Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.370
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 79(6): 1306-1314.e2, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38368998

RESUMO

OBJECTIVE: Radiation exposure during complex endovascular aortic repair may be associated with tangible adverse effects in patients and operators. This study aimed to identify the steps of highest radiation exposure during fenestrated endovascular aortic repair (FEVAR) and to investigate potential intraoperative factors affecting radiation exposure. METHODS: Prospective data of 31 consecutive patients managed exclusively with four-fenestration endografts between March 1, 2020, and July 1, 2022 were retrospectively analyzed. Leveraging the conformity of the applied technique, every FEVAR operation was considered a combination of six overall stages composed of 28 standardized steps. Intraoperative parameters, including air kerma, dose area product, fluoroscopy time, and number of digital subtraction angiographies (DSAs) and average angulations were collected and analyzed for each step. RESULTS: The mean procedure duration and fluoroscopy time was 140 minutes (standard deviation [SD], 32 minutes), and 40 minutes (SD, 9.1 minutes), respectively. The mean air kerma was 814 mGy (SD, 498 mGy), and the mean dose area product was 66.8 Gy cm2 (SD, 33 Gy cm2). The percentage of air kerma of the entire procedure was distributed throughout the following procedure stages: preparation (13.9%), main body (9.6%), target vessel cannulation (27.8%), stent deployment (29.1%), distal aortoiliac grafting (14.3%), and completion (5.3%). DSAs represented 23.0% of the total air kerma. Target vessel cannulation and stent deployment presented the highest mean lateral angulation (67 and 63 degrees, respectively). Using linear regression, each minute of continuous fluoroscopy added 18.9 mGy of air kerma (95% confidence interval, 17.6-20.2 mGy), and each DSA series added 21.1 mGy of air kerma (95% confidence interval, 17.9-24.3 mGy). Body mass index and lateral angulation were significantly associated with increased air kerma (P < .001). CONCLUSIONS: Cannulation of target vessels and bridging stent deployment are the steps requiring the highest radiation exposure during FEVAR cases. Optimized operator protection during these steps is mandatory.


Assuntos
Implante de Prótese Vascular , Correção Endovascular de Aneurisma , Doses de Radiação , Exposição à Radiação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Digital , Aortografia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma/efeitos adversos , Fluoroscopia , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/efeitos adversos , Duração da Cirurgia , Exposição à Radiação/prevenção & controle , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
2.
J Vasc Surg ; 79(4): 948-953, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38040201

RESUMO

OBJECTIVE: Breast cancer most commonly occurs in the upper outer quadrant (UOQ) chest wall (CW). The effectiveness of routine leaded aprons to protect this region of the body in interventionalists during fluoroscopically guided interventions (FGIs) is unknown. Given the high lifetime attributable risks of prolonged occupational exposure to ionizing radiation and the increasing number of practicing female vascular surgeons and interventionalists, we sought to determine if the use of a leaded arm shield would offer additional protection to the lateral CW and axilla in operators compared with routine leaded aprons. METHODS: Effectiveness of leaded sleeves in attenuating radiation dose to the axilla and UOQ was evaluated in clinical practice and simulated scenarios. In the clinical setting, optically stimulated luminescence nanoDot detectors were placed at the UOQ lateral CW position, both over and under a standard leaded apron vest with and without the addition of an antimony/bismuth Enviro-Lite sleeve on two vascular surgeons performing FGIs. In the simulation, nanoDots were similarly placed on an anthropomorphic phantom positioned to represent a primary operator performing right femoral access. Fluorography was performed on 12-inch-thick acrylic scatter phantom at 80 kVp for an exposure of 3 Gy reference air kerma. Experiments were done with and without the sleeve. Paired Wilcoxon and χ2 tests were performed to identify the statistical significance of radiation attenuation. RESULTS: Operator UOQ CW dose was measured during 61 FGIs: 33 cases (54%) with and 28 cases (46%) without the sleeve. Median procedure reference air kerma and fluoroscopy time was 180 mGy (interquartile range [IQR], 85-447 mGy) and 21 minutes (IQR, 11-39 minutes) when the sleeve was worn vs 100 mGy (IQR, 67-270 mGy) and 11 minutes (IQR, 6.3-25 minutes) without the sleeve. Radiation dose to the operator's UOQ was reduced by 96% (IQR, 85%-96%) when the sleeve was present and by 62% (IQR, 44%-82%; P < .001) without the sleeve. In the simulated setting, the sleeve reduced the radiation dose to the UOQ compared with the apron alone (96% vs 67%; P < .001). CONCLUSIONS: Routine leaded aprons do attenuate the majority of UOQ chest wall radiation dose; however, the addition of a lead-equivalent sleeve further significantly reduces this dose. Because this area of the body has a high incidence of cancer formation, additional protection, especially to female interventionalists, seems prudent. Vascular surgeons should consider using a protective sleeve with their personal protective equipment when performing complex fluoroscopically guided procedures.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Parede Torácica , Humanos , Feminino , Doses de Radiação , Braço , Roupa de Proteção , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Fluoroscopia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos
3.
Eur J Nucl Med Mol Imaging ; 51(10): 2903-2921, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38189911

RESUMO

Radioguidance that makes use of ß-emitting radionuclides is gaining in popularity and could have potential to strengthen the range of existing radioguidance techniques. While there is a strong tendency to develop new PET radiotracers, due to favorable imaging characteristics and the success of theranostics research, there are practical challenges that need to be overcome when considering use of ß-emitters for surgical radioguidance. In this position paper, the EANM identifies the possibilities and challenges that relate to the successful implementation of ß-emitters in surgical guidance, covering aspects related to instrumentation, radiation protection, and modes of implementation.


Assuntos
Partículas beta , Partículas beta/uso terapêutico , Humanos , Radioisótopos/química , Medicina Nuclear , Compostos Radiofarmacêuticos , Cirurgia Assistida por Computador/métodos , Proteção Radiológica/métodos
4.
Eur Radiol ; 34(1): 411-421, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552254

RESUMO

OBJECTIVES: Cardiac computed tomography (CT) is essential in diagnosing coronary heart disease. However, a disadvantage is the associated radiation exposure to the patient which depends in part on the scan range. This study aimed to develop a deep neural network to optimize the delimitation of scan ranges in CT localizers to reduce the radiation dose. METHODS: On a retrospective training cohort of 1507 CT localizers randomly selected from calcium scoring and angiography scans and acquired between 2010 and 2017, optimized scan ranges were delimited by two radiologists in consensus. A neural network was trained to reproduce the scan ranges and was tested on two randomly selected and independent validation cohorts: an internal cohort of 233 CT localizers (January 2018-June 2020) and an external cohort from a nearby hospital of 298 CT localizers (July 2020-December 2020). Localizers where a bypass surgery was visible were excluded. The effective radiation dose to the patient was simulated using a Monte Carlo simulation. Scan ranges of radiographers, radiologists, and the network were compared using an equivalence test; likewise, the reduction in effective dose was tested using a superior test. RESULTS: The network replicated the radiologists' scan ranges with a Dice score of 96.5 ± 0.02 (p < 0.001, indicating equivalence). The generated scan ranges resulted in an effective dose reduction of 10.0% (p = 0.002) in the internal cohort and 12.6% (p < 0.001) in the external cohort compared to the scan ranges delimited by radiographers in clinical routine. CONCLUSIONS: Automatic delimitation of the scan range can result in a radiation dose reduction to the patient. CLINICAL RELEVANCE STATEMENT: Fully automated delimitation of the scan range using a deep neural network enables a significant reduction in radiation exposure during CT coronary angiography compared to manual examination planning. It can also reduce the workload of the radiographers. KEY POINTS: • Scan range delimitation for coronary computed tomography angiography could be performed with high accuracy by a deep neural network. • Automated scan ranges showed a high agreement of 96.5% with the scan ranges of radiologists. • Using a Monte Carlo simulation, automated scan ranges reduced the effective dose to the patient by up to 12.6% (0.9 mSv) compared to the scan ranges of radiographers in clinical routine.


Assuntos
Aprendizado Profundo , Exposição à Radiação , Humanos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Estudos Retrospectivos , Exposição à Radiação/prevenção & controle
5.
Eur Radiol ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39012526

RESUMO

OBJECTIVES: The randomized TOmosynthesis plus SYnthesized MAmmography (TOSYMA) screening trial has shown that digital breast tomosynthesis plus synthesized mammography (DBT + SM) is superior to digital mammography (DM) in invasive breast cancer detection varying with breast density. On the other hand, the overall average glandular dose (AGD) of DBT is higher than that of DM. Comparing the DBT + SM and DM trial arm, we analyzed here the mean AGD and their determinants per breast density category and related them to the respective invasive cancer detection rates (iCDR). METHODS: TOSYMA screened 99,689 women aged 50 to 69 years. Compression force, resulting breast thickness, the calculated AGD obtained from each mammography device, and previously published iCDR were used for comparisons across breast density categories in the two trial arms. RESULTS: There were 196,622 exposures of 49,227 women (DBT + SM) and 197,037 exposures of 49,132 women (DM) available for analyses. Mean breast thicknesses declined from breast density category A (fatty) to D (extremely dense) in both trial arms. However, while the mean AGD in the DBT + SM arm declined concomitantly from category A (2.41 mGy) to D (1.89 mGy), it remained almost unchanged in the DM arm (1.46 and 1.51 mGy, respectively). In relative terms, the AGD elevation in the DBT + SM arm (64.4% (A), by 44.5% (B), 27.8% (C), and 26.0% (D)) was lowest in dense breasts where, however, the highest iCDR were observed. CONCLUSION: Women with dense breasts may specifically benefit from DBT + SM screening as high cancer detection is achieved with only moderate AGD elevations. CLINICAL RELEVANCE STATEMENT: TOSYMA suggests a favorable constellation for screening with digital breast tomosynthesis plus synthesized mammography (DBT + SM) in dense breasts when weighing average glandular dose elevation against raised invasive breast cancer detection rates. There is potential for density-, i.e., risk-adapted population-wide breast cancer screening with DBT + SM. KEY POINTS: Breast thickness declines with visually increasing density in digital mammography (DM) and digital breast tomosynthesis (DBT). Average glandular doses of DBT decrease with increasing density; digital mammography shows lower and more constant values. With the smallest average glandular dose difference in dense breasts, DBT plus SM had the highest difference in invasive breast cancer detection rates.

6.
BMC Gastroenterol ; 24(1): 173, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762503

RESUMO

BACKGROUND: There have been previous studies and earlier systematic review on the relationship between inflammatory bowel disease (IBD) and radiation exposure. With the diversification of current test methods, this study intended to conduct a meta-analysis to evaluate the IBD radiation exposure in recent years. METHODS: Three databases (PUBMED, EMBASE, and MEDICINE) for relevant literature up to May 1, 2023 were searched. The statistical data meeting requirements were collated and extracted. RESULTS: 20 papers were enrolled. The overall high radiation exposure rate was 15% (95% CI = [12%, 19%]) for CD and 5% (95% CI = [3%, 7%]) for UC. The pooled result found that high radiation exposure rate was 3.44 times higher in CD than in UC (OR = 3.44, 95% CI = [2.35, 5.02]). Moreover, the average radiation exposure level in CD was 12.77 mSv higher than that in UC (WMD = 12.77, 95% CI = [9.93, 15.62] mSv). Furthermore, radiation exposure level of CD after 2012 was higher than those before 2012 (26.42 ± 39.61vs. 23.76 ± 38.46 mSv, P = 0.016), while UC did not show similar result (11.99 ± 27.66 vs. 10.01 ± 30.76 mSv, P = 0.1). Through subgroup analysis, it was found that disease duration (WMD = 2.75, 95% CI = [0.10, 5.40] mSv), complications (OR = 5.09, 95% CI = [1.50, 17.29]), and surgical history (OR = 5.46, 95% CI = [1.51, 19.69]) significantly increased the proportion of high radiation exposure. CONCLUSION: This study found that radiation exposure level of IBD patients was high, which revealed the radiation risk in the process of diagnosis and treatment of IBD patients. In the future, longer follow-up and prospective studies are needed to reveal the relationship between high radiation exposure and solid tumorigenesis.


Assuntos
Exposição à Radiação , Humanos , Exposição à Radiação/efeitos adversos , Colite Ulcerativa , Doenças Inflamatórias Intestinais , Doença de Crohn , Doses de Radiação
7.
Environ Res ; 251(Pt 1): 118634, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38452915

RESUMO

Several human studies indicate that mobile phone specific electromagnetic fields may cause cancer in humans but the underlying molecular mechanisms are currently not known. Studies concerning chromosomal damage (which is causally related to cancer induction) are controversial and those addressing this issue in mobile phone users are based on the use of questionnaires to assess the exposure. We realized the first human intervention trial in which chromosomal damage and acute toxic effects were studied under controlled conditions. The participants were exposed via headsets at one randomly assigned side of the head to low and high doses of a UMTS signal (n = 20, to 0.1 W/kg and n = 21 to 1.6 W/kg Specific Absorption Rate) for 2 h on 5 consecutive days. Before and three weeks after the exposure, buccal cells were collected from both cheeks and micronuclei (MN, which are formed as a consequence of structural and numerical chromosomal aberrations) and other nuclear anomalies reflecting mitotic disturbance and acute cytotoxic effects were scored. We found no evidence for induction of MN and of nuclear buds which are caused by gene amplifications, but a significant increase of binucleated cells which are formed as a consequence of disturbed cell divisions, and of karyolitic cells, which are indicative for cell death. No such effects were seen in cells from the less exposed side. Our findings indicate that mobile phone specific high frequency electromagnetic fields do not cause acute chromosomal damage in oral mucosa cells under the present experimental conditions. However, we found clear evidence for disturbance of the cell cycle and cytotoxicity. These effects may play a causal role in the induction of adverse long term health effects in humans.


Assuntos
Telefone Celular , Citocinese , Mucosa Bucal , Humanos , Mucosa Bucal/efeitos da radiação , Mucosa Bucal/citologia , Adulto , Masculino , Citocinese/efeitos da radiação , Morte Celular/efeitos da radiação , Adulto Jovem , Feminino , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos , Campos Eletromagnéticos/efeitos adversos , Micronúcleos com Defeito Cromossômico/efeitos da radiação
8.
Eur J Pediatr ; 183(4): 1911-1916, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38334796

RESUMO

The purpose of this study is to evaluate radiation exposure in newborns undergoing imaging tests during the first 30 days of neonatal intensive care unit (NICU) hospitalization. A retrospective cohort study was conducted from November 2018 to April 2019 with newborns admitted to the NICU. Thermoluminescent dosimeters (TLD-100™) measured radiation emitted during imaging exams over 1 month, with a comparison between measured and estimated radiation. The cohort exhibited a median gestational age of 33.0 (31.0, 37.0) weeks, a median birth weight of 1840 (1272, 2748) g, and a median length of stay of 25.5 (11.7, 55.0) days. Eighty-four patients underwent 314 imaging tests, with an estimated radiation dose (ERD) per patient of 0.116 mSv and a measured radiation dose (MDR) of 0.158 mSv. ERD consistently underestimated MDR, with a mean difference of -0.043 mSv (-0.049 to -0.036) in the Bland-Altman analysis. The regression equation was as follows: difference MRD - ERD = -1.7 × (mean (MRD + ERD)) + 0.056. The mean estimated radiation dose per exam was 0.030 mSv, and the chest X-rays accounted for 63.26% of total exams. The median number of radiographic incidences per patient was 2 (1, 4), with 5 patients undergoing three or more exams in a single day. CONCLUSION: Radiation exposure in these newborns was underestimated, emphasizing the need for awareness regarding associated risks and strict criteria for requesting radiological exams. Lung ultrasound is a radiation-free and effective option in managing respiratory diseases in newborns, reducing the reliance on chest X-rays. WHAT IS KNOWN: • Radiation used in diagnostic exams is not risk-free. • Radiation risk is much higher in small Infants due to the exposure area and the prolonged expectance of life. WHAT IS NEW: • Radiation exposure is underestimated in the neonatal population. • The study found a mean radiation exposure in neonates about 5% of the mean annual dose in the general population.


Assuntos
Unidades de Terapia Intensiva Neonatal , Exposição à Radiação , Lactente , Humanos , Recém-Nascido , Estudos Retrospectivos , Doses de Radiação , Radiografia , Exposição à Radiação/efeitos adversos
9.
Respirology ; 29(9): 803-814, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38806394

RESUMO

BACKGROUND AND OBJECTIVE: Robotic-assisted bronchoscopy (RAB) is an emerging modality to sample pulmonary lesions. Cone-beam computed tomography (CBCT) can be incorporated into RAB. We investigated the magnitude and predictors of patient and staff radiation exposure during mobile CBCT-guided shape-sensing RAB. METHODS: Patient radiation dose was estimated by cumulative dose area product (cDAP) and cumulative reference air kerma (cRAK). Staff equivalent dose was calculated based on isokerma maps and a phantom simulation. Patient, lesion and procedure-related factors associated with higher radiation doses were identified by logistic regression models. RESULTS: A total of 198 RAB cases were included in the analysis. The median patient cDAP and cRAK were 10.86 Gy cm2 (IQR: 4.62-20.84) and 76.20 mGy (IQR: 38.96-148.38), respectively. Among staff members, the bronchoscopist was exposed to the highest median equivalent dose of 1.48 µSv (IQR: 0.85-2.69). Both patient and staff radiation doses increased with the number of CBCT spins and targeted lesions (p < 0.001 for all comparisons). Patient obesity, negative bronchus sign, lesion size <2.0 cm and inadequate sampling by on-site evaluation were associated with a higher patient dose, while patient obesity and inadequate sampling by on-site evaluation were associated with a higher bronchoscopist equivalent dose. CONCLUSION: The magnitude of patient and staff radiation exposure during CBCT-RAB is aligned with safety thresholds recommended by regulatory authorities. Factors associated with a higher radiation exposure during CBCT-RAB can be identified pre-operatively and solicit procedural optimization by reinforcing radiation protective measures. Future studies are needed to confirm these findings across multiple institutions and practices.


Assuntos
Broncoscopia , Tomografia Computadorizada de Feixe Cônico , Exposição à Radiação , Procedimentos Cirúrgicos Robóticos , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Broncoscopia/métodos , Broncoscopia/efeitos adversos , Masculino , Feminino , Exposição à Radiação/efeitos adversos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Exposição Ocupacional/efeitos adversos , Idoso , Doses de Radiação , Imagens de Fantasmas , Adulto , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
10.
Endocr Pract ; 30(4): 319-326, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38184241

RESUMO

OBJECTIVE: Molecular testing is a well-established tool that assists in the management of thyroid nodules. We describe our experience using molecular testing of thyroid nodules with Bethesda III to VI cytology. METHODS: This is a retrospective multicenter, multinational study of thyroid nodules that underwent preoperative molecular profiling with ThyGenX/ThyGeNEXT or ThyroSeq V3 between 2015 and 2022. The clinical characteristics and mutational profiles of tumors were compared. Collected data included demographics, cytology results, surgical pathology, and molecular alterations. Molecular alterations were categorized into 3 main phenotypes: BRAF-like, RAS-like, and non-BRAF-non-RAS (NBNR). RESULTS: Overall, 784 patients who had surgery were included, of which 603 (76.2%) were females. The most common histologic type was papillary thyroid cancer (PTC) with 727 (91.9%) cases. In total, 205 (28.2%) cases showed an aggressive subtype of PTC (eg, tall cell and hobnail). BRAF-like alterations were most likely to be found in Bethesda V and VI nodules and show extrathyroidal extension (ETE), nodal disease, and/or aggressive subtypes of PTC (P < .001 for all). RAS-like alterations were more commonly found in Bethesda III and IV nodules and were less likely to show ETE, nodal disease, and/or aggressive histology (P < .001 for all). NBNR alterations were more commonly found in Bethesda III and IV nodules and were less likely to show ETE, nodal disease, and/or aggressive subtypes of PTC. However, they were rarely but significantly associated with poorly differentiated thyroid cancer (P < .005). CONCLUSION: Molecular testing of thyroid nodules can help determine the likelihood of malignancy and classify nodules into several tumor phenotypes, predicting their behaviors and potentially allowing for a more tailored treatment. NBNR alterations should be managed with caution.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Feminino , Humanos , Masculino , Nódulo da Glândula Tireoide/patologia , Estudos Retrospectivos , Proteínas Proto-Oncogênicas B-raf/genética , Biópsia por Agulha Fina , Neoplasias da Glândula Tireoide/patologia , Câncer Papilífero da Tireoide/genética , Mutação
11.
Paediatr Anaesth ; 34(6): 551-558, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38389210

RESUMO

BACKGROUND: In children, central venous catheter (CVC) placement is usually performed under ultrasound guidance for optimal visualization of vessels and reduction of puncture-related complications. Nevertheless, in many cases, additional radiographic examinations are performed to check the position of the catheter tip. AIM: The primary objective of this observational feasibility study was to determine the number of ultrasound-guided central venous catheter tips that can be identified in a subsequent position check using ultrasonography. Furthermore, we investigated the optimal ultrasound window, time expenditure, and success rate concerning puncture attempts and side effects. In addition, we compared the calculated and real insertion depths and analyzed the position of the catheter tip on postoperative radiographs with the tracheal bifurcation as a traditional landmark. METHODS: Ninety children with congenital heart defects who required a central venous line for cardiac surgery were included in this single-center study. After the insertion of the catheter, the optimal position of its tip was controlled using one of four predefined ultrasound windows. A chest radiograph was obtained postoperatively in accordance with hospital standards to check the catheter tip position determined by ultrasonography. RESULTS: The children had a median (IQR) age of 11.5 (4.0, 58.8) months and a mean (SD) BMI of 15.3 (2.91) kg/m2 Ultrasound visualization of the catheter tip was successful in 86/90 (95.6%) children (95% confidence interval [CI]: 91.3%, 99.8%). Postoperative radiographic examination showed that the catheter tip was in the desired position in 94.4% (95% CI: 89.7%, 99.2%) of the cases. None of the children needed the catheter tip position being corrected based on chest radiography. CONCLUSION: Additional radiation exposure after the placement of central venous catheters can be avoided with the correct interpretation of standardized ultrasound windows, especially in vulnerable children with cardiac disease.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Estudos de Viabilidade , Cardiopatias Congênitas , Ultrassonografia de Intervenção , Humanos , Estudos Prospectivos , Masculino , Feminino , Pré-Escolar , Cateterismo Venoso Central/métodos , Ultrassonografia de Intervenção/métodos , Lactente , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos , Criança
12.
Pediatr Radiol ; 54(4): 646-652, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38472490

RESUMO

Hand-wrist radiography is the most common and accurate method for evaluating children's bone age. To reduce the scattered radiation of radiosensitive organs in bone age assessment, we designed a small X-ray instrument with radioprotection function by adding metal enclosure for X-ray shielding. We used a phantom operator to compare the scattered radiation doses received by sensitive organs under three different protection scenarios (proposed instrument, radiation personal protective equipment, no protection). The proposed instrument showed greater reduction in the mean dose of a single exposure compared with radiation personal protective equipment especially on the left side which was proximal to the X-ray machine (≥80.0% in eye and thyroid, ≥99.9% in breast and gonad). The proposed instrument provides a new pathway towards more convenient and efficient radioprotection.


Assuntos
Proteção Radiológica , Criança , Humanos , Doses de Radiação , Raios X , Radiografia , Proteção Radiológica/métodos , Fluoroscopia , Imagens de Fantasmas
13.
Int J Biometeorol ; 68(1): 17-31, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37924391

RESUMO

Since pedestrians are impacted by solar radiation differently, urban designers must evaluate solar radiation exposure of pedestrian paths adopting an inclusive approach. This paper proposes a maximum threshold of direct solar radiation exposure for pedestrians based on activity, user profile and environmental conditions, defined as the difference between the energy consumption before feeling exhausted and the energy cost of walking. Two users of diverse walking abilities, a young adult and an elderly person with mobility impairment, were characterised by metabolic activity, walking speed and maximum energy capacity. Based on the theoretical framework, the energy budget of young adults to cope with thermal stress was set as three times higher than for the elderly. This framework was used to quantify the contribution of direct solar radiation to energy balance and then classify walkability during clear-sky summer hours; the term 'walkable' referred to environmental conditions allowing users to walk without feeling exhausted. The methodology was tested on an open area and an urban canyon in Milan; applicability by urban designers was key in developing a simplified way to evaluate shading needs. This approach could be applied to evaluate solar radiation exposure of pedestrian paths adopting diverse user experiences as an evaluation criterion.


Assuntos
Pedestres , Exposição à Radiação , Luz Solar , Idoso , Humanos , Adulto Jovem , Estações do Ano , Caminhada
14.
J Arthroplasty ; 39(3): 569-572, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37926221

RESUMO

BACKGROUND: Women orthopaedic surgeons face unique challenges during their careers. There are extremely low numbers of women in the field, particularly in the specialty of adult reconstruction. Factors contributing to low numbers of women entering this subspecialty include increased perceived physical demand relative to other fields, occupational hazards during pregnancy such as exposure to radiation and polymethylmethacrylate bone cement, concerns for work-life balance, and limited number of women within the subspecialty. The following editorial provides a framework to understand and manage the potential occupational hazards to pregnant and lactating surgeons, parental leave, and postpartum return to work. We aim to dispel any unfounded myths and provide evidence-based education that may help overcome these barriers. In doing so, we hope to encourage more women to consider adult reconstruction as a potential career. METHODS: Our primary method consisted of completing an extensive literature review on the past and current articles about the aforementioned barriers which may contribute to the low number of women entering adult reconstruction. After this literature search was completed, we composed a comprehensive editorial that provided evidence-based education and recommendations for medical professionals. CONCLUSIONS: Issues pertaining to parenthood, pregnancy, and lactation pose barriers to success for women in orthopedic surgery. These concerns may dissuade talented women from pursuing a rewarding career in adult reconstruction. Education on these issues is needed to help our early-career colleagues plan and care for their families. Clearly stated and published policies should be made available in all training programs, fellowships, and clinical practices to allow understanding and unbiased implementation. By being more inclusive, adult reconstruction will have access to the best possible surgeons, which will benefit not only patients but the field as a whole.


Assuntos
Cirurgiões Ortopédicos , Ortopedia , Gravidez , Adulto , Humanos , Feminino , Lactação , Ortopedia/educação , Artroplastia
15.
Acta Odontol Scand ; 82(1): 66-73, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38058132

RESUMO

OBJECTIVE: Indication-specific optimum field-of-views (FOVs) have been assessed for CBCT scans of impacted maxillary canines and mandibular third molars, as 40∅ × 35 mm and 35∅ × 35 mm, respectively. The objective was to investigate possible changes in absorbed organs and effective doses, for these two imaging indications, performing CBCT examinations with optimum FOV sizes instead of commonly used FOVs. Additionally, radiation exposure-induced cancer risk was calculated for both imaging indications with optimum FOVs. METHODS: An adult female head phantom (ATOM 702-D, CIRS, Norfolk, VA, USA) was scanned using Planmeca Viso G7 CBCT-device (Planmeca, Helsinki, Finland). Scanning factors, different FOV sizes, dose-area product (DAP) values and anatomical FOV locations were used for Monte Carlo PCXMC-simulation and ImpactMC software. In the PCXMC- simulation, 10-year-old child and 30-year-old adult phantoms were used to estimating effective and absorbed organ doses. RESULTS: The effective dose varied from 58 µSv to 284 µSv for impacted maxillary canines, and from 38 µSv to 122 µSv for mandibular third molars, the lowest dose value for each corresponding to optimum FOV. Effective dose reduction between the optimum FOV and the smallest common FOV of 50∅ × 50 mm, maintaining other scanning factors constant, was 33% for impacted maxillary canines, and 45% for mandibular third molars. At all examinations, the highest absorbed organ doses were in salivary glands or in oral mucosa. CONCLUSIONS: Optimum FOVs, 40∅ × 35 mm for impacted maxillary canine and 35∅ × 35 mm for mandibular third molar, could decrease effective doses received by young patients, and improve radiation safety in these common CBCT imaging procedures.


Assuntos
Exposição à Radiação , Tomografia Computadorizada de Feixe Cônico Espiral , Dente Impactado , Criança , Adulto , Humanos , Feminino , Doses de Radiação , Dente Serotino/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Dente Impactado/diagnóstico por imagem
16.
Int Orthop ; 48(8): 2137-2143, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38589709

RESUMO

PURPOSE: Third and fourth-generation minimal invasive osteotomies (MIO) for the treatment of hallux valgus (HV) have become popular procedures worldwide with promising results due to the improvement in the fixation method. The tricortical cannulated screw placement remains a complex procedure that is technically challenging and requires a long skill learning curve with high radiation exposure mainly in the form of intensifier shots (IS) required for the MIO fixation. This study aims to compare the number of X-ray IS required using three different techniques for the cannulated guide placement. METHODS: A retrospective cross-sectional observational and comparative study was conducted to assess the number of X-rays IS required for correct cannulated screw guide placement using three different techniques: traditional perforator, the drill and joystick, and K-wire first techniques. RESULTS: A total of 53 MIS procedures from thirty-one patients in two different hospitals were included. IS X-rays were 155.1 ± 29.7 in the traditional technique (n = 14), 143.0 ± 43.2 in the drill and joystick technique (n = 22), and 85 ± 18.7 in the K-wires first technique (n = 17), p = < 0.001 using one-way ANOVA. CONCLUSIONS: The K-wire first technique statistically significantly decreases X-ray IS numbers p ≤ 0.001. There were no statistically significant differences between the traditional (after osteotomy K-wire placement) and the drill and joystick techniques (p = 0.36).


Assuntos
Parafusos Ósseos , Hallux Valgus , Procedimentos Cirúrgicos Minimamente Invasivos , Osteotomia , Humanos , Hallux Valgus/cirurgia , Hallux Valgus/diagnóstico por imagem , Osteotomia/métodos , Osteotomia/efeitos adversos , Osteotomia/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Retrospectivos , Estudos Transversais , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Fios Ortopédicos , Idoso , Radiografia/métodos , Resultado do Tratamento
17.
J Neuroradiol ; 51(2): 210-213, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37499791

RESUMO

We propose a modified dynamic CT-myelography technique for patients with fast CSF leaks caused by ventral dural tears in order to reduce radiation exposure and complications. A fluoroscopy-guided lumbar puncture using an epidural anesthesia kit replaces a CT-guided lumbar puncture, and a smaller volume of less concentrated contrast media is used. This approach has advantages, including speeding up the procedure, reduced radiation exposure, and elimination of the risk of contrast injection into the epidural space.


Assuntos
Hipotensão Intracraniana , Humanos , Hipotensão Intracraniana/diagnóstico por imagem , Hipotensão Intracraniana/complicações , Vazamento de Líquido Cefalorraquidiano/complicações , Vazamento de Líquido Cefalorraquidiano/diagnóstico , Mielografia/efeitos adversos , Mielografia/métodos , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia/efeitos adversos
18.
J Radiol Prot ; 44(2)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38754384

RESUMO

To address points arising from the recent study of nuclear workers in the USA and the International Nuclear Workers Study (INWORKS), concerning the difference in solid cancer risk estimates between those first hired in earlier and later calendar years, subsidiary analyses were conducted on a cohort of 172 452 workers in the National Registry for Radiation Workers (NRRW) from the UK. A total of 18 310 incident first primary solid cancer cases were registered in the period from 1955 until 2011 in the NRRW cohort and workers accrued 5.25 million person-years of follow-up. Incidences rates of all solid cancers combined, lung cancer and solid cancer excluding lung cancer were examined in terms of external radiation doses in the full cohort and in a sub-cohort of workers who had no record of internal exposure monitoring and were defined by the periods of first hire before and after the beginning of the years 1960, 1965 and 1970. All analyses were carried out using Poisson Regression. These analyses demonstrated that only for lung cancer between the pre-1965 and post-1964 periods is there strong evidence for a difference in the risks using the NRRW full cohort. In the other calendar period breakdowns and for the other cancer groups, there is no clear evidence of differences in the risks. The NRRW estimation of risks between recent and early workers is not generally consistent with the US workers cohort or the INWORKS evaluations that later hired workers are at much higher solid cancer risk than earlier hired workers, although INWORKS contains a significant part of the latest updated NRRW cohort as well as the US data. The conclusion that the INWORKS and US study data demonstrate a real difference in excess solid cancer risk from external radiation exposure between earlier and later workers is premature. The results presented here should also be treated with caution because of the limited corroborating evidence from other published studies. Information on internal doses, neutron doses as well as non-radiation factors such as smoking and asbestos exposure would be needed to make definitive inferences.


Assuntos
Neoplasias Induzidas por Radiação , Doenças Profissionais , Exposição Ocupacional , Humanos , Reino Unido/epidemiologia , Neoplasias Induzidas por Radiação/epidemiologia , Incidência , Exposição Ocupacional/história , Masculino , Doenças Profissionais/epidemiologia , Doenças Profissionais/história , Feminino , Pessoa de Meia-Idade , Adulto , Neoplasias/epidemiologia , Sistema de Registros , Neoplasias Pulmonares/epidemiologia
19.
J Radiol Prot ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39142297

RESUMO

The Western Australian mining industry is a global supplier of critical minerals, including lithium and rare earths. The lithology of these minerals is associated with elevated concentrations of naturally occurring radionuclides (NORs). An increase in the number of mines producing the minerals has witnessed a commensurate increase in the number of workers potentially exposed to the radiation from NORs. The regulatory framework in Western Australia underwent significant change in March 2022. Mining operations whose workers are likely to receive doses greater than one mSvy-1 are referenced as relevant mines and are required to submit an annual report of worker doses to the mining regulator. This research provides an overview of the new legislative framework and updates the information in Ralph and Cattani (2022) to include data derived from annual radiation doses reported by relevant mines in the period spanning 2020-21 to 2022-23. In 2022-23, 38 mining operations were identified as relevant mines, an increase of sixteen from 2020-21. The mean effective dose (ED) reported in the three-year period was 1.0 mSv, and the maximum ED was 4.9 mSv. The collective effective dose of the mine worker population reached an historical maximum of 2,339 man.mSv in 2022-23. Inhalation of long-lived alpha emitting radionuclides in dust remains the most significant contributor to worker doses. Inhalation of radon-22, radon-220 and their short-lived progeny, once considered as a negligible contributor to worker doses, is the second most significant exposure pathway. A declining trend in the number of samples collected per worker is highlighted as requiring remediation to provide confidence in the reported dose estimates. The transition to the new legislative framework for radiation protection in mines has been supported by the publication of guidance materials which have been widely endorsed by the industry. .

20.
J Radiol Prot ; 44(1)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38295404

RESUMO

Radioactive seed localization (RSL) provides a precise and efficient method for removing non-palpable breast lesions. It has proven to be a valuable addition to breast surgery, improving perioperative logistics and patient satisfaction. This retrospective review examines the lessons learned from a high-volume cancer center's RSL program after 10 years of practice and over 25 000 cases. We provide an updated model for assessing the patient's radiation dose from RSL seed implantation and demonstrate the safety of RSL to staff members. Additionally, we emphasize the importance of various aspects of presurgical evaluation, surgical techniques, post-surgical management, and regulatory compliance for a successful RSL program. Notably, the program has reduced radiation exposure for patients and medical staff.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/métodos , Radioisótopos do Iodo , Mama , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA