation dose reduction, CT denoising methods have been widely investigated and applied in low-dose CT images. Numerous noise reduction algorithms have emerged, such as iterative reconstruction and most recently, deep learning (DL)-based approaches. Given the rapid advancements in Artificial Intelligence techniques, we recognize the need for a comprehensive review that emphasizes the most recently developed methods. Hence, we have performed a thorough analysis of existing literature to provide such a review. Beyond directly comparing the performance, we focus on pivotal aspects, including model training, validation, testing, generalizability, vulnerability, and evaluation methods. This review is expected to raise awareness of the various facets involved in CT image denoising and the specific challenges in developing DL-based models.


Assuntos
Inteligência Artificial , Redução da Medicação , Humanos , Melhoria de Qualidade , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos
2.
AJR Am J Roentgenol ; 220(4): 580-589, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36287620

RESUMO

Photon-counting detector (PCD) CT represents the most recent generational advance in CT technology. PCD CT has the potential to reduce image noise, improve spatial resolution and contrast resolution, and provide multispectral capability, all of which may be achieved with an overall decrease in the radiation dose. These effects may be used to reduce the iodinated contrast media dose and potentially obtain multiphase images through a single-acquisition technique. The benefits of PCD CT have previously been shown primarily in phantoms and adult patients. This article describes the application of PCD CT in children, as illustrated by clinical examples from a commercially available PCD CT system.


Assuntos
Pediatria , Radiologia , Tomografia Computadorizada por Raios X , Pediatria/instrumentação , Pediatria/métodos , Radiologia/instrumentação , Radiologia/métodos , Humanos , Criança , Imagens de Fantasmas
3.
Skeletal Radiol ; 52(9): 1651-1659, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36971838

RESUMO

OBJECTIVE: The feasibility of low-dose photon-counting detector (PCD) CT to measure alpha and acetabular version angles of femoroacetabular impingement (FAI). MATERIAL AND METHODS: FAI patients undergoing an energy-integrating detector (EID) CT underwent an IRB-approved prospective ultra-high-resolution (UHR) PCD-CT between 5/2021 and 12/2021. PCD-CT was dose-matched to the EID-CT or acquired at 50% dose. Simulated 50% dose EID-CT images were generated. Two radiologists evaluated randomized EID-CT and PCD-CT images and measured alpha and acetabular version angles on axial image slices. Image quality (noise, artifacts, and visualization of cortex) and confidence in non-FAI pathology were rated on a 4-point scale (3 = adequate). Preference tests of standard dose PCD-CT, 50% dose PCD-CT, and 50% dose EID-CT relative to standard dose EID-CT were performed using Wilcoxon Rank test. RESULTS: 20 patients underwent standard dose EID-CT (~ CTDIvol, 4.5 mGy); 10 patients, standard dose PCD-CT (4.0 mGy); 10 patients, 50% PCD-CT (2.6 mGy). Standard dose EID-CT images were scored as adequate for diagnostic task in all categories (range 2.8-3.0). Standard dose PCD-CT images scored higher than the reference in all categories (range 3.5-4, p < 0.0033). Half-dose PCD-CT images also scored higher for noise and cortex visualization (p < 0.0033) and equivalent for artifacts and visualization of non-FAI pathology. Finally, simulated 50% EID-CT images scored lower in all categories (range 1.8-2.4, p < 0.0033). CONCLUSIONS: Dose-matched PCD-CT is superior to EID-CT for alpha angle and acetabular version measurement in the work up of FAI. UHR-PCD-CT enables 50% radiation dose reduction compared to EID while remaining adequate for the imaging task.


Assuntos
Impacto Femoroacetabular , Humanos , Impacto Femoroacetabular/diagnóstico por imagem , Estudos Prospectivos , Estudos de Viabilidade , Fótons , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação
4.
J Digit Imaging ; 36(4): 1578-1587, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36944812

RESUMO

The purpose is to evaluate whether deep learning-based denoising (DLD) algorithm provides sufficient image quality for abdominal computed tomography (CT) with a 30% reduction in radiation dose, compared to standard-dose CT reconstructed with conventional hybrid iterative reconstruction (IR). The subjects consisted of 50 patients who underwent abdominal CT with standard dose and reconstructed with hybrid IR (ASiR-V50%) and another 50 patients who underwent abdominal CT with approximately 30% less dose and reconstructed with ASiR-V50% and DLD at low-, medium- and high-strength (DLD-L, DLD-M and DLD-H, respectively). The standard deviation of attenuation in liver parenchyma was measured as image noise. Contrast-to-noise ratio (CNR) for portal vein on portal venous phase was calculated. Lesion conspicuity in 23 abdominal solid mass on the reduced-dose CT was rated on a 5-point scale: 0 (best) to -4 (markedly inferior). Compared with hybrid IR of standard-dose CT, DLD-H of reduced-dose CT provided significantly lower image noise (portal phase: 9.0 (interquartile range, 8.7-9.4) HU vs 12.0 (11.4-12.7) HU, P < 0.0001) and significantly higher CNR (median, 5.8 (4.4-7.4) vs 4.3 (3.3-5.3), P = 0.0019). As for DLD-M of reduced-dose CT, no significant difference was found in image noise and CNR compared to hybrid IR of standard-dose CT (P > 0.99). Lesion conspicuity scores for DLD-H and DLD-M were significantly better than hybrid IR (P < 0.05). Dynamic contrast-enhanced abdominal CT acquired with approximately 30% lower radiation dose and generated with the DLD algorithm exhibit lower image noise and higher CNR compared to standard-dose CT with hybrid IR.


Assuntos
Aprendizado Profundo , Humanos , Redução da Medicação , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos
5.
J Stroke Cerebrovasc Dis ; 31(12): 106844, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36323170

RESUMO

OBJECTIVES: Integration of CT perfusion (CTP) with requisite non-contrast CT and CT angiography (CTA) stroke imaging may allow efficient stroke lesion volume measurement. Using surrogate images from CTP, we simulated the feasibility of using multiphase CTA (mCTA) to generate perfusion maps and assess target mismatch profiles. MATERIALS AND METHODS: Patients with acute ischemic stroke who received admission CTP were included in this study. Four CTP images (surrogate mCTA, one pre-contrast and three post-contrast, starting at the arterial peak then at 8 s intervals) were selected according to the CTP arterial time-density curve to simulate non-contrast CT and mCTA images. Cerebral blood flow (CBF) and Tmax maps were calculated using the same model-based deconvolution algorithm for the standard CTP and surrogate mCTA studies. Infarct and penumbra were delineated with CBF < 20% and Tmax > 6 s threshold, respectively. Classification accuracy of surrogate mCTA target mismatch (infarct <70 ml; penumbra ≥15 ml; mismatch ratio ≥1.8) with respect to standard CTP was assessed. Agreement between infarct and penumbra volumes from standard CTP and surrogate mCTA maps were evaluated by Bland-Altman analysis. RESULTS: Of 34 included patients, 28 had target mismatch and 6 did not by standard CTP. Accuracy of classifying target mismatch profiles with surrogate mCTA was 79% with respect to that from standard CTP. Mean  ±  standard deviation of differences (standard CTP minus surrogate mCTA) of infarct and penumbra volumes were 9.8 ± 14.8 ml and 20.1 ± 45.4 ml, respectively. CONCLUSIONS: Surrogate mCTA ischemic lesion volumes agreed with those from standard CTP and may be an efficient alternative when CTP is not practical.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/diagnóstico por imagem , Angiografia Cerebral/métodos , Circulação Cerebrovascular , Angiografia por Tomografia Computadorizada/métodos , Estudos de Viabilidade , Infarto , Perfusão , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
6.
Can Assoc Radiol J ; 73(1): 203-213, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33781098

RESUMO

Acute pulmonary embolism (APE) is a well-recognized cause of circulatory system compromise and even demise which can frequently present a diagnostic challenge for the physician. The diagnostic challenge is primarily due to the frequency of indeterminate presentations as well as several other conditions which can have a similar clinical presentation. This often obliges the physician to establish a firm diagnosis due to the potentially serious outcomes related to this disease. Computed tomography pulmonary angiography (CTPA) has increasingly cemented its role as the primary investigation tool in this clinical context and is widely accepted as the standard of care due to several desired attributes which include great accuracy, accessibility, rapid turn-around time and the ability to suggest an alternate diagnosis when APE is not the culprit. In Part 1 of this guidance document, a series of up-to-date recommendations are provided to the reader pertaining to CTPA protocol optimization (including scan range, radiation and intravenous contrast dose), safety measures including the departure from breast and gonadal shielding, population-specific scenarios (pregnancy and early post-partum) and consideration of alternate diagnostic techniques when clinically deemed appropriate.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Segurança do Paciente , Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Canadá , Humanos , Artéria Pulmonar/diagnóstico por imagem , Radiologistas , Sociedades Médicas
7.
J Nucl Cardiol ; 28(4): 1536-1544, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31485963

RESUMO

BACKGROUND: Clinical practice shows degrading image quality in heavier patients who undergo myocardial perfusion imaging (MPI) with Rubidium-82 (Rb-82) PET when using a fixed tracer activity. Our aim was to derive and validate a patient-specific activity protocol resulting in a constant image quality in PET MPI. METHODS: We included 251 patients who underwent rest MPI with Rb-82 PET (Discovery 670, GE Healthcare). 132 patients were included retrospectively and were scanned using a fixed activity of 740 MBq. The total number of measured prompts was normalized to activity and correlated to body weight, mass per body length and body mass index to find the best predicting parameter. Next, a patient-specific activity was derived and subsequently validated in 119 additional patients. Image quality was scored by three experts on a four-point scale. RESULTS: Both image quality and prompts decreased in heavier patients when using a fixed activity (p < .005). Body weight was used to derive a new activity formula: Activity = 8.3 MBq/kg. When applying this formula, both measured prompts and scored image quality became independent of body weight (p > .60). CONCLUSION: Administrating a Rb-82 activity that linearly depends on body weight resulted in a constant image quality across all patients and is recommended.


Assuntos
Peso Corporal , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Radioisótopos de Rubídio/farmacocinética , Idoso , Índice de Massa Corporal , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
J Appl Clin Med Phys ; 22(2): 194-202, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33338314

RESUMO

It is important to employ radiation dose reduction techniques in pediatric computed tomography (CT) to reduce potential risks of radiation-induced malignancy. Automatic tube potential (kV) selection tools have been developed and become available on many CT scanners, which select the optimum kV based on the patient size and clinical task to improve the radiation dose efficiency. However, its use in pediatric CT has been mostly empirical, following manufacturer's default recommendation without solid demonstration for quality improvement. This study aimed to implement an automatic tube potential tool (CAREkV, Siemens Healthcare) into routine pediatric CT practice, using the "Plan-Do-Study-Act" quality improvement process, in place of an existing kV/mAs technique chart. The design of this quality improvement project involved Plan-Do-Study-Act stages. Plan and Do stages identified the criteria for optimal automatic kV selection; a range of phantoms representing typical pediatric groups were scanned on a dual-source 128-slice scanner using a fast-pitch scanning mode. The identified CAREkV settings were implemented into the CT protocol and evaluated after a 6-month period. In the Study stage, an objective evaluation of the image metrics and radiation dose for two similar patient cohorts using CAREkV and the technique-chart, respectively, were compared. The kV selected, image quality and radiation dose determined by CAREkV were comparable to those obtained while using the technique-chart. The CAREkV was successfully implemented into our pediatric abdominopelvic CT practice. By utilizing the "PDSA" process optimal image quality and radiation dose reduction were achieved with an automatic kV selection tool to improve CT workflow.


Assuntos
Tomografia Computadorizada por Raios X , Criança , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomógrafos Computadorizados , Fluxo de Trabalho
9.
J Xray Sci Technol ; 29(3): 517-527, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33814483

RESUMO

OBJECTIVE: To demonstrate the ability of achieving low dose and high-quality head CT images for children with acute head trauma using 100 kVp and adaptive statistical iterative reconstruction (ASIR-V) algorithm in single rotation on a 16 cm wide-detector system. MATERIALS AND METHODS: We retrospectively analyzed the CT dose index (CTDI) and image quality of 104 children aged 0-6 years with acute head trauma (1 hour -3 days) in two groups: Group 1(n = 50) on a 256-row CT with single rotation at a reduced-dose of 100 kVp/240 mA and reconstructed using ASIR-V at 70%level; Group 2(n = 54) on a 64-row CT with multiple rotations at a standard dose of 120 kVp/ 180mA and reconstructed using a conventional filtered back-projection (FBP). Both groups used the 0.5 s/r axial scan mode. CT dose index (CTDI) and quantitative image quality measurements were compared using the Student t test; qualitative image quality comparison was carried out using Mann-Whitney rank test and the inter-reviewer agreement was evaluated using Kappa test. RESULTS: The exposure time was 0.5 s for Group 1 and 3.27±0.29 s for Group 2. The CTDI in Group 1 was 9.74±0.86mGy, 36.38%lower than the 15.31mGy in Group 2 (p < 0.001). Group 1 and Group 2 had similar artifact index (2.06±1.06 vs. 2.37±1.18) in the cerebellar hemispheres, and similar contrast-to-noise ratio (2.32±0.83 vs. 1.69±0.68), (1.47±0.72 vs. 1.10±0.43) respectively for cerebellum and thalamus (p > 0.05). Image quality was acceptable for diagnosis, and motion artifacts were reduced in Group 1 (p < 0.001). CONCLUSION: Single rotation CT with 100 kVp and 70%ASIR-V on 16 cm wide-detector CT reduces radiation dose and motion artifacts for children with acute head trauma without compromising diagnostic quality as compared with standard dose protocol. Thus, it provides a novel imaging method in management of pediatric acute head trauma.


Assuntos
Traumatismos Craniocerebrais , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Criança , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
Acta Radiol ; 61(8): 1105-1115, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31795730

RESUMO

BACKGROUND: Patients with renal stones receive multiple computed tomography (CT) examinations. We investigated whether submillisievert (sub-mSv) CT for stone detection could reduce radiation dose at exposure levels comparable to kidney, ureter, and bladder (KUB) radiography. PURPOSE: To evaluate the radiation dose exposure, diagnostic performance, and image quality of sub-mSv non-contrast CT using advanced modelled iterative reconstruction algorithm with spectral filtration for the detection of urolithiasis. MATERIAL AND METHODS: A total of 145 consecutive patients underwent non-contrast CT using a third-generation dual-source scanner to obtain two datasets, i.e. 16.7% (sub-mSv CT, tube detector A) and 100% (standard-dose CT, combination of tube detector A and B) tube loads with spectral filtration. The performance of sub-mSv CT for the detection of stones was analyzed by two readers and compared with that of standard-dose CT. Image quality was measured subjectively and objectively. RESULTS: In total, 171 stones were detected in 79 patients. The mean effective radiation doses of sub-mSv CT was 0.3 mSv. The sensitivity and specificity values for diagnosis of stones measuring ≥3 mm was 95.1% and 100% for sub-mSv CT. The sensitivity and specificity for all stone detection was 74.9% and 97.8%, respectivey, for sub-mSv CT. The image quality was lower for sub-mSv CT than for standard-dose CT (P < 0.01). CONCLUSION: Sub-mSv CT can be achieved with radiation doses close to KUB radiography. Sub-mSv CT with spectral filtration can be used to detect stones measuring ≥3 mm and be used as a follow-up imaging modality as an alternative to KUB radiography.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Sensibilidade e Especificidade
11.
Pediatr Radiol ; 50(8): 1078-1082, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32415324

RESUMO

BACKGROUND: One main challenge in pediatric imaging is to reduce motion artifacts by calming young patients. To that end, the Radiological Society of North America (RSNA) as early as 1997 stated the necessity of adults accompanying their child during the child's examination. Nonetheless, current research lacks data regarding radiation dose to these chaperones. OBJECTIVE: The aim of this study was to measure the radiation dose of accompanying adults during state-of-the-art pediatric CT protocols. MATERIALS AND METHODS: In addition to a 100-kV non-contrast-enhanced chest CT (Protocol 1), we performed a 70-kV contrast-enhanced chest protocol (Protocol 2) using a third-generation dual-source CT. We acquired data on the radiation dose around the scanner using digital dosimetry placed right at the gantry, 1 m away, as well as beside the gantry. We acquired the CT-surrounding radiation dose during scanning of a pediatric phantom as well as 12 pediatric patients. RESULTS: After conducting 10 consecutive phantom scans using Protocol 1, we found the location with the highest cumulative dose acquired was right next to the gantry opening, at 3 µSv. Protocol 2 showed highest cumulative dose of 2 µSv at the same location. For Protocol 1, the location with the highest radiation doses during pediatric scans was right next to the gantry opening, with doses of 0.75±0.70 µSv. For Protocol 2, the highest radiation was measured 1 m away at 0.50±0.60 µSv. No radiation dose was measured at any time beside the gantry. CONCLUSION: Our results provide proof that chaperones receive low radiation doses during state-of-the-art CT examinations. Given knowledge of these values as well as the optimal spots with the lowest radiation doses, parents as well as patients might be more relaxed during the examination.


Assuntos
Acompanhantes Formais em Exames Físicos , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Criança , Meios de Contraste , Feminino , Humanos , Masculino , Imagens de Fantasmas , Monitoramento de Radiação
12.
Pediatr Radiol ; 50(9): 1240-1248, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32556576

RESUMO

BACKGROUND: Radiation dose at CT should be as low as possible without compromising diagnostic quality. OBJECTIVE: To assess the potential for maximum dose reduction of pediatric lung dual-source CT with spectral shaping and advanced iterative reconstruction (ADMIRE). MATERIALS AND METHODS: We retrospectively analyzed dual-source CT acquisitions in a full-dose group (FD: 100 kV, 64 reference mAs) and in three groups with spectral shaping and differing reference mAs values (Sn: 100 kV, 96/64/32 reference mAs), each group consisting of 16 patients (age mean 11.5 years, standard deviation 4.8 years, median 12.8 years, range 1.3-18 years). Advanced iterative reconstruction of images was performed with different strengths (FD: ADMIRE Level 2; Sn: ADMIRE Levels 2, 3 and 4). We analyzed dose parameters and measured noise. Diagnostic confidence and detectability of lung lesions as well as anatomical structures were assessed using a Likert scale (from 1 [unacceptable] to 4 [fully acceptable]). RESULTS: Compared to full dose, effective dose was reduced to 16.7% in the Sn 96 group, 11.1% in Sn64, and 5.5% in Sn32 (P<0.001). Noise values of Sn64ADM4 did not statistically differ from those in FDADM2 (45.7 vs. 38.9 Hounsfield units [HU]; P=0.132), whereas noise was significantly higher in Sn32ADM4 compared to Sn64ADM4 (61.5 HU; P<0.001). A Likert score >3 was reached in Sn64ADM4 regarding diagnostic confidence (3.2) and detectability of lung lesions (3.3). For detectability of most anatomical structures, no significant differences were found between FDAM2 and Sn64ADM4 (P≥0.05). CONCLUSION: In pediatric lung dual-source CT, spectral shaping together with ADMIRE 4 enable radiation dose reduction to about 10% of a full-dose protocol while maintaining an acceptable diagnostic quality.


Assuntos
Pneumopatias/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
13.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 76(10): 1035-1043, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33087649

RESUMO

This study evaluated the effects of three types of hybrid iterative reconstruction (IR) on image quality of pediatric body computed tomography images. The image quality components evaluated were noise power spectrum (NPS), task-based modulation transfer function (TTF), and system performance function (SPF). As the IR strength was increased while reducing the radiation dose, the NPS increased in a low-frequency range and the TTF decreased in low-contrast regions. In the low-contrast regions, the calculated SPF decreased over the entire frequency range. Alternatively, in the high-contrast regions, the SPF decreased in the low-frequency regions and increased in the high-frequency regions. The radiation dose reduction using the hybrid IR resulted in the deterioration of the image quality in the low-contrast regions and changes in the spatial frequency characteristics in the high-contrast regions.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Criança , Coleta de Dados , Humanos , Imagens de Fantasmas , Doses de Radiação
14.
Eur J Nucl Med Mol Imaging ; 46(6): 1248-1256, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30411141

RESUMO

PURPOSE: Guidelines propose different rest-stress activity ratios (RSAR) for one-day stress-first SPECT myocardial perfusion imaging (MPI), but evidence is limited. Our aim was to determine and validate the minimal RSAR resulting in the same diagnostic outcome in one-day stress-first SPECT MPI. METHODS: Forty-seven patients referred for rest after stress CZT-SPECT/CT MPI were prospectively included. Rest acquisitions were performed 3 h after stress. In addition to the stress and rest acquisitions, the first 22 patients underwent an additional acquisition prior to the rest injection to determine the remaining stress activity. Next, we simulated six RSARs varying from 1.0 to 3.5 in both patients and a phantom and compared the images to those using the reference RSAR of 4.0. Differences in summed difference score (SDS) >2 or ischemic defect interpretation were considered to significantly influence diagnostic outcome. After deriving the minimal RSAR, it was validated in 25 additional patients by comparing it to a RSAR of 4.0. RESULTS: After 3 h only 26% of the stress activity was still present in the myocardium. SDS differences >2 were found in one (4%) patient using RSAR of 3.5, 2.5 and 2.0, in three (12%) using 1.5 and in five (20%) using SRAR of 1.0. These results were consistent with the phantom study showing SDS differences >2 for RSARs ≤1.5 and with the visual interpretation which showed an increased number of deviating scans for RSAR 1.0. Validating the RSAR of 2.0 resulted in a different SDS in one patient (SDS of 30 versus 11). Moreover, two scans were interpreted as ischemic instead of normal when using RSAR 2.0 and in two other scans the opposite was the case. CONCLUSIONS: A RSAR of 2.0 in one-day stress-first MPI SPECT seems sufficient to obtain accurate diagnostic outcomes and is therefore recommended to reduce radiation exposure.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Algoritmos , Cádmio/química , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Imagens de Fantasmas , Estudos Prospectivos , Cintilografia , Descanso , Telúrio/química , Zinco/química
15.
AJR Am J Roentgenol ; 212(1): 151-156, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30422712

RESUMO

OBJECTIVE: The purpose of this study was to quantify the dose reduction resulting from the use of lead aprons for pediatric chest CT as a function of the distance between the apron and the bottom of the scan range. MATERIALS AND METHODS: Semianthropomorphic phantoms of the head, abdomen, and pelvis were placed adjacent to a chest phantom to mimic the habitus of a 5-year-old child. A chest CT scan was performed, and a point dosimeter was used to measure the radiation dose at points within and outside the scan range. A lead apron was placed 1, 5, and 10 cm from the bottom of the CT scan range, and the measurements were repeated. The weighted-average dose was calculated for each measurement position. RESULTS: The weighted-average dose within and outside the scan range was 1.7 and 0.067 mGy, respectively. The mean (percentage) dose reduction outside the scan range resulting from use of the lead apron was 0.013 mGy (19.1%), 0.007 mGy (10.1%), and 0.003 mGy (4.3%) when the lead apron was placed at distances of 1, 5, and 10 cm from the bottom of the scan range, respectively. The corresponding total percentage dose reduction (including the dose from the primary scan) was 0.7%, 0.4%, and 0.2%, respectively. CONCLUSION: As the lead apron was placed farther from the scan range, the amount of dose reduction diminished. The reduction in dose was extremely small compared with the overall dose from the examination. The small dose reduction gained from the use of lead shielding over the abdomen and pelvis during chest CT examination of pediatric patients may not outweigh the associated potential risks of artifacts and infection.


Assuntos
Equipamentos de Proteção , Proteção Radiológica/instrumentação , Radiografia Torácica , Tomografia Computadorizada por Raios X , Pré-Escolar , Feminino , Humanos , Chumbo , Masculino , Órgãos em Risco , Imagens de Fantasmas , Doses de Radiação , Fatores de Risco
16.
Skeletal Radiol ; 48(3): 375-385, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30155628

RESUMO

OBJECTIVE: To analyze the impact of pelvic computed tomography (CT) technique optimization on estimated dose and subjective and objective image quality. MATERIALS AND METHODS: An institutional review board (IRB)-approved retrospective records review was performed with waived informed consent. Five CT scanners (various manufacturers/models) were standardized to match the lowest dose profile on campus via subjective assessment of clinical images by experienced musculoskeletal radiologists. The lowest dose profile had previously been established through image assessment by experienced musculoskeletal radiologists after a department-wide radiation dose reduction initiative. A consecutive series of 60 pre- and 59 post-optimization bony pelvis CTs were analyzed by two residents, who obtained signal-to-noise ratio for femoral cortex and marrow, gluteus medius muscle, and subcutaneous and visceral fat in a standardized fashion. Two blinded attending radiologists ranked image quality from poor to excellent. RESULTS: Pre- and post-optimization subjects exhibited no difference in gender, age, or BMI (p > 0.2). Mean CT dose index (CTDIvol) and dose-length product (DLP) decreased by approximately 45%, from 39± 14 to 18± 12 mGy (p < 0.0001) and 1,227± 469 to 546± 384 mGy-cm (p < 0.0001). Lower body mass index (BMI) was associated with a larger dose reduction and higher BMI with higher DLP regardless of pre- or post-optimization examination. Inter-observer agreement was 0.64-0.92 for SNR measurements. Cortex SNR increased significantly for both observers (p < 0.02). Although qualitative image quality significantly decreased for one observer (p < 0.01), adequate mean quality (3.3 out of 5) was maintained for both observers. CONCLUSION: Subjective and objective image quality for pelvic CT examination remains adequate, despite a substantially reduced radiation dose.


Assuntos
Pelve/diagnóstico por imagem , Proteção Radiológica/métodos , Tomógrafos Computadorizados/normas , Tomografia Computadorizada por Raios X/normas , Feminino , Humanos , Masculino , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído
17.
Skeletal Radiol ; 48(11): 1775-1785, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31016340

RESUMO

OBJECTIVE: To evaluate the impact of radiation dose reduction on image quality in patients with metal-on-metal total hip arthroplasties (THAs) using model-based iterative reconstruction (MBIR) combined with orthopaedic metal artefact reduction (O-MAR). MATERIALS AND METHODS: Patients with metal-on-metal THAs received a pelvic CT with a full (FD) and a reduced radiation dose (RD) with -20%, -40%, -57%, or -80% CT radiation dose respectively, when assigned to group 1, 2, 3, or 4 respectively. FD acquisitions were reconstructed with iterative reconstruction, iDose4. RD acquisitions were additionally reconstructed with iterative model-based reconstruction (IMR) levels 1-3 with different levels of noise suppression. CT numbers, noise and contrast-to-noise ratios were measured in muscle, fat and bladder. Subjective image quality was evaluated on seven aspects including artefacts, osseous structures, prosthetic components and soft tissues. RESULTS: Seventy-six patients were randomly assigned to one of the four groups. While reducing radiation dose by 20%, 40%, 57%, or 80% in combination with IMR, CT numbers remained constant. Compared with iDose4, the noise decreased (p < 0.001) and contrast-to-noise ratios increased (p < 0.001) with IMR. O-MAR improved CT number accuracy in the bladder and reduced noise in the bladder, muscle and fat (p < 0.01). Subjective image quality was rated lower on RD IMR images than FD iDose4 images on all seven aspects (p < 0.05) and was not related to the applied radiation dose reduction. CONCLUSION: In RD IMR with O-MAR images, CT numbers remained constant, noise decreased and contrast-to-noise ratios between muscle and fat increased compared with FD iDose4 with O-MAR images in patients with metal-on-metal THAs. Subjective image quality reduced, regardless of the degree of radiation dose reduction.


Assuntos
Artroplastia de Quadril , Artefatos , Articulação do Quadril/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Ortopedia , Reprodutibilidade dos Testes
18.
Emerg Radiol ; 26(2): 169-177, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30448900

RESUMO

OBJECTIVES: Performance of a modified abdominopelvic CT protocol reconstructed using full iterative reconstruction (IR) was assessed for imaging patients presenting with acute abdominal symptoms. MATERIALS AND METHODS: Fifty-seven patients (17 male, 40 female; mean age of 56.5 ± 8 years) were prospectively studied. Low-dose (LD) and conventional-dose (CD) CTs were contemporaneously acquired between November 2015 and March 2016. The LD and CD protocols imparted radiation exposures approximating 10-20% and 80-90% those of routine abdominopelvic CT, respectively. The LD images were reconstructed with model-based iterative reconstruction (MBIR), and CD images with hybrid IR (40% adaptive statistical iterative reconstruction (ASIR)). Image quality was assessed quantitatively and qualitatively. Independent clinical interpretations were performed with a 6-week delay between reviews. RESULTS: A 74.7% mean radiation dose reduction was achieved: LD effective dose (ED) 2.38 ± 1.78 mSv (size-specific dose estimate (SSDE) 3.77 ± 1.97 mGy); CD ED 7.04 ± 4.89 mSv (SSDE 10.74 ± 5.5 mGy). LD-MBIR images had significantly lower objective and subjective image noise compared with CD-ASIR (p < 0.0001). Noise reduction for LD-MBIR studies was greater for patients with BMI < 25 kg/m2 than those with BMI ≥ 25 kg/m2 (5.36 ± 3.2 Hounsfield units (HU) vs. 4.05 ± 3.1 HU, p < 0.0001). CD-ASIR studies had significantly better contrast resolution, and diagnostic acceptability (p < 0.0001 for all). LD-MBIR studies had significantly lower streak artifact (p < 0.0001). There was no difference in sensitivity for primary findings between the low-dose and conventional protocols with the exception of one case of enteritis. CONCLUSIONS: Low-dose abdominopelvic CT performed with MBIR is a feasible radiation dose reduction strategy for imaging patients presenting with acute abdominal pain.


Assuntos
Abdome Agudo/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Diatrizoato de Meglumina , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade
19.
J Nucl Cardiol ; 25(1): 26-35, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28822102

RESUMO

BACKGROUND: SPECT Myocardial perfusion imaging (MPI) is associated with a relatively high radiation burden and decreasing image quality in heavy patients. Patient-specific low-activity protocols (PLAPs) are suggested but follow-up data is lacking. Our aim was to compare the use of a standard fixed-activity protocol (FAP) with a PLAP in cadmium zinc telluride (CZT)-SPECT MPI. METHODS: We retrospectively included 1255 consecutive patients who underwent CZT-SPECT stress-optional rest MPI. 668 Patients were scanned using FAP (370 MBq) and 587 patients using PLAP (2.25 MBq·kg-1). Percentage of scans interpreted as normal, radiation dose, and 1-year follow-up including hard event rates (all-cause death or non-fatal myocardial infarction) were collected and compared. RESULTS: The percentage of scans interpreted as normal was 67% in FAP and 70% in PLAP groups (P = .29). The annualized hard event rates in these patients were 1.0% in the FAP and 0.9% in the PLAP group (P = .86). However, the mean radiation dose decreased by 23% for stress-only and by 15% to 2.6 mSv for stress-optional rest MPI after introduction of the PLAP (p<0.001). CONCLUSIONS: Introduction of a patient-specific low-activity protocol does not affect the percentage of scans interpreted as normal or prognosis but significantly lowers the radiation dose for CZT-SPECT MPI.


Assuntos
Cádmio , Imagem de Perfusão do Miocárdio , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Peso Corporal , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Seguimentos , Câmaras gama , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Doses de Radiação , Cintilografia , Compostos Radiofarmacêuticos/farmacologia , Estudos Retrospectivos
20.
AJR Am J Roentgenol ; 210(1): 127-133, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29140117

RESUMO

OBJECTIVE: The purpose of this study is to compare radiation dose and image quality of abdominopelvic CT studies reconstructed with iterative and conventional techniques. MATERIALS AND METHODS: This retrospective study enrolled 99 patients who underwent abdominopelvic CT examinations with the portal venous phase images reconstructed with both filtered back projection and Adaptive Iterative Dose Reduction 3D (AIDR 3D) at different time points. Subjective assessment of image quality was performed by two radiologists who scored axial images for overall quality, sharpness, noise, and acceptability in a blinded fashion. The SD of the mean attenuation of the liver, aorta, and paraspinal muscle (as a measurement of image noise) and contrast-to-noise and signal-to-noise ratios for liver and aorta were used as objective parameters of image quality. Radiation dose parameters included CT dose index volume (CTDIvol), dose-length product, effective dose (ED), and size-specific dose estimate (SSDE). Results were compared for different body mass index (BMI; weight in kilograms divided by the square of height in meters) categories. Paired t test and McNemar paired tests for noninferiority were used, with p < 0.05 considered statistically significant. RESULTS: We obtained a 62.5% mean reduction in CTDIvol, a 58% mean reduction in ED, and a 63% mean reduction in SSDE when AIDR 3D was used (p < 0.001). Subjective parameters of image quality were considered noninferior for AIDR 3D studies compared with filtered back projection (p < 0.001), except for the sharpness of images of patients with BMI 20-24.9. Variable results were found regarding objective assessment of image quality. CONCLUSION: AIDR 3D allowed a significant reduction in radiation dose of abdominopelvic CT examinations without a loss of image quality in general.


Assuntos
Abdome/diagnóstico por imagem , Imageamento Tridimensional , Pelve/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA